Medium voltage products UniSec JTI-HBC Secondary distribution switchgear with rapid delivery
|
|
|
- Carmel Jennings
- 9 years ago
- Views:
Transcription
1 Medium voltage products UniSec JTI-HBC Secondary distribution switchgear with rapid delivery
2 UniSec JTI Thought up and built for industry customers The JTI Just To Install acronym indicates a type of medium voltage switchgear for primary and secondary distribution featuring very rapid delivery and putting into service. Delivery time for UniSec JTI switchgear is normally two weeks. By means of a product configurator allowing precise and rapid estimates to be made, the customer receives complete proposals and does not have to make out the technical specifications and design drawings. UniSec JTI switchgear is based on the standard switchgear design and has a range of all types able to satisfy even special plant requirements, thanks both to its electrical characteristics and standard fitting of accessories. UniSec JTI switchgear is always fitted with mechanical and electromechanical interlocks in accordance with the IEC standard. It is available with vacuum circuitbreakers and integrated multifunction apparatus. All solutions have incoming units that comply with CEI 0-16 standards and use the REF601 relay, a or alternatively, the REF542plus unit as the protection unit. The technical design documentation is available immediately and the customer provides official approval of the design right from the offer stage. 2
3 UniSec JTI Characteristics General characteristics Compartments and side pieces made of pre-galvanized or painted metal sheets Front panel doors painted grey RAL 705 colour Removable VD4/R-Sec circuit-breaker HySec multi-function apparatus with vacuum circuitbreaker and SF 6 gas-insulated switch-disconnector KECA 250 B1 current sensors or KEV CD 24 AE combined current/voltage sensors to DIN standards REF601 protection relay or REF542plus microprocessor control and protection unit Incoming unit protection system according to Standard CEI 0-16 December 2012 edition Pre-engineering for earthing by means of movable devices or earthing switch in the incoming unit, on the network side Classification Service continuity: LSC2A Partitions: PM (Metal partitions) Degree of protection IP2X inside the switchgear IPX on the external housing Available mechanical interlocks Line-side isolator and earthing switch Door with earthing switch Circuit-breaker with disconnector (for HySec) Compliance with Standards IEC EN Version Standard internal arc proof on switchgear front Auxiliary circuit voltage 20 V c.a. Electrical ratings Rated voltage kv 24 Test voltage (50 Hz/1 min) kv 50 Impulse withstand voltage kv 125 Rated frequency Hz 50 Rated current A 60 Rated short-time withstand current (1 s) ka 16 Peak current ka 40 Internal arc withstand current (up to IAC AF) (1 s) ka 16
4 UniSec JTI Main components VD4/R-Sec vacuum circuit-breakers G-Sec gas-insulated switch-disconnector HySec multi-function apparatus (with vacuum circuitbreaker and gas-insulated switch-disconnector) 4
5 REF542plus multifunction control and protection unit KEV CD 24 AE combined current/voltage sensor REF 601 protection relay KECA 250 B1 current sensor 5
6 ABB REF 601 UniSec JTI Solutions available with undervoltage coil and protection relay ( N - 51N) JTI A1_F - RLC + HBC switchgear 1 (one) HBC unit with HySec + multifunction apparatus 1 (one) RLC unit with cable inlet on the left Voltage present on busbar side and cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts, undervoltage release and temporary mechanical override of the undervoltage release; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed REF 601 protection relay without protection (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI Pre-engineered for earthing by means of insulating rod on busbar side. The insulating rod is not included in the supply and must be ordered separately L kV - 60A - 16kA x 1" -PFV2 -QAB QBD -BCS -BCN 6
