WIRING PIPES AND ACCESSORIES

Size: px
Start display at page:

Download "WIRING PIPES AND ACCESSORIES"

Transcription

1 WIRING PIPES AND ACCESSORIES

2 2 WIRING PIPES Wiring s and accessories The s and accessories are made in compliance with ČSN EN ed. 2, specifications and approved documentation. The PVC s and accessories passed the test of resistance against spread of flame in compliance with ČSN EN ed. 2. According to ČSN 212 ed. 2, its use is possible in materials with fire reaction class A1 - F in accordance with ČSN EN Polyethylene s of type LPE 1 and LPE 2 with low and very low mechanical resistance can be used only for installing on/into class A1 non-inflammable materials. The s are intended for installation to the distribution of low voltage. Manufacturer reccommends the assembling of plastic s at the temperature over 0 C. The ČSN standard is applicable for storage. It is possible to install flexible and tough necked s with accessories on premises where there is danger of explosions of flammable gases and vapours (zone 2) or danger of explosions of flammable dust (zone 22); the wiring must be performed according to ČSN EN Flexible s Rigid socket s Cable protection KOPOFLEX and KOPODUR Sectional protection KOPOHALF Earthen channel KOPOKAN Optical cable protectors - HDPE Steel s Aluminium s Flexible metal Drainage KOPODREN Tube length tolerance - rigid: ± 10 mm Protective tube length tolerance - KOPOFLEX: ± 0,5 m - flexible: ± 1 % - KOPODUR: ± 1 % - HDPE: ± 2 mm/m - KOPOHALF ± 10 mm - KOPOKAN ± 10 mm Icons - legend material color temperature resistance, scope of application ( C) thread fire reaction class of underlying material wall thickness self-snuffing minimum bending radius (mm) P mechanical resistance / load limit value (N) limit of compression strength (kpa) sheet metal thickness mechanical protection classification code according to ČSN EN package (m; pcs) classification code according to ČSN EN accessories, additional assortment area with a risk of explosion dn outside diameter level of protection - IP classification di minimal inner diameter functionality during a fire R bending radius halogen-free material L length UV stable

3 WIRING PIPES Classification codes for the declared properties of the piping system according to ČSN EN edition 2 The code classifies the conduits and their accessories according to compressive strength, impact strength, minimum and maximum admissible installation temperature. first digit second digit third digit fourth digit fifth digit compressive strength impact strength Pipes: KOPOS TYP 1516E EN 2241 (20 N) PVC KOPOS TYP 4016E EN 41 (750 N) PVC KOPOS TYP 8016E EN 4441 (1250 N) PVC lowest admissible temperature highest admissible temperature resistance to bending 1 very low 125 N 1 very low 0,5 J C C 1 lead 2 low 20 N 2 low 1 J 2-5 C C 2 flexible medium 750 N medium 2 J - 15 C +105 C flexible/elastic 4 high 1250 N 4 high 6 J 4-25 C C 4 flexible 5 very high 4000 N 5 very high 20,4 J 5-45 C C C C Classification codes for the declared properties of the fixing equipment according to ČSN EN Classification codes for the declared properties of the piping system fixing equipment. first digit second digit third digit fourth digit fifth digit sixth digit seventh digit resistance to lateral load impact resistance range of low temperatures range of high temperatures corrosion resistance flame spread resistance resistance to axial load 2 low lateral load medium lateral load 4 high lateral load 1 very low impact strength 2 low impact strength medium impact strength 4 high impact strength 5 very high impact strength 1 +5 C 2-5 C -15 C 4-25 C 5-45 C C C C +105 C C C C C 1 low protection inside and outside 2 medium protection inside and outside medium protection inside, high protection outside 4 high protection inside and outside 1 flame retardant 2 spreading flame 0 not specified 1 specified by the producer All s and accessories (except for Weicon) are in compliance with EU directives. Flexible s of types 14.. and 12.. and rigid s of types 15.., 40.., 80.., 15.. HF, 40.. HF including elbows and couplings are in compliance with German electrical Standard.

4 4 WIRING PIPES LPFLEX - very low mechanical resistance PVC C A1 - F 0 sec. 125 N/5 cm For installation into or under the parget. Suitable for mounting into plaster walls and ceilings. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). EN ČSN description 216E H100 - dn di min. L mm mm m m pg H100D with wire 100 min ,7 H H50D with wire 50 min H H100D with wire 100 min H ,1 25 min H50 - grey-white H50D with wire 50 min H , H50D with wire 50 min H , H50D with wire 50 min H , H , H ,7 1,5 H H ,2 16,0 H grey-white H ,5 22,9 H H50-4,5 28, H50-42,2 5, material fire reaction class of underlying material mechanical resistance area with a risk of explosion package temperature resistance self-snuffing classification code according to color accessories

5 WIRING PIPES 5 MONOFLEX - low mechanical resistance PVC C A1 - F 0 sec. 20 N/5 cm For surface installation, into or under parget. Suitable for mounting into hollow walls, plaster walls and ceilings. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). EN ČSN description 1416E /1 K100 - F50 - dn di min. L mm mm m m pg H50 - white K ,7 K light grey K K50D with wire F H50 - white K K , K25 - light grey K K50D with wire F H50 - white K K , K25 - light grey 25 min K K50D with wire F H50 - white K , K light grey K25D with wire K F H25 - white ,2 K light grey K25D with wire F25-25 min ,6 K25 - light grey ,7 1, /1 K100-21,2 16, /1 K100 - light grey 28,5 22, /1 K50-4,5 28, /1 K50-42,2 5, material fire reaction class of underlying material mechanical resistance area with a risk of explosion package temperature resistance self-snuffing classification code according to color accessories

