BELL WEATHERPROOF BOXES, COVERS AND LIGHTING
|
|
|
- Albert Welch
- 9 years ago
- Views:
Transcription
1 BELL WEATHERPROOF BOXES, COVERS AND LIGHTING
2 STANDARDS, 2014 NATIONAL ELECTRICAL CODE BELL UPC Vendor Number Where applicable, BELL products are engineered in accordance with the standards established by Underwriters Laboratories and the Canadian Standards Association. Dimensional data listed in this catalog is intended for general reference with broad tolerance limits NEC When specifying BELL Weatherproof boxes and covers, consult the requirements of the National Electrical Code, Article (B) and (B). Article (B) details the NEC requirements for the maximum number of conductors allowed for a BELL Weatherproof installation. Article (B) provides details on the NEC requirements for receptacles being used in wet locations. For your convenience, we have reprinted the pertinent NEC articles. In all cases, consult your local electrical code and inspector interpretation. Wiring Capacity: BELL Weatherproof Boxes and Extensions Maximum Number of Conductors or Minimum Size Box (Article (B) The purpose of Section (B) is to determine the maximum conductor count or the minimum box size required for the job. It also can be used to figure how many other conductors may be added without exceeding the Code-prescribed limit. Most applications have determined the number of conductors. The rules of Section (B) are used to determine the Code recognized limit, or smallest box that may be installed. Selection of any HUBBELL TAYMAC Weatherproof box or extension for use in any electrical circuit work must take into consideration the maximum number of wires permitted in the box. Safe electrical practice demands that wires not be jammed into boxes because of the possibility of nicks, abrasions, or other damage to the insulating material, creating the potential for ground faults or short circuits Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies. Boxes and conduit bodies shall be of an approved size to provide free space for all enclosed conductors. In no case shall the volume of the box, as calculated in (A), be less than the fill calculation as calculated in (B). The minimum volume for conduit bodies shall be as calculated in (C). The provisions of this section shall not apply to terminal housings supplied with motors or generators. Boxes and conduit bodies enclosing conductors 4 Standards AWG or larger shall also comply with the provisions of (A) Box Volume Calculations. The volume of a wiring enclosure (box) shall be the total volume of the assembled sections and, where used, the space provided by plaster rings, domed covers, extension rings, and so forth, that are marked with their volume or are made from boxes the dimensions of which are listed in Table (A). (1) Standard Boxes. The volumes of standard boxes that are not marked with their volume shall be as given in T able (A). (2) Other Boxes. Boxes 1650 cm3 (100 in.3) or less, other than those described in Table (A), and nonmetallic boxes shall be durably and legibly marked by the manufacturer with their volume. Boxes described in Table (A) that have a volume larger than is designated in the table shall be permitted to have their volume marked as required by this section. (B) Box Fill Calculations. The volumes in paragraphs (B)(1) through (B)(5), as applicable, shall be added together. No allowance shall be required for small fittings such as locknuts and bushings. (1) Conductor Fill. Each conductor that originates outside the box and terminates or is spliced within the box shall be counted once, and each conductor that passes through the box without splice or termination shall be counted once. Each loop or coil of unbroken conductor not less than twice the minimum length required for free conductors in shall be counted twice. The conductor fill shall be calculated using Table (B). A conductor, no part of which leaves the box, shall not be counted. Exception: An equipment grounding conductor or conductors or not over four fixture wires smaller than 14 AWG, or both, shall be permitted to be omitted from the calculations where they enter a box from a domed luminaire or similar canopy and terminate within that box. (2) Clamp Fill. Where one or more internal cable clamps, whether factory or field supplied, are present in the box, a single volume allowance in accordance with Table (B) shall be made based on the largest conductor present in the box. No allowance shall be required for a cable connector with its clamping mechanism outside the box. (3) Support Fittings Fill. Where one or more luminaire studs or hickeys are present in the box, a single volume allowance in accordance with Table (B) shall be made for each type of fitting based on the largest conductor present in the box. (4) Device or Equipment Fill. For each yoke or strap containing one or more devices or equipment, a double volume allowance in accordance with Table (B) shall be made for each yoke or strap based on the largest conductor connected to a device(s) or equipment supported by that yoke or strap. A device or utilization equipment wider than a single 50 mm (2 in.) device box as described in T able (A) shall have double volume allowances provided for each gang required for mounting. (5) Equipment Grounding Conductor Fill. Where one or more equipment grounding conductors or equipment bonding jumpers enter a box, a single volume allowance in accordance with Table (B) shall be made based on the largest equipment grounding conductor or equipment bonding jumper present in the box. Where an additional set of equipment grounding conductors, as permitted by (D), is present in the box, an additional volume allowance shall be made based on the largest equipment grounding conductor in the additional set. (C) Conduit Bodies. (1) General. Conduit bodies enclosing 6 AWG conductors or smaller, other than short-radius conduit bodies as described in (C)(3), shall have a cross-sectional area not less than twice the cross-sectional area of the largest conduit or tubing to which they can be attached. The maximum number of conductors permitted shall be the maximum number permitted by Table 1 of Chapter 9 for the conduit or tubing to which it is attached. (2) With Splices, Taps, or Devices. Only those conduit bodies that are durably and legibly marked by the manufacturer with their volume shall be permitted to contain splices, taps, or devices. The maximum number of conductors shall be calculated in accordance with (B). Conduit bodies shall be supported in a rigid and secure manner. (3) Short Radius Conduit Bodies. Conduit bodies such as capped elbows and service-entrance elbows that enclose conductors 6 AWG or smaller, and are only intended to enable the installation of the raceway and the contained conductors, shall not contain splices, taps, or devices and shall be of an approved size to provide free space for all conductors enclosed in the conduit body Receptacles in Damp or Wet Locations. (A) Damp Locations. A receptacle installed outdoors in a location protected from the weather or in other damp locations shall have an enclosure for the receptacle that is weatherproof when the receptacle is covered (attachment plug cap not inserted and receptacle covers closed). An installation suitable for wet locations shall also D2 BELL WEATHERPROOF
3 STANDARDS, 2014 NATIONAL ELECTRICAL CODE be considered suitable for damp locations. A receptacle shall be considered to be in a location protected from the weather where located under roofed open porches, canopies, marquees, and the like, and will not be subjected to a beating rain or water runoff. All 15- and 20-ampere, 125- and 250- volt nonlocking receptacles shall be a listed weatherresistant type. Informational Note: The types of receptacles covered by this requirement are identified as 5-15, 5-20, 6-15, and 6-20 in ANSI/NEMA WD , National Electrical Manufacturers Association Standard for Dimensions of Attachment Plugs and Receptacles. (B) Wet Locations. (1) Receptacles of 15 and 20 Amperes in a Wet Location. 15- and 20-ampere, 125- and 250-volt receptacles installed in a wet location shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted. An outlet box hood installed for this purpose shall be listed and shall be identified as extra-duty. All 15- and 20- ampere, 125- and 250-volt nonlocking-type receptacles shall be listed weather-resistant type. Informational Note No. 1: Requirements for extra-duty outlet box hoods are found in ANSI/UL 514D-2000, Cover Plates for Flush-Mounted Wiring Devices. Informational Note No. 2: The types of receptacles covered by this requirement are identified as 5-15, 5-20, 6-15, and 6-20 in ANSI/NEMA WD , National Electrical Manufacturers Association Standard for Dimensions of Attachment Plugs and Receptacles. Exception: 15- and 20-ampere, 125- through 250- volt receptacles installed in a wet location and subject to routine high-pressure spray washing shall be permitted to have an enclosure that is weatherproof when the attachment plug is removed. (2) Other Receptacles. All other receptacles installed in a wet location shall comply with (B)(2) (a) or (B)(2)(b). (a) A receptacle installed in a wet location, where the product intended to be plugged into it is not attended while in use, shall have an enclosure that is weatherproof with the attachment plug cap inserted or removed. (b) A receptacle installed in a wet location where the product intended to be plugged into it will be attended while in use (e.g., portable tools) shall have an enclosure that is weatherproof when the attachment plug is removed. (C) Bathtub and Shower Space. Receptacles shall not be installed within or directly over a bathtub or shower stall. (D) Protection for Floor Receptacles. Standpipes of floor receptacles shall allow floor-cleaning equipment to be operated without damage to receptacles. (E) Flush Mounting with Faceplate. The enclosure for a receptacle installed in an outlet box flush-mounted in a finished surface shall be made weatherproof by means of a weatherproof faceplate assembly that provides a watertight connection between the plate and the finished surface. GENERAL FEATURES AND BENEFITS BELL Weatherproof products all offer these features and benefits: Rugged seamless die cast construction that will not allow entry of moisture Reinforced connector outlets to provide a secure mechanical installation State-of-the-art powder coat paint for maximum weatherability and scratch resistance Bilingual instructions provided with every product Installation hardware and ground screws included where applicable Shrink-wrap packaging that keeps all components together UPC-A barcoding to help lower transaction costs Refer to the pages that follow for more specific information about BELL products. National Electric Code and NEC is a registered Trademark of the National Fire Protection Association. Calculate The Minimum Size Box Section (B) describes in detail the method of counting wires, as well as clamps, fittings, or devices (i.e., switches, receptacles, combination devices) by establishing an equivalent conductor-value for each. These values are added together to get a total number of conductors. The minimum size box is the smallest one in cubic inch size that can accommodate that number of conductors. Points to Remember: 1. No matter how many ground wires come into a box, they only count as one conductor within the box. 2. Any wire running unbroken through the box counts as one wire. 3. Each wire coming into a splice device (crimp or twist-on type) is counted as one wire. Table (B) Volume Allowance Required per Conductor Size of Free Space Within Box Conductor for Each Conductor (AWG) cm 3 in Each wire coming into the box and connecting to a device counts as one wire of that size. 5. Where devices are mounted in the box, the total conductor count must be increased by two for each mounting strap. Example Bell Weatherproof Supply power to a single switch with #14 conductors. Metal conduit will be used as the wire way. You must provide space for four conductors and one switch, totally a conductor count of 6. Read across the line in Table (B) for a #14 conductor. Multiply 6 times the free space within a box. For each conductor for a #14 conductor This example requires a minimum box of 12.0 cubic inches. D3
4 DIE CAST ALUMINUM SINGLE-GANG BOXES Applications For use in branch circuit wiring in wet, damp or dry locations. May be used as a weatherproof junction box, or as a housing for receptacles, switches and GFCI s. Reinforced connector outlets State-of-the-art powder coat finish Eight box mounting options with detachable lugs provided Two closure plugs included Ground screw installed Multi-lingual instructions in each package Internal threads on hubs comply with NEMA requirements. Hubs accept all threaded fittings and threaded conduit TO TO TO , , File C22.2 No. 18 NEMA 3R Rated , TO SEE End of SECTION (PG D34) FOR DETAILED DRAWINGS» CATALOG # CUBIC In. Description (cm 3 ) COLOR OUTLETS Pkg. Type STD. PKG. BARCODE 2" Deep, with Lugs Three Threaded Outlets 4-1/2" X 2-3/4" (299.9) Gray (3) 1/2" Shrink 20 IIIIIIII (299.9) White (3) 1/2" Shrink 20 IIIIIIII (299.9) Bronze (3) 1/2" Shrink 20 IIIIIIII (299.9) Gray (3) 1/2" Carded 6 IIIIIIII (299.9) White (3) 1/2" Carded 6 IIIIIIII (299.9) Bronze (3) 1/2" Carded 6 IIIIIIII (299.9) Gray (3) 1/2" Bulk (299.9) Gray (3) 3/4" Shrink 20 IIIIIIII (299.9) White (3) 3/4" Shrink 20 IIIIIIII (299.9) Gray (3) 3/4" Carded 6 IIIIIIII 2" Deep, with Lugs Four Threaded Outlets 4-1/2" X 2-3/4" (299.9) Gray (4) 1/2" Shrink 20 IIIIIIII (299.9) White (4) 1/2" Shrink 20 IIIIIIII (299.9) Bronze (4) 1/2" Shrink 20 IIIIIIII (299.9) Gray (4) 1/2" Carded 6 IIIIIIII (299.9) White (4) 1/2" Carded 6 IIIIIIII (299.9) Gray (4) 3/4" Shrink 20 IIIIIIII 2" Deep, with Lugs Five Threaded Outlets 4-1/2" X 2-3/4" (299.9) Gray (5) 1/2" Shrink 20 IIIIIIII (299.9) Gray (5) 3/4" Shrink 20 IIIIIIII (299.9) Gray (5) 1/2" Shrink 20 IIIIIIII (299.9) Gray (5) 3/4" Shrink 20 IIIIIIII 2-5/8" Deep, with Lugs Three Threaded Outlets 4-1/2" X 2-3/4" (368.7) Gray (3) 1/2" Shrink 15 IIIIIIII (368.7) Gray (3) 3/4" Shrink 15 IIIIIIII (368.7) Gray (3) 1" Shrink 15 IIIIIIII D4 BELL WEATHERPROOF
5 DIE CAST ALUMINUM SINGLE-GANG EXTENSIONS AND ADAPTERS , to (No ground screw provided) (Includes one closure plug) (Includes three closure plugs) CATALOG # CUBIC In. Description (cm 3 ) COLOR OUTLETS Pkg. Type STD. PKG. BARCODE Single-Gang Extension 4-1/2" X 2-3/4" X 1" Deep (155.7) Gray Shrink 25 IIIIIIII Single-Gang Extension Adapters 5-1/4" X 3-1/2" X 1-1/2" Deep Two threaded outlets (155.7) Gray (2) 1/2" Shrink 20 IIIIIIII (180.3) Gray (2) 3/4" Shrink 20 IIIIIIII Single-Gang Extension Adapters 5-1/4" X 3-1/2" X 1-1/2" Deep Six Threaded outlets (155.7) Gray (6) 1/2" Shrink 20 IIIIIIII (155.7) Gray (6) 1/2" Carded 6 IIIIIIII (180.3) Gray (6) 3/4" Shrink 20 IIIIIIII Applications Used to provide additional capacity needed for NEC box fill requirements. Adapters allow installer to add take-offs to new boxes/devices. Installation hardware, gasket, and ground screw provided Closure plugs provided for two and six outlet styles Internal threads and hubs comply with NEMA requirements. Hubs accept all threaded fittings and threaded conduit. File E C22.2 No. 18 NEMA 3R Rated , (Includes one closure plug) , (Includes three closure plugs) CATALOG # CUBIC In. Description (cm 3 ) COLOR OUTLETS Pkg. Type STD. PKG. BARCODE Swing-Arm Extension Adapters 5-1/4" X 3-1/2" X 1-1/2" Deep Two Threaded Outlets (226.1) Gray (2) 1/2" Shrink 10 IIIIIIII (226.1) Gray (2) 3/4" Shrink 10 IIIIIIII Swing-Arm Extension Adapters 5-1/4" X 3-1/2" X 1-1/2" Deep Six Threaded Outlets (209.8) Gray (6) 1/2" Shrink 10 IIIIIIII (209.8) Gray (6) 3/4" Shrink 10 IIIIIIII Applications Used to provide additional capacity needed for NEC box fill requirements. Allows installer to add take-offs to new boxes/devices. Unique swing-arm design speeds installation by allowing the installer better visibility when lining up and threading fasteners. Rugged die cast construction Reinforced connector outlets State-of-the-art powder coat finish Installation hardware, ground screw and gasket provided Multi-lingual instructions in each package Internal threads and hubs comply with NEMA requirements. Hubs accept all threaded fittings and threaded conduit. File E C22.2 No. 18 NEMA 3R Rated SEE End of SECTION (PG D34) FOR DETAILED DRAWINGS» D5