7 Codes for galvanized compartments and side pieces HySec JTI_SEC_A1_F_Z_RLC_N_N_N_HBC 1VCF88000R0700 Basic version without accessories HySec JTI_SEC_A1_F_Z_RLC_N_R_N_HBC 1VCF88000R0701 Anti-condensation heater HySec JTI_SEC_A1_F_Z_RLC_I_N_N_HBC 1VCF88000R0702 Internal lighting HySec JTI_SEC_A1_F_Z_RLC_I_R_N_HBC 1VCF88000R070 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_Z_RLC_N_N_M_HBC 1VCF88000R0704 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_Z_RLC_I_R_M_HBC 1VCF88000R0705 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_A1_F_V_RLC_N_N_N_HBC 1VCF88000R0848 Basic version without accessories HySec JTI_SEC_A1_F_V_RLC_N_R_N_HBC 1VCF88000R0849 Anti-condensation heater HySec JTI_SEC_A1_F_V_RLC_I_N_N_HBC 1VCF88000R0850 Internal lighting HySec JTI_SEC_A1_F_V_RLC_I_R_N_HBC 1VCF88000R0851 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_V_RLC_N_N_M_HBC 1VCF88000R0852 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_V_RLC_I_R_M_HBC 1VCF88000R085 Internal lighting, anti-condensation heater and Completion Description Sales code Insulating rod Movable earthing kit 1VCF88000R0174 Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R1001 7
8 ABB REF 601 UniSec JTI Configurations available with undervoltage coil and protection relay ( N - 51N) JTI A1_F RRC + HBC switchgear 1 (one) HBC unit with HySec + multifunction apparatus 1 (one) RRC unit with cable inlet on the right Voltage present on busbar side and cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts, undervoltage release and temporary mechanical override of the undervoltage release; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay without protection (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to standard CEI Pre-engineered for earthing by means of insulating rod on busbar side. The insulating rod is not included in the supply and must be ordered separately L kV - 60A - 16kA x 1" -PFV2 -QAB QBD -BCS -BCN 8
9 Codes for galvanized compartments and side pieces HySec JTI_SEC_A1_F_Z_RRC_N_N_N_HBC 1VCF88000R0706 Basic version without accessories HySec JTI_SEC_A1_F_Z_RRC_N_R_N_HBC 1VCF88000R0707 Anti-condensation heater HySec JTI_SEC_A1_F_Z_RRC_I_N_N_HBC 1VCF88000R0708 Internal lighting HySec JTI_SEC_A1_F_Z_RRC_I_R_N_HBC 1VCF88000R0709 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_Z_RRC_N_N_M_HBC 1VCF88000R0710 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_Z_RRC_I_R_M_HBC 1VCF88000R0711 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_A1_F_V_RRC_N_N_N_HBC 1VCF88000R0712 Basic version without accessories HySec JTI_SEC_A1_F_V_RRC_N_R_N_HBC 1VCF88000R071 Anti-condensation heater HySec JTI_SEC_A1_F_V_RRC_I_N_N_HBC 1VCF88000R0714 Internal lighting HySec JTI_SEC_A1_F_V_RRC_I_R_N_HBC 1VCF88000R0715 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_V_RRC_N_N_M_HBC 1VCF88000R0716 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_V_RRC_I_R_M_HBC 1VCF88000R0717 Internal lighting, anti-condensation heater and Completion Description Sales code Insulating rod Movable earthing kit 1VCF88000R0174 Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R1001 9
10 ABB REF 601 UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N) JTI A1_F_DL RLC + HBC switchgear 1 (one) HBC unit with HySec + multifunction apparatus 1 (one) RLC unit with cable inlet on the left Voltage present on busbar side and cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay with Data Logger, Modbus communication and RS 485 serial output (51,I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI 0-16 (**). Pre-engineered for earthing by means of insulating rod on busbar side. The insulating rod is not included in the supply and must be ordered separately L kV - 60A - 16kA x 1" -PFV2 -QAB QBD -BCS -BCN (**) The software for the Data Logger function can be downloaded free of charge from our website: portale CEI 0-16 A USB/RS485 converter is required. We recommend use of a MOXA Uport 110 v.1.4 converter 10
11 Codes for galvanized compartments and side pieces HySec JTI_SEC_A1_F_DL_Z_RLC_N_N_N_HBC 1VCF88000R0718 Basic version without accessories HySec JTI_SEC_A1_F_DL_Z_RLC_N_R_N_HBC 1VCF88000R0719 Anti-condensation heater HySec JTI_SEC_A1_F_DL_Z_RLC_I_N_N_HBC 1VCF88000R0720 Internal lighting HySec JTI_SEC_A1_F_DL_Z_RLC_I_R_N_HBC 1VCF88000R0854 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_DL_Z_RLC_N_N_M_HBC 1VCF88000R0721 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_DL_Z_RLC_I_R_M_HBC 1VCF88000R0722 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_A1_F_DL_V_RLC_N_N_N_HBC 1VCF88000R072 Basic version without accessories HySec JTI_SEC_A1_F_DL_V_RLC_N_R_N_HBC 1VCF88000R0724 Anti-condensation heater HySec JTI_SEC_A1_F_DL_V_RLC_I_N_N_HBC 1VCF88000R0725 Internal lighting HySec JTI_SEC_A1_F_DL_V_RLC_I_R_N_HBC 1VCF88000R0855 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_DL_V_RLC_N_N_M_HBC 1VCF88000R0726 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_DL_V_RLC_I_R_M_HBC 1VCF88000R0727 Internal lighting, anti-condensation heater and Completion Description Sales code Insulating rod Movable earthing kit 1VCF88000R0174 Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R
12 ABB REF 601 UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N) JTI A1_F_DL RRC + HBC switchgear 1 (one) HBC unit with HySec + multifunction apparatus 1 (one) RRC unit with cable inlet on the right Voltage present on busbar side and cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay with Data Logger, Modbus communication and RS 485 serial output (51,I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI 0-16 (**). Pre-engineered for earthing by means of insulating rod on busbar side. The insulating rod is not included in the supply and must be ordered separately L kV - 60A - 16kA x 1" -PFV2 -QAB QBD -BCS -BCN (**) The software for the Data Logger function can be downloaded free of charge from our website: portale CEI 0-16 A USB/RS485 converter is required. We recommend use of a MOXA Uport 110 v.1.4 converter 12
13 Codes for galvanized compartments and side pieces HySec JTI_SEC_A1_F_DL_Z_RRC_N_N_N_HBC 1VCF88000R0728 Basic version without accessories HySec JTI_SEC_A1_F_DL_Z_RRC_N_R_N_HBC 1VCF88000R0729 Anti-condensation heater HySec JTI_SEC_A1_F_DL_Z_RRC_I_N_N_HBC 1VCF88000R070 Internal lighting HySec JTI_SEC_A1_F_DL_Z_RRC_I_R_N_HBC 1VCF88000R071 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_DL_Z_RRC_N_N_M_HBC 1VCF88000R072 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_DL_Z_RRC_I_R_M_HBC 1VCF88000R07 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_A1_F_DL_V_RRC_N_N_N_HBC 1VCF88000R074 Basic version without accessories HySec JTI_SEC_A1_F_DL_V_RRC_N_R_N_HBC 1VCF88000R075 Anti-condensation heater HySec JTI_SEC_A1_F_DL_V_RRC_I_N_N_HBC 1VCF88000R076 Internal lighting HySec JTI_SEC_A1_F_DL_V_RRC_I_R_N_HBC 1VCF88000R077 Internal lighting and anti-condensation heater HySec JTI_SEC_A1_F_DL_V_RRC_N_N_M_HBC 1VCF88000R078 Motor-operated circuit-breaker HySec JTI_SEC_A1_F_DL_V_RRC_I_R_M_HBC 1VCF88000R079 Internal lighting, anti-condensation heater and Completion Description Sales code Insulating rod Movable earthing kit 1VCF88000R0174 Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R1001 1
14 ABB REF 601 ABB REF 601 ABB REF 601 UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N) JTI B1_DL switchgear 1 (one) incoming feeder with HBC + Unit 2 (two) transformer protections with HBC Unit CEI 0-16 incoming unit Voltage present on cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. Earthing switch on utility undertaking's side with key under the responsibility of the utility undertaking, in accordance with Standard CEI REF 601 protection relay with Data Logger, Modbus communication and RS 485 serial output (51,I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI 0-16 (**) L 500 L 500 L Transformer protection unit Voltage present on cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay without protection (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to the IEC standard. -QAB QBD -BCS 24kV - 60A - 16kA x 1" -QAB QBD -BCS -QAB QBD -BCS -BCN -BCN -BCN (**) The software for the Data Logger function can be downloaded free of charge from our website: portale CEI 0-16 A USB/RS485 converter is required. We recommend use of a MOXA Uport 110 v.1.4 converter 14
15 Codes for galvanized compartments and side pieces HySec JTI_SEC_B1_DL_Z_N_N_N_HBC 1VCF88000R0764 Basic version without accessories HySec JTI_SEC_B1_DL_Z_N_R_N_HBC 1VCF88000R0765 Anti-condensation heater HySec JTI_SEC_B1_DL_Z_I_N_N_HBC 1VCF88000R0766 Internal lighting HySec JTI_SEC_B1_DL_Z_I_R_N_HBC 1VCF88000R0767 Internal lighting and anti-condensation heater HySec JTI_SEC_B1_DL_Z_N_N_M_HBC 1VCF88000R0768 Motor-operated circuit-breaker HySec JTI_SEC_B1_DL_Z_I_R_M_HBC 1VCF88000R0769 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_B1_DL_V_N_N_N_HBC 1VCF88000R0770 Basic version without accessories HySec JTI_SEC_B1_DL_V_N_R_N_HBC 1VCF88000R0771 Anti-condensation heater HySec JTI_SEC_B1_DL_V_I_N_N_HBC 1VCF88000R0772 Internal lighting HySec JTI_SEC_B1_DL_V_I_R_N_HBC 1VCF88000R077 Internal lighting and anti-condensation heater HySec JTI_SEC_B1_DL_V_N_N_M_HBC 1VCF88000R0774 Motor-operated circuit-breaker HySec JTI_SEC_B1_DL_V_I_R_M_HBC 1VCF88000R0775 Internal lighting, anti-condensation heater and Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R100 15
16 SEZIONATORE MANOVRABILE SOLO DOPO L'INTERVENTO DEL DISTRIBUTORE EARTHING SWITCH TO BE OPERATED ONLY AFTER ENERGY NETWORK ACTION -AA ABB REF 601 ABB REF 601 UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N - 67N) JTI B2_DL switchgear 1 (one) incoming feeder with SBR + Unit 2 (two) transformer protections with HBC Unit CEI 0-16 SBR incoming unit Voltage present on busbar side and cable side. VD4/R-Sec p20 circuit-breaker with or without motor, with shunt opening release, shunt closing release, NO + 4NC aux. contacts, operation counter and springs loaded signalling. REF542plus control and protection unit (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>; 67NI; 67NC) with Data Logger and ABB type KEVCD current/voltage sensors installed inside the busbar compartment and toroid for earth fault conforming to Standard CEI G-Sec switch-disconnector with: 1 removable key with line-side isolator in the closed 1 removable key with earthing switch in the closed position and 1 removable key with earthing switch in the open position; auxiliary contacts: 4 NO or NC for the feeder disconnector and 4 NO or NC for the earthing switch. Earthing switch on utility undertaking's side with key under the responsibility of the utility undertaking, in accordance with Standard CEI L 500 L P1 -BZ P2 24kV - 60A - 16kA x 1" Transformer protection unit Voltage present on cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay without protection (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>,68), with current sensors and toroid for earth fault, conforming to the IEC standard. -AA -QCE1 -PFV2 -QAB -QBS -QCE -BCN -QAB QBD -BCS -BCN -QAB QBD -BCS -BCN 16
17 Codes for galvanized compartments and side pieces HySec VD4/R JTI_SEC_B2_DL_Z_N_N_N_HBC 1VCF88000R0776 Basic version without accessories HySec VD4/R JTI_SEC_B2_DL_Z_N_R_N_HBC 1VCF88000R0777 Anti-condensation heater HySec VD4/R JTI_SEC_B2_DL_Z_I_N_N_HBC 1VCF88000R0778 Internal lighting HySec VD4/R JTI_SEC_B2_DL_Z_I_R_N_HBC 1VCF88000R0779 Internal lighting and anti-condensation heater HySec VD4/R JTI_SEC_B2_DL_Z_N_N_M_HBC 1VCF88000R0780 Motor-operated circuit-breaker HySec VD4/R JTI_SEC_B2_DL_Z_I_R_M_HBC 1VCF88000R0781 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec VD4/R JTI_SEC_B2_DL_V_N_N_N_HBC 1VCF88000R0782 Basic version without accessories HySec VD4/R JTI_SEC_B2_DL_V_N_R_N_HBC 1VCF88000R078 Anti-condensation heater HySec VD4/R JTI_SEC_B2_DL_V_I_N_N_HBC 1VCF88000R0784 Internal lighting HySec VD4/R JTI_SEC_B2_DL_V_I_R_N_HBC 1VCF88000R0785 Internal lighting and anti-condensation heater HySec VD4/R JTI_SEC_B2_DL_V_N_N_M_HBC 1VCF88000R0786 Motor-operated circuit-breaker HySec VD4/R JTI_SEC_B2_DL_V_I_R_M_HBC 1VCF88000R0787 Internal lighting, anti-condensation heater and Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R
18 ABB REF 601 L1 L2 L L1 L2 L UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N) JTI B_DL switchgear 1 (one) incoming feeder with HBC + Unit 2 (two) transformer protections with SFC Unit Incoming unit Voltage present on cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay with Data Logger, Modbus communication and RS 485 serial output (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI 0-16 (**) L 1700 SFC transformer protection unit (width of unit 500 mm) Voltage present on cable side. G-Sec gas-insulated switch-disconnector with: 1 removable key with line isolator in the open position; 1 removable key with earthing switch in the closed shunt opening release; fuseholder; mechanical release system for tripped fuse; fuse tripped signalling contact; auxiliary contacts: 4 NO or NC for the feeder disconnector and 4 NO or NC for the earthing switch. Supply does not include fuses unless ordered separately kV - 60A - 16kA x 1" QBS -QAB -FCF -FCF QBD 11 -QBS -BCS -QCE -QCE -BCN (**) The software for the Data Logger function can be downloaded free of charge from our website: portale CEI 0-16 A USB/RS485 converter is required. We recommend use of a MOXA Uport 110 v.1.4 converter 18
19 Codes for galvanized compartments and side pieces HySec JTI_SEC_B_DL_Z_N_N_N_HBC 1VCF88000R0788 Basic version without accessories HySec JTI_SEC_B_DL_Z_N_R_N_HBC 1VCF88000R0789 Anti-condensation heater HySec JTI_SEC_B_DL_Z_I_N_N_HBC 1VCF88000R0790 Internal lighting HySec JTI_SEC_B_DL_Z_I_R_N_HBC 1VCF88000R0791 Internal lighting and anti-condensation heater HySec JTI_SEC_B_DL_Z_N_N_M_HBC 1VCF88000R0792 Motor-operated circuit-breaker HySec JTI_SEC_B_DL_Z_I_R_M_HBC 1VCF88000R079 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_B_DL_V_N_N_N_HBC 1VCF88000R0794 Basic version without accessories HySec JTI_SEC_B_DL_V_N_R_N_HBC 1VCF88000R0795 Anti-condensation heater HySec JTI_SEC_B_DL_V_I_N_N_HBC 1VCF88000R0796 Internal lighting HySec JTI_SEC_B_DL_V_I_R_N_HBC 1VCF88000R0797 Internal lighting and anti-condensation heater HySec JTI_SEC_B_DL_V_N_N_M_HBC 1VCF88000R0798 Motor-operated circuit-breaker HySec JTI_SEC_B_DL_V_I_R_M_HBC 1VCF88000R0799 Internal lighting, anti-condensation heater and Fuse for SFC units Sales code Note 24 kv 16A 1VCF88000R0167 To order in multiples of 24 kv 25A 1VCF88000R0168 To order in multiples of 24 kv 40A 1VCF88000R0169 To order in multiples of 24 kv 50A 1VCF88000R0170 To order in multiples of 24 kv 6A 1VCF88000R0171 To order in multiples of 24 kv 80A 1VCF88000R0172 To order in multiples of Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R100 19
20 L1 L1 L2 L2 L L L1 L1 L2 L2 L L UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N) JTI B4_DL switchgear 1 (one) incoming feeder with HBC + Unit 2 (two) transformer protections with SFC Unit Incoming unit Voltage present on cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor, with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed Earthing switch on utility undertaking's side with key under the responsibility of the utility undertaking, in accordance with Standard CEI REF 601 protection relay with Data Logger, Modbus communication and RS 485 serial output (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI 0-16 (**) ABB REF 601 L 1700 SFC transformer protection unit (width of unit 75 mm) Voltage present on cable side. G-Sec gas-insulated switch-disconnector with: 1 removable key with line isolator in the open position; 1 removable key with earthing switch in the closed shunt opening release; fuseholder; mechanical release system for tripped fuse; fuse tripped signalling contact; auxiliary contacts: 4 NO or NC for the feeder disconnector and 4 NO or NC for the earthing switch. 27 -QAB QBD -BCS kV - 60A - 16kA x 1" QBS -FCF -QCE QBS -FCF -QCE -BCN (**) The software for the Data Logger function can be downloaded free of charge from our website: portale CEI 0-16 A USB/RS485 converter is required. We recommend use of a MOXA Uport 110 v.1.4 converter 20
21 Supply does not include fuses unless ordered separately. Codes for galvanized compartments and side pieces HySec JTI_SEC_B4_DL_Z_N_N_N_HBC 1VCF88000R0800 Basic version without accessories HySec JTI_SEC_B4_DL_Z_N_R_N_HBC 1VCF88000R0801 Anti-condensation heater HySec JTI_SEC_B4_DL_Z_I_N_N_HBC 1VCF88000R0802 Internal lighting HySec JTI_SEC_B4_DL_Z_I_R_N_HBC 1VCF88000R080 Internal lighting and anti-condensation heater HySec JTI_SEC_B4_DL_Z_N_N_M_HBC 1VCF88000R0804 Motor-operated circuit-breaker HySec JTI_SEC_B4_DL_Z_I_R_M_HBC 1VCF88000R0805 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_B4_DL_V_N_N_N_HBC 1VCF88000R0806 Basic version without accessories HySec JTI_SEC_B4_DL_V_N_R_N_HBC 1VCF88000R0807 Anti-condensation heater HySec JTI_SEC_B4_DL_V_I_N_N_HBC 1VCF88000R0808 Internal lighting HySec JTI_SEC_B4_DL_V_I_R_N_HBC 1VCF88000R0809 Internal lighting and anti-condensation heater HySec JTI_SEC_B4_DL_V_N_N_M_HBC 1VCF88000R0810 Motor-operated circuit-breaker HySec JTI_SEC_B4_DL_V_I_R_M_HBC 1VCF88000R0811 Internal lighting, anti-condensation heater and Fuse for SFC units Sales code Note 24 kv 16A 1VCF88000R0167 To order in multiples of 24 kv 25A 1VCF88000R0168 To order in multiples of 24 kv 40A 1VCF88000R0169 To order in multiples of 24 kv 50A 1VCF88000R0170 To order in multiples of 24 kv 6A 1VCF88000R0171 To order in multiples of 24 kv 80A 1VCF88000R0172 To order in multiples of Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R
22 ABB REF 601 UniSec JTI Configurations available with Data Logger and protection relay ( N - 51N) JTI C1_AC_DL switchgear 1 (one) Incoming/Outgoing unit with cable outlet from below and inlet from above Voltage present on busbar side and cable side. HySec p20 multifunction apparatus comprising: Vacuum circuit-breaker with or without motor (**), with shunt opening release, shunt closing release, operation counter, 6NO + 6NC aux. contacts; SF 6 switch-disconnector with: - 1 removable key with line-side isolator in the closed - 1 removable key with earthing switch in the closed position and 1 removable key in the open position. REF 601 protection relay with Data Logger, Modbus communication and RS 485 serial output (51, I>; 51, I>>; 50, I>>>; 51N, Io>; 50N, Io>>, 68), with current sensors and toroid for earth fault, conforming to Standard CEI 0-16 (***) Pre-engineered for earthing by means of an earthing stick on the distributor side. The earthing stick is not included in the supply and must be ordered separately L PFV2 -QAB QBD -BCS -BCN Non internal arc proof solution (**) (***) The software for the Data Logger function can be downloaded free of charge from our website: portale CEI 0-16 A USB/RS485 converter is required We recommend use of a MOXA Uport 110 v.1.4 converter 22
23 Codes for galvanized compartments and side pieces HySec JTI_SEC_C1_AC_DL_Z_N_N_N_HBC 1VCF88000R086 Basic version without accessories HySec JTI_SEC_C1_AC_DL_Z_N_R_N_HBC 1VCF88000R087 Anti-condensation heater HySec JTI_SEC_C1_AC_DL_Z_I_N_N_HBC 1VCF88000R088 Internal lighting HySec JTI_SEC_C1_AC_DL_Z_I_R_N_HBC 1VCF88000R089 Internal lighting and anti-condensation heater HySec JTI_SEC_C1_AC_DL_Z_N_N_M_HBC 1VCF88000R0840 Motor-operated circuit-breaker HySec JTI_SEC_C1_AC_DL_Z_I_R_M_HBC 1VCF88000R0841 Internal lighting, anti-condensation heater and Codes for painted compartments and side pieces HySec JTI_SEC_C1_AC_DL_V_N_N_N_HBC 1VCF88000R0842 Basic version without accessories HySec JTI_SEC_C1_AC_DL_V_N_R_N_HBC 1VCF88000R084 Anti-condensation heater HySec JTI_SEC_C1_AC_DL_V_I_N_N_HBC 1VCF88000R0844 Internal lighting HySec JTI_SEC_C1_AC_DL_V_I_R_N_HBC 1VCF88000R0845 Internal lighting and anti-condensation heater HySec JTI_SEC_C1_AC_DL_V_N_N_M_HBC 1VCF88000R0846 Motor-operated circuit-breaker HySec JTI_SEC_C1_AC_DL_V_I_R_M_HBC 1VCF88000R0847 Internal lighting, anti-condensation heater and Completion Description Sales code Insulating rod Movable earthing kit 1VCF88000R0174 Completion Height Sales code Height adjustment plinth 00 mm 1VCF88000R1007 2
24 UniSec JTI Configurations available JTI (TR) switchgear 1 (one) transformer box unit The transformer box unit is only available in the standard version. The transformer box is made of galvanized sheet metal with doors painted in standard RAL 705 colour. It is supplied in an assembly kit and can be fitted with internal lighting. Please contact us if transformer boxes with other dimensions are required. Available types Unit W [mm] D [mm] H [mm] TR TR TR TR TR H W D Choosing the transformer box units After having defined the type of transformer box unit in relation to the total losses of the transformer, check to make sure that the dimensions of the box unit are sufficient to ensure adequate insulation distances. Maximum operating temperature of the transformer No-load losses Load losses Load factor Rated current Total losses T [ C] Wo [W] Wcc [W] a In [A] Ptot. = Wo + a2 x Wcc Type of box Total losses [W] T=100 C T=120 C T=140 C TR TR TR TR TR Description of unit TR1 TR2 TR TR4 TR5 Sales code 1VCF88000R016 1VCF88000R0164 1VCF88000R0165 1VCF88000R0166 1VCF88000R017 24
25 Notes
26 Notes
27
28 Contact us ABB S.p.A. Power Products Division Unità Operativa Sace-MV Via Friuli, 4 I Dalmine Tel: Fax: [email protected] The data and illustrations are not binding. We reserve the right to make changes in the course of technical development of the product. Copyright 2015 ABB. All rights reserved. 1VCP00050 Rev. A, en Technical catalogue (UniSec JTI-HBC) (mt)
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
DS1 Diode-based transient-free capacitor switch
Medium voltage products DS1 Diode-based transient-free capacitor switch Power and productivity for a better world TM Compensation of reactive power DS1 the future of switches Compensation of reactive power
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
Medium Voltage Products. PR512 Microprocessor-based self-supplied protection relays
Medium Voltage Products PR512 Microprocessor-based self-supplied protection relays DESCRIPTION CHARACTERISTICS AND ORDERING CODES PR512/P (50-51) UNIT PR512/P (50-51-50N-51N) UNIT PR512/PD (50-51-50N-51N
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens.
Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany www.siemens.com/energy For questions on power transmission and distribution, please contact
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's
Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's Catalogue 2011 Aktif trade mark for Medium voltage switchgears, Switching equipment and Kiosks with high quality and environmentally
Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications
Medium voltage products UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications 2 Index 4 1. Description 6 2. Air insulated switchgear 10 3. IEC Classification 12 4. Design features
CAS 36 Ring Main Unit
Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly
UFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125
Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services
Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms
Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms The future of Wind Farms As offshore wind farms move towards deploying higher capacity
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
MNS is Switchgear System Technical Overview
Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
Safe and secure distribution of medium voltage with AX1
Safe and secure distribution of medium voltage with AX1 The intelligent switchgear AX1 is a modern, air-insulated switchgear that lies at the very front line of safety and security safety for operating
SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear
Technical catalogue TK 503/01 E ZX0.2 Gas-insulated medium voltage switchgear Contents Page 1 Applications 4 2 Characteristics 5 3 Your benefit 6 4 Technical data 7 4.1 Technical data of the panel 7 4.2
Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications
Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications Complete solution for indoor applications ABB s products provides safe, reliable and smart technologies for the
MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage
DI-2 MEDIUM VOLTAGE SWITCHGEAR BUILT TO LAST! DI-2, a modular concept combining all mediumvoltage functions. DI-2 S modular design allows you to create rational, economical & custom-made combinations of
High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv
High-Voltage Compact Switchgear AP1 DTC for 1 kv and kv Answers for energy. The AP1 DTC Complying with our Customers demands Experience you can rely on - at anytime, anywhere Decades of experience in high-voltage
Electrical Shore Connections / Cold Ironing
STANDARD FOR CERTIFICATION No. 2.25 Electrical Shore Connections / Cold Ironing JULY 2014 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution
High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching
Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon
Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
How To Make A Power Supply From A Power Generator
Medium voltage products UniGear ZS1 Medium voltage, arc-proof, air insulated switchgear up to 24 kv insulated voltage Index 1. UniGear ZS1 4 Description 8 IEC Classification 10 Design features 12 Fully
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
Medium Voltage Distribution Catalogue 2014 FBX. Gas insulated switchgear up to 24 kv
Medium Voltage Distribution Catalogue 2014 FBX Gas insulated switchgear up to 24 kv FBX General contents Presentation 3 FBX range 9 Use 15 Characteristics 23 Accessories and options 33 Installation 41
Engineering Specification
Engineering Specification Electrical 33KV AC INDOOR SWITCHGEAR NON-WITHDRAWABLE Owner: Approved by: Chief Engineer, Electrical Neal Hook Chief Engineer Electrical Authorised by: Version 2.1 Issued May
www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.
s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage
MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx
MEDIUM VOLTAGE SWITCHGEAR for secondary distribution CATALOGUE Code: P2490_xx CONTENTS 1 About us 2 Medium Voltage Business Unit Portfolio 3 Overview 8 Medium Voltage Switchgear Types. Equipment used.
SIVACON The Versatile Low-Voltage Switchboard
s SIVACON The Versatile Low-Voltage Switchboard Type-Tested Power Distribution Board 8PT The Obvious Solution for Global Challenges SIVACON Type testing in low-voltage switchgear is increasingly becoming
The power distribution board that sets new standards
SIVACON The power distribution board that sets new standards SIVACON S4 safe, cost-efficient and flexible Answers for infrastructure. Contents We support you with system 04 05 Maximum safety is our top
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
Medium Voltage Switchgear
Uniswitch Medium Voltage Switchgear 12 kv, 17.5 kv, 24 kv 630 A and 1250 A Operation and TABLE OF CONTENTS 1 Summary...1 1.1 General...1 1.2 Standards and specifications...2 1.3 Service conditions...3
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV
Installation, Operation and Maintenance Instructions Uniflex ABB PTMV SAFETY FIRST! For safe and correct usage note the following recommendations: Only install switchgear and switchboards in enclosed rooms
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Automation Products. Low Voltage Switchgear MNS System Overview
Automation Products Low Voltage Switchgear MNS System Overview Inroduction to the MNS System ABB is the global leader for production of a wide range of low voltage energy systems. In 1992 ABB started operations
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010
Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage
AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
Emax DC. Annex to the technical catalogue. Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications
Annex to the technical catalogue Emax DC Low voltage Switch-disconnectors and Automatic circuit-breakers for Direct Current Applications 1SDC200012D0201 Index SACE Emax DC automatic circuit-breakers...
