System Board D2239 for TX150 S4
|
|
|
- Alvin Kelley
- 9 years ago
- Views:
Transcription
1 PRIMERGY System Board D2239 for TX150 S4 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München München Tel.: (089) Fax: (++49) 700 / D2239 (TX150 S4) Sprachen: En Edition February 2006
2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
3 Contents 1 Introduction Important notes Notes on safety CE Certificate Environmental Protection Features Overview Main memory PCI bus Screen resolution Temperature / system monitoring Interfaces and connectors Settings with jumpers External connectors Replacing the lithium battery Abbreviations D2239 (TX150 S4) Technical Manual
4
5 1 Introduction This technical manual describes the system board D2239, which can be equipped with one Intel processor. You will find further information in the manual BIOS Setup. Further information about drivers is provided in the readme files on the hard disk, on the supplied ServerSupport or ServerStart CDs. Notational conventions The meanings of the symbols and fonts used in this manual are as follows: italics indicates commands, menu items, file and path names or software programs fixed font indicate system output on the monitor semi-bold fixed font indicates values to be entered through the keyboard [Key symbol] indicates keys according to their representation on the keyboard quotation marks Ê V CAUTION! I If capital letters are to be entered explicitly, then the Shift key is shown, e.g. [SHIFT] - [A] for A. If two keys need to be pressed at the same time, then this is shown by placing a hyphen between the two key symbols. indicates names and terms that are being emphasized. indicates an operation that to be performed indicates warnings, which, if ignored, will endanger your health, destroy the system or lead to the loss of data. indicates additional information, notes and tips Table 1: Notational conventions D2239 (TX150 S4) Technical Manual 5
6
7 2 Important notes In this chapter you will find essential information regarding safety when working with the system board. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement. When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server. 2.1 Notes on safety V CAUTION! The actions described in these instructions should only be performed by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts. Only install expansions that are allowed for the system board. If you install other expansions, you may damage the requirements and rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D2239 (TX150 S4) Technical Manual 7
8 Notes on safety Important notes V Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns! Transmission lines to peripheral devices must be adequately shielded. To the LAN wiring the requirements apply in accordance with the standards EN and EN /2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC are to be considered. Never connect or disconnect data transmission lines during a storm (lightning hazard). Batteries V CAUTION! Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter Replacing the lithium battery. 8 Technical Manual D2239 (TX150 S4)
9 Important notes Notes on safety Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. The equipment and tools you use must be free of static charges. Remove the power plug from the power socket before inserting or removing boards containing ESDs. Always hold boards with ESDs by their edges. Never touch pins or conductors on boards fitted with ESDs. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install/deinstall the board. Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (EN , ANSI/ESD S20.20). D2239 (TX150 S4) Technical Manual 9
10 CE Certificate Important notes Notes about boards During installation/deinstallation of the system board, observe the specific instructions described in the service supplement for the respective device. Remove the plug from the mains outlet so that system and system board are totally disconnected from the mains voltage. To prevent damage to the system board, the components and conductors on it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the system board, or any other components, for example EMI spring contacts Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screwdrivers) for leverage. 2.2 CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC Electromagnetic compatibility. Compliance was tested in a typical PRIMERGY configuration. 10 Technical Manual D2239 (TX150 S4)