6 6 WIRING PIPES SUPER MONOFLEX - medium mechanical resistance PVC C A1 - F 0 sec. 750 N/5 cm 212 For surface installation, into or under parget. Suitable for mounting into hollow walls, plaster walls and ceilings. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). EN description 1216E di dn L min. mm mm m m pg. L ,7 L50D with wire L L100D with wire ,1 L L50D with wire L50 - dark grey , L50D with wire L , L25D with wire L ,2 L25D with wire L , Clamps for flexible s ČSN PVC C A1 - F 0 sec The clamps are equipped with fastening elements for placing next to each other to create continual row thereof as well as with grooves for installation in supporting trunkings of 5820/..series (see pg. 2-65). To install, push the between the clamp jaws. ČSN di H mm mm pcs 51 LB 19,4 0 10; LB 21,5 2 10; grey 521 LB 27, 7 10; LB 5, ; material fire reaction class of underlying material mechanical resistance classification code according to color accessories temperature resistance self-snuffing classification code according to area with a risk of explosion package

7 WIRING PIPES 7 MONOFLEX PP - low mechanical resistance PP C A1 - F 0 sec. 20 N/5 cm 2222 For surface installation, into or under parget. Suitable for mounting into hollow walls, plaster walls and ceilings. Flexible self-extinguishing made from PP with low content of halogen elements. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). EN description 1416EPP 1420PP 1425PP dn di min. L mm mm m m pg. F ,7 F100D with wire F ,1 F100D with wire F ,2 F50D with wire PP F ,2 F50D with wire PP F , PP F , SUPER MONOFLEX HFPP - medium mechanical resistance PP C A1 - F 0 sec. 750 N/5 cm 42 Flexible halogen-free self-extinguishing made from PP. For installation on the surface, in plaster, under plaster or into concrete. Suitable for mounting into hollow walls, plaster walls and ceilings. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). Halogen-free s are used on premises where the safety of people and property is primary, e.g.: public buildings, hospitals, schools, theatres, airport halls, shopping centres, etc. EN description dn di min. L mm mm m m pg. 1216EHFPP L100 - grey 16 10, HFPP 1225HFPP 122HFPP 1240HFPP 1250HFPP K light grey K100D with wire 20 14, L L100 - grey ,2 L100D with wire K light grey K50D with wire 2 24, L L ,4 L50 - grey L ,2 L material fire reaction class of underlying material mechanical resistance area with a risk of explosion color accessories temperature resistance self-snuffing classification code according to halogen-free material package

8 8 WIRING PIPES APAFS, APACS - low mechanical resistance PA stable mounting: C A1 - F 0 sec. 20 N/5 cm flexible mounting: C * Flexible UV stable halogenless self-extinguishing made from PA 6. Halogen-free s are used on premises where the safety of people and property is primary, e.g.: public buildings, hospitals, schools, theatres, airport halls, shopping centres, etc. * electrical properties - undeclared EN dn di min. L mm mm m APAFS16 F50 15,8 11, APAFS21 F50 21,2 16, APAFS28 F50 28,5 22, APAFS4 F50 4,5 28, APACS42 F25 42,5 5, APACS54 F25 54,5 46, APACS80 F10 79, 67, Accessories for flexible s APAFS / APACS Adaptalok is a system of utilities allowing to terminate and fix the. Utilities allow 45 and 90 tapping and direct threaded termination - M16 - M50 or PG1,5 - PG48. The termination is available as for flange as well. Installation and removal is easy and quick. Utilities are equipped with removal part allowing to remove the termination easily and without breaking. Adaptalok is tested in compliance with ČSN EN There is possible to assemble it into the space of dangerous area 2 at the environment of hazard explosion and inflammable gases and vapors. Sales from 1 pc. Combination of utilities is driven by outside diameter of used. PA stable mounting: C 0 sec. IP66 flexible mounting: C Adaptalok direct flange Adaptalok 90 flange Adaptalok 45 flange Adaptalok termination dn mm 16 A16FL A16FL A16FL A-ES A-ES A21FL A21FL A21FL A28FL A28FL A28FL A-ES A-ES A-ES A80FL material fire reaction class of underlying material mechanical resistance IP protection UV stable accessories temperature resistance self-snuffing area with a risk of explosion halogen-free material color

9 WIRING PIPES 9 EN Adaptalok direct Adaptalok 90 Adaptalok 45 dn mm 16 M16x1,5 AM16/ AM16/ AM16/ M20x1,5 AM20/ M20x1,5 AM21/ AM21/ AM21/ M25x1,5 AM25/ M25x1,5 AM28/ AM28/ AM28/ M2x1,5 AM4/ AM4/ AM4/ M40x1,5 AM42/ AM42/ AM42/ M50x1,5 AM54/ AM54/ AM54/ ČSN 16 PG1,5 APG16/ APG16/ APG16/ PG16 APG21/ APG21/ APG21/ PG21 APG28/ APG28/ APG28/ PG29 APG4/ APG4/ APG4/ PG6 APG42/ APG42/ APG42/ PG48 APG54/ APG54/ APG54/ EN Adaptalok washer Adaptalok nut Dismounting part dn mm 16 M16x1,5 A-SW/M A16RT M20x1,5 A-SW/M A21RT M25x1,5 A-SW/M The nut is a part of the AM adapt-lock A28RT M2x1,5 A-SW/M package... A4RT M40x1,5 A-SW/M A42RT M50x1,5 A-SW/M A54RT ČSN 16 PG1,5 A-SW/PG A-LN/PG A16RT PG16 A-SW/PG A-LN/PG A21RT PG21 A-SW/PG A-LN/PG A28RT PG29 A-SW/PG A-LN/PG A4RT PG6 A-SW/PG A-LN/PG A42RT PG48 A-SW/PG A-LN/PG A54RT halogen-free material thread UV stable

