Make full use of equipment
|
|
|
- Jessie Dalton
- 9 years ago
- Views:
Transcription
1 otor Electronic Control and System For ultimate motor protection and increased productivity For Contactor TIP! Use Overload Relay Family CA7 CA6 CA5 CEP7 CT7 CT7K CT4 CA4 CEF1 Described in this section Detailed technical and application information can be found in publication no: Tech-NK. Ask your Sprecher + Schuh representative for a copy. The Sprecher + Schuh Electronic otor Unit is a unique digital microprocessor controlled system that creates an exact thermal image of the motor. This technology permits motors to run at their full capacity while providing maximum overload protection. Options are available that provide additional protection functions including short circuit, phase reversal, underload protection, ground fault, and much more. ake full use of equipment The provides extremely accurate thermal imaging of the motor. This means that equipment can be safely run at maximum output even with fluctuating loads, brief overloads, phase unbalance, and other conditions. The precise thermal imaging takes into account the temperature rise of the stator winding and the iron mass of the motor. This two-body simulation provides accuracy during all conditions of starting, running, and stopping motors. Simple adjustments provide accurate thermal simulation for all types of motors. Avoid unplanned downtime, diagnose problems quickly The various protective and control functions can be easily programmed to trip the main (tripping) relay, a separate alarm relay, or any of five auxiliary relays. This means that a warning can be given rather than tripping the motor off line, allowing the unit to be repaired during a planned shutdown. In addition to causing output relays to trip, all parameters can be displayed on the LCD panel located on the front of the. ➊ ➐ ➋ ➏ Use with all types of motors Adjustments can be made for different motor cooling constants, such as those found on separately ventilated or liquid cooled motors. Also, the degree of inertia setting can be changed to adapt to motors with differing locked rotor time ratings. This makes the adaptable to protecting all motors under maximum loading conditions in both high and low inertia applications. The is not directly connected to the motor voltage. ecause of this feature, and the fact that it is so flexible, it can be effectively used on medium voltage motors. For these applications, the user must supply appropriate current transformers. onitor thermal usage For increased safety and productivity, an optional 4-20 milliamp analog output is available that allows monitoring of thermal usage of the motor. When used for load control, such as a feeder conveyor on a rock crusher, the loading can be continually matched to the motor s maximum temperature. This permits optimum utilization of the motor with full thermal overload protection. ➌ ➍ ➎ 42
2 otor Wide array of standard features Thermal overload Single-phase protection Phase unbalance protection Ground fault protection Stall protection Underload protection Starting time monitor Limited starts per hour Warm start limit Emergency override Available options Short circuit Ground fault leakage Stall during start ultiple RTD temperature sensor inputs PTC thermistor input Phase sequence monitor Analog output of thermal utilization (4-20mA) Wye-Delta starting control elements (Refer to photo on opposite page) ➊ Values Actual Set ➋ Select Recorded ➌ Settings Change Enter ➍ Test ➎ Reset ➏ LCD ➐ Fault Indication Flashing Steady state Select ode Indication of actual operating data Setting mode (set/vary, store parameters) Indication of statistical data Select function to view or change Change and enter commands Enable entry emorize entry Test functions (alarm, trip, trip time, etc) Reset trips Single line (two lines are alternated) LED Warning Trip Standard protection functions Thermal Overload - Under many conditions it is only necessary to set the full load amps of the motor. The time/current trip characteristics are factory set for most motors - six times FLA for 10 seconds. In addition to setting the full load amps, five other parameters can be set. This means accurate protection for all types of motors. Phase Unbalance and Single-phase - When phase voltages are unbalanced, the resulting current unbalance in the motor can be six to ten times the voltage asymmetry. These currents can quickly cause damage to the motor. The can provide warning and trip functions for current imbalances of 5 to 80%, with tripping delay adjustable from one to five seconds. High Overload and Stall - When motor driven machinery becomes blocked or jammed, unnecessary motor temperature rise and mechanical damage can result. The can provide tripping or alarm signals under these conditions. The stall current is adjustable from one to six times full load amps and the trip delay can be set from 0.1 to 5 seconds. Since the motor has not experienced a significant temperature rise, it can be restarted immediately after the blockage has been removed. Underload - Pump motors that are cooled by the medium they are pumping can be overheated in spite of underloading. Also, pumps can be damaged by cavitation or noload pumping. On other equipment, broken shafts, belts etc., can cause severe damage quickly. Very often, these motors are only accessible with difficulty, so any damage would cause long and costly repairs. The can detect underload conditions and provide warning or trip. The response level is adjustable from 0% to 100% of FLA. The time delay is adjustable from 1 to 60 seconds after the motor current has fallen below the set response level. Ground Fault - ost insulation faults in motors result in small ground currents which can rapidly rise to a very high value causing motor failure. The can be set to trip or provide warning of ground currents of % of FLA, with a time delay of 0.1 to 5 seconds. For even greater protection, the CST4 option is available which can utilize a 100/1 ratio core balance current transformer to detect ground currents as small as amps. This can provide early warning to protect against motor damage from ground faults. Other important functions Limited starts per hour - Total number of starts per hour can be limited from 1 to 10. onitor starting time - aximum starting time of the motor can be set from 1 to 240 seconds. Warm start - If desired, tripping time for a warm start can be extended to % of the cold start setting. The number of warm starts per hour can be set from 1 to 15. Emergency override - Allows the motor to be started immediately after tripping. Can be used in situations where continuing operation is more important than motor protection. rear view 43
3 otor Optional protection functions The following warning and protection functions are available options: Short Circuit - Enables fast tripping under short circuit conditions. Setting range adjustable from 4 to 12 times FLA, delay adjustment is 20 to 990 milliseconds. Stalling During Start - Provides an input connection for a zero speed switch to sense motor stall during start and trips in 1/2 second. Thermistor (PTC) Input - Allows connection of thermistors embedded in motor windings to trip under overtemperature conditions. Control Inputs - Two external input connections can be programmed to provide a variety of programmed functions such as timers, lock out of protection functions and two speed starting. Timer Functions - 0 to 240 second on and off delay timers can be initiated by external control inputs and