EntreMatic EMSW Installation manual

Size: px
Start display at page:

Download "EntreMatic EMSW Installation manual"

Transcription

1 EntreMatic EMSW Installation manual AAE274 TB2 Motor control 0 V DC "Slave" control 24 V DC LK LSC HSC HSC LSC LK 701??? HSO LSO HSO LSO 701??? 1234 TB1 0 V DC Impulse Lock 24 V DC (+)13-20 V DC Kill TB AAF293EMA FAA074F0EMEI Issued

2 2 Issued FAA074F0EMEI

3 Table of content: 1. Revision Important information Introduction Function description Technical specifications Models EMSW, standard cover wall mounted EMSW-SPEC, cover with optional length (wall-mounted) EMSW-2, double door operators Part identification & Accessories Further Accessories Mechanical installation Wall-mounted operator with arm system PUSH Establish the installation height Mounting the drive unit Mounting the door fitting with telescopic part Mounting the drive arm Adjusting the arm system Checking the door movement Wall mounted operator with arm system PULL / PULL-P Changing the direction of rotation Establish the installation height Mounting the drive unit Mounting the drive arm and door fitting Checking the door movement Electrical connection Control units Connection of control unit CSDA single doors Connection of control units CSDA and CSDA-S double doors Start-Up Connection of activation units and accessories FAA074F0EMEI Issued

4 Table of content: 11. Cover Fitting and removing the cover Troubleshooting Installation examples Issued FAA074F0EMEI

5 Revision 1.0 Revision Following pages have been revised: Page Revision 26 Note 3 added for Kill switch FAA074F0EMEI Issued

6 Important information 2.0 Important information Important notice! To avoid bodily injury, material damage and malfunction of the product, the instructions contained in this manual must be strictly observed during installation, adjustment, repairs and service etc. Only EntreMatic trained experts should be allowed to carry out these operations. Radio and television reception This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio and television reception. It has been designed to comply with the emission limits in accordance with EN (US market FCC Part 15) which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient the receiving antenna. Relocate the receiver with respect to the equipment. Move the receiver away from the equipment. Plug the receiver into a different outlet so that equipment and receiver are on different branch circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. Note! Instructions, design, specifications and illustrations which are contained in this manual are not binding. Rights reserved for changes without previous notice. 6 Issued FAA074F0EMEI

7 Introduction 3.0 Introduction This manual contains the necessary details and instructions for the installation, maintenance and service of the EntreMatic EMSW. The EntreMatic EMSW is suitable for most types of external and internal swing doors. The operator can be mounted to walls on either side of the door for pull or push action and is suitable for single or double doors fitted with butt hinges or pivots. It can also be installed on the door leaf. The motor, oil pump and hydraulic unit are combined into a compact unit mounted alongside the control unit within the cover. The operator is connected to the door leaf with either pushing or pulling arm systems. FAA074F0EMEI Issued

8 Function description 4.0 Function description The EntreMatic EMSW works electro-hydraulically. It opens with an AC-motor that via a hydraulic unit and an arm system transmits the power to the door leaf. The closing power is from a coil spring. The movement of the door is controlled by limit switches and valve screws. Opening When an opening impulse is received by the control unit, the motor starts and the hydraulic unit rotates the drive shaft and arm system (door) with high speed towards open position. Before fully open position the speed is reduced to low speed. The door stops and the motor rotation ceases when the selected door opening angle is reached. This open position is kept by a hydraulic valve. Closing The spring closing starts when the hold open time has run out. Before fully closed position the speed is reduced to low speed, which will be kept until the door is completely closed. The door is kept closed by spring power. To overcome the resistance of a striking plate a lock kick can be adjusted to required level. 8 Issued FAA074F0EMEI

9 Technical specifications 5.0 Technical specifications Mains power supply: Power consumption: Auxiliary voltage: Motor fuse F1: Motor fuse F2: Recommended max. door weight: 230 V AC +6/-10 %, 50 Hz fuse 10 A Note! Swich with clearly marked off-position, having a contact separation of at least 3mm in all poles, must be incorporated in the fixed wiring. The operator can also be plug-connected to a wall socklet. max. 230 W V DC, 275 ma 24 V DC, 375 ma (stabilized) 6,3 AT 250 mat Arm system PUSH: 250 kg for door leaf width 1600 mm Arm system PULL / PULL-P: 100 kg for door leaf width 1400 mm (higher door weights on request) The EMSW complies with Controlled door closing, EN 1154 size 3-6 the door weights/widths Electrically powered hold-open device for swing doors, EN stated in the: 1155 Coordination unit for rebated doors, EN 1158 Türschliesser mit Öffnungsautomatik (Drechflügelantrieb), DIN AU Grösse 3-6 Ambient temperature: -15 C to +50 C Dimensions: EMSW Standard cover Length: 716 mm. EMSW-SPEC mm EMSW mm Height: 110 mm Depth: 110 mm To be installed internally or externally with suitable weather protection. FAA074F0EMEI Issued

