1 YOUR SOURCE FOR COMPLETE LIGHT GAUGE STEEL TRUSS SYSTEMS
2 ALL-SPAN, INC. your source for Light Gauge Steel Truss Systems. With today s demanding architectural designs, intricate roof lines, and aggressive schedules, light gauge steel trusses have become a popular product for architects, engineers, builders and developers. All-Span, Inc. can design an engineered, pre-fabricated light gauge steel truss system specifically for your project, incorporating most any design, including gables, hips, valleys, dormers, retail canopy fronts, and much more. Our truss systems are pre-fabricated in a controlled atmosphere in our plant, and shipped to your jobsite, ready for installation. Call us at any time to discuss design possibilities for your next project. Quality products and service based on years of experience in the building component industry.
3 COMPLETE SYSTEMS Unlimited possibilities for commercial roof design. Versatile Pre-fabricated Light Gauge Steel Truss Systems engineered for your specific project. Reliable and cost-effective way for developing large or small scale commercial, institutional or educational construction projects. 1
4 THE ULTRA-SPAN When specifying and purchasing light gauge steel trusses for your next commercial/institutional project, be sure to insist on the most comprehensive system available today. The Ultra-Span System from Aegis Metal Framing offers building designers and contractors real peace of mind. They know all the key elements of a properly functioning structural system are designed and provided. When you select All-Span to design and manufacture your pre-fabricated truss system, you are selecting an experienced truss specialist. Utilizing state-of-the-art light gauge design software, All-Span can efficiently and accurately bid a complete truss system that can include all of the following items: All trusses, including girders, valleys, and specials Truss-to-truss and truss-to-bearing connections Special connections Truss spacing and installation bracing products Permanent bracing Hip, ridge, and valley plates SYSTEM VERSATILE COST EFFECTIVE COMPREHENSIVE NON-COMBUSTIBLE All designed and manufactured to work together as the industry s only true system! Computer designed for precision and factory built for quality and consistency, prefabricated Ultra-Span trusses are the ideal, cost-effective alternative to structural steel, bar joist, fire-treated wood, and site-assembled cold formed metal framing. Contact All-Span for more information on the comprehensive Ultra-Span system! 2
5 ENGINEERED BRACING LAYOUTS These layouts specify location of all permanent lateral bracing required for each specific job. The bracing is then drawn on the layout in easy to read format. Details are provided for attachment of bracing to the trusses. This layout is stamped by a professional engineer registered in the state that the job is located. This product is especially important for jobs that have intricate truss systems. BRACING AND SPECIAL CONNECTION DETAILS Are provided to ensure ease of construction 3
6 ALL-SPAN, INC. PROJECT PROFILE FABRICATOR All-Span, Inc. Bridgeville, DE PROJECT Howard T. Ennis School, Georgetown, DE Although Ultra-Span truss systems are most commonly used in new construction, this project is an outstanding example of how Ultra-Span can be incorporated in a retrofit application. Before: The 40+ year old flat hot tar/gravel roof was beginning to fail. The Howard T. Ennis School was like so many other educational facilities built during the 1960 s. The one-story brick structure was designed with a flat hot tar and gravel roof system. As with most such roofs of this vintage, water leakage and seepage had become a major problem, creating a costly, repetitive maintenance nightmare. In addition, the school district wanted to install new rooftop mechanical units for each classroom that could be hidden from view. Adequate installation and maintenance access for the new rooftop units was easily accomplished by designing and building a large mechanical room into the trusses covering those areas where the units would be located. The obvious solution to these retrofit challenges was a sloped roof with a built-in mechanical space. Although the traditional approach would have been to utilize a structural post and purlin system, the architect wanted to ensure sufficient area for the new air handling units, as well as minimize the number of penetrations in the existing roof membrane. All-Span, Inc. was brought in to help design an optimal re-roof system to provide an attractive, low maintenance sloped roof while minimizing installation time and classroom disruptions. With the assistance of the precise layout, connection, and engineered bracing diagrams (an Ultra-Span system exclusive!) that All-Span provided, the truss installer was able to retrofit the Ennis school in just two weeks! And, by working evenings and weekends, no class time was lost (great news for the parents and educators, bad news for the kids!) The Howard T. Ennis re-roof is a perfect example of how we can help compress construction cycles and reduce total cost through the speed and efficiency of pre-engineered, factory-built components. After: A great-looking new roof. To minimize the number of trusses (and the installation time required), we designed two mono trusses spaced 6 feet on center to cover the 82' x 305' main school building. A short pony wall was built up along the exterior bearing walls and a row of stub posts spaced 6' o.c. were installed along the center of the existing roof. With only one center bearing, the number of roof penetrations was reduced from several hundred for a traditional post and purlin system to only 50 or so for the Ultra-Span solution. 4
7 OTHER ALL-SPAN, INC. PROJECTS FABRICATOR All-Span, Inc. Bridgeville, DE PROJECT Various Tight radius truss design creates a striking roofline for a 7-floor building In addition to its traditional roof shapes, this building employs a tight-radius curve as the building s signature design element. This truss profile employs both a radius top, and built-in gutter detail. Fascia and soffit returns can be applied in our plant on most jobs. 5
8 ULTRA-SPAN 1 TRUSS TO GIRDER CONNECTION DETAIL Also Hip Jack to Front Face of Girder (using the USKW and USGP System) 3.OUSW18 (full BC depth) Attach to girder bottom chord at 12" or 10" oc with #10 screws 4 into 3.5USC bottom chord. 12" or 10" between 3.OUSW18 3 AEGIS HAT CHANNEL Temporary & Permanent Bracing Member 1-1/2" 3-1/8" 45 to AEGIS USTCC TOP CHORD CONNECTOR USGP (full length of truss) Attach to USW18 w/3 - #10 screws (3.5USGP) USW Spacing (In) #10 s Attach USKW to USGP w/4 - #10 screws USKW Connector - Attach to truss between end vertical and bottom chord w/ #10 screws as required for the tie-in truss reaction and bottom chord gauge Allowable Tie-In Truss Reaction (lbs.) Tie-in truss bottom chd. 3.5USGP w/ 3.5" USKW 35USC035 35USC046 35USC Use USTCC to attach top chord of Common Jack to top chord of Hip Girder Attach USTCC to top chord of Hip Girder with (1) #8 or #10 low profile SDS. Bend to the required angle and attach to Common Jack with (2) #8 or #10 low profile SDS. 2 AEGIS USKW CONNECTION DETAIL Hip Jack to Back Face of Girder 5 AEGIS USCJC HIP CORNER JACK CONNECTOR Attach USKW to USGP-X w/4 #10 screws USGP-X (full length of truss). Attach to top flange and lower web w/ #10 screws at 5" oc Attach USCJC to top chord of Corner Girder with (1) #8 or #10 low profile SDS. Bend wings to the required angle and attach to Corner Jack with (2) #8 or #10 low profile SDS. Factory installed and Skewable. 45 to 135 USKW Connector Attach to truss between end vertical and bottom chord w/ #10 screws as required for the tie-in truss reaction and bottom chord gauge Use USCJC to attach top chord of Corner Jack to top chord of Corner Girder #10 s Allowable Tie-In Truss Reaction (lbs.) Tie-in Truss Bottom Chord 3.5USC20 3.5USC18 3.5USC16 5.5USC20 5.5USC18 5.5USC