11 Important notes Environmental Protection 2.3 Environmental Protection Environmentally friendly product design and development This product has been designed in accordance with standards for environmentally friendly product design and development. This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled. This saves resources and thus reduces the harm done to the environment. Notes on saving energy Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work. Notes on packaging Please do not throw away the packaging. We recommend that you do not throw away the original packaging in case you need it later for transporting. Notes on dealing with consumables Please dispose batteries in accordance with local government regulations. Do not throw batteries and accumulators into the household waste. They must be disposed of in accordance with local regulations concerning special waste. All batteries containing pollutants are marked with a symbol (a crossed-out rubbish bin on wheels). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. D2239 (TX150 S4) Technical Manual 11
12 Environmental Protection Important notes Returning, recycling and disposal The device may not be disposed of with household rubbish. This appliance is labelled in accordance with European Directive 2002/96/EC concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU. To return your used device, please use the return and collection systems available to you. You will find further information on this at For details on returning and reuse of devices and consumables within Europe, refer to the Returning used devices manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers Recycling Center D Paderborn Tel Fax Technical Manual D2239 (TX150 S4)
13 3 Features 3.1 Overview The system board D2239 is available in two versions: SCSI version; you will find on the system board a SCSI controller and one SCSI connector SATA version; four SATA connectors and one SATA LED connector Processors 1 x Intel Pentium 4 or Pentium D processor 1 processor socket LGA775 for Intel Pentium 4 or Pentium D processor with 533/800 MT/s (133/200 MHz) front side bus Main Memory 4 slots for main memory DDR2 533/667 MHz (unbuffered), SDRAM memory modules with 512 MB up to 8 Gbyte maximum 8 Gbyte of memory minimum 512 MB ECC multiple bit error detection and single bit error correction Chips on the system board Intel ie7230 chipset ATI VGA controller (RAGE XL) Intel i82801 ICH7R chipset Intel PXH-V PCI-X bridge Super-I/O controller (SMSC DME1737) 1 x GBit LAN controller (Broadcom BCM5721) SCSI controller (LSI 53C1020A) with IME functionality (only SCSI version) Flash EPROM for: BIOS BMC BMC controller ADM1026 thermal and system management controller D2239 (TX150 S4) Technical Manual 13
14 Overview Features internal connectors floppy disk 1 IDE primary power (12V, -12V, 5V, 3.3V and 5V auxiliary) 12V (CPU) power SCSI (only SCSI version) 4 SATA (only SATA version) SATA LED (only SATA version) 1 CPU fan 2 system fans PC98 intrusion detection RSB power IPMB HDD LED front panel battery holder dual USB 2.0 (USB3/4) buzzer SMB1 external connectors 2 serial ports (COM1, COM2) 1 parallel port 2 PS/2 interfaces for keyboard and mouse 2 USB 2.0 ports with 480 Mbits/s (rear) 1 USB 2.0 port with 480 Mbits/s (front panel) 1 VGA port 1 RJ45 LAN port PCI slots 2 x PCI-X (64 Bit / 66 MHz), slot 2 prepared for ZCR (ZCR only possible in SCSI version) 3 x PCI (32 Bit / 33 MHz) 1 x PCI Express x1 (short, 0.5 GB/s) 1 x PCI Express x4 (2 GB/s) 14 Technical Manual D2239 (TX150 S4)
15 Features Overview BIOS features Phoenix System BIOS V 4.06 SMBIOS 2.31 (DMI) MultiProcessor specification 1.1 Server Hardware Design Guide 3.0 WfM 2.0 ACPI 1.0 support LSI-IME SCSI BIOS USB keyboard/mouse boot possible from: 120 MB floppy disk drive CD-ROM USB drives LAN console redirection support OEM logo (optional) Memory disable no Alert on LAN Environmental protection Battery in holder Form factor, slot compatibility list ATX-L ACPI 1.0b, OnNow, PCI 2.3, PCI-X1.0b, PCI-X2.0, PCI Express 1.0a, WfM 2.0, SHDG 3.0, MPS 1.4, IPMI 1.5, PCI SHPC 1.0, USB2.0 D2239 (TX150 S4) Technical Manual 15