10 Models 6.0 Models Three main models of the EntreMatic EMSW is available: EMSW, standard cover EMSW-SPEC, cover with optional length EMSW-2, double door operators The operators are non-handed and not dependent on the hinges. The operators suit both pushing and pulling arm systems. 6.1 EMSW, standard cover wall mounted EMSW is the standard operator. Pushing arm system on a wall-mounted and on a door leafmounted operator shown. Wall-mounted AAF304EMA 10 Issued FAA074F0EMEI

11 Models 6.2 EMSW-SPEC, cover with optional length (wall-mounted) The designation EMSW-SPEC means that the operator carries a cover with optional length e.g. with the same width as the door. The length L and the cut-out R or S (for right side) must be specified in the order. Pushing arm system shown. L R 210 AAF273EMA 6.3 EMSW-2, double door operators The designation EMSW-2 means that two operators are mounted under the same cover to open one door each. The length L and the cut-outs R and S must be specified in the order. Pushing and pulling arm system shown. It is also possible to use two pushing or two pulling arm systems. L R 210 AAF274EMA S 210 FAA074F0EMEI Issued

12 Part identification & Accessories 7.0 Part identification & Accessories 8 TB2 Motor control 0 V DC "Slave" control 24 V DC 1234 TB1 AAE274 0 V DC Impulse Lock 24 V DC (+)13-20 V DC Kill LSC LK HSC LSC HSC HSO LSO HSO LK C L1 C L LSO TB AAF291EMA 12 (1) Mounting plate (2) Motor/pump (3) Magnetic Valve (4) Hydraulic unit (5) Drive shaft (6) Spring tube (7) Cable inlet (8) Mains connection (9) Control unit, CSDA (10) End plate (11) Programme selector, PS-3A (12) Cover (13) Bearaing (14) Cable holder = Centre line, drive shaft = Centre line, hinge C L1 C L2 Arm system, PUSH (Art. No BK) This arm system is delivered with drive arm, telescopic part and door fitting. They are used if the operator is installed on the wall on the opposite side of the door swing and approved for fire door applications. Arm system, PULL,Art. No BK This arm system is delivered with drive arm, guide shoe and door fitting. It is used if the operator is installed on the wall on the same side as the door swing, i.e. the door is pulled open. Arm system, PULL-P,Art. No BK This arm system is delivered with drive arm, guide shoe and door fitting with break-out unit. It is used if the operator is installed on the wall on the same side as the door swing and break-out unit is required. 12 Issued FAA074F0EMEI

13 Part identification & Accessories 3-Position Switch PS-3A Door stop Art. No Tool kit to change rotation direction Art. No Limit Switch Art. No Art. No Coordination unit, COOA Art. No PULL-Arm Reveal Spacer Art. No BK for PULL Art. No BK for PULL-P Drive Shaft Extension Kits Programme selector PS AAF272EMA Art. No Art. No Art. No Art No PUSH, Arm Extensions Reveal Up to 4-3/ mm 4-3/8 to 9-1/ mm 9-1/4 to 14-1/ mm 14-1/8 to mm Extension None (Standard arm) 345 mm 230 mm + Joint part 345 mm + Joint part 345 mm extension Art. No mm extension Art. No Joint part Art. No FAA074F0EMEI Issued

14 Part identification & Accessories 7.1 Further Accessories Mounting plate For reinforcement of the wall: 160 x 8 mm (Art. No ) Heavy duty pulling arm system ST-V/H Activation units see separate installation instructions Drilling template (Art. No ) Push & Go (PAG) (Art. No ) 14 Issued FAA074F0EMEI

15 Mechanical installation 8.0 Mechanical installation This instruction comprises the installation of the EntreMatic EMSW with arm systems PUSH which push the door open and PULL which pull the door open. Always make sure, before commencing the installation, that the door leaf and the wall are properly reinforced at the fixing points. Base material Minimum requirements Steel 5 mm * Aluminium 6 mm * Reinforced concrete min. 50 mm from the underside Wood 50 mm Brick wall Expansion shell bolt, min M6x85, UPAT PSEA B10/25 min. 50 mm from the underside * Thinner wall profiles must be reinforced with rivnuts Tools required Torx T10, T20 and T25 Metric hexagonal key 3, 4 and 6 mm Flatblade screwdriver, small Torque wrench with metric Allen socket 6 mm Drilling template Installation on double doors If the operators are to be mounted at the same height with pushing and pulling arm systems, the height is determined by the pulling arm system, PULL. The pushing arm system PUSH must always have a shaft extension, minimum 50 mm. Example: if PULL has a 20 mm extension, the PUSH must have a 70 mm extension. For installation follow the instructions for the applicable arm system. FAA074F0EMEI Issued

