NOTE: If the HF body is stamped HFK, then the cage is replaceable. HF N E S C B 2 H C 5 FT 3/8 x 1/2 ODF S/T Valve Series
|
|
- Morris Cain
- 7 years ago
- Views:
Transcription
1 The HF series is a balanced ported valve designed for refrigeration, air conditioning and heat pump applications. Features Stainless steel replaceable power element eliminates corrosion and prevents valve failure Two body sizes provide capacities from /4 to 0 tons Standard Body HF & HFK The HF is offered several ways: Pre-packaged HFK service kits Include a mix of bodies and power elements with a complete set of cages to serve the most applications with a minimum of parts Individual components Bodies, cages, & power elements may be ordered separately Finished valves Assembled valves ready for immediate installation Bi-Flow capability up to 5- tons R- allows one valve to control the superheat in both cooling and heating modes Extended Body HF Capacity range from 8 to 0 tons (R-) Finished valve only NOTE: If the HF body is stamped HFK, then the cage is replaceable. Options ODF or SAE connections Straight-through or angle flow configurations Removable inlet strainer (ODF only) Internal or external equalizer Specifications Maximum working pressure: 450 psig UR/CUR file number: SA53 Nomenclature example: SC HC 5 FT 3/8 x ODF S/T HF N E S C B H C 5 FT 3/8 x ODF S/T Valve Series Equalizer Charge Code Connection Type Configuration Balanced Port Design Superheat Adjustment N = Non- Adjustable Omit for Adjustable E=External (Omit for Internal) Connection Type S = Solder (Omit for SAE Flare) Removable Inlet Strainer (optional) C = Inlet Strainer (ODF only) Bleed Hole (optional) (Omit for no bleed hole) Capacity Nominal Rating in Tons (See nominal capacity table below) + = R-, R-34a, R-450A and R-53A are interchangeable refrigerant charges * =, R-50, R-404A, R-448A and R-449A are interchangeable refrigerant charges = R- and are interchangeable refrigerant charges Refrigerant Code +F = R- H = R- +M = R-34a N = * P = * R = R-50 * S = R-404A *B = R-448A /R-449A +D=R-450A /R-53A C = medium temp CA = heat pump W(MOP) = press. limiting Z = low temp AA = wide range Capillary Tube Length 5 FT (std) Inlet x Outlet Connection Sizes /4 x 3/8 3/8 x SAE = flare ODF = solder ANG = 90 angle S/T = straight-thru HF Series-Nominal* Capacity Tables in Tons (kw) Standard Body HF R- R-34a R-450A/ R-53A R-/ R-50/ R-404A/ **R-448A/ R-449A /8 (0.4) /4 (0.9) /5 (0.7) /4 (0.9) /8 (0.4) /4 (0.9) /4 (0.9) (.8) /4 (0.9) (.8) /4 (0.9) (.8) (.8) 3/4 (.7) (.8) (3.5) (.8) (3.5) (3.5) (3.5) 3/4 (.7) ½ (5.3) (3.5) - (5.3) ¼ (4.4) ½ (5.3) (3.5) (7.0) ¼ (4.4) (7.0) ½ (5.3) ¾ (6.) ½ (5.3) ½ (8.8) ½ (5.3) - (9.0) (7.0) ½ (8.8) (7.0) 3 (.0) (7.0) 3- (.0) 3½ (.0) 4 (4.0) 3½ (.0) 5½ (0.0) 3½ (.0) 6 (.0) Extended Body HF R- R-34a R-450A/ R-53A R-/ R-50/ R-404A/ **R-448A/ R-449A 5 (7.0) 6 (.) 4½ (6.0) 8 (8.0) 5 (7.0) 8½ (30.0) 6 (.0) 7½ (7.0) 6 (.0) 0 (35.0) 7 (7.0) 0½ (37.0) 9 (3.0) (39.0) 9 (3.0) 5 (53.0) 0 (35.0) 6 (56.0) (4.0) 4 (50.0) ½ (40.0) 0 (70.0) 3 (46.0) 0 (70.0) All capacities shown are at 00 F condensing, 40 F evaporator temperature. *See Extended Capacity Tables for ratings at a wide range of conditions per ARI standard 750. **Use SZ charge for all R-448A/R-449A applications. Recommend oversizing the valve capacity by 50% for low temperature applications. 004FC-8 R6 (0/6) TXV 8