16 Main memory Features 3.2 Main memory The system board supports up to 8 Gbyte main memory. 4 slots (2 memory banks with 2 modules) are available for the main memory. Each memory bank can be populated with 512 Mbyte, 1 Gbyte or 2 Gbyte unbuffered DDR2 memory modules. Module population DIMM 1A DIMM 2A DIMM 1B DIMM 2B Figure 2: Main memory If the memory modules are populated in pairs, each pair must consist of identical memory modules (2-way interleaved mode). The module capacity between pairs can differ: pair 2A/2B can be populated with two 512 Mbyte memory modules and pair 1A/1B with two 1 Gbyte memory modules. Following table shows the mandatory population order: single channel dual channel DIMM_1A DIMM_2A DIMM_1B DIMM_2B populated empty empty empty empty populated empty empty empty empty populated empty empty empty empty populated populated empty populated empty empty populated empty populated populated populated populated populated 16 Technical Manual D2239 (TX150 S4)
17 Features PCI bus 3.3 PCI bus Figure 3: PCI slots PCI slots The following table shows an overview of the PCI slots: PCI slot 64Bit/ 32Bit Frequency (MHz) Description 1 32 Bit bit PCI bus slot 2 64 Bit bit PCI-X bus slot, prepared for ZCR 3 64 Bit bit PCI-X bus slot 4 32 Bit bit PCI bus slot 5 32 Bit bit PCI bus slot 6 PCIe x4 bus slot 7 PCIe x1 bus slot Zero Channel RAID (only SCSI version) PCI slot 2 is prepared for Zero Channel RAID (ZCR). ZCR means that the oboard SCSI controller can be upgraded to a SCSI RAID controller through the inserted ZCR PCI card. D2239 (TX150 S4) Technical Manual 17
18 PCI bus Features PCI IRQ Line x - Assignment of the PCI interrupts PCI IRQ Line x defines which ISA interrupts are used for the separate PCI slots. If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required. Multifunctional PCI boards or boards with an integrated PCI-to-PCI bridge can use several PCI interrupts (INTA#, INTB#, INTC#, INTD#). Monofunctional PCI boards (default) only use one PCI interrupt (INTA#) per PCI slot. The PCI interrupts INTA#, INTB#, INTC# and INTD# are available for each PCI slot. The same interrupt can be assigned simultaneously to several PCI boards. You should avoid this condition due to reduced performance. If you use a setting other than Auto, the Plug&Play functionality of the system BIOS for the corresponding PCI boards is deactivated. Auto The PCI interrupts are assigned automatically in accordance with the Plug&Play guidelines. Disabled No ISA interrupt is assigned to the PCI interrupt. 3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15 The selected ISA interrupt is assigned to the PCI interrupt. You may not select an ISA interrupt that is used by a component on the system board (e.g. controller) or an ISA board. 18 Technical Manual D2239 (TX150 S4)
19 Features PCI bus PCI INT LINE ICH Controller or slot INT Onboard controller Slot USB 1.1 L S A C N PCI PCI-X PCI-X PCI PCI PCIe PCIe S S x4 x1 U M I S P B (P 1st 2nd 3rd 4th B CI u X PXH-V 2.0 e s H ICH (ZCR PXH-V ICH ICH ICH ICH (I -V *) C *) H) 1 (A) x B D B D 2 (B) x C A C A 3 (C) D D B C A D B 4 (D) x C A C D B A 5 (E) x 6 (F) x B A C 7 (G) x A B D 8 (H) x x P 0 B D X 1 C A H 2 D B - V 3 A C IDSel *) only SCSI version D2239 (TX150 S4) Technical Manual 19
20 Screen resolution Features 3.4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board (with ATI VGA driver). Screen resolution 800x x x1024 Refresh rate 8, 16, 32 bpp 60/75/85 Hz The ATI VGA driver is supported by the operation systems Windows 2000 Server and Windows Server 2003, and by all LINUSX derivates. If you are using a different screen controller, you will find details of supported screen resolutions in the documentation supplied with the controller. 3.5 Temperature / system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status. The temperature and system monitoring are controlled by an onboard controller. The following functions are supported: Temperature monitoring Measurement of the processor and the inhouse temperature by an onboard sensor, measurement of the ambient temperature by a I²C temperature sensor. Fan monitoring Fans that are no longer available, blocked or sticky fans are detected. Fan control The fans are regulated according to temperature. 20 Technical Manual D2239 (TX150 S4)
21 Features Temperature / system monitoring Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated. Cover monitoring: Unauthorized opening of the cover is detected, even when the system is switched off. However, this will only be indicated when the system is switched on again System Event Log (SEL) All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a reboot via ServerView. D2239 (TX150 S4) Technical Manual 21