16 L F2 F1 N TYPE /99 LSO LSC LK LK Mechanical installation 8.1 Wall-mounted operator with arm system PUSH Establish the installation height Establish the installation height X which is the distance from the underside of the wall to the underside of the mounting plate. Mark distance X on the wall. X can be between 2 87 mm depending on the shaft extension used; none, 20, 50 or 70 mm (2 mm achieves a flush unit when cover is mounted) Mounting the drive unit 1 Put the template to the wall aligned with the hinges and with the underside of the mounting plate aligned with the mark on the wall. 2 Ensure that the template is perfectly horizontal. Drill the six mounting holes. 3 Remove the template. 4 Mark and drill the two holes for the door fitting. 5 Tap, plug or reinforce with rivnuts. 6 Fix the drive unit Mounting the door fitting with telescopic part 1 Remove the door fitting from the arm system. 2 Screw the door fitting to the door leaf tight. Y 80 (3 5 / 32 ") C L 1 = C L 2 = Extension Hinge centre line Drive shaft centre line X max. reveal 130 mm (5 3/32 ) C L 1 C L (4") 217 (8 17 / 32 ") Extension X Y None 2 17 ( 3 / 32 "- 11 / 16 ") 50 (1 31 / 32 ") ( 3 / 32 "-1 15 / 32 ") 70(2 12 / 16 ") ( 3 / 32 "-2 21 / 32 ") 100(3 30 / 32 ") ( 3 / 32 "-3 7 / 16 ") 120(4 23 / 32 ") HSO HSO LSO PUSH LSC HSC HSC Landskrona Sweden Factory No. 1 SITAC1422 EN ISO 9001 Certificate No: PowerSwing ART. NO. WEEK SERIAL NO. BATCH NO. VAC A Hz F2 = F1 = WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE ONLY WITH THE SAME TYPE AND RATING OF FUSE. 80 (3 5 /32") PUSH X X 250 (9 27 / 32 ") 45 (1 25 / 32 ") AAF315EMA 16 Issued FAA074F0EMEI

17 Mechanical installation Mounting the drive arm 1 Mount the drive arm and adaptor on the operator drive shaft at an angle of 90 to the wall. 2 Ensure that the teeth of the adaptor engage fully with the operator shaft but especially with the drive arm, so they are not damaged when the drive arm is tightened. Tighten the screw to a torque of 25 Nm. (1) Adaptor (2) Drive arm Adjusting the arm system 1 Open the door and connect the door fitting with the drive arm (do not tighten the lock screws). 2 Close the door and keep it closed. 3 Turn the drive arm until the telescopic part is at an angle of 90 to the door. 4 Tighten the telescopic part with the lock screws. (1) Telescopic part (2) Drive arm Checking the door movement Open the door by hand to its maximum extent. Then let it close of its own accord. Check that the opening/closing movements are smooth and free. Continue on page 18 for electrical installation. FAA074F0EMEI Issued

18 Mechanical installation 8.2 Wall mounted operator with arm system PULL / PULL-P If the operator is not ordered as an operator package with arm system PULL / PULL-P the direction of rotation must be reversed Changing the direction of rotation 1 Mount the washers and screws in the drive shaft, one from each side. 2 Dismantle the screws (4 pcs) from the bearing sleeves on both sides. 3 Fit the tools in the holes, one from each side and turn both bearing sleeves simultaneously approx. 165 until the setting lines in the bearing sleeves are aligned with the setting lines in the housing. 4 Remount the four screws in the bearing sleeves and dismantle the washers and screws. (1) Washer and screw (2) Screw (4 pcs) (3) Bearing sleeve (2 pcs) (4) Tool (5) Setting lines 18 Issued FAA074F0EMEI

