The Essential Guide SAREL 2.8
|
|
|
- Lenard Armstrong
- 9 years ago
- Views:
Transcription
1 The Essential Guide SAREL 2.8
2 The Essential Guide SAREL 2.8 1
3 Definition help A material for every environment SAREL: products adapted to all environments Interior industrial unclean environment: STEEL Interior industrial demanding environment: STAINLESS STEEL Extreme industrial and infrastructures environment: INSULATING MATERIALS 10
4 Definition help A material for every environment Steel The response: The Spacial steel range (wallmounting enclosures, floor standing monobloc enclosures, and floor standing suitable enclosures) Interior industrial unclean environment The industrial environment in mechanical plants is particularly demanding in terms of protection of electric and electronic components against dust, oil spray and impacts. This environment therefore requires a range adapted to the applications and an easy implementation. b Universal range, for industry b EMC range, against electromagnetic disturbances (Aluzinc process). b Line of ATEX wallmounting enclosures, for explosive environments. Stainless steel 304L - 316L The response: The stainless steel range (wallmounting enclosures, floor standing monobloc enclosures, PC racks, and control desks) Interior industrial demanding environment The agri-food, pharmaceutical, and petrochemical industries have particularly high requirements in terms of hygiene and corrosion resistance. With two stainless-steel grades: Stainless steel 304L: corrosion resistance and cleanability (commonly used in the food environment). Stainless steel 316L: referred to as marine grade stainless steel : very high corrosion resistance (salty or chlorinated environment). Insulating materials polyester, thermo-plastic (ABS, polycarbonate) The response: the Thalassa range (boxes, wallmounting enclosures, and floor standing monobloc enclosures) Extreme industrial and infrastructures environment Electrical infrastructures and installations are subject to solar rays, rain, salty fog, extreme temperatures, oil spray, chemical and corrosive agents. 11
5 Definition help Overview of the SAREL offer... Overview of the SAREL offer by material Steel Wallmounting enclosures Boxes from mm to mm from mm to mm Steel Screw-on cover Universal ATEX Modular EMC Command and dialogue Terminal enclosure Customized wallmounting enclosure Floor standing monobloc enclosures Floor standing suitable enclosures from mm to mm from mm to mm Universal floor standing monobloc enclosure Universal fitted floor standing suitable enclosure Steel PC rack Floor standing suitable enclosure in kit Automobile application ECM floor standing Customized floor standing monobloc enclosure monobloc enclosure Compartmented floor standing suitable enclosure ECM floor standing suitable enclosure Customized floor standing suitable enclosure Consoles from mm to mm Control desk with headboard Monobloc control desk Modular control desk Control desk to be assembled 12
6 ... by material Stainless steel 304L-316L Insulating materials: polyester, thermo-plastic (ABS, polycarbonate) Thermal accessories Plastic Polyester Customized box Fan Stainless steel wallmounting enclosure Customized wallmounting enclosure Standard polyester wallmounting enclosure Customized wallmounting enclosure Air-air exchanger Air-water exchanger Stainless steel floor Customized floor standing monobloc standing monobloc enclosure enclosure Standard polyester floor standing monobloc enclosure Special productions Standardized street Customized floor floor standing standing monobloc monobloc enclosure enclosure Cooling unit and mini air-conditioner Stainless steel floor standing suitable enclosure Customized floor standing suitable enclosure Heating element Stainless steel PC rack Thermal regulator Stainless steel control desk Customized control desk 13
7 Definition help The 10 key points for properly defining your enclosure Theme 1: environment What type of environment do you install your products in? b Interior, in a clean environment (offices, data centers )... b Interior, in an unclean environment (mechanical plants ) v Plants with discharges: greasy materials, water, impacts, dust... v Disturbed environments: electromagnetic disturbances? Level of mitigation required?... v Explosive atmospheres: What ATEX classification (zone, substances...)?... b Interior, in a demanding environment (pharmaceuticals, agri-food ): decontamination, sterilization notions... v Dry food?... v Moist food?... v Highly corrosive food or process?... v Clean rooms?... b Exterior (roadsides, purification plants ) v Protection against salty fog required?... v Protection against UV?... v Anti-posting?... v Anti-graffiti?... v Total insulation compatible with Class II... v Protection against fire?... v Protection against temperatures?... v To protect against standing water on the door seal do you need a canopy?... b Watertightness/resistance to shocks v IP required?... v IK required?... Theme 2: business profile b Rates and repetitivity v What turnaround time is required of you? Do you store semi-finished products?... v Is your solution always the same?... v Is your machining always at the same place/same dimension?... v What are the total quantities per reference?... v What are the quantities per batch?... v How long does the market last? What are the renewal conditions?... b Deliveries v What is the delivery time desired?... v Partial delivery? Body, door, or full chassis separate?... v Assembled delivery or in Kit form?... H W D Theme 3: dimensions Height Width Depth? b Do you have installation requirements related to the dimensions? v Does the enclosure need to fit in a template?... v Does the enclosure need to fit into a wall?... v Is there a maximum height with plinth?... v Does the enclosure need to have access from different sides?... b Do you need to separate two or more sections from one another? (for example: power on the left, networks on the right?) v Vertically (on the height)... v Horizontally (on the width)... v In this case, do you need to couple several enclosures together?... 14
8 Definition help The 10 key points for properly defining your enclosure Theme 4: fixing Do you fix the enclosures? b To the ground v Do you need access through a trap door for the cables?... v Do you need jacks for cleaning under the enclosure?... v Do you need to move the enclosure?... v Do you need protection against background noise?... b To the wall v To prevent tipping?... v Are your enclosures heavily loaded?... v Do you need a space between it and the wall?... b On the frame of the machine?... b In a low wall?... Theme 5: cable entry b Where do the cables enter from? v Top... v Bottom... v Rear... v Side... b What functions must this cable entry fulfill? v Level of sealing required?... v Tightening frame?... v Lips with steps to adapt to the diameter?... v Multicable ring to pass several cables through the same entry?... v Sealing plug for transport?... v Possibility of entering cables on a round or rectangular plate with large or small diameters side by side?... v Others?... Theme 6: hoisting and handling b How do you install the enclosures on-site? v Hoisting?... v Handling with the pallet?... v Slinging?... v Other?... v Does the rigidity of the unit need to be reinforced?... Theme 7: door and door accessories b What presentation and swing direction for the doors? v Left, right?... v Plain door, glazed?... v Panel or rear door?... b What type of lock do you want? v Keyed lever... v Insert shapes... v Keyed handle... b Do you need an interior door?... b Do you need maintenance accessories? v Door contact... v Door stop... v Door cross rails?... v Lights? - With/Without detector?... - With/Without plug?... v Document pocket... v Door flap... v Door recentering castor... b Do you need cable management accessories?... 15
9 Definition help The 10 key points for properly defining your enclosure Theme 8: interior equipment 1. Automatic functioning b How will the equipment be installed inside your enclosure? v Gain time in drawing and precision: microperforated chassis... v Gain time in drawing: Telequick grille... v Aesthetic, freedom, good mass continuity and EMC mitigation: plain chassis... v Depth adjustment: step slides?... v Total freedom of installation: mixed chassis (side frames + partial grilles + symmetric or asymmetric or combined sections)... v Heavy loads: notched C sections Energy distribution b Low voltage: v Modular chassis?... v Distribution rail: with or without circuit-breaker?... b Medium voltage: v Box with bars and set of bars? Networks b Do you need to have access to the rear of the 19" chassis? v Fixed chassis... v Pivoting chassis... v 19" Fixings... b How do you want to support the light equipment? v Sliding lectern... v Fixed lectern... b How do you want to support the heavy equipment? v Notched C sections?... v Cross rails for heavy loads?... v 3 rows of door cross rails?... b Management of cables v How do you fix your channels on the door? On the vertical rails? On the sections?... v Do you need bases and collars to attach your cables?... v Do you need to protect the cables in the body-door connection?... b Earthing placement v Do you need to earth your chassis?... v Do you need an earth connection?... Theme 9: thermal v Do you need cooling? Heating? Dehumidification?... v Have you made a thermal assessment to proportion the solution based on your environment and your equipment?... Theme 10: customization b Time savings: v Machining: drawning time and transport to machining area time, tooling cost, square cutout: have them taken care of by SAREL... v Fitting of accessories: order time, oversight, fitting, preparation of accessory cases, training: have them taken care of by SAREL... v Delivery... b Aesthetic: v Color: transport to the subcontractor, drying; SAREL sends to paint after the cutout!... b Consult your SAREL partner; together we will complete your projects. 16
10 Une société de Definition help Tools for working together General catalogue Sarel General catalogue of the SAREL offer b SAREL general catalogue 22.7 (ref ) 2. Quickly define a complete standard solution: Steel: Spacial 3D, Spacial 18500, Spacial Insulating materials: Thalassa wallmounting enclosures and floor standing enclosures / Thalassa boxes (S1 2009). Stainless steel: coming soon (S1 2009). Networks: CaSys b Digital rulers downloadable at Click on the dimension of your choice and the references of enclosures and accessories display automatically! 3. Find information on the products: technical sheets, fitting instructions, dxf drawings... Discover the new search engine that makes it possible to find the information you want in just a moment. b Site 4. Rediscover our customized solutions b SAREL customized solutions tryptic 17
11 Industrial steel boxes Overview of steel boxes Boxes Wallmounting enclosures with screw-on covers Name of range IP40 IP44 IP Sealing IP40 IP44 IP66 IP66 IP55 Impact resistance IK08 IK08 IK08 IK10 IK09 Glow-wire test resistance Security wallmounting enclosures Halogen Operating temperatures Dimensions (mm) H 80 to 160 H 80 to 200 H 80 to 400 H 200 or 300 H 180 or 230 H W 80 to 160 W 80 to 200 W 80 to 400 W 300 to 500 W 130 to 210 L D 45 to 65 D 45 to 90 D 45 to 110 P 150 or 200 P 96 or 126 P Size of range 4 dimensions 6 dimensions 15 dimensions 4 dimensions 3 dimensions Transparent cover option Combinability RAL color and 3000 IP40 IP44 IP
12 Industrial boxes in insulating materials Overview of boxes made from insulating materials Thalassa universals adjustables With AB terminals Material and name of range ABS Polycarbonate Polyester and polycarbonate Polyester and polycarbonate Sealing IP66 IP66 IP65 IP65 Impact resistance IK07 IK08 IK10 IK09 Glow-wire test resistance 650 C 750 C 960 C 960 C 960 C for UL and DNV versions Halogen b Very low Operating temperatures 25 C +60 C 25 C +80 C 25 C +130 C 25 C +130 C Dimensions (mm) H H 65 to 325 W 65 to 275 H 65 to 325 W 65 to 275 H 180 to 540 W 270 to 720 H 195 W 295 to 495 P L D 45 to 160 D 45 to 160 D 180 to 230 D 128 Size of range 22 dimensions 20 dimensions 20 dimensions 3 dimensions Transparent cover option b b b - Combinability b b b b RAL colors and 7035 ABS PC Cutting and assembly of your accessories in the plant - see the configurator for Thalassa boxes on pages AB Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting enclosures Boxes electrical panels 19
13 The Essential Guide SAREL 2.8 The guide is a tool aimed at making it easier to select an enclosure and its accessories The guide contains the main questions for properly defining an enclosure and its accessories. A color-code system has been used so that you can find the materials of the different products: boxes, wallmounting enclosures, floor standing monobloc enclosures, and floor standing suitable enclosures. General catalogue Sarel 22.7 This guide is a summary of our offer. For any other need, do not hesitate to contact a SAREL representative. You can also find everything we offer online at, where you will find our drawings in DXF format, our product files, and all the information you might need. 2
14 Industrial steel boxes Boxes IP40, IP44, IP66, Wallmounting enclosures with screw-on covers, and security wallmounting enclosures Selection guide for boxes IP40, IP44, and IP66 Internal dimensions (mm) boxes IP44 boxes IP66 H W D boxes IP40 With entries No. of nozzles Bare With plate fasteners With 2 uprights Nozzles for IP66 plates (1) (1) (1) * (1) (1) * * Consult our regional branch. (1) Add a ground screw on the cover/body External dimensions (mm) H W D wallmounting enclosures with screw-on covers Wallmounting enclosure Chassis reference dimensions (mm) H W D Plain Microperforated Perforated Mixed Security wallmounting enclosures 24300, IP55/IK09 Internal dimensions (mm) wallmounting enclosures wallmounting enclosures with 3 mm lateral double bar locks H W D Plain door Viewing door Plain door Viewing door Viewing door with 2mm thick window
15 Industrial boxes in insulating materials adjustable boxes Selection guide for adjustable boxes Boxes External dimensions (mm) Number of closure points boxes Full chassis H W D Opaque Transparent reference cover cover perforated plates modular bibs Number of rows number of modules Wallmounting enclosures Wall fixing lugs in stainless steel Wall fixing lugs in stainless steel Cover closure screw Description Slotted-head screw Wing screw Sealable triangular screw Coupling frame Opening (mm) b Frame delivered with 2 coupling legs. Floor standing monobloc enclosures Floor standing suitable enclosures Thermal packaging of electrical panels Cable gland plate Length (mm) Technical appendices 21
16 Industrial boxes in insulating materials Accessories for adjustable boxes Hinges b Set of 2 hinges. b For 180 door opening. Transport handle for boxes Accessories b Button-bolt with security lock and key no.1442 E. b Triangular key. b Set of 2 aeration louvers, supplied with fastening screws and the drilling template. Description Button-bolt Aeration louvers Triangular key Coupling examples Note: The boxes may be assembled coupled horizontally or vertically using the juxtaposition frames and coupling legs. 1 Cable gland plates equipped with cable gland 2 Hinge 3 Coupling leg modular box 5 Cable gland plate 6 Coupling frame 22
17 Industrial boxes in insulating materials AB, IP165 adjustable boxes Selection guide for AB, IP65 adjustable boxes Technical appendices Thermal packaging of electrical panels Boxes External dimensions (mm) AB, IP165 adjustable Full chassis reference section coupling frame H W D boxes Symmetrical Asymmetrical Wallmounting enclosures Threaded sections b Set of 2 sections. b M5 threading. Floor standing monobloc enclosures Floor standing suitable enclosures Wall fixing lugs b Set of 4 wall fixing lugs. b Material: insulating materials. 23
18 Industrial boxes in insulating materials Selection guide for Thalassa boxes Thalassa IP66 universal boxes Internal dimensions (mm) Materials H W D Body Cover ABS IP66 IK07 Fire 650 C PC IP66 IK08 Fire 750 C Boxes with buttons, equipped, in ABS, IP54 PC UL and DNV IP66 IK08 Fire 960 C Cover opaque Cover transparent Cover opaque Cover transparent Cover opaque Cover transparent New references External dimensions (mm) Description H W D Emergency stop Start/stop Raise/lower/stop Boxes for buttons, not equipped, in ABS External dimensions (mm) Description H W D hole, gray box hole, yellow box holes holes Boxes for flasks, in polycarbonate Total Internal dimensions (mm) IP66 - IK08 with cover H W D Body Cover Opaque Transparent fl fl fl fl.21 Gasket kit for flask FL Gasket kit for flask FL
19 Industrial boxes in insulating materials Selection guide for accessories Dimensions (mm) Set of 2 hinges Set of 4 Plate in Insulating plate Support bar for terminal boards H W D fixing lugs galvanized steel (length) (175 mm) (175 mm) (175 mm) (175 mm) (175 mm) (175 mm) (225 mm) or (175 mm) (275 mm) or (225 mm) (275 mm) or (225 mm) (275 mm) (275 mm) Screw ref.: Stands-offs or spacers 4 hole terminal blocks Black phase Blue neutral Green ground Fixings Set of 100 screws Ø 4 mm Pozidrive and slotted Set of 4 15 mm spacers Set of 4 20 mm spacers Set of 4 30 mm spacers Set of 4 15 mm autothreaded stand-offs Set of 4 20 mm autothreaded stand-offs Set of 4 30 mm autothreaded stand-offs Set of 50 screws for stand-offs and spacers Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting enclosures Boxes IP68 cable gland ISO IP67 entries Type of IP68 cable gland M M M M M M Type of ISO IP67 entry M M M M M M Thermal packaging of electrical panels Ventilation and coupling accessories Ventilation louvers m 3 /h IP Ventilation louvers m 3 /h IP Coupling kit IP Technical appendices Coupling kit Ventilation louver 25
20 Industrial boxes in insulating materials Configurator for Thalassa boxes Send the document to your local SAREL sales office by or fax Date: / / YOUR CONTACT DETAILS First/last name: Company: Address: Tel: Fax: Definition of the box Dimensions Total quantity for the project for batches of (minimum batch to be validated by us) Material b ABS b Polycarbonate b Polycarbonate version UL and DNV Cover b Opaque b Transparent (from the dimension mm) boxes boxes Internal dimensions (mm) Body/cover dimensions (mm) H W D P1 P D P1 P2 W H Color for boxes in ABS Standard color RAL 7035 Special colors for boxes in ABS Indicate the color of the closure screws in 2.1 RAL 3000 RAL 6018 RAL 1021 RAL 7036 RAL 7016 RAL 9003 RAL 9010 RAL 9005 If a special color is needed for the boxes in polycarbonate: ask us. Think about defining the color of accessories in 2.1 Color in material Other RAL color: Definition of accessories not requiring a cutout All the accessories offered below are fitted by default, unless indicated otherwise. Some accessories may require a specific placement. You are advised to define it on a drawing. To help you, we can send you a definition drawing for the box desired. At the bottom of the form you will find the field enabling you to request it (following page) Cover closure Standard screw Standard screw and metal handles not fitted * Screw with square impression of * Screw with triangular impression of * Screw with double bar impression of Set of 2 hinges*** ** 3 Code * Available from dimension / ** CNOMO / *** only for covers of 20 and 40 mm in height RAL 9005 W= A B C D indicate the code H = 26