2 Dimensional Data Standard Body HF ¼ thru 5½ tons R- HF SAE Connection Size Inlet Outlet A B C /4 SAE SAE 3. 3/8 SAE SAE SAE ODF ODF w/optional strainer at inlet Extended Body HF 8, 0, 5 & 0 ton R HF ODF Connection Size A± Inlet Outlet.00 B±.00 C MIN D MIN /4 ODF 3/8 ODF /8 ODF ODF /8 ODF ODF E F ODF 004FC-8 R6 (0/6) TXV 9
3 Ordering Information Use the following tables to order individual components. HFK Body Selection Table PCN Description Type Connections (Inlet x Outlet) KT-098- HFK /4 x SAE Ang Inlet KT-098- HFK 3/8 x SAE Ang Inlet KT HFKE /4 x SAE Ang Inlet KT HFKE 3/8 x SAE Ang Inlet KT HFKSC 3/8 x ODF Ang Inlet w/ Strainer KT HFKESC 3/8 x ODF Ang Inlet w/ Strainer KT HFKS 3/8 x ODF S/T KT HFKS 3/8 x 5/8 ODF S/T KT HFKS x 5/8 ODF S/T KT HFKS x 7/8 ODF S/T KT-098- HFKES 3/8 x ODF S/T KT-098- HFKES 3/8 x 5/8 ODF S/T KT HFKES x 5/8 ODF S/T KT HFKES x 7/8 ODF S/T HF & HFK Power Element Table PCN Description System Refrigerant(s) Application X6300-FW5- R-34a/R- Low Temp MOP X6300-FW35- R-34a/R- Low Temp MOP X6300-FW55- R-34a/R- Low Temp MOP X6300-FZ- R-34a/R- Low Temp X6300-FC- R-34a/R- Medium Temp X6300-MC- R-34a Medium Temp X6300-HZ- R-/ Low Temp X6300-HCA- R-/ Heat Pump X6300-HW00- R-/ AC MOP X6300-HC- R-/ A/C Med. Temp X6300-SW45- R-404/ / R-50 Low Temp MOP X6300-SZ- R-404/ / R-50 Low Temp X6300-SC- R-404/ / R-50 Medium Temp HFK Cage Nominal* Capacity Table PCN Description Cage Code R- R- R-34a R-404 R KT ⅛ ¼ ¼ ⅛ ⅛ ⅛ ¼ KT-099- ¼ ½ ½ ¼ ¼ ¼ ½ KT-099- ½ ¾ ½ ½ ½ KT ½ ½ KT ¼ ½ ¼ ¼ ¼ KT ½ ½ ¾ ½ ½ ½ ½ KT ½ KT ½ 5½ 4 3½ 3½ 3½ 5½ Cage Kit includes Cage, Insertion Tool and ID Clips. *All capacities shown are at 00 F condensing, 40 F evaporator temperature. See Extended Capacity Tables for ratings at a wide range of conditions per ARI standard 750. Replacement Parts SAE Inlet PCN Part Number Description X-76-3/8 Inlet Filter Screen Seal Cap X-76-7 /4 Inlet Filter Screen Replacement Parts- HFSC & SC Only PCN Kit Number Description KT-064 Includes seal cap, gasket o-ring, screen, spring Cage Kit (PCN ) Item Qty Size 0 Cage (/4 ton R-) Size Cage ( ton R-) Size Cage ( ton R-) Size 3 Cage ( ton R-) Size 4 Cage ( ton R-) Size 5 Cage ( ton R-) Size 6 Cage (3 ton R-) Size 7 Cage (5 ton R-) Insertion Tool Oil Bottle Cage ID Tags 6 HFK Accessories PCN Description Cage Box (Empty) Insertion Tool Oil Bottle Cage Gasket Kit ( sets) 004FC-8 R6 (0/6) TXV 0
4 Ordering Information HFK Pre-Packaged Kits The HFK is a pre-packaged kit consisting of a mix of popular bodies and power elements with a complete selection of cages. These kits provide great flexibility allowing valves to be assembled as needed for each application. Three kits are provided as shown below, along with the cage kit which is included in each pre-packaged kit. In addition, custom kits can be assembled by stocking an empty kit case with desired components. SAE/ODF Kit (PCN 06535) Item Qty SAE Kit (PCN ) Item Qty ODF Kit (PCN ) Item Qty Cage Kit (PCN ) Item Qty HFK 3/8 x SAE ANG HFK /4 X ½ Body HFKSC 3/8 X ½ Body Size 0 Cage (/4 