19 L F2 F1 N 00 LK LK Mechanical installation Establish the installation height Establish the installation height Z which is the distance from the top of the door to the underside of the mounting plate. Mark distance Z on the wall. Z can be 46, 66, 96 or 116 mm depending on whether a shaft extension is used or not Mounting the drive unit 1 Put the template to the wall aligned with the hinges and with the underside of the mounting plate aligned with the mark on the wall. 2 Ensure that the template is perfectly horizontal. Drill the six mounting. 3 Remove the template. 4 Mark and drill the twoholes for the door fitting. 5 Tap, plug or reinforce with rivnuts. 6 Fix the drive unit and the door fitting. Extension 80 (3 5 / 32 ") Drive arm 23 ( 29 / 32 ") Z min. 30 (1 3 /16") C L1 C L (4") 217 (8 17 / 32 ") C L 1 = C L 2 = Hinge centre line Drive shaft centre line max. reveal 130 mm (5 3/32 ) Extension Z None 46 (1 13 / 16 ") (2 19 / 32 ") Guide shoe Door fitting Reveal spacer 40 x 60mm (1 37 / 64 " x 2 23 / 64 ") (3 25 / 32 ") WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE ONLY WITH THE SAME TYPE AND RATING OF FUSE. F2 = F1 = SERIAL NO. BATCH NO. VAC A Hz ART. NO. PowerSwing TYPE WEEK EN ISO 9001 Certificate No: SITAC /99 Landskrona Sweden Factory No (3 5 /32") LSO HSO LSO HSO HSC LSC HSC PUSH LSC (4 9 / 16 ") Z PULL Z M5 109 (4 9 / 32 ") 582 (22 29 / 32 ") AAF316EMA FAA074F0EMEI Issued

20 Mechanical installation Mounting the drive arm and door fitting 1 Connect the mains power (see page 19). 2 Open the door to an angle of Give constant impulse by strapping the impulse inputs on the control unit. The drive shaft turns to a factory-set position. 4 Slide the guide shoe into the door fitting. 5 Using dimensions shown from hinge centre line, mount the door fitting to the door panel fastening securely (see drawing for PULL-P). 6 Mount the drive arm on the drive shaft with the door in unchanged position (90 ). Ensure that the teeth of the adaptor fit well with the operator drive shaft and the drive arm. 7 Tighten the screw to a torque of 25Nm. 8 Slide the arm stop against the guide shoe and then back 20 mm. The guide shoe must not hit the arm stop during normal operation. Fasten the arm stop. 9 Remove the strapping. The motor turns off and the door closes. 10 Snap on the end plates to the door fitting Checking the door movement Push the door to its fully open position. Check that it can open to the required angle and that the guide shoe runs easily in the track of the door fitting. Check also that the complete arm system operates without problems. 20 Issued FAA074F0EMEI

21 Electrical connection 9.0 Electrical connection 9.1 Control units Note! During any work with the electrical connections the mains power must be disconnected. The operator can be equipped with different control units adapted to the functions required. CSDA This basic control unit is equipped with inputs for connection of automatic and manual activation units (such as radars, photocells, normal push buttons, emergency push buttons), presence detection etc. Electro-mechanical striking-plate, slave control unit CSDA-S for double doors as well as presence sensor with limited functions can also be connected. CSDA-S This slave control unit is used together with CSDA for double doors as explained above. FAA074F0EMEI Issued

22 Electrical connection 9.2 Connection of control unit CSDA single doors Connect the mains power to the mains terminal block. Note! Accessories and activation units must not be connected until the adjustment of speeds etc. has been carried out. Note! It is important that the high and low voltage cables are well separated and fixed. The high voltage cables must be routed and fixed on one side of the drive unit by using the enclosed cable holders and the low voltage cables must be routed on the opposite side using the same type of cable holders. From limit switch opening From opening F2 = 250 mat F1 = 6.3 ATH TB2 AAE274 TB2 Motor control 0 V DC "Slave" control 24 V DC TB8 TB1 Kill 0 V DC Impulse Lock 24 V DC (+)13-20 V DC From motor N L Mains power 1234 TB Capacitor Hold open time, 0-30 s 1234 TB2 (+) Motor control 0 V DC Slave control 24 V DC, max. 200 ma Kill 1) 0 V DC Impulse 24 V DC max. 375 ma Lock V DC max. 275 ma Not to be used 2) Locked with power Locked with power Locked without power Kill 1) Motor control ON Not to be used Not to be used Spare jumper ( ) ( ) (+) (+) 1234 TB TB8 1) Remove jumper Kill on TB8 when connecting to terminals No. TB1:1 and 2 2) Jumpers on TB8:2+5 give lock opening time = hold open time AAF292EMB 22 Issued FAA074F0EMEI

