Fire Resisting Rolling Shutters & Doors
|
|
|
- Laurel Welch
- 9 years ago
- Views:
Transcription
1 Fire Resisting Rolling Shutters & Doors
2 Fire Resisting Rolling Shutters What is a fire resisting rolling shutter? A traditional single skin fire resisting rolling shutter looks and operates in a similar way to a standard steel rolling shutter. The physical differences are that the materials used are heavier and there are more fixings required. Syston Doors can also provide alternative physical fire shutter products as shown in this brochure. Fire Shutter Structural Recommendations The structure supporting the rolling shutter must be a fire resistant separating element (to BS476, Part 20, 21, 22, 1987), having a fire resistance equal or greater than that required of the rolling shutter itself and must be capable of supporting the rolling shutter for the required fire resistance period without compromising the fire performance of the rolling shutter. Consideration must be given to the loads imposed by the various rolling shutter components, i.e. end plates and the barrel support brackets. Fixing to Masonry Openings. Opening to be constructed from masonry, reinforced concrete or dense concrete blocks (7 Nm and above) and have a fire resistance equal or greater to that of the door. Lightweight and hollow blocks are NOT suitable. All concrete/masonry elements must be designed in accordance with BS5628: Part 3:1985 and have a density of > 600kg/m 3. Lintels spanning the structural opening should comply with BS8810: Part 1:1997. Client to ensure that openings are plumb and square and that the structure will accept rawlbolt type fixings without cracking. Subject to the fire shutter being fitted to a flat surface, gaps of up to 6mm are acceptable (for a distance of 150mm), but if, due to an uneven structural finish, larger gaps are apparent, they must be sealed with a suitable fire retardant material, e.g. plaster, fire retardant mastic seal (non-intumescent). Syston Doors do not include this sealing. Fixing to Steel Openings Where fire resisting rolling shutters are fitted to steel, the steel must be insulated and thermal bridging effects considered where insulation has been breached. It is recommended that a critical steel temperature of C and steel sections with an Hp/A below 230m-1 are used for designing fire resisting steel supporting structures. Fixing to Timber Partitions Fire resisting rolling shutters can be fixed to non-loadbearing timber framed or steel framed partitions (with suitable timber inserts all round) up to 2750mm wide x 3250mm high, (maximum area 10m 2 ), for up to 60 minutes under cover of BRE test certificate FG 7941 N. The opening must be capable of carrying the weight of the shutter and be equal or greater than the fire resistance of the rolling shutter assembly. It is most important that the Contractor adheres to the opening construction details, as these are also covered by the assessment and as such become the CONTRACTOR S RESPONSIBILITY. Fire testing We do not as standard include for a return journey involving a fire test after the original installation. We can include this at extra cost. Maintenance Please note that it is a requirement under Regulatory Reform (Fire Safety) Order 2005, that fire resisting Rolling Shutters are tested every six months. Full width access should therefore be maintained to the shutter to enable this to be carried out. Syston Doors can offer routine testing and maintenance contracts on application. If no contract is entered into we cannot take any responsibility for the working condition of the shutters after the guarantee period. Fire Shutters over fire exits and escape routes Appendix B of the Buildings Regulations Approved Document B states that roller shutters across a means of escape should only be released by a heat sensor, such as a fusible link or electric heat detector, in the immediate vicinity of the door. Closure of shutters in such locations should not be initiated by smoke detectors or a fire alarm system, unless the shutter is also intended to partially descend to form part of a boundary to a smoke reservoir. Note Removable guides, bottom rubber seals, brush seals, safety edges and wicket gates cannot be fitted to fire shutters. 2
3 Shutter shown with optional key lock 76mm laths 50mm laths Flame Shield 120 Tubular Motor Operated Fire Shutter Application Flameshield v single phase tubular motor operated fire shutters provide an attractive and space friendly fire shutter solution with a fire resistance as standard of up to 120 minutes (2 hours) and for openings up to 4800mm wide x 1900mm high (see size grid). The shutter is constructed to Warrington Fire Research Centre WARRES No , the test is in accordance with clause 8 of BS476 Part 22. The attractive 50mm flat faced lath for openings up to 3500mm wide x 2500mm high, make it most suitable for servery type openings or where aesthetic appearance is important. Over this size a traditional 76mm curved lath is used, but still offers the benefits of a space friendly coil casing and guide detail. General Specification Curtain Shutter curtains are constructed from 50mm flat faced laths up to 3500mm wide x 2500mm high or 76mm traditional curved laths over this size, with a standard Tee bottom rail. (If smaller openings are adjacent to larger openings the laths on the smaller openings would normally be 76mm to ensure all match). Hood (Coil Casing) A profiled galvanised sheet steel hood is included as standard. A fascia can be included at extra cost on fit within applications. Dependent on the fire rating of the shutter and the size of the opening, the shutter could require a hood support bracket. 3
4 Guides Vertical guides are fabricated from 50mm deep galvanised steel channels. Wider openings will use 65mm deep channels. Finish Standard finish is, curtain, bottom rail, guides & hood galvanised, end plates and fixing angles are finished in one coat of primer paint. Powder coated finish to a standard range of BS/RAL colours available at extra cost. Locking A lock is not normally included. A centre bottom rail key lock which sends a bolt into each side guide can be included at extra cost. Operation Powered by a single phase 240v tubular motor with normal day to day operation of the shutter by rocker switch. Manual override by hand crank can be included at extra cost. Available Modes of Activation Fusible Link release On activation of the fusible link from a local heat source of 68 C, this will send a signal to the relay which will signal the shutter to power down from the maintained supply or alternatively from the optional battery back up unit. Fire Alarm link By use of a fire alarm relay the shutter will close under power. The unit will require a maintained supply or alternatively we can supply with a Battery Back Up unit. Volt free fire alarm signal required. Syston Doors do not include for connecting into the fire alarm system. Audio Visual Warning Closure For use when an audio & visual warning is required of the shutter closing. The unit also includes a facility for a delayed closing of the shutter. The fire alarm signal is connected directly into this unit. On activation from the fire alarm the unit starts to flash & sound with the shutter closing after a pre-determined delay ( seconds). Fixing to Partitions Flameshield 120 can be fixed to non-loadbearing timber framed or steel framed partitions (with suitable timber inserts all round) up to 2750mm wide x 3250mm high (maximum area 10m 2 ) up to 60 minutes under cover of the above certification. For larger openings see our Flame Shield 240 range of fire shutters. Clear Height Sizes available for Flame Shield 120 Clear Width mm flat laths within yellow area or 75mm traditional (curved) laths 75mm Traditional(curved) laths 4
5 Technical Information Flame Shield 120 Door Weight Typically 30 kg/m 2. Face Fitted Fit Within Minimum width available is 800mm overall end plates. Full width access to be maintained for future service and maintenance. 5
6 Flame Shield 240 Electrically Operated Fire Shutter Application Designed for use where the tube motor operated fire shutter is not suitable and providing 30, 60, 120 or 240 minutes of protection from fire this shutter has been tested to BS476 Part 22. Flame Shield 240 provides fire protection for all uses including department stores, shopping centres, warehouses, factories, schools and all other areas where protection from the spread of fire is required. Fixing to Partitions Flame Shield 240 can be fixed to non-load bearing timber or steel framed partitions (with suitable timber inserts all round) up to 2750mm wide x 3250mm high (Maximum area 10m 2 ) up to 60 minutes. General Specification Curtain Shutter curtains are constructed from 76mm curved section steel laths, which are securely held in place by end locks. Lath thickness vary dependant on opening size and fire rating. Bottom rails are roll formed galvanised Tee sections. Hood (Coil Casing) All fire shutters as standard include a galvanised sheet steel hood (coil casing). A motor cover will be included on all shutters under 2500mm high and optionally over this height. Guides 65mm x 3mm (minimum) mild steel channels mounted on rolled steel angles. Endplates Mild steel of appropriate thickness relative to door size. 6
7 Type of Operation Hand Chain Available up to 4000mm wide x 4000mm and suitable for applications where the shutter is held open, closing only in the event of a fire. Manual closing is achieved by releasing a pull cord, which allows a controlled descent via a gear unit at approximately 100mm/second. Operating by the hand chain is a slow process and power operation is recommended when everyday use is required. Electric Suitable for all sizes of shutter, the motor is either single phase (240 Volt 50 Hz) or 3 phase (415 Volt 50 Hz) dependant on size of door. A controlled descent of 100mm per second (approx.) is an inbuilt safety feature. In the event of power failure, manual override is achieved by pulling a pull cord to close the shutter under controlled descent and a hand chain to open. The handchain override is designed for emergency use only. As standard each shutter will include an open/stop/close push button station mounted on the motor side at approximately 1500mm above the finished floor allowing sight of the shutter during normal operation. Other control options available are shown under Options. All switchgear unless otherwise stated are surface mounted. Modes of Activation Option 1 Self closing by means of a thermal fusible link activated at a temperature of 68 C and mounted to the underside of the hood Option2 *24v DC auto resetting solenoid release device connected to the fire alarm/smoke detector. Solenoid automatically resets when the shutter is fully opened by pressing the up button and when the alarm has been turned off. (On hand chain operated shutters the solenoid is reset manually by pulling on a cable). Syston Doors do NOT include for connecting into the fire alarm. Option 3 All as Option 2 but with mechanical fusible link back up. Size Parameters Chain operated 4000 x 4000mm Power operated 7000 x 7000mm Larger sizes available on application. Finish All components other than curtain, bottom rail & hood finished primed. Curtain, bottom rail & hood (& motor cover if fitted) are galvanised. Powder coated finish to BS/RAL colours available at extra cost. Options Shutter Closing audio-visual warning panel with in-built time delay to one or both sides of shutter. Battery back up for solenoid release device. Fuse link back up for shutter fitted with solenoid release device. Key switch control. Galvanised sheet steel fascia. Motor cover (usually included if under 2500mm high). Part close facility using audio visual warning panel. (Shutter to act as smoke curtain with full closure after pre-set delay. Shutter MUST have a maintained power supply to accommodate this function). The fire alarm circuit must provide the supply for the solenoid (0.5 amps) with an initial supply of 3.5 amps for m/seconds to release the shutter but only when in the alarm condition. (If the fire alarm circuit is unable to provide a 24v DC supply for the solenoid or ancillaries a battery back-up system can be provided at extra cost). Note! To comply with current legislation fire shutters cannot be linked to fire alarm systems if they are over fire exits or cover a fire exit route. They can only be fitted with a device, which will close the shutter, by a local heat source i.e. fusible link. 7 Flame Shield audio visual warning panel
8 Technical Information Flame Shield 240 Face Fitted Fit Within Minimum fixing face if fitted to steel is 75mm Sideroom requirements A B 3000 x x x Headroom requirements X Y 3000 x x x Full width access to be maintained for future service and maintenance. Minimum width available is 800mm overall end plates. Arrangement Maximum size (mm) W x H 1 Hour 2 Hour 4 Hour Hand Chain/Electric 4000 x 2500 Electric 3000 x 5000 Roller Support Bracket Electric 4000 x Electric 5000 x Electric 6000 x Electric 6000 x Electric 7000 x Door Weight Varies with opening size dependant on lath/barrel/casing requirements but typically 45 kg/m 2 approximately. 8
9 Technical Information Further technical information is given on our website... Self-Coiling Fire Shutter Application Designed for smaller openings the Syston Doors self-coiling fire rolling shutter has been tested by the Loss Prevention Council (Report No.TE6697) and assesed by the BRE, Certificate CC10571, and can be face fixed or fitted within the opening. Operating via a counterbalanced sprung roller, the shutter will close automatically by fusible link at 68 C closing by means of a weight bar under gravity. We can also offer an automatic release system (solenoid) to allow the shutter to close on an alarm signal. The fire alarm must provide the supply for the solenoid (90m/amps). Syston Doors do not include for connecting into the fire alarm. *Maximum size: 1800mm clear width x 2100mm clear height. General Specification Curtain Shutter curtains are constructed from 50mm flat faced laths with a standard Tee bottom rail. Hood (Coil Casing) A galvanised sheet steel hood is included as standard. A fascia can be included if required at extra cost. Guides Vertical guides are fabricated from 50mm deep galvanised steel channels. Locking Standard locking is by bottom rail mounted shootbolts. Cylinder key operated locks are available at extra cost. Finish Standard finish is, curtain, bottom rail, guides & hood/fascia galvanised. Powder coated finish to a standard range of BS/RAL colours available at extra cost *N.B. The maximum clear opening height available with a push up fire rolling shutter is 2100mm. Above this size an electrically operated shutter must be used. Manual shutters can be used for normal security but will be heavier to lift than non fire rated shutters. This should be considered if doors are used regularly. For controlled descent and ease of use we recommend electrically operated fire shutters. 9 HEIGHT Y Z F ALL DIMENSIONS IN MILLIMETRES WEIGHT 30kg/m 2
10 Fireflex R Radiant Heat Reducing Fire Resisting Rolling Shutter Application Tested by the Loss Prevention Council (Test Report ) to an integrity of 240 minutes (4 hours) for openings up to 50 m 2 Fireflex is an obvious choice where increased risk of fire is a major concern. Fireflex provides a substantial safety barrier between the source of the fire and any precious or dangerously flammable stock. Fireflex is the perfect application for hospitals, shopping centres and industry. Designed for internal or external applications where increased fire protection is required. It provides radiant heat protection with reliable operation through a simple control panel that can be adapted for a range of activation methods. Fireflex is power operated with controlled descent following automatic activation. A safety brake is included as standard at the non motor end. Due to its unique construction, the radiant heat levels around Fireflex drop from 65kw m 2 to 2.7 kw m 2. This means that combustible materials can be stored 500mm away from a 1200 o C inferno, increasing floor space and reducing risk and break down of fire compartmentation. Fireflex R also has a weighted sound reduction of 18 db (BS5821 Part 3: 1984). General Specification Curtain Manufactured from pre galvanised material designed to provide a hollow section panel with ceramic infill. Each section is 100mm high with twin ribbed face for rigidity. The curtain is held in position with purposely designed end fittings which act as a curtain alignment system. The bottom panel is terminated with a galvanised steel plate with horizontal and vertical slots. Hood (Coil Casing) All Fireflex R shutters include a galvanised sheet hood as standard with optional motor cover. (Motor cover always included if less than 2500mm high). Guides Formed from pre galvanised steel. Endplates Mild steel of appropriate thickness relative to door size. Finish Standard finish to all parts is galvanised. Powder coated finish to a standard range of BS/RAL colours available at extra cost 10
11 Operation Fireflex Shutters are power operated by a 3 phase & neutral motor with various options of release: Level 1 Fusible Link Operation Normal operation by push button station or keyswitch with fuse link to close shutter at local heat source of 75 o C. *Level 2 Alarm activation with manual reset Normal operation by push button station or keyswitch with solenoid release to close shutter following fire alarm signal with manual reset of solenoid by pull cables. *Level 3 Alarm activation with automatic reset Normal operation by push button station or keyswitch with solenoid release to close shutter following fire alarm signal with automatic reset of solenoid once alarm is switched off by fully opening shutter. *Level 4 Alarm activation with automatic reset and part close facility Normal operation by push button station or keyswitch with solenoid release to close shutter following fire alarm signal with automatic reset of solenoid once alarm is switched off by fully opening shutter. Shutter can also part close to act as a smoke curtain, fully closing after an adjustable delay. Shutter must have maintained supply for this function. *For Level 2, 3 and 4 Audible Visual (with adjustable delay timer) can be included to one or both sides of the opening. Fire Alarm requirements The Fire Alarm circuit must provide the supply for the 24v DC solenoid (0.5 amps) with an initial supply of 3.5 amps for m/seconds to release the shutter but only when in the alarm condition. If the fire alarm is unable to provide a 24v DC supply a battery back up system is available at extra cost. The 24v DC supply needs to be provided separately from that of the fire alarm system as under the requirements of BS5839 Clause 19, the connection of such equipment is specifically prohibited. Syston Doors DO NOT include for connecting into the fire alarm circuit. Note! To comply with current legislation fire shutters cannot be linked to fire alarm systems if they are over fire exits or are on a fire exit route. They can only be fitted with a device, which will close the shutter, by a local heat source i.e. fusible link. Fireflex audio visual warning device 11
12 Technical Information Fireflex R Elevation Plan Width Height A B C With hood support over 3000mm wide Distance from the opening Single Shutter Double Shutter 500mm Fireflex Distance between structure in metres Radaint heat profile showning the safe distance storage of combustable materials for a 7m x7m opening. Irradiance - kw sq m 70 SINGLE SKINNED ROLLER SHUTTER 65 kw sq m FIREFLEX 3.5 kw sq m Time - Minutes Irradiance recorded 3 metres from centre of unexposed face 12
13 Syston Doors is a leading manufacturer and supplier of industrial doors, rolling shutters and associated products and has developed a comprehensive range to meet the requirements of the specifier, designer and end user. Established since 1920 and with a wealth of experience, Syston Doors is based in Syston, near Leicester at the heart of the motorway network, offering nationwide service. Our range includes: Rolling Shutters & Grilles in Steel, Aluminium and Timber Fire Resisting Rolling Shutters Rapid Action Doors Steel Doorsets Folding Shutter Doors Dock Shelters, Seals & Dock Levellers Insulated Rolling Shutters Insulated Sectional Doors Transparent Rolling Door Systems Sliding Folding Closures PVC Strip Curtains & Rubber Crash Doors Collapsible Grilles for Windows & Doorways Window Rolling Shutters Moveable Walls & Concertina Screens Domestic Garage Doors & Rolling Shutters Retractable Awnings & Shading Systems Nationwide Repair & Service to all makes & types of Industrial Door Albert Street, Syston, Leicester LE7 2JB, U.K. Telephone: (0116) Fax: (0116) [email protected] or visit We reserve the right to change or modify specification without alteration to this leaflet. Pictures shown for illustration purposes only. October 2006 E.&O.E. Please note, this brochure does not form part of any contract.
Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter
Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter C38 Vision 38 showing in-line punching Continental Range Experience Syston Doors have been manufacturing & supplying
FIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
MODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HSR-007
CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI
CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI The Company Founded in 1973 by Mr Imes Tinti in association with his son Vanni Tinti. In 1999 the locksmith workshop became a modern industrial company
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market
LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market Ian Stewart Passive installer scheme manager September 2011 Introduction to BRE Global Research,
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Loss Prevention Standard
Loss Prevention Standard : ISSUE 3.0 Requirements for the LPCB Approval and Listing of Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire Barriers This standard
STANDARD FOR NON-FIRE RATED ROLLING DOORS
ANSI/DASMA 203-2004 AMERICAN NATIONAL STANDARD STANDARD FOR NON-FIRE RATED ROLLING DOORS Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851
V1504 Vertical Platform Lift OWNER S MANUAL
V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 03-m12-2013 2 IMPORTANT Ensure that only an authorized Savaria Dealer
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
Architectural Specifications* MODEL HDE
MODEL HDE 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] TNR Model HDE Tech Specs September 4, 2012 Page
V1504 Vertical Platform Lift OWNER S MANUAL
V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 01-m03-2016 2 IMPORTANT Ensure that only an authorized Savaria Dealer
Relevant British, European and International standards
Relevant British, European and International standards BS 1245:1975 Specification for metal door frames (steel) BS 3621:2007 + A1:2009 Thief resistant lock assemblies - Key egress BS 476-20:1987 Fire tests
DESIGN CLARIFICATION (DC)
DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title:
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE
Multilift PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: ASME A17.1 ASME A18.1 CSA B613 CSA B355-09 19-m01-2015 Part No. 000790 Copyright 2015 Savaria Corporation All rights reserved. Printed
ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
Fire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE
Multilift (B613) VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: CSA B613 01-m06-2011 Part No. 000790 Copyright 2011 Savaria Corporation All rights reserved. Printed in Canada Purpose of this guide
SHUTTER INSTALLATION INSTRUCTIONS. AUGUST 2006 Version 2
SHUTTER INSTALLATION INSTRUCTIONS AUGUST 2006 Version 2 All rights reserved; no part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic,
Approved Document Q: Security
Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of
High-speed folding doors. F Series
High-speed folding doors F Series 02 F Series The horizontal folding motion of high-speed folding doors ensures that the entire vertical clearance is achieved immediately. F Series doors open at high speed
- 5 - Table1. Maximum Compartment Volumes
- 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,
Manual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
Architectural Specifications MODEL HDXL 9. 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8
MODEL HDXL 9 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HDXL 9 Tech Specs September 4, 2012
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
Belt Conveyor System
Belt Driven Conveyors the cost effective solution for transporting unit loads. Systems Handling Services range of powered belt conveyors is designed for applications where improved load control and speed
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors
ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended
Product Data Sheets. Belt Conveyor System
Product Data Sheets Belt Conveyor System Belt Conveyor System Belt Driven Conveyors the cost effective solution for transporting unit loads. Texam Limited s range of powered belt conveyors is designed
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Building Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
Office of the State Fire Marshal. Fire Rated Doors
Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow
Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.
SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
DIAMOND Retractable Rodding Robot Model SPRAYROD-R
2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic
Code of Practice for fire resisting metal doorsets
COP 1005 Code of Practice for fire resisting metal doorsets Scope The aim of this document is to provide guidance on the best practice for, and a better understanding of, hinged or pivoted fire resisting
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
Fire precautions in dwellings. Private sector housing Providing homes building communities
Fire precautions in dwellings Private sector housing Providing homes building communities Version 3 Published by Norwich City Council August 2011 Contents Page Introduction 1 2 Types of dwellings (A) Shared
TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER
Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Technical data sheet PVC Bi-fold doors
Standard Specifications White internally beaded, Deceuninck 3000 series profile 28mm Low-e toughened sealed units with argon gas Open in doors with white handles and hinges Tracks are fitted to the top
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
PHA 2000 PHB 3000 EXIT PAD
PHA 2000 PHB 000 EXIT PAD Panic Hardware in Contur Design PHA 2000 PHB 000 EXIT PAD THE MODULAR PANIC HARDWARE-SSTEM IN CONTUR DESIGN Prior knowledge of how to open the escape door is not expected. DANGER
Glass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
Services Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
SELF OR MANUALLY CLOSING FLOOD BARRIER PRODUCT INFORMATION
SELF OR MANUALLY CLOSING FLOOD BARRIER PRODUCT INFORMATION MODEL: HINGED FLOODGATE SELF OR MANUALLY CLOSING FLOOD BARRIER PRODUCT INFORMATION TABLE OF CONTENTS: Page General Principles of Operation 3 System
Tel: 0800 975 4933 Sales: [email protected] STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK
Tel: 0800 975 4933 Sales: [email protected] STORAGE PREMIERSHIELD anti-bacterial powder coating system quality products made in the UK MEDIUM DUTY : 88 SERIES PREMIER BDU DESK UNITS: 88 SERIES Of welded
FIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Flash Butt Welding Machines
Flash Butt Welding Machines Types AS 15 - AS 320 Flash butt welding current brake current (ka) current time flattening reversal preheating welding time flash butting forging A reliable and economic process
SECTION 08330. FireGard ROLLING FIRE DOORS / SMOKESHIELD FIRE DOORS
SECTION 08330 FireGard ROLLING FIRE DOS / SMOKESHIELD FIRE DOS GENERAL NOTES TO SPECIFIER: THIS SPECIFICATION SECTION HAS BEEN PREPARED TO ASSIST DESIGN PROFESSIONALS IN THE PREPARATION OF PROJECT OFFICE
Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments
Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data
Installation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:
RADAR. 227 www.ncdirect.co.uk
RADAR solutions RADAR RADAR Key System 228 RADAR Lockset 229 RADAR Cover Plate 229 RADAR Padlock 230 RADAR Automatic Toilet Entry System 231 RADAR Ramp 231 RADAR Ramp Sign 231 227 www.ncdirect.co.uk RADAR
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa
Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard
garage door operators
garage door operators duo vision separate control unit with integrated interior pushbutton Optional designer control housings other control unit housings with different finishes (ask about further designs)
Guidance on loft conversions in two-storey houses
Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for
Fire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
Awning Instructions. Full Cassette 1.5m to 6m
Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -
Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors
MORE CONVENIENCE FOR YOUR HOME Quality Operators for Garage Doors and Entrance Gates Garage door operator LIFTRONIC for up-and-over doors and sectional doors Entrance gate operator PORTRONIC for hinged
Morgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.
BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values
Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values SFB 1074 is available in two versions. In the first version the profiles are insulated with 30 mm glass fibre reinforced
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
TELESCOPE Motorized Lighting Suspension
TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend
Vario Roof. Model R171. 287 HO 04 Vario Roof (CrullG) 08-17-04
Vario Roof Model R171 287 HO 04 Vario Roof (CrullG) 08-17-04 1 Objectives At the end of this session, you will be able to: 1. Explain how roof can be operated 2. Explain operation of front and rear windows
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
NRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.
Breezway Altair Powerlouvre Window 35 Breezway Altair Powerlouvre Window The Powerlourve Window motor is neatly concealed within the Easyscreen TM Frame or the Component Powerlouvre Head Section. Automated
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
08 33 00/CHI BUYLINE 4676. Rolling Steel. Buyer s Guide THE DOOR TO QUALITY.
C O M M E R C I A L R O L L I N G S T E E L D O O R S 08 33 00/CHI BUYLINE 4676 Rolling Steel Buyer s Guide THE DOOR TO QUALITY. CONTENTS for Commercial Rolling Steel Doors 4... 6000 NON-INSULATED SERVICE
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
The replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
Dubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
Safety Storage Cabinets
Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased
Sliding and Folding Door Fittings Sliding Door Accessories
Sliding door lock Toplock For 1- and 2-leaf sliding doors Suitable for toughened safty glass and laminated sheet glass Suitable for DIN left and DIN right Max. weight per door leaf 120 kg For glass thickness:
FIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!
Secure and efficient IT room solutions Composite Panel Systems Compared Panel Systems are not all the same! When it comes to accommodating critical IT systems, the first issue to look at is the environment
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes!
DEMOUNTABLE CONTAINERS & WAREHOUSES Construct the Quick-Build Container in under 5 minutes! Quick-Build Warehouse, assembly in just a few hours... Quick & Easy! Available to order NOW! build in 15 mins!