ton R-) HFKE 3/8 x SAE ANG HFK 3/8 X ½ Body HFKES 3/8 X ½ Body Size Cage ( ton R-) HFKS 3/8 x ODF S/T HFKE 3/8 X ½ Body HFKESC 3/8 X ½ Body Size Cage ( ton R-) HFKES 3/8 x ODF S/T FC Power Element FC Power Element Size 3 Cage ( ton R-) Cage Kit (PCN ) HC Power Element HC Power Element Size 4 Cage ( ton R-) Insertion Tool (PCN ) HZ Power Element HZ Power Element Size 5 Cage ( ton R-) Service Box SZ Power Element SZ Power Element Size 6 Cage (3 ton R-) FC Power Element Cage Kit (PCN ) Cage Kit (PCN ) Size 7 Cage (5 ton R-) FZ Power Element Insertion Tool HC Power Element Oil Bottle HZ Power Element Cage ID Tags 6 SC Power Element SW45 Power Element HFK Assembly Procedure (see 6 assembly steps & diagrams below). Remove adjusting stem assembly from body with 5/6 wrench.. Lubricate both o-rings on cage. 3. Insert cage into body with driver and insertion tool and hand tighten. (Do not over-tighten) 4. Replace adjustment stem assembly to body and hand tighten. Use the 5/6 wrench to tighten adjustment stem assembly 60 or one wrench flat. ( inch lbs. - Do not over-tighten) 5. Attach cage identification clip on power element cap tube. 6. Screw power element to top of valve body and hand tighten. Use the wrench to tighten power element 60 or one wrench flat. ( inch lbs. - Do not over-tighten) 004FC-8 R6 (0/6) TXV
5 Ordering Information Use the following tables to order factory assembled valves. HF Series Internally Equalized /4 FC /4 X SAE ANG 5 FT 0098 FC 3/8 X SAE ANG 5 FT FC /4 X SAE ANG 5 FT FC 3/8 X ODF ANG 5 FT R- FC 3/8 X ODF S/T 5 FT HF FC 3/8 X SAE 5 FT HFS FC 3/8 X SAE ANG 5 FT FC 3/8 X ODF S/T 5 FT 0569 FC 3/8 X SAE ANG 5 FT ½ FC 3/8 X SAE ANG 5 FT FC 3/8 X SAE 5 FT MC 3/8 X ODF ANG 5 FT R-34a /4 MC 3/8 X SAE ANG 5 FT R- HF MC 3/8 X ODF S/T 5 FT R-450A HFS MC 3/8 X SAE ANG 5 FT R-53A MC 3/8 X ODF S/T 5 FT HC /4 X SAE ANG 5 FT HC 3/8 X ODF ANG 5 FT /4 HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT 0549 HZ /4 X SAE ANG 5 FT HZ 3/8 X ODF S/T 5 FT HC /4 X SAE ANG 5 FT 0098 HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HZ 3/8 X SAE 5 FT R- HF HC 3/8 X ODF ANG 5 FT HFS HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HZ 3/8 X SAE 5 FT HC 3/8 X ODF ANG 5 FT ½ HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HC 3/8 X SAE 5 FT HZ 3/8 X SAE ANG 5 FT ½ HC 3/8 X SAE 5 FT HC 3/8 X SAE 5 FT HC 3/8 X ODF S/T 5 FT SC /4 X 30 IN /4 SW45 /4 X 30 IN SZ /4 X 30 IN SC /4 X 30 IN SW45 /4 X 30 IN SZ /4 X 30 IN 0665 SC 3/8 X ODF S/T 5 FT R-404A SW45 3/8 X 5 FT 0665 HF SZ 3/8 X 5 FT R-50 HFS SC 3/8 X 5 FT **R-448A **R-449A ½ SW45 3/8 X 5 FT SZ 3/8 X 5 FT SC 3/8 X 5 FT SW45 3/8 X 5 FT SZ 3/8 X 5 FT SC 3/8 X 5 FT ½ SW45 3/8 X 5 FT SZ 3/8 X 5 FT **Use SZ charge for all R-448A/R-449A applications. Recommend oversizing the valve by 50% for low temperature applications. 004FC-8 R6 (0/6) TXV
6 HF Series Internally Equalized (continued) RC /4 X SAE ANG 5 FT RC 3/8 X ODF ANG 5 FT /4 RC 3/8 X SAE 5 FT RZ /4 X 3/8 ODF S/T 5 FT RZ 3/8 X ODF S/T 5 FT 0568 RZ 3/8 X SAE 5 FT RC 3/8 X SAE 5 FT RZ 3/8 X ODF ANG 5 FT HF RZ 3/8 X ODF S/T 5 FT R-50 HFS RZ 3/8 X SAE 5 FT RC 3/8 X SAE 5 FT RC 3/8 X SAE ANG 5 FT RZ 3/8 X ODF ANG 5 FT RZ 3/8 X SAE 5 FT ½ RC 3/8 X SAE 5 FT RZ 3/8 X SAE 5 FT RC 3/8 X SAE 5 FT ½ RC 3/8 X SAE 5 FT FC-8 R6 (0/6) TXV 3