23 Electrical connection 9.3 Connection of control units CSDA and CSDA-S double doors For double door operators both operators have to be connected to the mains. A four-pole cable has to be connected between TB2 on the CSDA and TB6 on the CSDA-S. Motor control 0 V DC Slave control 24 V DC Note! It is important that the high and low voltage cables are well separated and fixed. The high voltage cables must be routed and fixed on side of the drive unit by using the enclosed cable holders and the low voltage cables must be routed on the opposite side using the same type of cable holders. (+) From motor TB CSDA-S R11 TB6 From opening valve From limit switch opening F1 F2 L N Mains power TB 2 TB 6 Cut the resistor R11 if increased opening delay (0,5 sec.) is required for the slave door F2 = 250 mat F1 = 6.3 ATH CSDA TB2 AAE274 TB Motor control 0 V DC "Slave" control 24 V DC TB1 TB TB1 Kill 0 V DC Impulse Lock 24 V DC (+)13-20 V DC From motor N L Mains power 1234 TB2 (+) Motor control 0 V DC Slave 24 V DC AAF290EMA FAA074F0EMEI Issued

24 Start-Up 10.0 Start-Up Give a short opening impulse by strapping the impulse input and adjust if necessary as follows. See also illustration on page Set the hold open time with the potentiometer on the control unit. 2 Adjustment of the opening speed. a Adapt the high speed opening HSO to the existing traffic situation. Turning clockwise decreases the speed. Recommended opening time is 4 sec. b The low speed opening LSO needs to be adjusted only if the door is extremely heavy. Turning clockwise decreases the speed. Recommended opening time is 2 sec. Note! If it is hard to obtain an even and smooth braking, the opening torque (pump pressure) must be reduced. 3 Adjustment of the closing speed. a Adjust the low speed closing LSC as low as the traffic situation allows. Turning clockwise decreases the speed. Recommended closing time is 8 sec. b If a higher closing speed is required, open the high speed closing valve HSC (closed from factory). Note! If the installation requires adjustment of the closing torque follow the instructions on page Fine-adjust the opening angle by means of the limit switch (3). The limit switch is slid into a groove in the hydraulic unit and tightened with a lock screw. By moving the limit switch sideways the opening angle is changed. Note! To make the adjustment easier, the limit switch can be moved to the underside of the hydraulic unit. Any of the grooves at the motor side of the outgoing shaft can be used. 5 If an electromechanical striking plate is installed, an additional lock-kick can be obtained during the last 5 of the closing cycle by adjusting the screw LK on the hydraulic unit. This screw is normally closed. Adjust by opening the screw 90 and check the function. Note! Opening the screw too much may delay the opening. 6 Connect the activation units. 7 Check that the installation complies with valid regulations and requirements from the authorities. 24 Issued FAA074F0EMEI

25 Start-Up Closing torque/force To comply with authority requirements or to overcome over/under pressure the closing torque can be adjusted. The closing torque (spring force) is adjusted by means of an Allen screw (1) placed at the end of the spring tube. Turning the screw clockwise increases the force. One turn equals a torque change of approx. 1 Nm (28 turns from min. to max.). The door must be in open position when extremely low torque is adjusted. Recommended closing force is for PUSH 35 N and for PULL 20 N. Torque Closing Opening Opening torque/force If the closing torque (spring force) has been changed, or if the door does not open to its full extent, the opening torque (pump pressure) must be adjusted as follows: 1 The factory set torque for PUSH is 70 Nm and for PULL 40 Nm at a door opening angle of Measure the opening force by using a spring balance and adjust if necessary. The torque is adjusted by means of an Allen screw placed on the pump (2). Turning clockwise increases the opening torque/pump pressure. One turn equals a torque change of approx. 30 Nm. Recommended opening force is for PUSH 70 N and for PULL 40 N. (1) Screw for adjustment of spring force (2) Screw for adjustment of pump pressure. (3) Limit switch for adjustment of opening angle (4) Limit switch (option), 1 A, 200 V DC HSO = High speed opening LSO = Low speed opening HSC = High speed closing (normally closed) LSC = Low speed closing LK = Screw for adjustment of lock kick (normally closed) Note! The hydraulic unit has grooves both on the upper side and on the underside. The limit switch can be slid into any of the grooves at the motor side of the outgoing shaft. FAA074F0EMEI Issued

26 GND Start-Up 10.1 Connection of activation units and accessories PB / ES Eagle One EYE-TECH Time switch (by others) CSDA/TB (See dwg ) (1 2) 1 1 Door will close, all impulses disconnected PS-3A PS-2 Black Yellow Kill switch 3 Red Kill function active will: make door spring close immediately but will not set hold open time to zero (deactivated kill could reopen) open lock on impulse (will not open lock if impulse is connected to TB1:2 and 4) CSDA/TB1 (4 3 2) Remove jumper Kill on TB8, connect impulse to TB1:2 and 4 AAF284EMB 26 Issued FAA074F0EMEI

