SUMMIT Digital flow computer with graphic display
|
|
|
- Erica Conley
- 9 years ago
- Views:
Transcription
1 SUMMIT 8800 Digital flow computer with graphic display Lower OPEX and CAPEX due to modern design and communication Low inventory cost with one computer fits all due to modularity of hard and software More effective maintenance and operator due to colour graphics touch screen Minimize service cost and automatic remote metering with unsurpassed network support Increased accuracy and reduce re-calibrations with automatic performance monitoring
2 Achieve more in Flow Computing In 1982 we were one of the first companies to produce a micro-processorbased flow computer. We have seen the technology become established, but there has been little change to the initial concepts. Create a flow computer that will increase performance, save time and be more cost effective and have the best possible accuracy.! We took up the challenge, and the result is the new Summit Summit 8800 bring the flow computer into the communication age. Handling: Communication: Processing: Security Versatility: Accuracy Wide use: Scroll & Click menu navigation Touch Screen operation Multicolour traffic-light guidance Fully redundant Ethernet LAN Local Area Network capability Dedicated processor per I/O board Multi-level access and authorization levels Full audit trail Separation of fiscal and maintenance data 4GB removable memory Plug-in boards for more streams, analysers, or communications Fully digital, highly accurate analysis Fast processing with true 1/4 sec. Any metering type Oil; Gas; Steam; Water
3 u innovative Concept Putting brain power into flow computing. Create a flow computer that will increase performance, save time and be more cost effective! Summit 8800, taking flow computing to new heights. The current Digital Flow Computers have been around since the 1980 s and are limited in their functionality and their human interface. Summit 8800 has overcome these limitations by utilising the tremendous advances in computers since then. You will experience optimization at all levels, including, of course HART, A/D, the speed of access, calculation and operation. Navigator - the right way The most obvious improvement is the operator interface. We chose a large colour graphics screen with touch sensitive screen. The operator now has a simultaneous overview of all the important measurements, parameters and alarms in easy-to-understand colour. The graphics also allow historical trends and even mimic displays. Operation is as simple as pointing a finger or turning a dial. The user is guided through the menus and can select one by touching the screen, or with a scroll-and-click of the Navigator dial. For data entry a numeric or typewriter style keyboard can be displayed on screen. Power to spare Hidden deeper in the computer are the true changes in the computing power. With its 32 bit processor, more than 64 Mbyte memory and 4 GB of disk space on its SD card the computer resembles a high powered PC. Moreover, a typical flow computer configuration has three of these processors. Fully loaded, seven of these processors handle up to 18 serial and 12 Ethernet network interfaces. So it is no surprise that we can safely guarantee that each of the 5 fiscal streams will be reliably measured every quarter of a second.
4 Configuration: Anything goes u total Adaptability Fiscal metering and allocation metering with one and the same flow computer Most current flow computers have been designed for custody transfer applications. The result is that they are typically too slow and hardly economical for multiple allocation metering. Total Flow Report Our engineers decided that with current state of technology you can do better. They designed a computer that can handle up to 5 meters in one chassis and do all calculations within 1/4 second or better. Thanks to slot-in boards in a single chassis, Summit 8800 is very affordable. Now the same flow computer can handle fiscal and allocation applications, which makes engineering and maintenance easier. Allocation metering with totalization Liquid, gas, steam The Summit 8800 has been designed for any metering application including hydrocarbon liquids, dry natural gas, steam, industrial gases, water. Summit 8800 supports the most important measurement standards such as AGA, ISO and API. Mix and match different meter types Each flow computer can handle any meter type, such as turbine, Coriolis, PD orifice, venture and ultrasonic, or provers. For each individual stream the meter type and medium can be specified. So individual boards in a single flow computer can handle for instance an ultrasonic oil meter, a turbine water meter and an orifice gas meter. Other functions The Summit 8800 is not limited to metering only. All essential functions have been integrated: Flow computer redundancy Totalizing of several runs in or outgoing runs, Automatic proving including proving report Batching GC data distribution throughout a pipeline Run switching Flow proportional sampling Transmitter validation and calibration Redundant flow computer configuration Configuration with run switching and totalization