21 Industrial boxes in insulating materials Configurator for Thalassa boxes Wall fixing Fixing in sealed zone Fixing in non-sealed zone Vertical fixing legs Horizontal fixing legs RAL9005 W= W= legs Specify H and W (mm) H = H = Boxes Fitting plate and rails. Plate (from the dimension ) Symmetrical Rail Symmetrical Rail Symmetrical rail Asymmetrical rail (from H or W 105) (from H or W 105) (from H or W 225) (from H or W 225) length length length length Aluminum telecom section (from H or W 275) length steel quantity quantity quantity quantity quantity insulating to place not fitted Customization of the plate upon request Wallmounting enclosures Interior fixings height 15 mm 20 mm 30 mm Self-tapping uprights (kit of 4) Cross struts (kit of 4), not fitted quantity quantity 3 - Definition of cutouts and accessories not requiring drilling All the accessories offered below are fitted by default, unless indicated otherwise Cable entries Code Diameter M12 M16 M20 M25 M32 M40 Cablegland IP68 for 1 cable + nut Multicable ring for cable gland IP68 Plug + nut Transport plug ISO IP67 sealed entries Juxtaposition kit (from depth 80) H J K L M N quantity quantity quantity quantity quantity quantity ø D23 D29 D36 D44 EVA IP55 sealed entries O quantity p. p. p. parts Don't forget to send us the location of components face by face (sketches below) Floor standing monobloc enclosures Floor standing suitable enclosures Cutouts Code form P Q R S T V Simple cutouts X R Y Y X X R X X X Y R Y R Number of cutouts on the body on the cover Thermal packaging of electrical panels M Threading Code form = U Countersinking X / Y mini = mm, R mini = 1.5 mm, M mini = M3 45 extension... (for example: TC) Ask Us So we can establish a precise estimate, please place your cutouts and accessories on the following page views. In case of an order, a definition drawing will be necessary for fabricating the box. We can send you this definition drawing for the box desired, so you can place your cutouts and other graphic specifications on it. Technical appendices Drawing desired in format:....dxf (Autocad, Solidworks,...)....pdf (Acrobat) 27
22 Industrial boxes in insulating materials Configurator for Thalassa boxes 4 - Definition of markings Our laser equipment enables markings with great precision with infinite protection over time. Please write your text in the insert opposite. For more clarity, the digitial file with your logo should be sent to us. Write your text here: 5 - Definition of the packaging b Wrapping in overpackaging b Lack of individual packaging separate body and cover (packaging by default) body and cover assembled 6 - Sketch So we can establish a precise estimate, please place your cutouts and accessories in the tables below. If an order is placed, a definition drawing will be necessary for fabricating the box. Cover Bottom face Code Dimensions (mm) Qty. Code Dimensions (mm) Qty. Cover Right face View from below Left face Code Dimensions (mm) Qty. D body W Code Dimensions (mm) Qty. H Body Rear face Code Dimensions (mm) View from View from right left Top face Qty. View from Code Dimensions below (mm) Qty. example of capture Right face Code Dimensions Qty. (mm) L M20 3 R
23 Definition help Configurator for Thalassa boxes 7 - Other choices of accessories Description of your need: Possible scheme: 8 - Download your schemes in.dxf format from the "Thalassa Boxes" CD-ROM available from SAREL Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting enclosures Boxes electrical panels 29
24 The Essential Guide SAREL 2.8 Summary * * * * * * * SAREL protects your electrical equipment... 4 Customized products: configured and specific... 8 Definition help Boxes Overview of steel boxes Overview of boxes made from insulating materials Configurator for Thalassa boxes Wallmounting enclosures Overview of the wallmounting enclosures Selection guide for wallmounting enclosures Configurator for Spacial 3D wallmounting enclosures Configurator for Thalassa wallmounting enclosures Floor standing monobloc enclosures Overview of the floor standing monobloc enclosures Selection guide for steel and stainless steel floor standing monobloc enclosures Selection guide for polyester floor standing monobloc enclosures Configurator for floor standing monobloc enclosures Configurator for Thalassa floor standing Monobloc enclosures Floor standing suitable enclosures Overview of the floor standing suitable enclosures Selection guide for fitted steel floor standing suitable enclosures Selection guide for fitted stainless steel floor standing suitable enclosures Kit Configurator for Spacial 6000 floor standing suitable enclosures Man-machine dialogue solutions Man-machine dialogue wallmounting enclosure d Spacial 6000.PC racks Spacial steel and stainless steel control desks Thermal packaging of electrical panels Natural ventilation Forced ventilation Heating elements Thermal regulation Exchangers Electronically controlled cooling unit Mechanically controlled cooling unit Common accessories Technical appendices The 4 key points of thermal management * Making your thermal assessment Forced ventilation Software to help with calculation and selection * Have your thermal assessment made by SAREL Definition of degrees of protection Index of references Definition-help pages marked with a red tab. * 3
25 Steel, stainless steel, and polyester wallmounting enclosures Overview of the wallmounting enclosures Material Steel wall mounting enclosures Criteria Spacial 3D universal wallmounting enclosures Spacial 3D universal wallmounting application enclosures Modular With terminals With screw-on cover For dialogue man-machine Customized wallmounting enclosures Operating environment Inside, industrial environment Sealing IP66 (IP55*) IP66 IP66 IP66 IP55 IP66 (IP55*) Impact resistance IK10 or IK08** IK08 IK10 IK10 or IK08** IK10 IK10 or IK08** Dimensions (mm) H 300 to 1400 W 200 to 1200 D 150 to 400 H 400 to 1000 W 300 to 800 D 150 H W 200 to 800 D 150 H 300 to 800 W 600 D H 300 to 800 W 300 to 600 D Size of range 120 references 10 references 8 references 20 references 8 references - Transparent/glazed door option b b - b - b Combinability b b b - - b Color as required * IP55 for a double door. ** Glazed door version. Spacial 3D universal New: 13 new dimensions Spacial 3D modular Spacial 3D with terminals Spacial 3D with screw-on cover Spacial 3D Command and dialogue Spacial 3D customized To discover The new Spacial 3D mini-website: b Download your schemes in.dxf format, also available at b Make your modifications b SAREL will make your cutouts for you 30
26 Steel, stainless steel, and polyester wallmounting enclosures Overview of the wallmounting enclosures Material Steel wallmounting enclosures Stainless steel wallmounting enclosures Polyester wallmounting enclosures Criteria Spacial 3D universal wallmounting enclosures ECM wallmounting enclosures brushed 304L 316L glass-bead blasted Thalassa Operating environment Inside, industrial environment Inside, outside, pharmaceutical, chemical, Inside, outside, infrastructures agri-food Sealing IP66 IP54 IP66 IP66 IP66 Impact resistance IK10 IK10 IK10 IK10 IK10 or IK08* Dimensions (mm) H 300 to 1000 W 200 to 800 D 150 to 300 H 400 to 1200 W 300 to 800 D 200 to 400 H 300 to 1200 W 200 to 1000 D 150 to 300 H 300 to 1200 W 200 to 1000 D 150 to 300 H 310 to 1035 W 255 to 850 D 200 to 350 Size of range 10 references 9 references 22 references 16 references 24 references Transparent/glazed door option b Combinability b RAL color * Glazed door version. Boxes Thermal packaging of electrical panels Wallmounting enclosures Floor standing suitable enclosures Floor standing monobloc enclosures Cutting and assembly of your accessories in the plant - see the configurator for Spacial 3D wallmounting enclosures on pages Technical appendices 31
27 The wallmounting enclosures The SAREL universal wallmounting enclosures offer: Spacial 3D wallmounting steel enclosures b Live span. b Aesthetic. b Selection. b Time savings. Stainless steel wallmounting enclosures b Sealing. b Robust and durable. b Practical and time-saving. b Compatible with the other ranges. b Sterile. b Easy to clean. b Corrosion resistant. b Aesthetic. Thalassa polyester wallmounting enclosures b Sealing. b Life span. b Ease. b Selection. 32
28 steel, stainless steel, polyester Spacial 3D steel wallmounting enclosures The universal monobloc wallmounting enclosure Sealing b IP66, polyurethane seal and double door fold. b 3 locking points from heights of 600 mm. Life span b Polyester paint and good protection against UV. b Coated hinges, aluminum pins. Boxes Select b Plain door: 54 references. b With plain chassis: 54 references. b With glazed door: 45 references. Stainless steel wallmounting enclosures Thalassa polyester wallmounting enclosures Time savings: b Configured offer: other colors. b Fitted accessories, machinings made in other dimensions. Finishes b Two types of steel referenced: v brushed 304L. v 316L microbeaded. b Painted in the RAL range (by request). Sealing b IP66 (EN 60529) protection level: complete protection against dust and water spray. b Polyurethane or neoprene seal. b Front profile in form of gutter. b Three locking points for the double door. Robustness and durability b External mechanical impact resistance: IK10/IK08 (glazed door). b Door profile or reinforcement frame. b Stainless steel hinges Life span b Fiberglass reinforced polyester. b Hot press moulded. b Designed to resist the worst climatic, industrial, and chemical conditions. Sealing b IP66, integrated top and bottom canopies, protecting the door and the seal. b Polyurethane seal. b Closure according to wallmounting enclosure reference. Ease b Door reversibility by turning over the wallmounting enclosure. b Opening to 180. b Easily unhingeable. b 4 housings for the inserts and possibility of positioning on the DIN rail every 25 mm. Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting Cases enclosures electrical panels 33
29 Steel, stainless steel, and polyester wallmounting enclosures Technical descriptions of the wallmounting enclosures Interior installation, clean and unclean premises (industrial environment) The response: Spacial 3D universal steel wallmounting enclosures Interior installation, clean and unclean premises (agri-food, pharmaceutical, chemical environment) Interior or exterior installation (infrastructures and industry) The response: Spacial 3D universal wallmounting enclosures The response: Thalassa polyester wallmounting enclosures Technical features b Sealing: IP66 (wallmounting enclosures with single door) and IP55 (wallmounting enclosures with double door). b Protection against external impacts: v IK10: wallmounting enclosure with plain door, v IK08: wallmounting enclosure with glazed door (thickness 4 mm). b Optimized closure and opening: v profiles perforated on the door 2 vertical profile from H = 400 mm, 2 vertical profiles and 2 horizontal profiles from W = 800 mm, v Removable and reversible door, 120 opening. Easy rod inversion, v maximum load: 50 kg/m 2, v standard wallmounting enclosure supplied with a double bar lock, v Equipotential connection between the door and the body using M6 16 earthing screws. b Fixing: direct wallmounting using 4 holes (Ø 10 mm), using 4 fixing lugs (to be ordered); sealing plugs ensuring the IP. b Space optimization: 4 M8 supported rear pins 25 for fitting chassis and step slides saving a rear space of 10 mm. b Cable gland plate pre-squared to facilitate drilling and ensure maximum surface access. Certifications b EN 62208, LCIE (enclosure standard), CUL, BV, BNV, LR, GL. b NEMA type 4,4X (single door) and NEMA type 12,12K, 13 (double door) according to UL 508A. Finish b Structured, polyester powder, RAL 7032 gray color. Technical features b IP66 Sealing. b Protection against impacts: IK10 wallmounting enclosure with plain door. IK08 wall mounting enclosure with glazed door. b Optimized closure and opening: v standard lock by 3 mm double bar (chrome zamac), v door swing to right or left thanks to fully symmetrical wallmounting enclosure. b Interior or exterior installation. b Direct wall fitting or using fixing legs (to be ordered), Brushed finish b Monobloc wallmounting enclosure in AISI 304L stainless steel. b Full corrosion resistance thanks to Scotch Brite mechanical brushed polishing. b Reinforced door using two vertical profiles (from 600 mm in height), with drillings Ø 4.25 mm every 25 mm. Microbeaded finish b Monobloc wallmounting enclosures fabricated in AISI 304L or AISI 316L stainless steel. b Main properties: considerably limiting the adherence of any substance, enabling disinfection, even sterilization. b Wall mounting enclosure 15/10 mm, with neoprene seal 20 6 stuck and hinges in 316L seal. b Door reinforcing frame from 600 mm width, 2 and 3 closure points from height 500 and 1,000 mm respectively. Technical features b IP65 sealing for wallmounting enclosures of 300 mm high and IP66 for the rest of the range. b Impact resistance: plain door IK10 door with porthole IK08 (5 joules). b Temperature protection: 50 C +150 C. b Total insulation compatible with class 2. b Optimized closure and opening: reversibility of door opening by inverting the wallmounting locking, locking device in non-sealed zone guaranteeing IP66 over time. b Best protection against water spray and rain thanks to integrated top and bottom canopies (obtained by molding). b Common accessories with those of the Spacial 3D range. Finish b Smooth; RAL 7032 color. 34
30 Steel, stainless steel, and polyester wallmounting enclosures Define your wallmounting enclosure Environment b Use Internal or External?... b Type of ambient environment: Normal, Saline, Corrosive (which products?)... b Is a canopy required? (Y/N)... b Type of material required (Steel/ Stainless Steel/ Polyester)... Boxes Technical definition b Height (mm)... b Width (mm)... b Depth (mm)... b IP... b IK... b Color RAL... b Type of coating... b Stainless steel finishes: brushed or microbeaded... b Type of lock, to be specified... b Visibility: Glazed door, Window... b Type of chassis: Plain, Telequick, Other... b Loads to be borne: by enclosure, doors and panels... b Electrical continuity by means of grounding strip, or other (to be specified)... b Cable entry via cable gland plate... b Fitting by fixing Lugs or Direct fixing... b Lighting (Y/N)... Wallmounting Cases enclosures Floor standing monobloc enclosures Customization. See customization help on pages 48 to 51 b Description of machinings (plans, sketches)... b Electrical continuity by means of grounding strip, or other (to be specified)... b Standard accessories fitted... b Specific accessories to be supplied (plans, sketches)... b Application of image: screen print, sticker... Floor standing suitable enclosures Thermal b Air louvers or Ventilation grilles... b Forced ventilation... b Heating element... b Air-conditioning... b External temperature range... b Internal temperature range... Thermal packaging of electrical panels Logistics b Place of delivery... b Special delivery information?... b Special unloading information?... Technical appendices 35
31 Steel, stainless steel, and polyester wallmounting enclosures Selection guide for wallmounting enclosures Dimensions (mm) No. Doors IP Spacial 3D IP66 wallmounting enclosures RAL 7032 H W D Plain door Glazed door Without chassis With chassis Without chassis Spacial 3D IP66 wallmounting enclosures RAL 7035 Plain door Without chassis With chassis IP66 Stainless steel wallmounting enclosures brushed 304L stainless steel Plain door Without chassis Glazed door Without chassis 316L microbeaded stainless steel Plain door Without chassis Thalassa IP66 wallmounting enclosure Plain door Without chassis Glazed door Without chassis * 59415* *IP65 polycarbonate wallmounting enclosure. 36
32 Steel, stainless steel, and polyester wallmounting enclosures Selection guide for accessories Material Steel L stainless steel Wallmounting enclosure dimensions (mm) Chassis 19 Châssis Wallfixing lugs S3D Boxes H W Telequick Micro- Plain perfora- galvanized ted grille Mixed symmetrical Fixed No. U Pivoting Type B B B B B B B B A A 25911* * B B B A A B B A 25912* * A 25912* * A 25912* * A 25912* * A B B A 25913* * A 25913* * A 25913* * A 25913* * A A A A A A 25914* * A 25914* * A 25914* * A * A * A * A A A A A * A * A A A * Standard 19" Chassis can only be fitted on steel wallmounting enclosures. No. U Door stop S3D Ref Wall fixing lugs Lock Type of stainless steel L L Ref. Description Material mm double bar 100% Stainless steel mm male triangle 100% Stainless steel mm male square 100% Stainless steel mm male square 100% Stainless steel Wall fixing lugs, polyester Ref , except for wallmounting enclosure of 200 width, stainless steel (heavy loads) Ref Adhesive drawing pockets Screw for 19" chassis see page 46 Clip-nuts for Telequick grille Ref Door contact S3D Ref Clip on nut Ventilation See pages 103 to 104 Handle with keys, cylinders 1242E S3D Ref Locks, Key 1242E Ref Document pocket Format Thickness (mm) A A A3 35 Description M6 screws x 16 and washers Lock-nut M Screws M6 + washers + nuts For screws M M M M6 Self-piercing screws S3D Ref Lighting see page 113 Lamp Ref Wallmounting Cases enclosures Floor standing monobloc enclosures Floor standing suitable enclosures Thermal packaging of electrical panels Technical appendices 37
33 Steel, stainless steel, and polyester wallmounting enclosures Accessories Assembly accessories Canopy for Spacial 3D steel wallmounting enclosures For wallmounting enclosure (mm) Width Protects the seal Depth Canopy for stainless steel wallmounting enclosures Recommended for exterior installations For wallmounting enclosure (mm) Width Depth Coupling accessories Coupling frame for Spacial 3D steel wallmounting enclosures To expand the dimensional selection Description Single coupling kit Coupling frame * Coupling frame ** * From 600 mm height 300 mm depth. ** From 800 mm height 300 mm depth. Coupling frame for Thalassa polyester wallmounting enclosures Maintains an IP55 Frame External dimensions H W D (mm) Passage For wallmounting enclosure reference and
34 Steel, stainless steel, and polyester wallmounting enclosures Accessories Accessories for the base Support foot for Spacial 3D steel wallmounting enclosures Description Support foot Boxes Support foot Adaptor plate for support foot for Spacial 3D steel wallmounting enclosures Adaptor plate For wallmounting enclosure (mm) Width Depth Wallmounting Cases enclosures Support foot for Thalassa polyester wallmounting enclosures for wallmounting enclosures of 400 width Description Ground fixing foot Cable guide arch Floor standing monobloc enclosures Ground fixing foot for Thalassa wallmounting enclosure Cable entry accessories Cable gland plate for Spacial 3D steel wallmounting enclosures Quick entry of cables Floor standing suitable enclosures For wallmounting enclosures Cable gland plate reference Width (mm) Depth (mm) Standard ISO knockouts Aluminium With membrane entries Thermal packaging of electrical panels Cable gland plate for Thalassa polyester wallmounting enclosures Cable gland plate reference and For wallmounting enclosure reference Technical appendices 39