7 Ordering Information (continued) HF Series Externally Equalized (continued) /4 FC 3/8 X SAE ANG 5 FT FC /4 X SAE ANG 5 FT FC 3/8 X ODF ANG 5 FT 0560 FC 3/8 X ODF S/T 5 FT FC 3/8 X SAE ANG 5 FT R- R-34a R- R-450A R-53A R- S S S FC 3/8 X ODF ANG 5 FT FC 3/8 X ODF S/T 5 FT 0565 FC 3/8 X SAE ANG 5 FT ½ FC 3/8 X ODF ANG 5 FT FC 3/8 X SAE ANG 5 FT FC 3/8 X ODF S/T 5 FT FC 3/8 X SAE ANG 5 FT ½ FC 3/8 X SAE ANG 5 FT /4 MC 3/8 X SAE ANG 30 IN MC 3/8 X ODF S/T 5 FT MC 3/8 X SAE ANG 5 FT MC 3/8 X ODF ANG 5 FT /4 MC 3/8 X SAE ANG 30 IN MC 3/8 X ODF S/T 5 FT 0594 MC 3/8 X ODF ANG 5 FT MC 3/8 X ODF S/T 5 FT MC 3/8 X SAE ANG 5 FT ½ MC 3/8 X SAE ANG 5 FT MC 3/8 X ODF S/T 5 FT ¾ MC 3/8 X SAE 5 FT 0585 MC 3/8 X SAE ANG 5 FT MC 3/8 X SAE ANG 5 FT MC 5/8 X 7/8 ODF S/T 5 FT MC 5/8 X 7/8 ODF S/T 5 FT MC 7/8 X /8 ODF S/T 5 FT MC 7/8 X 3/8 ODF S/T 5 FT HC 3/8 X ODF S/T 5 FT /4 HC 3/8 X SAE 5 FT HZ 3/8 X SAE 5 FT HC /4 X SAE ANG 5 FT HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HZ 3/8 X ODF S/T 5 FT HZ 3/8 X SAE 5 FT HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HW 35 3/8 X SAE 5 FT HZ 3/8 X SAE 5 FT HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF S/T 5 FT ½ HC 3/8 X SAE 5 FT HZ 3/8 X ODF S/T 5 FT HZ 3/8 X SAE 5 FT HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HC 3/8 X ODF ANG 5 FT HZ 3/8 X SAE 5 FT HC 3/8 X ODF ANG 5 FT ½ HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF S/T 5 FT HC 3/8 X SAE 5 FT HC X 5/8 ODF ANG 5 FT HCA 3/8 X ODF S/T 5 FT HCA X 5/8 ODF S/T 5 FT HZ 3/8 X ODF S/T 5 FT HZ 3/8 X SAE 5 FT FC-8 R6 (0/6) TXV 4
8 Ordering Information (continued) HF Series Externally Equalized (continued) HC 3/8 X ODF S/T 5 FT 0544 HC 3/8 X SAE 5 FT HC X 5/8 ODF ANG 5 FT HC X 7/8 ODF S/T 5 FT ½ HC 5/8 X 7/8 ODF S/T 5 FT HCA 3/8 X ODF S/T 5 FT HCA X 5/8 ODF ANG 5 FT HZ 3/8 X ODF S/T 5 FT HZ 3/8 X SAE 5 FT R- R-404A R-50 **R-448A **R-449A S S HC X 5/8 ODF S/T 5 FT HC 5/8 X /8 ODF ST 5 FT HCA X 7/8 ODF S/T 5 FT HCA 5/8 X /8 ODF ST 5 FT HC X 5/8 ODF S/T 5 FT HC 5/8 X 7/8 ODF S/T 5 FT HC 7/8 X /8 ODF S/T 5 FT HCA 5/8 X 7/8 ODF S/T 5 FT HCA 58 X /8 ODF S/T 5 FT 0568 HC 5/8 X /8 ODF S/T 5 FT HC 5/8 X 7/8 ODF S/T 5 FT HC 7/8 X /8 ODF S/T 5 FT HCA 5/8 X /8 ODF S/T 5 FT HCA 5/8 X 7/8 ODF S/T 5 FT HCA 7/8 X /8 ODF S/T 5 FT HC 7/8 X /8 ODF S/T 5 FT HCA 7/8 X /8 ODF S/T 5 FT SC /4 X ODF S/T 30IN /4 SW 45 3/8 X ODF S/T 5 FT SW 45 3/8 X SAE ANG 5 FT SZ 3/8 X ODF S/T 5 FT SC 3/8 X ODF ANG 5 FT SW 45 3/8 X ODF S/T 5 FT SW 45 3/8 X SAE ANG 5 FT SZ 3/8 X ODF ANG 5 FT SZ 3/8 X ODF S/T 5 FT SC 3/8 X ODF S/T 5 FT SC 3/8 X ODF ANG 5 FT SW 45 3/8 X ODF ANG 5 FT SW 45 3/8 X SAE ANG 5 FT SW 45 3/8 X ODF S/T 5 FT SZ 3/8 X ODF S/T 5 FT SC 3/8 X ODF ANG 5 FT ¼ SW 45 3/8 X ODF S/T 5 FT SZ 3/8 X ODF S/T 5 FT SC 3/8 X ODF S/T 5 FT ½ SW 45 3/8 X ODF S/T 5 FT SW 45 3/8 X SAE ANG 5 FT SZ 3/8 X ODF S/T 5 FT SC 3/8 X ODF S/T 5 FT SW 45 3/8 X ODF S/T 5 FT SW 45 3/8 X SAE ANG 5 FT SZ 3/8 X ODF S/T 5 FT SC 3/8 X ODF S/T 5 FT ½ SC 5/8 X 7/8 ODF S/T 5 FT 065 SW 45 X 5/8 ODF S/T 5 FT SZ X 5/8 ODF S/T 5 FT SW 45 5/8 X 7/8 ODF S/T 5 FT SC 5/8 X 7/8 ODF S/T 5 FT SZ 5/8 X 7/8 ODF S/T 5 FT SC 5/8 X 7/8 ODF S/T 5 FT SW45 5/8 X 7/8 ODF S/T 5 FT SZ 5/8 X 7/8 ODF S/T 5 FT 0649 SC 5/8 X 7/8 ODF S/T 5 FT SW 45 5/8 X 7/8 ODF S/T 5 FT SZ 5/8 X 7/8 ODF S/T 5 FT 0688 **Use SZ charge for all R-448A/R-449A applications. Recommend oversizing capacity by 50% for low temperature applications. 004FC-8 R6 (0/6) TXV 5