22 Interfaces and connectors Features 3.6 Interfaces and connectors Figure 4: Schematic view of the system board D SCSI version 1 = CPU fan 11 = Intrusion detection 2 = Floppy disk drive 12 = SMB1 (I²C temperature sensor) 3 = Front panel 13 = RSB LP power 4 = PC98 14 = IPMB 5 = IDE 15 = HDD activity 6 = Power supply 16 = Buzzer 7 = PSU 12V connector (CPU) 17 = System fan 1 8 = USB 3/4 18 = external ports 9 = System fan 2 19 = PWD SKIP/RCVR (jumper) 10 = SCSI U Technical Manual D2239 (TX150 S4)
23 Features Interfaces and connectors Figure 5: Schematic view of the system board D SATA version 1 = CPU fan 10b = SATA LED 2 = Floppy disk drive 11 = Intrusion detection 3 = Front panel 12 = SMB1 (I²C temperature sensor) 4 = PC98 13 = RSB LP power 5=IDE 14=IPMB 6 = Power supply 15 = HDD activity 7 = PSU 12V connector (CPU) 16 = Buzzer 8 = USB 3/4 17 = System fan 1 9 = System fan 2 18 = external ports 10a = SATA = PWD SKIP/RCVR (jumper) D2239 (TX150 S4) Technical Manual 23
24 Interfaces and connectors Features Settings with jumpers The following jumper settings are possible: Figure 6: Jumper settings default: PWD SKIP: RCVR: System BIOS recovery disabled/ Password skip disabled Skip password (enabled) Recover system BIOS (enabled) External connectors Figure 7: External ports of the system board D = PS/2 mouse port 6 = Serial port COM2 2 = Parallel port 7 = Serial port COM1 3 = LAN port 8 = PS/2 keyboard port 4=VGA port 9=ID LED 5 = USB port (1/2) 10 = Global Error LED 24 Technical Manual D2239 (TX150 S4)
25 Features Interfaces and connectors LEDs LED Indicator Meaning 9 Identify blue Server is identified via ServerView orange Indicates a prefailure 10 Global Error orange flashing Indicates a failure. Reasons for a failure may be: - overheating of one of the sensors - sensor defect - fan defect - CPU error - Software detected an error LAN connectors On this system board you will find one GbE Broadcom LAN controller BCM5721. This LAN controller supports the transfer rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller supports WOL function through Magic Package. It is also possible to boot a device without its own boot hard disk via LAN. Here Intel PXE is supported. The LAN port serves as management interface and is prepared for RemoteView. The LAN controller connectors are equipped with two LEDs (light emitting diode) indicating the transfer rate and the activity. D2239 (TX150 S4) Technical Manual 25
26 Interfaces and connectors Features 1 2 Figure 8: LAN connectors 1 LAN link/activity 2 LAN transfer rate green ON LAN connection OFF no LAN connection flashing LAN transfer green + yellow OFF transfer rate 10 Mbit/s (or no connection) green ON transfer rate 100 Mbit/s yellow ON transfer rate 1000 Mbit/s 26 Technical Manual D2239 (TX150 S4)
27 4 Replacing the lithium battery In order to save the system information permanently, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V ATENTION! The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2032). Do not throw lithium batteries into the trashcan. It must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The plus pole must be on the top! "! Figure 9: Replacing the lithium battery Ê Press the locking spring into direction of the arrow (1), so that the lithiumbattery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). D2239 (TX150 S4) Technical Manual 27
28
29 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board. ACPI Advanced Configuration and Power management Interface ASRR Automatic Server Recovery and Restart ATA BBU BIOS BMC Advanced Technology Attachment Battery Backup Unit Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM CPU DDR COMmunication port Central Processing Unit Double Data Rate DIMM Dual In-line Memory Module D2239 (TX150 S4) Technical Manual 29
30 Abbreviations DIP DMI Dual In-line Package Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD HPC ICE IDE IME IOOP Hot-plug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus 30 Technical Manual D2239 (TX150 S4)
31 Abbreviations IPMI LAN LED MPS NMI OEM OHCI OS PCI PDA PIO PLD Intelligent Platform Management Interface Local Area Network Light Emitting Diode Multi Processor Specification Non Maskable Interrupt Original Equipment Manufacturer Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) PWM Puls Wide Modulation D2239 (TX150 S4) Technical Manual 31