9 ULTRA-SPAN 6 ULTRA-SPAN TRUSS UPLIFT CONNECTION TO I-BEAM w/ 426HD14 426HD14 426HD14 #10 Self-drilling Screws (4) Hilti X-ZF PAF (or equivalent) #10 Self-drilling Screws (4) Hilti X-ZF PAF (or equivalent) Min. edge distance = 1" Min. edge distance = 1" Maximum Uplift Capacity Web Gauge #10 SDS Uplift (lbs.) ) Web or heel stiffener attached with (8) #10 SDS. 2) Minimum screw spacing = 9/16". 3) Uplift values include 1.33 increase for wind or seismic. No further increase is permitted. For uplifts not resulting from wind or seismic, reduce capacities to 75% of values shown. 4) Minimum steel thickness = 3/8". See Fastener Manufacturer s recommendation for installation. 5) Fill holes in 426HD14. 7 ULTRA-SPAN TRUSS UPLIFT CONNECTION TO I-BEAM w/ 423HD14 423HD14 423HD14 #10 Self-drilling Screws (2) Hilti X-ZF PAF (or equivalent) #10 Self-drilling Screws (2) Hilti X-ZF PAF (or equivalent) Min. edge distance = 1" Min. edge distance = 1" Maximum Uplift Capacity Web Gauge #10 SDS Uplift (lbs.) ) Web or heel stiffener attached with (4) #10 SDS. 2) Minimum screw spacing = 9/16". 3) Uplift values include 1.33 increase for wind or seismic. No further increase is permitted. For uplifts not resulting from wind or seismic, reduce capacities to 75% of values shown. 4) Minimum steel thickness = 3/8". See Fastener Manufacturer s recommendation for installation. 5) Fill holes in 423HD14. 7
10 ULTRA-SPAN USD The new USD (Ultra-Span Deluxe) is a heavier, stronger member that is available to use for projects with any or all of the following design parameters: Low roof pitch Wide truss spacing Low truss heel heights Heavy design loads 8 ULTRA-SPAN DELUXE (USD) TRUSS UPLIFT CONNECTION TO STRUCTURAL STEEL (423HD14 W/ HILTI X-ZF) The wide flange beam shown is a general representation of a structural steel bearing. This detail may be used with other structural steel shapes (tubes, angles, etc.) provided they meet the minimum requirements for size and thickness. 3" 423HD14 X Vertical USWD Height over bearing USWD Web Member attach to USD Top Chord w/#10-16 T/3 sds (see chart). USD Bottom Chord TSB 18 ga. 33 ksi x 6" - Web Cap attach to vertical USWD w/6 #10-16 T/3 sds (see Note #2). (4) - #10-16 T/3 sds Hilti X-ZF PAF (or equiv.). See chart for quantity. Min. edge distance = 1/2" Steel beam (3/8" flange thickness) 1) When permitted by building code and job specification, uplift values may be increased by Uplift must be the direct result of wind or seismic loading. In no case shall the uplift exceed 1200 lbs. 2) TSB attachment to USWD can be reduced to (4) - #10 sds with USWD ) Minimum screw spacing and edge distance = 9/16".4) Minimum bearing width = 3". 5) Refer to Hilti product technical guide for installation requirements and application limits. Equivalent PAFs may be substituted. 6) PAFs to be placed thru or in line with holes in 423HD14. 7) When this connection detail is applied to both plies of a 2-ply truss, the listed capacities double. 8) This detail does not indicate or imply that the depicted bearing material is structurally adequate for the loads shown. Design of the bearing is required. 4" 1-1/2" Maximum Allowable Uplift (Lbs) Height (in) #PAF to #10-16 T/3 SDS thru USWD to USD over bearing bearing X=12" or less /4" 12 < x < 24" X > 24" /16" diameter hole 1/2" 3/4" 3" 9 ULTRA-SPAN DELUXE (USD) TRUSS UPLIFT CONNECTION TO STRUCTURAL STEEL (426HD14 W/ HILTI X-ZF) The wide flange beam shown is a general representation of a structural steel bearing. This detail may be used with other structural steel shapes (tubes, angles, etc.) provided they meet the minimum requirements for size and thickness. X Vertical USWD Height over bearing 426HD or greater USWD Web Member attach to USD Top Chord w/#10-16 T/3 sds (see chart). Attach to bottom chord w/10-#10 sds T/3. USD Bottom Chord TSB 18 ga. 33 ksi x 6" - Web Cap match size to web member. Attach to vertical USWD w/10 #10-16 T/3 sds (see Note #2). (6) - #10-16 T/3 sds Hilti X-ZF PAF (or equiv.). See chart for quantity. Min. edge distance = 1/2" Steel beam (3/8" flange thickness) 1) When permitted by building code and job specification, uplift values mabe increased by Uplift must be the direct result of wind or seismic loading. In no case shall the uplift exceed 2400 lbs. 2) TSB attachment to USWD can be reduced to (6) - #10 sds with USWD ) Minimum screw spacing and edge distance = 9/16". 4) Minimum bearing width = 6". 5) Refer to Hilti product technical guide for installation requirements and application limits. Equivalent PAFs may be substituted. 6) PAFs to be placed thru or in line with holes in 426HD14. 7) When this connection detail is applied to both plies of a 2-ply truss,the listed capacities double. 8) This detail does not indicate or imply that the depicted bearing material is structurally adequate for the loads shown. Design of the bearing is required. 4" 1-1/2" Maximum Allowable Uplift (Lbs) 3/4" Height (in) #PAF to #10-16 T/3 SDS thru USWD to USD over bearing bearing X=12" < x < 24" X > 24" /16" diameter hole 6" 1-1/2" 3/4" 8
11 ULTRA-SPAN 10 ULTRA-SPAN TRUSS UPLIFT CONNECTION TO CONCRETE w/ USP PA18 STRAP 30USW Heel Stiffener USP PA18 STRAP Min. edge distance = 4" #10 Self-drilling Screws Min. edge distance = 4" Min. embedment = 4" Min. embedment = 4" Maximum Uplift Capacity Maximum Uplift Capacity Web Gauge #10 SDS Uplift (lbs.) ) PA18 may be trimmed. Provide minimum 9/16" screw spacing. 2) Refer to USP catalog for proper use of PA. 3) Web or heel stiffener must be attached to chord for uplift load. Refer to chart at right for connection requirements. Use minimum gauge of web or bottom chord for determining required connection. For 073 bottom chord, use 057 connection requirements. Use heel stiffener gauge for stiffener connection. Stiffener Gauge #10 SDS Uplift (lbs.) ) Uplift values include 1.33 increase for wind or seismic. No further increase is permitted. For uplifts not resulting from wind or seismic, reduce capacities to 75% of values shown. 5) Minimum concrete strength shall be 2000 psi. 6) PAHD42 may be used as substitute. Refer to USP catalog for installation requirements. 11 ULTRA-SPAN TRUSS UPLIFT CONNECTION TO LIGHT GAUGE FRAMING w/ USP RT7 1) Uplift values include 1.33 increase for wind or seismic. No further increase is permitted. For uplifts not resulting from wind or seismic, reduce capacities to 75% of values shown. 2) Top track attachment to stud for uplift designed by qualified designer. 3) Minimum screw spacing = 9/16". Maximum Uplift = 565 lbs. USP RT7 #10 Self-drilling Screws 9
12 ULTRA-SPAN 12 ULTRA-SPAN TRUSS UPLIFT CONNECTION TO CONCRETE w/ 426HD14 426HD14 #10 Self-drilling Screws (2) Fasteners (see chart) Min. edge distance = 2" Maximum Uplift Fastener Conc. psi #10 SDS Embed (in) Uplift (lbs) Hilti X-DNI Hilti X-ZF Hilti Kwik-Con II /16" dia Hilti Kwik-Con II /4" dia HD14 #10 Self-drilling Screws (2) Fasteners (see chart) Min. edge distance = 2" 1) Reference manufacturer s catalog for proper installation of fasteners. 2) Web or heel stiffener must be attached to chord with (4) #10 SDS, except for 1/4" Kwik-Con II in 4000 psi concrete, 1.75 embedment use (6) #10 SDS. 3) Uplift values include 1.33 increase for wind or seismic. No further increase is permitted. For uplifts not resulting from wind or seismic, reduce capacities to 75% of values shown. 4) Install fasteners through holes provided in 426HD14. 5) Minimum spacing of fasteners = 3". 6) Minimum spacing of #10 screws = 9/16". 7) Maximum horizontal reaction = 188 lbs. 13 ULTRA-SPAN TRUSS UPLIFT CONNECTION TO LIGHT GAUGE FRAMING w/ 423HD14 423HD14 #10 Self-drilling Screws Min. edge distance = 1" Maximum Uplift Capacity Web Gauge #10 SDS Track Gauge #10 SDS Uplift (lbs) Into Web Into Track gauge gauge (20 gauge) gauge gauge HD14 #10 Self-drilling Screws Min. edge distance = 1" 1) Uplift values include 1.33 increase for wind or seismic. No further increase is permitted. For uplifts not resulting from wind or seismic, reduce capacities to 75% of values shown. 2) Top track design and attachment to stud for uplift by qualified designer. 10