programmed to output relays. Intuitive controls provide easy operation The is very easy to operate. Utilizing six pressure sensitive keys and the LCD, all functions, data and tests can be entered, executed, or displayed. SET VALUES Actual Recorded Values Set Communicate! Change Enter Select Settings An optional communications card is available that provides connectivity to the outside world. Utilizing the internationally recognized PROFIUS communications protocol, this provides two way communications to program the and There are three program modes: Set Values, Actual Values Recorded Values Each is selected in rotation by pressing the Values button. Once the desired mode is reached, all of the related functions can be easily viewed or set from the front panel. All LCD information is in plain English, no reference charts are needed to decipher codes. Although the can be elaborately programmed to provide specific protective functions, often the factory settings are adequate. In that case, you need only to set the full load amps (FLA) to put the unit in service. monitor real-time as well as historical data. ultiple units can be connected in a network system along with PLC s and personal computers. Additional hardware and software is required. Communications cards are also available from third party sources for other communication protocol standards. Phase Sequence - Prevents equipment damage due to accidental reversal of phases. CET 4 CET 4 CET 4 CET 4 CET 4 Up to 30 s can be connected together Phase Failure (voltage) - Standard phase failure feature monitors phase currents. This feature monitors phase voltage and will not allow an attempted start during a phase failure. Wye-Delta Starting - Provides the signal to switch from wye to delta by monitoring motor current. RTD Temperature Sensors - Connect up to 6 resistance temperature detectors (RTD s) for continuous monitoring of stator or bearing temperature and 1 RTD for monitoring of coolant or ambient temperature. Can be programmed for warning and/or trip. No.1 No.2 No.3 No.4 Ideal companion for Softstarters Solid state reduced voltage starters on large HP motors often have special requirements for overload protection. The can be a perfect solution because its trip characteristics can be matched exactly to the motor, equipment, and starting parameters. In addi- tion, the numerous protective and warning features of the can provide an added degree of safety and reliability. Features such as ground fault, phase failure, and the ability to connect external RTD s embedded in the motor can be especially important. See Softstarters in this catalog for detailed information. 44
4 otor Electronic Control and System Type Electronic Unit, Options & Accessories Price Description Catalog Number (or Suffix) (or Adder) Electronic Unit For connection to converter module CWE4 Functions of basic unit include: Thermal overload protection Single phase protection Stall protection Underload protection Ground fault Starting time monitor Limited starts per hour For flush mounting in panel ➊ - -V50/60 ➋ 2544 Options ➌ Functions of CST4 option: Short circuit Ground fault leakage (requires core balance C.T.) Stall during start Thermistor input (PTC) Analog output for thermal utilization -S 657 Functions of CLV4 option: Wye-Delta starting Single phase protection (motor supply) Phase sequence -L ➍ 445 Functions of CV4 option: PT 100 inputs #1 #6 (stator/bearings) PT 100 input #7 (ambient temperature) - ➍ 637 Functions of CP4 option: PROFIUS communications interface -P 828 Accessories Indication instrument for motor temperature rise CUD4 445 ase ounting Frame CP4 198 PC Option Set (communications card and software for a PC) CPC4 891 Core alance Transformer - ratio 100/1 CTO4 540 For accurate sensing of