27 Cover 11.0 Cover The cover and mounting plate are manufactured in clear anodized aluminium. The end plates are made of a black aluminium Fitting and removing the cover The cover is slid over flanges in the end plates and fixed to the underside of the mounting plate with one screw and one toothed washer for earth connection. AAE274 TB2 Motor control 0 V DC "Slave" control 24 V DC 1234 TB1 0 V DC Impulse Lock 24 V DC (+)13-20 V DC Kill 3 HSO LK LSC HSC LK LSC HSC LSO HSO LSO TB AAF289EMA 1 (1) Earth/Fastening screw (2) Toothed washer for earth connection (3) End plate FAA074F0EMEI Issued

28 Troubleshooting 12.0 Troubleshooting Fault Possible reasons why Remedies/Explanation The door does not open The motor does not start The door does not open The motor starts The door does not open to required angle Programme selector is set to OFF Motor power is missing Mains power is missing Fuse has blown Activation unit does not function Electric striking plate is binding Arm system has come loose Limit switch opening has come loose Change setting Check motor cable Check power Replace fuse Strap impulse inputs Adjust striking plate Readjust pre-tension and tighten arm system Check limit switch The door does not close Constant impulse is created Disconnect activation unit or replace control unit The door does not open fast enough The door opens with too much delay No smooth braking during operation Pump pressure is too low Lock-kick valve is opened too much Pump pressure too high Low speed opening distance too short Adjust pump pressure Adjust valve screw Adjust pump pressure For PUSH: Losen the drive arm from the operator shaft. Increase the pre-tension and fix the arm. For PULL: Give constant impulse. Losen the drive arm from the operator shaft. Move the door 5 deg. towards closed position and fix tthe arm Adjust the limit switch for the opening angle. High sound level Motor in contact with mounting plate Mount two extra screws at the motor side to seduce the mounting plate to the wall The door does not stay open Magnetic valve out of operation Check by pressing the pin on top of the magnetic valve. If the door stops, then check the resistance (should be 150 ohm) for the wire between the magnetic valve and the control unit. 28 Issued FAA074F0EMEI

29 Installation examples 13.0 Installation examples (1) Aluminium profile system (2) Plasterboard wall (3) Reinforced concrete wall and brick wall (4) Plasterboard wall (5) Reinforced concrete wall A. Steel reinforcement or rivnut B. Steel reinforcement C. Expansion-shell bolt (for brick wall min. M6x85, UPAT PSEA B10/25) D. Wodd reinforcement E. Steel beam FAA074F0EMEI Issued

30 EntreMatic AB, Box 669, SE Landskrona, Tel: , Fax: ,

FAA077A2EMEI IIssued 2006-08-15. EntreMatic Swing Door Operator EMSW USER S MANUAL

FAA077A2EMEI IIssued 2006-08-15. EntreMatic Swing Door Operator EMSW USER S MANUAL FAA077A2EMEI IIssued 2006-08-15 EntreMatic Swing Door Operator EMSW USER S MANUAL All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB. Copying, scanning, alterations

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES English AUTOMATION SYSTEMS FOR SLIDING GATES Operating and installation instructions SLIDE SERIES v.0 Rev /202 INDEX ) General Safety Regulations... pág. 0 2) Description... pág. 02 3) Technical Specifications...

More information

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360 INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360 IMPORTANT SAFETY INSTRUCTIONS WARNING! To reduce the risk of injury or death it is important to closely follow all of the following instructions.

More information

K17.12 Door closers K17. Doors 01.09.2013

K17.12 Door closers K17. Doors 01.09.2013 K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - [email protected] - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag.

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag. CONTENTS 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. DESCRIPTION pag.1 3. TECHNICAL SPECIFICATIONS pag.13 4. INSTALLATION pag.13 5. TESTING THE AUTOMATED SYSTEM pag.19 6. MANUAL OPERATION pag.19

More information

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

EC DECLARATION OF CONFORMITY FOR MACHINES

EC DECLARATION OF CONFORMITY FOR MACHINES EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 770 mod. operator is built to be integrated

More information

Model 2300DR Installation Guide

Model 2300DR Installation Guide Model 2300DR Installation Guide POWER ACCESS CORPORATION P.O. BOX 1050 170 MAIN STREET NEW HARTFORD, CT 06057 800-344-0088 WEBSITE: www.power-access.com EMAIL: [email protected] 1 STANDARD PARTS

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

ED 100LE ED 250LE. Low energy swing door operators

ED 100LE ED 250LE. Low energy swing door operators ED LE ED 250LE Low energy swing door operators ED LE & ED 250LE LOW ENERGY SWING DOOR OPERATORS LOW ENERGY SWING DOOR OPERATORS Automatic doors provide a means of opening and closing doors without the

More information

Technical Information

Technical Information Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................