9 Ordering Information (continued) HF Series Externally Equalized (continued) R-50 R-50 (S) (S) /4 ½ 3½ 5 7 RC 3/8 X SAE 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RZ 3/8 X SAE 5 FT RC 3/8 X ODF ANG 5 FT RC 3/8 X ODF S/T 5 FT 0560 RC 3/8 X SAE 5 FT RW 45 3/8 X ODF ANG 5 FT RW 45 3/8 X SAE 5 FT RZ 3/8 X ODF ANG 5 FT RZ 3/8 X ODF S/T 5 FT RZ 3/8 X SAE 5 FT RC 3/8 X ODF ANG 5 FT RC 3/8 X ODF S/T 5 FT RC 3/8 X SAE 5 FT RW 45 3/8 X SAE 5 FT RZ 3/8 X ODF ANG 5 FT RZ 3/8 X ODF S/T 5 FT 0565 RZ 3/8 X SAE 5 FT RC 3/8 X ODF ANG 5 FT RC 3/8 X ODF S/T 5 FT RC 3/8 X SAE 5 FT RW 45 3/8 X ODF ANG 5 FT RW 45 3/8 X ODF S/T 5 FT RW 45 3/8 X SAE 5 FT RZ 3/8 X ODF ANG 5 FT RZ 3/8 X SAE 5 FT RC 3/8 X ODF ANG 5 FT RC 3/8 X ODF S/T 5 FT RC 3/8 X SAE 5 FT RW 45 3/8 X SAE 5 FT RZ 3/8 X ODF S/T 5 FT 0537 RZ 3/8 X ODF ANG 5 FT RZ 3/8 X SAE 5 FT RC 3/8 X ODF ANG 5 FT RC 3/8 X ODF S/T 5 FT RC 3/8 X SAE 5 FT 0544 RW 45 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RZ 3/8 X ODF S/T 5 FT RZ 3/8 X SAE 5 FT RC 3/8 X ODF S/T 5 FT RC 5/8 X 7/8 ODF S/T 5 FT RW 45 5/8 X 7/8 ODF S/T 5 FT RZ X 5/8 ODF ANG 5 FT 0696 RC 5/8 X 7/8 ODF S/T 5 FT RW 45 5/8 X 7/8 ODF S/T 5 FT RC 5/8 X 7/8 ODF S/T 5 FT * For interchangeable refrigerant charges R-34a, R-, R-450A/R-53A, R-404A,, R-50, R-448A/R-449A and R-/, the tons of capacity shown in the table are for the first (primary) refrigerant listed. Consult the Nominal Capacity Table for determining the tons of capacity for the secondary refrigerants listed. Example: A /4 ton R- valve is required. What R-34a ton valve should be selected? Solution: From the Nominal Capacity Table, a ton R-34a valve is equivalent to a /4 ton R- valve. 004FC-8 R6 (0/6) TXV 6
10 Ordering Information (continued) SC Series Externally Equalized (continued) FC 3/8 X ODF ANG 5 FT R- SC FC 3/8 X ODF ANG 5 FT ½ FC 3/8 X ODF ANG 5 FT R-34a /4 MC 3/8 X ODF ANG 5 FT MC 3/8 X ODF ANG 5 FT R- SC MC 3/8 X ODF ANG 5 FT R-450A ½ MC 3/8 X ODF ANG 5 FT R-53A ½ MC 3/8 X ODF ANG 5 FT 0584 /4 HC 3/8 X ODF ANG 5 FT HZ 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT 0579 HZ 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT HZ 3/8 X ODF ANG 5 FT R- R-50 R-404A **R-448A **R-449A SC SC ½ HC 3/8 X ODF ANG 5 FT 0579 HZ 3/8 X ODF ANG 5 FT 0573 HZ 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT ½ HC 3/8 X ODF ANG 5 FT 0574 HZ 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT 0574 HZ 3/8 X ODF ANG 5 FT ½ HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT SC /4 X ODF ANG 30 IN /4 SW45 /4 X ODF ANG 30 IN SZ /4 X ODF ANG 30 IN ½ 3½ /4 ½ ½ 5 SC /4 X ODF ANG 30 IN SW45 /4 X ODF ANG 30 IN SZ /4 X ODF ANG 30 IN SC 3/8 X ODF ANG 5 FT SW45 3/8 X ODF ANG 5 FT SZ 3/8 X ODF ANG 5 FT 0588 SC 3/8 X ODF ANG 5 FT 0589 SW45 3/8 X ODF ANG 5 FT SZ 3/8 X ODF ANG 5 FT 058 SC 3/8 X ODF ANG 5 FT 058 SW45 3/8 X ODF ANG 5 FT 058 SZ 3/8 X ODF ANG 5 FT 0584 SC 3/8 X ODF ANG 5 FT