35 The Essential Guide SAREL 2.8 SAREL protects your electrical equipment Chosing a world leader Since 1956, SAREL's business has been to design, produce, and sell enclosure systems to physically protect, create, and install equipment for industrial automatic functioning, electrical distribution, and VDI networks, in all environmental conditions. In all its ranges of industrial boxes, wallmounting enclosures, floor standing monobloc enclosures, floor standing suitable enclosures, and control desks, in different materials: steel, stainless steel, polyester and thermoplastic or on its installation equipment, boxes, and accessories, SAREL is among the world leaders in its field and affirms itself as the specialist in sealing. Better meeting the needs of professionals in construction, industry, VDI networks, and infrastructures Listening, closeness, innovation, and presence: SAREL has long cultivated the values that make it close to its customers and promote the development of partnerships, taking the greatest care in the quality of its responses to the needs of professionals. Users, consultants, general contractors, or distributors, SAREL integrates your expectations in its overall company approach through: b Products, equipment, and materials which adapt easily to all circumstances, for all types of configurations and applications, with all quality, reliability, rapidity and ease of implementation assurances. b Services which strengthen the personalization of products according to your requirements and make it possible to provide the proper answers to your specific needs with the greatest flexibility and highest levels of quality. In this approach, SAREL contributes to its customers' competitivity. 4
36 Steel, stainless steel, and polyester wallmounting enclosures Accessories Plate IP65 for passing cables Up to 29 cables in a single entry Cutouts (mm) No. openings Passage of cables Ø (mm) 3 to to to to to One single, easy to make round cutout No. Ø Passage of cables Ø (mm) openings Cable pass through 3 to to to 5 to to to (mm) ISO IP68 cable gland Ø 1-cable cable gland Multicable ring Gasket Sealing plug Ref. Ø min / max Ø drilling ** Ref. No./ Ø (mm) (mm) Transport plug M / ( ) M / ( ) M / ( ) M20 (*) / ( ) M / ( ) M / ( ) M / ( ) * highly fire-resistant cable gland for red boxes. ** (x + x) = tolerance. Hoisting accessories Lot of 2 lifting eyes for Spacial 3D wallmounting enclosures in steel Ease of lifing for heavy loads Description Set of 2 lifting eyes
37 Steel, stainless steel, and polyester wallmounting enclosures Accessories Door and door accessories Interior door for Spacial 3D wallmounting enclosure in steel and in stainless steel Double bar lock closure For wallmounting enclosure (mm) Boxes Width Depth Wallmounting Cases enclosures Interior door for Thalassa polyester wallmounting enclosures For wallmounting enclosure (mm) Width Depth Floor standing monobloc enclosures Door cross rail for Spacial 3D wallmounting enclosures in steel and in stainless steel Fastening with 2 sell-tapping screws Door width (mm) Lot of 10 parts Floor standing suitable enclosures Thermal packaging of electrical panels Channel support Ø22 Description channel support Ø22 Lot of 10 parts Technical appendices 41
38 Steel, stainless steel, and polyester wallmounting enclosures Accessories Locking accessories Locking system for Spacial 3D steel wallmounting enclosures Description mm square mm square mm square mm double bar mm double bar mm triangle CNOMO mm triangle Insert shapes Description E A A A Handles with keys Locking system for stainless steel wallmounting enclosure Description Material mm double bar (replacement) Chrome Zamack mm double bar 100% Stainless steel mm male triangle 100% Stainless steel mm male square 100% Stainless steel mm male square 100% Stainless steel Button-bolt 1242 E Chrome Button-bolt 1242 E Polyamide Locking systems for Thalassa polyester wallmounting enclosures with closure escutcheon and h < or = 850 Insert shapes Description mm square mm square mm square mm double bar mm double bar mm triangle CNOMO mm triangle Locking levers with cylindrical barrel Locking levers with cylindrical barrel E key key key key A key A key A key 42
39 Steel, stainless steel, and polyester wallmounting enclosures Accessories Earthing accessories Fastening leg for earth collector Fitting on front side of wallmounting enclosure Description Spacial 3D earth bar support kit Lot of 5 sets (10 parts). Boxes Description Terminal strip and earth bar support kit Lot of 2 parts (1 set). Direct fitting on chassis 1 leg= 2 functions (terminal board + earth bar) Wallmounting Cases enclosures Combined fastening leg for earth collector Terminal strip support bracket Description Terminal strip support bracket Lot of 2 parts. Floor standing monobloc enclosures Bracket, section, and terminal strip Floor standing suitable enclosures Technical appendices Thermal packaging of electrical panels 43
40 Steel, stainless steel, and polyester wallmounting enclosures Accessories Earthing braids Section (mm²) Length (mm) Width (mm) Ø holes (mm) Order in multiples of 10 parts. Earth connections Section (mm²) Length (mm) Order in multiples of 10 parts. Ø terminal spade tag holes (mm) 44
41 Steel, stainless steel, and polyester wallmounting enclosures Accessories Installation accessories Notched bars for Spacial 3D wallmounting enclosures in steel and in stainless steel Chassis depth adjustment For enclosure depth (mm) Boxes (1) (1) Lot of 2 bars and 2 brackets for fitting 2 chassis with depth adjustment in wallmounting enclosures of widths of 1000 and 1200 mm and 300 deep. Step slides for Thalassa polyester wallmounting enclosures For wallmounting enclosure depth (mm) Wallmounting Cases enclosures Sections Description Asymmetrical, 2 m length Floor standing monobloc enclosures Sections Combined section Symmetrical (A), length 2 m Symmetrical (B), length 2 m DIN section, length 2 m perforated Combined section, length 2 m Lot of 10 parts. Type A = Type B = Floor standing suitable enclosures Technical appendices Thermal packaging of electrical panels 45
42 Steel, stainless steel, and polyester wallmounting enclosures Accessories Fixings Sliding 1/4 turn nuts b Clip-on on combined section. b Two models available, M3/M4 or M5/M6. 1/4 turn nuts M3/M4 M5/M Lot of 100 parts and Clip-on nuts b Attach on combined sections and symmetrical sections. ratcheting nuts M4 M5 M Lot of 100 parts to Sliding 1/4 turn nuts b For asymmetrical sections. 1/4 turn sliding nuts M4 M5 M Lot of 100 parts to Hexagonal head screw b Slotted-head screw with attached washer. Order in multiples of 100 parts. Thread hexagonal head slotted screw with attached washer, length (mm) M M M M (1) (1) without attached washer. 46
43 Steel, stainless steel, and polyester wallmounting enclosures Accessories Cable management accessories Plastic cable supports Direct clipping on rail Width (mm) No. maximum of cables Lot of 10 parts. Boxes Spiral band b Spiral band for bundling cables. b Enables the passage of cables between the body and the door. b Packaging: 50 m. Color Clamp area (mm) Interior (mm) Exterior (mm) colorless 12 to Wallmounting Cases enclosures Floor standing monobloc enclosures Cable passage tube b Cable passage tube with lengthwise slit for bundling cables. Enables the passage of cables between the body and the door. b Packaging: 25 metres. Color Ø interior A (mm) Ø exterior B (mm) gray gray gray Floor standing suitable enclosures Cintura cable ties for cross rails. Length (mm) Width (mm) Ø maximum clamp (mm) Lot of 100 parts. Thermal packaging of electrical panels Self-adhesive bases For cable tie maximum width (mm) Lot of 100 parts. Technical appendices 47
44 Steel wallmounting enclosures Configurator for Spacial 3D wallmounting enclosures Spacial 3D configured wallmounting enclosures Send the document to your local SAREL sales office by or fax YOUR CONTACT DETAILS First/last name: Company: Address: Tel.: Fax: QUANTITY OF WALLMOUNTING ENCLOSURE(S) REFERENCE CATALOGUE DIMENSIONS (mm) H W D GLAZED DOOR PLAIN DOOR COLOR SELECTED ACCORDING TO LIST RAL: NF: E REINFORCED ANTICORROSION COATING HINGES ON THE LEFT REF. CLOSURE AND/OR DESCRIPTION CANOPY PAINTED IN THE COLOR OF THE ENCLOSURE GROUND CONNECTION WALL FIXING BRACKETS REF. OUTLET GRILL REF. QTY INTERIOR DOOR DOOR CROSSPIECE DOOR REAR DOOR CONTACT FAN REF. ANTI-INSECT GRILLE LOUVER PLATE REF. FITTED CABLE GLAND DIAMETER (mm) Ø 12 Ø 16 Ø 20 Ø 25 Ø 32 Ø 40 QTY QTY QTY QTY QTY QTY ENTRIES WITHOUT CONNECTORS REF DOOR SCHEME BACK CHASSIS PLAIN PERFORATED SCREEN PRINTED MICROPERFORATED FITTED 19 CHASSIS FIXED PIVOTING FITTED THERMOSTAT PLINTH PLINTH HEIGHT 100 MM PLINTH HEIGHT 200MM PAINTED IN THE COLOR OF THE ENCLOSURE 48
45 Steel wallmounting enclosures Configurator for Spacial 3D wallmounting enclosures Spacial 3D configured wallmounting enclosures Boxes HELP WITH DEFINING MACHININGS For a faster estimate, please indicate your cutouts on the different sides, then fax the drawing to your SAREL sales branch. For producing your configured wallmounting enclosures with cutouts, the DXF drawings are needed. DRILLING ON THE DOOR QTY ON THE CHASSIS QTY ON THE BODY QTY ON THE CABLE GLAND PLATE QTY Download the configuration sheets and the DXF drawings from the website Send then back to your SAREL agent indicating your modifications. Essential if ordering to take advantage of the configuration timescale. For any other needs or any other constraints - get in touch with us. SAREL also offers customized solutions to meet your other requirements. Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting Cases enclosures electrical panels 49
46 The Essential Guide SAREL 2.8 SAREL protects your electrical equipment Four industrial sites in a progress dynamic In its two French plants, as in its two Spanish plants, quality receives a priority emphasis in the SAREL industrial policy. It is expressed at all levels of the company in order to better satisfy its customers. It is demonstrated by the ISO 9001 certification for the design, manufacturing, and distribution of products, and the ISO certification for environmental protection. Mastery of four industrial trades To effectively meet the needs of professionals in electricity, automated systems, electronics, and VDI and telecom networks, SAREL guarantees the mastery of the industrial trades necessary to the fabrication of its products through Quality Assurance. Spread out over four sites, of a total surface area of 55,000 m 2, the industrial activities are conducted in separate workshops. Each of them integrate dedicated production lines with specific functions and production equipment: b Sheet metal: sheet metal manufacture, painting, and packaging are just-in-time, integrating the technologies of stamping, steel sheeting, folding, and welding with polyurethane joint placement according to a patented process. b Injection and extrusion of plastics: bimaterial and trimaterial molding, organization by production batches, automatic assembly machines. b Stainless steel, brushed or microbeaded sheet metal. b Transformation of thermoset plastics: heat compression of SMC glassfiber reinforced polyester. Quality Assurance close to the production process From order processing to shipping, the Total Quality approach covers the design, manufacturing and shipment of products. 5
47 Polyester wallmounting enclosures Configurator for Thalassa wallmounting enclosures Configured polyester Thalassa wallmounting enclosures Send the document to your local SAREL sales office by or fax YOUR CONTACT DETAILS First/last name: Company: Address: Tel.: Fax: QUANTITY OF WALLMOUNTING ENCLOSURE(S) GLAZED DOOR HINGES ON THE LEFT PLAIN DOOR REFERENCE OR CATALOGUE DIMENSIONS (mm) HEIGHT WIDTH 307 / 164 / 430 / 200 / 530 / 200 / 647 / 250 / 747 / 300 / 847 / 300 / 1,056 / 350 / PROF Choice of standard accessories of the configuration Also check the red box m for accessories fitted in the plant. WALL FIXING BRACKETS POLYESTER STAINLESS STEEL BACK CHASSIS PLAIN PERFORATED MODULAR CHASSIS m m m OUTLET GRILLE REF m INNER DOOR (fitted) DOOR SCHEME FAN REF THERMOSTAT REF m LOCK MODIFICATION 7 mm SQUARE 8 mm SQUARE 8 mm TRIANGLE PADLOCKING DRAINING m STEP SLIDES m INTERIOR VENTILATION LOUVERS (SET OF 2) m 50
48 Polyester wallmounting enclosures Configurator for Thalassa wallmounting enclosures Configured Thalassa wallmounting enclosure Boxes Machinings For a quick calculation, please indicate the total number of machinings required: ON THE BODY (BACK AND SIDES) ON THE DOOR FOR THE GRILLES, FANS, DRAIN, AND AERATORS OTHER MACHININGS NB: Each drilling or cutting is a machining. The machining areas are indicated on the DXF drawings. Download the configuration sheets and the DXF drawings from the website Send then back to your SAREL agent indicating your modifications. Essential if ordering to take advantage of the configuration timescale. For any other needs or any other constraints - get in touch with us. SAREL also offers customized solutions to meet your other requirements. Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting Cases enclosures electrical panels 51
49 Steel, stainless steel, and polyester floor standing monobloc enclosures Overview of the floor standing monobloc enclosures Material Steel floor standing monobloc enclosures Name of range Spacial universal Spacial customized Spacial " Spacial EMC Operating environment Inside, industrial environment Sealing IP55 IP55 IP54 Impact resistance IK10 or IK08* IK10 or IK08* IK10 or IK08* IK10 or IK08* Dimensions (mm) H 1000 to 2000 W 600 to 1600 D 300 to 600 H 1200 to 2000 W 600 and 800 D 300 to 600 H 1200 to 2200 W 300 to 1200 D 400 to 1200 Size of range 134 references 3 references Transparent/glazed door option b b b b Combinability b b b b RAL color 7032 and 7035 as required * Glazed door version. ** ** Floor standing monobloc enclosure fitted with plain or transparent front door and rear panel, with or without plain galvanized chassis. Customized floor standing monobloc enclosure, all RAL and NF paints, all cutouts and accessories assembled. Fitted floor standing monobloc enclosure with plain front door. 19 chassis ordered separately. Floor standing monobloc enclosure fitted with plain or transparent front door and rear panel, RAL 7032 paint, with or without plain galvanized chassis. **Ask Us. Cutting and assembly of your accessories in the plant - see the Spacial floor standing monobloc enclosure configurator pages
50 Steel, stainless steel, and polyester floor standing monobloc enclosures Overview of the floor standing monobloc enclosures Material Stainless steel floor standing monobloc enclosures Polyester floor standing monobloc enclosures Name of range Spacial stainless steel Thalassa Operating environment Inside, outside, agri-food, pharmaceutical, Inside, outside, infrastructures environment petrochemical, environment Sealing IP55 IP65 or IP54 Impact resistance IK10 IK10 or IK08* Dimensions (mm) H 1400 to 2000 W 600 to 1600 D 300 to 600 H 500 to 1500 W 500 to 1250 D 320 to 420 Size of range 16 references 592 references Transparent/glazed door option - b Boxes Combinability - b RAL colors - - * Glazed door version. Wallmounting enclosures Example: fitted floor standing monobloc enclosure with plain front door. Example: completely closed floor standing monobloc enclosure with smooth door. Thermal packaging of electrical panels Floor standing monobloc enclosures Floor standing suitable enclosures Cutting and assembly of your accessories in the plant - see the Thalassa floor standing monobloc enclosure configurator pages Technical appendices 53
51 The floor standing monobloc enclosures SAREL floor standing monobloc enclosures offer: Spacial steel floor standing monobloc enclosure The universal floor standing monobloc enclosures b Rigidity and sealing. b Simplicity of implementation, practical. Spacial stainless steel floor standing monobloc enclosures b Sealing. b Robust and durable. b Practical and time-saving. b Compatible with the other ranges. b Sterile. b Corrosion resistant. b Aesthetic. Thalassa polyester floor standing monobloc enclosures b Sealing. b Life span. b Ease. b Selection. 54
52 steel, stainless steel, polyester Spacial floor standing monobloc enclosures The universal steel floor standing monobloc enclosure Select: b Plain door: v With plain chassis: 49 references. v Without plain chassis: 49 references. b Glazed door without plain chassis: 25 references. b Glazed door without plain chassis, RAL 7035: 11 references. Rigidity and sealing b Bifolding profile on front side. b Closure system outside sealed area: v 2 closure points for heights of 1000 and 1400 mm, v 4 closure points for heights of 1600 and 2000 mm, Simplicity of implementation b Slide rails with perforations 25 mm apart enable the depth adjustment of material support chassis. Boxes Wallmounting enclosures Spacial stainless steel floor standing monobloc enclosures Sealing b IP55 (EN 60529) protection level: complete protection against dust and water spray. b 3 point lock. b Canopy (optional): v Cable gland plate with a neoprene seal. Robust and durable b External mechanical impact resistance: IK10 according to EN b Three fully stainless steel hinges. b Door reinforcement frame. Practical and time-saving b Stainless steel plinth for cable entry b Reversible door, 120 opening. b Slide rails with perforations 25 mm apart. b Perforated reinforcement frame makes it easy to assemble accessories on the door. Floor standing monobloc enclosures Floor standing suitable enclosures Thalassa polyester floor standing monobloc enclosures Sealing b IP65 for the fully closed floor standing monobloc enclosure. b IP54 for any other version. b Closure system outside sealed area. Life span b Glassfiber-reinforced polyester, ensuring high rigidity and resistance to external impacts, necessary for installation at an urban site. Thermal packaging of electrical panels Select b 40 dimensions. b 4 architecture versions. b 3 types of doors. Technical appendices 55
53 Steel, stainless steel, and polyester floor standing monobloc enclosures Technical descriptions of the floor standing monobloc enclosures Interior installation clean and unclean premises (industrial environment) The response: Spacial floor standing monobloc enclosures Technical features b Sealing: IP55. b Protection against impacts: IK10 or IK08. b Combinable. b Front door: v the double doors are equipped with 2 locking points for the door and inner door, v plain, with reinforcement frame for closets 1400 to 2000 mm tall, with a vertical section for closets 1000 to 1200 mm tall, v transparent in laminated glass and mechanical fixing. b Closure: swiveling handle (insert to be ordered separately). b 4 chassis support brackets. b Supplied with or without plain galvanized chassis according to reference. b Cable gland plate in 2 parts, supplied originally. b Plinths 100 and 200 mm high, optional. b Color RAL 7032 Certifications b UL, CUL, BV, LROS, LCIE. Interior installation, high hygiene and corrosion-resistance requirements (agri-food, pharmaceutical, petrochemical environments) The response: Spacial stainless steel floor standing monobloc enclosures Technical features b Sealing: IP55. b Stainless steel 304L. b Protection against impacts: v IK10 enclosure with plain front door. Brushed finish b Stainless steel 304L floor standing monobloc enclosure, 15/10 mm thick, brushed finish, door thickness 15/10 mm, opening to 120 with fitted reinforcement frame. b 3-point locking, handle with key 1242E, acceptable load 50kg. b Supplied with 4 chassis support brackets. b Cable gland plate in 1 part, supplied originally. Microbeaded finish b Finish making it possible to limit the adherence of any substance, to disinfect, even to sterilize. b Stainless steel quality 304L or 316L, thickness 15/10 mm. b Cross rails with perforations 25 mm apart. b Door with handle lock, painted zamac, key 1242E. b Cable gland plate in 1 part, supplied originally. Interior or exterior installation (infrastructures) The response: Thalassa polyester floor standing monobloc enclosures Technical features b Sealing IP65 in closed version and IP54 in the other versions (self-ventilated with canopy, lower open 60 mm plinth, and self-ventilated with canopy, lower section open, 60 mm type plinth). b Mechanical resistance IK10 and IK08 (glazed-door version). b Temperature protection: 50 C C b Resists the main corrosive chemical and atmospheric agents. b Protection against fire (self-extinguishing at 960 ºC). b Total insulation compatible with class 2. b Reversble door with 180º opening angle for the self-ventilating version with canopy and open lower section, and a 120º opening angle for the other versions. b Select a front door: smooth, glazed, or with anti-posting texture. Possibility of front and rear door. b Locking system: double 5 mm bar insert, other optional. b Locking outside sealed zone, with 2 locking system point up to a 750 mm high, with 4 locks points from 1000 mm. b Possibility of horizontal or vertical coupling and specific assembly in depth. b Direct fitting to floor or through a plinth (optional). b Wall fixing lugs (optional). b Hot press molded polyster floor standing monobloc enclosure, in gray RAL 7032 color. 56