32 Abbreviations PXE RAID RSB RST RTC SATA SCSI Preboot execution Environment Redundant Array of Independent Disks Remote Service Board ReSeT Real Time Clock Serial Advanced Technology Attachment Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB SMM SMP System Management Bus Server Management Mode Symmetrically Multi Processing UHCI Unified Host Controller Interface 32 Technical Manual D2239 (TX150 S4)
33 Abbreviations USB VGA VRD VRM WfM WOL Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN D2239 (TX150 S4) Technical Manual 33
34
35 Fujitsu Siemens Computers GmbH User Documentation München Germany Fax: (++49) 700 / Comments Suggestions Corrections [email protected] Submitted by Comments on System Board D2239 for TX150 S4 D2239 (TX150 S4)
36
37 Fujitsu Siemens Computers GmbH User Documentation München Germany Fax: (++49) 700 / Comments Suggestions Corrections [email protected] Submitted by Comments on System Board D2239 for TX150 S4 D2239 (TX150 S4)
38
39 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009
System Board D2559 for TX150 S6. Technical Manual
System Board D2559 for TX150 S6 Technical Manual Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
System board D1979 for TX150 S3
Produktfamilie System board D1979 for TX150 S3 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: [email protected] Tel.: (089) 61001-??? Fax: (++49)
System board D2179 for Econel 100
PRIMERGY System board D2179 for Econel 100 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: [email protected] Tel.: (0 89) 61 001-155 Fax: (++49)
System board D2532 for RX100 S4
PRIMERGY System board D2532 for RX100 S4 Technical Manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: [email protected] Tel.: (089) 61001-155 Fax: (++49) 700
System Board D2530 for Econel 200 S2
PRIMERGY System Board D2530 for Econel 200 S2 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-155 Fax:
System board D1899/D2099 for TX300 S2
Produktfamilie System board D1899/D2099 for TX300 S2 Technical manual Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: [email protected] Tel.: (089) 61001-160
System Board D2779 for PRIMERGY TX100 S2
Technical Manual - English System Board D2779 for PRIMERGY TX100 S2 Technical Manual Edition June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
O D B C / R O C K E T ( B S 2 0 0 0 / O S D ) V 5. 0 F O R S E S A M / S Q L D A T E : F E B R U A R Y 2 0 0 8 *2 R E L E A S E N O T I C E
O D B C / R O C K E T ( B S 2 0 0 0 / O S D ) V 5. 0 F O R S E S A M / S Q L D A T E : F E B R U A R Y 2 0 0 8 *2 R E L E A S E N O T I C E RELEASE NOTICE ODBC/ROCKET (BS2000/OSD) V 5.0 1 General.......................
Introduction U41241-J-Z125-1-76 1
Introduction The rapid expansion of the Internet and increasingly mobile and more powerful end devices are the driving force behind development in information and communication technology. This process
TS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
PRIMERGY TX100 S1. Options Guide
PRIMERGY TX100 S1 Options Guide Edition August 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
System Board D3009 for PRIMERGY TX100 S3
Technical Manual - English System Board D3009 for PRIMERGY TX100 S3 Technical Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like
System Board D2863 for PRIMERGY RX100 S6
Technical Manual - English System Board D2863 for PRIMERGY RX100 S6 Technical Manual Edition February 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
Intel Desktop Board D925XECV2 Specification Update
Intel Desktop Board D925XECV2 Specification Update Release Date: July 2006 Order Number: C94210-005US The Intel Desktop Board D925XECV2 may contain design defects or errors known as errata, which may cause
PRIMERGY Econel 50 Server System
PRIMERGY PRIMERGY Econel 50 Server System Service Supplement Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-157 Fax: 0 700
Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I
Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable
Manual OS Installation
CA92276-8158 EN-09 ECONEL 100 S2 / TX120 / TX150 S6 / TX300 S4 / RX100 S5 / RX200 S4 / RX300 S4 / RX600 S4 Manual OS Installation Before Reading This Manual Before Reading This Manual Remarks Symbols Symbols
How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X