SW45 3/8 X ODF ANG 5 FT SZ 3/8 X ODF ANG 5 FT SC 3/8 X ODF ANG 5 FT 0580 SW45 3/8 X ODF ANG 5 FT 058 SZ 3/8 X ODF ANG 5 FT SC 5/8 X 7/8 ODF ANG 5 FT SW45 5/8 X 7/8 ODF ANG 5 FT SZ 5/8 X 7/8 ODF ANG 5 FT SC 5/8 X 7/8 ODF ANG 5 FT 0649 SW45 5/8 X 7/8 ODF ANG 5 FT SZ 5/8 X 7/8 ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RW 45 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RW 45 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT 0573 RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT *For interchangeable refrigerant charges R-34a, R-, R-450A/R-53A, R-404A//R-50/R-448A/R-449A and R-/ the tons of capacity shown in the table are for the first (primary) refrigerant listed. Consult the Nominal Capacity Table for determining the tons of capacity for the secondary refrigerants listed. Example: A /4 ton R- valve is required. What R-34a ton valve should be selected? Solution: From the Nominal Capacity Table, a ton R-34a valve is equivalent to a /4 ton R- valve. **Use SZ charge for all R-448A/R-449A applications. Recommend oversizing capacity by 50% for low temperature applicatiosn. 004FC-8 R6 (0/6) TXV 7
11 HFSC Series Internally Equalized R-34a /4 MC 3/8 X ODF ANG 5 FT R- HFSC R-450A MC 3/8 X ODF ANG 5 FT R-53A /4 HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT R- HFSC HZ 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT HC 3/8 X ODF ANG 5 FT SC 3/8 X ODF ANG 5 FT /8 SW45 /4 X ODF ANG 30 IN SZ /4 X ODF ANG 30 IN SC 3/8 X ODF ANG 5 FT /4 SW45 /4 X ODF ANG 30 IN SZ /4 X ODF ANG 30 IN R-404A R-50 **R-448A **R-449A HFSC R-50 HFSC ¼ /4 SC 3/8 X ODF ANG 5 FT SW45 /4 X ODF ANG 30 IN SZ /4 X ODF ANG 30 IN SC 3/8 X ODF ANG 5 FT 0585 SW45 3/8 X ODF ANG 5 FT SZ 3/ X ODF ANG 5 FT SC 3/8 X ODF ANG 5 FT 0585 SW45 3/8 X ODF ANG 5 FT SZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT RC 3/8 X ODF ANG 5 FT RZ 3/8 X ODF ANG 5 FT * For interchangeable refrigerant charges R-34a, R-, R-450A/R-53A, R-404A//R-50, R-448A/R-449A and R-/ the tons of capacity shown in the table are for the first (primary) refrigerant listed. Consult the Nominal Capacity Table for determining the tons of capacity for the secondary refrigerants listed. Example: A /4 ton R- valve is required. What R-34a ton valve should be selected? Solution: From the Nominal Capacity Table, a ton R-34a valve is equivalent to a /4 ton R- valve. **Use SZ charge for all R-448A/R-449A applications. Recommend oversizing capacity by 50% for low temperature applications. 004FC-8 R6 (0/6) TXV 8
Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*
EMERSON CLIMATE TECHNOLOGIES-Solenoid Valves & Coils Quick Select Guide Applications Application Feature Valve Nominal Liquid Capacity R-22 (in tons)* Nominal Liquid Capacity R-410A (in tons)* Liquid Line
More informationThermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostatic expansion valves type REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3
More informationD A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction
ALCO s series of Thermo -Expansion Valves are designed for air conditioning, chillers, rooftops, close control, A/C transportation, heat pumps, industrial cooling process and refrigeration applications.