13 ULTRA-SPAN 14 ULTRA-SPAN STABILIZER Precise Truss Spacing & Installation Bracing...All in One! Straight end Yoke end " or 48" Available in 24" and 48" oc sizes! " or 48" 3 Installation instructions Step 1 Attach STABILIZER to first truss at yoke end. Step 2 Snap straight end of STABILIZER onto second truss. Step 3 Install low profile self-drilling screw into yoke end to secure. Step 4 Overlap yoke end of second STABILIZER over the straight end of the first STABILIZER. Step 5 Snap straight end of STABILIZER onto third truss. Step 6 Install low profile self-drilling screw into yoke end to secure. The STABILIZER not only spaces trusses and braces, but can remain in place as roof sheathing is applied. This is just one more way to save money on your project. LESS TIME LESS LABOR = MORE MONEY 11
14 ULTRA-SPAN STRUCTURAL PROPERTIES ALL CHORD AND WEB MEMBERS ALLOWABLE MEMBER DESIGN GROSS SECTION PROPERTIES EFFECTIVE SECTION PROPERTIES YIELD MOMENT TORSIONAL SECTION PROPERTIES DESIGNATION THICKNESS WEIGHT Area Ix rx Iy ry Ix Sx Ae Fy (in.- lbs.) Xo J Cw Ro (inches) (lbs/ft) (in 2 ) (in 4 ) (in) (in 4 ) (in) (in 4 ) (in 3 ) (in 2 ) (ksi) +Ma -Ma (in) (in4) (in6) (in) 35USC USC USC USC USD USD USD USD USD USC USC USC USC USD USD USD USD USD USC
15 USC USC USD USD USD USD USWD USW USW USW USWD USWD USWD USWD USWD USWD USWD USWD how to read member designation 35 USC = 3.5" 55 = 5.5" 72 = 7.25" 30 = 3.0" 362 = 3.62" 60 = 6.0" USC = Ultra Span Chord USD = Ultra Span Deluxe Chord (see page 8) USW = Ultra Span Web USWD = Ultra Span Web Deluxe 035 = 20 gauge 046 = 18 gauge 057 = 16 gauge 073 = 14 gauge 097 = 12 gauge 45 = 45KSI 50 = 50KSI 13
16 ULTRA-SPAN SECTION (formerly 05425) Pre-Engineered, Pre-Fabricated Light Gauge Steel Roof & Floor Trusses PART 1 GENERAL 1.01 SUMMARY A. Section includes pre-engineered, pre-fabricated light gauge cold formed steel framing elements. Work includes: 1. Light Gauge Cold-formed steel open web floor trusses. 2. Light Gauge Cold-formed steel roof trusses. 3. Anchorage, bracing and bridging. B. Related work 1. Drywall attachment 2. Roofing, fascia, soffit 1.02 REFERENCES Reference standards: A. ASTM: 1. ASTM A653/A653M-94 Sheet Steel, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvanealed) by the Hot Dip Process. 2. ASTM A780-93a Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings. B. American Welding Society (AWS) 1. AWS D1.1 Structural Welding Code - Steel. 2. AWS D1.3 Structural Welding Code - Sheet Steel PERFORMANCE REQUIREMENTS A. AISI Specifications : Calculate structural characteristics of coldformed steel truss members according to AISI s Specification for the Design of Cold-Formed Steel Structural Members, 1986 (1990). B. Structural Performance: Design, engineer, fabricate, and erect coldformed steel trusses to withstand specified design loads within limits and under conditions required. 1. Design Loads: As specified. 2. Deflections: Live load deflection meeting the following (unless otherwise specified): a. Floor Trusses:Vertical deflection less than or equal to 1/360 of the span. b. Roof Trusses:Vertical deflection less than or equal to 1/240 of the span. 3. Design framing systems to provide for movement of framing members without damage or overstressing, sheathing failure, connection failure, undue strain on fasteners and anchors, or other detrimental effects when subject to a maximum ambient temperature change (range) of 120 degrees F (67 degrees C) SUBMITTALS A. Submit manufacturer s product data and installation instructions for each type of cold-formed steel framing and accessory required. B. Submit shop drawings showing member, type, location, spacing, size and gauge of members, method of attachment to supporting members and all necessary erection details. Indicate supplemental bracing, strapping, splices, bridging, accessories and details required for proper installation. C. Submit detailed floor truss and roof truss layouts. D. Submit truss drawings, sealed and signed by a qualified registered Professional Engineer, verifying truss ability to meet local code and design requirements. Include: 1. Description of design criteria. 2. Engineering analysis depicting member stresses and truss deflection. 3. Truss member sizes and gauges and connections at truss joints. 4. Truss support reactions. 5. Top chord, Bottom chord and Web bracing requirements QUALITY ASSURANCE A. Fabricator Qualifications: Fabrication shall be performed by a coldformed steel truss fabricator with experience designing and fabricating cold-formed steel truss systems equal in material, design, and extent to the systems required for this Project. 1. Cold-Formed steel truss system installation shall be performed by an experienced installer approved by the steel truss system fabricator. B. Welding Standards: Comply with applicable provisions of AWS D1.1 Structural Welding Code--Steel and AWS D1.3 Structural Welding Code--Sheet Steel. 1. Qualify welding processes and welding operators in accordance with AWS Standard Qualification Procedure DELIVERY, STORAGE AND HANDLING A. Deliver materials in manufacturer s unopened containers or bundles, fully identified by name, brand, type and grade. Exercise care to avoid damage during unloading, storing and erection. B. Store trusses on blocking, pallets, platforms or other supports off the ground and in an upright position sufficiently braced to avoid damage from excessive bending. C. Protect trusses and accessories from corrosion, deformation, damage and deterioration when stored at job site. Keep trusses free of dirt and other foreign matter PROJECT CONDITIONS A. During construction, adequately distribute all loads applied to trusses so as not to exceed the carrying capacity of any one joist, truss or other component. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Manufacturer: Ultra-Span Truss Manufacturer 2.02 COMPONENTS A. System components: Aegis Metal Framing, LLC ULTRA-SPAN and POSI-STRUT light gauge steel floor truss and roof truss components. B. Provide manufacturer s standard steel truss members, bracing, bridging, blocking, reinforcements, fasteners and accessories with each type of steel framing required, as recommended by the manufacturer for the applications indicated and as needed to provide a complete light gauge cold formed steel truss system MATERIALS A. Materials: 1. All component gauges: Fabricate components of structural quality steel sheet per ASTM A653 with a minimum yield strength of 50,000 psi. 2. Bracing, bridging and blocking members: Fabricate components of commercial quality steel sheet per ASTM A653 with a minimum yield strength of 33,000 psi. B. Ultra-Span steel truss components: Provide sizes, shapes and gages indicated. 1. Design Uncoated-Steel Thickness:20 gauge, inch (0.91 mm). 2. Design Uncoated-Steel Thickness:18 gauge, inch (1.20 mm). 3. Design Uncoated-Steel Thickness:16 gauge inch (1.52 mm). 