10 10 WIRING PIPES LPE-1 - low mechanical resistance PE C A1 20 N/5 cm 2242 Suitable for direct monolithic concreting or under the parget. EN ČSN description dn di min. L mm mm m m pg. 216E/LPE-1 A ,7 A100D with wire 100 min /LPE-1 A ,1 A100D with wire 100 min A orange - 225/LPE-1 A100D with wire 25 18, A50-50 min /LPE-1 A , A50D with wire /LPE-1 A , /LPE-1 H100-21,2 16, /LPE-1 H100 - white 28,5 22, /LPE-1 H50-4,5 28, material temperature resistance classification code according to color accessories fire reaction class of underlying material mechanical resistance halogen-free material package

11 WIRING PIPES 11 LPE-2 - very low mechanical resistance PE C A1 125 N/5 cm 1142 Suitable for installing into prefabricated concrete elements. EN ČSN description dn di min. L mm mm m m pg. 216E/LPE-2 A orange A100D with wire 100 min ,7 F min F100D with wire 100 min /LPE-2 A orange A100D with wire 100 min ,1 F min F100D with wire 100 min /LPE-2 A orange - A100D with wire , -21 F min F100D with wire 100 min /LPE-2 A orange A50D with wire 50 min , F50-50 min F50D with wire 50 min /LPE-2 A25 - orange ,2 F25-25 min A100 - orange /LPE-2 F100-18,7 1,5 100 min H100 - white /LPE-2 22/LPE-2 A100 - orange 100 min F100-21,2 16,0 100 min H100 - white A100 - orange 100 min F100-28,5 22,9 100 min H100 - white A50 - orange 50 min /LPE-2 H50 - white 4,5 28, F50-50 min /LPE-2 H50 - white 42,2 5, material temperature resistance classification code according to color accessories fire reaction class of underlying material mechanical resistance halogen-free material package

12 12 WIRING PIPES LPE-1 - UV stable, low mechanical resistance PE C A1 20 N/5 cm 2242 Flexible UV stable to be suitable for outside installations. EN description 220/LPE-1 225/LPE-1 22/LPE-1 dn di min. L mm mm m m pg. F1.DU with wire ,1 F1.U F1.DU with wire , F1.U F50DU with wire , F50U LPE-2 - UV stable, very low mechanical resistance PE C A1 125 N/5 cm 1142 Flexible UV stable to be suitable for outside installations. EN description 220/LPE-2 225/LPE-2 22/LPE-2 dn di min. L mm mm m m pg. F1.DU with wire ,1 F1.U F1.DU with wire 100 min , F1.U F50DU with wire , F50U material fire reaction class of underlying material classification code according to UV stable package temperature resistance mechanical resistance halogen-free material color accessories

13 WIRING PIPES 1 SPIROFLEX - low mechanical resistance PVC C A1 - F 0 sec. 20 N/5 cm 2114 Flexible protective reinforced with hard PVC spiral. Excels in smooth inside surface and very good strength, while the flexibility is guaranteed. Suitable for systems with mechanical strain and constant pressure, e.g.: industrial systems and machine equipment. dn di min. L mm mm m m SF16 K0 20, SF20 K0 25, light grey SF25 K0 0, SF2 K0 8, Conduit bushing SPIROFLEX PVC C A1 - F 0 sec. IP64 For the type di of mm mm pcs SFM20 KB 16 SF16 M20x1, SFM25 KB 20 SF20 M25x1, light grey SFM2 KB 25 SF25 M2x1, SFM40 KB 2 SF2 M40x1, material fire reaction class of underlying material mechanical resistance IP protection package temperature resistance self-snuffing classification code according to color accessories

14 14 WIRING PIPES Rigid wiring s - low mechanical resistance PVC C A1 - F 0 sec. 20 N/5 cm IK06 Rigid socket s are fireproof-tested. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). EN 1516E dn di min. L mm mm m m pg. HA white 0; KA 16 1,7 0; light grey KC 2 20; HA white 0; KA 20 17,4 0; light grey KC 2 20; HA white 0; KA 25 22,1 0; light grey KC 2 20; HA white 0; KA 2 28,6 0; light grey KC 2 20; HA white 0; KA 40 6,6 0; light grey KC 2 20; HA white 0; KA 50 45,9 0; light grey KC 2 20; HA white 15; ,4 KA light grey 15; material fire reaction class of underlying material mechanical resistance area with a risk of explosion color accessories temperature resistance self-snuffing classification code according to mechanical protection package

15 WIRING PIPES 15 Rigid wiring s - medium mechanical resistance PVC C A1 - F 0 sec. 750 N/5 cm 411 IK07 Rigid socket s are fireproof-tested. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). Length of 2 m, until stocks are exhausted. EN 4016E dn di min. L mm mm m m pg. KA 0; light grey KC 2 20; ,0 LA 0; dark grey LC 2 20; KA 0; light grey KC 2 20; ,9 LA 0; dark grey LC 2 20; KA 0; light grey KC 2 20; ,4 LA 0; dark grey LC 2 20; KA 0; light grey KC 2 20; ,0 LA 0; dark grey LC 2 20; KA 0; light grey KC 2 20; ,8 LA 0; dark grey LC 2 20; KA 0; light grey KC 50 45,0 2 20; LA dark grey 0; KA 15; light grey KC 6 57,4 2 10; LA dark grey 15; material fire reaction class of underlying material mechanical resistance area with a risk of explosion color accessories temperature resistance self-snuffing classification code according to mechanical protection package

