XA Sodium Leak at Monju (I) - Cause and Consequences -
|
|
|
- Magdalen Griffin
- 10 years ago
- Views:
Transcription
1 Sodium Leak at Monju (I) - Cause and Consequences - XA H. Mikami, A. Shono and H. Hiroi, Reactor and System Engineering Section, Monju Construction Office, Power Reactor and Nuclear Fuel Development Corp. 2-1, Shiraki, Tsuruga-shi, Fukui-ken, Japan Abstract On December 8, 1995, a sodium leak from the Secondary Heat Transport System (SHTS) occurred in a piping room of the reactor auxiliary building at Monju. The sodium leaked through a thermocouple temperature sensor due to the breakage of the well tube of the sensor installed near the outlet of the Intermediate Heat Exchanger (IHX) in SHTS Loop C. There were no adverse effects for operating personnel or the surrounding environment. The reactor core remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. On the basis of the investigations, it was concluded that the breakage of the thermocouple well was caused by high cycle fatigue due to flow induced vibration in the direction of sodium flow. 1. INTRODUCTION Monju is a prototype fast breeder reactor designed to have an output of 280 MWe (714MWt). Monju is fueled with mixed oxides of plutonium and uranium and cooled by liquid sodium. The principal data on plant design and performance are shown in TABLE I. The construction of Monju is a major milestone in the Japanese national FBR development plan, based on the Atomic Energy Commission's long-term program for development of nuclear energy. The Power Reactor and Nuclear Fuel Development Corporation (PNC) is responsible for the management of the project and began construction in October 1985 at the Tsuruga site. Loading of the fuel assemblies into the core started in October 1993 and the reactor attained initial criticality in April The first test generation of electricity was in August After this, the program of power raising tests was being carried out, with the rated power test planned for June 1996; in the course of this program, a sodium leak occurred in SHTS Loop C at 19:47, on December 8, This paper describes details of the sodium leak accident and the present situation of the cause investigation. 271
2 TABLE I Principal Design and Performance Data of MQNJU Reactor type Sodium-cooled / loop-type Number of loops 3 Thermal output 714 MWt Electrical output 280 MWe Fuel material Pu02-UO2 Core dimensions Equivalent diameter 1,790 mm Height 930 mm Plutonium enrichment {inner core / outer core) (Pu fissile %) Initial core 15/20 Equilibrium core 16/21 Fuel inventory Core (U+Pu metal) 5.9 t Blanket (U metal) 17.5 t Maximum burnup(f/a) 80,000 MWD/t Cladding material SUS316 Cladding outer diameter/thickness 6.5 / 0.47 mm Blanket thickness Upper / lower / radial 30/35/30 cm Breeding ratio 1.2 Reactor vessel height /diameter D rimary coolant systems Coolant sodium mass Inlet / outlet reactor temperature Steam temperature (turbine inlet) Steam pressure (turbine inlet) Type of steam generator 18/7 m 760 ton 397 / 529 'C Coolant flow rate 5.1X10 6 kg /h / loopx3loops Coolant flow velocity 6nVs(inlet), 4m/s(outlet) Secondary coolant systems Coolant sodium mass 760 ton Inlet / outlet IHX temperature 325 / 505 "C Coolant flow rate 3.7X10 kg /h / loopx3loops Coolant How velocity 5 m/s Water - steam systems Feed water flow rate 113.7X10 4 kg/h C 12.7 MPa Helical coil Refueling system Single rotating plug with fixed arm FHM Refueling interval 6 months 2. SUMMARY OF THE ACCIDENT AND POST-ACCIDENT RESPONSE Following a programmed shutdown, Monju restarted operation on December 6, On December 8, while power was being raised for a plant trip test as part of the 40% electric power test (thermal power 43%), a high sodium temperature alarm at the outlet of the IHX in SHTS Loop C sounded at 19:47 and at approximately the same time the fire alarms (smoke detector) sounded in the same area. A sodium leak detection alarm followed, indicating that there was a sodium leak in the piping room of SHTS Loop C. The plant conditions at the time of the sodium leak occurrence are shown in Fig.l. PHTS:Primary Heat Transport System SHTS:Secondary Hen Transport System Outar shielding wall Feed v ater temp. 193"C ilowra a:40% Fig.1 Monju Plant Condition (just before the Sodium Leak) 272
3 The presence of smoke was confirmed when the door of the SHTS Loop C piping room was opened. The plant operators determined that a sodium leak had occurred and decided to begin a normal plant shut-down operation, the correct Operating Procedure for what they judged to be a small-sized sodium leak. Reactor power-down operations began at 20:00. The state inside the piping room was checked again at 20:50 by partially opening its door and an increase in white fume was observed. Accordingly, electric power generation was stopped at 21:15, and the reactor was manually tripped at 21:20. Immediately after the trip, the reactor was cooled by the Auxiliary Cooling System (ACS) of all three secondary loops. In order to stop the leak, the draining of sodium from the affected loop was started at around 22:40. The blowers of the air ventilation system for Loop C were turned off automatically at 23:13 by the low sodium level interlock on the evaporator. The loop draining operations were completed at 00:15, December 9. Later, the sodium in the Primary Heat Transport System (PHTS) Loop C was also drained. Subsequent decay heat removal from the core was therefore by the PHTS, SHTS and ACS of Loop A and Loop B operated at minimum flow rate. As it was a secondary cooling system leak, there was no radiation effect from the leak for either the general public or the plant personnel. An inspection of the SHTS Loop C piping room on December 9 confirmed the presence of solidified sodium residue materials in the vicinity of the thermocouple well at the secondary-side outlet of the IHX. It was concluded that the thermocouple well was the probable origin of the leak. The state of the piping room after the sodium leak is shown in Fig.2. On the 6mm thick steel floor liner approximately Im3 of sodium compounds formed a semicircular mound, nearly 3m in diameter and 30cm high. Other sodium compounds resulting from the leak were lightly spread over the floor and walls of the room. The only damage observed was to a ventilattion duct and an access walkway. The ventilation duct, running directly under the SHTS piping, had a hole extending over half the perimeter facing the wall with lumps of deposits around the opening. On the steel walkway grating under the piping, an opening was formed and globules of deposits stuck around the edges. Sodium compounds from the leak were found over the entire floor of the Steam Generator room of SHTS Loop C connecting to the piping room and in the passages. From December 14, work began to remove and recover sodium compounds from the floor near the leak site. About 3m length of the ventilation duct which obstructed access to the suspect temperature sensor was removed during January 4-8, in order to make a closer inspection and establish the cause of the leak. 273
4 See illustration below fora detailed look at this section flf SHTS»C loop piping room i As seen from the direction of the arrow above Temperature Containment Vessel / penetration I I I A lump of deposits on the han Half the perimeter of the ventilation duct facing the wall is lost to a width of about 25cm and lumps ol deposits round the opening Grating A semi-spherical lump of deposits at the temperature sensor and the external insulation cover plate directly underneath lost s. Outer shielding wall (Concrete) A semi-circular pile of deposits (3m in diameter, 30cm high) formed on the steel floor liner The color of the concrete wall turned blackish An hole formed in the grating with globules of deposits adhering the edges Fig.2 The State of the Piping Room (C) after the Sodium Leak 3. INVESTIGATION OF THE CAUSE 3.1. Organization of the investigation After the accident investigations were started by PNC and independent nuclear safety organizations. The Nuclear Safety Bureau (NSB) of the Science and Technology Agency (STA) set up a task force to investigate the cause of the accident and consider effective measures for preventing another sodium leak in Monju. Another independent investigation was launched by the Nuclear Safety Commission (NSC) whose working group was assigned to work under the direction of the Research & Development Reactor Subcommittee of the Reactor Safety Review Committee. The scope of this investigation covered not only technical matters but all aspects of software, such as operation manuals and information management systems. 274
5 PNC's investigations have been carried out under the supervision of STA's "Investigation Task Force on the Sodium Leak Accident in Monju"; the task force members consisted of STA's Nuclear Safety Technology Panel experts. The schedule of the technical investigation is shown in Fig.3. Fig.3 Progress The Schedule of the Cause Investigation Dec.95 I Jan.96 Feb,96 Mar.96 Apr.96 May.96 Jun.96 Jul.96 Aug.96 Sep.96 Conlimalion thai the well lube lip wadost. Discovery ot ihelos part leted part )f Recovery ol I he lod part eaks burning Investigation ol the affected temperature sensor Investigation ol other temp, sensors in secondary loops Securing safety of inlact loops niegnty conlimalion ol C loop sensors Cul out / inspscllon ot Intacl sensor Recovery of the lost well tube tip Survey of effects on facilities Survey ol effects on equipmentqeanup Estimation of total quantity of leaked sodium Experiments and analyses for cause investigation ( inspection and dean up equlpmenl, control panels and areas contamin; k. by sodium composlle /Recovery and analysis ot sodium composite f inierlm estlmalion/evaluation Final c Analysis ol How induced vibralion and hydraulic tests Experiments Estimation Analyses / Evaluation 3.2. The affected temperature sensor The thermocouple wires are enclosed in a sheath that is itself housed within the well tube. This well tube extends horizontally toward the center of the pipe. The tip of the well tube (some 15 cm in length) is thinner in diameter than at its root. (Fig. 4) Inner cover of thermal Insulator Secondary main pipe (558.8 mm* mm Thermal\ * \insulator\\\* outer cover of thermal Insulator Well Tube 10 mm* 1-3 mra 1 54M mm Thermocouple ;.'. :; ' ' Insulation filler \.'.-. ', Flow direction Guide tube lor thermocouple Fig.4 The Thermocouple Well of the Secondary Loop On January 7 & 8, radiographs were taken of areas close to the temperature sensor to investigate the cause of the sodium leak, specifically to estimate the extent of remaining sodium compounds 275
6 around the temperature sensor and to assess its structural condition. It was found that the tip of the well tube had been lost and the thermocouple (3 mm diameter) was bent at an angle of 45 degrees toward the downstream flow direction (Fig.5). The protective body of the thermocouple unit was found to be filled with sodium compounds; but the thermal insulating materials around the thermocouple did not exibit density shadows typical of the compounds. No other anomalies were observed on the radiographs. These findings confirmed that the failure of the thermocouple well was the direct cause of the sodium leak. Gap for monitoring the Sodium Leakage Bent at an angle of approximately 45 Mhenmaunsutator : Well Tube / (LOSt) >;; Sodium Flow Direction! Thermocouple: : : Secondary Loop Pipe A/Vati: : Fig.5 The Sodium Leak Flow Path From February 7-9 the entire temperature sensor, thermocouple and well, together with a small section of the adjacent pipe wall, was cut out for the detailed investigation and transported to the Japan Atomic Energy Research Institute (JAERI) The other temperature sensors in the SHTS Visual, ultrasonic and radiographic examinations were used to confirm the integrity of all the other temperature sensors in the SHTS. As an interim solution to prevent any further leaks, the temperature sensors of the same design in the intact secondary loops, Loops A & B, were reinforced with additional seals. Three intact temperature sensors were cut out for Loop C for the detailed investigation Location and recovery of the lost well tube tip The search for the lost well tube tip of the thermocouple well began on January 26. Firstly, radiography was carried out along the horizontal pipes downstream of the affected temperature sensor on the secondary main cooling system (hot leg) and the secondary sodium filling-draining system, a total of about 185 m in length.but the well tube tip was not found. On March 28, a CCD camera inserted into the sodium-inlet header of the superheater, showed the lost well tube to be in the distributor at the top of the superheater (Fig.6). The lost well tube tip was recovered using a specially developed gripper on April
7 Side Wall (Holes with Diameter 5mm) Lost Well Tube Tip Structure of the Distributor 'installed inside the Superheater Bottom (Holes with Diameter 3mm) Fig.6 The Lost Well Tube Tip found by CCD Camera in the Distributor _... inside the Superheater 3.5. The cause of the well tube breakage Detailed microscopic and metallographical examinations of the well tube and the fractured surface, examination of welded parts of the well, and the thermocouple sheath were carried out at JAERI (from February 13) and the National Research Institute of Metals (NRIM) (from February 16). The results of the microscopic inspection of the fractured surface of the thermocouple well are shown in Fig.7. secondary crack main crack : crack initiation and coalescence region : metallography and crystalline dependent fracture surface : striation region : dimple region : protrusion observed -: crack propagating direction secondary crack : crack front (presumption) Fig.7 Microscopic Inspection of the Fracture Surface of the Thermocouple Well Row induced vibration analysis and mock-up tests have been conducted to identify the direct cause of the failure. On the basis of these investigations, it was concluded that the breakage of the thermocouple well was caused by high cycle fatigue due to flow induced vibration in the direction of sodium flow. The results of the analysis of flow induced vibration are shown in Fig.8, where the stream line oscillations of the well tube were observed with symmetric vortex shedding from both sides of the tube. According to fatigue crack analysis, on the basis of the operational history, it was deduced that the cracks initiated at an early stage of the 100% flow operation, propagated in the subsequent operation, and finally led to the failure of the well tube in the last period of 40% flow operation. This failure mode agreed with the results of the examination of the rupture surface and a full scale in-water hydraulic vibration experiment. 277
8 > ; issi ml ft t = to us 2 t = to 3 t = to + 96Ons 4 t = to+144ons 5 t = to+192ons 6 t = to+24oons Analysis Condition Sodium Flow Rate: 100 % (5 m/sec) Sodium Temperature: 200 'C Damping Ratio: 0.5 % Fig.8 Analysis of Flow-Induced Vibration 7 t = to+288ous 8 t = to The problems were in the design of thermocouple well tube. The designers applied the ASME (American Society of Mechanical Engineers) Performance Test Code, PTC 19.3, where the design rules are provided only for the recommendedtapered well tube to prevent resonant vibrations of the well tube due to vortex shedding. These were inappropriate for the Monju well tube having a local sharp taper (at an angle of 120 degrees). As a result, the vortex induced vibration in the drag direction could not be prevented. Another point was that PNC and fabricators involved did not take account of the issue of the 1991 addenda to the ASME Boiler and Pressure Vessel Code, Section III, Appendix N, the newly published non-mandatory design rules, which includes the prevention of vortex-induced vibrations in both lift and drag direction. An opportunity to make a re-evaluation of the design of thermocouple well tube in the light of this code revision was Operational procedure problems There were deficiencies in the Operating Manual for the handling of abnormal events and the actions of the operators were not deemed appropriate. Specifically, the problems are as follows ; (1) The size of the leak should have been recognized early on, and the reactor shut down immediately by a manual trip. (2) Monitoring of the plant and visual inspections of the leak site were not carried out appropriately. (3) After the second inspection, an emergency shut down was decided but the action was delayed. (4) A procedure for the draining of sodium at high temperature (i.e. that does not require a cooling period) should have been prepared. 278
9 (5) The ventilation system should have been stopped at an early stage. (6) All of the operators should have been made proficient in sodium technology with sufficient training. 4. MEASURES AND SOLUTIONS (Fig.9) On February 9, 1996, the NSB of the STA issued a report', which pointed out 14 items problem areas and called for the implementation of safety review on nuclear facilities. PNC carefully reviewed the report and urgently submitted its reply on February 27. On May 23, 1996, the STA issued a consective report on the accident Plant Improvement All similarly designed temperature sensors in the SHTS will be replaced. Considering the extensive effects of the sodium fire, all aspects of the emergency operation and leak related equipment will be re-assessed and any required improvements carried out. Specifically, the reactor will be shut down immediately if a sodium leak is confirmed. Improvements will be made to enable quick draining of sodium from the SHTS in the event of a leak. The Operating Manual will also be revised to clarify definitions of leak size, and operator responsibilites and actions. Equipment such as the sodium leak detection system, the fire detection system, the ventilation system, will be reviewed and, if neccessary, improved. New remote monitoring systems such as closed circuit television cameras will also be installed in SHTS areas. (1) Prevention of Sodium Leak Replacement of the same type temp, sensors To secure safety ol othertype sensorsandotherstructures (5) Review of Operation Management Newlydesignatedsupervisorfor sodiurrtechnology Establishmenbfeubstantial educationandtrainingsystem ^Strengtheni ngpemergency -response organization '2) Grasp Situation of Leakage >nitoring System for Sodium Leak- Installationofnewmonitoring systenrxivt.etc.) Improvementoffiredetection & sodium leak detection systems f 3) Suppression of Leakage - Early drainage of sodium - Eariyshutdown of reactor Eartydrainageof sodium tonju Improvement Program (6) Safety Review ' Inspectionofequipment ancfacilities Studyon foreign experienceand reflection (7) Confirmation of Safety of FBR system '(4) Mitigation of Effects by Leaked Sodium -Early Suspension Ventilating System Operation - Improvementolventilatingsystem andearlysuspensionofoperation Improvement of sodium technology Establishmentof Technology DevelopmentCenter Trainingofoperationand maintenance Fig.9 The Monju Improvement Program 279
10 4.2. External response at the time of the accident Considering the delay in initially reporting the accident occurrence, operational procedures have been revised. Under the new procedure, the responsible person at the site should immediately make an initial report. Thorough practical training will be undertaken, short and effective information routes established, to supply accurate information at the right time Review of Emergency Response Organization A review of the Emergency Response Organization was carried out. The number of facilities reviewed was 46, including Monju, Fugen, and Joyo. Regulations were revised to speed up the reporting and supply of information Establishment of "technical trust" and "social trust" The accident poses two sorts of problems: the technical problems associated with a sodium leak and the public confidence issues resulting from PNC concealment of some of the videotape records in the immediate aftermath of the accident. These are two very different problems which must be considered separately. Nevertheless, the concealment of information has detracted from the credibility that had been built up and has been used to ferment misgivings about the development of FBRs. From the experience of this accident, it is clear that regaining the establishment of "technical trust" and "social trust" are of paramount importance. To tackle the problem of technical trust, specifically in PNC's safe application of sodium technology, the following actions will be taken ; (1) Establishment and practice of countermeasures (2) Examination of other facilities (3) Review of regulations and Emergency Operating Manuals (4) Review of emergency response organization of each nuclear facility (5) Newly designated supervisor for sodium technology (6) Inspection of equipment and facilities (7) Study of foreign experience PNC will also carry out complete safety review of Monju. Crisis management information release to the public, and strengthening of communication with local communities will all be addressed. Specifically, PNC actions to regain social trust are as follows ; (1) Reinforcement of crisis management organization Rearrangement and reinforcement of emergency response organization Improved training system for operation shifts teams, etc. (2) Sufficient information release to the public Establishment of "Public Information Section" in PNC head office, etc. (3) Strengthening of communication with local communities Start of local round-table meetings Investigation of the opinions of general people, etc. 280
11 On April 1, PNC set up a Public Information section in PNC's Headquarters. This will further promote the understanding and distribution of information on PNC as a whole and make plans to deal with information distribution. For each plant, a supervisor of information distribution was designated whose aim is to promote the thoroughness, correctness, and promptness of information distribution at each plant. 5. CONCLUSION With regard to the sodium leak and consequential sodium fire, it was recognized that breakage of relatively small parts attached to sodium pipes, such as the thermocouple well tube, may cause large effects on social acceptance of FBR. The sodium leak accident revealed that there were problems with the precautions for secondary heat transport liquid sodium systems and that more importance has to be attached to be supply of accurate information. In addition to the investigation and analysis of technical causes for the accident, exhaustive study will be given to the way information should be supplied and responses offered in the event of an accident. It is very much to be hoped that the lessons of this accident will be put to effective use in the progress toward commercial utilization of plutonium under appropriate safeguards. 6. REFERENCES 1. STA / NSB, "Report on the Investigation into the Sodium Leakage Accident at the Prototype FBR Monju of the PNC", February 9, STA, "Report on the Sodium Leakage Accident at the Prototype FBR Monju of the PNC (Interim Investigation Report)", May 23, NEXT PAGE(S) left BLANK
Retrieval of Damaged Components form Experimental Fast Reactor Joyo Reactor Vessel
Retrieval of Damaged Components form Experimental Fast Reactor Joyo Reactor Vessel June. 8 th, 2010 Yukimoto MAEDA Japan Atomic Energy Agency (JAEA) Experimental fast reactor Joyo Joyo (Oarai R&D Center)
The integrity evaluation of the reactor building at unit4 in the Fukushima Daiichi nuclear power station
The integrity evaluation of the reactor building at unit4 in the Fukushima Daiichi nuclear power station May 2012 Government and TEPCO s Mid-to Long Term Countermeasure Meeting Management Council Outline
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS
A DB RILEY TECHNICAL PUBLICATION CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS by James P. King, Design Manager DB Riley, Inc. Presented at the 1998 ASME
Boiling Water Reactor Systems
Boiling Water (BWR) s This chapter will discuss the purposes of some of the major systems and components associated with a boiling water reactor (BWR) in the generation of electrical power. USNRC Technical
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
Generation IV Fast Reactors. Dr Richard Stainsby AMEC [email protected]
Generation IV Fast Reactors Dr Richard Stainsby AMEC [email protected] Contents The Generation IV international research programme on advanced reactors The case for fast reactors The technology:
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 24 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia S TABLE OF CONTENT SCOPE 2 DEFINITIONS
Preventing Overheated Boiler Incidents
Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.
Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study
Implementation of Emergency Repair Work for Steam Turbine at Himeji No. 2 Power Station, Kansai Electric Power Co., Inc.
June 10, 2015 The Kansai Electric Power Co., Inc. Implementation of Emergency Repair Work for Steam Turbine at Himeji No. 2 Power Station, Kansai Electric Power Co., Inc. The Kansai Electric Power Co.,
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
The Problem Solving of Exhaust Frame Air Cooling System Pressure Low in GE Frame 9 Gas Turbine
The Problem Solving of Exhaust Frame Air Cooling System Pressure Low in GE Frame 9 Gas Turbine Author: Nattapon Pinitchan, Kanyarat Tankong, EGAT (Bangpakong Power Plant), Thailand 1 of 10 ABSTRACT EGAT's
Spray Booth Guideline
Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that
Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections
Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections 296 Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections Fuminobu Takahashi, D. Eng. Shigeru
DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION
DEPARTMENT OF TRADE MERCHANT SHIPPING NOTICE NO.M.847 DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION Notice to Shipowners, Masters, Shipbuilders and Repairers 1. It has come to the notice
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0
UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0 Prepared By: Patrick L. Paquin, EnergySolutions Date Reviewed By: Mirza I. Baig, EnergySolutions Date Approved By: Thomas F. Dougherty, Columbiana Hi
10 Nuclear Power Reactors Figure 10.1
10 Nuclear Power Reactors Figure 10.1 89 10.1 What is a Nuclear Power Station? The purpose of a power station is to generate electricity safely reliably and economically. Figure 10.1 is the schematic of
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:
Autoclave Safety Purpose: Sterilization refers to the complete killing of all living organisms, including spores. Common sterilization techniques include the application of wet heat, dry heat, chemicals,
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Boiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
Inspections Standard Operating Procedure 5 Aboveground Storage Tanks
Aboveground Storage Tanks Aboveground Storage Tank Inspection This Standard Operating Procedure describes the steps that campus units that manage aboveground oil storage tanks (ASTs) or containers must
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 By Carsten Palle, VID Fire-Fill, www.vid.eu Presented at ISTSS
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS W. M. Torres, P. E. Umbehaun, D. A. Andrade and J. A. B. Souza Centro de Engenharia Nuclear Instituto de Pesquisas Energéticas e Nucleares
BWR Description Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering
BWR Description Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering 22.06: Engineering of Nuclear Systems 1 Boiling Water Reactor (BWR) Public domain image by US NRC. 2 The BWR is
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3
GUIDE 26 June 2000 YVL 2.1 Nuclear power plant systems, structures and components and their safety classification 1 General 3 2 Safety classes 3 3 Classification criteria 3 4 Assigning systems to safety
V K Raina. Reactor Group, BARC
Critical facility for AHWR and PHWRs V K Raina Reactor Group, BARC India has large reserves of Thorium Critical facility Utilisation of Thorium for power production is a thrust area of the Indian Nuclear
PERFORMANCE GUIDELINES
1. Foundation/Basement 17 PERFORMANCE GUIDELINES 1. FOUNDATION/BASEMENT 1.1 Efflorescence on concrete or masonry surfaces Efflorescence is the formation of a white crystalline or powdery deposit on the
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Decommissioning situation of Nuclear Power Plant in Japan
Decommissioning situation of Nuclear Power Plant in Japan April, 2015 The Japan Atomic Power Co. The Kansai Electric Power Co., Inc. General Description 1 Operational years of commercial NPP in Japan 40
Olkiluoto 3 Project. AREVA Suppliers Day Warsaw October 4, 2011
Olkiluoto 3 Project AREVA Suppliers Day Warsaw October 4, 2011 Virginie MOUCQUOT-LAIHO AREVA OL3 Project Management Office & Communications Manager AREVA Reactor & Services - New Builds EPR Project Fleet
Radioactive waste managment in Estonia past, present and future
Radioactive waste managment in Estonia past, present and future Ivo Tatrik [email protected] Content 1. Status of ALARA 2. Decomission of Paldiski Former Navy Submarine Training Centre 3. Decomission
This will also provide you with the knowledge to insure long life for your Investment
CONDUIT PIPE DRYING This Presentation will guide you to why systems fail! This will also provide you with the knowledge to insure long life for your Investment Drainable and Dryable System Design Trough
Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software
th International Conference on Structural Mechanics in Reactor Technology (SMiRT ) Espoo, Finland, August 9-4, 9 SMiRT -Division 3, Paper 56 Investigations of a Long-Distance MW Heat Transport System with
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
TITANIUM FABRICATION CORP.
TITANIUM FABRICATION CORP. Titanium, Zirconium, and Tantalum Clad Construction General Considerations In many applications, particularly for large pressure vessels designed for high temperature and pressure,
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
HS-901(A) BASIC STEAM HEATING SYSTEMS
HS-901(A) BASIC HEATING SYSTEMS One-Pipe Two-Pipe Basic Steam Heating Systems One-pipe steam heating system EQUALIZER SAFETY FACTOR STATIC HEAD PRESSURE DROP 2" HEATING UNIT 15" DRIP CONNECTION In a one-pipe,
Overview of the Multi-nuclide Removal Equipment (ALPS) at Fukushima Daiichi Nuclear Power Station. March 29, 2013 Tokyo Electric Power Company
Overview of the Multi-nuclide Removal Equipment (ALPS) at Fukushima Daiichi Nuclear Power Station March 29, 2013 Tokyo Electric Power Company Purpose of Installing the Multi-nuclide Removal Equipment Installation
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
A Code Review for Emergency Generators and Indoor Use of Portable Generators
A Code Review for Emergency Generators and Indoor Use of Portable Generators By: the Fire and Life-Safety Group (FLS) Fire Code requires that emergency generators be stationary generators. Therefore, a
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
E-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.
«1A: Description and Operation» Overview The Evaporative Emission (EVAP) system prevents fuel vapor build-up in the sealed fuel tank. Fuel vapors trapped in the sealed tank are vented through the vapor
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
WWER Type Fuel Manufacture in China
WWER Type Fuel Manufacture in China Yang Xiaodong P.O. Box 273, CJNF, YiBin City, Sichuan, China, [Fax: (+86)8318279161] Abstract: At CJNF, a plan was established for implementation of technical introduction
COOLING SYSTEM Section Page
5 COOLING SYSTEM Section Page 5.1 COOLANT PRE-HEATER... 5-3 5.2 COOLANT PUMP NON-EGR ENGINE... 5-7 5.3 COOLANT PUMP EGR ENGINE... 5-13 5.4 FRONT CONNECTOR HOUSING NON-EGR ENGINE... 5-17 5.5 FRONT CONNECTOR
Electrical Classification
Electrical Classification Using NFPA 70 and NFPA 499 to Classify Hazardous Locations Electrical classifications are established in accordance with the National Electrical Code, NFPA 70, also referred to
Japan s current Nuclear Energy Policy
Japan s current Nuclear Energy Policy Hirobumi Kayama Agency for Natural Resources and Energy, METI December, 2014 Evaluation and Policy Timeframe of Nuclear Power
Transformer Deluge Systems
Transformer Deluge Systems How Do Transformer Fires Ignite? Common causes of transformer failure: Weather-related events such as lightning Short circuits in electrical equipment The most common cause is
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
Terms and Definitions In Canada
Terms and Definitions In Canada Most of the following terms and definitions are taken directly from the National Building Code and referenced Test Methods. Learning these terms will provide an important
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Platform Technology for Computational Fluid Dynamics Supporting Design of System Products
Hitachi Review Vol. 61 (2012), No. 6 244 Platform Technology for Computational Fluid Dynamics Supporting Design of System Products from Power Plants and Industrial Machinery to Home Appliances Shigehisa
COMPUTERISED CORROSION MONITORING STEPS TOWARDS PREVENTING UNEXPECTED CORROSION FAILURES.
R. W. Gregory" COMPUTERISED CORROSION MONITORING STEPS TOWARDS PREVENTING UNEXPECTED CORROSION FAILURES. Traditionally the consequences of corrosion on process plants have been assessed on the basis of
Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.
Exelon Generation 200 Exelo11 Way Kennett Square. PA 19348 www.pxeloncoroi.c cm 10 CFR 50.55a August 13, 2015 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Peach
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Services Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
Government Degree on the Safety of Nuclear Power Plants 717/2013
Translation from Finnish. Legally binding only in Finnish and Swedish. Ministry of Employment and the Economy, Finland Government Degree on the Safety of Nuclear Power Plants 717/2013 Chapter 1 Scope and
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases
VENTILATION Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases If a fire is contained in a building, the heat, smoke, and toxic gases will spread.
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Itemized RAI Responses
Itemized RAI Responses Question 1-1: Justify the use of a tapped bar or equivalent with a helicoil insert. This justification should specifically address any reduction in packaging performance from the
SPILLS & SPILL KITS. Spills -General Guidelines:
Spills -General Guidelines: If handled properly, a spill may be nothing more than a nuisance. If handled improperly, a spill can seriously disrupt your activities and the work of your colleagues. At worst,
Safety issues of hydrogen in vehicles Frano Barbir Energy Partners 1501 Northpoint Pkwy, #102 West Palm Beach, FL 33407, U.S.A.
Safety issues of hydrogen in vehicles Frano Barbir Energy Partners 1501 Northpoint Pkwy, #102 West Palm Beach, FL 33407, U.S.A. Properties of hydrogen Hydrogen is an odorless, colorless gas. With molecular
TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion
B. J. Sanders Consultant 307 Meyer Street Alvin, Texas 77511 TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT After a decision has been made to use zirconium as the material of construction for a shell
Civil Engineering Sector Labour-Management Health and Safety Committee
PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test