More informationAir Conditioning & Refrigeration Master Catalog. Catalog CIC-2003-1/USA April 2003
Air Conditioning & Refrigeration Master Catalog Catalog CIC-2003-1/USA April 2003 Table of Contents Table of Contents Service Valves Frontseating Valves... page 115 RB01 Series Ball Valves... page 117
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationGeothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls
Geothermal Alliance of Illinois TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls Thermal Expansion Valve Topics Anatomy Operation Terms &
More informationVALVES FOR REFRIGERATING SYSTEMS
VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is
More informationAFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationD A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges
ALCO s TX3 series of Thermo -Expansion Valves are designed for air conditioning, heat pumps and commercial refrigeration applications. The TX3 is ideal for those applications requiring hermetic / compact
More informationPOLICY BULLETIN Tecumseh Compressor Company Compressor Group
to Bulk Milk Coolers and Other System Page 1 of 5 Overall reliability can be enhanced if there exists a complete understanding of the features, system design, installation requirements, processing, charging
More informationDESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
More informationAluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
More informationTXV Selection Guide for Evaporator Coils. Bohn Chandler Dunham-Bush Krack Larkin LRC Russell Witt
TXV Selection Guide for Evaporator s Bohn Chandler Dunham-Bush Krack Larkin LRC Russell Witt TXV Selection for Evap s Model Capacity AA14-42B Russell 4200 10 All-Temp 25 1/2 SAE AFA 1/2 HC HF 1/2 HC AFA
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationIF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationIt will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
More informationSporlan V-Series Ruby Seat Solenoid Valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,
More informationDESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED
More informationRefrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationProduktguide 2004 Kyl- och värmepumpsprodukter
Produktguide 2004 Kyl- och värmepumpsprodukter Subject to change without notice EN3H-0307GE23 R203 - Empty page in PDF - 2 Subject to change without notice EN3H-0307GE23 R203 Contents Overview Designation
More informationEvaporator Coil Installation Instructions
Part # 96654008 July 2010 Evaporator Coil Installation Instructions A-Coil Page 4 Multi-position A-Coil Page 4-7 Slab Coil Page 5 Horizontal A-Coil Top Connection Page 5 Horizontal A-Coil Side Connection
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationTHERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
More informationConstantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
More informationHYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More informationFloat and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationRefrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
More informationAccumulators and Receivers
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog
More informationLocal Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
More informationRecharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
More informationMDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More informationASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationHow To Install An Evaporator Coil
EVAPORATOR COIL INSTALLATION INSTRUCTIONS EVAPORATOR COIL SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... System Requirements... Location Requirements... Drain Requirements... INSTALLATION INSTRUCTIONS...
More informationAlco Controls. Electronic Control. Conventional Control. Page. Electrical Control Valves 5. Electronic Controllers and Sensors 31
Electrical Control Valves Electronic Controllers and Sensors Thermo -Expansion Valves Solenoid Valves Mechanical Pressure Regulators Pressure Controls and Thermostats System Protectors and Moisture Indicators
More informationPVM Piston Pumps Service Manual
PVM Piston Pumps Service Manual PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Table of Contents Service Parts Pump Description... 3 Basic pump Pump Operation Controls Types Part Identification...
More informationPowers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
More informationCOMPRESSED AIR DRYER
COMPRESSED AIR DRYER Model 40211 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight Tools.
More informationWater Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
More informationNORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
More informationTechnical Help Guide
Technical Help Guide Thermal Expansion Valves Electronic Valves & Controls Solenoid Valves System Protectors Regulators Oil Controls Temperature Pressure Controls Basic Rules of Good Practice Troubleshooting
More informationspecializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
More informationMikrotherm. Manual radiator valves. To be precise.
Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.