4. Design Uncoated-Steel Thickness:14 gauge, inch (1.90 mm). C. Finish: Provide components with protective zinc coating complying with ASTM A653, minimum G60 coating. D. Fastenings: 1. Manufacturer recommended self-drilling, self-tapping screws with corrosion-resistant plated finish. Fasteners shall be of sufficient size and number to ensure the strength of the connection. 2. Welding: Comply with AWS D1.1 when applicable and AWS D1.3 for welding base metals less than 1/8 thick. 3. Other fasteners as accepted by truss engineer FABRICATION A. Factory fabricate cold-formed steel trusses plumb, square, true to line, and with connections securely fastened, according to manufacturer s recommendations and the requirements of this Section. 1. Fabricate truss assemblies in jig templates. 2. Cut truss members by sawing or shearing or plasma cutting. 3. Fasten cold-formed steel truss members by welding or screw fastening, or other methods as standard with fabricator. Wire tying of framing members is not permitted. a. Comply with AWS requirements and procedures for welding, appearance and quality of welds, and methods used in correcting welding work. b. Locate mechanical fasteners and install according to coldformed steel truss component manufacturer s instructions with screw penetrating joined members by not less than 3 exposed screw threads. B. Care shall be taken during handling, delivery and erection. Brace, block, or reinforce truss as necessary to minimize member and connection stresses. C. Fabrication Tolerances: Fabricate trusses to a maximum allowable tolerance variation from plumb, level, and true to line of 1/8 inch in 10 feet (1:960) and as follows: 1. Spacing: Space individual trusses no more than plus or minus 1/8 inch (3mm) from plan location. Cumulative error shall not exceed minimum fastening requirements of sheathing or other finishing materials. 2. Squareness: Fabricate each cold-formed steel truss to a maximum out-of-square tolerance of 1/8 inch (3mm). PART 3 EXECUTION 3.01 EXAMINATION A. Examine structure, substrates and installation conditions. Do not proceed with cold-formed steel truss installation until unsatisfactory conditions have been corrected. B. Installation constitutes acceptance of existing conditions and responsibility for satisfactory performance INSTALLATION, GENERAL A. General: 1. Erection of trusses, including proper handling, safety precautions, temporary bracing and other safeguards or procedures are the responsibility of the Contractor and Contractor s installer. 2. Exercise care and provide erection bracing required to prevent toppling of trusses during erection. B. Erect trusses with plane of truss webs vertical and parallel to each other, accurately located at design spacing indicated. C. Provide proper lifting equipment suited to sizes and types of trusses required, applied at lift points recommended by truss fabricator. Exercise care to avoid damage to truss members during erection and to keep horizontal bending of the trusses to a minimum. D. Provide framing anchors as indicated or accepted on the engineering design drawing or erection drawings. Anchor trusses securely at bearing points. E. Install roof framing and accessories plumb, square, true to line, and with connections securely fastened, according to manufacturer s recommendations. 1. DO NOT cut truss members without prior approval of truss engineer. 2. Fasten cold-formed steel roof framing by welding or screw fastening, as standard with fabricator. Wire tying of roof framing is not permitted. a. Comply with AWS requirements and procedures for welding, appearance and quality of welds, and methods used in correcting welding work. b. Locate mechanical fasteners and install according to coldformed roof framing manufacturer s instructions with screw penetrating joined members by not less than 3 exposed screw threads. 14
17 ULTRA-SPAN c. Install roof framing in one-piece lengths, unless splice connections are indicated. d. Provide temporary bracing and leave in place until trusses are permanently stabilized. F. Erection Tolerances: Install trusses to a maximum allowable tolerance variation from plumb, level, and true to line of 1/8 inch in 10 feet (1:960) and as follows: a. Space individual trusses no more than plus or minus 1/8 inch (3 mm) from plan location. Cumulative error shall not exceed minimum fastening requirements of sheathing or other finishing materials OPEN WEB FLOOR TRUSS INSTALLATION A. Install perimeter joist track or belly band sized to match trusses. Align and securely anchor or fasten track to supporting structure at corners, ends, and spacing indicated or as recommended by the manufacturer. B. Install trusses bearing on supporting framing, level, straight, and plumb, adjust to final position, brace, and reinforce. 1. Install trusses over supporting framing with a minimum end bearing of 1-1/2 inches (38mm). 2. Reinforce ends of trusses with web stiffeners, end clips, joist hangers, steel clip angles, steel-stud sections, or as otherwise recommended by manufacturer. C. Space trusses not more than 2 inches (51 mm) from abutting walls, and as follows: 1. Truss Spacing: 12 inches (305 mm). 2. Truss Spacing: 16 inches (406 mm). 3. Truss Spacing: 24 inches (610 mm). 4. Truss Spacing: As indicated. D. Frame openings with built-up joist headers consisting of joist and joist track, nesting joists, or another combination of connected joists where indicated. E. Install truss reinforcement at interior supports with single, short length of joist section located directly over interior support, with lapped joists of equal length to joist reinforcement, or by other method recommended by joist manufacturer. F. Install bridging at each end of trusses and at intervals indicated. Fasten bridging at each truss intersection as follows: 1. Bridging: Cold-rolled steel channel, fastened to bottom flange of trusses. 2. Bridging: Flat, steel-sheet straps of width and thickness indicated, fastened to bottom flange of trusses. 3. Bridging: Combination of flat, steel-sheet straps of width and thickness indicated and joist-track solid blocking of width and thickness indicated. Fasten flat straps to bottom flange of trusses and secure solid blocking to joist webs. G. Secure trusses to load-bearing interior walls to prevent lateral movement of bottom flange. H. Install miscellaneous truss framing and connections, including web stiffeners, closure pieces, clip angles, continuous angles, hold-down angles, anchors, and fasteners, to provide a complete and stable joist-framing assembly ROOF TRUSS INSTALLATION A. Install, bridge, and brace trusses according to manufacturer s recommendations and requirements of this Section. B. Space trusses as follows: 1. Truss Spacing: 16 inches (406 mm). 2. Truss Spacing: 24 inches (610 mm). 3. Truss Spacing: 32 inches (813 mm). 4. Truss Spacing: 48 inches (1220 mm). C. Do not alter, cut, or remove truss members or connections of truss members. D. Erect trusses with plane of truss webs plumb and parallel to each other, align, and accurately position at spacing indicated. E. Erect trusses without damaging truss members or connections. F. Align truss bottom chords with load-bearing studs or continuously reinforce track to transfer loads to structure. Anchor trusses securely at all bearing points. G. Install continuous bridging and permanent truss bracing per truss design requirements. H. Install necessary roof cross and diagonal bracing per design professional recommendations REPAIRS AND PROTECTION A. Galvanizing Repairs: Prepare and repair damaged galvanized coatings on fabricated and installed cold-formed steel framing with galvanizing repair paint according to ASTM A 780 and the manufacturer s instructions. 15