16 16 WIRING PIPES Rigid wiring s - high mechanical resistance PVC C A1 - F 0 sec N/5 cm IK09 Rigid socket s are fireproof-tested. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). Length of 2 m, until stocks are exhausted. EN 8016E dn di min. L mm mm m m pg. FA 0; ,2 FC 2 20; FA 0; ,8 FC 2 20; FA 0; ,6 FC 2 20; FA 0; ,0 FC 2 20; FA 0; ,0 FC 2 20; FA 50 44,1 0; FA 6 55,4 15; Elbows for EN s PVC C A1 - F 0 sec. IK09 The elbows with double-sided necks are intended for 90 bends. Bending radius ensures smooth transition and allows easy retraction of wires and cables. Rigid and flexible s can be connected using accessories for rigid. If a bend other than 90 is required, it is possible to replace the elbow with a flexible and connecting parts. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). R R dn dn mm mm pcs mm mm pcs 10; ; HB white 10; HB white 10; KB light grey 10; KB light grey 10; LB dark grey 10; LB dark grey 10; ; ; HB white 10; HB white 5; KB light grey 10; KB light grey 5; LB dark grey 10; LB dark grey 5; ; ; HB white 10; HB white 5; KB light grey 10; KB light grey 5; LB dark grey 10; LB dark grey 5; material fire reaction class of underlying material mechanical resistance area with a risk of explosion color accessories temperature resistance self-snuffing classification code according to mechanical protection package

17 WIRING PIPES 17 Connectors for EN s PVC C A1 - F 0 sec. IK09 Rigid and flexible s can be connected using accessories for rigid. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). L dn mm mm pcs 10; E HB white 10; KB light grey 10; LB dark grey 10; ; HB white 10; KB light grey 10; LB dark grey 10; ; HB white 10; KB light grey 10; LB dark grey 10; ; HB white 10; KB light grey 10; LB dark grey 10; ; HB white 10; KB light grey 10; LB dark grey 10; ; HB white 10; KB light grey 10; LB dark grey 10; ; HB white 2; KB light grey 2; LB dark grey 2; material fire reaction class of underlying material area with a risk of explosion color accessories temperature resistance self-snuffing mechanical protection package

18 18 WIRING PIPES Clamps for EN s PVC C A1 - F 0 sec IK09 The clamps are intended to fix the s to the underlying material. Pipes are installed by pushing between the clamp jaws. The clamps are equipped with elements for placing next to each other to create a continuous series of tubes, and also grooves for installation in supporting trunkings of 5820/.. (see page 2-65). The connection can be made for clamps of different sizes. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). A B dn mm mm mm pcs 10; E HB white 10; ,x6,5 12 KB light grey 10; LB dark grey 10; ; HB white 10; ,x6,5 12 KB light grey 10; LB dark grey 10; ; HB white 10; ,x6,5 12 KB light grey 10; LB dark grey 10; ; HB white 10; x10 14 KB light grey 10; LB dark grey 10; ; HB white 10; x10 14 KB light grey 10; LB dark grey 10; ; HB white 10; ,6x10,2 14 KB light grey 10; LB dark grey 10; ; HB white 10; ,6x10,2 14 KB light grey 10; LB dark grey 10; material fire reaction class of underlying material area with a risk of explosion mechanical protection package temperature resistance self-snuffing classification code according to color

19 WIRING PIPES 19 Halogen-free rigid wiring s - low mechanical resistance PC ABS C A1 - F 0 sec. 20 N/5 cm IK06 EN 1516EHF 1520HF 1525HF 152HF 1540HF 1550HF 156HF Halogen-free rigid necked suitable for distribution systems in apartments and industrial environments. Halogen-free s are used on premises where the safety of people and property is primary, e.g.: public buildings, hospitals, schools, theatres, airport halls, shopping centres, etc. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). The s are also available for systems maintaining functionality during a fire (see catalogue Systems maintaining functionality during a fire). The s are UV-stabilized. dn di min. L mm mm m m pg. FA 0; ,1 KA light grey 0; FA 0; ,1 KA light grey 0; FA 0; ,6 KA light grey 0; FA 0; ,4 KA light grey 0; FA 0; ,0 KA light grey 0; FA 0; ,6 KA light grey 0; FA 15; ,4 KA light grey 15; Halogen-free rigid wiring s - medium mechanical resistance PC ABS C A1 - F 0 sec. 750 N/5 cm 521 IK07 Halogen-free rigid necked suitable for distribution systems in apartments and industrial environments. Halogen-free s are used on premises where the safety of people and property is primary, e.g.: public buildings, hospitals, schools, theatres, airport halls, shopping centres, etc. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). The s are UV-stabilized. EN 4016EHF 4020HF 4025HF 402HF 4040HF 4050HF 406HF dn di min. L mm mm m m pg. FA 15; ,7 KA light grey 15; FA 15; ,7 KA light grey 15; FA 15; ,0 KA light grey 15; FA 15; ,0 KA light grey 15; FA 15; ,4 KA light grey 15; FA 15; ,2 KA light grey 15; FA 15; ,8 KA light grey 15; material self-snuffing area with a risk of explosion halogen-free material package temperature resistance mechanical resistance functionality during a fire UV stable accessories fire reaction class of underlying material classification code according to mechanical protection color

20 20 WIRING PIPES Halogen-free rigid wiring s - high mechanical resistance PC ABS C A1 - F 0 sec N/5 cm IK09 Halogen-free rigid necked suitable for distribution systems in apartments and industrial environments. Halogen-free s are used on premises where the safety of people and property is primary, e.g.: public buildings, hospitals, schools, theatres, airport halls, shopping centres, etc. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). The s are UV-stabilized. EN 8016EHF FA dn di min. L mm mm m m pg ,7 15; HF FA 20 15,7 15; HF FA 25 20,2 15; HF FA 2 27,0 15; HF FA 40 4,8 15; HF FA 50 44,2 15; HF FA 6 56,8 15; Elbows for halogen-free EN s PC ABS C A1 - F 0 sec. IK09 The elbows with double-sided necks are intended for 90 bends. Bending radius ensures smooth transition and allows easy retraction of wires and cables. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). The elbows are also available for systems maintaining functionality during a fire (see catalogue Systems maintaining functionality during a fire). Elbows in are UV stable. R dn mm mm pcs HF 10; KB light grey 10; HF 10; KB light grey 10; HF 10; KB light grey 10; HF 10; KB light grey 10; HF 5; KB light grey 5; HF 5; KB light grey 5; material self-snuffing area with a risk of explosion halogen-free material package temperature resistance mechanical resistance functionality during a fire UV stable accessories fire reaction class of underlying material classification code according to mechanical protection color

21 WIRING PIPES 21 Connectors for halogen-free EN s PC ABS C A1 - F 0 sec. IK09 Connectors are designed to join s. Socketing of s and elbows reduces the consumption of connectors when making rigid installations. It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). The couplings are also available for systems maintaining functionality during a fire (see catalogue Systems maintaining functionality during a fire). Connectors in are UV stable. L dn mm mm pcs HF 10; KB light grey 10; HF 10; KB light grey 10; HF 10; KB light grey 10; HF 10; KB light grey 10; HF 10; KB light grey 10; HF 10; KB light grey 10; HF 2; KB light grey 2; Clamps for halogen-free EN s PC ABS C A1 - F 0 sec IK09 The clamps are intended to fix the s to the underlying material. Pipes are installed by pushing between the clamp jaws. The clamps are equipped with elements for placing next to each other to create a continuous series of tubes, and also grooves for installation in supporting trunkings of 5820/.. (see page 2-65). It is possible to install on premises where there is danger of explosions of flammable gases and vapours (zone 2) and on premises where there is danger of explosions of flammable dust (zone 22). Clamps in are UV stable. A B dn mm mm mm pcs EHF 10; ,4x6,4 12,4 KB light grey 10; HF 10; ,4x8 12,4 KB light grey 10; HF 10; ,4x8 14 KB light grey 10; HF 10; ,4x10 14 KB light grey 10; HF 10; ,4x10 14 KB light grey 10; HF 10; ,6x10,2 14 KB light grey 10; HF 10; ,6x10,2 14 KB light grey 10; material self-snuffing area with a risk of explosion mechanical protection color temperature resistance mechanical resistance functionality during a fire halogen-free material package fire reaction class of underlying material classification code according to classification code according to UV stable accessories

22 22 WIRING PIPES KOPOFLEX - flexible doublecoat corrugated HDPE storage: C A1 450 N/20 cm montage: C IP40 Halogen-free flexible double-coated designed for mechanical protection of all kinds of power and data wiring. The s are made in compliance with ČSN EN Each coil is equipped with a pull-through string or wire that ensures easy cable insertion and a coupling on one end. When using a sealing ring, the protection class is IP 67. In case of mechanical compaction of layers above the protector, take care not to exceed the value of the load capacity of the protector - see catalogue PIPE PROTECTORS. dn di L in stock mm mm mm m m cm pg. AA orange min. 000 m KF KF KF 0906 KF KF KF BA red 65 x 0 BB CA blue CB x DA green min. 000 m EA yellow x 0 - min. 000 m FA AA orange min m BA red 80 x 5 BB CA blue CB x DA green min m EA yellow x 5 - min m FA AA orange min m BA red x CA blue DA green min m EA yellow x 5 - min m FA BA red x 40 CA blue CB x DA green min m EA yellow x FA AA orange min m BA red x 45 CA blue FA AA orange min m x 65 BA red BB x CA x blue CB x DA green min m EA yellow x 65 - min m FA KF BA red x BA x red BB x KF CA x blue CB x FA x BB red KF x material fire reaction class of underlying material IP protection color package to order, delivery time weeks temperature resistance mechanical resistance halogen-free material bending radius standard accessories

23 WIRING PIPES 2 KOPOFLEX - UV-stabilized flexible doublecoat corrugated HDPE storage: C A1 450 N/20 cm montage: C IP40 Halogen-free UV stable flexible double-coated designed for mechanical protection of all kinds of power and data wiring. The s are made in compliance with ČSN EN Each coil is equipped with a pull-through string or wire that ensures easy cable insertion and a coupling on one end. When using a sealing ring, the protection class is IP 67. In case of mechanical compaction of layers above the protector, take care not to exceed the value of the load capacity of the protector - see catalogue PIPE PROTECTORS. KF KF KF 0906 KF KF KF KF dn di L in stock mm mm mm m m cm pg. UVBA red min m UVCA blue x 0 - min m UVFA UVBA red min m UVCA blue x 5 - min m UVFA UVBA red min m UVCA blue x 5 - min m UVFA UVBA red min m UVCA blue x 40 - min m UVFA UVBA red min m UVCA blue x 45 - min m UVFA UVBA red min m UVCA blue x 65 - min m UVFA UVBA red min m UVCA blue x 80 - min m UVFA KOPOFLEX - halogen-free self-snuffing flexible double-coated HDPE storage: C A1 - F 0 sec. 450 N/20 cm IP40 montage: C Flexible double-coated self-snuffing designed for mechanical protection of all kinds of power and data wiring. Fire spread test according to ČSN EN dn di L in stock mm mm mm m cm KF SKA light grey x 65 - min m material self-snuffing halogen-free material bending radius package temperature resistance mechanical resistance UV stable standard accessories fire reaction class of underlying material IP protection color to order, delivery time weeks

24 24 WIRING PIPES KOPODUR - rigid doublecoat corrugated HDPE storage: C A1 450 N/20 cm montage: C IP40 Halogen-free rigid double-coated designed for mechanical protection of all kinds of power and data wiring. The s are made in compliance with ČSN EN The is available in form of a bar, the coupling is put on one end of it. The connection is sealed dust/sand resistant. When using a sealing ring, the protection class is IP 67. In case of mechanical compaction of layers above the protector, take care not to exceed the value of the load capacity of the protector - see catalogue PIPE PROTECTORS. dn di L in stock mm mm m m cm KD BC red x 45 x min m BC red min m KD CC blue x 66 x min m FC min m KD 0906 BC red x 52 x KD BC red x 88 x 607 CC blue BC red min m KD CC blue x 76 x min m FC min m BC red x 95 x KD CC blue x 64 x 610 FC min m BA min m red KD BC x 72 x min m CC blue min m BC red KD CC blue x 72 x FC KD BC red x 74 x Accessories for corrugated s KOPOFLEX and KOPODUR C Couplings - slip-over couplings are the same for both types of s and are used to join the s. Sealing rings - the same for both types of s and are used to seal the joint to prevent it against humidity and water. Closing plugs - for blinding of backup lines and for temporary blinding of s when installing. Distance spacers - for position fixation of several s in one excavation. Distance spacers are for fixation 8 s and spacer can be split for fixation 2, 4 and 6 s. Per order only. Couplings Sealing rings Closing plugs Distance spacers dn mm FA BB FA BB / FA BB / FA BB / FA BB / FA BB / BB / FA BB / BB / material fire reaction class of underlying material IP protection color standard temperature resistance mechanical resistance halogen-free material package to order, delivery time weeks

25 WIRING PIPES 25 KOPOHALF - divided cable duct HDPE storage: C A /2-450 N/20 cm montage: C 06160/2-750 N/20 cm IP0 A system of divided cable ducts is suitable mainly for a protection of underground cable laying and for a laying-out of the energy and communication lines. Another possible application is a protection of already installed underground cables. The protectors consist of two identical parts. When installing, the cables are put in the bottom part and then the top part is snapped to the bottom one. Connecting of protectors is performed by overlapping joined lower parts with an upper part at length of approximately 0 cm. The divided cable ducts are manufactured and tested in accordance with standard ČSN EN description dn di min. L mm mm m m BA in distributed position red BAD interlocked red /2 CA in distributed position blue CAD interlocked blue EA in distributed position yellow FA in distributed position BA in distributed position red BAD interlocked red /2 CA in distributed position blue CAD interlocked blue EA in distributed position yellow KOPOHALF - divided cable duct PVC storage: C A1 - F 0 sec. 750 N/20 cm IP0 montage: C A system of divided cable ducts is suitable mainly for a protection of underground cable laying and for a laying-out of the energy and communication lines. Another possible application is a protection of already installed underground cables. The protectors consist of two identical parts. When installing, the cables are put in the bottom part and then the top part is snapped to the bottom one. Connecting of protectors is performed by overlapping joined lower parts with an upper part at length of approximately 0 cm. The divided cable ducts are manufactured and tested in accordance with standard ČSN EN dn di min. L description mm mm m m BA in distributed position red BAD interlocked red P/ CA in distributed position blue CAD interlocked blue material fire reaction class of underlying material mechanical resistance halogen-free material package temperature resistance self-snuffing IP protection color

26 26 WIRING PIPES KOPOKAN - earthen channel PVC C A1 - F 0 sec. IP0 Earthen channels are intended for mechanical protection of installation of engineering networks to be loaded under ground. By its technical parameters those fully replace the earlier used concrete channels. There is possible to use them for additional protection already installed earthen engineering networks. Floor trunkings are supplied with a colour lid. Connected using connectors and folding the lid over, thus interconnecting the individual parts. Strength limit on compression tested on length 00 mm. Earthen channels are manufactured according to ČSN EN and ČSN EN A B L mm mm m m kpa KOPOKAN 1 CD grey body / blue lid ZD grey body / red lid KOPOKAN 2 ZD grey body / red lid KOPOKAN ZD grey body / red lid KOPOKAN 4 CD grey body / blue lid ZD grey body / red lid P connection for KOPOKAN PVC C A1 - F 0 sec. Connector is used to connect the ground channels. It provides a straight direction. description A B L mm mm m pcs SPOJKA K1 ZB for channel KOPOKAN ; SPOJKA K2 ZB for channel KOPOKAN ; SPOJKA K ZB for channel KOPOKAN ; SPOJKA K4 ZB for channel KOPOKAN ; material fire reaction class of underlying material IP protection package temperature resistance self-snuffing color P limit of compression strength

27 WIRING PIPES 27 Optical cable protectors HDPE HDPE C A1 750 N/20 cm description Single-coated s designed to protect optical cables. Cable protectors there is possible to deliver with inner wall to be lubrificated by mineral oil. For larger volumes different color versions (beyond presented versions), labeling, number of differential stripes, denticular inner surface or inner diameter size (material thickness) can be ordered based on customer needs and specifications. Shock resistance: N (normal, ČSN EN ) Bend resistance: flexible The protectors are tested under pressure of 1,5 MPa for the time of 1 hour. The packaging on wooden drums and pallets for unwinding drums is delivered just upon previous order according to the customers's specification. dn di L in stock mm mm m mm pg. FS100 - min. 000 m harness KS100 light grey - min. 000 m AB drum min. 000 m orange AS100 harness BB drum min. 000 m red BS100 harness CB drum blue min. 000 m / EB drum min. 000 m yellow ES100 harness min. 000 m drum min. 000 m FS100 harness LS100 harness dark grey AB drum min m AP harness - pallet min m orange AS harness AS min m BB drum min m BS100 red harness BS min m CB drum min m CP harness - pallet min m blue CS harness CS min m DB drum min m DS100 green min m harness 40 / 4 / DS min m EB drum min m ES100 yellow min m harness ES min m drum min m FP harness - pallet min m FS100 harness KB drum min m KS100 light grey harness KS min m LB drum min m LS100 dark grey min m harness LS min m AB drum min m orange AS100 harness min m BS100 harness red CB drum min m CP harness - pallet blue min m CS100 harness / min m drum min m FP harness - pallet min m FS100 harness KS100 harness light grey min m LS100 harness dark grey min m material fire reaction class of underlying material halogen-free material bending radius standard temperature resistance mechanical resistance color accessories to order, delivery time weeks

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Tubing and Accessories

Tubing and Accessories Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3

More information

Cable Management. Our Trunking Cutter provides Burr-Free cutting for Open-Slot Trunking. Maximum Width: Maximum Height:

Cable Management. Our Trunking Cutter provides Burr-Free cutting for Open-Slot Trunking. Maximum Width: Maximum Height: CABLE MANAGEMENT Inde Inde Iboco Standard Trunking Iboco Grey Trunking Iboco Blue Trunking Iboco Accessories Pages 6-7 Page 7 Page 6-7 Betaduct Trunking - Grey -3 Iboco TD & Blue Trunking 7 Betaduct Trunking

More information

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Cable entry plate KDP

Cable entry plate KDP Cable entry plate KDP Even faster and simpler assembly of pre-fabricated conduits. Die KDL/E replaces the tried-andtrue KDL/N model. The single-piece frame no longer needs to be joined together. The provided

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

3. Geberit Pluvia Roof Drainage Systems

3. Geberit Pluvia Roof Drainage Systems 3. Geberit Pluvia Roof Drainage Systems Assortment overview: Pluvia Outlets...52 3.1 Roof outlets... 53 3.1.1 Roof outlets up to 25 l/s...53 3.1.2 Roof outlets up to 100 l/s...55 3.2 Roof outlets for gutters...

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Transport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au. www.tubefit.com.

Transport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au. www.tubefit.com. Transport & Automotive CATALOGUE Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au March 2011 www.tubefit.com.au Page 1 4 6 9 12 14 16 17 19 20 22 23 24 26 28 29 31 33 Index

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

Hose and Tube Fittings Series 1-3

Hose and Tube Fittings Series 1-3 Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B, Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified

More information

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical

More information

Puddle Flange. FRANK Puddle Flange

Puddle Flange. FRANK Puddle Flange Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many

More information

NAYLOR. Metro Duct. The Complete Duct and Access System M E T R O D R A I N. The MANUFACTURING EXCELLENCE Awards Winner - Best SME

NAYLOR. Metro Duct. The Complete Duct and Access System M E T R O D R A I N. The MANUFACTURING EXCELLENCE Awards Winner - Best SME NAYLOR M E T R O D R A I N Metro Duct The Complete Duct and Access System e m a i l : s a l e s @ n a y l o r. c o. u k w e b : w w w. n a y l o r. c o. u k Winners Growing Business The MANUFACTURING EXCELLENCE

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System

KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System 2-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / E-LINE KX Compact Busbar Distribution System 63...63 A E-LINE KB Compact Busbar Distribution System 8...63 A E-LINE KO Plug-in

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Accessories. Fittings 2. Products assembly 4. Tube Spike 3/5 mm 8 T.N.L. 9. Vacuum Breaker 10. Line Flush Valve 11. Pressure Indicator 12

Accessories. Fittings 2. Products assembly 4. Tube Spike 3/5 mm 8 T.N.L. 9. Vacuum Breaker 10. Line Flush Valve 11. Pressure Indicator 12 Accessories For irrigation systems Version 1.0 Fittings 2 Products assembly 4 Tube Spike 3/5 mm 8 T.N.L. 9 Vacuum Breaker 10 Line Flush Valve 11 Pressure Indicator 12 Fittings Manifold 8 outlets To distribute

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

TECHNICAL DATASHEET Incremental Encoder RI 58-H Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock

More information

Model CS 64 Mini-DIN Cable and Adaptor

Model CS 64 Mini-DIN Cable and Adaptor Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink

More information

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Threaded Resistance Thermometers Model TR10-D, Miniature Design Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

THERMA-TUBE preinsulated pipes and fittings Catalogue of products

THERMA-TUBE preinsulated pipes and fittings Catalogue of products THERMA-TUBE preinsulated pipes and fittings Catalogue of products THERMA TUBE preinsulated pipes and fittings TABLE OF CONTENTS 1. GENERAL INFORMATION ABOUT THE USE OF PREINSULATED PIPES AND FITTINGS...