54 Steel, stainless steel, and polyester floor standing monobloc enclosures Define your floor standing monobloc enclosure Environment b Use Internal or External?... b Type of ambient environment: Normal, Saline, Corrosive (which products?)... b Is a canopy required? (Y/N)... b Type of material required (Steel/ Stainless Steel/ Polyester)... Boxes Technical definition b Height (mm)... b Width (mm)... b Depth (mm)... b IP... b IK... b Color RAL... b Type of coating... b Stainless steel finishes: brushed or glass bead blasted... b Type of closure, to be specified... b Visibility: Glazed door, Window... b Type of chassis: Plain, Telequick, Other... Loads to be borne: by enclosure, doors and panels... b Electrical continuity by means of earthing strip, or other (to be specified)... b Cable entry via cable gland plate... b Fitting by fixing Lugs or Direct fixing... b Plinth: specify the height 100 or 200 mm... b Lighting (Y/N)... Customization. See customization help on pages 68 to 69 b Description of machinings (plans, sketches)... b Electrical continuity by means of grounding strip, or other (to be specified)... b Standard accessories fitted... b Specific accessories to be supplied (plans, sketches)... b Application of image: screen print, sticker... Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting enclosures Thermal b Air louvers or Ventilation grilles... b Forced ventilation... b Heating element... b Air-conditioning... b External temperature range... b Internal temperature range... Thermal packaging of electrical panels Logistics b Place of delivery... b Special delivery information?... b Special unloading information?... Technical appendices 57
55 Steel and stainless steel floor standing monobloc enclosures Selection guide for steel and stainless steel floor standing monobloc enclosures External dimensions (mm) No. of front doors Spacial steel floor standing monobloc enclosure IP55 Accessories RAL 7032 RAL 7035 Plain front door Transparent front door Plain front door RAL 7011 plinth Height Width Depth Without chassis With chassis Without chassis Without chassis Height 100 mm Height 200 mm Lifting eye. Lot of 4 parts Door stop Ref Adhesive document pocket Ref. Document pocket Format Material Depth (mm) A4 Plastic A4 Plastic A3 Plastic 35 Door contact O + C Wall fixing lugs Lighting Type France - UTE (16 A plug) Germany - VDE UK - BS (British Standard) voltage 115 V Switzerland - CH 58
56 Steel and stainless steel floor standing monobloc enclosures Selection guide for accessories External dimensions (mm) Spacial stainless steel floor standing monobloc enclosure Brushed finish Plain front door H W D 304L stainless steel 304L stainless steel plinth Height 100 mm Height 200 mm Microbeaded blasted finish Plain front door 304L stainless steel Plain front door 316L stainless steel 304L stainless steel plinth Height 100 mm Height 200 mm Plain galvanized chassis Standard vertical rails Technical vertical rails Boxes Wallmounting enclosures Floor standing monobloc enclosures Floor standing suitable enclosures Thermal packaging of electrical panels Self-piercing screw Flat nuts for standard vertical rails Pivoting nuts for technical vertical rails M6 M M6 M M6 M Notched sliding 1/4 turn nuts Technical appendices 59
57 The Essential Guide SAREL 2.8 SAREL protects your electrical equipment Full services to better integrate your needs The SAREL organization, skills, and resources adapt to your requirements. Customized Solution In order to serve you quickly and to provide solutions adapted to your needs, SAREL has created: b The Configured offer: a standard product upgraded to your needs. From the standard offer, SAREL conducts for you the inplant fitting of the accessories, cut-outs, and paint included in the ranges b The Specific Solution: a product custom developed for you. SAREL creates the enclosure meeting your requirements. Custom dimensions, special colors, custom accessories, thermal integration, casings. Order processing in real time Orders are registered automatically, which makes it possible to process them in real time. Direct access to the EDI system for orders is open to our customers in order to improve turnaround time. Automated logistics The SAREL logistics centers located at Sarre-Union (France) and at Sant Boi (Spain) represent 25,000 m 2 and dedicate a large space to automation. Their flexible organization makes it possible to adapt order processing and shipment depending on orders, within guaranteed deadlines. Selection guides, digital rulers, configurators, and software To help you in the configuration of your enclosures, SAREL provides you with tools on CD-ROM or on its website: b Selection guides for wallmounting enclosures, floor standing monobloc enclosures, floor standing suitable enclosures, and consoles. b Configurators for wallmounting enclosures, floor standing monobloc enclosures, and floor standing suitable enclosures. b Thermal-assessment calculation software: PROclima 4.0. b Digital rulers downloadable at 6
58 Polyester floor standing monobloc enclosures Selection guide for polyester floor standing monobloc enclosures External dimensions (mm) Height Width Depth No. of doors Type of floor standing monobloc enclosure Plain door Glazed door Anti-posting door and rear panel Fully closed IP65 Open lower section type plinth IP54 Self-ventilating with canopy and closed lower section IP54 Self-ventilating with canopy and open lower section IP54 Fully closed IP65 Door opening angle: Self-ventilating with canopy and open lower section IP54 Door contact Ref Adhesive A4 document pocket Ref Door stopper for 120º doors Ref Step slides Floor standing monobloc enclosure depth (mm) No. of doors Adaptor plates Ref. Step slides for closed or open floor standing monobloc enclosures Plate for open floor standing monobloc enclosures M8 inserts Ref Lot of 8 parts Door stopper with 2 positions Ref
59 Polyester floor standing monobloc enclosures Selection guide for accessories Canopy Plinth h = 60 mm Semi-buried plinth h = 900 mm Interior door Chassis Technical vertical rails Boxes Recommended for exterior installations For closed lower section closet. For open lower section floor standing monobloc enclosure. Plain Perforated 19" Steel Insulating Fixed No. of U Pivoting No. of U Polyester cable gland plate for installation in floor standing monobloc enclosures with open lower section For floor standing monobloc enclosure (mm) Depth Width /4 turn nuts M6 M Toggle-nuts M6 M Wallmounting enclosures Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures electrical panels 61
60 Spacial steel and stainless steel floor standing monobloc enclosures Accessories Assembly accessories Canopy for Spacial steel floor standing monobloc enclosure For floor standing monobloc enclosure (mm) Recommended for exterior installations Width Depth Canopy for stainless steel floor standing monobloc enclosure For floor standing monobloc enclosure (mm) Recommended for exterior installations Width Depth Accessories for the base Hygienic stainless steel feet Height (mm) Enables cleaning under the floor standing monobloc enclosures Hygienic feet Castors Castors with locking fitted on plinth Lot of 4 parts. Screw jacks Height Screw jacks Ref Screw jacks Ref Fixed Adjustable Lot of 4 parts. Maximum permissible load per screw jack: 100 kg. Plinth fixing to the ground Plinth fastening to the ground Fixing to the ground Ref M12 62
61 Spacial steel and stainless steel floor standing monobloc enclosures Accessories Cable entry accessories Technical seal Brush for facilitating cable passage Number Plate for cable pass through width (mm) Boxes Door and door accessories Interior door For floor standing monobloc enclosure Height (mm) Width (mm) doors and cannot be fitted on double-door floor standing monobloc enclosures. 180 hinge Not applicable to stainless steel. Cross rails For door width (mm) Door cross rails For door width (mm) Door document lectern For door width (mm) Steel document pocket For door width (mm) Door recentering castors Description Wallmounting enclosures Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures electrical panels Recentering castor Not applicable to stainless steel. 63
62 Spacial steel and stainless steel floor standing monobloc enclosures Accessories Viewing accessories Door window, IP54 altuglas and aluminum frame Door porthole (mm) A B C 55 61,5 C A 68 A 25 B 68 B Closure by a No E lock, type 911 B RONIS Locking accessories Locking system for Spacial steel floor standing monobloc enclosure Standard lock Insert shape fitted on adaptor Description mm square mm square mm square mm square with slot mm triangle CNOMO mm triangle mm triangle mm triangle mm triangle mm double bar mm double bar Cylindrical barrel fitted on adaptor Description E key E key key E key E key A key A key A key A key E key A key E key A key A key E key E key Handle and kit Description Spare standard handle Lock without handle Ref. Description Insert shapes Escutcheon plate Description Male 7 mm square insert Female 8 mm square insert mm triangle insert mm triangle insert Double bar Ø 5 mm insert Screwdriver slot insert Closure system for Spacial steel and stainless steel floor standing monobloc enclosure Description* Packaging mm double bar mm male square mm male square mm male square mm male triangle mm male triangle Padlockable 1 * Only on 304L stainless steel floor standing monobloc enclosures. 64
63 Spacial steel and stainless steel floor standing monobloc enclosures Accessories Earthing accessories Earthing braids and earth connections b See enclosures section page 44. Installation accessories Partial plain chassis Height (mm) Width (mm) Telequick grille Enclosure Fixing spacing (mm) Useful surface (dm²) width (mm) Width Height Order 2 plates corresponding to 800 mm width references Possibilities of assembly on perforated plates b Assembly on vertical rails. b The fixing points of the technical vertical rails are still accessible after the perforated plates are fitted. Height of the floor standing Floor standing monobloc enclosure width (mm) Vertical rails monobloc enclosure (mm) (1) (1) Fitting on 4 vertical rails ref (1800 mm) or (2000 mm) This fitting leaves a 90 mm free space between the plates for installing the channels with the supports ref Clip-nuts for fitting on grilles Clip-nuts Thread M M M M6 Lot of 100 parts Boxes Wallmounting enclosures Technical appendices Thermal packaging of Floor standing suitable enclosures Floor standing monobloc enclosures electrical panels 65
64 Spacial steel and stainless steel floor standing monobloc enclosures Accessories Single Universal Brackets for cross rail Ref Lot of 4 parts. To be used to support a 1 row cross rail in depth. Fit vertically in rear of floor standing monobloc enclosure a 1 row cross rail. 1 row cross set of 2 cross Single Universal Floor standing monobloc enclosures width or depth (mm) (2) (2) (2) (2) (2) (2) (1) Uniformly spread over 2 cross rails. (2) Only for vertical fitting. Lot of 4 parts. Load (1) (kg) Top and bottom adjustment rail for fitting uprights For floor standing monobloc enclosure depth (mm) Not applicable to stainless steel. C rail for heavy loads Rail Length (mm) /28 and 64636/38 Sliding 1/4 turn nuts b Clip on C section. 1/4 turn nuts M6 M
65 Spacial steel and stainless steel floor standing monobloc enclosures Accessories Symmetrical, asymmetrical, and combined rails, and nuts for rails Description Asymmetrical, 2 m length Symmetrical (A), length 2 m Symmetrical (B), length 2 m DIN rail, length 2 m perforated Combined rail, length 2 m Sections Combined section Lot of 10 parts and to to Hexagonal head screw b Slotted-head screw with attached washer. Thread hexagonal head slotted screw with attached washer, length (mm) M M M M (1) (1) Without attached washer. Fixings Sliding 1/4 turn nuts b Clip-on on combined section. b Two models available, M3/M4 or M5/M6. 1/4 turn nuts M3/M4 M5/M Lot of 100 parts. Clip-on nuts b Attach on combined sections and symmetrical sections. clip on nuts M4 M5 M Lot of 100 parts. Sliding 1/4 turn nuts b For asymmetrical sections. 1/4 turn sliding nuts M4 M5 M Lot of 100 parts. Order in multiples of 100 parts. Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures Thermal packaging of electrical panels Cable management accessories b See wallmounting enclosures section page 47. Technical appendices 67
66 Steel and stainless steel floor standing monobloc enclosures Configurator for floor standing monobloc enclosures Floor standing monobloc enclosures Spacial configured Send the document to your local SAREL sales office by or fax YOUR CONTACT DETAILS First/last name: Company: Address: Tel.: Fax: QUANTITY OF FLOOR STANDING MONOBLOC ENCLOSURES(S) REFERENCE CATALOGUE DIMENSIONS (mm) H W D see in the table below PLAIN DOOR COLOR SELECTED ACCORDING TO LIST RAL: NF: REINFORCED ANTICORROSION COATING HINGES ON THE LEFT TYPE OF CLOSURE AND/OR CLOSURE HANDLE ESCUTCHEON REF. INSERT Configurable dimensions (mm) LIFTING EYES DIMENSIONS NOT INCLUDING PLINTH (mm) No. of doors H W D PLAIN GALVANIZED CHASSIS SETS OF 2 VERTICAL RAILS TECHNICAL STANDARD LOCK PLINTH PLINTH HEIGHT 100 MM PLINTH HEIGHT 200 MM PAINTED IN THE COLOR OF THE ENCLOSURE 68
67 Steel and stainless steel floor standing monobloc enclosures Configurator for floor standing monobloc enclosures HELP WITH DEFINING MACHININGS For a faster estimate, please indicate your cutouts on the different sides, then fax the drawing to your SAREL sales branch. For producing your configured floor standing monobloc enclosures with cutouts, the DXF drawings are needed. DRILLING RIGHT D ON THE DOOR QTY. FRONT (EXTERIOR DOOR VIEW) W H BELOW / TOP Spacial configured floor standing monobloc enclosure CABLE GLAND PLATE BOTTOM ON THE BODY QTY. LEFT REAR PLAIN GALVANIZED CHASSIS Download the configuration sheets and the DXF drawings from the website Send them back to your local SAREL agent indicating your modifications. Essential if ordering to take advantage of the configuration timescale. For any other needs or any other constraints - get in touch with us. SAREL also offers customized solutions to meet your other requirements. Floor standing monobloc enclosures Wallmounting enclosures Boxes Technical appendices Floor standing suitable enclosures Floor standing monobloc enclosures Thermal packaging of electrical panels 69
68 The Essential Guide SAREL 2.8 SAREL protects your electrical equipment Structured offers to better cover all the needs of the industry, infrastructures, VDI networks and construction markets Industry and infrastructures VDI and electronics networks Construction ENCLOSURES Industrial boxes in steel b Thalassa industrial boxes made from insulating materials b b Spacial 3D steel wallmounting enclosures b b Spacial steel floor standing monobloc enclosures b b Spacial 6000 steel floor standing suitable enclosures b b Thalassa polyester wallmounting enclosures and floor standing monobloc enclosures b b b Man-machine dialogue wallmounting enclosures and control desks b EMC wallmounting enclosures, floor standing monobloc enclosures and floor standing suitable enclosures b Stainless steel floor standing monobloc enclosures, floor standing suitable enclosures, and control desks b b Thermal management systems b b b CaSys VDI network, server, and telecom* wallmounting enclosures and racks b INSTALLATION PRODUCTS AND SYSTEMS* Mureva watertight equipment b Mureva watertight junction boxes b Mureva built-in junction boxes b Mureva watertight modular enclosures b b Conduit and installation accessories b Fixing accessories b b b *Ask Us. 7
69 Polyester floor standing monobloc enclosures Configurator for Thalassa polyester floor standing monobloc enclosures Configured Thalassa polyester floor standing monobloc enclosures Send the document to your local SAREL sales office by or fax YOUR CONTACT DETAILS First/last name: Company: Address: Tel.: Fax: QUANTITY OF FLOOR STANDING MONOBLOC ENCLOSURES CATALOGUE DIMENSIONS (mm) OR REFERENCE GLAZED DOOR PLAIN DOOR HINGES ON THE LEFT For 1 door floor standing monobloc enclosure HEIGHT WIDTH DEPTH CHOICE OF ARCHITECTURE (Version) 1 FULLY CLOSED IP65 2 AUTOMATIC VENTILATION WITH CANOPY IP54 3 LOWER PART OPEN OF 60 mm PLINTH TYPE IP54 4 AUTOMATIC VENTILATION WITH CANOPY AND LOWER PART OPEN OF PLINTH TYPE IP54 Choice of standard accessories for the configured offer Also check the red box m for accessories fitted in the plant. AERATOR REF OUTLET GRILL REF REF REF FAN REF REF REF m m m DOOR SWITCH BACK CHASSIS PLAIN PERFORATED BAKELITE INSULATION POLYESTER INSULATION MODULAR CHASSIS FIXED 19 CHASSIS THERMOSTAT REF m m m m m m m STEP SLIDES m DOOR SCHEME CABLE GLAND PLATE m INNER DOOR (fitted) DOOR STOP (fitted) 90º (FOR VERSIONS 1,2,3) 2 POSITIONS (90º AND 120º) LOCK MODIFICATION DETAILS BELOW * PADLOCKING M8 INSERTS (SET OF 8) 70
70 Polyester floor standing monobloc enclosures Configurator for Thalassa polyester floor standing monobloc enclosures * Lock modification VERSION 1 STANDARD FRONT PANEL DOUBLE BAR INSERT CHANGE FOR 7 mm SQUARE 8 mm SQUARE 8 mm TRIANGLE Machinings Configured Thalassa polyester floor standing monobloc enclosure VERSION 1 WITH HANDLE AND DOUBLE BAR INSERT CHANGE OF INSERT PUSH-BUTTON CONTROL 8 mm TRIANGLE LOCK 405 LOCK 1242 ADAPTOR FOR DIN LOCK For a quick calculation, please indicate the total number of machinings required: ON THE BACK ON THE FACES (TOP/BOTTOM/SIDE) ON THE DOOR FOR THE GRILLS, FANS AND AERATORS OTHER MACHININGS VERSION 2, 3, 4 (STANDARD) HANDLE AND DOUBLE BAR INSERT NB: Each drilling or cutting is a machining. The machining areas are indicated on the dxf drawings. Download the configuration sheets and the DXF drawings from the website Send then back to your local SAREL agent indicating your modifications. Essential if ordering to take advantage of the configured leadtime. For any other needs or any other constraints - get in touch with us. SAREL also offers customized solutions to meet your other requirements. Floor standing monobloc enclosures Wallmounting enclosures Boxes Technical appendices Floor standing suitable enclosures Floor standing monobloc enclosures Thermal packaging of electrical panels 71