ground currents from 0.5 to 10 Amps CWE Converter odules and Accessories ➏ Current Range Primary Connections Catalog Number Price Amps ➐ Saddle clamp, up to 12 AWG (4mm 2 ) wire CWE Amps ➐ Saddle clamp, up to 12 AWG (4mm 2 ) wire CWE Amps Feed through window opening (19mm) or bus bars (20 x 4mm) CWE4-180 ➑ Amps us bars (25 x 8mm) CWE Accessories Conductor ars for CWE4-180 Universal connections for separate mounting- Terminals: 8 (4 x 16 x 100 mm); Rated to 125A CWE4-V 60 ➒ Universal connections for separate mounting - Terminals: 8 (4 x 20 x 117 mm); Rated to 180A CWE4-V2 88 ➒ For mounting to CA6-85 and CA6-105 contactors - Terminals: bottom 6 / top ø7; Rated to 125A CWE4-VS 60 ➒ For mounting to CA6-140 and CA6-170 contactors - Terminals: bottom 8 / top ø8.5; Rated to 180A CWE4-VS2 120 ➒ Ordering Example Specification: Electronic otor Unit with CST4, CLV4 and CP4 options and a supply voltage of 240VAC/60Hz. For a 100 HP motor 460VAC/60Hz (120 FLA). Communications with PC. ➊ For base mounting, order ase ounting Frame CP4 separately. ➋ Replace in catalog number with AC supply voltage code: 120, 240, or 440, or DC code: 24VDC, or 48VDC. Other voltages consult factory ➌ All options must be factory installed. ➍ The CLV4 option and CV4 option occupy the same slot, therefore only one can be installed. ➎ must have the CP4 option to utilize this accessory. Ordering Specification: One (1) -230V50/60-S-L-P (Electronic Unit) One (1) CPC4 (PC Option Set) One (1) CWE4-180 (Converter odule) One (1) CWE4-V2 (Conductor ar with universal connections) ➏ ounts on DIN-rail (or base mount) inside panel behind, or directly to contactor. ➐ Up to 630 Amps when using primary current transformers. ➑ Order bus bars for CWE4-180 separately (see CWE4 Accessories). ➒ Three bus bars per package. Price per package. 45
5 Technical Information Electronic Control and System otor Overview of Functions Protective Functions Function Trip Relay Factory Setting Factory Delay Factory Selection Factory Setting range Setting Range Setting Choices Setting ➊ asic Unit Thermal overload On R R Phase unbalance/failure (% of FLA) On 5-80 % 35 % 1-5 s 2.5 s All R Stalling/high overload (mulitple of FLA) On 1-6 x FLA 2.4 x FLA s 0.5 s All R Underload (% of FLA) Off % 75 % 1-60 s 10 s All R Underload delayed enable On s 0 s - - Ground fault (% of FLA) On % 50 % s 0.5 s All R Starting time monitor Off s 10 s All R Limited starts per hour Off All R Option CST4 Short Circuit (% of FLA) Off 4-12 x FLA 10 x FLA ms 50 ms #1 #1 Ground Fault (core balance c.t.) Off ma 5 ma s 0.5 s All R Stalling during start (external input) Off All R Thermistor input (PTC) Off ms R R Option CLV4 Phase sequence - motor supply Off s All R Phase failure - motor supply Off s All R Option CV4 RTD temperature detectors #1 - #6 (stator, bearings) Off o C 50 o C - <8 s R, AL, #1-3R RTD temperature detector #7 (ambient) Off Warning Functions asic unit Thermal utilization (% of thermal limit of motor) Off % 75 % - - AL, #1-5 AL Phase unbalance (% of FLA) Off 5-80 % 20 % - - AL, #1-5 AL Stall/high overload (% of FLA) Off 1-6 x FLA 2 x FLA - - AL, #1-5 AL Underload (% of FLA) Off % 75 % - - AL, #1-5 AL Option CST4 Ground fault (core balance c.t.) Off ma 5 ma - - AL, #1-5 AL Option CV4 RTD temperature detectors #1 - #6 (stator, bearings) Off o C 50 o C - - AL, #1-5 AL Time/Current Characteristic t A I e a b C Tripping time in seconds Rated service current of the motor = I ef Locked rotor current; setting range I A = I e Inertia: Setting range with appropriate set locked rotor current t IA = sec The setting of I A /ti A must be outside this range (e.g. when I A = 6 x FLA, ti A must be 100s) C ➊ Only one relay per fuction can be selected: R = ain Relay, AL = Alarm Relay, Auxiliary Relays #1 - #5. 46
6 otor Technical Information Electronic Control and System Overview of Functions Control Functions Function Trip Relay Factory Setting Factory Delay Factory Selection Factory Setting range Setting Range Setting Choices Setting ➊ asic Unit Warm start (% of cold trip) Off % 70% 4-60min 60min - - Emergency override of thermal trip Off Connect terminals Y11 and Y Option CST4 Analog output of thermal utilization On 4-20mA Control Input #1: (24 VAC/DC; 8mA) Select one of the following two functions: Function #1 - timer function Pickup Delay Off s 1s - #2 Dropout delay Off s 2s - #2 Function #2 - disable protective functions Phase unbalance/failure Off Stall/high overload` Off Ground fault Off Short circuit Off Underload Off Limit starts per hour Off Thermistor (PTC) Off RTD temperature detectors Off Control Input #2: (24 VAC/DC; 8mA) Select one of the following three functions: Function #1 - timer function Pickup Delay Off s 1s - #3 Dropout delay Off s 2s - #3 Function #2 - set second current rating (2 speed motors) Thermal overload Off A 20A Function #2 - disable protective functions Phase unbalance/failure Off Stall/high overload` Off Ground fault Off Short circuit Off Underload Off Limit starts per hour Off Thermistor (PTC) Off Option CLV4 Wye-Delta starting Off x FLA 1-240s 10s
7 Technical Information Electronic Control and System Technical Information otor Rated Operating Voltage UL/CSA With CWE4-2.5 current module [V] 240V With CWE4-20 and higher current module [V] 600V IEC, SEV, VE 0660 With CWE4-2.5 current module [V] 400V With CWE4-20 current module [V] 660V With CWE4-180 & CWE4-630 current module [V] 1000V Supply Voltage AC - 50/60Hz [V] 110V, 220,- 240V, V, 440V DC [V] 24-48V Permissible Fluctuation AC [%] 0.85 to 1.10 of rated supply voltage DC [%] 0.80 to 1.10 of rated supply voltage Power Consumption AC [VA] 13VA DC [watts] 10 watt maximum Control Circuits ain Relay (R) - 1NO & 1NC contact, galvanically separated Nominal voltage rating - UL/CSA [V] 240VAC Nominal voltage rating - IEC 947 [V] 400VAC Current Ratings UL/CSA pilot duty, 240V [A] 4 Amps 24V 48V 60V 110V 220/230V 240V 380V 415V 440V AC Rated Service Current 4A 4A 4A 4A 3A 3A 2A 2A 1.5A DC Rated Service Current without protection network, L/R=35ms 0.6A 0.3A 0.25A 0.15A 0.05A 0.05A with protection network, L/R=100ms 0.6A 0.6A 0.5A 0.5A 0.5A 0.5A aximum permissible switching current 44A 44A 44A 44A 33A 33A 22A 22A 16.5 Alarm Relay & Auxiliary Relays #1, #4, #5-1NO contact Nominal voltage rating - UL/CSA [V] 240VAC Nominal voltage rating - IEC 947 [V] 400VAC Continuous thermal current [A] 4A aximum permissible switching voltage [V] 400VAC, 30VDC Nominal service current - resistive [A] 4A at 250VAC or 30VDC Nominal service current - inductive, 0.4p.f., L/R=7ms [A] 2A at 250VAC or 30VDC aximum switching power, resistive load 1250VA, 150W aximum switching power, inductive load, 0.4p.f., L/R-7ms 500VA, 60W Auxiliary Relays #2, #3-1 N.O contact Nominal voltage rating [V] 50VAC, 30VDC Continuous thermal current [A] 4A aximum permissible switching voltage [V] 48VAC, 30VDC aximum switching power, resistive [W] 150W aximum switching power, inductive, 0.4p.f., L/R=7ms [W] 60W Control inputs #1, #2 Nominal voltage rating [V] 24VAC, 24VDC Temperature Normal operation [ C] -5 o C to +60 o C For transport [ C] -40 o C to +60 o C For storage [ C] -40 o C to +60 o C Climate Humid heat IEC o 92% relative humidity (56 days) Alternating climate (21 cycles) IEC o 80% relative humidity/40 o 92% relative humidity Degree of protection, enclosed in panel IP 65 Terminals IP 20 Resistance to vibration - IEC Resistance to shock - IEC Hz, 3g 30g shock for 18ms, semisinuisoidal in x, y, z directions 48
8 90 otor Technical Information Electronic Control and System Technical Information (continued) Electrical Tests otor Circuit Impulse Test - per IEC with CWE4-2.5 converter module [kv] 2.5 kv with CWE4-20 converter module [kv] 6 kv with CWE4-180 or CWE4-630 converter module [kv] 8 kv Control Circuit Impulse Test per IEC ain Relay (R), phase Sequence protection L1, L2, L3, Alarm Relay (AR), Auxiliary Relay #1, #2, #3 and between control circuits and all other circuits ➊ 4 kv Core balance current transformer k, l, Control Inputs #1, #2, Auxiliary Relay #2, #3 [kv] 2.5 kv EC Standards Noise emission EN and EN Noise proof EN and EN Terminals Power Terminals CWE4-2.5, CWE4-20 [AWG] One #20 to #12 AWG or two #20 to #14 AWG [mm 2 ] (metric: one 4 mm 2 or two 2.5 mm 2 ) CWE mm opening for wire pass through or 20/16 x 4 mm bus bar CWE4-630 bus bar 25x8 mm Control Terminals Wire size, UL [AWG] #22 - #14 AWG Wire size, VDE [mm 2 ] 1.5 mm 2, nominal Cross section range - single wire [mm 2 ] mm 2 Cross section range - two wires [mm 2 ] mm 2 External Current Transformers When using the as a secondary relay with current transformers, use CWE4-2.5 or CWE4-20 Converter odules Recommended External C.T. Specifications: inimum nominal service voltage Same as motor inimum rated primary current Same as motor Rated secondary current [A] 1A or 5A urden +CWE CWE4-20 Power consumption at rated current [VA] 0.1 VA/phase 0.4VA/phase Thermal limit current continuous [A] 3A 24A Thermal limit current 1 second [A] 250A 600A Frequency of input current 50/60Hz 50/60Hz Weights with power supply module [g] 1000g Option CP4 [g] 125g Options CST4, CLV4, CV4 [g] 90g ounting Position ➊ The measuring inputs for RTD and PTC inputs, the 4-20ma output, and the RS485 interface are not isolated from one another. 49
9 Technical Information Electronic Control and System Wiring Diagrams INCOING POWER L1 L2 L3 INCOING POWER L1 L2 L3 L1 L2 L3 L1 L2 L3 FIG. 1 FIG. 1 (OPTIONAL) otor H1 H4 H1 H4 CO. FUS./NON FUS. DISC. SEE FIG. 1 CO. CP SEE FIG. 1 1L1 3L2 5L3 CWE 4 2T1 4T2 6T3 T1 T2 T3 TR CET 4 T1 T2 TR T3 3 CT's 1L1 3L2 5L3 CWE 4 2T1 4T2 6T3 CET 4 Variants: - Two-phase current evaluation - Two-phase current evaluation and earth-fault protectio with core balance transformer Converter module CWE CWE 4-20 ain current transformer...a / 5 A or...a / 1 A For selection see <<Technical Data>> NON COINATION NON COINATION LI(XF) 230V 480V 23 LINE HI H4 HI H4 LI(XF) STOP OFF HAND AUTO JUPER H1&H3 H2&H4 H2&H3 START START-STOP PUSHUTTONS RCD HAND-OFF-AUTO SELECTOR SWITCH H1 H3 H2 H4 CCT FU 230/480V 24/120/208V (OPTIONAL) XF X1 X2 X1 X1 RUN R A1 A2 (A) () A RUN R A1 A2 (A) () A X2 TRIPPED X2 TRIPPED A1 A1 CET 4 C CET 4 C A2 A2 L2(X2) L2(X2) Terminals asic Unit CET 4 Supply Emerg. Start Remote Reset Remote Reset Alarm Relay AL A1 - A2 + Y11 Y12 Y13 Y21 Y ain Relay R Non-Fail-Safe Fail-Safe NOTES: 1). CONTACTS ARE SHOWN IN THE READY STATE WITH CONNECTED SUPPLY VOLTAGE PRESENT. (FACTORY SETTING: FAIL-SAFE ODE) 2). RCD: STANDS FOR REOTE CONTROL DEVICE Y CUSTOER. 3). X2 TERINAL GROUNDED AS STANDARD, REOVE IF NOT REQUIRED
10 otor Technical Information Electronic Control and System Wiring Diagrams Terminals asic Unit CET 4 Option CST 4 Supply: Emerg. Start Disable Settings Remote Reset A1 - A2 + Y11 Y12 Y13 Y21 Y22 Supply AC or DC No fuse required Emergency override of thermal trip (emergency start): Pushbutton, key switch Disable setting: Wire jumper, switch, key switch Remote Reset: Pushbutton, key switch A ma ( ohm) Aux Relay # 1 Aux Relay # 2 Aux Relay # 3 I+ I- Auxiliary relay # 1 IEC 400 VAC / 125 VDC UL / CSA 240 VAC / 125 VDC Auxiliary relay # 2 50 VAC / 30 VDC Auxiliary relay # 3 50 VAC / 30 VDC Analogue output to determine the thermal utilization of the motor (indicating instruments, PLC input, recorder) Alarm relay AL IEC 400 VAC / 125 VDC UL / CSA 240 VAC / 125 VDC Output