More information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier

More information

LED Security Spotlight User Manual

LED Security Spotlight User Manual MOT ION-TR ACKING LED Security Spotlight User Manual www.jascoproducts.com 1-800-654-8483 2 TABLE OF CONTENTS Parts List 3 Questions? Missing Parts? 4 Installation (Wall mount) 6-9 Installation (Eave mount)

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION P 1 / 5 Model No. Description 8390D Cordless Percussion Driver Drill 13mm CONCEPT AND MAIN APPLICATIONS Model 8390D has been developed by adding percussion mechanism to Model 6390D.

More information

R02GA. July 31, 2002. Dear Blue Bird Owner:

R02GA. July 31, 2002. Dear Blue Bird Owner: R02GA July 31, 2002 Dear Blue Bird Owner: This notice is sent to you in accordance with the requirements of the National Traffic and Motor Vehicle Safety Act. Blue Bird Body Company has determined that

More information

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair SERVICE MANUAL US Corpus 3G Seat system for electric wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 4, 2014-07 Item No.: 205260-US-0

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

430 Power/Electronics Replacement

430 Power/Electronics Replacement Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed

More information

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction GEH6290 g Cable Operator Mechanisms for E150, SE150, SF250, and SG600 Spectra RMS Circuit Breakers Type SCH1/1X, SCH2/2X Flange-Mounted Handle Assemblies, Cable Series SC3L SC10L and Type SC0M1A, SCOM1EF,

More information

Operating Instructions

Operating Instructions Operating Instructions Series L 000 Cord Reels Model Numbers: L 000 L 0 0 L 0 B L 0 X L 00 L A X L 0 L 0 0 L 00 L 0 L 0 B L 0 0 X L 00 L 0 A L 0 X IMPORTANT Read this manual carefully before installing,

More information

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013 Sid/Page 1 SESOBS THE SMOKE DENSITY MONITOR - Easy and safe to operate and install - Complete with sealing air fans. - Remote smoke density indication possible. - Designed to meet with the environmental

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

Original Assembly Guide

Original Assembly Guide TCT Multipurpose Single Bevel Sliding Compound Mitre Saw Original Assembly Guide Read instructions before assembling this tool. Table of Contents GB Assembly Guide Read instructions before assembling this

More information

Awning Instructions. Full Cassette 1.5m to 6m

Awning Instructions. Full Cassette 1.5m to 6m Awning Instructions Full Cassette 1.5m to 6m English Full Cassette Manual & Electric Instructions Contents Warning 1.5m - 3.5m Awnings 8 x Expansion bolts ** 2 x brackets 1 x Awning 1 x Winder 4.0m -

More information

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic

More information

DORMA ED 800 SERIES Service Manual

DORMA ED 800 SERIES Service Manual DORMA ED 800 SERIES Service Manual ED 800J ED 800T software level 3.27M www.dorma-usa.com 1-800-523-8483 INSPK NO. 08280020 Rev.08/07 08280021 08/07 TABLE OF CONTENTS Page Status Light...3 Status Light

More information

TABLE-TYER / TABLE-TYER SS POWER STRAPPING MACHINES 04/12/07

TABLE-TYER / TABLE-TYER SS POWER STRAPPING MACHINES 04/12/07 TABLE-TYER / TABLE-TYER SS POWER STRAPPING MACHINES 04/12/07 CONGRATULATIONS Thank you for purchasing your Table-Tyer Strapping Machine. The Table-Tyer has been designed to be a reliable, maintenance free

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors

Quality Operators for Garage Doors and Entrance Gates. Garage door operator LIFTRONIC for up-and-over doors and sectional doors MORE CONVENIENCE FOR YOUR HOME Quality Operators for Garage Doors and Entrance Gates Garage door operator LIFTRONIC for up-and-over doors and sectional doors Entrance gate operator PORTRONIC for hinged

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory TRIM Application 2008 ACCORD 4-DOOR Publications No. AII 35362 Issue Date AUG 2007 PARTS LIST Steering Wheel Trim (Without Navigation) P/N 08Z13-TA0-100 Right steering

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 Installation instruction do88 Intercooler for Volvo S40 / V50 / C30 This instruction shows how to replace the OEM intercooler with our performance intercooler. 2. 3. 1. 4. 5. Part number: ICM-170 6. At

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

4.3-inch Back-Up Camera

4.3-inch Back-Up Camera TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than

More information

Comfort 250, 252 Operator System for Garages Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen

Comfort 250, 252 Operator System for Garages Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen Comfort 250, 252 Operator System for Garages Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen Anriebssystem für Garagen Installation and Operating Instructions GB Einbau- und

More information

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Operating Instructions

Operating Instructions Operating Instructions Series L 4000 Spring Driven Cord Reels 63 3 3 3 7A 63 0 63 3 3-RP 3 7B 63 X 6 3 3A 63 8 3 X 6 3 3A-RP 63 8 L 4000 63 3 3 3B 63 9 L 400 63 3-RP A 63 5 3 9 L 4500 63 3 A 63 5 3 9G

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Front axle components, overview

Front axle components, overview just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Rear wheel brakes, servicing. Стр. 1 из 45. Note: Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Manual. Simrad StructureScan LSS-1 Sonar Module. English Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors 00, 00, 300, 400, 600, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors Installation, Maintenance & Parts Manual Featuring: Technology DORNER MFG. CORP. INSIDE THE USA OUTSIDE

More information

Parts#MB003-003 Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna)

Parts#MB003-003 Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna) Installation Instructions Reverse Gear MAMBA (Monoblock for Cable operated) Read and become familiar with these installation instructions before start. Two Piece for H-D 5 Speed Trans., Cable operated

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators

Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators NABCO ENTRANCES Inc. S82 W18717 Gemini Drive Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 Technical Assistance: 866-622-8325 www.nabcoentrances.com Email: [email protected] Analog Control

More information

Removable Aluminium posts

Removable Aluminium posts Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: [email protected] Removable Aluminium posts Single Pole

More information

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge... Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge... Pivot

More information

V1504 Vertical Platform Lift OWNER S MANUAL

V1504 Vertical Platform Lift OWNER S MANUAL V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 01-m03-2016 2 IMPORTANT Ensure that only an authorized Savaria Dealer

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 [email protected]. Clamps Clamping devices

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 Email_pzoli@kiralytrading.hu. Clamps Clamping devices 04000 Clamps Clamping devices 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 297 04010 Adjustable straps Tempered steel 1.1191 Black oxide finish nlm 04010-101 Suitable thrust

More information

Operating Instructions Drill rig DRU160

Operating Instructions Drill rig DRU160 Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

Retrofit Kit Manual. Low Energy Operator

Retrofit Kit Manual. Low Energy Operator G Y R O T E C H ENTRANCES Inc. S82 W18717 Gemini Drive P.O. Box 906 Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 www.nabcoentrances.com Automatic Entrance Systems Retrofit Kit Manual Model 710

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents -J0 REV. 00--0 POWER LOCK KIT GENERAL Kit Number -0, 0-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com (English

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

This instruction is valid for all ACD pump models shown on page 2

This instruction is valid for all ACD pump models shown on page 2 Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

Remote Head REMO ONE. Code 5750. Manual

Remote Head REMO ONE. Code 5750. Manual Remote Head REMO ONE Code 5750 Manual by sachtler. All rights reserved Version: 1.2/09/05 Issue date: September 2005 Order no.: srh20t010a We want you to receive Sachtler products that are always state

More information

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Manual for GlobePharma Mini-Press II Rotary Tablet Press 1 of 13 Preparing the Rotary Press 1. Make sure the rotary press is unplugged. 2. Open the bottom cabinet of the rotary press and take out the grey tool kit, and the beige box of punches and dies. 3. Take

More information

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke

More information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

TRANS-05, Torque Tube Removal, Rebuilding, and Installation TRANS-05, Torque Tube Removal, Rebuilding, and Installation Tools Metric Wrench Set Metric Socket Set Jack Stands (6 minimum) Floor Jack 8mm Cheesehead socket (also referred to as 12 point internal socket

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual

More information

Swing Door Opener MODEL: DM-50 / DM-100. www.skylinkhome.com

Swing Door Opener MODEL: DM-50 / DM-100. www.skylinkhome.com www.skylinkhome.com Swing Door Opener MODEL: DM-50 / DM-00 P/N. 0A393-00 DEC, 2005 CUSTOMER SERVICE 7 Sheard Avenue, Brampton, Ontario, Canada L6Y J3 Tel : (905) 456-8883 Fax : (905) 456-789 Email : [email protected]

More information