71 Spacial 6000 steel and stainless steel floor standing suitable enclosures Overview of the floor standing suitable enclosures Material Criteria / name of range Spacial 6000 steel floor standing suitable enclosures Floor standing suitable enclosure fitted with front door Floor standing suitable enclosure fitted with front and rear door Floor standing suitable enclosure in kit Operating environment Inside, industrial environment Sealing IP55 IP55 IP55 Impact resistance IK10 - IK08* IK10 - IK08* IK10 - IK08* IK10 - IK08* Dimensions (mm) H 1600 to 2200 W 300 to 1600 D 400 to 800 H 1200 to 2200 W 600 to 1200 D 400 to 800 H 1200 to 2200 W 300 to 1600 D 400 to 800 Size of range 165 references 76 references - - Transparent door option b b b - Combinability b b b b RAL color 7032 and as required * Glazed door version. Customized floor standing suitable enclosure Floor standing suitable enclosure fitted with plain or transparent front door and rear panel, RAL 7032 gray paint, with or without plain galvanized chassis. Floor standing suitable enclosure fitted with plain or transparent front door and rear panel, RAL 7032 gray paint. All component parts of the floor standing suitable enclosure are separately controlled. Customized floor standing suitable enclosure, all RAL and NF paints, all cuttings. Material Spacial 6000 stainless steel floor standing suitable enclosures Criteria / name of range Combinable floor standing suitable enclosure Monobloc PC rack Operating environment Inside, outside, agri-food, pharmaceutical, petrochemical, etc. environment Sealing IP55 IP55 Impact resistance IK10 IK10 - IK08* Dimensions (mm) H 1800 to 2000 W 600 to 1200 D 400 to 600 H 1600 to 1800 W 600 D 600 to 800 Size of range 8 references 4 references Transparent door option - - Combinability b b Finishes Brushed Microbeaded (made to order) Microbeaded * Glazed door version. Combinable floor standing monobloc enclosures made on request in all sizes in 304L or 316L stainless steels, 15/10 mm thickness and microbeaded finish. The monobloc stainless steel PC racks are specially designed to protect the computer hardware installed in corrosive or damp environments requiring washing or exposed to liquid sprays. 72
72 Spacial 6000 steel and stainless steel floor standing suitable enclosures Overview of the floor standing suitable enclosures Material Spacial 6000 steel floor standing suitable enclosures Criteria / name of range PC rack Floor standing suitable enclosure compartmentalized Operating environment Inside, industrial environment 19" rack EMC floor standing suitable enclosure Sealing IP55 IP55 IP55 IP54 Impact resistance IK10 - IK08* IK10 - IK08* IK10 - IK08* IK10 - IK08* Dimensions (mm) H 1600 to 1800 W 600 D 600 to 800 H 1800 to 2000 W 600 to 800 D 600 to 800 H 1200 to 2200 W 600 to 800 D 400 to 800 H 1800 to 2000 W 800 D 400 to 600 Size of range 4 references 8 references - 4 references Transparent door option b - b - Combinability b b b b RAL color * Glazed door version. Floor standing monobloc enclosures Wallmounting enclosures Boxes The PC rack is designed to protect the computer hardware in an industrial environment, RAL 7032 gray paint. The compartmentalized floor standing suitable enclosure separates the work areas by limiting their access, RAL 7032 gray paint. 19" rack, with 19" fixed chassis, fully or partially pivoting, RAL 7032 gray paint. EMC (electromagnetic compatibility) floor standing suitable enclosure, RAL 7032 gray paint. Floor standing suitable enclosures Thermal packaging of electrical panels Cutting and assembly of your accessories in the plant - see the Spacial 6000 floor standing suitable enclosures configurator pages Technical appendices 73
73 The floor standing suitable enclosures SAREL floor standing suitable enclosures offer: Spacial 6000 steel floor standing suitable enclosures b Robust. b Ergonomics. b Practical. b Simplified order. Spacial stainless steel enclosure, IP55 b Sealing. b Robust and durable. b Material and finish. b Practical and time-saving. b Sterile. b Easy to clean. b Corrosion resistant. b Aesthetic. 74
74 steel, stainless steel Spacial 6000 floor standing suitable steel enclosures Spacial stainless steel floor standing suitable enclosure, IP55 Robustness b The combinable Spacial 6000 rack is made from 4 uprights with a triangular profile for great rigidity, with perforations 25 mm apart for assembly of accessories, along with 2 perforated frames top and bottom, which also have perforations 25 mm apart. b Assembled using screws and centering pin. It enables a combination of several floor standing suitable enclosures side by side and/or back to back. b The framework profiles are made of painted galvanized steel to ensure corrosion resistance. Ergonomics b Rapid change of the direction of door opening, pivoting handle locking system combined with a large range of inserts. b Increased accessibility for fitting of accessories. Framework upright locators 100 mm apart makes it easy to position accessories. Practical b Large range of sizes and accessories. Simplified order b With the models listed. Sealing b IP55 (IEC 60529) degree of protection: complete protection against dust and water spray. b 3 point closure. Robust and durable b External mechanical impact resistance: IK10 according to EN b 3 fully stainless steel hinges. b Door reinforcement frame. Material and finishes b brushed 304L Practical and time-saving b Stainless steel plinth: cable entry made easy. b Reversible door. b Padlockable lock with a key or insert shape. b 1242E key as standard. b Slide rails with perforations 25 mm apart. b Perforated reinforcement frame makes it easy to assemble accessories on the door. Floor standing monobloc enclosures Wallmounting enclosures Boxes Technical appendices Thermal packaging of Floor standing suitable enclosures electrical panels 75
75 Spacial 6000 steel and stainless steel floor standing suitable enclosures Technical descriptions of the Spacial 6000 floor standing suitable enclosures Inside, industrial environment The response: Spacial 6000 steel floor standing suitable enclosures Technical features b Framework: lower and upper frames, set of 4 uprights, b Front door: v plain with door reinforcement frame (frame on door from 500 mm width), v transparent in Securit glass and mechanical fixing. b The double doors are overlapping. b Screwed rear panel. b Removable top. b Universal locking system with pivoting handle (insert to be ordered separately). b 4 chassis fixing brackets. b Supplied with or without plain galvanized chassis according to reference. b 2 chassis supports that make it easy to fit the plain chassis. b Supplied originally with floor standing suitable enclosures fitted with plain chassis. b Options: v side panels v plinth heights 100 and 200 mm. Certifications b BV, CUL, DNV, UL, LCIE. Inside, outside, agri-food, pharmaceutical, petrochemical, environment The response: Spacial 6000 stainless steel floor standing suitable enclosures Technical features b Plain framework (not removable) comprising the rear face, top and bottom, all monobloc. b Plain door fitted with: v a perforated reinforcement frame, v a cremone lock in painted zamac with a 1242E key (405E, 455E, 6.5 mm triangle or 5 mm double bar on request), v a glued polyurethane joint 22 6, v stainless steel hinges. b Key or insert to be specified when ordering. b Cable gland plate in one part. b Four chassis fixing brackets. b Options: v plinths 100 and 200 mm high, v hygienic feet 100 and 200 mm high, v cable gland plate with a foam seal, v painted zamac handle with double bar or triangle key. 76
76 Spacial 6000 steel and stainless steel floor standing suitable enclosures Define your floor standing suitable enclosure Environment b Use Internal or External?... b Type of ambient environment: Normal, Saline, Corrosive (which products?)... b Is a canopy required? (Y/N)... b Type of material required (Steel/ Stainless Steel)... Technical definition b Height (mm)... b Width (mm)... b Depth (mm)... b IP... b IK... b Color RAL... b Type of coating... b Stainless steel finishes: brushed or microbeaded... b Type of lock, to be specified... b Visibility: Glazed door, Window... b Type of lock: Plain, Telequick, Other... b Loads to be borne: by enclosure, doors and panels... b Electrical continuity by means of grounding strip, or other (to be specified)... b Cable entry via cable gland plate... b Fitting by fixing Lugs or Direct fixing... b Plinth: specify the height 100 or 200 mm... b Lighting (Y/N)... Customization. See customization help on pages 92 to 94 b Description of machinings (plans, sketches)... b Electrical continuity by means of grounding strip, or other (to be specified)... b Standard accessories fitted... b Specific accessories to be supplied (plans, sketches)... b Application of image: screen print, sticker... Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures Thermal b Air louvers or Ventilation grills... b Forced ventilation... b Resistance heater... b Air-conditioning... b External temperature range... b Internal temperature range... Thermal packaging of electrical panels Logistics b Place of delivery... b Special delivery information?... b Special unloading information?... Technical appendices 77
77 Spacial 6000 steel and stainless steel floor standing suitable enclosures Selection guide for fitted steel floor standing suitable enclosures External dimensions (mm) No. of front doors H W D Plain front door without chassis Spacial 6000 steel floor standing suitable enclosure IP55 RAL 7032 Floor standing suitable enclosure Side RAL 7035 Floor standing Side RAL 7022 plinths with rear panel panels suitable panels enclosure with rear panel Glazed front door without chassis Plain front door with chassis Plain front door without chassis Height (mm) Cable gland plate part 2 parts 3 parts (1) Combination of 2 x 800 mm wide floor standing suitable enclosures. Door stop Ref Lifting eyes. Lot of 4 parts Lifting bracket Standard steel coupling kit Ref. steel Ref. stainless steel Adhesive document pocket Ref. Document pocket Format Material Depth (mm) A4 Plastic A4 Plastic A3 Plastic 35 78
78 Spacial 6000 steel and stainless steel floor standing suitable enclosures Selection guide for fitted stainless steel floor standing suitable enclosures External dimensions (mm) Spacial L stainless steel floor standing suitable enclosure IP55 Plain galvanized chassis Plain intermediate chassis Standard vertical rails Floor standing suitable enclosure Side panels 316L stainless steel microbeaded plinth 304L stainless steel plinth with rear panel and plain 304L H W D stainless steel Height (mm) Height (mm) door Brushed Brushed without chassis Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures Thermal packaging of electrical panels Door contact O + C Lighting Type France - UTE (16 A plug) Germany - VDE UK - BS (British Standard) voltage 115 V Switzerland - CH Flat nuts for standard vertical rails M6 M Self-piercing screw Pivoting nuts for technical vertical rails M6 M Technical appendices 79
79 The Essential Guide SAREL 2.8 Configured and specific The configured offer, a standard product upgraded to your needs From our standard offer, we conduct for you the in-plant fitting of the accessories, cut-outs, and paint included in our range. the MOST SAREL for the standard offer b Large dimensional range. b Large range of functional accessories. b Without feasibility study. b Short and guaranteed turnaround times. How to do it? Select the accessories from our catalogues, refer to our definition files or contact your SAREL correspondant. Save time by creating your cutouts and fittings using our DXF drawings, downloadable on our website: Wallmounting enclosure cutouts and in-plant fitting of the most common accessories 8
80 Spacial 6000 floor standing suitable enclosures Floor standing suitable enclosures in kit Composition For the manufacture of your floor standing suitable enclosure, you can order separately: b For the framework: v the lower and upper frames with the top, v a set of 4 uprights. b For the casing: v the rear panel, v a plain single or double door, in sheet steel 15/10 mm or 20/10 mm thick depending on the reference, v a set of side panels, v a transparent single or double door, in glued Securit glass. In this version, two paint colors are offered: v RAL 7032 gray, v a RAL 7011 black trim. b Optional extras: v a 100 or 200 mm high plinth, v a cable gland plate in 1, 2 or 3 parts, v all floor standing suitable enclosure accessories, for hoisting and handling, for door fittings, etc., v all assembly fittings, v all modular distribution accessories. Nb: in the absence of a front door and rear panel, it is essential to order the single supports, ref to fit the side panels (see pages 78-79). Certifications b BV, CUL, DNV, UL, LCIE. 80
81 Spacial 6000 floor standing suitable enclosures Floor standing suitable enclosures in kit Benefits of the kit formula In addition to the standard offer, the kit formula lends itself to all combinations. Fixing the 4 uprights to the lower and upper frames. Attachment of the rear panel to the self-centering hanger and screwing device. Fitting the door by fixing with studs and hinges. Detailed view of the selfcentering hanger for the side panels. Floor standing monobloc enclosures Wallmounting enclosures Boxes Availability and ease of transport. Reduced volume of stock. Framework assembly in a quarter of an hour. Technical appendices Thermal packaging of Floor standing suitable enclosures electrical panels 81
82 Spacial 6000 floor standing suitable enclosures Selection guide for floor standing suitable enclosures in kit and casing accessories External dimensions Framework Casing (mm) Lower frame Set of 4 Screwed rear Plain door (1) Set of 2 side Upper frame and top uprights panel Single Double panels H W D 20/10 15/10 20/10 15/ (1) Door supplied with lock, hinges and striking plates. 82
83 Spacial 6000 floor standing suitable enclosures Selection guide for floor standing suitable enclosures in kit and casing accessories Casing RAL 7022 plinths Cable gland plate Plain Transparent door (1) galvanized chassis RAL 7032 Securit glass Height (mm) 1 part 2 parts 3 parts Single Double 100 mm 200 mm Accessories for assembly Liftings eyes Lot of 4 parts Locks and inserts Door accessories Accessories for assembly Ventilation Floor standing monobloc enclosures Wallmounting enclosures Boxes Technical appendices Thermal packaging of Floor standing suitable enclosures electrical panels 83
84 Spacial 6000 steel and stainless steel floor standing suitable enclosures Accessories Top accessories Canopy for stainless steel floor standing suitable enclosure 304L Dimensions (mm) Width Depth Top trim Canopy for Spacial 6000 steel floor standing suitable enclosure Width External dimensions (mm) Installation of Spacial floor standing suitable enclosures outside is not recommended Width Depth Coupling accessories Partition panels For floor standing suitable enclosure (mm) Height Depth
85 Spacial 6000 steel floor standing suitable enclosures Accessories Accessories for the base Castors Castors with locking fitted on plinth Screw jacks Ref Screw jacks Ref Front parts Side parts Side parts Front parts Lot of 4 parts. Screw jacks Height Fixed Adjustable Lot of 4 parts. Maximum permissible load per screw jack: 100 kg. Plinth for a group of floor standing suitable enclosures Possible width of assembled floor standing monobloc enclosures (mm) Total width Unit widths Front parts Total width of assembled floor standing monobloc enclosures (1) (mm) Height of plinth (mm) (1) See the list of various possible widths for the floor standing monobloc enclosures. Side parts Depth of assembled floor standing monobloc enclosures (mm) Strengthens the rigidity of the unit Height of plinth (1) (mm) / / / /200 (1) To make a 200 mm high plinth, it is necessary to order a 200 mm high front part and 2 sets of 100 mm high side parts. Accessories for the base Screw jacks, castors b See floor standing monobloc enclosure section page 62. Plinth fixing to the ground b See floor standing monobloc enclosure section page 62. Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures Thermal packaging of electrical panels Technical appendices 85
86 Spacial 6000 steel and stainless steel floor standing suitable enclosures Accessories Cable entry accessories Technical joint (not applicable to stainless steel) Makes it easy to feed through cables of different sizes Width (mm) Floor standing suitable enclosure Joint Lower cross rail for cable guide Floor standing suitable enclosure width (mm) Cable gland, cable gland plates without connector IP65 b See wallmounting enclosures section page 40. Doors and door accessories Inner door for floor standing suitable enclosure For floor standing suitable enclosure (mm) Height Width b Possible depth adjustment in 25 mm steps, min distance between doors: 50 mm. b Closure with 2 locks, 8 mm triangle, other locks see small escutcheon plates. 180 hinges (not applicable to stainless steel) b Set of hinges. b Enable 180 door opening. b Fixings supplied. b Permissible load on the door: 60 kg. Accessories b Door cross rail. b Door document lectern. b Door scheme. b Door recentering castors. b See floor standing monobloc enclosure section page 63. Ref. Description hinges Viewing accessories Door window, IP54 altuglas and aluminum frame b See floor standing monobloc enclosure section page
87 Spacial 6000 steel and stainless steel floor standing suitable enclosures Accessories Locking accessories Locking system for Spacial 6000 steel floor standing suitable enclosure Standard lock Insert shape fitted on adaptor Description mm square mm square mm square mm square with slot mm triangle CNOMO mm triangle mm triangle mm triangle mm triangle mm double bar mm double bar Handle and kit Description Spare standard handle Lock without handle Ref. Description Escutcheon plate Insert shapes Description Male 7 mm square insert Female 8 mm square insert mm triangle insert mm triangle insert Double bar Ø 5 mm insert Screwdriver slot insert Locking system for stainless steel floor standing suitable enclosure Earthing accessories Earth braids and earth connections b See wallmounting enclosures section page 44. Cylindrical barrel fitted on adaptor Description E key E key key E key E key A key A key A key A key E key A key E key A key A key E key E key Description* Packaging mm double bar mm male square mm male square mm male square mm male triangle mm male triangle Padlockable 1 * Only on 304L stainless steel floor standing monobloc enclosure. Floor standing monobloc enclosures Wallmounting enclosures Boxes Technical appendices Thermal packaging of Floor standing suitable enclosures electrical panels 87
88 Spacial 6000 steel and stainless steel floor standing suitable enclosures Accessories Installation accessories Partial plain chassis Height (mm) Width (mm) Plain chassis support For floor standing suitable enclosure depth (mm) b Set of 2 chassis supports. b Authorizes loads up to 500 kg. b Makes it easy to position the plain chassis assembly and enables it to be slid easily to the back of the floor standing suitable enclosure. b Fixes onto the lower frame of the framework. b Supplied originally with floor standing suitable enclosures fitted with chassis. Fixing brackets b Kit with 4 fixing brackets. b Depth adjustable in 25 mm steps. set of 4 brackets (1) (1) For 1200 and 1600 mm widths, order an additional kit, ref to assemble 2 x 600 and 800 mm chassis respectively. Telequick grille Floor standing monobloc enclosure width (mm) Fixing spacing (mm) Useful surface (dm²) Width Height Order 2 plates corresponding to 800 mm width references 88