5 u total Flexibility Networking flexibility leads to substantially lower maintenance costs Ethernet The new flexibility of networking Meter Printer GC Meter Networking and Ethernet communication has made life far easier. Now we can plug our computers, printers, copiers and even telephones in one and the same connector. The capabilities of flow computers lagged behind. Local Area Network Our engineers have integrated state-of-the-art communication technology alongside more traditional communication methods. The Summit 8800 can handle a combination of several serial and Ethernet ports. Reports can be printed by a FTP network printer and even sent in an SMTP . Meter Meter Meter Pulses Printer Local Area network The preferred communication nowadays is TCP/IP which is standard for any Ethernet network. We added the security of multiple Ethernet ports to support redundancy and to separate the process from operation. Ethernet makes metering much simpler and safer to communicate with equipment such as supervisory systems, PLC, DCS, flow meters, chromatographs, printers, etc. Flow computer - Proving system Ethernet Prover Flow computer - Prover system Small flow computer-based systems, such as a proving system, can easily be created. Each flow computer can handle one stream, while a prover computer handles the automatic proving sequence, all within a network or in one housing GC Redundancy Because Summit 8800 has multiple Ethernet ports, there is no problem to create a redundant communication network, even when the flow meter also requires an Ethernet port. To guarantee security each port is completely independent from each other, so communication failure on one port will not affect another port. Meter Meter Redundant communication network
6 Communication minimizes maintenance Remote capabilities will make a difference when multiple stations are installed at different locations. Remote monitoring - web enabled Whether it s an FPSO out in the ocean, a shuttle tanker off- or onloading, an oil rig offshore or a tank farm in the dessert or a pipeline in the tundra. You are effectively there, whenever you wish. Each Summit 8800 can have its own integrated web site. This lets you view all data on any chosen PC, laptop, tablet, or even a mobile phone, if security permits. And we ve added a further security aspect by separating fiscal data from meter operation and maintenance data. Remote metering means instant billing Immediate access to data now allows you to schedule billing with split-second accuracy. Energy measurements through GC sharing With the current importance being attached to energy versus volume, it would be ideal to install GC s throughout the pipeline... but impractical. The optional Summit 8800 network allows you to transfer GC data from one flow computer to the other. From your laptop you can access a website containing your Summit flow computer, simulating on your screen the data from your remote flow computer. Weather, distance, schedules, personnel availability, visas - they no longer play a role. Your connection can be made secure, protected and validated.
7 u cost-saving Investment Modularity and expandability Minimize inventory and upgrade costs Only pay for the hardware you need Most traditional flow computers won t grow with your needs. Their rigid design in hardware often means that different models are needed for single and multiple streams. When an extra run is needed, you are forced to replace the complete unit. The basic design for a single stream... Summit 8800 in contrast has a modular design: just add the components required. The basic chassis has a colour graphic display and 6 slots for optional boards. Run boards and communication boards can be slotted in as needed, to cover a full range of a single fiscal stream up to 5 streams and a prover. Now the same hardware can be used for a wide range of applications. Maintain calculation speed In traditional designs, the calculation speed often dramatically decreases with increasing number of runs or additional communication. In our design each card has its own processor, the processing power increases with each additional card. The calculation cycle can therefore easily be retained while the number of streams increases or when additional communication is needed. The Summit 8800 therefore has an impressive TRUE quarter of a second cycle.... can be expanded inexpensively in minutes with plug-in boards Expand the memory In traditional designs, the memory is limited and fixed. But the demand for memory has increased: the API requirement for 35 days of history, for example, is already a problem for several flow computers. The Summit 8800 has an internal memory of 64 MB and a removable SD card with enough Gbyte for a lifetime of data. Future proof During the last decade a lot of changes have occurred, not only in the meter types, but more markedly in the communication field. Summit 8800 is designed for most of the current requirements, such as smart indexes and mobile communication. Software-reconfigurable hardware is used to enable new functionality. Plug-in boards are easy to add or exchange so the computer will not easily become obsolete.