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M
ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current
MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC 62271-200 7.2 /12 /15 kv 25, 31.5, 40 ka
SWITCHGEAR AND CONTROLGEAR MODEL MS-E IEC 6227- /2 /5 kv,, ka The MS-E conforms to IEC 6227- standard and is designed and manufactured utilising Mitsubishi Electric state-of-the-art technology, fully taking
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
Portfolio of Solutions. High and Medium Voltage Switchgear
Portfolio of Solutions High and Medium Voltage Switchgear Efacec Switchgear Efacec is a leading company in Portugal and a worldwide reference in the development of solutions for Power Generation, Transmission,
Emirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager
Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager SACE Emax 2 From Circuit-Breaker to Power Manager Our customers need more efficient solutions, to Increase
Arc Protection Relay REA 101. Operator s Manual
Arc Protection Relay 1MRS751003-MUM Issued: 08.04.1998 Version: F/23.06.2005 Arc Protection Relay 1. About this manual...5 1.1. Copyrights...5 1.2. Trademarks...5 1.3. Guarantee...5 1.4. General...5 1.5.
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)
8 ABB_11_E_08 13.08.2007 9:07 Uhr Seite 379 8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage) 8.1 Switchgear apparatus (< 52 kv) This voltage range
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
Low Voltage Switchboards The Best Technical Solution for Your Ship
The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.
IEC 61850 in ZX Gas-insulated medium voltage switchgear
IEC 61850 in ZX Gas-insulated medium voltage switchgear IEC 61850 in ZX Just as the supply of electrical power is becoming more and more important in a networked world, demands for the integration of electrical
Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application
Product overview brochure ABB Medium Voltage Products Our one-stop approach for every medium voltage application Overview ABB meets every need for reliable, safe and energy-efficient medium voltage switchgear,
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact
ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact Authors Carl Ejnar Sölver, ABB High Voltage Products Rasmus Larsson, ABB High Voltage Products 2 ABB ABB
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of
SENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
Masterclad Medium Voltage Passive Arc-Resistant Switchgear
Masterclad Medium Voltage Passive Arc-Resistant Switchgear Square D Masterclad medium voltage passive arc-resistant (AR) switchgear is designed with utilities and industrial customers in mind who demand
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
TriLine ASSEMBLY System PowerModules
04 2012 TriLine ASSEMBLY System PowerModules TriLine ASSEMBLY system Contents Introduction The new modular system intelligence 2 Delivery formats 8 EDS PowerCon configuration software 10 Technical specifications
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
ABB turnkey stations ULTRA-MVC-S 770 to 3110 kw
Solar inverters ABB turnkey stations LTRA-MC-S 770 to 3110 k Turnkey solutions comprising an LTRA series inverter and a Medium oltage Compartment (MC-S). The new LTRA-MC-S has been specifically developed
Medium voltage product. Instrument transformers for indoor applications Product overview
Medium voltage product Instrument transformers for indoor applications Product overview 02 Contents Introduction Current transformers Supporting type 6 TPU, TPE 7 KOFA, IHBF 10 Dummy Bus type 8 KOKS 12,
Spare parts Catalogue
Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00 Not every original spare parts are really original spare parts. Availability of spare parts for
DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium
DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT User Manual SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium +32 (0)9/321.91.12 - Fax +32 (0)9/321.91.13 - e-mail: [email protected]
Medium Voltage Products. V-Contact Medium voltage vacuum contactors
Medium Voltage Products V-Contact Medium voltage vacuum contactors DESCRIPTION CONTACTOR SELECTION AND ORDERING 2 UNIMOTOR ENCLOSURE SELECTION AND ORDERING POWERCUBE UNITS SPECIFIC PRODUCT CHARACTERISTICS
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
Distribution Boards & Consumer Units
Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories
ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG TEL. +49 87 61 6 81-0 FAX +49 87 61 68 12 30
40 DRIESCHER - Low voltage fusedswitch-disconnector system 40 Rated current upto 445 A 40 84 40 40 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-8566 MOOSBURG TEL. +49 87 6 6 8-0 FAX +49 87 6