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

Horns. Buzzers 6.02-6.03, 6.06. Compressed air horns 6.09-6.10. Disc-type horns 6.05-6.06. Electric twin-tone horns 6.08

Horns. Buzzers 6.02-6.03, 6.06. Compressed air horns 6.09-6.10. Disc-type horns 6.05-6.06. Electric twin-tone horns 6.08 Buzzers 6.02-6.03, 6.06 Compressed air horns 6.09-6.10 Disc-type horns 6.05-6.06 Electric twin-tone horns 6.08 6.03-6.04 Supertone horns 6.07 6 EE 07 6.01 Part no. Pk. Buzzers With bracket, Two 6.3 mm

More information

GPD Rubber Press Seals

GPD Rubber Press Seals GPD Rubber Press Seals Leading in in ideas SYSTEM-TECHNIK GPD Rubber Press Seals Design Available with a rubber thickness of 30 mm for sealing against non-pressing water and a rubber thickness of 60 mm

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com

More information

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents

More information

CUSTOMER FLOW MANAGEMENT

CUSTOMER FLOW MANAGEMENT Reduce the length of queues and ensure fair service: With Turn-O-Matic customer flow management from METO your customers are served in turn. Studies show that customers who take a number from the system

More information

David O Brien, CMP Products (David.OBrien@cmp-products.com)

David O Brien, CMP Products (David.OBrien@cmp-products.com) David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?

More information

Plastic tubing, standard O.D.

Plastic tubing, standard O.D. Plastic tubing, standard O.D. Plastic tubing, standard O.D. Features Application The requirements with respect to pressure, temperature, flexibility and environmental influences differ from industry to

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE

More information

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9 CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Pipe and cable fastening with plastic pipe clamps

Pipe and cable fastening with plastic pipe clamps Pipe and cable fastening with plastic pipe clamps Gripping possibilities for the world of pipe and cable fastening CLIC is more than just a plastic clamp: CLIC offers a high-quality system of solutions

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities DEHN + SÖHNE DEHNconductor System No Problems with Proximities DEHNconductor System - New Possibilities for controling Proximities. For preventing dangerous flashovers among parts of external lightning

More information

Pipe Clamps and Accessories

Pipe Clamps and Accessories Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3

More information

Appendix A: Acceptable pipe and fitting materials

Appendix A: Acceptable pipe and fitting materials Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for

More information

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l Geberit Pluvia Syphonic roof rainage system Description Overview Page 42 Geberit Pluvia outlets 6 l Outlets Page 43 Contact foil Page 43 Outlets Page 44 Geberit Pluvia outlets 14 l eating element Page

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier

More information

building applications copper - redefined

building applications copper - redefined building applications copper - redefined copper - redefined The task The development of an innovative tube for the future: economical, environmentally friendly, ecological, completely safe and easy to

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

FLEXWELL Safety Pipe. Pipe systems for installations Technical details

FLEXWELL Safety Pipe. Pipe systems for installations Technical details Pipe systems for installations Technical details Notes 08.04.2013 T page 2 Contents 4.0 4.0 Contents 4.1 System description 4.100 System description FLEXWELL Safety Pipe 4.105 System description FLEXWELL

More information

VULCASCOT RUBBER CABLE PROTECTOR SYSTEMS Technical Data Sheet

VULCASCOT RUBBER CABLE PROTECTOR SYSTEMS Technical Data Sheet VULCASCOT RUBBER CABLE PROTECTOR SYSTEMS Technical Data Sheet Application: To cover and protect all types of cables found in offices, shops, laboratories, factories exhibition halls, warehouses and anywhere

More information

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X. LK Wallbox UNI Push Only intended for LK PE-X Universal Pipe X. LK Wallbox UNI Push 16 Single Article no. 188 06 38 LK Wallbox UNI Push 20 Single Article no. 188 06 39 LK Distance template LK Wallbox UNI

More information

14. Tools and Software

14. Tools and Software 14. Tools and Software System overview: Geberit welding machine MEDIA 160 and tools... 364 System overview: Geberit welding machine UNIVERSAL 315 and tools... 365 14.1 Tools for Geberit Silent-db20 / Geberit

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters

More information

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Ergonomical Polyurethane recoil hose

Ergonomical Polyurethane recoil hose C Recoil PU Hose xx l/ sec 100% PUR -30 C - +60 C Ergonomical Polyurethane recoil hose Assembled in Denmark 2/4/6/8 m Features > > Straight ends of 150 mm / 500 mm > > Top quality PUR raw material 98 Shore

More information

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas BROEN UNIFLEX Fittings FOR BURNIN ASES BROEN UniFlex TM Fittings for burning gases BROEN UniFlex TM Fittings for burning gases LAB Table of Contents Content Page Table of Content 2 Product Overview 3 BROEN

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for

More information

Decree of the Ministry of the Environment on fire safety of ventilation systems

Decree of the Ministry of the Environment on fire safety of ventilation systems THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18

More information

INSTALLATION GUIDE. americanwick.com 800.242.WICK (9425)

INSTALLATION GUIDE. americanwick.com 800.242.WICK (9425) INSTALLATION GUIDE americanwick.com 800.242.WICK (9425) American Wick Drain SITEDRAIN prefabricated drainage products may be installed in a variety of civil construction applications including: retaining

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

CAPACITIVE LEVEL METERS CLM 36

CAPACITIVE LEVEL METERS CLM 36 CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Portable digital microprocessor thermometers with interchangeable probes

Portable digital microprocessor thermometers with interchangeable probes JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

C A B L E P R O T E C T I O N

C A B L E P R O T E C T I O N Safe cable protection! Elematic Cabling Systems produces in own plants a wide range of products for the cable protection, such as wiring spirals, insulated tubing, heat shrinkable tubing, etc. These products

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

Cables and Accessories Selection Guide

Cables and Accessories Selection Guide Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an

More information

Instructions for assembly and use MULTICAL 601

Instructions for assembly and use MULTICAL 601 Instructions for assembly and use MULTICAL 601 www.kamstrup.com 1.1 MID labelling Standard conditions of operation/measuring rates: Meter θ: 10 C 180 C Θ: 3K 170K A pair of resistance temperature sensors

More information

MODEL T200-F18 MODEL T125-F18 Finish Nailers

MODEL T200-F18 MODEL T125-F18 Finish Nailers P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL

More information