8 One flow computer for all applications Facilitate plant design u lower Maintenance Software options reduces engineering costs down to new level Configuration has always been a compromise between ease of use and ultimate capabilities. Most computers only offer one choice: either menu driven with the limitation of pre-configured capabilities; or programming with the need for specialised personnel. Summit 8800 is a chameleon offering the choices needed for any type of application. Menu driven: quick and easy Most people will simply select the menu driven approach or will start from it. For each stream the windows menu offers a choice of medium (liquid, gas, steam, etc.) and the meter type (e.g. ultrasonic, turbine, Coriolis, orifice, venturi, prover). Analysers are listed including GC s from most manufacturers. The menu guides you through selections, such as the sensors used, the type of correction, the communication, and allows you to customising the menu and the reports. It can also allow you to mimic the screen of other flow computers on your screen. Local language menus and reports are possible. Communication can be adapted to match the host requirements. The result can be sent via and/or can be loaded into the flow computer within seconds using the fast USB port.
9 Specifications. KROHNE Summit 8800 Overview Number of streams Calculation cycle Communication Audit trail/ logging Products Up to 5 runs plus a prover 1/4 second max. The Summit 8800 can handle a combination of several serial and Ethernet ports. Reports can be printed by a FTP network printer and even sent in an SMTP . Full audit trail with person ID, Logging/ trending e.g. lifetime data, recorded 7 times per minute on 4 GB memory Oil, Gas, Liquids, Steam, LPG, LNG, industrial gases, Water, CO 2 emission, etc. Hardware Chassis Power supply Operating Half width 3U high 19 construction Panel or chassis mounted Dimensions 130 x 210 x 240 mm (h x w x d) Accommodates up to 6 I/O and communication boards IP20 Ingress protection index level IP52 in a panel with open doors IP 65 in an appropriately closed panel Supply voltage 22 to 28 V DC 8.5 W (15 W fully loaded) Protection 3.15 A fuse Auxiliary Outputs 24 V 200 ma Operating Temperature C ( F) Storage Temperature C ( F) Operating Humidity to 90% non-condensing Weight approximately 2.0 kg / 4.5 lbs (2.5 kg / 5 lbs full loaded) Rear Panel Field connections Switch Panel PSU connections and fuse Six slots for option boards I/O and Communication Connections Access to Security Mode switches Access to Memory Card
10 Specifications KROHNE Summit 8800 Front Panel Display Display Various Configuration Connectors 5.7 Colour graphics screen Touch Panel 360 Rotary menu navigation Local Language Support 5 x High Brightness Indicator LED s Front Panel USB connection Menu-based configuration program Local Data Downloading via USB Local Diagnostics and...and configuration setup RS232/485 RJ45 Ethernet 10/100 Mbs RJ45 Connector kit to rail mounted screw terminal I/O board Weidmüller non-screw type 36-way Part Power in Weidmüller connector Part Power out Weidmüller connector Part Meters and Standards Meter technology Connectivity Approvals Pulse: e.g. Turbine, PD, Prover, Ultrasonic, Coriolis DP: e.g. Orifice, Venturi, Cone, Nozzle Serial: e.g. Ultrasonic, Coriolis, Turbine / Rotary Meters: Turbine, Coriolis, PD, Ultrasonic, Orifice, Venturi, Nozzle, etc. Ultrasonic meters: KROHNE, Daniel, Elster, GE, Sick, etc. Chromatographs: ABB, Daniel, Elster, Siemens, etc. Density/ specific gravity: frequencies Solartron 781x, 783x, Sarasota ID900 Provers: Bi-directional, 2 / 4 detector inputs, piston prover, master provers Control: up to 18 valves, Prover, PID Compliant with all international approvals, including - MID European approval - CSA C22.2, CB, CCSAus - UL , IEC , IEC , EN G OIML R117 - NMi metrology requirement
11 Specifications KROHNE Summit 8800 Meters and Standards (cont.) Standards Processing Compliant with international standards, including ISO 5167 (1991, 1997, 2003), ISO 6976, ISO 6578 PTZ, NX19, NX19 G9, SGERG AGA3, AGA5, AGA7, AGA8, AGA9, AGA10 API MPMS 11.1, 11.2, 21 (1952, 1980, 2004) API Chapters , , ASTM D1250 IP200 OIML R022 GPA 2172 GPA TP-15, TP-25, TP-27 GOST NX19 Calibration up to 30 points linear (positive or negative), meter factor or K-curve, 5 products Pulse handling: API5.5 level A, B, C, D, E, Dual chronometry, pulse interpolation Counters: Unhaltable, Normal, Period, Error, Maintenance, Positive and negative, Prover Averages: Time weighted, Flow weighted Redundancy Master/Slave computer Health based switching Built in redundancy system Duty-standby system based on health indicator Healthiest computer Duty Other flow computer Hot standby Health watchdog system