18 FIRE RESISTANCE RATINGS 1 Design No. P *Bearing the UL Classification Marking Restrained Assembly Rating: 1 and 1-1/2 hr. - (See Items 5, 5A and 5B) Unrestrained Assembly Rating: 1, 1-1/2 hr. and 2 hr. - (See Items 5, 5A, & 5B) 1. Structural Steel Members* Pre-fabricated light gauge steel truss system consisting of cold-formed, galvanized steel chord and web sections. Trusses fabricated in various sizes, depths, and from various steel thickness. Trusses spaced a max of 48 in. OC. AEGIS METAL FRAMING L L C Ultra-Span, Pre-fabricated Light Gauge Steel Truss System 2. Bridging (Not Shown) Location of lateral bracing for truss chord and web sections to be specified on truss engineering. 3. Steel Floor and Form Units (Classified or Unclassified) Corrugated or fluted steel form units, min 22 MSG painted or galv steel, welded or mechanically fastened max 12 in. OC to truss-top chords. 3A. Steel Floor and Form Units* As an alternate to Item 3 - min 25 MSG, 15/16 in. deep, painted or galv units welded or mechanically fastened max 12 in. OC to the top chord of trusses. When used, max hourly rating is reduced to 1 hr. LOADMASTER SYSTEMS INC Types HD, ED or PS. 4. Cementitious Backer Units* Nom 1/2 or 5/8 in. thick sheets. End-joists to occur over crests of steel roof deck with end-joints staggered in adjacent rows. Units loosely laid, adhered or mechanically attached to steel roof deck. UNITED STATES GYPSUM CO Durock Exterior Cement Board or Durock Cement Board. 4A. Gypsum Board (Classified or Unclassified) (Not Shown) As an alternate to Item 4, Gypsum sheathing, min 1/2 in. thick, applied perpendicular to steel roof deck. End joints to occur over crests of steel roof deck. Sheathing loosely laid, adhered or mechanically attached to steel roof deck. See Gypsum Board (CKNX) category for names of Classified companies. 5. Roof Insulation Foamed Plastic* Any polyisocyanurate foamed plastic insulation boards bearing the UL Classification Marking. Min thickness is 1 in. for the 1 hr assembly ratings, 2 in. for the 1-1/2 hr assembly ratings and 4 in. for the 2 hr ratings, with no limit on max overall thickness. Boards installed over the cementitious backer units (Item 4) or gypsum sheathing (Item 4A), with the end-joints staggered in adjacent rows. When applied in more than one layer, each layer of board to be offset in both directions from layer below in order to lap all joints. Boards loosely laid, adhered or mechanically fastened to cementitious backer units or gypsum sheathing, and to steel roof deck (Item 3). See Foamed Plastic (CCVW) Category in the Fire Resistance Directory. 5A. Roof Insulation Foamed Plastic* (Not Shown) As an alternate to Item 5 For 1 and 1-1/2 hr ratings only Any polystyrene foamed plastic insulation boards bearing the UL Classification Marking. Min thickness is 1 in. for the 1 hr assembly ratings, and 2 in. for the 1-1/2 hr assembly ratings, with no limit on max overall thickness. Boards installed over the cementitious backer units (Item 4) or gypsum sheathing (Item 4A), with the end-joints staggered in adjacent rows. When applied in more than one layer, each layer or board to be offset in both directions from layer below in order to lap all joints. Boards loosely laid, adhered or mechanically fastened to cementitious backer units or gypsum sheathing, and to steel roof deck (Item 3). See Foamed Plastic (BRYX) category in the Building Materials Directory or Foamed Plastic (CCVW) category in the Fire Resistance Directory. 5B. Roof Insulation Mineral and Fiber Boards* (Not Shown) As an alternate to Item 5 Mineral wool, glass fiber or perlite insulation boards, 24 by 48 in. min size, applied in one or more layers. Min thickness is 1 in. for the 1 hr assembly ratings, 2 in. for the 1-1/2 hr assembly rating and 4 in. for the 2 hr ratings, with no limit on max overall thickness. Boards installed over the cementitious backer units (Item 4) or gypsum sheathing (Item 4A), with the end-joints staggered in adjacent rows. When applied in more than one layer, each layer of board to be offset in both directions from layer below in order to lap all joints. Boards loosely laid, adhered or mechanically fastened to cementitious backer units or gypsum sheathing, and to steel roof deck (Item 3). See Mineral and Fiber Boards (BQXR) Category in the Building Materials Directory or Mineral and Fiber Boards (CERZ) Category in the Fire Resistance Directory. 5C. Roof Insulation Building Units* (Not Shown) As an alternate to Item 5 Any polyisocyanurate foamed plastic insulation faced on the top surface with oriented strand board or faced on the underside or both sides with wood fiber board, bearing the UL Classification Marking for Fire Resistance. No min thickness of the polyisocyanurate foamed plastic core required for the 1 hr assembly ratings, min 2 in. polyisocyanurate foamed plastic core for the 1-1/2 hr assembly ratings and min 4 in. polyisocyanurate foamed plastic core for the 2 hr rating with no limit on max overall thickness. Boards installed over the cementitious backer units (Item 4) or gypsum sheathing (Item 4A), with the end-joints staggered in adjacent rows. When applied in more than one layer, each layer of board to be offset in both directions from layer below in order to lap all joints. Boards loosely laid, adhered or mechanically fastened to cementitious backer units or gypsum sheathing and to steel roof deck (Item 3). See Building Units (BZXX) category in the Fire Resistance Directory. 6. Roof Covering* Consisting of hot-mopped or cold-application materials compatible with insulation(s) described herin which provide Class A, B or C coverings. See Roofing Materials and Systems Directory-Roof Covering Materials (TEVT). 4 8 UL Design P521 3 This design was reproduced from the original UL design Document. 6A. Roofing Membrane* (Not Shown) In lieu of Item 6, single-ply membrane that is either ballasted, adhered or mechanically attached to the insulation(s) described herin as permitted under the respective company's Classification. See Fire Resistance Directory-Roofing Membranes (CHCI) Category. 6B. Metal Roof Deck Panels* In Lieu of or in addition to Items 6 and 6A, the roof covering may consist of mechanically fastened galv or painted steel roof deck panels. Panels may be installed above a steel purlin assembly per metal roof deck manufacturer's specifications. Steel purlin assembly to be installed transverse to steel roof trusses (Item 1). A line of sealant or tape may be used at panel side and end laps. See Metal Roof Deck Panels Category in the Roofing Materials and Systems Directory (TJPV) or Fire Resistance Directory (CETW) for names of manufacturers. 6C. Roof Covering* In Lieu of Item 6 Any UL Class A, B or C Prepared Roof Covering (TFWZ) acceptable for use over plywood sheathing or nonveneer APA Rated Series Sheathing. Sheathing mechanically fastened through roof insulation to top chord of steel trusses with fasteners spaced a max of 12 in. OC. As an alternate to the plywood sheathing or nonveneer APA Rated Series Sheathing, the Prepared Roof Covering (TFWZ) may be applied directly to the Building Units* (Item 5C) if the building units also carry the UL Classification Marking for Prepared Roofing Accessories (TGDY). 7. Furring Channels Resilient channels formed of 25 MSG galv steel, installed perpendicular to the trusses (Item 1), spaced a max of 16 in. OC. Channels oriented opposite at wallboard butt-joints. Channel spices overlapped 4 in. beneath steel trusses. Channels secured to each truss with Type S-12 by 1/2 in. long screws. 