Basic Operating Characteristics of CO2 Refrigeration Cycles With Expander-Compressor Unit
|
|
|
- Bernard Doyle
- 9 years ago
- Views:
Transcription
1 Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Basic Operating Characteristics of CO2 Refrigeration Cycles With Expander-Compressor Unit Hirokatsu Kohsokabe Hitachi Ltd. Sunao Funakoshi Hitachi Ltd. Kenji Tojo Hitachi Ltd. Susumu Nakayama Hitachi Ltd. Kyoji Kohno Hitachi Ltd. See next page for additional authors Follow this and additional works at: Kohsokabe, Hirokatsu; Funakoshi, Sunao; Tojo, Kenji; Nakayama, Susumu; Kohno, Kyoji; and Kurashige, Kazutaka, "Basic Operating Characteristics of CO2 Refrigeration Cycles With Expander-Compressor Unit" (2006). International Refrigeration and Air Conditioning Conference. Paper This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at Herrick/Events/orderlit.html
2 Authors Hirokatsu Kohsokabe, Sunao Funakoshi, Kenji Tojo, Susumu Nakayama, Kyoji Kohno, and Kazutaka Kurashige This article is available at Purdue e-pubs:
3 R159, Page 1 BASIC OPERATING CHARACTERISTICS OF CO 2 REFRIGERATION CYCLES WITH EXPANDER-COMPRESSOR UNIT Hirokatsu Kohsokabe 1, Sunao Funakoshi 2, Kenji Tojo 3, Susumu Nakayama 3, Kyoji Kohno 3, Kazutaka Kurashige 4 1 Hitachi, Ltd., Mechanical Engineering Research Laboratory, 832-2, Horiguchi, Hitachinaka-shi, Ibaraki , Japan (Fax: 81(29) , [email protected]) 2 Hitachi, Ltd., Advanced Research Laboratory, 2520 Hatoyama, Saitama , Japan 3 Hitachi Appliances, Inc., Air Conditioning Systems Division, 390 Muramatsu, Shimizu-ku Shizuoka-shi , Japan 4 Tokyo Electric Power Company, R&D Center, 4-1 Egasaki-cho, Tsurumi-ku, Yokohama , Japan ABSTRACT A transcritical CO 2 refrigeration cycle with an expander was studied to improve the coefficient of performance (COP) of the cycle of a simple expansion valve by recovering the throttling loss. We developed an expandercompressor unit. A scroll type expander and a rolling-piston type rotary sub-compressor were adopted and connected them with a shaft. With this unit, we made a CO 2 refrigeration cycle for a small capacity air-cooled chiller and investigated the basic operating characteristics of the cycle. In experiments, the expander-compressor unit was shown to be stable and to improve the COP of the CO 2 chiller cycle under both cooling and heating conditions. The test results indicated that the COP improvement of the cycle was more than 30%, while the total efficiency of the expander-compressor unit was 57%. Expander-compressor unit are a key technology for use in CO 2 refrigeration systems. 1. INTRODUCTION Recently, natural refrigerants have been receiving attention due to global environmental problems. Carbon dioxide (CO 2 ), a natural refrigerant, is a potential substitute for hydrofluorocarbons (HFCs) because of its incombustibility, non-toxicity and low global warming potential (GWP). The coefficient of performance (COP) of CO 2 refrigeration cycles, however, is typically low compared to the HFC refrigeration cycles. The main reason for this low COP is large throttling loss that results from a transcritical refrigeration cycle. Many researchers have been trying to improve the COP of transcritical CO 2 refrigeration cycles. The throttling loss can be reduced by replacing the expansion valve with a work output expansion device (expander or ejector). Various types of expanders have been studied to recover the throttling loss of the CO 2 refrigeration cycles. For example, Nickl et al. (2005) developed a third generation CO 2 reciprocating expander, which has three independent expansion stages. Hays and Brasz (2004) analyzed a transcritical turbine-compressor for CO 2 refrigeration and heat pump systems. Westphalen and Dieckmann (2004) analyzed a scroll expander for CO 2 refrigerant-cooling systems. Similar research is going on in many other companies and universities with different types of expander designs. However, the amount of research for operating characteristics of the CO 2 refrigeration cycle with expanders is relatively small. Fukuta et al. (2001) studied the theoretical performance of the CO 2 cycle with a vane compressor-expander combination. Taking account of the loss due to miss-matching of the operating condition, the theoretical COP of the cycle with the expander was found to be approximately 1.5 times larger than the cycle without the expander. Hiwata et al. (2003) investigated the theoretical performance of the cycle with the expander for both cooling and heating operations. A new refrigeration cycle (change over cycle) was proposed as a cycle with an expander for CO 2 airconditioning systems. This paper shows the experimental performance of a transcritical CO 2 refrigeration cycle with an expandercompressor unit and presents its operating characteristics for both cooling and heating conditions.
