PortStore2 PL. RS Ethernet converter + serial buffer TCP/IP Server or Client/Server mode EN
|
|
|
- Lizbeth Parks
- 9 years ago
- Views:
Transcription
1 PortStore2 PL RS Ethernet converter + serial buffer TCP/IP Server or Client/Server mode EN
2 strana 2 z 12 October 2007 page 2
3 Table of contents Table of contents... 2 Table of contents... 3 Basic features... 4 Technical parameters... 5 CONNECTORS DESCRIPTION... 6 Connector wiring... 6 QUICK SETUP... 7 Cable connection... 7 IP address configuration... 7 Did you not find the MAC address of the device in the list?... 7 Configuration using TCP Setup (recomended)... 8 Configuration using RS-232 terminal... 9 System topology HW VSP - VIRTUAL SERIAL PORT Using HW VSP with PortStore HW VSP settings Factory defaults Network parameters Practical examples of the configuration x PortStore2 devices connected to each other Configuration of the device - FAQ Free application software PORTSTORE2 IN PRACTICE Application hints Use TCP port numbers above Security Network Virtual Terminal Extension of the connection timeout Typical applications Application examples BASIC TYPES OF COMMUNICATION Ordering number Related accessory strana 3 z 12 October 2007 page 3
4 PortStore2 RS-232- CDR/SMDR PBX accounting data buffer Converter of the RS-232 serial line to Ethernet and back at TCP/IP protocols and UDP/IP with 2048 kb of a flash memory for data storage from the serial port for the case of the inaccessibility of the TCP connection. Software for retrieving data from a buffer available. Built-in Virtual Serial Port support. Basic features One RS-232 serial port accessible via Ethernet (TCP/IP or UCP/IP) The serial port incoming data are stored to a 2048kB buffer memory. When a TCP connection is established the data is sent as a RAW TCP stream data flow. The device can work in TCP Client or TCP Client/Server mode PortStore2 can be used for storing RS-232 incoming data as well as for remote serial port access over Ethernet network. Remote port can be controlled by a Virtual driver for Windows such as COM 5 (driver for Windows 2000/XP is free) compatible with RFC ways of the device s configuration: o Locally over RS232 (serial terminal); o TCP/IP terminal access at TCP port 99; o Using simple Windows program (UDP Broadcast). Data safety solved with: o Predefined range of IP addresses and ports which have granted access to the device. o TCP connection can be authorized with 128 bit signature with TEA algorithm. Versatility of the serial interface. Communication speed adjustable in the range of Bd, Handshake (CTS/RTS, Xon/Xoff, none). Programming libraries for the MS Visual Basic, Delphi, Borland C++, JAVA, PHP and other routines PS Eye software for regular buffer reading available. It can work as an NT service under Windows NT technology. Available as an executable file or as a source code (Borland C++). strana 4 z 12 October 2007 page 4
5 Technical parameters Serial port RS Data bits 7 or 8 or 9 + Stop bits, Parity 1 or 2, None / Odd / Even / Mark / Space parity + Baud rates kbd entire range, step = 50 Bd + Data flow control Xon/Xoff, CTS/RTS, None + Interface 1x DB9M (RxD,TxD,RTS,CTS,GND) + Used RS-232 signals RxD,TxD,RTS,CTS, (DTR output defined voltage level only) + Remote RS-232 parameters settings RFC2217 with using NVT over TCP/IP stream if NVT enabled + Virtual Serial Port SW HW VSP available for OS: Windows 98, 2000, XP, NT 4.0 Buffer memory + RS-232 Buffer memory kb Flash for incoming serial data + Buffer overflow signaling + Buffer type Linear FIFO data space Network: None RS-232: HW or SW handshake if buffer is full + Buffer data readout format RAW binary TCP/IP stream / RepBuf protocol (see SDK for details) Ethernet port + Interface RJ45 (10BASE-T) 10 Mbit or 10/100 Mbit network compatible only! + Compatibility Ethernet: Version 2.0/IEEE Supported protocols IP: ARP, UDP, TCP + NVT (Network Virtual Terminal) + Supported TCP/IP modes TCP Server, TCP Client/Server + TCP connection close timeout timeout 50s (with enabled NVT can be prolonged by ACK/NOP) Environment + Temperature range Operating: C Storage: -10 to 85 C + Humidity (non-condensing) 5 to 95 % Physical parameters + Power supply requirements + Power battery backup 8-24V / Max. current consumption 200 ma DC - barrel (coaxial) power connector, GND on the shield + Dimensions 28 x 105 x 135 [mm] (H x W x D) + Weight 395 g Functional parameters The Flash buffer power failure backup operated by internal battery, have to be charged by power on for 96 hours minimally. Device SETUP configuration options Diagnostic LEDs - RS-232 Setup over any RS-232 terminal with DIP1=ON Independent settings:9600 Bd, 8N1, No handshaking - TCP/IP Setup - using any telnet terminal on the TCP/IP 99 port - Hercules SETUP utility via UDP (basic network parameters only) - Power (green) - Link & Activity (yellow) - Rx / Tx serial port activity (green / red) strana 5 z 12 October 2007 page 5
6 Connectors description RS-232 serial interfaces are connected to the Cannon DB9M connector. You can switch between them using DIP3 (only one can be active at a time). Signalization: Power/Status - green External power supply/status LINK - yellow LINK & Ethernet Activity RxD/TxD -green/red receiving/sending Data Connector wiring Ethernet : Power Power supply: LINK Pin PortStore2 Port Signal 1 <> 2 <- IN RxD 3 -> OUT TxD 4 -> DTR 5 -- GND 6 <- IN DSR 7 -> OUT RTS 8 <- IN CTS 9 <> Cannon 9 - Male Standard IBM PC RS-232 Port Pin Signal 1 <- CD CD 2 <- RxD 3 -> TxD 4 -> DTR 5 -- GND 6 <- DSR 7 -> RTS 8 <- CTS 9 <- RI Cannon 9 - Male DC 9..15V / max. 0.3 A Link activity LED Power/Status LED RS-232 LED RxD/ TxD Power 9-12V Ethernet RS-232 Push button Power/Status LED RS-232 LED Lights device operating Green Light receiving Data Slow blinking device booting Red Light - sending Data Quick blinking device in RS-232 Setup Push Button - Push button for circa 3 seconds RS-232 Setup - Push for more than 20 seconds (until Power/Status LED stop blinking for 3 seconds) Restore default configuration Access to RS-232 Setup - Push and hold button and connect power supply - When Power/Status LED starts quickly flashing, release the button - RS-232 LED blinks once red and RS-232 Setup is active strana 6 z 12 October 2007 page 6