12 Specifications KROHNE Summit 8800 I/O Boards Type Board: Digital 1 HART transmitter loop Up to 3 transmitters (if multi-dropped) Up to 4 variables per transmitter For temperature, (differential) pressure, meters Direct PRT Input 3 or 4 wire PT100 temperature input -20 C C ( F), 100 W, 1 ma energise Analog Inputs 4-20 ma, 100 ohm, 20 bit resolution, accuracy 0.01 % 20 C 3 standard, 1 optional (instead of 1 Digital output) Selectable: either additional 1x 4-20 ma input Selectable: either 1x 4-20 ma output or 1x Digital Output Digital Inputs for Switch / Valve / Status 3 of which can be: Pulse Counting/ Frequency Inputs Digital / Switch / Valve / Alarm / Pulse Outputs Analog Outputs Selectable Digital Input or Output Serial Communication Connection * 1 input and 1 output selectable to be digital or analog Optically isolated, 24 Vdc, 25 ma DC to 10 khz, optically isolated ISO 6551 or API Chapter 5.5 Level A, B-E Turbine, density, status or detector switch max, Input voltage + 24 Vdc or 1.2 Vdc Open Collector, 30 V max, 20 ma, 100 mw Frequency 2, 5, 10, 25, 50 50% duty cycle 2 standard, 1 optional (instead of 1 Digital output) 4-20 ma, loop max. 750 W, 26 ma 16 bit max error 0.15% For telemetry and PID control Can be individually selected to be input or output Same specifications as above RS232/RS485 Speeds up to baud, software handshake Modbus Master/Slave communication For meters (ultrasonic, Coriolis), GC and analysers Digital 2 Analog Switch / 4* - 5 (3) 4 (3) 5 / 4* (3) 6 (3) / 4* / 3*
13 Specifications KROHNE Summit 8800 Communications Boards Type Board: Single Ethernet Dual Ethernet Serial Communication Connection RS232/ RS485 Galvanically isolated, Port 3: hardware handshake (RTS/CTS); Port 4/5 Software handshake Speeds up to baud RJ45 Connector Fully user configurable Modbus For DCS, Scada, GC, serial printers or RTU Ethernet Port 10/100 MHz RJ45 port with indicators IEEE Fully use configurable and programmable - Applications e.g.modbus master and slave over TCP - Remote diagnostics and configuration - Web Server functions- Network Time Protocol Capabilities Provides a redundant network Separate fiscal from maintenance data SOAP communication protocol Secure data transfer Encrypting of data no yes * 1 input and 1 output selectable to be digital or analog **Polymer coating is optional: Special coating to withstand moisture and salty mist as need to comply with OIML D11 class H2 (standard unit complies to class H1)
14 Specifications Dimensions [mm] Cable connection diagram Cable assembly, 2.5 m and rail-mounted terminal Ordering options Up to 6 slots with free choice of: A: Analogue I/O board H: HART I/O board 1 K: HART I/O board 2 S: Switch board E: Communication board: single Ethernet D: Dual Ethernet board: dual Ethernet P: Polymer-coated to withstand moisture and salty mist, complies to OIML D11 O: No cables C: Cable assembly (2.5 m) for each I/O board O-No training 1: 1 day operator training at KOG 2: 2 days engineering training at KOG VN90- # # # # # # - # # #
15 Notes
16 KROHNE 01/ All rights reserved Subject to change without notice - Errors and omissions excepted KROHNE Oil & Gas Overview Systems Flowmeters for custody transfer Liquid flowmetering systems Gas flowmetering systems Wet gas metering systems Provers & master meters Flow computing, supervisory software & analyzer management Calibration systems Tank inventory & management systems Analyzer houses and shelters Loading & off-loading systems Leak detection and localisation systems Revamps & upgrades Testing, installation, commissioning, service training Products Gas ultrasonic flowmeters for custody transfer Liquid ultrasonic flowmeters for custody transfer Mass flowmeters for custody transfer Venturis for wet gas metering Prover sphere detectors Flow computers Supervisory systems Meter validation software packages Electromagnetic flowmeters Level measuring instruments Variable area flowmeters Temperature measuring instruments Pressure measuring instruments Analyzers Vortex flowmeters Flow controllers Contact Head office KROHNE Oil & Gas KROHNE Oil & Gas B.V. Minervum ZG Breda The Netherlands Tel.: Fax: [email protected] KROHNE (Malaysia) Sdn Bhd No.F2, Block 46, Mentari Business Park, Jalan PJS 8/2, Bandar Sunway, Petaling Jaya, Selangor, Malaysia Tel.: Fax: [email protected] KROHNE Australia Pty Ltd. 5 Phiney Place Ingleburn NSW 2565 Tel.: Fax: [email protected] Global companies and representatives see
Contact. Workshop on advanced flow computing with the SUMMIT 8800. March 24 27, May 19 22, August 18 21, November 17 20 2014 in Breda, The Netherlands
Contact KROHNE 02/2014, Subject to change without notice. KROHNE Oil & Gas B.V. Minervum 7441 4817 ZG Breda The Netherlands Tel.: +31 76 711 2000 Fax: +31 76 711 2001 [email protected] www.krohne.com/summitacademy
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS
INDUSTRIAL GATEWAYS VPN S SERIAL DEVICE SERVERS 100% Made & Designed in Italy ETHERNET VIRTUAL COM TUNNELLING TCP-IP REDUNDANCY REMOTE CONTROL MODEM REMOTE ASSISTANCE WEB HMI/ SERVER SCADA VPN 3G+ SENECA
The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers
The DL8000 Preset Controller The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers Reliability, ruggedness, flexibility, and accuracy all in one package
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1
SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable
ROC800L Liquid Application Software
ROC800:SW1 Product Data Sheet D301576X012 January 2015 ROC800L Liquid Application Software The ROC800L Liquid Application Software Suite enables the ROC800 platform to perform API compliant liquid flow
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
ABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Vibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
Job Aid Pre-Installation Information S8500 Media Server
Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas
FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS Sami Halilah Dynamic Flow Computers Houston, Texas GENERAL LAYOUT This paper presents information about applications of flow computers in the oil
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
M-series Virtual I/O Module 2
DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Digital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
PRODUCT LIST Facility DDC Access WebXL DDC
PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
How To Use Safety System Software (S3)
SPECIFICATION DATA Safety System Software (S3) APPLICATION Safety System Software (S 3 ) is a robust, full featured configuration, diagnostic, programming and real-time monitoring package for integrators
HYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Z-TWS4. Multifunction Straton / LINUX Controller. www.seneca.it
Z-TWS Multifunction Straton / LINUX Controller OPC Linux High-level Control System suitable for: Energy Management (IEC 0870--0, IEC 0870--0, IEC 80) Plant automation (Straton - Soft PLC IEC -) CPU Linux-based
PRODUCT & SERVICE SUITE LACT CONTROL AND DATA MANAGEMENT
PRODUCT & SERVICE SUITE LACT CONTROL AND DATA MANAGEMENT Measurement Data: from Well to Awareness FLOW COMPUTER & LACT CONTROLLER Best-in-class Flow Computer Automatic Sampling Can Selection Intuitive
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
PLC training panel (Twido version)
PLC training panel (Twido version) User manual Name School of Trades Produced by: GJR October 2012 Colour leaves: 9 BW leaves: 2 Cover colour: White Cover image: G.J.Rogerson Acknowledgments: Much of the
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
DCS data and communication server
8 578 VISONIK DCS data and communication server PLD0.ECO/DGL PLD0.ECO/PCM Data and communication servers (DCS) are used as management station in building automation and control (BAC). With DDC technology,
4-CH Hybrid Digital Video Recorder
4-CH Hybrid Digital Video Recorder Key Features Hardware Embedded, highly-reliable standalone HDVR Supports 4-ch BNC connectors Supports dual local display (VGA and HDMI) Supports 3.5" SATA x 1 HDD Supports
Products and Solutions for the Oil & Gas Industry
Products and Solutions for the Oil & Gas Industry 2 Contents 3-7 Capabilities Measuring Solutions for Oil & Gas Understanding All Aspects of Oil and Gas KROHNE Commitment 8-17 Products Custody Transfer
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
M2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
Natural Gas Well Automation using Kingfisher RTU Products
Natural Gas Well Automation using Kingfisher RTU Products Introduction Semaphore s Kingfisher RTU products have been applied to well site installations throughout the world. The product family includes
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
EZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
4UHD. SDX-8x8. Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential
SDX-8x8 Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential K 4UHD The Smart-e SDX-8x8 features The SDX-8x8 is a professional flexible Digital
NGSS Data Consolidator (DC)
NGSS Data Consolidator (DC) The Data Consolidator (DC) facilitates system configuration, monitors network status, and supervises long-term data storage and remote data transmission. The DC consists of
Qingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge
Automatic Tank Gauging System Magnetostrictive Liquid Level Meter (Tank gauging system) for gas stations produced by Guihe consists of Probe and Touch Control Console. There are different plans to satisfy
Real-time Video Monitoring Increases the Efficiency of SCADA Process Management
Harry Hsiao, Moxa Product Manager ([email protected]) Traditional SCADA (Supervisory Control and Data Acquisition) systems have been an important part of automation control systems for many years, and
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
Versions. Q.station Q.station T. Q.station D. Q.station DT x x
Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output
Natural gas chromatograph LNG gas quality testing
Application description AD/2102760-EN Natural gas chromatograph LNG gas quality testing Introduction The portable NGC8206 is a natural gas chromatograph designed for installation in a vehicle or mounted
Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information
London Electronics Limited Warren Court, Chicksands, Shefford, Bedfordshire SG17 5QB Tel +44(0)1462-850967 Fax +44(0)1462-850968 www.london-electronics.com [email protected] Ethernet to RS232
APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700
Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 [email protected] http://www.datakom.com.tr APPLICATION NOTE Ethernet Configuration Guide for D-500 D-700 PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY:
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
AutoLog ControlMan. Remote Monitoring & Controlling Service
AutoLog 1 AutoLog ControlMan Remote Monitoring & Controlling Service Web browser based HMI / SCADA interface Server is hosted by Internet server hosting company Control units communicate wirelessly via
Take total control of your HVAC system with cost-saving flow and thermal energy meters
Take total control of your HVAC system with cost-saving flow and thermal energy meters Because you can t manage what you don t measure usa.siemens.com/pi Answers for Industry. Contents Introduction 03
Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
Modicon M340 PAC Improve process and energy management
Modicon M340 PAC Improve process and energy management Make the most of your energy SM When you need to achieve energy and productivity improvement objectives to create a single environment measuring energy
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Physical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Digital multimeters DMG 600-610
Digital multimeters DMG 600-610 Digital multimeters DMG 600-610 are capable of viewing the measurements with high accuracy on the wide LCD display, which allow to control energy distribution networks.
www.foxboro.com/instrumentation EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management
www.foxboro.com/instrumentation EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management EASY Easy to Install, Easy to Configure, Easy to Use... The features and functions of this innovative series
Introduction To SCADA and Telemetry
Introduction To SCADA and Telemetry Joe Mullaney Senior I&C Engineer MSE Technology Applications, Inc. Tetragenics Division [email protected] Overview Definitions What is SCADA? What is Telemetry?
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
Fleet Tracking Capability. FX 500 / FX 250 FleetBroadband Satellite Terminal
Fleet Tracking Capability FX 500 / FX 250 FleetBroadband Satellite Terminal Ver : 1.0 Date : 16 Jan 2013 Contents Introduction 3 Product Overview 3 Application 4 Setting Up 5-9 Technical Summary 10-11
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
DCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
Complete SCADA solution for Remote Monitoring and Control
Complete SCADA solution for Remote Monitoring and Control FF-Automation (founded 1976) manufactures AutoLog RTUs, designs and supplies complete automation SCADA solutions for remote monitoring and control
Unidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications
The systems and devices of the MODULAR I/O family are the Tecnint HTE solutions for industrial and technological application of automation, acquisition and management that require particularly robustness
Web-Based Remote Monitoring & Datalogging
Web-Based Remote Monitoring & Datalogging WebAlert WebAlert was developed to meet the increasing demands for improved operational efficiencies and enhancements to service programs that can be gained by