89 Spacial 6000 steel and stainless steel floor standing suitable enclosures Accessories Possibilities of fitting perforated plates, fitting direct on framework b In all cases, the first mounting hole on the framework is not used. b The upper plate must be fixed in the second hole, 80 mm from the upper frame. b Place the following plates one next to the other. Height of the floor standing suitable enclosure (mm) Height of the floor standing suitable enclosure (mm) Possibilities of assembly on vertical rails b The fixing points of the technical vertical rails are still accessible after the perforated plates are fitted. Width of the floor standing suitable enclosure (mm) Technical vertical rails (1) (1) Fitting on 4 vertical rails. Single Width of the floor standing suitable enclosure (mm) Universal Clip-nuts for fitting on grilles Clip-nuts Thread M M M M6 Perforated cross rails 2 rows set of 2 cross rails Single Universal Floor standing suitable enclosure width / depth (mm) (1) Uniformly spread over 2 cross rails b Continuity of the drilling axis with the framework. b Perforations receiving the pivoting nuts. Fixing on the framework. b Supplied in 2s with support and fixings. Single Universal Perforated cross rails 1 row set of 2 cross rails Single Universal Floor standing monobloc enclosure width / depth (mm) (2) (2) (2) (2) (2) (2) (1) Uniformly spread over 2 cross rails. (2) Only for vertical fitting. Load (1) (kg) Load (1) kg Floor standing monobloc enclosures Wallmounting enclosures Boxes Technical appendices Thermal packaging of Floor standing suitable enclosures electrical panels 89
90 The Essential Guide SAREL 2.8 Configured and specific The specific offer, a product custom developed for you SAREL creates the enclosure meeting your installation or environmental requirements, using our industrial know-how. Custom dimensions, special colors, custom accessories, thermal integration, casings and a la carte configuration. the MOST SAREL b Solutions based on your needs. b Feasibility study with the help of a dedicated study office. b Quality industrial production. b Guaranteed turnaround times. How to do it? Contact your SAREL correspondant and explain your need. A professional team is at your service to develop your specific solution. Example of specific production 9
91 Spacial 6000 Steel and Stainless Steel Enclosures Accessories Single Universal b Set of 2 cross rails. b Are fixed directly on the framework. Perforated cross rails 3 rows set of 2 cross rails Single Universal Floor standing suitable enclosure width / depth (mm) (1) Uniformly spread over 2 cross rails. Light cross rails Load (1) kg For width or depth (mm) framework door Set of 2 cross rails for heavy loads Not applicable to stainless steel. set of 2 cross Cell depth (mm) Load (kg) rails b Lateral adjustment in 25 mm steps. b Rectangular mm holes enabling adaptation to the spacing of the equipment. b Supplied in 2s with fixings. Symmetrical, asymmetrical and combined rails and nuts for rails b See wallmounting enclosure section pages 45 and 46. Slotted hexagonal head screw with captive washer b See wallmounting enclosure section page 46. Equipment support accessories Fixed shelves Floor standing suitable enclosure Shelf reference Shelf W x D (mm) Width (mm) Depth (mm) Cell depth (mm) 2 cross rails b 2 possibilities for assembly depending on whether the depth of the shelf with respect to the Spacial 6000 floor standing suitable enclosure is: v identical: order 1 shelf (fixing system included), v lower: order 1 shelf and 2 cross rails 1 row. In this case, the shelf is adjustable in terms of depth in 25 mm steps. b Material: steel, RAL 7032 gray paint. b Maximum load: 50 kg uniformly distributed. b Height of ply: 30 mm. b Supplied without handle. 90
92 Spacial 6000 steel and stainless steel floor standing suitable enclosures Accessories Telescopic slide Slides reference Cell depth (mm) b Set of 2 telescopic slides. b A telescopic shelf is fitted using: v 1 fixed shelf, v 2 telescopic slides (fitted directly on the framework). b Material: treated steel. b Maximum load: 50 kg uniformly distributed. b Telescopic slide supplied with fixing accessories. b End of run stop for the slide in closed and open position. Cable management accessories b See wallmounting enclosure section page 47. Fixing supports for cables (fitting on framework) Supports reference Floor standing suitable Angle/support enclosure width / depth (mm) Floor standing monobloc enclosures Wallmounting enclosures Boxes Lower cross rail for cable guide Floor standing suitable enclosure width (mm) Technical appendices Thermal packaging of electrical panels Floor standing suitable enclosures 91
93 Steel floor standing suitable enclosures Spacial 6000 floor standing suitable enclosures configurator Spacial 6000 configured floor standing suitable enclosures Send the document to your local SAREL sales office by or fax YOUR CONTACT DETAILS First/last name: Company: Address: Tel.: Project: Fax: Truck with tailgate: NUMBER OF SETS STANDARD REFERENCE HH FLOOR STANDING SUITABLE ENCLOSURE(S) PER SET TOTAL DIMENSIONS OF THE SET (mm) H W D COLOR CHOICE ACCORDING TO THE LIST REF. REINFORCED ANTICORROSION COATING HOISTING RIGHT SIDE PANEL PLINTH LEFT SIDE PANEL WIDTH (mm) FLOOR STANDING SUITABLE ENCLOSURE HEIGHT 100 (mm) HEIGHT 200 (mm) TYPE INDIVIDUAL OF THE SET SPECIAL COLOR FLOOR STANDING FLOOR STANDING FLOOR STANDING A SUITABLE B SUITABLE SUITABLE C ENCLOSURE ENCLOSURE ENCLOSURE D DESCRIPTION OF THE FRONT DOOR GLAZED RG RG RG RG HINGES R L 180º R L 180º R L 180º R L 180º CLOSURE HANDLE ESCUTCHEON PLATE INSERT REF. REF. REF. REF. REAR DOOR REAR PANEL PO PA DO PA DO PA DO PA HINGES R L 180º R L 180º R L 180º R L 180º CLOSURE HANDLE ESCUTCHEON INSERT REF. REF. REF. REF. PARTITIONS CABLE GLAND PLATE WITHOUT PARTS TECHNICAL GASKET 92
94 Steel floor standing suitable enclosures Spacial 6000 floor standing suitable enclosures configurator PLAIN GALVANIZED CHASSIS INTERMEDIATE CHASSIS VERTICAL RAILS 19" CHASSIS GROUNDING STRIP LIGHTING DOOR SWITCH DOOR STOP WINDOWS REF. REF. REF. REF. FLOOR STANDING SUITABLE A ENCLOSURE FRONT FRONT REF. REAR REAR Configured Spacial 6000 floor standing suitable enclosure DEFINE THE ACCESSORIES REF. REF. REF. REF. FLOOR STANDING SUITABLE B ENCLOSURE FRONT FRONT REF. REAR REAR REF. REF. REF. REF. FLOOR STANDING SUITABLE C ENCLOSURE FRONT FRONT REF. REAR REAR REF. REF. REF. REF. FLOOR STANDING SUITABLE D ENCLOSURE FRONT FRONT REF. REAR REAR Floor standing monobloc enclosures Wallmounting enclosures Boxes DOOR SCHEME GLUED TO THE FRONT REF. REF. REF. REF. DOOR SCHEME SCREWED TO THE FRONT FRONT DOCUMENT LECTERN INNER FRONT DOOR SPECIAL COLOR LOUVERS ANTI-INSECT GRILL HOOD/STAND-OFFS FAN OUTLET GRILL COOLING UNIT REF. QUANTITY REF. QUANTITY REF. QUANTITY REF. DEFINE YOUR THERMAL EQUIPMENT REF. QUANTITY REF. QUANTITY REF. QUANTITY REF. Download the configuration sheets and the DXF drawings from the website Send them back to your local SAREL agency indicating your modifications. Essential if ordering to take advantage of the configured deadline. REF. QUANTITY REF. QUANTITY REF. QUANTITY REF. REF. QUANTITY REF. QUANTITY REF. QUANTITY REF. Technical appendices Thermal packaging of Floor standing suitable enclosures electrical panels 93
95 Steel floor standing suitable enclosures Spacial 6000 floor standing suitable enclosures configurator Configured Spacial 6000 floor standing suitable enclosure DEFINE YOUR MACHININGS SPECIFYING THEIR QUANTITY FLOOR STANDING A SUITABLE ENCLOSURE FLOOR STANDING B SUITABLE ENCLOSURE FLOOR STANDING C SUITABLE ENCLOSURE FLOOR STANDING D SUITABLE ENCLOSURE DRILLINGS DRILLINGS DRILLINGS DRILLINGS ON THE FRONT ON THE FRONT ON THE FRONT ON THE FRONT ON THE FRONT ON THE FRONT ON THE FRONT ON THE FRONT ON THE TOP ON THE TOP ON THE TOP ON THE TOP ON THE CHASSIS ON THE CHASSIS ON THE CHASSIS ON THE CHASSIS ON THE LEFT SIDE PANEL ON THE RIGHT SIDE PANEL Download the configuration sheets and the DXF drawings from the website Send them back to your local SAREL agency indicating your modifications. Essential if ordering to take advantage of the configured deadline. If you have any other needs or constraints, get in touch with us. SAREL also offers customized solutions to meet your other requirements. 94
96 Human-machine dialog solutions A global system The design of a global SAREL dialog system, combining aesthetics and ergonomics, makes it easy to meet the requirements of the application and to customize it exactly the way the customer envisages. Wallmounting enclosure with articulated tubes Enclosures which meet the requirements of all industrial IT applications. Our floor standing suitable enclosures and control desks are ergonomic, robust and aesthetic and integrate perfectly into all control and supervision rooms. Thermal packaging of electrical panels Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures PC rack Floor standing suitable enclosures Technical appendices 95
97 Human-machine dialog solutions A global system E A 3 5 D Create your solution! 6 B2 B1 C
98 Human-machine dialog solutions Human-machine dialog wallmounting enclosures Examples of configurations Wallmounting enclosure Tube Fixed sub-base Wall fixture with articulation Straight rotating connector Horizontal tube joint Fixed bracket Rotating fixture on enclosure Right-angled rotating fixture on wallmounting enclosure Tiltable fixture on wallmounting enclosure A ceiling B1 floor B2 floor C on frame D wall E wall Tube section 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm H W D (mm) Tube section 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm Length (m) Tube section 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm Fixture on support Fixed sub-base Wall fixture with articulation Straight rotating connector Choice of models depending on load and cantilever Without articulated joint kg Tube section 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm Connection parts Horizontal tubes joint Fixed bracket Tube section 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm 50 mm 80 mm Fixture on wallmounting enclosure Rotating fixture on wallmounting enclosure Right-angled rotating fixture on wallmounting enclosure Tiltable fixture on wallmounting enclosure kg 150 With articulated joint 80 Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures Thermal packaging of electrical panels Technical appendices l (mm) l (mm)
99 Human-machine dialog solutions Spacial 6000 PC racks with references Composition b Framework. b Partial front doors. b Plain rear door. v 5 mm double bar closure. v Fitted with 6 welded studs for assembling a door reinforcement frame. b Removable top, internal locking. b Removable side panels, internal locking. b 2-part cable gland plate. b Protection index: IP55 (IP40 with the keyboard drawer open). Monitor/screen compartment b Non-reflective glazed door designed to view screens: v 14" as standard. v 17" by partially removing the silk screen. b Height adjustable monitor support; maximum weight of 40 kg. CPU compartment b For PC rack 1800 mm high. Keyboard and mouse compartment b Light pressure on the drawer releases the keyboard shelf to move forwards. b The mouse shelf, fitted with a pad, is located under the keyboard and can slide out to either side for left or right handed users. Printer compartment b As an option, a printer support shelf is available in A3 or A4 formats; get in touch with your local agent. Locking system b The various compartments are supplied with an escutcheon and 5 mm double insert closure system as standard. b Other locks available on request. PC racks External dimensions (mm) PC rack Number of front Plinths (1) RAL 7022 Height Width Depth references compartments 100 mm 200 mm (2) (2) (1) Plinth to be ordered separately. (2) No CPU compartment. 98
100 Human-machine dialog solutions Spacial steel and stainless steel control desk Material Criteria / name of range Spacial steel and stainless steel control desk Monobloc control desk without console The Spacial IP55 control desks range offers all the features required to create a control station that meets industrial and infrastructure needs. A monobloc range, with or without console, and a modular range, provide solutions for every application. They are easy to set up and compatible with dialog components. They ensure the safety and protection of control devices. With a large range of sizes, they fulfill the most demanding user expectations. Monobloc control desk with console Modular control desk Spacial stainless steel control desk Operating environment Inside, industrial environment Inside, outside, agri-food, pharmaceutical environment Sealing IP55 IP55 IP55 IP55 Impact resistance IK10 IK10 IK10 IK10 Dimensions (mm) H 1000 W 600 to 1200 D 400 H 1400 W 800 to 1600 D 400 to 600 H 1000 W 600 to 1200 D 500 H 1000 W 600 to 1200 D 500 Size of range 4 references 8 references 4 references 4 references Transparent door option b b b b Combinability b b b b RAL color as required Floor standing monobloc enclosures Wallmounting enclosures Boxes Monobloc control desks with fixed rear panel. Control desks with console and rear door. Modular control desks with removable rear panel. One or more consoles can be combined. Modular control desks with detachable rear panel. One or more consoles can be combined. Technical appendices Thermal packaging of electrical panels Floor standing suitable enclosures 99
101 Wallmounting enclosures, floor-standing monobloc enclosures and control desks Special production Wallmounting enclosures, floor standing monobloc enclosures or control desks can be specially made on request to meet your own specific requirements. b Made of electrogalvanized 304L or 316L stainless steel sheets, up to 3 mm thick. b Prototype, small or large series production. b Fast quotation on request from your local SAREL agency. Pressurized wallmounting enclosure Floor standing monobloc enclosure for tropical environments Test desk Stainless steel telecommunications floor standing monobloc enclosure Marine floor standing monobloc enclosure Control desk 100
102 Thermal Guarantee the continuity of your processes! ClimaSys offers you an end to breakdowns linked to thermal constraints! Our solutions enable you to adapt to three constraints: Cool To lower the temperature inside the enclosure, you can: b Increase the size of an enclosure: v the space inside an enclosure enables air circulation to be encouraged and the enclosure to be cooled. b Aerate: v the aeration louvers and the top stand-offs enable the intake of fresh air into the enclosure (if the air outside is cooler than the air inside). b Circulate: v the circulation fans, the top hoods and the circulation units enable circulation of the air inside the enclosure and forcing of the air flow. b Ventilate and cool with air-air exchangers: v the fans enable cool air to be taken in with one or two air outlet grills at a flow rate calculated depending on your environment and your equipment, and warm air to be discharged. Floor standing monobloc enclosures Wallmounting enclosures Boxes b Air-condition with air-water exchangers or a cooling unit: v when the outside temperature is higher than the inside temperature. For cooling, there is only one solution: air-conditioning. Floor standing suitable enclosures Heat When it is cold, to maintain an inside temperature which does not affect the performance of your equipment. The resistance heaters controlled by thermostats enable a constant temperature to be maintained. Dry In damp environments, or when the temperature difference causes condensation, a resistance heater must be installed with a hygrostat to avoid the process stopping. Thermal packaging of electrical panels Adapting to the environment: b Contact with the public: anti-vandalism kit b Electromagnetic environments: EMC kit b Rain, cleaning: aluzinc painted cover IP55 b Decontamination, sterilization, cleaning: stainless steel cover IP55 b Presence of insects, oil, dust: special filters Technical appendices 101
103 Thermal Natural ventilation Natural ventilation Natural ventilation ensures air circulation in the enclosure. It enables hot spots to be avoided and thus to guarantee the lifetime of the components. Where enclosures are exposed to rapid variations of external temperature, there are no more problems with condensation on the internal walls. Stand-offs for Spacial 6000 floor standing suitable enclosure Ref IP stand-off 23 Take care: not to be fitted with lifting eyes. Metal ventilation louvers (IP23) Ref , 21410, RAL 7032 louver reference RAL 7035 louver reference Dimensions Louver length IP mm 70 mm mm 100 mm mm 180 mm Top hood without a fan (IP54) b Lot of 4 top stand-offs; raises the top by 14 mm, only for Spacial 6000 floor standing suitable enclosures. b Hood in steel sheet, structured polyester base paint, RAL 7032 gray color. b These 2 solutions are to be combined with fitting ventilation louvers. b Hood with fan, see general catalogue (ref ). Description IP hood 54 Spare filter for top hood Description Retention capacity Filtration capacity (1) filter 500 g/m 2 G4 (1) According to the EN 779 standard. Ref Ref Plastic ventilation louvers b Four models available according to the IP index. Louvers reference Drilling Ø (mm) IP Ref / 44 (1) Ref (1) According to assembly, in the Thalassa polyester wallmounting enclosure. Anti-insect filters Anti-insect filters b Three models according to dimensions. b Material: 304L stainless steel wire Ø 0.32 mm braided, mesh 1.07 mm, thickness 0.6 mm. b These grills are to be placed between the enclosure and the ventilation louver. b Reinforced sealing: IP33. b Mass: 0.8 kg/m. Ref. Height width (mm) For louver reference
104 Thermal Forced ventilation Rapid choice table for fans and accessories Alternating current (AC) power supply (50 Hz values) Ref Ref Alternating current filter fans Ref Full kit Outlet grilles IP54 2 standard colors: RAL 7032 and RAL 7035 Direct current (DC) filter fans Top extractor Direct current (DC) power supply Good sealing level IP Free flow rate with filter (m 3 /hr) IP Free flow rate with Filter (m 3 /hr) Flow rate with 1 outlet grille (m 3 /hr) Flow rate with 1 outlet grille (m 3 /hr) Voltage (V) Voltage (V) Filter fan ref. RAL 7032 Outlet Filter fan grille ref. ref. RAL RAL Outlet grille ref. RAL 7035 Cut-out size (mm) Floor standing monobloc enclosures Wallmounting enclosures Boxes Floor standing suitable enclosures Thermal packaging of electrical panels Technical appendices Filter fan ref. RAL 7032 Outlet grille ref. RAL 7032 Filter fan ref. RAL 7035 Outlet grille ref. RAL 7035 Cut-out size (mm) Ø included in the full kit / DC DC DC DC DC DC DC DC