More informationWater Pump Replacement
1 of 8 2/5/2008 6:36 AM Document ID# 713637 2001 Cadillac Seville Print Water Pump Replacement Tools Required 1. J 38816-A Water Pump Remover & Installer 2. J 38185 Hose Clamp Pliers
More informationNITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
More informationIntroduction; Kit Contents: Page 1
Page 1 of 18 VOLVO AC R134 refit kit instructions for the 700 series FAQ Home Volvo Maintenance FAQ for 7xx/9xx/90 Cars CFC-Free A/C Retrofit Kit for Pre-1993 Volvos Introduction; Kit Contents: Page 1
More informationTHE REPLACEMENT OF R-22
ENGLISH TRANSLATION OF ARTICLE IN FRIO-CALOR AIRE ACONDICIONDAO BY GAS-SERVEI, S.A JUNE 2010 THE REPLACEMENT OF R-22 Courtesy of D. Lluis Giralt Lopez (Chemical Engineering Industrial) Gas Technical Department
More informationV47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
More informationCONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS
CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS BULLETIN 240-10-3 June 2004 Supersedes June 1983 Many centrifugal systems get little maintenance. As a result they operate with the refrigerant highly contaminated
More informationcatalog Single Package Vertical Air Conditioners and Heat Pumps
catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................
More informationApplication Engineering
Application Engineering February 2012 Digital Capacity Control for Copeland Scroll Refrigeration Compressors INDEX Page 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 1 4. Digital
More information2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units
2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units ANSI/AHRI Standard 540 (formerly ARI Standard 540) IMPORTANT SAFETY RECOMMENDATIONS ARI does not
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More informationSTC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
More informationTrash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001
Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001 Specifically designed pumps for heavy duty applications Handles solids with eas and simple to open and clean Standard roll
More informationCooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationPressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
More informationPSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS
PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Merit Series13ACD Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More information2. AIRCONDITIONING AND REFRIGERATION
2. AIRCONDITIONING AND REFRIGERATION 1. INTRODUCTION Air Conditioning and Refrigeration is an important area where in lot of self-employment opportunities are available. Now a day there is hardly a house
More informationTITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V
TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More information2" & 3" Poly Wet Seal Pump Instruction Manual
Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction
More informationSERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2
SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-
More informationSolenoid Valves and Their Importance in Refrigeration Systems. October 2007
Solenoid Valves and Their Importance in Refrigeration Systems October 2007 Overview Introduction Solenoid valves play an important role within refrigeration and air conditioning systems, controlling the
More informationIn-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationAE21-1319 R6 December 2013. Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE21-1319 R6
AE21-1319 R6 December 2013 Digital Capacity Control for Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions...2 Safety Icon Explanation...2
More informationInstallation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
More informationINSTALLATION MANUAL MODEL RP-100
INSTALLATION MANUAL FOR 24 VALVE 5.9L CUMMINS POWERED DODGE TRUCKS 2003 THROUGH 2004.5 MODEL RP-100 READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION 5400 BUSINESS 50 WEST SUITE 8 573 635-0555
More informationCPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
More informationINSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationSplit System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More informationPin & Vee Block Test Machine
Pin & Vee Block Test Machine Picture of the apparatus Used in Standard Test Methods ASTM Standards D 2670, D2626, D3233, D5620 Federal Test Methods FTM-791-3807.1, FTM-791-3812.1 Chrysler Corporation 461-C-84-01,
More informationInstaller s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
More informationAny Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.
I Dave s Statement If the thermostat calls for cooling, and the furnace fan is running properly, and the coil airflow is adequate, and the condenser fan is running properly, and the condenser airflow is
More informationMUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
More information5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationThe prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded
More informationREFRIGERANT REFERENCE GUIDE
REFRIGERANT REFERENCE GUIDE WORLWIDE REFRIGERANT SUPPLIER 2004 FOURTH EDITION 2004 DISCLAIMER This publication is designed to provide accurate and authoritative information. It is not to be construed as
More informationPARTS MANUAL EH12-2 ENGINE. Model. PUB-EP5713 Rev. 7/99
PARTS MANUAL Model EH12-2 ENGINE PUB-EP5713 Rev. 7/99 940 Lively Blvd. Wood Dale, IL 60191 Phone: 630-350-8200 Fax: 630-350-8212 e-mail: sales@robinamerica.com www.robinamerica.com Copyright 1999 Robin
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationNME650 & FME800 INTRODUCTION. Table of Contents
INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain,
More informationRPI Industries, Inc. Parts Department
Model# SCBC96R Bradford 8' Refrigerated Candy Case Parts List Model Name Model # Description Part # Quantity Unit of Measure Bradford 8' Refrigerated Candy Case SCBC96R BALLAST 4 LAMP #GE 432 MV L E000080
More information