relay R in fail-safe connection (factory setting) IEC UL / CSA 400 VAC / 125 VDC 240 VAC / 125 VDC Control Input # 1 Control Y41 Control input # 2 Input # 2 Y42 24 VAC/DC PTC Y31 Y32 T1 T2 Control input # 1 24 VAC/DC Thermistor overtemperature protection max. 6 PTC wired in series easuring lead: Cross-section [mm^2] 0.5 ax. length [m] External Internal Output relay R in non-fail-safe connection IEC 400 VAC / 125 VDC UL / CSA 240 VAC / 125 VDC L1 L2 L3 External k l Core balance transformer ma Internal Option CLV 4 F Aux Relay # 4 Aux Relay # 5 L1 L2 L3 Auxiliary relay # 4 IEC 400 VAC / 125 VDC UL / CSA 240 VAC / 125 VDC Auxiliary relay # 5 IEC 400 VAC / 125 VDC UL / CSA 240 VAC / 125 VDC Phase sequence protection Phase failure protection IEC / SEV VAC UL / CSA VAC Option CV 4 1T1 PT 100 #1 1T3 1T2 2T1 PT 100 #2 2T3 2T2 3T1 PT 100 #3 3T3 3T2 PT 100 inputs #1...#6 for monitoring the temperature of the stator winding and motor bearings. 4T CWE 4 PT 100 #4 4T3 4T ~ 6 PT 100 #5 5T1 5T3 5T2 PT 100 inputs #7 for indication of and allowance for the coolant / ambient temperature (cooling air) in the thermal facsimile 6T CWE ~ T F External L1 L2 L3 Supply voltage > 400 VAC (UL / CSA 240 VAC) with voltage transformer Internal PT 100 #6 PT 100 #7 External 6T3 6T2 7T1 If the PT 100 inputs #7 is not connected, then a resistor of 7T3 120-ohm must be connected 7T2 instead the sensor (T1-T3 must be shortend). Internal easuring Leads Up to 10 m: no screening/shielding (separated from power c Longer leads: screened/shielded - separately screened -> connect screen to T2 - common screening -> connect screen to xt2 51
11 Dimensions Electronic Control and System Electronic otor Protector and CP4 ase ounting Frame Dimensions are in millimeters Dimensions not intended for manufacturing purposes max. 6 mm 10 max ø 6.5 otor sprecher+ schuh Alarm Trip Actual Test Values Select Settings Reset Recordet Set Change Enter CET max. 159 CWE4 Converter odule ø d ø e d3 b b d3 b (panel mounting shown) Side view CP4 ase ounting Frame ø e ø d d1 1) d1 e2 d2 a e2 c1 c 2) e2 d2 a e2 ø e1 c1 c CWE4-2.5 CWE4-180 CWE4-630 Type a b c c1 ød d1 d2 d3 øe øe1 e2 CWE x4mm CWE x4mm CWE ➊ ➊ 38.5 CWE ➊ See us ars in CWE Converter odule Accessories section (page 45). 52
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
How To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications
The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible
*.ppt 11/2/2009 12:48 PM 1
Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Number 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Speed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Softstarters Type PSR
Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
Heavy Duty Control. Catalog Numbering System. General 8/47. Siemens Industry, Inc. Industrial Controls Catalog. 48 Overload Size
Heavy Duty Control Catalog Numbering System 48 Overload Size A B Frame A Frame B T ESP200 3 3 Phase Single Phase 00,, 20 or 30 Selectable Current Range A 0.2 B 0.7 3.4 Reset C 3 2 D. 22 E 40 F 3 2 G 2
Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz
Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Technical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Products and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
Panorama. Softstarters The complete range
Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
BIG SAVINGS FOR A LOT MORE APPLICATIONS
MSF SOFT STARTERS BIG SAVINGS FOR A LOT MORE APPLICATIONS Soft Starters from Emotron Unique features built into Emotron MSF Soft Starters reduce costs significantly for many more applications when compared
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
BETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Data Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many