105 Thermal Forced ventilation accessories Power connection cable for fans b To enable the connection with the fan motor. Length (mm) Anti-vandalism kit b Tamperproof screw kit for outlet grille or filter fan. b Prevents inopportune openings. Dimensions minor ent. (mm) RAL Accessories for severe atmospheres (take care, the flow rates may be reduced by the addition of these accessories) Cut size (mm) Standard filter ref. Greasy atmosphere filter kit ref. IP55 damp atmosphere filter kit ref. Anti-insect grille kit ref. EMC kit for filter fans RAL 7032 EMC kit for outlet grilles RAL Sealing kit IP55 b Protective cover against water spray. b Fitted directly onto the fans and the filters and enables their degree of sealing to be raised to IP55. b Made of stainless steel and aluzinc. b To equip a fan and a grill, order 1 kit for the fan and 1 kit for the grill. Aluzinc Stainless steel External Cut size (mm) Kit reference Replacement filters dimensions reference (mm) in aluzinc in stainless RAL 7032 RAL 7035 steel
106 Thermal Resistance heaters Resistance heaters Power in W Voltage (V) Type of connection Terminal Cable DC p AC p DC p AC p AC p DC p AC p AC p DC p AC p AC p DC p AC p AC p Resistance heaters with fan Type of connection Power in W Voltage (V) Terminal Cable AC p AC p AC p AC p AC p AC p Fixing accessories Description Lot of 5 contact studs Lot of 5 contact studs and DIN rail Floor standing monobloc enclosures Wallmounting enclosures Boxes Insulated resistance heaters Power in W Voltage (V) Type of connection Terminal Cable DC p AC p DC p AC p DC p AC p AC p DC p AC p AC p DC p AC p Insulated resistance heaters with fan Floor standing suitable enclosures Thermal packaging of electrical panels Power in W Voltage (V) Type of connection Terminal Cable AC p Thermofans Type of connection Power in W Voltage (V) Terminal Cable / AC p / AC p Technical appendices 105
107 Thermal Control device Temperature control Set point Ref. Power supply Order a resistance heater fixed thermostat adjustable thermostat Rapid choice table for control accessories Contact Max. switching power Precision Hysteresis 5 C (frost free) O AC 250 V, 10 ± 4 C 7 C 10 C O A AC 120 V, 15 C (condensation) O 5 A DC 30 W C O Secure the set point with a fixed thermostat Order a fan fixed thermostat adjustable thermostat 25 C 30 C 35 C C C C C AC 250 V, 10 A AC 120 V, 5 A DC 30 W +60 C ± 4 C 7 C Order a resistance heater and / or a fan double fixed thermostat C O / C AC 250 V, 10 A AC 120 V, 5 A DC 30 W ± 4 C 7 C T <10 C order a resistance heater T >35 C order a fan C C / C ± 4 C 7 C T >35 C order a fan T >45 C order an alarm double adjustable thermostat C O / O ± 4 C 7 C C O / C ± 4 C 7 C T < T1 C order a resistance heater T > T2 C order a fan OC thermostat electronic thermostat C Inverter Opening AC 250 V, 10 A DC 30W Opening AC 250 V, 5 A DC 30 W C V direct O / C Inverter 2 x 8 A - 24 V DC ± 1.5 C 7 C order a resistance heater or a fan ± 2 C 10 C order a resistance heater or a high precision fan Humidity control Order a resistance heater fixed hygrostat adjustable hygrostat 60% RH C AC 250 V, 5 A DC 20 W 35%...95% RH C AC 250 V, 5 A DC 20 W ± 5% 4% RH ± 5% 4% RH Temperature and humidity control Order a resistance heater and / or a fan hygrotherm C and 35%...95% RH Inverter (relay) Opening AC 240 V, 6 A DC 24V, 4A Closure AC 240 V, 8 A DC 24 V, 4 A temp. 2 C humidity 4% RH 106
108 Thermal Exchangers Technical features The benefits of the SAREL range Air-air exchangers b Reliability. b Simplicity. b Total containment of the components in the floor standing monobloc enclosure. b Inside or outside assembly. Top models reference Vertical models reference reference reference External dimensions H W D (mm) Specific power (1) 50 W/K 15 W/K 35 W/K 60 W/K Air flow rate of the external circuit 450 m 3 /hr 200 m 3 /hr 450 m 3 /hr 450 m 3 /hr Air flow rate of the internal circuit 450 m 3 /hr 200 m 3 /hr 450 m 3 /hr 450 m 3 /hr Heat exchange surface 3.3 m m m m 2 Weight of the equipment 19 kg 12 kg 15 kg 35 kg Control yes yes yes yes Type thermostatic thermostatic thermostatic thermostatic Temperature control range C C C C Supply voltage 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz Start-up / rated current 2.1/0.7 A 2.1/0.7 A 2.1/0.7 A 2.1/0.7 A Electrical power input 150 W 150 W 150 W 150 W Noise level 67 db 64 db 64 db 64 db IP on internal/external circuit IP54/IP34 IP54/IP22 IP54/IP22 IP54/IP22 Nature of the fluid air air air air (1) The power in W is obtained by multiplying the specific power by the temperature difference between the inside and outside of the enclosure. Example: for the exchanger ref , for a difference of 10 C, the power is 350 W. Floor standing monobloc enclosures Wallmounting enclosures Boxes The benefits of the SAREL range Air-water exchangers b Economical. b No filter maintenance. b Reliability. b Simplicity. Floor standing suitable enclosures Technical features Top models reference Vertical models reference External dimensions H W D (mm) Cooling capacity A35W l/hr 1800 W 1800 W Maximum water pressure 1 MPa 1 MPa Air flow rate of the external circuit 330 m 3 /hr 330 m 3 /hr Weight of the equipment 26 kg 19 kg Control yes yes Type thermostatic thermostatic Temperature control range C C Supply voltage 230 V - 50/60 Hz 230 V - 50/60 Hz Start-up / rated current 1/0.5 A 1/0.5 A Electrical power input 90 W 90 W Noise level 62 db 62 db Type of alarm dry contact dry contact IP IP54 IP54 Nature of the fluid/max. pressure water/10 bars water/10 bars Thermal packaging of electrical panels Technical appendices 107
109 Thermal Electronically controlled cooling unit Side models Technical features reference reference reference reference External dimensions H W D (mm) Cooling capacity EN 814 A35-A W 1400 W 1400 W 1800 W Cooling capacity EN 814 A50-A W 1120 W 1120 W 1440 W Air flow rate of the internal circuit 450 m 3 /hr 550 m 3 /hr 550 m 3 /hr 650 m 3 /hr Air flow rate of the external circuit 600 m 3 /hr 750 m 3 /hr 750 m 3 /hr 900 m 3 /hr Maximum pressure reached 2.3 MPa 2.3 MPa 2.3 MPa 2.3 MPa Weight of the equipment 47 kg 48 kg 49 kg 51 kg Control yes yes yes yes Type of control electronic electronic electronic electronic Temperature control range C C C C Operating temperature range C C C C Supply voltage 230 V - 50/60 Hz 230 V - 50/60 Hz Three 400/440 V - 50/60 Hz Three 400/440 V - 50/60 Hz Start-up / rated current 15/3.5 A 19.7/4.5 A 12/1.8 A 12/2 A Electrical power input A35-A W 800 W 700 W 900 W Electrical power input A50-A W 1000 W 900 W 1100 W Noise level 67 db 67 db 68 db 68 db Coolant gas/weight HFC R134a / 0.75 kg HFC R134a / 0.8 kg HFC R134a / 0.8 kg HFC R134a / 0.9 kg Type of alarm dry contact and bell dry contact and bell dry contact and bell dry contact and bell Filter on external circuit option option option option IP on internal/external circuit IP54/IP34 IP54/IP34 IP54/IP34 IP54/IP34 Recommended thermal protection (1) 6 A 6 A 4 A 4 A (1) Fuse blowing curve. Top models Technical features reference reference External dimensions H W D (mm) Cooling capacity EN 814 A35-A W 1800 W Cooling capacity EN 814 A50-A W 1440 W Air flow rate of the internal circuit 320 m 3 /hr 400 m 3 /hr Air flow rate of the external circuit 450 m 3 /hr 450 m 3 /hr Maximum pressure reached 2.3 MPa 2.3 MPa Weight of the equipment 48 kg 51 kg Control yes yes Type of control electronic electronic Temperature control range C C Operating temperature range C C Supply voltage 230 V - 50/60 Hz Three 400 V - 50/60 Hz Start-up / rated current 19/4.5 A 12/2 A Electrical power input A35-A W 900 W Electrical power input A50-A W 1100 W Noise level 67 db 67 db Coolant gas/weight HFC R134a / 0.85 kg HFC R134a / 0.9 kg Type of alarm dry contact and bell dry contact and bell Filter on external circuit option option IP on internal/external circuit IP34/IP55 IP34/IP55 Recommended thermal protection (1) 6 A 4 A (1) Fuse blowing curve. 108
110 Thermal Mechanically controlled cooling unit Side models Technical features ref (5) ref ref ref ref ref External dimensions H W D (mm) Cooling capacity EN 814 A35-A35 (1) 240 W 370 W 760 W 1050 W 1650 W 1800 W Cooling capacity EN 814 A50-A35 (1) 170 W 290 W 600 W 840 W 1400 W 1500 W Air flow rate of the internal circuit 160 m 3 /hr 160 m 3 /hr 350 m 3 /hr 350 m 3 /hr 550 m 3 /hr 550 m 3 /hr Air flow rate of the external circuit 620 m 3 /hr 210 m 3 /hr 330 m 3 /hr 510 m 3 /hr 620 m 3 /hr 620 m 3 /hr Maximum pressure reached 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa Weight of the equipment 15 kg 21 kg 33 kg 39 kg 42 kg 46 kg Control yes yes yes yes yes yes Type of control thermostatic thermostatic thermostatic thermostatic thermostatic thermostatic Temperature control range C C C C C C Supply voltage (2) 230 V - 50 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 400/440 V - 50/60 Hz (4) Start-up / rated current 3.5/0.8 A 6/1.6 A 8/2.4 A 11/2.9 A 18/4.6 A 10/2.3 A Electrical power input A35-A W 290 W 380 W 500 W 800 W 1200 W Electrical power input A50-A W 340 W 450 W 650 W 1000 W 1400 W Noise level 58 db 65 db 67 db 67 db 67 db 69 db Coolant gas/weight R134a/0.3 kg R134a/0.3 kg R134a/0.5 kg R134a/0.7 kg R134a/1.0 kg R134a/1.0 kg Type of alarm dry contact dry contact dry contact dry contact dry contact dry contact Filter on external circuit option yes yes yes yes yes IP on internal/external circuit IP54/IP34 IP54/IP34 IP54/IP34 IP54/IP34 IP54/IP34 IP54/IP34 Recommended thermal protection (3) 6 A 3 A 4 A 6 A 3 A 4 A (1) The equipment complies with DIN 3168 standards and the EN 814 European standard. (2) For equipment operating at other voltages and frequencies, please contact us. (3) Fuse blowing curve. (4) Three-phase. (5) Mini air conditioner. Floor standing monobloc enclosures Wallmounting enclosures Boxes Top models Technical features ref ref ref ref ref ref ref External dimensions H W D (mm) Cooling capacity 760 W 1050 W 1460 W 1650 W 1650 W 2450 W 3100 W EN 814 A35-A35 (1) Cooling capacity 600 W 840 W 1180 W 1400 W 1400 W 1960 W 2500 W EN 814 A50-A35 (1) Air flow rate of the internal circuit 350 m 3 /hr 430 m 3 /hr 430 m 3 /hr 550 m 3 /hr 550 m 3 /hr 750 m 3 /hr 750 m 3 /hr Air flow rate of the external circuit 350 m 3 /hr 570 m 3 /hr 570 m 3 /hr 620 m 3 /hr 620 m 3 /hr 1200 m 3 /hr 1200 m 3 /hr Maximum pressure reached 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa 1.8 MPa Weight of the equipment 33 kg 41 kg 45 kg 47 kg 60 kg 65 kg 65 kg Control yes yes yes yes yes yes yes Type of control thermostatic thermostatic thermostatic thermostatic thermostatic thermostatic thermostatic Temperature control range C C C C C C C Operating temperature range C C C C C C C Supply voltage (2) 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 230 V - 50/60 Hz 400/440 V 50/60 Hz 400/440 V 50/60 Hz 400/440 V 50/60 Hz Start-up / rated current 8/2.4 A 11/2.9 A 11/2.9 A 18/4.6 A 10/2.3 A 14.5/2.8 A 14.5/3.4 A Electrical power input 380 W 500 W 700 W 800 W 1200 W 1200 W 1500 W A35-A35 Electrical power input 450 W 650 W 900 W 1000 W 1400 W 1500 W 1850 W A50-A35 Noise level 67 db 67 db 67 db 69 db 69 db 69 db 69 db Coolant gas/weight R134a/0.5 kg R134a/0.7 kg R134a/0.850 kg R134a/1 kg R134a/1 kg R134a/1.25 kg R134a/1.25 kg Type of alarm dry contact dry contact dry contact dry contact dry contact dry contact dry contact Filter on external circuit yes yes yes yes yes yes yes IP on internal/external circuit IP55/IP34 IP55/IP34 IP55/IP34 IP55/IP34 IP55/IP34 IP55/IP34 IP55/IP34 Recommended thermal protection (3) 4 A 6 A 6 A 6 A 4 A 6 A 6 A Floor standing suitable enclosures Thermal packaging of electrical panels Technical appendices 109
111 Wallmounting, monobloc and suitable enclosures Common accessories Fixings Description Ø Length (mm) Specific use Clip-nut M Fitting on perforated plates on Telequick grill. M M M Pivoting nut M Fitting on the framework of Spacial 6000 floor M standing suitable enclosures and on technical vertical rails. Serrated 1/4-turn sliding nut M Clippable on the technical vertical rails and on the M serrated C profiles. Standard 1/4-turn sliding nut M Clippable on the technical vertical rails and on the M serrated C profiles. 1/4-turn sliding nut M3 and M4 M5 and M Clippable on combined profiles Clip-nut M Clippable on combined profiles and on symmetrical M cross rails. M /4-turn sliding nut M Fitting on asymmetrical cross rails. M M Flat nut M Fitting on standard vertical rails. M Slotted hexagonal head screw with captive washer M Nut ref M M Nut ref M M Nut ref M M Without captive washer. Self-tapping hexagonal head M For fitting equipment onto the plain chassis. screw M For fitting equipment onto the door reinforcement frame of floor standing monobloc enclosures and suitable enclosures. Insulated head screw M To comply with electrical insulation. 110
112 Wallmounting, monobloc and suitable enclosures Common accessories Cabling accessories Cable duct with cover Dimensions (mm) Maximum capacity: Packaging Width Height number of flexible wires , , b Material: Rigid PVC with side opening slots and perforations on the back; supplied in 2 m linear lengths. b RAL 7030 gray color. b Conforms to VDE 0660/506, DIN standards. b Temperature resistance: C b Fire behavior: V0 material in...compliance with UL 94. b Glow-wire resistance: 960 C according to EN /1. b Maximum flexible wire capacity - H07.V.K 1.5 mm 2 (load factor 0.6): see table above. b Continuity of the vertical plane with the 15 mm deep profiles and the perforated chassis. Duct cover For duct width (mm) , Retention bars Description Retention bars b Separate covers for replacement. b Supplied in 2 meter lengths. b Fixed between 2 duct lamellas using a folding lock, they prevent the cables from falling. b Their length can be cut to adapt to the width of the duct. b Material: impact and flame resistant polystyrene. b Lot of 4 parts. Technical appendices Boxes Wallmounting enclosures Floor standing monobloc enclosures Floor standing suitable enclosures Thermal packaging of electrical panels 111
113 Wallmounting, monobloc and suitable enclosures Common accessories Fixing accessories By screwing, insulated head screw Description insulated head screw M5 10 Lot of 100 parts b M5 10 mm slotted hexagonal head screw. b Compliance with electrical insulation. By clipping, plastic foot Description plastic foot Lot of 20 parts b Clippable on a perforated plate or on a 35 mm profile. b Comprises a lock which fixes the ducts via the mm perforations created in the back. b The 2 functions, clipping and locking, enable great time savings. b Material: black polyamide. Fire behavior: V0 in compliance with UL 94. b Compliance with electrical insulation. On the door, Ø 22 mm duct support Description Ø 22 mm duct support Lot of 10 parts b Fitted on the door of the wallmounting or floor standing monobloc enclosure along with the Ø 22 mm products. b Material: treated steel. On technical vertical rail, duct support Ref. Description duct support b Enables the fitting of ducts on the technical vertical rails, whilst increasing the useful surface of the equipment (up to 20% depending on the width of the duct). b Material: treated steel. Marking accessories Legend-holder Ref. Description Legend-holder Lot of 50 parts b In transparent plastic, clippable on the wings of the ducts. b Paper labels supplied. b Material: polycarbonate. 112
114 Wallmounting, monobloc and suitable enclosures Common accessories Fittings on upright Ref /11275/11276/11277 Metal cable guides Dimensions (mm) Ref. intermediate cableguide support Ref for assembly on framework Dimensions (mm) Guides and fittings on uprights b Fitting on: v 19" uprights (side section), v all the cable support cross rails, v at the back of the 19" shelves, v on the framework uprights, using the intermediate support ref , v plastic material, RAL 7035 gray color, v lot of 10 (guides and support). Metal cable guides b Ø 5 mm steel rod. b Supplied with the fittings (screw, nut, zamak support). b Installation on the 19" chassis. b Lot of 4 parts. Vertical 19" cable guides Fixing on the 19" chassis b Cable guide ref also fixes onto the framework of the Spacial 6000 floor standing suitable enclosure. b Material: nickel steel. b By unit. Cable guide reference No. U Depth (mm) Boxes Wallmounting enclosures ,5 120 Vertical 19" cable guides Ref Ref Ref Ref ,5 106 Lighting accessories Extra flat lighting Type without socket UTE (16 A) b Electronic ignition. b UL (U194V-0). b IP20 - class 1. b 11 W Lumens. b Magnetic fixing possible. b The door lighting is available in three versions: v with movement detector, v with Start/Stop switch, v portable inspection lamp with simple holder, b Low consumption light source: E27 socket, 20 W, V / Hz. b Screw-in or magnetic fixing (sensor and switch), adhesive fixing (portable inspection lamp). b Supplied with a power cable, with a plug and socket (portable inspection lamp version) or with a 2.5 mm 2 screw terminal power supply block (sensor and switch version). b Terminal connection block for series connection of a door switch and a lamp (ref and 21421). b Degree of protection: IP20. b Insulation class II. b Conforms to EN and EN standards. b Compact 11 W, 220 V / 50 Hz neon lamp, with switch and socket. Operates with a door switch ref b Quick fit by magnetic plate or fixing on DIN rail. b Supplied with window protection. b Spare bulb ref for references 21420, and Accessories b Separate power cable ref for references and b Clippable power socket on the 35 mm profile. b Spare bulb ref for references 21420, and Floor standing monobloc enclosures Floor standing suitable enclosures Thermal packaging of electrical panels Description Lighting with sensor Lighting with switch Portable lamp Power cable UTE power socket VDE power socket IMQ power socket Spare bulb Technical appendices 113
115 Your notes 114
116 Technical Appendices 115
117 Technical appendices Thermal's 4 key points Topic 1: What is thermal management? Thermal management is a range of solutions which enable ventilation, aeration, cooling and heating of an enclosure. To establish the solution that suits you best, you need to do a thermal study report. Topic 2: What is a thermal study report? A thermal study report is an analysis of your requirements dependent on: b the environment you put your enclosures into, b the products you use, b your temperature control requirements. If you work in an aggressive ENVIRON- MENT your activity might be JEOPARDIZED! Topic 3: What is the aim of a thermal study report? A thermal study report will enable you to establish what you need to do to avoid breakdowns in your plant, according to the components referred to above. Topic 4: What are the issues? Avoiding breakdowns: Electrical components work properly up to 35 C, and electromechanical components up to 50 C. You must therefore plan a thermal study report to establish which thermal accessory to use. Avoiding the deterioration of components: The enclosure protects the components from mechanical impacts, dust and water and oil sprays, but when the temperature rises, this puts the installations under heavy stress. 116