7 Quick SETUP In this chapter you will be shown the way of configuration within 5 minutes. If you experience any problems, please, read the following chapter which describes the setup process step-by-step. Cable connection Connect the delivered feeding adaptor. Connect PortStore2 into the Ethernet 10/100 Mbit network. Plug the connector of the power adaptor into Portstore2 s power connector. The green Power indicator will light up. The LINK indicator will light up and go down as the data transfer to the Ethernet fluctuates (Activity signalization). IP address configuration Run the application HerculesSetup.exe which can be found in the root directory of the delivered CD or at In the UDP Setup bookmark click on Find modules and in the left column the MAC address of the device should appear. Click on the MAC address and set the required parameters (at least IP address, Mask and Gateway). Make sure you have the Enable TCP Setup field checked and by clicking the Set module save these parameters to the device. Now that you have set the IP address and other device s parameters it is possible to work on. Did you not find the MAC address of the device in the list? If the LINK indicator did not light up or the device does not respond see the following possibilities. - Does your Ethernet network support 10 Mbit devices? - Is the proper TP cable used (TP Patch cable for the connection to the switch crossed for PC connection). - Are you using crossed TP cable directly from your notebook to the device? Please disable DHCP and define any fixed IP address (IP= , MASK= for example). Without DHCP server isn t declared DHCP network setting. - Check your power adaptor and if the Power indicator lights. strana 7 z 12 October 2007 page 7
8 Configuration using TCP Setup (recomended) Switch to the TCP Client bookmark and insert the configured IP address. As a TCP port number insert the port number 99. Click on the Connect button and the prompt WEB51> will appear in the list on the left. Click into this field and press ENTER. Actual parameter configuration will be written up in the window. Configuration of parameters itself is called by typing the letter of the corresponding option and its value. (e.g. I for an IP configuration of the device s address). Information on commands can be displayed by execution of the sequence: command + question mark and <Enter> I? <Enter>. All settings are detailed further in the text. After setting the parameters call the R command for Reboot and then click the Disconnect button. strana 8 z 12 October 2007 page 8
9 Configuration using RS-232 terminal RS-232 serial setup is recommended for Flash initialization, it can be done via Hercules utility, the Serial tab. If you don t have Windows or our Hercules program at hand, you can configure the device from any RS-232 terminal. 1. Switch off the power supply (disconnect the power adaptor plug). 2. Connect the cable to the RS-232 (Port 1) via supplied LapLink cable for PC. 3. Open your favorite terminal program (e.g. HyperTerminal), set the required serial port and choose parameters N1. Link activity LED Power/Status LED RS-232 LED RxD/ TxD Power 9-12V Ethernet RS-232 Push button 4. Use the nail or paper-clip, press and Hold the Push button. 5. Switch on power (connect the Power Supply), while holding the Push button. 6. The green Power/status LED indicator will slow blinking = wait, hold the Push button. 7. When green Power/Status LED Fast blinking, drop the Push button. 8. If the RS-232 LED blink Red, the RS-232 Setup mode is activated, when not repeat again from step You can see a text menu for device s configuration in the terminal program. 10. Continue setup the device, as previously described. 11. If you wish to use the buffer for incoming data on the serial port, it s necessary to initialize the buffer. 12. After setting device s parameters, just switch Power Off. The RS-232 Setup mode have to be activated again with using the Push button. strana 9 z 12 October 2007 page 9
10 System topology Here you can see the typical PortStore2 connection and the basic network protocols. TCP/IP Server mode [Client -> Server] PortStore2 waits as a TCP server until any side (PC or server) opens a TCP connection. When the connection is established, the internal buffered data are sent and then the device allows communication as a standard "terminal server". TCP/IP Client mode [Server <- Client] PortStore2 received serial port data into its internal buffer and tries to send them to the server. It will try to open a connection to the preset IP address and port. If the attempt is unsuccessful, it will wait for a second in the TCP Server mode and then try to open the connection again. UDP/IP The data is transferred in UDP packets with no delivery notification. VSP (Virtual Serial Port) You have a HW Virtual Serial Port software which creates a virtual COM port under Windows OS so that the device acts like it s connected directly to your PC, though it s a virtual remote port. If the buffer is enabled and the TCP connection is not available, the data is stored into the internal buffer memory. For the full function it s advantageous to enable NVT (Network Virtual Terminal), so the port would be RFC2217 compatible. October 2007 page 10 strana 10 z 12
11 HW VSP - Virtual Serial Port Virtual driver of the serial port for Windows is a software instrument that adds a virtual serial port (e.g. COM5) to the operating system and redirects data from this port to other hardware port. Nowadays the virtual port is mainly used for connection of the RS-232 serial port via USB or Ethernet network. Runs under Windows 2000 and Win XP. If the device supports RFC 2217 (NVT) you can set parameters of the remote serial port (baud rate, parity, stop bits). Debugging is eased by the possibility of a recording the communication into a LOG file. It is possible to create more Virtual Serial Ports on a single computer (COM5, COM6, COM7...) by running VSP.EXE via command line. Using HW VSP with PortStore2 Install HW VSP (directory HW_VirtualSerialPort on our CD). Check that NVT is enabled (on the UDP Setup tab from Hercules utility). If not, enable NVT and save the configuration. Run HW VSP and search for the PortStore2 in the UDP bookmark. Choose the MAC address of the device and click on the Use this IP button. Switch to the Virtual SP bookmark. The IP and Port should be already set. This searching via UDP Broadcast works only on a local network. If you have the PortStore2 installed somewhere behind the router or similar component you have to set the IP address and Port manually in the Virtual SP tab. Choose the serial port you want to create (COM1 COM20) and click the Create COM button. The frame LAN status will show whether the device has been found and if correct, the virtual serial port is created. As you run any application which opens selected virtual port (here it s COM5) the HW VSP will link up with PortStore2, set the remote port according to the opened serial port (speed, parity, number of bits, handshake) and starts to transfer data. Some applications have problems with serial port numbers higher than COM4 but you can use the original Hyperterminal from Windows, Serial tab from the Hercules setup utility or Slovene program Terminal.exe. These programs are located in the utils directory of our CD. October 2007 page 11 strana 11 z 12