7A. Furring Channels (Not Shown) As an alternate to Item 7 Hat chanels min 20 MSG galv steel, min 2-5/8 in. wide by min 7/8 in. deep, installed perpendicular to the trusses (Item 1) spaced a max of 16 in. OC. Two courses of channel positioned 6 in. OC, 3 in. from each end of wallboard. Channel splices overlapped 6 in. beneath steel trusses. Channels secured to each truss with No. 18 SWG steel wire double strand saddle ties. Channels tied together with double strand of No.18 SWG steel wire at each end overlap. 7B. Furring Channels As an alternate to Items 7 and 7A, resilient channels, double legged formed of 25 MSG galv steel, 2-7/8 in. wide by 1/2 in. deep, spaced max 16 in. OC, perpendicular to steel trusses. Two courses of resilient channel positioned 6 in. OC at wallboard butt-joints (3 in. from each end of wallboard). Channel splices overlapped 4 in. beneath steel trusses. Channels secured to each truss with Type S12 by 1/2 in. long screws or with No. 18 SWG galv steel wire double strand saddle ties. Channels tied together with double strand of No. 18 SWG galv steel wire at each end of overlap. 8. Gypsum Board* For all ratings except the 2 Hr Assembly Ratings One layer of nom 5/8 in. thick by 48 in. wide boards, installed with long dimension parallel to trusses. Attached to the resilient channels using 1 in. long Type S bugle-head screws spaced 12 in. OC along butted end-joints and 12 in. OC in the field. For the 2 Hr Ratings Two layers of nom 5/8 in. thick by 48 in. wide boards, installed with long dimension parallel to trussses. Base layer attached as described above. Face layer attached to the resilient channels using 1-5/8 in. long Type S bugle-head screws spaced 12 in. OC along butted end-joints and 12 in. OC in the field. Screws staggered from base layer screws. Face layer side and end joints offset a minimum 16 in. from base layer side and end joints. CANADIAN GYPSUM COMPANY Types C, IP-X2, IPC-AR. UNITED STATES GYPSUM CO Types C, IP-X2, IPC-AR. USG MEXICO S A DE C V Types C, IP-X2, IPC-AR. 9. Finishing System (Not Shown) Vinyl, dry of premixed joint compound, applied in two coats to joints and screw heads, paper tape, 2 in. wide, embedded in first layer of compound over all joints. Alternate Ceiling Membrane Not shown. 10. Steel Framing Members a. Main runners Installed perpendicular to Structural Steel Members Nom 10 or 12 ft long, 15/16 in. or 1-1/2 in. wide face, spaced 4 ft OC. Main runners hung a min of 2 in. from bottom chord of Structural Steel Members with 12 SWG galv steel wire. Wires located a max of 48 in. OC. b. Cross tees or channels Nom 4 ft long, 15/16 in. or 1-1/2 in. wide face or cross channels, nom 4 ft long, 1-1/2 in. wide face, installed perpendicular to the main runners, spaced 16 in. OC. Additional cross tees or channels used at 8 in. from each side of butted wallboard end joints. The cross tees or channels may be riveted or screw-attached to the wall angle or channel to facilitate the ceiling installation. c. Wall angles or channels Used to support steel framing member ends and for screw-attachment of the gypsum wallboard Min in. thick painted or galvanized steel angle with 1 in. legs or min in.thick painted or galvanized steel channel with a 1 by 1-1/2 by 1 in. profile, attached to walls at perimeter of ceiling with fasteners 16 in. OC. CGC INTERIORS, DIV OF CGC INC Type DGL or RX. USG INTERIORS INC Type DGL or RX. 11. Gypsum Board* For use with Steel Framing Members (Item 10) - For the 1 and 1-1/2 hr ratings - One layer of nom 5/8 in. thick by 48 in. wide boards, installed with long dimension parallel to the main runners. Wallboard fastened to each cross tee or channel with five wallboard screws, with one screw located at the midspan of the cross tee or channel, one screw located 12 in. from and on each side of the cross tee or channel mid span and one screw located 1-1/2 in. from each wallboard side joint. Except at wallboard end joints, wallboard screws shall be located on alternating sides of cross tee flange. At wallboard end joints, wallboard screws shall be located 1/2 in. from the joint. Wallboard fastened to main runners with wallboard screws 1/2 in. from side joints, midway between intersections with cross tees or channels (16 in. OC). End joints of adjacent wallboard sheets shall be staggered not less than 32 in. Wallboard sheets screw attached to leg of wall angle with wallboard screws spaced 12 in. OC. Joints treated as described in Item 8. For the 2 hr rating - Two layers of nominal 5/8 in. thick by 48 in. wide boards. Inner layer installed with long dimension perpendicular to cross tees with side joints centered along main runners and end joints centered along cross tees. Inner layer fastened to cross tees with 1-1/4 in. long Type S bugle-head steel screws spaced 8 in. OC along buted end joints and 12 in. OC in the field of the board. End joints of adjacent wallboard sheets shall be staggered not less than 4 ft OC. Outer layer attached to the cross tees through inner layer using 1-7/8 in. long Type S bugle-head steel screws spaced 8 in. OC at butted end joints and 12 in. OC in the field. Butted end joints to be centered along cross tees and be offset a min of 32 in. from end joints of inner layer. Rows of screws on both sides of butted end joints of each layer shall be located 3/8 to 1/2 in. from end joints. Butted side joints of outler layer to be offset a min of 18 in. from butted side joints of inner layer. Joints treated as described in Item 8. CANADIAN GYPSUM COMPANY Type C or IP-X2 UNITED STATES GYPSUM CO Type C or IP-X2 USG MEXICO S A DE C V Type C or IP-X2 16
19 FIRE RESISTANCE RATINGS 1 Design No. P UL Design P521 *Bearing the UL Classification Marking This design was reproduced from the original UL design Document. Restrained Assembly Rating 1 and 1-1/2 hr. Unrestrained Assembly Rating 1 hr. 1. Structural Steel Members* Pre-fabricated light-gauge steel truss system consisting of cold-formed, galvanized steel chord and web sections. Trusses fabricated in various sizes, depths and from various steel thicknesses. Trusses spaced a max of 48 in. OC. AEGIS METAL FRAMING L L C Ultra-Span, Pre-fabricated Light Gauge Steel Truss System 2. Bridging (Not Shown) Location of lateral bracing for truss chord and web sections to be specified on truss engineering. 3. Roof system* Any UL Class A, B or C Roofing System (TGFU) or Prepared Roof Covering (TFWZ) acceptable for use over nom 23/32 in. thick wood structural panels, min grade "C-D" or "Sheathing". Nom 23/32 in. thick wood structural panels mechanically fastened to top chord of steel trusses with fasteners spaced a max of 12 in. OC. As an option, the wood structural panels may be installed to min 20 ga. steel purlins or steel hat channels. Steel purlins or hat channels to be spaced a max 24 in. OC and welded or mechanically fastened, transverse to steel roof trusses (Item 1). 3A. Steel Roof Deck Not Shown In lieu of, or in addition to the wood structural panels described in Item 3, the steel roof deck may consist of corrugated or fluted steel form units, minimum 9/16 in. deep, 22 MSG painted or galv steel, welded or mechanically fastened at a max. 12 in. OC to the top chord of the roof trusses (Item 1). When used in addition to the wood structural panels described in Item 3, Batts and Blankets (Item 8) is optional. When used lieu of the wood structural panels described in Item 3, Batts and Blankets (Item 8) must be used and the Class A, B or C Roofing System must include a min 3/4 in. thickness of roof insulation or 1/2 in. thickness of Classified or unclassified gypsum boards. If polystyrene roof insulation is used, it must be installed on top of a min 1/2 in. thickness of Classified or unclassified gypsum boards. 3B. Steel Floor and Form Units* As an alternate to Item 3A min 25 MSG painted or galv units welded or mechanically fastened max 12 in. OC to the top chord of trusses (Item 1). When used in addition to the wood structural panels described in Item 3, Batts and Blankets (Item 8) is optional. When used lieu of the wood structural panels described in Item 3, Batts and Blankets (Item 8) must be used and the Class A, B or C Roofing System must include a min 3/4 in. thickness of roof insulation or 1/2 in. thickness of Classified or unclassified gypsum boards. If polystyrene roof insulation is used, it must be installed on top of a min 1/2 in. thickness of Classified or unclassified gypsum boards. LOADMASTER SYSTEMS INC Types HD, ED or PS. 4. Vapor Barrier (Not Shown) Optional Commercial asphalt saturated felt, in. thick, applied over the wood structural panels. 5. Furring Channels Resilient channels formed of 25 MSG galv steel, installed perpendicular to the steel trusses (Item 1), spaced a max of 16 in. OC when no insulation (Item 8 or 8A ) is fitted in the concealed space, or a max of 12 in. OC when insulation (Item 8 or 8A ) is fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. Two courses of resilient channel positioned 6 in. OC at wallboard butt-joints (3 in. from each end of wallboard). Channels oriented opposite at wallboard butt-joints. Channel splices overlapped 4 in. beneath steel trusses. Channels secured to each truss with Type S12 by 1/2 in. long screws. 5A. Furring Channels (Not Shown) As an alternate to Item 5 Hat channels min 20 MSG galv steel, min 2-5/8 in. wide by min 7/8 in. deep, installed perpendicular to the trusses (Item 1) spaced a max of 16 in. OC. When no insulation (Item 8 or 8A) is fitted in the concealed space, or a max 12 in. OC when insulation (Item 8 or 8A) is fitted in the concealed space, draped over the hat channel/gypsum board ceiling membrane. Two courses of channel positioned 6 in. OC, 3 in. from each end of wallboard. Channel splices overlapped 6 in. beneath steel trusses. Channels secured to each truss with No. 18 SWG steel wire double strand saddle ties. Channels tied together with double strand of No. 18 SWG steel wire at each end overlap. 5B. Furring Channels As an alternate to Items 5 and 5A, resilient channels, double legged formed of 25 MSG galv steel, 2-7/8 in. wide by 1/2 in. deep, installed perpendicular to the trusses (Item 1) spaced max 16 in. OC when no insulation (Item 8 or 8A ) is fitted in the concealed space, or a max of 12 in. OC when insulation (Item 8 or 8A ) is fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. Two courses of resilient channel positioned 6 in. OC at wallboard butt-joints (3 in. from each end of wallboard). Channel splices overlapped 4 in. beneath steel trusses. Channels secured to each truss with Type S12 by 1/2 in. long screws or with No. 18 SWG galv steel wire double strand saddle ties. Channels tied together with double strand of No. 18 SWG galv steel wire at each end of overlap. 6. Gypsum Board* For the 1 Hr. Ratings - One layer of nom 5/8 in. thick by 48 in. wide boards, installed with long dimension parallel to trusses. Attached to the resilient channels using 1 in. long Type S bugle-head screws. Screws spaced a max of 12 in. OC along butted end-joints and in the field when no insulation (Item 8 or 8A ) is fitted in the concealed space or a max of 8 in. OC along butted end-joints and in the field when insulation (Item 8 or 8A ) is fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. For the 1-1/2 Hr. Ratings - Two layers of nom 5/8 in. thick by 48 in. wide boards, installed with long dimension parallel to trusses. Base layer attached to the resilient channels using 1 in. long Type S bugle-head screws spaced a max of 8 in. OC along butted end-joints and in the field. Face layer attached to the resilient channels using 1-5/8 in. long Type S bugle-head screws spaced a max of 8 in. OC along butted endjoints and in the field. Screws staggered from base layer screws. Face layer side and end joints offset a min 16 in. from base layer side and end joints. CANADIAN GYPSUM COMPANY Types C, IP-X2, IPC-AR. UNITED STATES GYPSUM CO Types C, IP-X2, IPC-AR. USG MEXICO S A DE C V Types C, IP-X2, IPC-AR. 7. Finishing System (Not shown) Vinyl, dry or premixed joint compound, applied in two coats to joints and screw-heads; paper tape, 2 in. wide, embedded in first layer of compound over all joints. As an alternate, nom 3/32 in. thick veneer plaster may be applied to the entire surface of gypsum wallboard. 8. Batts and Blankets* Optional for the 1 Hr. Ratings - Any thickness mineral wool or glass fiber insulation bearing the UL Classification Marking for Surface Burning Characteristics, having a flame spread value of 25 or less and a smoke spread value of 50 or less. Insulation fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. Mandatory for the 1-1/2 Hr. Ratings-Min 9-1/2 in. thick glass fiber insulation bearing the UL Classification Marking for Surface Burning Characteristics, having a flame spread value of 25 or less and a smoke spread value of 50 or less. Insulation fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. 8A. Loose Fill Material* As an alternate to Item 8 Optional for the 1 Hr. Ratings Any thickness of loose fill material bearing the UL Classification Marking for Surface Burning Characteristics, having a flame spread value of 25 or less and a smoke spread value of 50 or less. Insulation fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. Mandatory for the 1-1/2 Hr. Ratings - Min 9-1/2 in. thickness of loose fill material bearing the UL Classification Marking for Surface Burning Characteristics, having a flame spread value of 25 or less and a smoke spread value of 50 or less. Insulation fitted in the concealed space, draped over the resilient channel/gypsum wallboard ceiling membrane. Alternate Ceiling Membrane Not Shown. 9. Steel Framing Members a. Main Runners Installed perpendicular to Structural Steel Members Nom 10 or 12 ft long, 15/16 in. or 1-1/2 in. wide face, spaced 4 ft OC. Main runners hung a min of 2 in. from bottom chord of Structural Steel Members with 12 SWG galv steel wire. Wires located a max of 48 in. OC. b. Cross tees or channels Nom 4 ft long, 15/16 in. or 1-1/2 in. wide face, or cross channels, nom 4 ft long, 1-1/2 in. wide face, installed perpendicular to the main runners, spaced 16 in. OC. Additional cross tees or channels used at 8 in. from each side of butted wallboard end joints. The cross tees or channels may be riveted or screw-attached to the wall angle or channel to facilitate the ceiling installation. c. Wall angles or channels Used to support steel framing member ends and for screw-attachment of the gypsum wallboard Min in. thick painted or galvanized steel angle with 1 in. legs or min in.thick painted or galvanized steel channel with a 1 by 1-1/2 by 1 in. profile, attached to walls at perimeter of ceiling with fasteners 16 in. OC. CGC INTERIORS, DIV OF CGC INC Type DGL or RX USG INTERIORS INC Type DGL or RX 10. Gypsum Board* For use with Steel Framing Members (Item 9) when Batts and Blankets* (Item 8) are not used - One layer of nominal 5/8 in. thick by 48 in. wide boards, installed with long dimension parallel to the main runners. Wallboard fastened to each cross tee or channel with five wallboard screws, with one screw located at the midspan of the cross tee or channel, one screw located 12 in. from and on each side of the cross tee or channel mid span, and one screw located 1-1/2 in. from each wallboard side joint. Except at wallboard end joints, wallboard screws shall be located on alternating sides of cross tee flange. At wallboard end joints, wallboard screws shall be located 1/2 in. from the joint. Wallboard fastened to main runners with wallboard screws 1/2 in. from side joints, midway between intersections with cross tees or channels (16 in. OC). End joints of adjacent wallboard sheets shall be staggered not less than 32 in. Wallboard sheets screw attached to leg of wall angle with wallboard screws spaced 12 in. OC. Joints treated as described in Item 7. For use with Steel Framing Members* (Item 9) when Batts and Blankets* (Item 8) are used - Ratings limited to 1 Hour- 5/8 in. thick, 4 ft wide; installed with long dimension perpendicular to cross tees with side joints centered along main runners and end joints centered along cross tees. Fastened to cross tees with 1 in. long steel wallboard screws spaced 8 in. OC in the field and 8 in. OC along end joints. Fastened to main runners with 1 in. long wallboard screws spaced midway between cross tees. Screws along sides and ends of boards spaced 3/8 to 1/2 in. from board edge. End joints of the sheets shall be staggered with spacing between joints on adjacent boards not less than 4 ft OC. CANADIAN GYPSUM COMPANY Type C, IP-X2, IPC-AR UNITED STATES GYPSUM CO Type C, IP-X2, IPC-AR USG MEXICO S A DE C V Type C, IP-X2, IPC-AR 17
20
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)
Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
Handling, Erection and Bracing of Wood Trusses
Handling, Erection and Bracing of Wood Trusses Follow these guidelines for safe installation of Wood Trusses. These guidelines should not be considered to be the only method for erecting and bracing of
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
Section A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
CPA Steel Stud Framing Page 1 of 11
CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
H-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version
CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
Introduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Bracing Webs in Trusses that have Dissimilar Configurations
Bracing Webs in Trusses that have Dissimilar Configurations Released April 25, 2006 Issue: Truss Design Drawings (TDD) that are prepared in accordance with ANSI/TPI 1, National Design Standard for Metal
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
8/18/14. Introduction to. Framing. Terminology and Concepts
8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"
Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL" Design/System/Construction/Assembly Usage Disclaimer Authorities
Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
The better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council RETAINED ON U.S.
ICC-ES Legacy Report ER-5043* Reissued March 2004 www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code DIVISION: 09
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems
The Butler MR-24 Standing Seam Roof Difference A comparison between metal roof systems Roof Systems Necessities Weathertight (don t leak!) Low maintenance Weathertightness Roof clips, seams, panel alignment
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
AUTHORIZATION TO MARK
AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set
SUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
Common Errors in Truss Design
In today s competitive world of trusses, component manufacturers are always looking for ways to generate more efficient truss designs. Occasionally, truss designs need to be changed in order to be sealed
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
COLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections
Materials Standard shapes W sections, C channels, Structural T, Angles, Pipes, Tubes, Rods and Plates Fabricated members, Built-up sections Adding plates to beam flanges, Stiffeners to beam webs Built
Protecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS The Underwriters Laboratories (U.L.) Fire Resistance Directory lists hundreds of assemblies their fire resistance ratings. The Specifying Professional can choose
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
ATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
VERTICAL LOCK Table of Contents
Table of Contents TABLE OF CONTENTS Vertical Lock Product Data Sheet... 2 Vertical Lock Engineering Data... 3 General Information... 6 Material Testing... 7 Panel Overview... 8 Handling Material & Storage
Retrofitting an Insulated Cold Roof
Retrofitting an Insulated Cold Roof As a metal-roofing contractor in the Upper Peninsula of Michigan, I am frequently asked to fix roof leaks that have less to do with roofing than with the way poorly
Shingle Installation Guide
Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of
GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC
UL 580 TEST REPORT Rendered to: ARMSTRONG WORLD INDUSTRIES SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC Report No.: Test Dates: 12/14/09 Through: 12/22/09 Report Date: 03/12/10 Expiration
Seismic Technical Guide
Technical Document Seismic Technical Guide Hanger Wire Attachment Code Requirements 1 The International Building Code (IBC) defines the requirement for hanger wire and their supports and attachment methods.
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
Design No. L556. Design No. L556
1 of 9 3/17/2015 6:15 PM Design No. L556 BXUV.L556 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted
1.02 SYSTEM DESCRIPTION
1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall
Code of Standard Practice for Timber Frame Structures
TFEC 2-2013 Code of Standard Practice for Timber Frame Structures August 2013 Preface This Code is intended to represent a reasonable consensus of what constitutes ordinary and acceptable practice within
Nucor VR16 II TM Vertical Rib Standing Seam Roof System
Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
Steel joists and joist girders are
THE STEEL CONFERENCE Hints on Using Joists Efficiently By Tim Holtermann, S.E., P.E.; Drew Potts, P.E.; Bob Sellers, P.E.; and Walt Worthley, P.E. Proper coordination between structural engineers and joist
Post and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
Protecting Your Home from Wind Damage
Protecting Your Home from Wind Damage During severe thunderstorms or hurricanes, homes may be damaged or destroyed by high winds. Debris flying through the air can break windows and doors, allowing high
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
Building Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
Design of Cold-Formed Steel Shear Walls
DESIGN GUIDE 2 Design of Cold-Formed Steel Shear Walls March 1998 The following publication was developed by R.L. Brockenbrough & Associates for the American Iron and Steel Institute (AISI), In the production
Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two
Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Factors governing type selection Economics not necessarily the one that requires the least structural
Formwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
Wood Truss Restraint and Bracing Guide
BUILDERS Wood Truss Restraint and Bracing Guide Using Simpson Strong Tie Products To Meet the Recommendations of the Building Component Safety Information (BCSI) Guide (800) 999-5099 www.strongtie.com
09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
HfHMD uses LP SmartSide siding and trim.
HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof. 1155 & 4155 LCL: Applies to all freight in less than container load quantities.
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
CHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010
Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775
The Analysis of Open Web Steel Joists in Existing Buildings
PDHonline Course S117 (1 PDH) The Analysis of Open Web Steel Joists in Existing Buildings Instructor: D. Matthew Stuart, P.E., S.E., F.ASCE, F.SEI, SECB, MgtEng 2013 PDH Online PDH Center 5272 Meadow Estates