6 DIE CAST ALUMINUM two-gang BOXES Applications For use in branch circuit wiring in wet, damp, or dry locations. May be used as a weatherproof junction box, or as a housing for receptacles, switches and GFCI s. Reinforced connector outlets State-of-the-art powder coat finish Eight box mounting options with detachable lugs provided Two closure plugs included Ground screw installed Multi-lingual instructions in each package Internal threads on hubs comply with NEMA requirements. Hubs accept all threaded fittings and threaded conduit. File E C22.2 No. 18 NEMA 3R Rated , , to , , , , , SEE End of SECTION (PG D34) FOR DETAILED DRAWINGS» CATALOG # CUBIC In. Description (cm 3 ) COLOR OUTLETS Pkg. Type STD. PKG. BARCODE 2" Deep, with Lugs Three Threaded Outlets 4-1/2" X 4-1/2" (524.4) Gray (3) 1/2" Shrink 12 IIIIIIII (524.4) Gray (3) 3/4" Shrink 12 IIIIIIII 2" Deep, with Lugs Four Threaded Outlets 4-1/2" X 4-1/2" (508.0) Gray (4) 1/2" Shrink 12 IIIIIIII (508.0) Gray (4) 3/4" Shrink 12 IIIIIIII 2" Deep, with Lugs Five Threaded Outlets 4-1/2" X 2-3/4" (508.0) Gray (5) 1/2" Shrink 12 IIIIIIII (508.0) White (5) 1/2" Shrink 12 IIIIIIII (508.0) Gray (5) 1/2" Carded 4 IIIIIIII (508.0) Gray (5) 3/4" Shrink 12 IIIIIIII (524.4) Gray (5) 1/2" Shrink 12 IIIIIIII (524.4) Gray (5) 3/4" Shrink 12 IIIIIIII 2" Deep, with Lugs Seven Threaded Outlets 4-1/2" X 4-1/2" (494.9) Gray (7) 1/2" Shrink 12 IIIIIIII (494.9) Gray (7) 3/4" Shrink 12 IIIIIIII (508.0) Gray (7) 1/2" Shrink 12 IIIIIIII (508.0) Gray (7) 3/4" Shrink 12 IIIIIIII 2-5/8" Deep, with Lugs Five Threaded Outlets 4-1/2" X 4-1/2" (589.9) Gray (5) 3/4" Shrink 9 IIIIIIII (589.9) Gray (5) 1" Shrink 9 IIIIIIII D6 BELL WEATHERPROOF
7 DIE CAST MULTI-GANG BOXES AND EXTENSIONS Two-Gang Extension CATALOG # Cubic In. Description Pkg. TyPE Std. PKG. Barcode (cm 3 ) Color Outlets Two-Gang Extension 4-21/32" X 4-21/32" X 1-1/32" Deep (262.2) Gray Shrink 10 IIIIIIII Application Used to provide additional capacity needed for NEC box fill requirements. Rugged seamless construction State-of-the-art powder coat finish Installation hardware and gasket provided Multi-lingual instructions in each package File E C22.2 No. 18 NEMA 3R Rated Three-Gang Box CATALOG # Cubic In. Description Pkg. TyPE Std. PKG. Barcode (cm 3 ) Color Outlets Three-Gang Box 2-5/8" Deep, with Lugs Seven Threaded Outlets 4-1/2" X 6-3/8" (901.3) Gray (7) 3/4" Boxed 1 IIIIIIII Applications For use in branch circuit wiring in wet, damp or dry locations. Can be used as a weatherproof junction box, or as a housing for receptacles, switches and GFCI s. Seamless die cast aluminum construction Reinforced connector outlets State-of-the-art powder coat finish Eight box mounting options with de-tachable lugs provided Four closure plugs included Ground screws installed Multi-lingual instructions in each package Internal threads and hubs comply with NEMA requirements. Hubs accept all threaded fittings and threaded conduit. File E C22.2 No. 18 NEMA 3R Rated SEE End of Section (PG D35) for Detailed drawings» D7
8 DIE CAST ALUMINUM ROUND SPLICE BOXES AND EXTENSION ADAPTERS Applications For use in branch circuit wiring in wet, damp or dry locations. Designed for use as a weatherproof junction box, and may be used with BELL round cluster covers and round lampholder combinations. Rugged die cast construction Reinforced connector outlets State-of-the-art powder coat finish Cast-in mounting lugs provide fast, secure installation Includes four closure plugs, installed ground screw and multi-lingual instructions. File E C22.2 No. 18 NEMA 3R Rated 4" Round Box to , CATALOG # CUBIC In. Description (cm 3 ) COLOR OUTLETS Pkg. Type STD. PKG. BARCODE 4" Round Splice Box Five Threaded Outlets 1-1/2" Deep (262.2) Gray (5) 1/2" Shrink 16 IIIIIIII (262.2) White (5) 1/2" Shrink 16 IIIIIIII (262.2) Bronze (5) 1/2" Shrink 16 IIIIIIII (262.2) Gray (5) 1/2" Carded 6 IIIIIIII (262.2) White (5) 1/2" Carded 6 IIIIIIII (262.2) Bronze (5) 1/2" Carded 6 IIIIIIII (262.2) Gray (5) 3/4" Shrink 16 IIIIIIII Applications For use with 4" round splice boxes Extension adapters are used to in-crease box capacity and allow the installer to add take-offs to new boxes/devices. Rugged die cast construction Reinforced connector outlets State-of-the-art powder coat finish Includes installation hardware, closure plugs, gasket and multi-lingual instructions. File E C22.2 No. 18 NEMA 3R Rated ROUND EXTENSION ADAPTERS CATALOG # CUBIC In. Description Pkg. Type STD. PKG. BARCODE (cm 3 ) COLOR OUTLETS 4" Round Extension Adapter Four Threaded Outlets 1-1/2" Deep (267.1) Gray (4) 1/2" Shrink 16 IIIIIIII SEE End of SECTION (PG D35) FOR DETAILED DRAWINGS» D8 BELL WEATHERPROOF
9 ROUND Blank Covers Round Box COVERS CATALOG # DESCRIPTION COLOR OUTLETS Pkg. Type STD. PKG. BARCODE 4" Round Cover Gray Shrink 30 IIIIIIII Application For use with 4" round splice boxes Rugged metallic construction State-of-the-art powder coat finish Includes installation hardware, gasket and multi-lingual instructions. File E C22.2 No. 18 NEMA 3R Rated SEE End of SECTION (PG D36) FOR DETAILED DRAWINGS» D9
10 DUTY RaynGuard Extra Duty While-In-Use Metallic Covers Application The RaynGuard Extra Duty Metallic While-In-Use covers are designed for use whenever protection is required while an outlet is in use. Superior commercial quality die-cast aluminum Meets or exceeds Extra Duty rating in UL 514D Contractor surveyed and prefered for exact application - no plates to assemble NEMA 3R rated / Patent Pending Added rain chamber for extra protection from splashing Provision on each side for holding cords - No pull-outs Padlockable - Accepts standard size padlocks Includes gasket and hardware Powder coated for corrosion protection Unique lid design allows larger plugs and provides more room for bend radius of electrical cords Device or box mounting File E NEMA 3R Rated Meets NEC (B) Requirements U.S. Patent 8,013, EXTRA DUTY CATALOG # DESCRIPTION Depth COLOR PKG. Type STD. PKG. BARCODE 1-Gang Extra Duty While-In-Use Covers Vertical GFCI 3" Gray Shrink 4 IIIIIIII Horizontal GFCI 3" Gray Shrink 3 IIIIIIII Vertical Duplex 3" Gray Shrink 4 IIIIIIII Horizontal Duplex 3" Gray Shrink 3 IIIIIIII 1-Gang Extra Duty Deep While-In-Use Covers Vertical 1.55" or 2.10" Single Round 4.5" Gray Shrink 3 IIIIIIII 2-Gang Extra Duty While-In-Use Covers (2) GFCI 3" Gray Shrink 3 IIIIIIII (2) Duplex 3" Gray Shrink 3 IIIIIIII GFCI/Duplex 3" Gray Shrink 3 IIIIIIII SEE End of SECTION (PG D36) FOR DETAILED DRAWINGS» D10 BELL WEATHERPROOF
11 Metal SINGLE-GANG DEVICE COVERS I + or = Adapter (Included) Duplex Switch MX1050S, Z, W 1 1/4" 1 3/8" 1 9/16" & 1 5/8" GFCI GFCI + or = Adapter (Included) Duplex Multi-Configuration MX1250S, Z, W Duplex Switch Switch 1 1/4" 1 1/4" 1 3/8" + = Adapter (Included) 1 3/8" 1 9/16" & 1 5/8" Duplex Duplex GFCI Switch Duplex GFCI Switch 1 1/4" 1 3/8" 1 9/16" & 1 5/8" GFCI 1 9/16" & 1 5/8" Switch Applications For use whenever weatherproof protection is required for an outdoor receptacle or switch. Product FEATuRES Heavy duty die-cast metal construction Patented Quick-Fit keyhole mounting system allows cover installation in under a minute Includes gasket and mounting hardware Base configuration with patented Knock-Out technology for custom fitting Premium powdercoat finish Horizontal or vertical mount Lockable tab ComPLIANCES 1 1/4" 1 3/8" File E NEMA 3R Rated 1 9/16" & 1 5/8" Meets NEC (B) Requirements U.S. Patent 8,013, /4" 1 3/8" 1 9/16" & 1 5/8" + = Adapter Duplex GFCI (Included) + = Switch lex GFCI Switch 1 1/4" 1 3/8" 1 9/16" Configurations GFCI & 1 5/8" Adapter (Included) 1 1/4" 1 3/8" 1 9/16" & 1 5/8" Switch 1 1/4" 1 3/8" 1 9/16" & 1 5/8" 1 3/4" 2 1/8" GFCI Switch 1 1/4" 1 3/8" 1 9/16" 1 3/4" 2 1/8" & 1 5/8" MX1550S 1-Gang Flip Covers MX1050S Vertical/Horizontal Gray Shrink 20 IIIIIIII MX1050Z Vertical/Horizontal Bronze Shrink 20 IIIIIIII MX1050W Vertical/Horizontal White Shrink 20 IIIIIIII MX1250S Horizontal/Vertical Gray Shrink 20 IIIIIIII MX1250Z Horizontal/Vertical Bronze Shrink 20 IIIIIIII MX1250W Horizontal/Vertical White Shrink 20 IIIIIIII MX1550S Vertical/Horizontal Twist Lock Cover Gray Shrink 10 IIIIIIII SEE End of SECTION (PG D38) FOR DETAILED DRAWINGS» D11
12 metal SINGLE-GANG DEVICE COVERS Application For use whenever weatherproof protection is required for an outdoor receptacle. Rugged die cast construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance. Self-closing lids assure weatherproof protection when the receptacle is not in use Vertical mount covers are padlockable May be mounted to box or device Includes installation hardware, gasket, and multi-lingual instruction File E C22.2 No. 18 NEMA 3R Rated DIE CAST ALUMINUM RAYNTITE to , Vertical Mount Padlockable Single, 1.593" diameter Gray Shrink 24 IIIIIIII Duplex Gray Shrink 24 IIIIIIII GFCI Gray Shrink 24 IIIIIIII GFCI Gray Carded 6 IIIIIIII GFCI White Carded 6 IIIIIIII A, 1.710" diameter Gray Shrink 12 IIIIIIII A, 2.150" diameter Gray Shrink 12 IIIIIIII Single, 1.406" diameter Gray Shrink 12 IIIIIIII Horizontal Mount Duplex Gray Shrink 24 IIIIIIII GFCI Gray Shrink 24 IIIIIIII SEE End of SECTION (PG D38) FOR DETAILED DRAWINGS» D12 BELL WEATHERPROOF
13 metal SINGLE-GANG DEVICE COVERS to Vertical Flip Covers to Application For use whenever weatherproof protection is required for an outdoor receptacle. Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance Self-closing lids assure weatherproof protection when the receptacle is not in use. Includes installation hardware, gasket and multi-lingual instructions File E NEMA 3R Rated to Device Mount Duplex Gray Shrink 24 IIIIIIII Duplex White Shrink 24 IIIIIIII Duplex Gray Carded 6 IIIIIIII Duplex Gray Shrink 24 IIIIIIII GFCI Gray Shrink 24 IIIIIIII GFCI White Shrink 24 IIIIIIII GFCI Bronze Shrink 24 IIIIIIII GFCI Gray Carded 6 IIIIIIII GFCI White Carded 6 IIIIIIII GFCI Bronze Carded 6 IIIIIIII GFCI Gray Shrink 24 IIIIIIII Single, 1.406" diameter Gray Shrink 24 IIIIIIII Single, 1.406" diameter White Shrink 24 IIIIIIII Single, 1.406" diameter Gray Carded 6 IIIIIIII Single, 1.406" diameter White Carded 6 IIIIIIII Box Mount Duplex Gray Shrink 24 IIIIIIII Single, 1.406" diameter Gray Shrink 24 IIIIIIII SEE End of SECTION (PG D38) FOR DETAILED DRAWINGS» D13
14 metal SINGLE-GANG DEVICE COVERS Application For use whenever weatherproof protection is required for an outdoor receptacle. Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance. Self-closing lids assure weatherproof protection when the receptacle is not in use. Includes installation hardware, gasket and multi-lingual instructions File E Certified C22.2 No. 18 NEMA 3R Rated Horizontal Flip Covers to to Device Mount Duplex Gray Shrink 24 IIIIIIII Duplex White Shrink 24 IIIIIIII Duplex Bronze Shrink 24 IIIIIIII Duplex Gray Carded 6 IIIIIIII Duplex White Carded 6 IIIIIIII Duplex Bronze Carded 6 IIIIIIII Duplex Gray Shrink 24 IIIIIIII * GFCI Gray Shrink 24 IIIIIIII * GFCI White Shrink 24 IIIIIIII * GFCI Bronze Shrink 24 IIIIIIII * GFCI Gray Carded 6 IIIIIIII * GFCI White Carded 6 IIIIIIII * GFCI Bronze Carded 6 IIIIIIII GFCI Gray Shrink 24 IIIIIIII Single, 1.406" diameter Gray Shrink 24 IIIIIIII Motor plug base, 1.600" diameter, 125V, 15A wiring device included Gray Shrink 12 IIIIIIII * 125V, 15A Duplex receptacle included Gray Carded 6 IIIIIIII Box Mount Duplex Shrink 24 Gray IIIIIIII * C/UL Listed SEE End of SECTION (PG D39) FOR DETAILED DRAWINGS» D14 BELL WEATHERPROOF
15 metal two-gang DEVICE COVERS = No adapter required for these configurations MX2050S, Z, WH Double GFCI + = Adapter (Included) GFCI / Duplex Duplex / GFCI 1 1/4" 13/8" Multi-Configuration + = Adapter (Included) 1 1/4" 13/8" 1 1/4" 13/8" 1 1/4" 13/8" 25 IN 1 CONFIGURATIONS CONFIGURACIONES + or = 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 3/8" 1 3/8" 1 1/4" 1 3/8" Applications For use whenever weatherproof protection is required for an outdoor receptacle or switch. 1 1/4" 1 3/8" 1 3/8" 1 3/8" Product FEATuRES Heavy duty die-cast metal construction Patented Quick-Fit keyhole mounting system allows cover installation in under a minute. Includes gasket and mounting hardware Base configuration with patented Knock-Out technology for custom fitting Premium powdercoat finish Horizontal or vertical mount Lockable tab ComPLIANCES File E NEMA 3R Rated U.S. Patents: 8,314,334; D 569,811 Adapter (Included) 2 1/4" Duplex GFCI MX2150S 2-Gang Flip Covers MX2050S 2-Device 25-in-1 Gray Shrink 8 IIIIIIII MX2050Z 2-Device 25-in-1 Bronze Shrink 4 IIIIIIII MX2050WH 2-Device 25-in-1 White Shrink 4 IIIIIIII MX2150S 1-Device 3-in-1 Gray Shrink 6 IIIIIIII SEE End of SECTION (PG D39) FOR DETAILED DRAWINGS» D15
16 metal two-gang DEVICE COVERS Application For use whenever weatherproof protection is required for an outdoor receptacle. Rugged die cast construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance. Self-closing lids assure weatherproof protection when the receptacle is not in use. Covers are padlockable, 1/4" dia. hole May be mounted to box or device Includes installation hardware, gasket and multi-lingual instructions File E C22.2 No. 18 NEMA 3R Rated DIE CAST ALUMINUM RAYNTITE Vertical Mount Padlockable (2) Duplex Gray Shrink 6 IIIIIIII (1) Duplex & (1) GFCI Gray Shrink 6 IIIIIIII (1) 30-50A Receptacle 2.625" diameter Gray Shrink 6 IIIIIIII (1) 30-50A Receptacle 2.156" diameter Gray Shrink 6 IIIIIIII (2) Receptacles, 1.406" diameter Gray Shrink 6 IIIIIIII (1) Single Receptacle, 1.406" diameter & (1) GFCI Gray Shrink 6 IIIIIIII (2) Toggle Gray Shrink 6 IIIIIIII (1) Toggle & (1) Duplex Gray Shrink 6 IIIIIIII (1) Toggle & (1) GFCI Gray Shrink 6 IIIIIIII (2) GFCI Gray Shrink 6 IIIIIIII SEE End of SECTION (PG D40) FOR DETAILED DRAWINGS» D16 BELL WEATHERPROOF
17 metal two-gang DEVICE COVERS Application For use whenever weatherproof protection is required for an outdoor receptacle to Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance. Self-closing lids assure weatherproof protection when the receptacle is not in use. Includes installation hardware, gasket and multi-lingual instructions File E File E (# #5145) C22.2 (# #5145) NEMA 3R Rated Device Mount (2) Duplex Gray Shrink 10 IIIIIIII (2) Round, 1.406" Dia. Gray Shrink 10 IIIIIIII (2) Duplex Gray Shrink 18 IIIIIIII (2) Duplex Gray Carded 4 IIIIIIII (2) Single, 1.406" dia. Gray Shrink 18 IIIIIIII (1) Duplex & (1) Single, 1.406" dia. Gray Shrink 12 IIIIIIII Box Mount (2) Duplex Gray Shrink 12 IIIIIIII (2) Single, 1.406" dia. Gray Shrink 12 IIIIIIII (1) Duplex & (1) Single, 1.406" dia. Gray Shrink 12 IIIIIIII (1) Duplex, (1) GFCI Gray Shrink 10 IIIIIIII (2) GFCI Gray Shrink 10 IIIIIIII SEE End of SECTION (PG D40) FOR DETAILED DRAWINGS» D17
18 metal three-gang DEVICE COVERS Applications For use whenever weatherproof protection is required for an outdoor receptacle or switch. Product FEATuRES Heavy duty die-cast metal construction Patented Quick-Fit keyhole mounting system allows cover installation in under a minute. Includes gasket and mounting hardware Base configuration with patented Knock-Out technology for custom fitting. Premium powdercoat finish Horizontal or vertical mount Lockable tab ComPLIANCES File E NEC compliant NEMA 3R rated multi-configuration covers MX3050S Multi-Configuration 3-Gang Flip Covers MX3050S 3-Device 125-in-1 Gray Shrink 5 IIIIIIII Applications For use whenever weatherproof protection is required for an outdoor receptacle. Blank covers for use whenever weatherproof protection is required for a multi-gang box Box Mount Flip covers Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance Self-closing lids assure weatherproof protection when the receptacle is not in use Includes installation hardware, gasket, and multi-lingual instructions File E NEMA 3R Rated Gang Flip Covers (3) Duplex Gray Boxed 1 IIIIIIII (3) Single, 1.406" dia. Gray Boxed 1 IIIIIIII SEE End of SECTION (PG D41) FOR DETAILED DRAWINGS» D18 BELL WEATHERPROOF
19 complete Device Kits Flip Cover Kits to to Application For use in wet, damp, or dry locations Each kit is a convenient, complete weatherproof installation no need to purchase separate components Easy to follow multi-lingual instructions included File E File E (5874 Series) MK1250S, WH Complete Flip Cover Kits Duplex Gray Box 4 IIIIIIII WRTR WRTR Duplex Gray Box 4 IIIIIIII Duplex White Box 4 IIIIIIII WRTR WRTR Duplex White Box 4 IIIIIIII Duplex Bronze Box 4 IIIIIIII WRTR WRTR Duplex Bronze Box 4 IIIIIIII GFCI Gray Box 4 IIIIIIII GFCI White Box 4 IIIIIIII MK1250S Duplex Gray Clamshell 4 IIIIIIII MK1250WH Duplex White Clamshell 4 IIIIIIII SEE End of SECTION (PG D41) FOR DETAILED DRAWINGS» D19
20 metal Blank Covers Application For use whenever weatherproof protection is required for a weatherproof box. Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance File E NEMA 3R Rated to TO One-Gang Blank Covers - Device Mount Blank Cover Gray Shrink 50 IIIIIIII Blank Cover White Shrink 50 IIIIIIII Blank Cover Bronze Shrink 50 IIIIIIII Blank Cover Gray Carded 12 IIIIIIII Blank Cover White Carded 12 IIIIIIII Blank Cover Bronze Carded 12 IIIIIIII One-Gang Blank Covers - Box Mount Blank Cover Gray Shrink 50 IIIIIIII Two-Gang Blank Covers - Device Mount Blank Cover Gray Shrink 25 IIIIIIII Blank Cover White Shrink 25 IIIIIIII Blank Cover Bronze Shrink 25 IIIIIIII Blank Cover Gray Carded 6 IIIIIIII Three-Gang Blank Covers - Box Mount Blank Cover Gray Boxed 10 IIIIIIII SEE End of SECTION (PG D42) FOR DETAILED DRAWINGS» D20 BELL WEATHERPROOF
21 metal TOGGLE switch Covers Application For use whenever weatherproof protection is required for an "on-off type switch to to , Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratch resistance. Includes installation hardware and multilingual instructions Most units supplied with a switch(es) no need to purchase separate components Switch/cover units are supplied with the switch unassembled to the cover to File E Certified NEMA 3R Rated Single-Gang Switch Covers Vertical Device Mounted SP 125V, 10A Gray Shrink 24 IIIIIIII SP 125V, 10A White Shrink 24 IIIIIIII SP 125V, 10A Bronze Shrink 24 IIIIIIII SP 125V, 10A Gray Carded 6 IIIIIIII Way 125V, 6A or 250V, 3A Gray Shrink 8 IIIIIIII Way 125V, 6A or 250V, 3A Gray Carded 6 IIIIIIII SP VAC, 20A Gray Shrink 20 IIIIIIII DP VAC, 20A Gray Shrink 20 IIIIIIII Two-Gang Switch Covers Device Mounted (2) SP 125V, 10A Gray Shrink 8 IIIIIIII Cover only Gray Shrink 8 IIIIIIII (1) SP 125V, 10A & (1) Duplex receptacle Gray Shrink 8 IIIIIIII (1) SP 125V, 10A & (1) Duplex receptacle Gray Carded 4 IIIIIIII Gang, Switch/GFCI Cover box mount Gray Shrink 8 IIIIIIII Three-Gang Switch Cover Device Mount (3) SP 125V, 10A Gray Boxed 1 IIIIIIII Toggle Switch SP 125V, 10A Toggle switch Polybag 10 IIIIIIII SEE End of SECTION (PG D42) FOR DETAILED DRAWINGS» D21
22 DIE CAST lampholder/cluster covers Applications For use with BELL single-gang rectangular or round weather-proof boxes. Cluster covers provide an easy means of mounting BELL lampholders and other accessories. Rugged die cast construction State-of-the-art powder coat finish provides maximum weatherability and scratchresistance. Includes installation hardware, gasket and multi-lingual instructions Three-hole covers are supplied with two closure plugs. Standard 514A Certified - C22.2 # to to to to Rectangular Cluster Covers /2" Outlet Gray Shrink 20 IIIIIIII /2" Outlet White Shrink 20 IIIIIIII /2" Outlet Bronze Shrink 20 IIIIIIII /2" Outlet Gray Carded 6 IIIIIIII /2" Outlet White Carded 6 IIIIIIII /2" Outlet Bronze Carded 6 IIIIIIII /2" Outlets Gray Shrink 20 IIIIIIII /2" Outlets White Shrink 20 IIIIIIII /2" Outlets Bronze Shrink 20 IIIIIIII /2" Outlets Gray Carded 6 IIIIIIII /2" Outlets White Carded 6 IIIIIIII /2" Outlets Bronze Carded 6 IIIIIIII 4" Round Cluster Covers /2" Outlet Gray Shrink 20 IIIIIIII /2" Outlet White Shrink 20 IIIIIIII /2" Outlet Bronze Shrink 20 IIIIIIII /2" Outlet Gray Carded 6 IIIIIIII /2" Outlet White Carded 6 IIIIIIII /2" Outlet Bronze Carded 6 IIIIIIII /2" Outlets Gray Shrink 20 IIIIIIII /2" Outlets White Shrink 20 IIIIIIII /2" Outlets Bronze Shrink 20 IIIIIIII /2" Outlets Gray Carded 6 IIIIIIII /2" Outlets White Carded 6 IIIIIIII /2" Outlets Bronze Carded 6 IIIIIIII SEE End of SECTION (PG D43) FOR DETAILED DRAWINGS» D22 BELL WEATHERPROOF
23 DIE cast lampholders Lampholders and Accessories for Watt Par 38 Lamps Lampholder Gray Shrink 30 IIIIIIII Lampholder White Shrink 30 IIIIIIII Lampholder Bronze Shrink 30 IIIIIIII Lampholder Gray Carded 6 IIIIIIII Lampholder White Carded 6 IIIIIIII Lampholder Bronze Carded 6 IIIIIIII Lampholder w/gasket Gray Shrink 30 IIIIIIII Outer gasket only, replacement gasket for Polybag 15 IIIIIIII Wire guard only Shrink 5 IIIIIIII Architectural Lampholders for Watt Par 38 Lamps Lampholder Gray Shrink 4 IIIIIIII Lampholder White Shrink 4 IIIIIIII Lampholder Bronze Shrink 4 IIIIIIII Halogen LHS100S, W, Z to Multi-Directional Swivel Joint Swivel Joint Lampholders NO TOOL EASY MOUNT FEATURE LTS100S, WH, Z CFL Compatible CATALOG # DESCRIPTION COLOR PKG. Type STD. PKG. Barcode Halogen Swivel Lampholder LHS100S 75W Halogen Bulb Included (GY 8.6 TYPE 4) Gray Shrink 6 IIIIIIII LHS100W 75W Halogen Bulb Included (GY 8.6 TYPE 4) White Shrink 6 IIIIIIII LHS100Z 75W Halogen Bulb Included (GY 8.6 TYPE 4) Bronze Shrink 6 IIIIIIII Traditional or CFL Swivel Lampholder LTS100S Uses Par 38 Bulb (150W Maximum, Not Included) Gray Shrink 10 IIIIIIII LTS100WH Uses Par 38 Bulb (150W Maximum, Not Included) White Shrink 10 IIIIIIII LTS100Z Uses Par 38 Bulb (150W Maximum, Not Included) Bronze Shrink 10 IIIIIIII Applications For outdoor or indoor lighting use May be used with BELL cluster covers and boxes. Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratchresistance. Locking swivel knuckle assures positive lamp positioning and provides pin-point directional aiming. Extra long wire leads for easy hook-up Each lampholder supplied with a porcelain socket, inside gasket, 1/2" locknut and multi-lingual instructions. Standard 1598 Certified C22.2 No. 18 Applications For general outdoor lighting use in wet, damp or dry locations. Product FEATuRES Superior commercial quality die-cast metal construction Premium powdercoat finish LTS100 include porcelain sockets and external weatherproof gaskets are CFL compatible. LHS uses halogen bulb which compared to incandescent bulbs, last up to 3 times longer and produce almost 50% more light for the same amount of energy. Patented no-tool easy-mount feature Patented swivel joint for easy directional lighting. ComPLIANCES File E NEC compliant NEMA 3R Rated U.S. Patent 7,695,170 SEE End of SECTION (PG D43) FOR DETAILED DRAWINGS» D23
24 Metal Bullet Lampholder and Portable Lampholders Application For general outdoor lighting use May be used with BELL cluster covers and boxes. Rugged die cast Locking swivel knuckle Assure positive lamp positioning and provides pinpoint directional aming Includes installation hardware and multilingual instructions C US Bullet Lampholders - for Watt Par 38 and R-40 Lamps Green Lampholder Boxed 2 IIIIIII Applications For general outdoor lighting use in wet, damp or dry locations. Product FEATuRES Rugged die-cast construction State-of-the-art powder coat finish provides maximum weatherability and scratchresistance. Locking swivel knuckle assures positive lamp positioning and provides pin-point directional aiming. SPLED2Z Long Lasting Energy Efficient 6.5 Watts/350 Lumens ComPLIANCES File E (SL101B) 2014 NEC compliant NEMA 3R rated Portable Lampholders CFL Compatible SL101B LED SPLED2Z Portable Spike Lights SPLED2Z LED Bulb Included (350 Lumens) Bronze Clamshell 4 IIIIIIII SL101B Uses Par 38 Bulb (150W Maximum, Not Included) Bronze Clamshell 10 IIIIIIII Spike, 6 ft. cord & plug Gray Polybag 12 IIIIIIII SEE End of SECTION (PG D44) FOR DETAILED DRAWINGS» D24 BELL WEATHERPROOF
25 Die Cast Lampholder combinations to to to Application For use with BELL single-gang rectangular or round weatherproof boxes. Rugged metallic construction State-of-the-art powder coat finish provides maximum weatherability and scratchresistance. Each combination kit is a complete weatherproof installation no need to purchase separate components. Includes installation hardware, gasket and multi-lingual instructions File E Certified C22.2 No. 18 Rectangular Cover Combinations for Watt Par 38 Lamps (1) Lampholder Gray Shrink 8 IIIIIIII (2) Lampholders Gray Shrink 8 IIIIIIII (2) Lampholders Gray Carded 4 IIIIIIII (2) Lampholders White Carded 4 IIIIIII 4" Round Cover Combinations for Watt Par 38 Lamps (1) Lampholder Gray Shrink 8 IIIIIIII (1) Lampholder White Shrink 8 IIIIIIII (1) Lampholder Bronze Shrink 8 IIIIIIII (1) Lampholder Gray Carded 4 IIIIIII (1) Lampholder White Carded 4 IIIIIIII (2) Lampholders Gray Shrink 8 IIIIIIII (2) Lampholders White Shrink 8 IIIIIIII (2) Lampholders Bronze Shrink 8 IIIIIII (2) Lampholders Gray Carded 4 IIIIIIII (2) Lampholders White Carded 4 IIIIIIII (2) Lampholders Bronze Carded 4 IIIIIIII SEE End of SECTION (PG D45) FOR DETAILED DRAWINGS» D25
26 Light Kits Application For general use in wet, damp or dry locations. Each kit is a complete weatherproof installation no need to purchase separate components. Each kit includes easy-to-follow multilingual instructions. All kit components are described in the preceding pages to to to to Rectangular Light Kits for Watt Par 38 Lamps Box, cover, photocell & (2) lampholders Gray Boxed 4 IIIIIIII Box, cover, photocell & (2) lampholders White Boxed 4 IIIIIIII Box, cover & (2) lampholders Gray Boxed 4 IIIIIIII Box, cover & (2) lampholders White Boxed 4 IIIIIIII 4" Round Light Kits for Watt Par 38 Lamps Box, cover & (2) lampholders Gray Boxed 4 IIIIIIII Box, cover & (2) lampholders White Boxed 4 IIIIIIII Box, cover, photocell & (2) lampholders Gray Boxed 4 IIIIIIII Box, cover, photocell & (2) lampholders White Boxed 4 IIIIIIII Box, cover & (2) architectural lampholders Gray Boxed 4 IIIIIIII Box, cover & (2) architectural lampholders White Boxed 4 IIIIIIII Box, cover & (2) architectural lampholders Bronze Boxed 4 IIIIIIII D26 BELL WEATHERPROOF
27 metallic Garden Lights Application For accent lighting along walkways, driveways, terraces, porches and garden areas. Rugged die cast construction State-of-the-art powder coat finish provides maximum weatherability and scratchresistance. Includes screw-in clear glass globe, wire connectors, gasket, and multi-lingual instructions Three-tier lights accept 40W maximum lamps Four-tier lights accept 60W maximum lamps Incandescent Type Threaded 1/2" Npt - 18" Leads Tier Green Box 2 IIIIIIII Tier Green Box 2 IIIIIIII Replacement Globes for Garden For 3-tier Clear Carton 4 IIIIIIII For 4-tier Clear Carton 4 IIIIIIII SEE End of SECTION (PG D45) FOR DETAILED DRAWINGS» D27
28 accessories Application Used for darkness activated automatic control of night lighting from dusk to dawn. Switch may be used to control porch lights, garden lights, post lanterns, barn lights, loading dock lights, outdoor signs and the like. Durable weatherproof construction Built-in time delay prevents operation triggered by auto headlamps or other temporary light flashes. photocell PE100 Photoelectric Eye Switch Swivel Switch, locknut 2000W Tungsten 1800VA Ballast Gray Carded 6 IIIIIIII 120V 50-60HZ PE100 Outdoor Photoelectric Switch Rated 1000 Watts, Fits 1/2 Hole Black Poly Bag 20 IIIIIIII Application For use with BELL weatherproof boxes, extension adapters, cluster covers and round splice boxes to seal off unused outlets. Product Feature Gray closure plugs are zinc die cast White and bronze closure plugs are nonmetallic File E metal CLOSURE PLUGS to , to , Closure Plugs /2" NPT Gray 75 Polybags of 4 75 bags* IIIIIIII /2" NPT White 75 Polybags of 4 75 bags* IIIIIIII /2" NPT Bronze 75 Polybags of 4 75 bags* IIIIIIII /2" NPT Gray 12 Cards of 3 12 cards** IIIIIIII /2" NPT White 12 Cards of 3 12 cards** IIIIIIII /2" NPT Bronze 12 Cards of 3 12 cards** IIIIIIII /2" NPT Gray Bulk /2" NPT Bronze Bulk /4" NPT Gray 75 Polybags of 4 75 bags* IIIIIIII /4" NPT White 75 Polybags of 4 75 bags* IIIIIIII /4" NPT Gray 12 Cards of 3 12 cards** IIIIIIII /4" NPT Gray Bulk " NPT Gray 75 Polybags of 4 75 bags* IIIIIIII *Order in standard package bag quantities only not per piece **Order in standard package card quantities only not per piece SEE End of SECTION (PG D46) FOR DETAILED DRAWINGS» D28 BELL WEATHERPROOF
29 accessories Box Mounting Lugs Box Mounting Lugs & Screws Polybags of ROUND CLOSURE PLATES Application Use in dry locations for closure of unused ceiling outlets. Rugged metallic construction State-of-the-art powder coat paint finish provides a scratch-resistant surface. File E " Round Closure Plates Steel Screw & universal mount strap Off White Shrink 10 IIIIIIII (2) 8-32 screws, direct mount to fixture outlet box Off White Shrink 10 IIIIIIII Fixture stud & universal mount strap Off White Shrink 10 IIIIIIII REPLACEMENT GASKETS Application Replacement gaskets for BELL weatherproof covers and lampholders Each gasket has cut outs for a toggle switch, duplex receptacle and 1.406" dia. round receptacle. Remove the cut outs for the duplex and round receptacles for a GFCI receptacle opening. Rectangular Box/Cover Gaskets Gang Black 20 Cello bags of 2 20 IIIIIIII Gang Black 20 Cello bags of 2 20 IIIIIIII Gang cover gasket, 4 Lampholder gaskets Black 20 Cello bags 20 IIIIIIII SEE End of SECTION (PG D46) FOR DETAILED DRAWINGS» D29
30 Non-metallic Boxes Outlet Boxes APPLICATIONS For general use whenever weatherproof protection is required. PRODuCT features Durable high impact PVC construction Can be used for 1/2" and 3/4" conduit Includes 3/4" closure plugs and reducer bushings ComPLIANCES Marine 2014 NEC compliant NEMA 3R rated x2 PSB37550GY PSB37550WH x3 x6 PDB77550GY PDB77550WH x7 x4 x5 PRB57550GY PRB57550WH CATALOG # description Cu. In. (cm 3 ) Color PKG. TyPE Std. PKG. Barcode 1-Gang Outlet Boxes PSB37550GY Three 1/2" or 3/4" Holes 2.0" Depth 16.5 (270.4) Gray Shrink 8 IIIIIIII PSB37550WH Three 1/2" or 3/4" Holes 2.0" Depth 16.5 (270.4) White Shrink 5 IIIIIIII 2-Gang Outlet Boxes PDB77550GY Seven 1/2" or 3/4" Holes 2.0" Depth 26.5 (270.4) Gray Shrink 6 IIIIIIII PDB77550WH Seven 1/2" or 3/4" Holes 2.0" Depth 26.5 (434.3) White Shrink 6 IIIIIIII Round Outlet Box PRB57550GY Five 1/2" / 3/4" Holes 1.125" Depth 13.5 (221.2) Gray Shrink 8 IIIIIIII PRB57550WH Five 1/2" / 3/4" Holes 1.125" Depth 13.5 (221.2) White Shrink 8 IIIIIIII SEE End of Section (PG D47) for Detailed drawings» D30 BELL WEATHERPROOF
31 PBC100GY PBC100WH CONFIGURATIONS BELL WEATHERPROOF BOXES, COVERS AND LIGHTING + = CONFIGURACIONES Adapters (Included) GFCI Switch 1-1/4" 1-3/8" 1-9/16" Adaptadores (Incluído) 1 & 1-5/8" + = Non-metallic 8 Covers 2-1/4" 1 Adapters (Included) GFCI Switch 1-1/4" 1-3/8" 1-9/16" 1-3/4" 2-1/8" Without Adapter Adaptadores (Incluído) & 1-5/8" Sin Adaptadore Blank Covers 8 in 1 in APPLICATIONS For general use whenever CONFIGURATIONS weatherproof protection is required. CONFIGURACIONES Product FEATuRES + = CONFIGURATIONS Durable high impact polycarbonate CONFIGURACIONES Adapters (Included) GFCIconstruction Switch 1-1/4" 1-3/8" 1-9/16" Adaptadores (Incluído) 1 & 1-5/8" Includes attached gasket and mounting + = hardware 2-1/4" Adapters (Included) 8 1 GFCI Switch 1-1/4" 1-3/8" 1-9/16" 1-3/4" 2-1/8" Without Adapter Adaptadores (Incluído) ComPLIANCES & 1-5/8" Sin Adaptadore 8 in 2014 NEC compliant PBC200GY NEMA 3R rated PBC300GY PBC200WH PBC300WH in 1CONFIGURATIONS CONFIGURACIONES RECEPTACLE COVERS CONFIGURATIONS + = Patented Horseshoe Adapter Ensures a Snug Fit CONFIGURACIONES for Small and Large Head Switches GFCI + = Adapters (Included) Adaptadores (Incluído) Switch GFCI 1-1/4" 1-3/8" 1-9/16" & 1-5/8" Adapters (Included) Adaptadores (Incluído) Switch 1-3/4" 2-1/8" Wi Si PTC100GY PTC100WH PTC200GY 1-3/8" 1-9/16" & 1-5/8" 1-3/4" 2-1/8" CONFIGUR 8 IN CONFIGUR 1 CONFIGURATIONS CONFIGURACIONES or + = CONFIGURACIONES PTC521GY PTC521WH 2-1/4" Without Adapter Sin Adaptadore Adapters (Included) Adaptadores (Incluído) or + = Adapters (Included) Adaptadores (Incluído) Blank Covers PBC100GY Blank Gray Shrink 12 IIIIIIII PBC100WH Blank White Shrink 12 IIIIIIII PBC200GY Blank 2-Gang Gray Shrink 10 IIIIIIII PBC200WH Blank 2-Gang White Shrink 10 IIIIIIII PBC300GY Blank Round Gray Shrink 10 IIIIIIII PBC300WH Blank Round White Shrink 10 IIIIIIII 1-Gang Device Covers PTC100GY Toggle Gray Shrink 8 IIIIIIII PTC100WH Toggle White Shrink 8 IIIIIIII 2-Gang Device Covers PTC200GY Toggle/Toggle Gray Shrink 4 IIIIIIII PTC521GY Toggle/GFCI Gray Shrink 4 IIIIIIII PTC521WH Toggle/GFCI White Shrink 4 IIIIIIII SEE End of SECTION (PG D48) FOR DETAILED DRAWINGS» D31
32 Non-metallic lighting APPLICATIONS For general outdoor lighting use in wet, damp or dry locations. PRODuCT features Durable high impact PBT construction Includes attached gasket and mounting hardware ComPLIANCES 2014 NEC compliant NEMA 3R rated NO TOOL EASY MOUNT FEATURE LAMPHOLDERS PLTS100GY PLTS100WH Multi-Directional Swivel Joint LAMPHOLDER COVERS x2 PLV330GY, PLV330WH CATALOG # description Color PKG. TyPE Std. PKG. Barcode Lampholders PLTS100GY Swivel Lampholder Gray Shrink 12 IIIIIIII PLTS100WH Swivel Lampholder White Shrink 12 IIIIIIII Lampholder Covers PLV330GY Three 1/2" Holes Gray Shrink 8 IIIIIIII PLV330WH Three 1/2" Holes White Shrink 8 IIIIIIII SEE End of Section (PG D48) for Detailed drawings» D32 BELL WEATHERPROOF
33 Non-metallic Accessories Non-metallic Closure Plugs PCP47550GY PCP47550WH Closure Plug Assortment (Pack of 4) PCP47550GY Two 1/2", Two 3/4" Gray Poly Bag 30 IIIIIIII PCP47550WH Two 1/2", Two 3/4" White Poly Bag 30 IIIIIIII SEE End of SECTION (PG D49) FOR DETAILED DRAWINGS» D33
34 Detailed drawings Die Cast Aluminum BOXES and Extension Rings Single-Gang Boxes (General Dimensions) Extensions: Extensions: , END VIEW ONE OUTLET END VIEW TWO OUTLET Extensions: SERIES Swing arm extension adapters: to Two-gang boxes (General Dimensions) End view for styles with two outlets on one end D34 BELL WEATHERPROOF
35 Detailed drawings TWO-GANG BOXES WITH 7 OUTLETS CAT. NOs , CAT. NOs , TWO-GANG BOXES WITH 5 OUTLETS CAT. NOs , TWO-GANG EXTENSION THREE-GANG BOX 4" ROUND SPLICE BOXES 4" ROUND EXTENSION ADAPTERs D35
36 Detailed drawings 4" ROUND COVER metallic round box cover , RaynGuard While-In-Use Metallic Covers 6.52" 3.16" 3.27" " 4.93" 3.16" D36 BELL WEATHERPROOF
37 Detailed drawings " 4.93" 3.28" " 3.16" 4.63" , , " 4.93" 3.27" D37
38 Detailed drawings MX1050 metallic SINGLE-GANG DEVICE COVERS MX " 4.82" 3.02" 3.02" 1.04" 3.02" MX " 1.04" 3.02" 3.02" 3.02" 4.82" 1.04" 4.82" 1.04" 4.82" 1.04" RAYNTITE SINGLE-GANG DEVICE COVERS VERTICAL 4.82" 4.82" 3.02" 3.02" 1.07" 1.07" 3.02" 1.07" RAYNTITE SINGLE-GANG DEVICE COVERS HORIZONTAL gfci style covers duplex style cover CAT. NO , single receptacle style covers Note: device-mount and box-mount cover dimensions are the same 4-1/2" 2-3/4" D38 BELL WEATHERPROOF
39 Detailed drawings CAT. NOs series, , CAT. NO series CAT. NO CAT. NO /4" 4-1/2" CAT. NO CAT. NO /4" 4-1/2" metallic two-gang DEVICE COVERS MX2050 MX " 4.82" 4.82" 4.82" 4.82" 4.82" 4.79" 4.79" 1.00" 1.00" 4.79" 1.00" 4.79" 4.79".98".98" 4.79".98" D39
40 Detailed drawings metallic two-gang DEVICE COVERS RAYNTITE , TWO-GANG DEVICE COVERS SERIES, , , Note: Dimensions are the same for device mount and box mount styles shown SERIES, /16" 4-1/2" /16" /16" 4-1/2" 4-1/2" /16" 4-1/2" D40 BELL WEATHERPROOF
41 Detailed drawings three-gang DEVICE COVERS MX " 4.82" 4.82" 6.60" 6.60" 6.60" 1.00" 1.00" 1.00" MK1250 metallic Complete COVER KITs 3.02" 3.02" 4.82" 4.82" 3.04" 3.04" D41
42 Detailed drawings metallic Blank Covers single-gang blank covers two-gang Three-Gang metallic Toggle Switch Covers single-gang 5121 SERIES 5141 SERIES CAT. NOs , two-gang CAT. NO , 5125 SERIES TWO-GANg 5167 series TWO-GANG 5166 series three-gang CAtalog No toggle switch CAtalog Nos D42 BELL WEATHERPROOF
43 Detailed drawings RECTANGULAR CLUSTER COVERS 5186 SERIES, 5189 SERIES metallic Lampholder covers ROUND CLUSTER COVERS 5193 SERIES, 5197 SERIES metallic Lampholders LAMPHOLDERS 5606 SERIES, CATalog no CATalog no LHS " 3.30" 3.30" 3.30" 5613 SERIES 3.62" 3.62" 2.65" 2.60" LTS " 2.65" 2.60" 2.60" D43
44 Detailed drawings metallic Bullet Light and POrtable Lampholders Bullet lampholder assembly SPLED2Z 6.62" 6.62" 3.15" 3.15" 6.62" 3.15" 3.31" SL101B 3.31" 2.25" 3.31" 2.25" portable lampholder assembly D44 BELL WEATHERPROOF
45 Detailed drawings metallic Lampholder combinations and Garden Light 5620 SERIES 5621 SERIES 5624 SERIES 5625 SERIES , replacement globe: , catalog # dia. height " 7" " 8-3/4" catalog # dia. height /4" 5" /4" 6-3/4" D45
46 Detailed drawings PE " 6" MIN accessories 1.13" 2.06".65" 1.65" 6" MIN.65" ROUND CLOSURE PLATES Catalog No Catalog No Catalog No box mounting lug Catalog No Gasket: CAtalog no Gasket: CAtalog no Gaskets: CAtalog no D46 BELL WEATHERPROOF
47 Detailed drawings NON-metallic Boxes PSB37550 PRB " 4.27" 1.50" 2.80" 2.00" PDB77550G 4.63" 4.27" 1.50" 4.63" 2.00" NON-metallic COVERS PBC100 PBC " 4.85" 4.62" 2.87".30" 2.87".30" 4.85".31" 2.87".30" D47
48 Detailed drawings NON-metallic COVERS PBC300 PTC " 4.26".31".26".31" 4.26".31" PTC " PLV " 84" 4.84" 4.84" 4.84" 4.84" 1.20" 1.20" 1.20" " 1.25" 1.25" PTC " 82" 4.82" 1.20" 4.82" 1.20" D48 BELL WEATHERPROOF
49 Detailed drawings NON-metallic Lighting PLTS " 2.97" 2.60" 2.97" 2.97" NON-metallic Accessories PCP ".85" 1/2" NPT 3/4" NPS.29".34" D49
Weatherproof Products
Cooper Crouse-Hinds Commercial Products Weatherproof Products Complete line of Weatherproof Products includes: Outlet Boxes & Covers Conduit Outlet Bodies, Covers & Gaskets Vaporproof Lighting Cast Enclosures
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
NEC 2014 Code Changes
NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables
RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:
RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,
B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related
Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index
Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
26 0533 Raceway and Boxes for Electrical Systems Page 1 of 7
Last Update: November, 2015 A. Conduits: Consultant s Handbook Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which
Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE
LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE Applies to Models: 75W, 150W, 300W, 600W, 900W, 1200W ATTENTION: Please read this guide carefully to ensure safe and efficient
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
Batibox TM flush-mounting boxes for dry partitions
flush-mounting boxes for dry partitions 800 51 800 42 800 53 800 54 800 42 + 800 71 800 77 Cat.Nos 1-gang boxes For 1 module 20 800 40 Drilling diameter 32 mm Depth 40 mm For 1 gang or 2 modules For wiring
Lighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
FITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features
and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Ridge Top Construction. Furnished with Internal Ground Screw. Fittings FITTINGS: CAST DEVICE BOXES
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
Generator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
UL/CSA LISTED. THE SIDING SOLUTION!TM PAINTABLE SIDING MOUNTING BOXES, KITS & BLOCKS FOR ALL SIDING TYPES AND FLAT SURFACES Arlington
UL/CSA LISTED THE SIDING SOLUTION!TM PAINTABLE SIDING MOUNTING BOXES, KITS & BLOCKS FOR ALL SIDING TYPES AND FLAT SURFACES Siding Solutions from! Flat /4", 5/6" /" 5/8" Dutch Lap New and Retro Siding Box
Residential Electrical Inspection Checklist
Residential Electrical Inspection Checklist Based on the 2008 National Electrical Code Generally, Minnesota law requires all electrical work to be performed by licensed, bonded and insured electrical contractors
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE
Electrical Conduit & Fittings Catalog HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE Payment Terms: Payment terms are printed on every invoice. Invoices not paid in full by the net due
Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port
Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port Code-Wide Code Change Section 90.5(C). Fine Print Notes are now referred to as "Informational Notes." The purpose, intent,
INSPECTION GUDELINES
GENERAL REQUIREMENTS Building permit and approved set of plans Building permit on the card is the same as on the route "If this is not the first inspection, read inspection records and notes on permit
ELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
American National Standard. Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable
ANSI/NEMA FB 1-2012 Revision of ANSI FB 1-2007 American National Standard Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable Secretariat: National Electrical
Residential Electrical Inspection. Checklist
443 Lafayette Road N. St. Paul, Minnesota 55155 www.doli.state.mn.us Residential Electrical Inspection (651) 284-5064 1-800-DIAL-DLI Fax: (651) 284-5743 TTY: (651) 297-4198 Checklist Generally, Minnesota
INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER
INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER 300W 600W 900W 1200W ATTENTION: Please read and understand thoroughly this installation guide to ensure safe and efficient operation of this Power Module 1 Open
Carlon Carflex Liquidtight Flexible Tubing
Carlon Carflex Liquidtight Flexible Tubing Carflex Carflex X-Flex Fittings Cord Grips Pre-Wired Whips www.carlon.com 3 Carflex Liquidtight Flexible Conduit Carflex Liquidtight Flexible Nonmetallic Conduit
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
Invue ECM/EMM EPIC MEDIUM 42-150W
DESCRIPTION The EPIC Collection delivers custom luminaire flexibility with the quality and availability expectations of standard specification grade product. Offered in two housing sizes and hundreds of
USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions
USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com Electrical Industrial and Fleet Solutions Lawson's ELECTRICAL SOLUTIONS Electrical Wire Low voltage (60V) and high voltage (300/600V)
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
GUE, GUB Junction Boxes
E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof
Top Commercial / Residential Electrical Requirements *
Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial
Electrical Code Regulation
Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county
Residential Electrical Inspection. Checklist
Electrical Licensing and Inspection 443 Lafayette Road North St. Paul, Minnesota 55155-4342 www.doli.state.mn.us 651-284-5064 Fax: 651-284-5743 TTY: 651-297-4198 1-800-DIAL-DLI Residential Electrical Inspection
AMERBRITE UNDERWATER WHITE LED POOL LAMP
AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
For Models #6-5001, #6-7501, #10-7501 & #10-12K1
EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE
POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES
INCANDESCENT Compliances: ETL Listed to UL 1598 USA ETL Listed to CSA C22.2 No. 250.0-04 Canada ETL Certified FAA L-810 per FAA AC 150/5343G ICAO Annex 14 Low Intensity Types A (10 cd) & B (32 cd) IMO
Carlon Zip Box Blue Switch and Outlet Boxes
Carlon Zip Box Blue Switch and Outlet Boxes Nonmetallic: Adjustable One-Gang 2-, 3-, 4-Gang Old Work Ceiling Boxes SuperBlue Hard Shell Covers Metallic: Adjustable Ceiling Boxes Innovative Solutions For
INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM
7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL
ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS
Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document
Type 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
ELEC ELE TR CTRIC P IC PRODUCTS RODUCT
ELECTRIC PRODUCTS VCEP-1 ELECTRIC PRODUCTS MODEL SB STANDARD SBF SBT SB FEATURES SBST - Bottom intake, slope discharge SBT - Bottom intake, top discharge SBF - Front intake, top discharge Two piece all
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D
12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work
GE Lighting Evolve LED Wall Pack N Series (EWNA) imagination at work Product Features The next generation of the GE Evolve LED Wall Pack is designed to efficiently illuminate walkways, area, and general
Electrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS
GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas
162 Ultra-Pin Receptacle, Two Hole Mount Redundant ground through frame No rust, die-cast zinc Heavy bosses for extra rigidity Barrel slanted to drain moisture Mounting holes slotted for universal fit
12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending
Patent Pending DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications DuroSite Series LED High Bay Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance
PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS
PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS Merco Contempo Warmer Lamps offer graceful, dramatic styling to match any décor. They are made of exacting tolerance from heavy duty, solid, mandrelspun
PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant
GAI-TRONICS A Hubbell Company PAGE/PARTY Solutions GAI-Tronics Page/Party communication systems provide paging and party-line capabilities... two important plant communication functions in one durable,
DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
DuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
TOKISTAR. Exhibitor TOKISTAR LIGHTING
TOKISTAR Exhibitor TOKISTAR LIGHTING Exhibitor TM T okistar Exhibitor Series is a wet-location festoon lighting system used in amusement parks, shopping centers, street decorations and promenades. Exhibitor
Evolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASB) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
AutoDome Easy II. VEZ Series. Mounting Manual
AutoDome Easy II VEZ Series en Mounting Manual AutoDome Easy II Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 2 Unpacking 7 2.1 Parts List 7 3 Description 9 4 Installing a
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.
www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB The following installation procedures are suggested guidelines for the installation of in-line cable splices. They
ELECTRICAL CONNECTORS
ELECTRICAL CONNECTORS 07-09 00-09 04-09 99-09 116 ELECTRICAL CONNECTORS LIGHT POWER MODULES WORKS WITH STANDARD & LED BULBS! WORKS WITH STANDARD & LED BULBS! CALL US TODAY FOR YOUR MODULITE VEHICLE APPLICATION
Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs
Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs Part #: GAU-LB-400 Page: 1 Made in USA Compliant The GAU-LB-400 LED Low Bay Light offers high light output from a compact
Section M POWER LIFTS
Section M POWER LIFTS December 2009 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 N.A. Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010
GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS
GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS This guideline has been prepared to assist the owner/occupant of a single family dwelling with compliance to the requirements of the National Electrical
ROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
Brackets and Tenons. Product Specifications. PB Series
Product Specifications FINISH Exclusive Colorfast DeltaGuard finish features an E-Coat epoxy primer with an ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation
Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)
Common Electrical Hazards in the Workplace Including Arc Flash Presented by Ken Cohen, PhD, PE & CIH (Ret.) 1 What s New In February 1972, OSHA incorporated the 1971 edition of the National Fire Protection
Power Outlet Panels. Product Guide
Product Guide Construction and Recreational Vehicle (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Power Outlet Panels Construction and RV Power Outlet Panels Product Description...1 Application
STREETLIGHT SYSTEM GROUNDING AND BONDING
Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial
www.aquascapeinc.com
Lighting www.aquascapeinc.com Lighting 49 Aquascape LED Pond and Landscape Lighting, combines style and simplicity. Our newest component fixtures feature a die-cast metal housing finished with a three-part
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Temporary Power Outlet Panels
Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order
18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30
Commercial Products COMMERCIAL PRODUCTS: RIGID AND IMC FITTINGS s Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels,
Evolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASA) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850
Montgomery County Regulation on: ADOPTION OF THE 2008 NATIONAL ELECTRICAL CODE DEPARTMENT OF PERMITTING SERVICES Issued by County Executive Regulation # 15-09 Authority: Code Section 17-2 and 17-3 Supersedes:
Industrial Ringdown/Autodialer Telephone SCR Series
Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada
V A P O R P R O O F b y D e s i g n
VAPORPROOF by Design Function, economy and durability. packed into a single fixture. The Canlet non-metallic vaporproof lighting fixture exceeds all requirements for standard vaporproof lighting. Made
270526-TC Grounding and Bonding for Telecommunications Systems
270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer
HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12
SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications
Box and Conduit Fill Calculations
Box and Conduit Fill Calculations Volume required per conductor Conduit fill - Box sizing Table 314.16(a) : Number of conductors in box 600v, nominal or less CONDUCTORS: 1. Conductors originating outside
ORIGINAL CABLE PLATES
Since 1998, DataComm Electronics has been pioneering innovative solutions for structured wiring. Industry-wide, we are known as the manufacturer who listens to customers, delivering the reliable and affordable
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Scepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.
ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial
Nordson Automatic Spray Gun Support Kits
Nordson Automatic Spray Gun Support Kits Customer Product Manual Issued / For parts and technical support, call the Finishing Customer Support Center at (800) -99. This document is subject to change without
www.hammondmfg.com General Accessories Hardware
Heavy Duty Door Clamping Junction Box Padlock Kit Quick Release Clamp Replacement hardware for use on all 1418 and 1447 Series enclosures. Formed heavy gauge stainless steel clamp with stainless steel