4 R159, Page 2 2. CO 2 REFRIGERATION CYCLE WITH EXPANDER-COMPRESSOR UNIT A CO 2 refrigeration cycle with an expander-compressor unit is shown in Figure 1. This cycle is for an air-cooled heat pump chiller. The specifications of the cycle components are shown in Table 1. The refrigeration cycle consists of a main compressor (MC), an oil separator, a four-way valve, an air-side heat exchanger, an expander-compressor unit, a water/refrigerant heat exchanger, check valves, and etc. The expander-compressor unit includes an expander (EX) and a sub-compressor (SC). In Figure 1, a solid arrow shows the flow of the refrigerant during cooling operation and a broken arrow shows the flow during heating operation. The four-way valve changes these two operating modes. In both cooling and heating operation, check valves fix the flow direction of the refrigerant to the expander so that the expander always recovers the energy. This recovered energy directly drives the sub-compressor. Here, the sub-compressor acts as a boosted compressor and reduces the power of the main compressor. Figure 2 shows an ideal P-h diagram of the CO 2 cycle with the expander-compressor unit. An expansion process and a compression process are assumed to be isentropic. The line from point A to B indicates the compression process of the sub-compressor, and the line from point B to C indicates the compression process of the main-compressor. The line from point D to E indicates the expansion process of the expander. The total efficiency of the expandercompressor unit η t is defined by η t =Δh sc /Δh ex (1) whereδh sc is the isentropic enthalpy difference of the sub-compressor, and Δh ex is the isentropic enthalpy difference of the expander. In Figure 2, the evaporating temperature T e is, the suction super-heat degree is 0, the heat rejection pressure P h is 9.0MPa and the expander inlet temperature T i is 36. The theoretical COP improvement of the cycle with the expander-compressor unit is shown in Figure 3. It can be seen that for the given conditions, the cycle with the expander-compressor unit has a 30% improvement in COP over the basic transcritical CO 2 cycle, while the total efficiency of the expander-compressor unit η t is 50%. 3. EXPANDER-COMPRESSOR UNIT Figure 4 shows a sectional view of the expander-compressor unit (ECU). We used a scroll type expander and a rolling-piston type rotary sub-compressor. Both elements were connected with a crankshaft, so both rotate at the same speed. The ECU design condition is a cooling rated condition. The ECU is lubricated by polyalkylene glycol (PAG) oil, which is stored in the bottom of the casing. The end of the crankshaft is under the oil. The oil pick up supplies the oil to the axial bore of the crankshaft and then feeds it to bearings and other sliding surfaces. The oil separator supplies oil to the casing oil sump (see Figure 1). 4. EXPERIMENT The test conditions are shown in Table 2. The experiments were carried out at different refrigerant charges, ambient temperatures, and water inlet temperatures for both cooling and heating conditions. The performance of the CO 2 cycle with the ECU was compared with the performance of the CO 2 cycle without the ECU (with expansion valve). In one testing cycle, the temperature and pressure at each component, the refrigerant mass flow rate, the compressor power input, and the rotating speed of the ECU were measured. The system capacity calculated to the amount of heat exchange from the water side. The cooing or heating capacity Q is given as Q = ρ w C w V w ΔT (2) where ρ w is the water density, C w is the heat capacity of water, V w is the volume flow rate of water, andδt is the average temperature difference between the inlet and outlet water of the water/refrigerant heat exchanger. The COP is the ratio of the cooling or heating capacity to the compressor power input, which is defined by where W i is the compressor power input. COP = Q/W i (3)
5 R159, Page 3 In experiments, the ECU was stable under both cooling and heating conditions. 5. TEST RESULTS 5.1 Effects of refrigerant charge Figure 5 shows the effects of the refrigerant charge on system performance. Figure 5(a) is a cooling rated condition and Figure 5(b) is a heating rated condition. The relative COP, the system capacity, and the compressor power input were charted. In Figure 5(a), overall, when the refrigerant charge increases, the cooling capacity increases, but its rate of increase is gradually saturates. On the other hand, the compressor power input slightly increases, so the COP has a maximum point at a specific refrigerant charge. The optimum refrigerant charge is 6.4 kg with the ECU and 6.7 kg without the ECU. In Figure 5(b), the results of the heating rated condition are similar to but smaller than the refrigerant charge of the cooling rated condition. The optimum refrigerant charge is 3.35 kg with the ECU and 3.6 kg without the ECU. In Figure 5, the CO 2 refrigeration cycle with the ECU improved the COP by more than 30%. 5.2 Effects of inlet water temperature Figure 6-7 shows the effects of inlet water temperature. The refrigerant charge remained at the optimum value. Figure 6 shows the relative COP at the cooling condition. Figure 7 shows the relative COP at the heating condition. The COP with the ECU is above the COP without the ECU. These results indicate that though the ECU was designed for the cooling rated condition, it improves the COP of the cycle under the different operating conditions. Figure 8 shows a P-h diagram of the CO 2 cycle with the ECU at cooling rated condition. In this figure, the line from point A to B indicates the compression process of the ECU, and the line from point D to E indicates the expansion process of the ECU. A two-dot chain line means a constant entropy S. Based on this figure, the results from Equation (1), the total efficiency η t is 57%. 6. CONCLUSIONS We have developed an expander-compressor unit and investigated the basic operating characteristics of the CO 2 refrigeration cycle. As a result, the following conclusions were obtained: The expander-compressor unit improves the COP of the CO 2 chiller cycle under both cooling and heating conditions. The COP improvement of the cycle with the expander-compressor unit was more than 30%, while the total efficiency of the expander-compressor unit was 57%. Expander-compressor unit are a key technology for use in CO 2 refrigeration systems. REFERENCES Nickl, J., et al., 2005, Integration of a three-stage expander into a CO 2 refrigeration systems, Int. J. Refrig., vol. 28, no. 8: p Hays, L., Brasz, J.J., 2004, A transcritical CO 2 turbine-compressor, International Compressor Engineering Conference at Purdue, C137. Westphalen, D., Dieckmann, J., 2004, Scroll expander for carbon dioxide air conditioning cycles, International Refrigeration and Air Conditioning Conference at Purdue, R023. Fukuta, M., et al., 2003, Performance prediction of vane type expander for CO 2 -cycle, Proceedings of the 21 st IIR International congress of the refrigeration Washington, ICR251. Kosuda, O., et al., 2005, Performance of scroll expander for CO 2 refrigeration cycle, Proceedings of the 2005 JSARE Annual Conference, C315 (in Japanese). Okamoto, M., et al., 2005, Development of two-phase flow expander for CO 2 air-conditioners, Proceedings of the 2005 JSARE Annual Conference, C316 (in Japanese). Fukuta, M., et al., 2001, Cycle performance of CO 2 cycle with vane compressor-expander combination, IMechE Conf. Trans. of Int. Conf. on Compressors and their Systems, p Hiwata, A., et al., 2003, A study of cycle performance improvement with expander-compressor in air-conditioning systems, IMechE Conf. Trans. of Int. Conf. on Compressors and their Systems, p
6 R159, Page 4 Air-side 空 Heat 気 側 Exchanger 熱 交 換 器 4-way 四 valve 方 弁 Oil オイルセパレータ Separator Check 逆 valve 止 弁 Fan ファン 調 整 弁 Motor モータ Main 主 圧 縮 Compressor 機 EX SC M MC Expander-Compressor 膨 張 / 圧 縮 機 Unit Water/Refrigerant 水 側 熱 交 換 器 Heat Exchanger Load 負 荷 P Pump ポンプ Cooling 冷 却 運 転 Heating 加 熱 運 転 Figure 1: CO 2 air-cooled chiller cycle with expander-compressor unit Table 1: Specifications of CO 2 cycle components Main Compressor Type Motor Scroll AC, 200V, 3.75kW Expander-Compressor Unit Expander Subcompressor Type Type Scroll Rolling-Piston Rotary Air-side Heat Exchanger Type Cross-Fin Tube Water/Refrigerant Heat Exchanger Type Plate and Tube
7 R159, Page 5 12 S : Entropy Pressure P [MPa] S const. E h ex D 36 T e = A C S const. B h sc Figure 2: P-h diagram of En CO thalpy 2 cycle h with [kj/kg] expander-compressor unit Figure 2: P-h diagram of CO 2 cycle with expander-compressor unit COP 向 上 率 (%) COP Improvement [%] R744 T e = P h = 9.0 MPa T i = Total Efficiency 膨 張 / 圧 of 縮 Expander-Compressor 機 の 機 関 効 率 ηt(%) Unit η t [%] Figure 3: COP improvement of CO 2 cycle with expander-compressor unit
8 R159, Page 6 Casing Scroll Expander Fixed Scroll Orbiting Scroll Balance Weight Crankshaft Rotary Sub-compressor Cylinder Lubricating Oil Roller Oil Pick Up Figure 4: Cross-sectional view of expander-compressor unit Table 2: Test conditions Expansion Device Operating Mode Charge of CO 2 [kg] Ambient Temperature: T a [ ] Water Inlet Temperature: T wi [ ] Expansion Valve Cooling Heating 4.2~ ~ ~ ~45 Expander- Compressor Unit Cooling Heating 4.5~ ~ ~ ~45
9 R159, Page 7 Relative COP[-] Relative Cooling Capacity[-] Relative Comp. Input[-] T a = 35 T wi = 12 V w = 30 l/min (a) Cooling Rated Condition Relative COP[-] Relative Heating Capacity[-] Relative Comp. Input[-] T a = 7 T wi = 40 V w = 38 l/min (b) Heating Rated Condition Figure 5: Effect of refrigerant charge on performance
10 R159, Page Relative COP[-] T a = 35 V w = 30 l/min Relative COP [-] T a = 7 V w = 38 l/min Water Inlet Temperature Twi [ ] Water Inlet Temperature Twi [ ] Figure 6: Effect of water inlet temperature on COP (cooling mode) Figure 7: Effect of water inlet temperature on COP (heating mode) 10 D C Pressure P [MPa] S const. Δh ex E A B Δh sc S const. S: Entropy Enthalpy h [kj/kg] Figure 8: P-h diagram of cooling rated condition
Research on the Air Conditioning Water Heater System
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 28 Research on the Air Conditioning Water Heater System Fei Liu Gree Electric
High Pressure Ammonia Systems New Opportunities
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 High Pressure Ammonia Systems New Opportunities Andy Pearson Star Refrigeration
Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 00 Measurement And Application of Performance Characteristics Of A Free Piston
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
The Development of Heat Pump Water Heaters Using CO 2 Refrigerant
The Development of Heat Pump Heaters Using CO 2 Refrigerant Shigeharu TAIRA* * DAIKIN Industries, Ltd., 1000-2 Aza-Ohtani, Okamoto-cho, Kusatsu, Shiga 525-8526 Abstract heating consumes about one-third
PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.
International Journal of Emerging Trends in Engineering and Development Issue 3, Vol. (January 23) EFFECT OF SUB COOLING AND SUPERHEATING ON VAPOUR COMPRESSION REFRIGERATION SYSTEMS USING 22 ALTERNATIVE
Experimental Analysis of a Variable Capacity Heat Pump System Focusing on the Compressor and Inverter Loss Behavior
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 21 Experimental Analysis of a Variable Capacity Heat Pump System Focusing on
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A Jignesh K. Vaghela Assistant Professor, Mechanical Engineering Department, SVMIT, Bharuch-392001, (India) ABSTRACT
Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1
Lesson Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications Version ME, IIT Kharagpur The objectives of this lecture are to discuss. Performance aspects of SSS cycle and
Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
Chapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
Experimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering Experimental Analysis of an Automotive Air Conditioning System With Two-Phase
Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:
PART 1: CO 2 Commercial refrigeration has been in the environmental spotlight for more than a decade, especially as leakage studies have revealed the true effects of hydrofluorocarbon (HFC) emissions.
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems William M. Corcoran, George Rusch, Mark W. Spatz, and Tim Vink AlliedSignal, Inc. ABSTRACT
UNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
Experimental Evaluation Of The Frost Formation
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Evaluation Of The Frost Formation Yusuke Tashiro Mitsubishi
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss.
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant Pierre Ginies, Next Heat Pump Generation 2015 [email protected] Danfoss Commercial Compressors Leading compressor R&D and manufacturing
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES INTRODUCTION This tutorial is designed for students wishing to extend their knowledge of thermodynamics to a more
PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A
Int. J. Mech. Eng. & Rob. Res. 213 Jyoti Soni and R C Gupta, 213 Research Paper ISSN 2278 149 www.ijmerr.com Vol. 2, No. 1, January 213 213 IJMERR. All Rights Reserved PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION
AIR REVERSING R744 AIR CONDITIONING SYSTEM
AIR REVERSING R744 AIR CONDITIONING SYSTEM A.HAFNER 1 ; D.J. GARSKI 2 ; J. MANZIONE 3 1 SINTEF Energy Research, 7465 Trondheim, Norway, [email protected] 2 MODINE, Racine, USA, [email protected]
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 22 Refrigeration System Components: Compressor (Continued)
HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS
1 HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS Jørn Stene SINTEF Energy Research, 7465 Trondheim, Norway [email protected] In hotels, hospitals,
Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets
2 Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets - Extending Use of New Heat Pump System in Cold Regions
How To Calculate The Performance Of A Refrigerator And Heat Pump
THERMODYNAMICS TUTORIAL 5 HEAT PUMPS AND REFRIGERATION On completion of this tutorial you should be able to do the following. Discuss the merits of different refrigerants. Use thermodynamic tables for
Mohan Chandrasekharan #1
International Journal of Students Research in Technology & Management Exergy Analysis of Vapor Compression Refrigeration System Using R12 and R134a as Refrigerants Mohan Chandrasekharan #1 # Department
New Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
Analytical Study on the Performance Characteristics of a Liquid Injection Refrigeration Cycle.
urdue University urdue e-ubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Analytical Study on the erformance Characteristics of a Liquid Injection Refrigeration
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
Low GWP Replacements for R404A in Commercial Refrigeration Applications
Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, [email protected] Abstract
Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning
Commercial CO 2 Refrigeration Systems
Commercial CO 2 Refrigeration Systems Guide for Subcritical and Transcritical CO 2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section
CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank
CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS Blank SONNTAG/BORGNAKKE STUDY PROBLEM 7-1 7.1 A car engine and its fuel consumption A car engine produces 136 hp on the output shaft with a thermal efficiency
Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling
for Simultaneous Heating and Cooling F. Sustainable Energy Centre, University of South Australia Mawson Lakes Boulevard, Mawson Lakes 5095 AUSTRALIA E-mail: [email protected] Abstract The high efficiency
Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.
Thermo 1 (MEP 261) Thermodynamics An Engineering Approach Yunus A. Cengel & Michael A. Boles 7 th Edition, McGraw-Hill Companies, ISBN-978-0-07-352932-5, 2008 Sheet 5:Chapter 5 5 1C Name four physical
Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 11, Issue 3 Ver. VII (May- Jun. 2014), PP 92-97 Analytical Study of Vapour Compression Refrigeration
AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY
AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY Wiebke Brix (a), Stefan W. Christensen (b), Michael M. Markussen (c), Lars Reinholdt (d) and Brian Elmegaard (a) (a) DTU Technical University
A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures
R2-1 A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures W. Vance Payne and Piotr A. Domanski National Institute of Standards and Technology Building Environment
A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine
A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine G Vicatos J Gryzagoridis S Wang Department of Mechanical Engineering,
POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES
POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES M. Bantle 1, I. Tolstorebrov, T. M. Eikevik 2 1 Department of Energy Efficiency, SINTEF Energy Research, Trondheim, Norway,
Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange
Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange ING. TOMMASO FERRARESE Thermodynamics Laboratory Engineer
TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #31 System Drop-in Test of Refrigerant R-32 in Split Air-conditioning
Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Study on Performance Evaluation of a Split Air Conditioning System Under
9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS
9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS 9.1 Introduction Air conditioning and refrigeration consume significant amount of energy in buildings and in process industries. The energy consumed in
Thermodynamics - Example Problems Problems and Solutions
Thermodynamics - Example Problems Problems and Solutions 1 Examining a Power Plant Consider a power plant. At point 1 the working gas has a temperature of T = 25 C. The pressure is 1bar and the mass flow
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
Test Report issued under the responsibility of:
Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat
FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM
FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM L. H. M. Beatrice a, and F. A. S. Fiorelli a a Universidade de São Paulo Escola Politécnica Departamento de Engenharia Mecânica Av. Prof.
Isentropic and Volumetric Efficiencies for Compressors with Economizer Port
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Isentropic and Volumetric Efficiencies for Compressors with Economizer Port Klaus Jurgen
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
How To Design A Refrigeration System
AIRAH Refrigeration (in HVAC) Back to Basics For the First Time Terms of Reference What this session is NOT about Detailed Refrigeration Design Detailed analysis of various Refrigants properties Comparison
UNDERSTANDING REFRIGERANT TABLES
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING REFRIGERANT TABLES INTRODUCTION A Mollier diagram is a graphical representation of the properties of a refrigerant,
Heat and Mass Transfer Calculation of the Intercooler With Spraying Water for Air Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1996 Heat and Mass Transfer Calculation of the Intercooler With Spraying Water for Air Compressor
Applications in Mobile Air-Conditioning and Applications in Heat Pumps
Carbon Dioxide as Refrigerant Applications in Mobile Air-Conditioning and Applications in Heat Pumps Petter Nekså Senior Research Scientist, Norway 1 SINTEF location, Trondheim, Norway SINTEF does contract
Silicagel-water adsorption cooling prototype system for mobile air conditioning
Silicagel-water adsorption cooling prototype system for mobile air conditioning R. de Boer S.F. Smeding S. Mola Paper to be presented at the Heat Powered Cycles Conference 09 Berlin, 7 to 9 September 2009
COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES
COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 TIME SCHEDULE MODULE TOPICS PERIODS 1 Introduction 22 Principles
Oil Injection Rotary Screw Compressors Contributing to Environmental Protection and Energy Conservation
Hitachi Review Vol. 6 (211), No. 5 245 Oil Injection Rotary Screw Compressors Contributing to Environmental Protection and Energy Conservation Hideharu Tanaka Yuji Kamiya Masahiko Takano Tsutomu Nozaki,
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications
Commercial CO2 Refrigeration Systems Guide for Subcritical and Transcritical CO2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section 1.
Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance
Refrigerant Choices for Commercial Refrigeration Finding the Right Balance 2 CONTENTS 1. Executive Summary 1.1. Introduction 4 1.2. Glossary of terms 5 5. Cases configuration 5.1. Introduction 17 5.2.
Thermal Coupling Of Cooling and Heating Systems
This article was published in ASHRAE Journal, February 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not
MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING
MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,
Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram
Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram Copy Right By: Thomas T.S. Wan 温 到 祥 著 Sept. 3, 2008 All rights reserved Industrial refrigeration system design starts from
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential
International Journal of Scientific and Research Publications, Volume 2, Issue 9, September 2012 1 A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of
A comparison of heterogenous and homogenous models of two-phase transonic compressible
Home Search Collections Journals About Contact us My IOPscience A comparison of heterogenous and homogenous models of two-phase transonic compressible CO 2 flow through a heat pump ejector This content
Development and testing of a multi-type air conditioner without using AC inverters
Energy Conversion and Management 46 (2005) 373 383 www.elsevier.com/locate/enconman Development and testing of a multi-type air conditioner without using AC inverters Shih-Cheng Hu *, Rong-Hwa Yang Department
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 21 Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Development of the Inverter Air Conditioner for Southeast Asia in FY2014
152 Hitachi Review Vol. 64 (2015), No. 2 Featured Articles Development of the Inverter Air Conditioner for Southeast Asia in Takao Nagata Juhri Yasin Yasuhiro Kishi Ayumi Wada OVERVIEW: Hitachi has released
REFRIGERATION (& HEAT PUMPS)
REFRIGERATION (& HEAT PUMPS) Refrigeration is the 'artificial' extraction of heat from a substance in order to lower its temperature to below that of its surroundings Primarily, heat is extracted from
01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
Percent per Degree Rule of Thumb for Refrigeration Cycle Improvement
7 Percent per Degree Rule of Thumb for Refrigeration Cycle Improvement Steve Doty, PE, CEM [email protected] ABSTRACT A value of 1-1.5% power reduction per degree Fahrenheit (F) has been used successfully
Efficiency of Hydrogen Liquefaction Plants
Efficiency of Hydrogen Liquefaction Plants Takashi FUKANO**, Urs FITZI*, Karl LÖHLEIN*, Isabelle VINAGE* * Linde Kryotechnik AG, CH-8422 Pfungen, Switzerland ** Nippon Sanso Corporation, JP-210-0861 Kawasaki-City,
Development of CO 2 A/C System
Development of CO 2 A/C System CK s s Aiming of CO 2 Air Conditioning System Aiming CK develops two kinds of CO 2 air conditioning systems. These are the one for the vehicles of a source of the present
RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm)
RS-52 (R428A) COMPOSITION % HFC 125 77.5 HFC 143a 20.0 R600a 1.9 R290 0.6 HCFC replacement Temperature glide R22, 502 & interim blends Approximately 0.8 o C Drop-in or long term Both Lubricant MO/AB/POE
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
Increasing the evaporation temperature with the help of an internal heat exchanger
Increasing the evaporation temperature with the help of an internal heat exchanger A. TAMBOVTSEV (a), H. QUACK (b) (a,b) Technische Universität Dresden, D-01062, Dresden, Germany (a) Fax: (+49351) 463-37247,
2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units
2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units ANSI/AHRI Standard 540 (formerly ARI Standard 540) IMPORTANT SAFETY RECOMMENDATIONS ARI does not
Energy Efficiency Best Practice Guide Industrial Refrigeration
3 Energy Efficiency Best Practice Guide Contents 1 Introduction 4 2 The business benefits of efficient refrigeration 5 3 What is your opportunity? 6 4 Solution 1 Improve the efficiency of your existing
TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
Combined Air-conditioning and Tap Water Heating Plant, Using CO2 as Refrigerant for Indonesian Climate Condition. By Willy Adriansyah
Combined Air-conditioning and Tap Water Heating Plant, Using CO2 as Refrigerant for Indonesian Climate Condition By Willy Adriansyah Thesis submitted in partial fulfillment of the requirements for the
Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling
Computers and Chemical Engineering 31 (2007) 712 721 Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling Jørgen Bauck Jensen, Sigurd Skogestad Department
APPLIED THERMODYNAMICS. TUTORIAL No.3 GAS TURBINE POWER CYCLES. Revise gas expansions in turbines. Study the Joule cycle with friction.
APPLIED HERMODYNAMICS UORIAL No. GAS URBINE POWER CYCLES In this tutorial you will do the following. Revise gas expansions in turbines. Revise the Joule cycle. Study the Joule cycle with friction. Extend
Refrigerant Charge and Ambient Temperature Effects on the Refrigeration Cycle of a Small Capacity Food Freezer
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 24 Refrigerant Charge and Ambient Temperature Effects on the Refrigeration Cycle
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
Guidelines of how to instrument, measure and evaluate refrigeration systems in supermarkets PAU GIMÉNEZ GAVARRELL
Guidelines of how to instrument, measure and evaluate refrigeration systems in supermarkets PAU GIMÉNEZ GAVARRELL Master of Science Thesis Stockholm, Sweden 2011 What is not measured does not exist; What
Characteristics of Evaporators
Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of
Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics
International Journal of Scientific & Engineering Research Volume 2, Issue 8, August-2011 1 Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics
Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65
Available online at www.sciencedirect.com Available online at www.sciencedirect.com Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65 Energy Procedia www.elsevier.com/locate/procedia ICAEE
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
Evaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications
Evaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications Thomas J. Leck DuPont Fluorochemicals Wilmington, Delaware 3rd IIR Conference on Thermophysical Properties and
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
Reflux Gas Densification Technology An Innovative Dry Compression Process
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2002 Reflux Gas Densification Technology An Innovative Dry Compression Process J. W. Payne
Optimization of combined heating and cooling in Supermarkets
Optimization of combined heating and cooling in Supermarkets Funder-Kristensen T. 1 ; Fösel G. 2 and Bjerg P. 3 1 Ph.d. Head of Public & Industry Affairs, Danfoss, Nordborg, 6430, Denmark. 2 Dipl.-Ing.