12 HW VSP settings TEA Key frame You can use the TEA algorithm to secure the TCP/IP access (you must set the same TEA key on both sides of the communication). NVT frame Enables the RFC2217 detection of our remote ports. Do not forget to turn on NVT support on the remote device. NVT filter filters NVT commands from the data flow. NVT port setup sends commands to the remote port according to the VSP settings in your PC. If your terminal program (e.g. HyperTerminal) changes data transfer speed to Bd and this function is enabled, the VSP driver sends NVT command (according to RFC2217) to change the remote TCP/IP port s speed as well. Keep Connection keeps the TCP/IP connection opened even after 50 seconds of inactivity. HW VSP parameters log. enabled VSP driver creates file "C:\serialport.log" for logging all activity of the virtual serial port. TCP server mode Activates VSP as a TCP/IP server. Driver then behaves as a TCP Client/Server = side which first receives any data switches to the role of a client and opens the connection. TCP server s port, which is used as input can be configured in main Virtual SP tab and we recommend using numbers higher than Create port on start VSP If checked all virtual port will be created automatically on startup of VSP. If you need to create virtual ports on Windows startup it s necessary to check the box "Start VSP on boot". Hide on startup Hides VSP to system tray. Icon can be then found next to the clock. Don't create port if ping fails IP address of the device is tested before creating virtual port. If testing fails the port is not created. Connect to module if port is closed When checked, you can loose data incoming from remote device, if the virtual serial port isn t used by some application. Start VSP on boot Adds a path to VSP into register RUN (HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\run) in Windows. VSP is then run on Windows startup. HW VSP command line parameters HW VSP can be also started through specific parameters from command line. This way more virtual serial ports can be created at once. Precise description of parameters can be found at Example: CharonVirtualCom.exe -R -i :23 -c5 -S0 -N1 -Nf -Np -H1 October 2007 page 12 strana 12 z 12
13 PortStore2 setup configuration parameters description Detailed description of particular parameters of the device and list of possible parameters follows. Factory defaults Standard configuration, listed here, can be whenever restored by option D0 or D1 from setup, which can be activated as: TCP Setup on TCP port 99 (if enabled), you need to restart the device after any change. RS-232 Setup, which enables using Push button when Startup and works over RS-232 (9600 8N1). *** HW-group.com HW 5.0 SW 2.L #01 *** MAC Address 00:0A:59:XX:XX:XX =========== IP Setup ============ I: Address J: Port 23 M: Mask G: Gateway ===== In IP access filter ====== W: Address N: Mask X: Port 0.0 Y: Port Mask 0.0 == Active (Client/Server) mode == S: Send to IP PASSIVE mode U: Port 4023 T: IP mode TCP V: NetworkVirtualTerminal Off K: Keep connection Off E: Erase buffer on None Press <Enter> to continue ====== Flash Buffer Setup ======= &F: Flash buffer On Press <Enter> to continue ========= Serial Setup ========== &B: Speed 9600 &D: Data bits 8 &P: Parity NONE &V: Variable Parity Off &S: Stop bits 1 &C: Flow Control NONE &R: RS485/RS422 control RTS = On [+8V] &T: Serial Line Timeout 0 - Off &G: Char. Transmit Delay 0 - Off &H: Tx Control Tx FULL duplex ======== Security Setup ========= %A: TCP autorisation Off %K: TEA key 0:01:02:03:04 1:05:06:07:08 2:09:0A:0B:0C 3:0D:0E:0F:10 %S: TCP/IP setup On ============ Other ============ D: Load/Save Settings from/to Flash F: Erase & Init Flash Buffer R: Reboot WEB51> October 2007 page 13 strana 13 z 12
14 Network parameters MAC Address 00:0A:59:00:95:6C MAC address is a unique network device address in the Ethernet and it is always factory-preset. You can find it on the label inside the device. Using this address, the devices can be distinguished for example in the UDP mode of the configuration program. The address respects restoring of the default configuration with the D0 command. I: Address Configuration of the device s IP address. IP address, Mask and Gateway description: Ethernet device communicates: J: Port 23 Configuration of the device's communication port range: Port 99 is used for TCP configuration, if supported by the version and enabled in the setup. M: Mask Configuration of the IP mask for the local network. All IP addresses outside the area delimited by the device's own IP address and this mask will be accessed via the Gateway. On local network segment You don t need a Gateway, but IP addresses of both devices must be in the range allowed by the Mask setting. If you set the Mask to the IP addresses may differ only in the last byte. Outside local network using Gateway (which must be in the range allowed by Mask parameter). You can also restrict the IP address range using the In IP Setup commands. We recommend keeping this parameter on for debugging. G: Gateway Address of the gateway that provides access to outside networks, as defined by the IP address and the mask. ====== In IP Setup ====== W: Address IP address of a network or computer that is allowed to communicate with the device. This value must result from multiplying the remote IP address and the restriction mask (option N), otherwise the device does not react. N: Mask This mask restricts addresses that can communicate with the device. Security can be greatly enhanced by setting a fixed address or a suitable restrictive mask that disallow communication with unauthorized parties. X: Port 0.0 Y: Port Mask 0.0 This restricts TCP ports that can communicate with the Device. (IP requesting access AND N ) = W If this condition is valid, you can access the device (AND is binary multiplication). October 2007 page 14 strana 14 z 12
15 TCP and UDP parameters ====== Out IP Setup ====== S: Send to IP Defines the IP address which will the Device communicate with (useful on large networks) U: Port 23 If the S setting differs from , the device is in the TCP Client/Server mode. This means, that if no TCP/IP connection is esteblished and the device receives serial port data, it switches to UDP mode and port settings If you use the UDP communication, you need to fill in the S parameter. The converter does not initiate the connection so all data are sent to this address and port! the TCP Client mode and periodically tries to initiate a connection. The device is in the TCP Server mode in the meantime between attempts. If you set the S = , you will set the device to the TCP Server mode. T: IP mode TCP Switches between the TCP and UDP protocols. UDP is faster but packets can be lost or delivered out of order. Hence it is suitable for communication only on a local network segment in request-reply mode, usually for converting a RS-485 communication. 0: TCP 1: UDP In the UDP/IP mode you cannot use: - the NVT commands - the TEA algorithm. The Question-answer protocols can be up to 40% faster. V: NetworkVirtualTerminal Off Network Virtual Terminal allows the interpreting of the Telnet protocol sequences including certain RFC2217 extensions, enabling on-the-fly changes of serial port parameters (speed, parity,...). Detailed NVT description can be found on our website. When communicating with the serial port using telnet, e.g. with the TeraTerm program, this option should be turned on. Otherwise, telnet control commands (seen as "junk") intended for configuration negotiation at the beginning of the communication are forwarded to the serial port. If you don't want to use this option, set your client to RAW communication mode. 0: Off (NVT disabled) 1: On (NVT enabled) K: Keep connection Off This option allows keeping the connection alive with sending NOP commands, because TCP automatically closes the connection after 50 seconds of inactivity. NVT must be enabled for this parameter to work. 0: no keep connection (prefered) 1: keep connection E: Erase buffer on Open connection Option for clearing the internal Device buffer whenever a connection is established or closed. This option is useful e.g. if your device periodically says "I'm alive" and you don't want to waste time retrieving these notifications from the buffer. 0: none 1: Close TCP/IP connection 2: Open TCP/IP connection 3: Open & Close TCP/IP connection October 2007 page 15 strana 15 z 12
16 &F: Flash buffer On Activates/deactivates the 2048 kb buffer memory. When the buffer memory is turned off, you are working directly with the serial port, using only the 32 kb RAM in the device. (Only RS-232 Setup) 0: Flash mode Off 1: Flash mode On (RAW mode) 2: Flash mode On (RepBuf mode) Recommendation When installing the device or in case of any problems, use the F: Erase & Init Flash Buffer command after enabling the buffer memory support. Flash init have to be launched from the serial setup mode (via RS-232 terminal). Note: RepBuf is a new protocol for handling with buffered data to the PortStore buffers that enables confirmation of data transport on Ethernet. Serial port parameters ====== Serial Setup ====== &B: Speed 9600 Configuration of the communication speed for the serial line, range Bd, step 50 Bd. To set 9600 Bd enter: &B9600. &D: Data bits 8 Number of data bits for the serial transfer, this must correspond with the stop bit and parity settings. 7: 7 bits 8: 8 bits use &D8. &P: Parity NONE Parity of the serial asynchronous communication. N: none / O: odd / E: even / M: mark / S: space &V: Variable Parity Off Function for the serial 9-bit data transfer. It uses the 0xFE prefix, recommended for box-2-box data transfer. Only a difference from the parity bit s default value is transferred. Off: incorrect parity bit ignored On: incorrect parity bit tranfered to other device &S: Stop bits 2 Number of stop bits for the RS-232 serial line. This respects the rule of 9 bits (max. 10 bits). If you set 7N1, setup will correct this to 7N2, as well as 8E2 will be corrected to 8E1. &C: Flow Control NONE Serial data flow control, if you use data flow control and the input buffer is full, handshake will signalize that the device can no longer accept data. 1: none no control, RTS viz. &R. 2: RTS/CTS RTS/CTS pin control 3: Xon/Xoff SW flow control. October 2007 page 16 strana 16 z 12
17 &R: RS485/RS422 control On [+8V] Defines idle level of the output RTS pin. Important for devices powered from RTS or for add-on RS485 Devices that use RTS to switch direction. Especially for the internal RS485 module, the "HW echo" option should be on. This means that the receiver reads the data back from RS485 and generates hardware echo from the actual RS485 bus. 0: RTS = On [+8V] (recomended for RS-232 or RS-485 mode) 1: RTS = Off [-8V] 2: TxRTS HW echo ON (recomended for RS-485 debug only!) 3: TXRTS HW ECHO OFF (RS-485) &T: Serial Line Timeout 0 Off Specifies how long the Device waits after receiving the last character before wrapping up the data in a packet and transmitting them. The timeout is specified as the number of characters and displayed as the number of chars as well as the time according to the given serial communication speed. If the speed changes, the time is also changed but the number of characters defining the timeout is not (10 characters at 9600 Bd = about 11 ms, or 5.7ms at 19,200 Bd). &G: Char. Transmit Delay 0 Off For controlling units with small RS232 buffer, it is necessary to keep relatively high baud rate but insert delays between individual characters. The delay is defined in milliseconds and it is defined as the time between the starts of individual characters; so, for 2400 Bd a 2ms delay has no effect since the character starts are 2.4 ms apart. &H: Tx Control Tx FULL duplex When HALF duplex is activated, the Device assumes unidirectional medium connected to the serial line (e.g. RS485) and won't start transmitting data while receiving. 0: FULL duplex (RS-232) 1: HALF duplex (RS-485) Other parameters ===== Security Setup ====== %A: TCP autorisation Off Activates TEA authorization - requested from the remote side after the connection is established. 0: TEA authorisation Off 1: TEA authorisation On %K: TEA key 0:01:02:03:04 1:05:06:07:08 2:09:0A:0B:0C 3:0D:0E:0F:10 To set the TEA key use the "%K" option. Set 16 bytes in quadruples using four hexadecimal values separated with colons. The first string defines 0-3rd quadruple of bytes. So, to set the last 4 bytes to the displayed value, use %K 3:0D:0E:0F:10. %S: TCP/IP setup On Allows or denies the remote configuration using TCP setup on port 99. This command works only in the RS-232 Setup mode. 0: TCP Setup disabled 1: TCP Setup enabled (TCP server on the port 99) October 2007 page 17 strana 17 z 12
18 ========= Other ========= F: Erase & Init Flash Buffer Initializes the FLASH buffer. If you are installing a new device, do not forget to initialize the buffer using this command. D: Load/Save Settings from/to Flash Saves the current settings to memory or restores saved settings. R: Reboot Software reset. Recommended when changing TCP Setup parameters. 0: Reloads settings from position 1 1: Reloads settings from position 2 2: Stores settings to position 1 3: Stores settings to position 2 October 2007 page 18 strana 18 z 12
19 UDP/IP mode settings If you select T: IP mode UDP, the device will communicate with the remote side using unacknowledged UDP packets. Also, the following menu appears in the setup. ==== Triggering Setup ===== *L: Trigger Length 1 Number of bytes of the starting and ending packet trigger condition. Allowed values are from 0 to 4. If the lengths of your start and stop triggers differ, use the trigger mask and don't forget to include the masked characters in the lengths - even though they contain actual frame data. *P: Post Trigger Length 0 In some protocols, checksum or other info follows the stop trigger. This value defines the number of characters after the stop trigger that should be included in the packet. If the start and stop triggers are equal, this value specifies packet length without the 0..4 bytes of start trigger. *S: Start Trigger Pattern (The 4 input bytes of data AND *M ) = *S Start trigger for packet transmission. Four bytes are set but only the number of bytes specified in "L: Trigger Length" is considered *X: Stop Trigger Pattern Sets the stop trigger for sending data to the Ethernet. (The 4 input bytes of data AND *Y ) = *X *M: Start Trigger Mask Mask of the start trigger. Masking works similarly to the Ethernet netmasks using a bitwise AND. Value of 255 means that the tested character must be equal to the character specified in "*S: Start Trigger Pattern". For example, to start the transfer with any control ASCII character (0..31d) use for the trigger pattern, for the mask and 1 for the length. If you set both the character and the mask to 0 the trigger activates for any character. Setup example If you need to send all data from the serial line to the opposite side, use: *L: Trigger Length 0 *P: Post Trigger Length 0 *S: Start Trigger Pattern *M: Start Trigger Mask *X: Stop Trigger Pattern *Y: Stop Trigger Mask *E: Max. Start-Stop Length 200 *Y: Stop Trigger Mask Mask of the stop packet trigger for serial line data. For example, the settings displayed here are intended for transferring data in the IntelHEX format over RS485. The start trigger is a colon and the transfer is terminated after receiving the control character <LF> (0Ah = 10d). *E: Max. Start-Stop Length 999 Maximum number of characters sent after the START trigger, if the STOP trigger is not found sooner. After transmission, another START trigger is expected. Essentially, this is a "timeout" specified as the number of characters October 2007 page 19 strana 19 z 12
20 Practical examples of the configuration The following examples show the configuration of parameters essential for typical device applications. 2x PortStore2 devices connected to each other Virtual extension of the serial port over TCP/IP, Bd, 8N1, HW handshake Both devices will try to initiate a connection as a TCP Client when they receive any data. The incoming serial port data will be stored to the internal buffer memory and transferred when a connection is established. When the kb buffer is full the device uses HW handshake to signalize that it can no longer receive data from the serial port. PortStore2 A *** HW-group.com HW 5.0 SW 2.K #01 *** =========== IP Setup ============ I: Address J: Port 4023 M: Mask G: Gateway ===== In IP access filter ====== W: Address N: Mask X: Port 0.0 Y: Port Mask 0.0 == Active (Client/Server) mode == S: Send to IP U: Port 4023 T: IP mode TCP V: NetworkVirtualTerminal On K: Keep connection Off E: Erase buffer on None ====== Flash Buffer Setup ======= &F: Flash buffer On ========= Serial Setup ========== &B: Speed &D: Data bits 8 &P: Parity NONE &V: Variable Parity Off &S: Stop bits 1 &C: Flow Control Xon/Xoff &R: RS485/RS422 control RTS = On [+8V] &T: Serial Line Timeout 0 - Off &G: Char. Transmit Delay 0 - Off &H: Tx Control Tx FULL duplex ======== Security Setup ========= %A: TCP autorisation Off %K: TEA key 0:01:02:03:04 1:05:06:07:08 2:09:0A:0B:0C 3:0D:0E:0F:10 %S: TCP/IP setup On ============ Other ============ D: Load/Save Settings from/to Flash F: Erase & Init Flash Buffer R: Reboot PortStore2 B *** HW-group.com HW 5.0 SW 2.K #01 *** =========== IP Setup ============ I: Address J: Port 4023 M: Mask G: Gateway ===== In IP access filter ====== W: Address N: Mask X: Port 0.0 Y: Port Mask 0.0 == Active (Client/Server) mode == S: Send to IP U: Port 4023 T: IP mode TCP V: NetworkVirtualTerminal On K: Keep connection Off E: Erase buffer on None ====== Flash Buffer Setup ======= &F: Flash buffer On ========= Serial Setup ========== &B: Speed &D: Data bits 8 &P: Parity NONE &V: Variable Parity Off &S: Stop bits 1 &C: Flow Control Xon/Xoff &R: RS485/RS422 control RTS = On [+8V] &T: Serial Line Timeout 0 - Off &G: Char. Transmit Delay 0 - Off &H: Tx Control Tx FULL duplex ======== Security Setup ========= %A: TCP autorisation Off %K: TEA key 0:01:02:03:04 1:05:06:07:08 2:09:0A:0B:0C 3:0D:0E:0F:10 %S: TCP/IP setup On ============ Other ============ D: Load/Save Settings from/to Flash F: Erase & Init Flash Buffer R: Reboot If you want to permit only one address which the device would communicate with, set N: and W:IP address of the other device If you want to rise the security level, disable on both devices TCP Setup on port 99 %S0 = %S: TCP/IP setup Off If you need to improve the security level and allow PortStore2 A to communicate only within local network segment ((0 to 255 at the end of IP address)) use following setting. I: Address M: Mask ===== In IP access filter ====== W: Address N: Mask S: Send to IP I: Address M: Mask ===== In IP access filter ====== W: Address N: Mask S: Send to IP October 2007 page 20 strana 20 z 12
21 Configuration of the device - FAQ Ethernet has stopped working but the LINK LED is lit. Check if the device isn t in the RS-232 Setup mode, which is turned on by Push button? If the device is in this mode the Ethernet part does not respond. Reboot the device by disconnecting of the power supply for at least 3 seconds. The RS-485 communication does not work Check if you have connected the Termination resistors ( ohms) to the line or connector. If you are using a RS485 conversion, set the configuration to &R3 and do not forget to turn the HALF DUPLEX on with setting &H1. I need to power another RS-232 device If you do not need to regulate the data flow (HW handshake) and at the same time need a supply voltage for the device on serial port (up to 5-10 ma) power your application from the RTS output (pin 7 on RS-232 connector). Voltage of circa +8V to +12V can be activated on this pin by &R0 option in the reset mode (&R: RS485/RS422 control). I have problems with HW handshake Some of the RS-232 cables sold as LapLink cables do not support HW handshaking (for connection see picture) when the buffer is full. If you need the HW handshake in your application, make sure your cable does not have pins 7 and 8 connected like shown on the picture. To use HW handshake properly, pins 7 and 8 must be cross-connected like pins 2,3. Wrong RS-232 cable wiring. Free application software Use supplied free software for configuration or as an inspiration for driver writing. Detailed description of free routines, TEA coding and our NVT implementation can be found on our webpage. Borland C++ Delphi Charon 1 communication and NVT example - (TCP Client). Delphi TCP/IP logger/server example - (TCP Server). Delphi TCP/IP and NVT communication example (TCP Client). JAVA TCP/IP NVT communication example (TCP Client). PHP TCP/IP NVT communication example (TCP Client). Visual Basic TCP/IP and NVT (TCP Client) communication example. October 2007 page 21 strana 21 z 12
22 PortStore2 in practice Some practical advices as well as typical application descriptions. Application hints 2048 kb buffer Don t forget to enable the cache memory &F1 after buffer configuration and then initialize it by F command. Without this only the 32kB internal RAM is active. Use TCP port numbers above 1024 If you are using MS Windows and your PC is a TCP Server (with PortStore2 as a TCP Client), try to open connection on ports with numbers above Ports with lower numbers are sometimes reserved for system services and so your application may malfunction. Security For increasing the security of data transfer in TCP mode it s possible to authorize both sides on establishing any TCP/IP connection via TEA 128 algorithm with symmetric signature. The configured password of both sides then won t go through the network. This option is possible only for TCP/IP connection. UDP mode is designed only for local networks. Detailed description of TEA can be found in the handbook Programming of Ethernet Applications on our website. Network Virtual Terminal Learn how to use Network Virtual Terminal in your application. Basically the NVT is a system on which TELNET protocol works. It s simple and transparent way of handing down the setup information which is compatible with all sorts of RFC and above all with RFC2217 for remote control of serial port. Using RFC2217 in examples Setting and changing the serial port speed Using simple binary sequences which are sent in the TCP/IP data flow: FF FA 2C FF F0 (Hex) asks for the actual serial port speed. FF FA 2C FF F0 (Hex) sets serial port speed to 9600 bauds. (25 80 hex = 9600 decadical). Remote device identification With sending the FF F6 (Hex) sequence you ask for the Are You There device identification where the device returns its identification including the firmware version and serial number (MAC address). Extension of the connection timeout Since the device supports only one connection at the moment it s necessary to secure the timeout for this connection. Standard limit after which the connection is terminated in case of no data flow is 50s. It is possible to enable option K: Keep connection which, in 10-second intervals, sends the NOP command into the open NVT connection. October 2007 page 22 strana 22 z 12
23 Typical applications The typical application of the PortStore2 device is a remote access to a RS-232 technology. In case there is no TCP connection available the device stores the incoming serial port data to the internal Flash 2.048kB buffer memory. If the Portstore2 device is in the TCP Client mode, it tries to initialize the connection and send the data stored in the internal buffer. The data is stored in a "RAW" format in the delivered order. The device acts as standard terminal server with a remote serial port access. Application examples PBX systems collecting pricing data from PBX A phone branch exchange can commonly provide pricing information data, which needs to be analyzed using a special software. The PBX sends the data to the RS-232 serial port, but mostly does not have enough buffer memory to store the data in case the receiving device is not working. PortStore2 then receives this data on the RS-232 serial line, stores it in the internal buffer memory, so it can be occasionally downloaded via Ethernet using a special software. In many cases, the server downloading data is in the company s central office and the branches are spread all over the country, connected only using Ethernet network. The buffer capacity is enough to hold typical lines. Serial printer data storage The security central writes all the security information on the serial printer, so the data can be archived. This printer must of course be maintained by authorized personnel and the data is not available in electronic format. PortStore2 can store this data in its internal Flash memory, so the data can be downloaded from the company s office. The buffer capacity is enough to hold typical lines. Card readers, RFID Exchange displays Security alarms Attendance systems UPS control and logging Data recording CNC machines Bar code readers October 2007 page 23 strana 23 z 12
24 Basic types of communication A brief description of basic terms. Detailed version with dictionary of abbreviations (and more) can be found on our website in the Support and download section. TCP server (Passive mode) After turning the device on, it awaits client s connection. When the client is connected the data are sent from Ethernet to serial line and vice versa. If the client isn t connected and there is data incoming from the serial line, they are saved into cache memory (it s size can be configured) and sent as soon as the connection is created (if you haven t chose the function from SETUP for clearing the buffer after client s connection). TCP client (Active mode) The device behaves similarly to the previous case (keeps the server function) but if any data from serial line are transmitted, it has preconfigured the IP address of the opposite side and tries to establish a connection as a client and transfer the data. If it doesn t succeed the data are stored to the buffer memory and transferred with next created connection no matter what the role of the device is (client or server). UDP Data from Ethernet are sent to the preset address and if they come from the serial line RS232, a packet is created and sent to the configured IP address. At UDP the response from other side is not tested, the application itself should be secured from loosing data. Advantage is a little shorter response time which can be practically used especially for RS-485 lines. NVT (Network Virtual Terminal) When using TCP/IP communication the functions of the converter can be extended via NVT by RFC2217 with controlling dataflow which can for example change the speed of a remote serial port, control inputs and outputs or delete the buffer. These controlling commands are added to the data flow and introduced by prefix figure FF whose appearance in the data flow has to be handled by duplication. Detailed description of the NVT can be found in the handbook Programming of Ethernet Applications (which also describes supplied free routines for communication) or in a separate article on our website. VSP (Virtual Serial Port) The device is in TCP Server mode and the PC acts as a TCP Client. You have a HW Virtual Serial Port software which creates a virtual COM port under Windows OS, so that the device acts like it s connected directly to your PC, though it s a virtual remote port. If the buffer is enabled and the TCP connection is not available, the data are stored into the internal buffer memory and sent when a TCP connection is established. If you are using any kind of channel (for example GPRS), it is more useful to initiate a connection on the device s side, so you pay only for transmitted packets. The device can be configured as a TCP Client/Server and the HW VSP can be switched to the TCP Server mode. The connection is then initialized when there is any data coming to the serial port. October 2007 page 24 strana 24 z 12
25 Mechanical parameters Sturdy plastic enclosure intended for wall attachment, setting on a flat surface or installation to a DIN molding (see ordering number). October 2007 page 25 strana 25 z 12
26 OID (Ordering ID) Ordering number Products PortStore2 PL PortStore2 PL unit, without any accessory PortStore2 PL set Recommended starting set contains: - PortStore2 [600298] - EU [600080] or USA [600081] or UK [600082] Power adaptor - DB9 LapLink cable 2m [600063] - Manual, CD Related accessory DB9 Prolong cable 2m [ ] Extension cable Canon 9 connected 1:1, length 2 m. DB9 LapLink cable 2m [ ] Communication cable RS-232 LapLink for PC connection. Wall Plug Power Adaptor Euro version - [ ] US version - [ ] UK version - [ ] Euro Cable plug version (no power cable included) - [ ] October 2007 page 26 strana 26 z 12
IP Relay 2x Relay controlled over Ethernet + RS-232 / Ethernet converter (Terminal server)
IP Relay 2x Relay controlled over Ethernet + RS-232 / Ethernet converter (Terminal server) EN 900 478a Shipment contents Complete shipment of the IP Relay contains following items: IP Relay in a metal
RS232/485 - ETHERNET Converter
RS232/485 - ETHERNET Converter The complete shipment contains Closed converter box with a unique preset MAC address. RS232 interconnection cable (serial port extension cord, Cannon 9-1:1) Propojovací kabel
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
LS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
IP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
TRP-C31M MODBUS TCP to RTU/ASCII Gateway
TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
MODBUS TCP to RTU/ASCII Gateway
MODBUS TCP to RTU/ASCII Gateway Users Manual Model MODport-101, MODport-102, MODport-104 July 2011 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
EZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4
INDEX WHQL Certification Approval...2 User Interface....3 SUNIX s COMLab..4 1.0 Introduction...5 2.0 Specification..5 2.1 Features 2.2 Universal Serial PCI Card 2.3 RS-232 Specification 2.4 Low Profile
RS-232/422/485, Power over Ethernet
IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware
CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program
CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1, 4 2014
WRE6505 Wireless AC750 Range Extender Version 1.00 Edition 1, 4 2014 2.4G 5G Quick Start Guide User s Guide Default Login Details LAN IP Address 192.168.1.2 User Name admin www.zyxel.com Password 1234
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series
TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
RS-232 Communications Using BobCAD-CAM. RS-232 Introduction
RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running
LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION
RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
LBNP16312. RS-232/485/422 serial device server. User manual
Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3
WUA-0605 300Mbps Wireless USB Network Adapter
WUA-0605 300Mbps Wireless USB Network Adapter User Manual V1.0 Certification FCC CE FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
2012 uptimedevices.com
2012 uptimedevices.com Contents Product Overview...3 Installation...4 Web Interface Orientation...5 Web Interface (Login Screen)...6 Summary Screen...7 Sensors Screen...8 Sensor Names...9 Graph...10 Alerts
Operation Manual of EX-9132C-2. Serial to TCP/IP Converter
Operation Manual of EX-9132C-2 Serial to TCP/IP Converter Version 1.2.1 20th May 2013 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features 6 Product Specifications
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
Poseidon2 3268 MANUAL
Poseidon2 3268 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied
Serial over Ethernet Device Server. User s Manual
Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw [email protected] Serial over Ethernet
LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
Wireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
IP WatchDog Lite Dual monitor of Ethernet devices with automatic reset function
IP WatchDog Lite Dual monitor of Ethernet devices with automatic reset function EN 600 218 Shipment contents Complete shipment of IP Watchdog Lite contains following items: IP Watchdog Lite in a plastic
Serial Over IP Ethernet Device Server
NETRS2321E NETRS2321EEU NETRS2321EGB Instruction Manual Serial Over IP Ethernet Device Server 1 Port RS-232/422/485 Serial over IP Ethernet Device Server Manual Revision:10/13/2010 For the most up-to-date
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
32 Transferring Projects and Data
32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1
USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16
RS232 Serial TO Ethernet convert Module USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16 Jinan USR Technology Co., Ltd. works on LAN and WAN and wireless for MCU to Ethernet Solutions, Ethernet,
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Prestige 623R-T. Quick Start Guide. ADSL Dual-link Router. Version 3.40
Prestige 623R-T ADSL Dual-link Router Quick Start Guide Version 3.40 February 2004 Introducing the Prestige The Prestige 623R-T ADSL Dual-link Router is the ideal all-in-one device for small networks connecting
How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci
Firmware Loader User Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876
Chapter 1 Installing the Gateway
Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information
Remote Serial over IP Introduction on serial connections via IP/Ethernet
Remote Serial over IP Introduction on serial connections via IP/Ethernet TABLE OF CONTENT TABLE OF CONTENT... I TABLE OF IMAGES... I INTRODUCTION... 1 Classic Style of Communication... 1 Ethernet and
A6210 WiFi USB Adapter 802.11ac USB 3.0 Dual Band User Manual
802.11ac USB 3.0 Dual Band User Manual August 2014 202-11373-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the
PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999
232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been
Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
Router Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,
Designing VM2 Application Boards
Designing VM2 Application Boards This document lists some things to consider when designing a custom application board for the VM2 embedded controller. It is intended to complement the VM2 Datasheet. A
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
UDS10 UDS100 User Guide
UDS10 UDS100 User Guide Part Number 900-360 Revision A June 2004 Copyright & Trademark 2004, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any
DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.
DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS REV 04.11 LOCAL AREA NETWORK (LAN) CONNECTION Ethernet Connection: An Ethernet Cable, or wireless connection must
Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:
the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
FBs-CM25/CM55/CBE. Ethernet Module. User s Manual
FBs-CM25/CM55/CBE Ethernet Module User s Manual Ver. 2.1 Fatek Automation Corp. 7/1/2004 1. Preface...2 2. Specification...2 2.1 Serial Communication Connector(FBS-CM25E/CM55E only)...2 2.2 Ethernet Serial
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
WHQL Certification Approval...2 User Interface...3 128K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5
0 INDEX WHQL Certification Approval...2 User Interface...3 128K software FIFO 4 Universal PCI Interface...5 Ready for 64-bit System...5 1.0 Introduction 6 2.0 Features.. 6 3.0 Hardware Guide... 7 3.1 System
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
NBG2105. User s Guide. Quick Start Guide. Wireless Mini Travel Router. Default Login Details. Version 1.00 Edition 1, 11/2012
NBG2105 Wireless Mini Travel Router Version 1.00 Edition 1, 11/2012 Quick Start Guide User s Guide LAN IP Address Default Login Details 192.168.1.1 (Router Mode) 192.168.1.2 (Other Modes) Passwordwww.zyxel.com
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
Application Note. Terminal Server G6
MICROSENS GmbH & Co. KG Küferstr. 16 59067 Hamm/Germany Tel. +49 2381 9452-0 FAX +49 2381 9452-100 E-Mail [email protected] Web www.microsens.de Summary As of firmware version v10.6 MICROSENS Generation
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking
POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides
EMG Ethernet Modbus Gateway User Manual
EMG Ethernet Modbus Gateway User Manual Rev 2.2 07/2010 CONTENTS 1. Introduction 1.1. General Features 1.2 Installing the Drivers 2. Configuration 2.1 Main Device Parameters 2.1.1 RS485 Serial Communication
Installing an Omnicast System Omnicast version 3.5
Installing an Omnicast System Omnicast version 3.5 INST-9001 Version 1.0 INST-9001 Page 1 Omnicast Install Table of Contents 1 PREAMBLE...3 1.1 DOCUMENT REVISIONS...3 1.2 OMNICAST OVERVIEW...3 1.3 SUPPORTED
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 1.6 Page 1 Publication Revision No. Control Table Rev. No. Date Contents 1.6 8/22/07 Support connection of multiple WM5.0 devices 1.5 6/18/07 Support
Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.
2,4 GHz WIRELESS Wireless-N PCI Adapter User Guide Model No. WMP300N (EU) Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered trademark or trademark of
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL
WiFly Evaluation Kit 2012 Roving Networks. All rights reserved. Version 1.32r 10/9/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks evaluation kits,
ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER
User s Guide PMCM-ETHCC-0208 2/2008 ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER TABLE OF CONTENTS INTRODUCTION... 2 Supported Ethernet Protocols... 2 Hardware... 2 Meter Firmware...
UDS1100 User Guide Part Number 900-417 Revision B June 2006
UDS1100 User Guide Part Number 900-417 Revision B June 2006 Copyright & Trademark Contacts 2006, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in
English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list
LW320/LW321 Sweex Wireless 300N Router Do not expose the Sweex Wireless 300N Router to extreme temperatures. Do not place the device in direct sunlight or in the direct vicinity of heating elements. Do
Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature
Table of Content Error Messages List... 2 Troubleshooting the Storage System... 3 I can t access the Manager... 3 I forgot the password for logging in to the Manager... 3 The users can t access the shared
NPort DE-311 Hardware Installation Guide
NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
isco Connecting Routers Back to Back Through the AUX P
isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
Prestige 660R-6x Read Me First
Prestige 660R-6x Read Me First Prestige Rear Panel Connections DSL PORT CONNECTION Connect the DSL port on the Prestige to the wall jack using the included DSL cable (telephone wire). Connect the micro
VSCOM USB PRO Series Industrial I/O Adapters
VSCOM USB PRO Series Industrial I/O Adapters 1.Introduction The VSCOM USB PRO Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS-232/422/485 serial devices.