118 Technical appendices Making your thermal study report Requirements Solution Pages Advantages of the solution Constraints of the solution Circulate Install circulation fans 103 to 104 v Very economical, v No maintenance, v Easy to implement, v IP preserved. v Small quantity of exhaust heat. Boxes Cool Oversize the enclosure v Economical, v No maintenance, v Easy to implement, v IP preserved. v Small quantity of exhaust heat, v More space required. Aeration Ventilation Install ventilation louvers Install fresh air intake fans 102 v Very economical, v No maintenance, v Easy to implement. 103 to 104 v Economical, v Easy to implement, v Large quantity of exhaust heat, v Possible temperature control. v Small quantity of exhaust heat, v Deterioration of the IP (dust). v Regular filter maintenance essential. Wallmounting enclosures Air-air cooling Install an air-air exchanger Install a cooling unit 107 v Easy to implement, v IP preserved at installation, v Series temperature control, v Easy maintenance. 108 v Easy to implement, v Discharges a large quantity of heat (even if the ambient temperature is high), v IP preserved, v Series temperature control. v Regular filter maintenance essential. v Regular filter maintenance essential, v Cannot be used above an ambient temperature of 55 C. Floor standing monobloc enclosures Heat Install an airwater exchanger Install a resistance heater 107 v Easy to implement, v Discharges a large quantity of heat (even if the ambient temperature is high), v IP preserved, v Series temperature control, v No filter to be maintained. 105 v Economical, v Series temperature control. v Needs a water circuit, v Significant consumption if using a municipal water supply. v Energy consumption, v Reduction of useful space. Floor standing suitable enclosures Air-water cooling Install a resistance heater (keeping the temperature above the dew point) 105 v Economical, v Reduction of humidity in the floor standing monobloc enclosure. v Energy consumption, v Reduction of useful space. Thermal packaging of electrical panels Resistance heaters Technical appendices 117
119 Technical appendices Forced ventilation Theoretical calculation Selection guide for fans We have simulated three situations which are most commonly encountered. You have two possibilities: b Follow the 3 steps to establish the solution that suits you manually. b Choose the solution directly and quickly, according to the dissipated power and the dimensions of the enclosure, following the color coding in the tables on the opposite page. The three steps to establish the solution Step 1: calculation of the temperature without a thermal accessory: Ti = Te + ( Pd / S. K ) Ti: internal temperature Step 2: calculation of the power needed: Psys = Pd -[ K.S.( Ts -T e )] in W b Pd = power dissipated by the components b K = heat transfer coefficient: v sheet steel K = 5.5 v polyester K = 3.5 b S = Exchange surface with the air: v Ts = required inside temperature v Te = ambient outside temperature Step 3: calculation of the air flow rate needed: Flow rate = f. Psyst / ( Ts - Te ) in m 3 / hr b f = coefficient linked to the altitude of the location: v altitude 0 to 100 m, f = 3.1 v altitude 250 to 500 m, f = 3.3 v altitude 750 to 1000 m, f = 3.5 Example: Starting hypotheses Product: sheet steel wallmounting enclosure (hence K = 5.5) Dimensions (mm): Sealing: IP66 Location: fixed against a wall Altitude = 50 m (hence f = 3.1) S =1.36 m² K = 5.5 f = 3.1 Ts = 35 C Te = 30 C Pd = 200 W Step 1: calculation of the temperature without a thermal accessory Ti = Te + ( Pd / S. K) = 30 + (200 / ) = 56 C Step 2: calculation of the system power needed to reach Ts = 35 C Psys = Pd [K.S.(Ts T e)] = 200 [ (35 30)] = W Step 3: calculation of the air flow rate needed Flow rate = f. Psyst / (Ts Te) in m 3 / hr = 3.1. Choice will be of a fan Ref along with a grill Ref ; the whole unit gives a flow rate of 153 m 3 /hr, see pages 103 to
120 Technical appendices Forced ventilation Pre-calculated solutions Case No. 1 Sheet steel wallmounting enclosure Starting hypotheses b Product: coated sheet steel wallmounting enclosure (hence K = 5.5 W / m² / C). b Sealing: min. IP54. b Dimensions: see table. b Location: with its back to a wall. b External temperature: Te = 30 C (Delta T = 5). b Required internal temperature: Ts = 35 C (Delta T = 5). Example: P = 100 W Wallmounting enclosure = mm Results: fan ref grill ref Case No. 2 Sheet steel floor standing monobloc enclosure Starting hypotheses b Product: coated sheet steel floor standing monobloc enclosure (hence K = 5.5 W / m² / C). b Sealing: min. IP54. b Dimensions: see table. b Location: with its back to a wall. b External temperature: Te = 30 C (Delta T = 5). b Required internal temperature: Ts = 35 C (Delta T = 5). Dissipated power (W) Dissipated power (W) Dimensions of the floor standing monobloc enclosure H W D (mm) Dimensions of the floor standing monobloc enclosure H W D (mm) flow rate with 1 outlet grill m 3 /hr flow rate with 1 outlet grill m 3 /hr Fan reference Grill Cut (mm) nothing 100 r r no solution * * very high power for small wallmounting enclosure Fan reference Cut (mm) 100 nothing no solution * * very high power for small wallmounting enclosures Grill ref. Floor standing suitable enclosures Floor standing monobloc enclosures Wallmounting enclosures Boxes Case No. 3 Polyester floor standing monobloc enclosure Starting hypotheses b Product: polyester floor standing monobloc enclosure (hence K =3.5 W / m² / C). b Sealing: min. IP54. b Dimensions: see table. b Location: on the floor accessible from all sides and protected from solar radiation. b External temperature: Te = 30 C (Delta T = 5). b Required internal temperature: Ts = 35 C (Delta T = 5). Dissipated power (W) Dimensions of the floor standing monobloc enclosure H W D (mm) flow rate with 1 outlet grill m 3 /hr Fan reference 50 Cut (mm) 75 nothing Grill ref. Thermal packaging of electrical panels Technical appendices 119
121 Technical appendices Calculation and selection support software New PROclima software 4.0 Software for calculating and selecting the thermal accessories needed for enclosures containing electrical or electronic equipment. b Makes the calculations shown on pages 118 to 119, along with the corrected areas, depending on the dimensions of the enclosure and its position with respect to the walls. b Available in CD-ROM format, in four languages: French, English, German and Dutch. b Minimum configuration needed: compatible computer IBM PC 486 SX 33 MHz, with 8 MB of random access memory (RAM), a hard disk with 10 MB of free space, a CD-ROM drive, a monitor and a VGA graphics card ( points). Description PROclima Software Version 4.0 b Recommended configuration: compatible computer IBM PC 486 SX 90 MHz, with 16 MB of random access memory (RAM), a hard disk with 10 MB of free space, a CD-ROM drive, a monitor and an SVGA graphics card ( points). b Operating system: Microsoft DOS version 5.0 or higher, Microsoft Windows version 3.1 or higher, Microsoft Windows NT version or higher. b Software can be downloaded from /services/outils.php, or is available from our local SAREL agency ref Entry of electrical data for the installation Entry of internal and external temperature data for the enclosure Select the thermal management system (fans, exchangers, etc.) View and print the project overview. 120
122 Technical appendices Definition of degrees of protection The advantage: SAREL commits to the IPs after the IK test b The degrees of protection provided by low and medium voltage electrical equipment enclosures (up to 1000 V and 1500 V ) are defined by the IEC or EN (IP) and IEC or EN (IK) standards. b To indicate the degrees of protection: v The IP code is used. The figures indicate the degree of protection provided by the enclosure against access to the dangerous parts and ingress of solid bodies (1 st figure), and against ingress of liquids (2 nd figure), v The IK code is used followed by 2 figures, indicating the degree of protection provided by the enclosure against external mechanical impacts. Boxes IP IK First figure Second figure Protection against solid bodies Protection against liquids Mechanical protection 0 No protection 0 No protection 0 No protection Protected against solid bodies larger 1 than 50 mm 1 (e.g. : accidental hand contact) Protected against 2 solid bodies larger 2 than 12 mm (e.g. : finger) 3 Protected against solid bodies larger 3 than 2.5 mm (tools, wires) Protected against water droplets falling vertically (condensation) Protected against water droplets falling up to 15 from the vertical Protected against rainfall up to 60 from the vertical 4 Protected against 4 Protected against solid bodies larger water spray from than 1 mm (fine any direction tools, small wires) 5 Protected against dust (no harmful 5 deposits) 6 Fully dust-tight 6 Protected against water jets sprayed from any direction Protected against water spray similar to waves 7 Protected against the effects of immersion 7.5 cm cm cm cm cm cm cm cm cm 200 g 200 g 200 g 200 g 200 g 500 g 500 g 1.7 kg 5 kg Impact strength: joules Impact strength: joules Impact strength: joules Impact strength: joules Impact strength: joules Impact strength: joules Impact strength: joules Impact strength: joules Impact strength: joules Wallmounting enclosures Floor standing monobloc enclosures Floor standing suitable enclosures Thermal packaging of electrical panels 8 Protected against the effects of prolonged immersion under pressure cm 10 5 kg Impact strength: joules Technical appendices 121
123 122
124 s Index 123
125 REFERENCES INDEX reference page reference page reference page reference page reference page reference page , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , 79, , 79, , 67, , 67, , 67, , 67, , 67, , 67, , 67, , , 67, , 67, , 67, , 59, , 65, 89, , 65, 89, , 65, 89, , 65, 89, , 58, , 58, 60, , 58, , , , , , ,
126 REFERENCES INDEX reference page reference page reference page reference page reference page reference page , , , , , , , , , , , , , , , , , , , , , , , , , , , , , 38, , 38, , 38, , , , , , , , , , , , , , ,
127 REFERENCES INDEX reference page reference page reference page reference page reference page reference page , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , 61, , , , 65, , 65, , 65, , , , , 79, , 79, , 79, , 79, , 79, , 79, , 79, , 79, , 79, , 79, , 79, , , , , , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , 88, , , 89, , 89, , 89, , 66, , 61, 66, , 66, , 61, 66, , 67, , 67, , 67, , , , , , , , , , , , , , , , , , , 61, 79, , 61, 79, , ,
128 REFERENCES INDEX reference page reference page reference page reference page reference page reference page , , , , , 78, , 78, , 78, 83, , 83, , 78, , 78, , 78, , , 78, , 78, , , , 78, , 78, , 78, , , 78, , , , , , 78, , 78, , 78, 83, , 83, , 78, , 78, , 78, , , 78, , 78, , , , 78, , 78, , 78, , , , , , , , 78, , , , ,
129 REFERENCES INDEX reference page reference page reference page reference page reference page reference page
130 SAREL S.A. 52, route de Phalsbourg BP Sarre-Union Cedex France Tel.: (33) Fax: (33) [email protected] http;// SAREL Unit C, Stirling Court, Stirling Road South Marston Industrial Estate Swindon, Wiltshire SN3 4TQ United Kingdom Tel.: (44) Fax: (44) [email protected] Due to changes in regulations and in materials, the characteristics given for the texts and the images in this document are not binding until confirmed by our technical service. SAREL08MK07en Dep. legal: B
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
Stainless-steel enclosures
Stainless-steel enclosures Spacial S3X Stainless-steel wall-mounting enclosures 5/8 Dimensions 5/11 Selection guide 5/12 Spacial S3EX for potentially explosive atmospheres 5/16 Spacial SMX Stainless-steel
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
Guide to enclosures for potentially explosive atmospheres
Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres The safety of every application, in every environment, thanks to ATEX-certified steel,
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
STB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue
ratiopacpro Overview... 0 Cabinets... 1 Y Desk-top cases Y Wall mounted cases... 2 Accessories for cabinets and wall mounted cases... 3 Climate control... 4 Desk-top cases... 5 06800002 Subracks/ 19" chassis...
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
Knürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724.
Printed board handle A Assembly behind front panels Only use printed board handle in conjunction with printed board retainer A (6087-097) Insertion and extraction function Labelling option B4-2728 Item
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
Data Centre Solutions
Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
PROLINE Go l d Se r i e s. Desk Consoles and Accessories
Modular Enclosure Systems Application PROLINE Gold Series desk consoles are ergonomically designed for use in either a sitting or standing position. Single-access consoles have a front door and solid back.
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
Plaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI
CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI The Company Founded in 1973 by Mr Imes Tinti in association with his son Vanni Tinti. In 1999 the locksmith workshop became a modern industrial company
Type 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
Customized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments
Cannon T4 Modular Data Centres For Outside Deployment & Challenging Environments A high performance, full specification Data Centre, up to Tier 4* resilience, instantly deployable A highly secure Data
K17.12 Door closers K17. Doors 01.09.2013
K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - [email protected] - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor
CNC Tool Storage Solutions
Solutions CNC TOOL STORAGE SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1
Knürr DCM 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM conquers the world Standardization in the data center begins with the Knürr DCM! The Knürr DCM is the modular building block
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...
Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge... Pivot
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
P System Cubicles. Certified for more safety
P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance
CNC Tool Storage Solutions
CNC Tool Storage Solutions Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes itself in
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries. www.lockweb.com.au
Rose Door Handles We take the worry out of protecting what s valuable to you. Lockwood: no worries www.lockweb.com.au Contents Robert Watson Series 20 Symphony Series 1420 Symphony Series 1360 Series Door
DCF Optimized Rack System
Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
MODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HSR-007
CNC Tool Storage Solutions
CNC Tool Storage Solutions SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
AU-110 racking guide NBXPN: 023
AU-110 racking guide NBXPN: 023 1. Overview NIMBOXX AU-110 Rack Installation This guide provides setup instructions for installing your NIMBOXX AU-110 in a rack. Following these steps in the order given
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Morgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
DELTA3-1. Delta 3 Data Centre Rack Solution
DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers
Mechanical arms, belts and sheets
Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black
Nightscape High performance floodlights and spotlights for discharge lamps
Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
SSG PRODUCTS FOR SHIPS AND OFFSHORE
6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these
Preface nivtec.com 3
nivtec.com Preface nivtec.com 3 nivtec 4 nivtec.com Planning with an Eye for Details nivtec.com 5 prolight+sound 2012 6 nivtec.com Meeting Point Fair Booth nivtec.com 7 Our Preparations 8 nivtec.com Enable
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN
NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN AC SOCKET STRIP (AC Power Distribution) BLANK PANELS x U OPEN RACK THERMOSTAD PANEL SET CABLE MANAGEMENT PANEL WITH COVER BAYING
www.hammondmfg.com General Accessories Hardware
Heavy Duty Door Clamping Junction Box Padlock Kit Quick Release Clamp Replacement hardware for use on all 1418 and 1447 Series enclosures. Formed heavy gauge stainless steel clamp with stainless steel
ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors
Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height
Distribution Boards & Consumer Units
Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories
19 NETbox SOHO Network Wall Mounting Cabinets FAMILY
9 NETbox SOHO Network Wall Mounting Cabinets FAMILY DETAILS: Framework- Top/Bottom Cases: Multi Folded Automated Bending technology applied framework and top/bottom cases, provides a heavy duty structure
Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances
This set of instructions applies to racking and rail kit installation for 6XX and above. The Rack Mounting Instructions section below provides information on installing the SC825 chassis into a rack unit
Quality alu LED profiles
Quality alu LED LED PROFILES - PRODCUT CATALOGUE 2010 Quality Aluminum LED Manufacturer & Designer NEW RECESSED SLIM LINE 15mm Introduction: It is recessed type of the aluminum LED profile to build into
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Cable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
CONTROL DESK SOLUTIONS
DESKS CONTROL DESK SOLUTIONS Three types of solutions: - enclosures with control desk based on Areta system, with door, panel or front shelf - modular desks with and 500 mm depth - monobloc desks. 157
A sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
How To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Installation Detailed installation instructions are provided which should be strictly followed.
Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial
AM/FM ANTENNA KIT (TOUR-PAK MOUNT)
-J077 REV. 008-0-0 AM/FM ANTENNA KIT (TOUR-PAK MOUNT) GENERAL Kit Number 7-98A Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
Casement/Awning Window Parts Reference Catalog
Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100
TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.
NOTE: 2.4m high sliding doors are only available in certain configurations and sizes. Eagle Sidelights & Toplights Sidelights and Toplights are designed to clip onto the Eagle patio door system. The Sidelights
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate 1 Swing Plate Assembly-RM1-0043 1 Swing Plate Kit-5851-2766 (RM1-0043 plus RM1-1091 gear) CAUTION: Fuser may be hot. Turn off printer, unplug it and allow
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia
Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.
know-how Giant in distributing electricity for industry Prisma GK
Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
Product Line 016 2009 DUST. The family of hermetic luminaires
Product Line 016 2009 DUST The family of hermetic luminaires DUST A luminaire for all conditions DUST is the family of hermetic luminaires that works best in spaces of high dustiness and humidity level
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06
EN I. Introduction 02 Specifications 02 Accessories 02 Features 03 II. Installation Instructions 06 1. Installation of the motherboard 06 2. Installation of the power 07 supply 3. Installation of external
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Garage Sectional Doors
Garage Sectional Doors FROM TECKENTRUP TOP CLASS QUALITY DOORS MADE OF STEEL; ALUMINIUM OR WOOD W E O P E N T H E D O O R S F O R P R O G R E S S ECONOMICAL AND SPACE-SAVING FOR EVERY STRUCTURAL SITUATION
Andersen Clad Inswing Entry Doors (2001 to Present)
Andersen Clad Inswing Entry Doors (2001 to Present) What s in This Section Clad Inswing Entry Doors Page 3 Part Illustrations 3 Parts Illustration - Single Door 3 Parts Illustration - Double Door 4 Parts
Secure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate