Bulletin 500 Line Open Type Modular Kits and Components. Selection Guide
|
|
|
- Joel Miller
- 9 years ago
- Views:
Transcription
1 Bulletin 00 Line Open Type Modular Kits and Components Selection Guide
2 Bulletin 00, 00F, 0 AC Contactors and Starters Product Overview AC Contactor and Starter Modular Kits and Components sizes 0 for open-type Bulletin 00 top-wired contractors, Bulletin 00F feed-through contactors, and Bulletin 0 fullvoltage starters, are provided as modular kits for faster delivery. Other sizes and enclosed-type devices are also available. Bulletin 00 00F 0 Features Top-wired contactor Feed-through wired contactor Non-reversing starter Continuous Ampere Rating [A] -Phase Power Poles -Phase Power Poles -Phase Power Poles -Phase Power Poles V (/ Hp) 00 00V (-/ 00 Hp) 00 00V (-/ Hp) 00 00V ( 00 Hp) 0V ( Hp) 00 00V ( 00 Hp) Motor Voltage Standards Certifications /EEMAC ICS (Industrial Controls and Systems) UL 0 CSA C., No. ABS /. USCG CFR.0 IEEE UL Listed (File No. E; Guide No. NLDX) (File No. E0; Guide No. NPKR) CSA Certified (LR) CE Marked (Per EN 0) American Bureau of Shipping (ABS) /EEMAC ICS (Industrial Controls and Systems) UL 0 CSA C., No. ABS /. USCG CFR.0 IEEE UL Listed (File No. E; Guide No. NLDX) (File No. E0; Guide No. NPKR) CSA Certified (LR) CE Marked (Per EN 0) American Bureau of Shipping (ABS) 00 V (. 00 Hp) 0V (/ Hp) /EEMAC ICS (Industrial Controls and Systems) UL 0 CSA C., No. ABS /. USCG CFR.0 UL Listed (File No. E; Guide No. NLDX) CSA Certified (File LR ) CE Marked (per EN 0--) American Bureau of Shipping (ABS) Hazardous Location: UL Listed (File No. E0), CSA Certified (File No. LR ) Product Selection Page Page Page Publication 00-SG00A-EN-P
3 Bulletin 00 AC Contactors Cat. No. Explanation Bulletin 00 Open Type Top-Wired Contactor All power connections are at the top of the contactor for wiring convenience Contactor can be field wired for single- or three-phase applications sizes 0 Available as components or a modular kit for faster delivery Product selection can be done via two options: Ordering a complete kit Ordering individual components Top-wired contactor includes a 0V AC coil, () N.O. auxiliary contact, top-wiring kit, and load-side terminal shield, as standard sizes 00, Available as factory assembled Table of Contents Modular Kits... Components... Factory Assembled... Specifications... Full Load Currents of AC Motors... Approximate Dimensions... 0 Standards Compliance /EEMAC ICS UL 0 CSA C. No. ABS /. American Bureau of Shipping UCSG CFR.0 IEEE EN/IEC 0-- CE Marked Certifications CSA Certified (LR) UL Listed (File No. E, Guide No. NLDX) Catalog Number Explanation For flexibility, devices may be ordered in a convenient modular kit or as individual components. A modular kit includes: Base contactor Selectable coil voltage Top-wiring kit Selectable number of poles Load-side terminal shield Selectable options Modular Kit Example Cat. No. 00 B O D 0 a b c d e a A 0 B C D E b Enclosure Type Type O No enclosure Nominal Coil Voltage Voltage Frequency A B C D 0V 0V 0V 0V 0V 00V 0V 0V c 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz F V 0 Hz H 00 0V 0 Hz I V 0 Hz J V 0/0 Hz N 0V 0 Hz VL V DC VG 0V DC d Number of Poles Voltage Three Power Poles and () N.O. Auxiliary Contact Four Power Poles and () N.O. Auxiliary Contact Five Power Poles and () N.O. Auxiliary Contact Options Surge Suppressor for 0 or 0V AC Coil 0 () N.O. Auxiliary Contact () N.C. Auxiliary Contact e Up to () combinations of auxiliary contacts can be selected. Example: indicates () N.O. and () N.C. contacts. 0 Publication 00-SG00A-EN-P
4 Bulletin 00 AC Contactors Product Selection - Modular Kit Προδυχτ Σελεχτιον Προδυχτ Σελεχτιον Product Selection of sizes 0 by Modular Kits 0 Base Contactor Includes a 0V AC coil and () N.O. auxiliary contactor as standard. Coil Voltage The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 00-AO 0 becomes Cat. No. 00-AOD0. [V] AC, 0 Hz J D A N I B C AC, 0 Hz J D H A F B C DC VL VG VG DC voltage code is only available on size 0. When ordering a DC voltage code, add "DC" to the catalog number. Example: 00DC-BOVL0. Options for Modular Kit Continuous Ampere Rating [A] Max. Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating -Phase Motor Voltage -Phase Motor Voltage 00V AC Maximum 0 Hz Note: The base contactor includes a 0V AC coil as standard. For all other voltages, a second coil will be included in the modular kit for field swap out. Options Surge Suppressor for 0 or 0V AC Coil 0 () N.O. Auxiliary Contact () N.C. Auxiliary Contact Up to () combinations of auxiliary contacts can be selected. Example: indicates () N.O. and () N.C. contacts. 0 Hz Power Poles Power Poles Power Poles V 0V 00V 0V 0 V 0 V Cat. No. Cat. No. Cat. No. 00 / AO 0 00-AO 0 00-AO BO 0 00-BO 0 00-BO CO 0 00-CO 0 00-CO DO 0 00-DO 0 00-DO EO 0 00-EO 0 00-EO See page for sizes 00,. Example: Cat. No. 00-COD0--0 includes a size, -pole, contactor with a 0V AC coil, surge suppressor, and () N.O. auxiliary contact. Publication 00-SG00A-EN-P
5 Bulletin 00 AC Contactors Product Selection - Components Product Selection of sizes 0 by Components Base Contactor Coil Auxiliary Contact Contactor Surge Suppressor Power Pole Top Wire Kit Load -Side Terminal Shield Base Contactor Continuous Ampere Rating [A] Cat. No. 0 00F-AOD0 00F-BOD0 00F-COD0 0 00F-DOD0 00F-EOD0 Coils 0 Cat. No. Cat. No. Cat. No. Cat. No. V 0/0 Hz CB0 CC0 CD0 CE0 0V 0 Hz, 0V 0 Hz CB CC CD CE 0V 0 Hz CB CC CD CE 0V 0 Hz, 0V 0 Hz CB CC CD CE V 0 Hz CB0 CC0 CD0 CE0 0V 0 Hz CB CC CD CE V 0 Hz CB CC CD CE 0V 0 Hz, 0V 0 Hz 0V 0 Hz, 00V 0 Hz CB CC CD CE CB CC CD CE V DC -BDC -CDC -DDC 0V -B0DC -C0DC -D0DC DC Note:The base contactor includes a 0V AC coil as standard. For all other voltages, select an alternate component coil for field installation. Surge Suppressor Cat. No. 0V AC -K0 0 0 V AC Varistor -KA0 Power Pole Adders Cat. No. N.O. 0 -P0A N.O. -PA N.O. -PA N.O. -PA Top Wiring Kit Cat. No. 0 -TW0 -TW -TW -TW Terminal Shield Kit Cat. No. 0 -TS0, -TS 0 Auxiliary Contact Contactors Cat. No. N.O. 0 -A N.O. 0 -AA N.C. 0 -B N.C. 0 -BB N.O. and N.C. 0 -AB Publication 00-SG00A-EN-P
6 Bulletin 00 AC Contactors Product Selection - Factory Assembled Product Selection of sizes 00,, as Factory Assembled Continuous Ampere Rating [A] Max. Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating -Phase Motor Voltage -Phase Motor Voltage 00V AC Maximum 0 Hz 0 Hz Power Poles Power Poles Power Poles V 0V 00V 0V 0 V 0 V Cat. No. Cat. No. Cat. No. 00 /.. 00-TOD FOD0 00-FOD GOD HOD JOD KOD0 See page for sizes 0. Coil Voltage The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 00-AO 0 becomes Cat. No. 00-AOD0. [V] AC, 0 Hz J D A N I B C AC, 0 Hz J D H A F B C DC VL VG VG 0 Publication 00-SG00A-EN-P
7 Bulletin 00F AC Feed-Through Contactors Cat. No. Explanation Bulletin 00F Open Type Feed-Through Contactor Feed-through construction Contactor can be field wired for single- or three-phase applications sizes 0 Available as components or a modular kit for faster delivery Product selection can be done via two options: Ordering a complete kit Ordering individual components Feed-through contactor includes a 0V AC coil and () N.O. auxiliary contact, as standard Table of Contents Modular Kits... Components... Factory Assembled... 0 Specifications... Full Load Currents of AC Motors... Approximate Dimensions... 0 Standards Compliance /EEMAC ICS UL 0 CSA C. No. size Available as factory assembled ABS /. American Bureau of Shipping UCSG CFR.0 IEEE EN/IEC 0-- Certifications CE Marked CSA Certified (LR) UL Listed (File No. E, Guide No. NLDX) Catalog Number Explanation For flexibility, devices may be ordered in a convenient modular kit or as individual components. A modular kit includes: Base contactor Selectable coil voltage Selectable options Modular Kit Example Cat. No. 00F B O D 0 a b c d e a A 0 B C D E b Enclosure Type Type O No enclosure Nominal Coil Voltage Voltage Frequency A B C D 0V 0V 0V 0V 0V 00V 0V 0V c 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz F V 0 Hz H 00 0V 0 Hz I V 0 Hz J V 0/0 Hz N 0V 0 Hz VL V DC VG 0V DC 0 d Number of Poles Voltage Three Power Poles and () N.O. Auxiliary Contact e Options Voltage Surge Suppressor for 0 or 0V AC Coil 0 () N.O. Auxiliary Contact () N.C. Auxiliary Contact Up to () combinations of auxiliary contacts can be selected. Example: indicates () N.O. and () N.C. contacts. 0 Publication 00-SG00A-EN-P
8 Bulletin 00F AC Feed-Through Contactors Product Selection - Modular Kit Product Selection of sizes 0 by Modular Kits Base Contactor Includes a 0V AC coil and () N.O. auxiliary contactor as standard. Continuous Ampere Rating [A] -Phase Motor Voltage Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating V 0V 00V 0V -Phase Motor Voltage 0 Hz 0 V 0 V Power Poles 00V AC Maximum 0 Hz Cat. No. 0 00F-AO F-BO F-CO F-DO F-EO See page for size. 0 Coil Voltage The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 00F-AO 0 becomes Cat. No. 00F-AOD0. For other voltages, please consult your local Rockwell Automation sales office or Allen-Bradley distributor. [V] AC, 0 Hz J D A N I B C AC, 0 Hz J D H A F B C DC VL VG VG DC voltage code is only available on size 0. When ordering a DC voltage code, add "C" to the catalog number. Example: 00FC-BOVL0. Note: The base contactor includes a 0V AC coil as standard. For all other voltages, a second coil will be included in the modular kit for field swap out. Options for Modular Kit Options Surge Suppressor for 0 or 0V AC Coil 0 () N.O. Auxiliary Contact () N.C. Auxiliary Contact Up to () combinations of auxiliary contacts can be selected. Example: indicates () N.O. and () N.C. contacts. Example: Cat. No. 00F-COD0--0 includes a size, -pole, contactor with a 0V AC coil, surge suppressor, and () N.O. auxiliary contact. Publication 00-SG00A-EN-P
9 Bulletin 00F AC Feed-Through Contactors Product Selection - Components Product Selection of sizes 0 by Components Base Contactor Coil Auxiliary Contact Contactor Surge Suppressor Base Contactor Continuous Ampere Rating [A] Cat. No. 0 00F-AOD0 00F-BOD0 00F-COD0 0 00F-DOD0 00F-EOD0 Coils 0 Cat. No. Cat. No. Cat. No. Cat. No. V 0/0 Hz CB0 CC0 CD0 CE0 0V 0 Hz, 0V 0 Hz CB CC CD CE 0V 0 Hz CB CC CD CE 0V 0 Hz, 0V 0 Hz CB CC CD CE V 0 Hz CB0 CC0 CD0 CE0 0V 0 Hz CB CC CD CE V 0 Hz CB CC CD CE 0V 0 Hz, 0V 0 Hz 0V 0 Hz, 00V 0 Hz CB CC CD CE CB CC CD CE V DC -BDC -CDC -DDC 0V DC -B0DC -C0DC -D0DC Note:The base contactor includes a 0V AC coil as standard. For all other voltages, select an alternate component coil for field installation. Auxiliary Contact Contactors Cat. No. N.O. 0 -A N.O. 0 -AA N.C. 0 -B N.C. 0 -BB N.O. and N.C. 0 -AB Surge Suppressor Cat. No. 0V AC -K0 0 0 V AC Varistor -KA0 0 Publication 00-SG00A-EN-P
10 Bulletin 00F AC Feed-Through Contactors Product Selection - Factory Assembled Product Selection of size as Factory Assembled Continuous Ampere Rating [A] -Phase Motor Voltage Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating V 0V 00V 0V -Phase Motor Voltage 0 Hz 0 V 0 V Power Poles 00V AC Maximum 0 Hz Cat. No F-FO 0 See page for size 0. Coil Voltage The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 00F-AO 0 becomes Cat. No. 00F-AOD0. [V] AC, 0 Hz J D A N I B C AC, 0 Hz J D H A F B C DC VL VG VG 0 0 Publication 00-SG00A-EN-P
11 Bulletin 0 Full Voltage Starter Cat. No. Explanation Bulletin 0, with Eutectic Alloy Overload Relay Open Type without Enclosure Standards Compliance /EEMAC ICS UL 0 CSA C. No. ABS /. American Bureau of Shipping Bulletin 0 Open Type Full Voltage Starter Feed-through construction Starter can be field wired for single- or three-phase applications sizes 0 Available as components or as a modular kit for faster delivery Product selection can be done via two options: Ordering a complete kit Ordering individual components Starter includes a 0V AC coil and () N.O. auxiliary contact, as standard sizes 00, Available as factory assembled UCSG CFR.0 EN/IEC 0-- CE Marked Catalog Number Explanation For flexibility, devices may be ordered in a convenient modular kit or as individual components. A modular kit includes: Base contactor Selectable overload relay Selectable coil voltage Selectable options Table of Contents Modular Kits... Components... Factory Assembled... Specifications... Full Load Currents of AC Motors... Approximate Dimensions... 0 Certifications CSA Certified (LR) UL Listed (File No. E, Guide No. NLDX) Modular Kit Example Cat. No. a A 0 B C D E O b Enclosure Type Type No enclosure Nominal Coil Voltage Voltage Frequency A B C D 0V 0V 0V 0V 0V 00V 0V 0V c 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz 0 Hz F V 0 Hz H 00 0V 0 Hz I V 0 Hz J V 0/0 Hz N 0V 0 Hz VL V DC VG 0V DC 0 B O D AE blank a b c d e d Eutectic Overload Relay Eutectic Alloy E Plus Solid-State Overload Relay Full Load Current Adjustment Range [A] -Phase AC 0, 0..0 AE 0,.0.0 AF 0,. AG 0,,. AJ,, AL 0 AM 0 0 -Phase SE 0,.0.0 SF 0,. SG 0,,. SJ,, SL 0 A 0 e Options () N.O. Auxiliary Contact for use on Eutectic Overload Relay () N.C. Auxiliary Contact for use on Eutectic Overload Relay Surge Suppressor for 0 or 0V AC Coil () N.O. Auxiliary Contact for use on Contactor () N.C. Auxiliary Contact for use on Contactor Up to () combinations of auxiliary contacts can be selected. Example: indicates () N.O. and () N.C. contacts. Heater Elements Starters with eutectic alloy overload relays require heater elements. See the Industrial Controls catalog for heater element selection tables. 0 Publication 00-SG00A-EN-P
12 Bulletin 0 Full Voltage Starter Product Selection - Modular Kits Product Selection of sizes 0 by Modular Kits 0 Base Contactor Includes a 0V AC coil and () N.O. auxiliary contactor as standard. Heater Elements Starters with eutectic alloy overload relay require heater elements. See the Industtrial Controls catalog for heater element selection tables. Coil Voltage The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 0-BA - becomes Cat. No. 0-BAD-. [V] Options for Modular Kit Overload Relay Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete, select an overload relay code from the table below to complete the cat. no. Example: Cat. No. 0-BOD- becomes Cat. No. 0-BOD-AE. Full Load Current (-Phase) (-Phase) Range [A] AC AC.0.0 AE AE SE SE. AF AF SF SF. AG AG AG SG SG SG AJ AJ AJ SJ SJ SJ 0 AL SL 0 0 AM Up to () combinations of auxiliary contacts can be selected. Example: indicates () N.O. and () N.C. contacts. Example: Cat. No. 0-BOD-AF--0 includes a size, -pole, contactor with a 0V AC coil, surge suppressor, and () auxiliary contacts, () N.O. and () N.C.. Options () N.O. Auxiliary Contact for use on Eutectic Overload Relay A Continuous Ampere Rating [A] -Phase Motor Voltage () N.C. Auxiliary Contact for use on Eutectic Overload Relay Surge Suppressor for 0 or 0V AC Coil 0 () N.O. Auxiliary Contact for use on Contactor () N.C. Auxiliary Contact for use on Contactor Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating V 0V 00V 0V -Phase Motor Voltage Publication 00-SG00A-EN-P Power Poles 00V AC Maximum 0 Hz 0 Hz 0 V 0 V Cat. No. 00 / AO BO CO DO EO See page for sizes 00,. AC, 0 Hz J D A N I B C AC, 0 Hz J D H A F B C DC VL VG VG DC voltage code is only available for sizes 0. When ordering a DC voltage code, add "DC" to the catalog number. Example: 0DC-BOVL.
13 Bulletin 0 Full Voltage Starter Product Selection - Components Product Selection of sizes 0 by Components Base Contactor Eutectic Overload Relay Solid-State Overload Relay Coil Auxiliary Contact Contactor Surge Suppressor Auxiliary Contact Eutectic Overload Relay Base Contactor Continuous Ampere Rating [A] Cat. No. 0 00F-AOD0 00F-BOD0 00F-COD0 0 00F-DOD0 00F-EOD0 Eutectic Overload Relays Cat. No. 0, -EUTB -EUTC -EUTD -EUTE Solid-State E Plus Overload Relays Current Range [A] Cat. No. -Phase 0, EEBC 0,.0.0 -EECC 0,. -EEDC 0. -EEEC 0 -EEFC -EEFD 0 -EEGD 0 0 -EEHE -Phase 0,.0.0 S-EEPC 0,. S-EERC 0. S-EESC 0 S-EETC 0 S-EEUD Coils 0 Cat. No. Cat. No. Cat. No. Cat. No. V 0/0 Hz CB0 CC0 CD0 CE0 0V 0 Hz, 0V 0 Hz CB CC CD CE 0V 0 Hz CB CC CD CE 0V 0 Hz, 0V 0 Hz CB CC CD CE V 0 Hz CB0 CC0 CD0 CE0 0V 0 Hz CB CC CD CE V 0 Hz CB CC CD CE 0V 0 Hz, 0V 0 Hz 0V 0 Hz, 00V 0 Hz CB CC CD CE CB CC CD CE V DC -BDC -CDC -DDC 0V DC -B0DC -C0DC -D0DC Auxiliary Contact Contactors Surge Suppressor Cat. No. 0V AC -K0 0 0 V AC Varistor -KA0 Cat. No. N.O. 0 -A N.O. 0 -AA N.C. 0 -B N.C. 0 -BB N.O. and N.C. 0 -AB 0 Overload Accessory Auxiliary Contact (For eutectic alloy overload relays only ) Cat. No. N.O. -A0 0 N.C. -B0 N.O. -A N.C. -B Auxiliary contact for solid-state overload relays is included in the product. Auxiliary contact mounted on right-hand side of overload relay provides N.O. contact function. Auxiliary contact mounted on left-hand side of overload relay provides N.C. contact function. To be mounted on right-hand side of overload to provide additional AC contact function. Publication 00-SG00A-EN-P
14 Bulletin 0 Full Voltage Starter Product Selection - Factory Assembled Product Selection of sizes 00, as Factory Assembled Heater Elements Starters with eutectic alloy overload relay require heater elements. See the Industtrial Controls catalog for heater element selection tables. Continuous Ampere Rating [A] -Phase Motor Voltage Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating V 0V 00V 0V -Phase Motor Voltage Power Poles 00V AC Maximum 0 Hz 0 Hz 0 V 0 V Cat. No. 00 /.. 0-TO FO GO HO JO KO - See page for sizes 0. Coil Voltage The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 0-FO - becomes Cat. No. 0-FOD-. [V] AC, 0 Hz J D A N I B C AC, 0 Hz J D H A F B C DC VL VG VG 0 E Plus Solid-State Overload Relay (Selectable Class 0, 0, or 0) (Automatic/Manual Reset) 00 Full Load Current Adjustment Range (A) Overload Relay Class 0,, 0, 0 AA AC AE AF PW 0 00 AN YD PW 0 00 AR YD 0 AT AU 00 0 AV These solid-state overload relays have an interposing relay with a 0V AC coil. Publication 00-SG00A-EN-P
15 Bulletin 00 Line AC Contactors and Starters Specifications Electrical Ratings 00 0 P Load Voltage [V] Continuous Current Rating [A] Service Limit Current Rating [A] Maximum Hp Rating (Non-plugging and non-jogging duty) Maximum Hp Rating (Plugging and jogging duty) Transformer Primary Switching kva Rating (Inrush Current 0 times Continuous Current) Transformer Primary Switching kva Rating (Inrush Current = 0 to 0 times Continuous Current) Capacitor Switching kvar Maximum Circuit Closing Inrush Current [A] Peak Including Offset Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø / -/ -/ -/ -/ -/ -/ -/ / / / -/ -/ Service-Limit Current Ratings The service-limit current ratings shown represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or the trip current of other motor protective devices used shall not exceed the service-limit current rating of the controller. Plugging or Jogging Service The listed horsepower ratings are recommended for those applications requiring repeated interruption of stalled motor current encountered in rapid motor reversal in excess of five openings or closings per minute and shall not be more than ten in a ten minute period. If maximum available current (at capacitor terminals) is greater than 000 A, please contact your local Rockwell Automation sales office, Allen-Bradley distributor, or ICS- Standard. -/ -/ -/ -/ -/ -/ Publication 00-SG00A-EN-P
16 0 Bulletin 00 Line AC Contactors and Starters Specifications, Continued Mechanical Ratings Short Circuit Rating Mechanical Life (Millions of Operations) Maximum Number of Auxiliary Contacts Pick-up (Average) Operating Time [ms] Drop-out (Average) Construction Power Contacts Contact Material Auxiliary Contacts Type of Power Terminal Wire for Power Terminals Required Torque on Power Terminal Wire Clamps and Pressure Connectors or Lugs 0 # 0 AWG 0 lb in Saddle or wire clamps # AWG 0 lb in # AWG lb in # /0 AWG 0 lb in Pressure terminals # /0 AWG lb in Silver alloy Silver # AWG 00 MCM lb in Lugs sold separately. See [S-]. Direct bus connections only. 00 Pressure terminals # 0 AWG lb in Requirements for Sizing of Wire All wire rated F ( C) or higher must be sized per the local Electrical for F ( C) wire. Environmental Operating Temperature Range Altitude Corrosion-Resistance Operating Position 0 Starters with eutectic alloy Overload relay + F ( + C) Vertical Starters with SMP All metal parts are treated for feet before derating Overload relay corrosion-resistance + F Horizontal 00 ( + C) (provided condensation is prevented) Vertical Horizontal Combination contactors and starters with disconnect switch: Bulletin 0, 0,, E, F, G, and X Combination Contactors and Starters with Disconnect Switch: Bulletin 0, 0,, E, F, G, and X Available Short Circuit Amperes RMS Fuse Type Symmetrical [A] Maximum Voltage [V] 0 H, K 000 H, K J, R L 000 L 000 Publication 00-SG00A-EN-P
17 Bulletin 00 Line AC Contactors and Starters Specifications, Continued AC Coil Data Operating Volt Amperes Burden [VA] Inrush 0 Hz Coils Sealed Heat Dissipation [W] ( poles) 0. ( poles). ( poles) 0 0 ( poles) 0 0 ( poles). ( poles) 0. (Series L) (Interposing relay).. Economized DC Coil (Interposing relay).0. Economized DC Coil (Interposing relay).0. Economized DC Coil (Interposing relay).0 Coil Operating Limits 0% This rating is for the size contactor coil only. All starters are shipped with an interposing relay as standard. starters are shipped with a 0 VA control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. starters are shipped with a 0 VA control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. starters are shipped with a 0 VA control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. Auxiliary Contacts ( A00 and P00) Bulletin, AC Rating Designation A00 Maximum Voltage 0 or 0 Hz Maximum AC Contact Rating Per Pole [A] Continuous [VA] Carrying Current Make Break [A] Make Break Maximum DC Contact Rating Per Pole for, Auxiliary Contacts (Maximum Continuous Carrying Current is A) DC Rating Designation V DC 0V DC 00V DC P00 0. A. A (Requires Contacts in Series) 0. A (Requires Contacts in Series) 0 Publication 00-SG00A-EN-P
18 Bulletin 00 Line AC Contactors and Starters Specifications, Continued Load-Life Curves Bulletin 00 Line contactors and starters are designed to provide superior performance in a variety of applications. These load-life curves are based on Rockwell Automation tests according to the requirements defined in IEC -. Actual contact life may vary based on the application, duty cycle, and environmental conditions from that indicated by the curves. To find the contactor s estimated electrical life, follow these guidelines: Choose the appropriate graph that most closely approximates the utilization category of the application. Locate the intersection of the life-load curve of the appropriate contactor with the application s operational current (I e ) found on the horizontal axis. Read the estimated contact life in millions of operations along the vertical axis. Contact Life for Mixed Utilization Categories AC and AC In many applications, the utilization category cannot be defined as either purely AC or AC. In those applications, the electrical life of the contactor can be estimated from the following equation: L = mixed L AC L AC AC + P ( ) L AC Where: L mixed = Approximate contact life for a mixed AC/AC utilization category application L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) P AC = Percentage of AC operations Utilization Categories CategoryTypical Duty ACStarting of squirrel cage motors and switching off only after the motor is up to speed. ACStarting of squirrel cage motors with inching and plugging duty. Bulletin 00 Load/ Life Curves AC and AC 0M M M SIZE AC SIZE 0M M M AC M M M M OPERATING CYCLES M 00K 00K 00K 00K 00K 0K OPERATING CYCLES M 00K 00K 00K 00K 00K 0K 0K 0K 0 0K 0K 0K 0K 0K OPERATIONAL CURRENT le (APMERES) 0K OPERATIONAL CURRENT le (APMERES) Publication 00-SG00A-EN-P
19 Bulletin 00 Line AC Contactors and Starters Specifications, Continued Full Load Currents of -Phase, 0 Hertz AC Induction Motors The full load currents listed below are average values for horsepower rated motors of several manufacturers at the more common rated voltages and speeds. These average values, along with the similar values listed in the U. S. National Electrical (NEC), should be used only as a guide for selecting suitable components for the Motor Branch Circuit. The rated full load current, shown on the motor nameplate, may vary considerably from the listed value depending on the specific motor design. ATTENTION: The motor nameplate full load current should always be used in determining the rating of the devices used for Motor Running Overcurrent Protection. Full Load Current [A] Full Load Current [A] HP RPM 0V 0V 0V 00V 00V 000V HP RPM 0V 0V 0V 00V 00V 000V / / / / -/ -/ Synchronous speed nameplate is usually less due to slip Publication 00-SG00A-EN-P
20 Bulletin 00 Line AC Contactors and Starters Approximate Dimensions Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 00 and 00F Contactors 0 0 Number of Switching Poles A Width -/ (0.) -/ () -/ () -/ (00) -/ () -/ (0) -/ (.) -/ (0.) -/ (.) () -/ (0.) 0-/ (.) B Height -/ () -/ () 0-/ () -/ (0) For Feed-Through Wiring this dimension is -/ in. ( mm). Dimensions in Inches (Millimeters) C Depth D E -/ () -/ (0) -/ (.) -/ (.) -/ (0) -/ () -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) Approximate Shipping Weight in lbs (kg) (.) -/ (.) -/ (.) (.) -/ (.) -/ (.). (.) (.) () (0). (.). () 0 Publication 00-SG00A-EN-P
21 Bulletin 00 Line AC Contactors and Starters Approximate Dimensions, Continued Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0 Full Voltage Starters with Eutectic Alloy and Solid-State Overload Relay (0) / (.) Dia. Mtg. Holes -/ () -/ () / () (.) 00 with Eutectic Alloy Overload Relay -/ () / (.) Reset Travel A E D B (.) Reset Travel 0 with Eutectic Alloy C.0 (.) 0. () 0. (.). (.) 0. (.) Max. Reset Travel. (0.). (0.). (.) 00 with Solid-State Overload Relay Bul. 0-TO_-A with Bul. A Width B Height Dimensions in Inches (Millimeters) C Relay Reset Depth D E Approx. Shipping Weight in lbs (kg) (0.) 0 -/ (0.) -/ () -/ () -/ (0) -/ (0) -/ (.) -/ (00) -/ () -/ () -/ (0) -/ (0) -/ (.) -/ () -/ () -/ () -/ (0) -/ (0) (.) () -/ () -/ () -/ (0) -/ (0) -/ (0.) -/ () -/ () -/ () -/ (0) -/ (0) (.) -/ () -/ () -/ () -/ (0) -/ (00) 0 () -/ () 0-/ () -/ () -/ () () () -/ () -/ (00) -/ () -/ () 0 (0) 0 () () -/ () () See drawing for dimensions. 0 Publication 00-SG00A-EN-P
22 Bulletin 00 Line AC Contactors and Starters Approximate Dimensions, Continued Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin 0 Full Voltage Starters with Solid-State Overload Relay 0 0 Overload Relay Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus Solid-State E Plus A Width -/ () -/ () -/ (00) -/ (00) -/ () -/ () -/ () -/ () B Height -/ () -/ () -/ () 0-/ () -/ () -/ (0) -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E -/ () -/ () -/ () -/ (0) -/ () -/ () -/ () -/ () -/ (0) -/ () -/ () 0-/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) -/ (0) F Relay Reset Depth -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () Approx. Shipping Weight in lbs (kg). (.).0 (.).0 (.). (.) Publication 00-SG00A-EN-P
23
24 MicroLogix Controller with DeviceNet Interface RSNetWorx software PCMCIA for DeviceNet Control Tower Stack Light DeviceNet ArmorBlock MaXum PanelView Component 00, 00, 00 or with E Plus Solid-State Overload Relay 0 with E or E Plus Solid-State Overload Relay PowerFlex AC Drive D Block I/O Series 0 Photoelectric Sensor Bulletin 0T Limit Switch 00T/H with DeviceNet E Plus Solid-State Overload Relays The Bulletin E Plus electronic overload relays set a new standard for entry level solid-state motor protection. The solid-state design provides accurate, reliable and repeatable protection. Application flexibility is offered through a wide : adjustment range and DIP switch adjustments. Rockwell Automation exclusive insert molded power stabs deliver unmatched robust connections in starter assemblies. Publication 00-SG00A-EN-P September 00 Copyright 00 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
D-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
Catalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B
WHITE PAPER PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS BULLETIN 1497, 1497A, AND 1497B CONTROL CIRCUIT TRANSFORMERS The proper selection of the control circuit transformers is important for suitable
Rotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
Bulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
SMC -3 Specifications
Technical Data SMC -3 Specifications Bulletin Number 150 Topic Page Product Overview 2 Standards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 Wiring Diagrams 6 General Specifications
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content
General Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
CATALOG #250 WWW.DANAHERSPECIALTYPRODUCTS.COM
CATALOG #250 WWW.DANAHERSPECIALTYPRODUCTS.COM TABLE OF CONTENTS Vacuum Control... Low Voltage, Medium Voltage... A NEMA Control - Heavy Duty... TM, 5000... B NEMA Control - General Duty... HP... C Pilot
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
Relays and Timers Specifications Bulletin Number 700
Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
How To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply
GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Medium Voltage Motor Control Assemblies
Medium Voltage Motor Control Assemblies Arc Resistant AMPGARD.1 Product............................................. 2 Application........................................... 2 Features, Benefits and Functions...................................
Guidelines on the Short Circuit Current Rating for Industrial Control Panels
usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Distribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
Buck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Overload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average values,
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................
AP/UP, AP/MIL Series. Magnetic Circuit Protectors
AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic
Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
Low Voltage Fuses For Motor Protection
Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Switching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
1321 Power Conditioning Products
Technical Data 1321 Power Conditioning Products Don t Ignore the Cost of Power Line Disturbance Topic Page Product Overview 2 1321-3R, 1321-3RA, and 1321-3RB Series Line Reactors 3 1321 Reflective Wave
Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000
Systems Products Motor Control Centers Modan 3 Modan 3 UL / CSA ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER MODAN 3 Motor Control Centers Offer: Over 1 years of Motor Control experience
Definite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
Motor Protection Voltage Unbalance and Single-Phasing
Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the
Reducing sizes of control power transformers and power supplies with Eaton s XT IEC motor control
Application Paper AP000001E contents Description Page XT Starter with XTOB Thermal OL XT Manual Motor Controller Control power transformer selection.......... Power supply selection.....................
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings
Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings 8800DB1203 03/2013 Retain for future use. Introduction Short-circuit current s (SCCRs) for variable frequency drives (VFDs) is
ASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL
UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL Definition of Terms / Explanations Overview of Basic Devices Construction Types acc. to UL 508 Self-Protected Combination Motor Controller
Solid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C
41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers
PowerFlex Dynamic Braking Resistor Calculator
Application Technique PowerFlex Dynamic Braking Resistor Calculator Catalog Numbers 20A, 20B, 20F, 20G, 22A, 22B Important User Information Solid-state equipment has operational characteristics differing
12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
How To Build A Germany Power Plant
Medium Voltage Air Insulated Motor Control Featuring AdvanceTM Technology. Medium Voltage Motor Control Center Product Description Contemporary Design Advance TM medium voltage motor control center (MVMCC)
MCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors
I.L. 17405 Revision F Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors RATINGS The maximum horsepower ratings of these motor controllers
Allen-Bradley 1397 400-600HP AC Line Filter Kit
Installation Instructions IN Allen-Bradley 1397 400-600HP AC Line Filter Kit Cat. Nos. 1397-LF600 What This Option Provides What This Kit Contains This option is intended to be applied when the primary
UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training. 2002 Eaton Corporation. All rights reserved.
UL 508A Industrial Control Panels Power Distribution and Control Lunch & Learn Training 2002 Eaton Corporation. All rights reserved. Agenda Who is UL and what role do they play? What is the UL 508A Standard?
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives
User Manual Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives Catalog Number 20A-DG01 Topic Page General Description 2 What Is the DriveGuard Safe Torque Off
Industrial Control Power Transformers
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of