System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside
Tipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
BIOS Update Release Notes
PRODUCTS: D975XBX (Standard BIOS) BIOS Update Release Notes BIOS Version 1351 August 21, 2006 BX97510J.86A.1351.2006.0821.1744 Fixed issue where operating system CD installation caused blue screen. Resolved
EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0
EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0 Copyright 2011 ECDL Foundation All rights reserved. No part of this publication may be reproduced in any form except as permitted by ECDL
85MIV2 / 85MIV2-L -- Components Locations
Chapter Specification 85MIV2 / 85MIV2-L -- Components Locations RJ45 LAN Connector for 85MIV2-L only PS/2 Peripheral Mouse (on top) Power PS/2 K/B(underside) RJ45 (on top) +2V Power USB0 (middle) USB(underside)
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
System Configuration and Order-information Guide ECONEL 100 S2. March 2009
System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside
H97M-E/CSM. Chipset. Memory. Graphic. Expansion Slots. Storage
H97M-E/CSM Intel Socket 1150 for the 5 th /New 4 th /4 th Generation Core i7/core i5/core i3/pentium /Celeron Processors Supports Intel 22 nm CPU Supports Intel Turbo Boost Technology 2.0 * The Intel Turbo
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Datasheet for Red Hat certification PRIMERGY CX1000 is a new product category within the PRIMERGY x86 server family. Its focus
EVGA Z97 Classified Specs and Initial Installation (Part 1)
User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500
Pages: Data Sheet The wide-ranging home office and multimedia PC Issue: November 2009 The wide-ranging is the ideal home office and multimedia PC for families. Equipped with powerful Intel processor and
SBI-7125B-T1 Blade Module RAID Setup Procedure
SBI-7125B-T1 Blade Module RAID Setup Procedure Revison 1.0 SBI-7125B-T1 Blade Module RAID Setup Procedure The information in this User s Manual has been carefully reviewed and is believed to be accurate.
Mother Board Component
Mother Board Component Explain Introduction Mother Board Component 1.Clock Generator 2. CPU socket 3. Memory Socket Memory error checking 4. ROM Bios 5. CMOS Ram 6. Battery 7. Chipset 8. Expansion Slot
System Board D2619-N for PRIMERGY RX/TX300 S6
Technical Manual - English System Board D2619-N for PRIMERGY RX/TX300 S6 Technical Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
Configuring Memory on the HP Business Desktop dx5150
Configuring Memory on the HP Business Desktop dx5150 Abstract... 2 Glossary of Terms... 2 Introduction... 2 Main Memory Configuration... 3 Single-channel vs. Dual-channel... 3 Memory Type and Speed...
H ARDWARE C ONSIDERATIONS
H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Compaq ProLiant ML370 G2 This document provides information on specific system hardware required for running Sidewinder firewall software on
Getting Started. Chapter 1
Chapter 1 Getting Started Thank you for choosing the 7728 v2.x Series Micro-ATX mainboard. The 7728 v2.x Series mainboards are based on Intel H61 chipsets for optimal system efficiency. Designed to fit
IBM Europe Announcement ZG08-0232, dated March 11, 2008
IBM Europe Announcement ZG08-0232, dated March 11, 2008 IBM System x3450 servers feature fast Intel Xeon 2.80 GHz/1600 MHz, 3.0 GHz/1600 MHz, both with 12 MB L2, and 3.4 GHz/1600 MHz, with 6 MB L2 processors,
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DG31PR, DG31PRBR (Standard BIOS) BIOS Version 0070 About This Release: February 8, 2010 Integrated Graphics Option ROM Revision: PXE LAN Option ROM Revision: Improved
Cisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
SYSTEM BOARD D1107 ADDITIONAL TECHNICAL MANUAL
SYSTEM BOARD D07 ADDITIONAL TECHNICAL MANUAL Is there...... any technical problem or other question you need clarified? Please contact: Our Hotline: Mo-Fr: 8 a.m. - 6 p.m. Sat: 9 a.m. - 2 p.m. Tel.: ++49
Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor
Intel Desktop Board DB75EN MicroATX Form Factor product brief Built for Business: Intel Desktop Board DB75EN maximizes employee productivity, PC performance, and data security with Intel Small Business
Data Sheet Fujitsu ESPRIMO P2440 Desktop PC
Data Sheet Fujitsu ESPRIMO P2440 Desktop PC Your immediately available Office PC ESPRIMO P2440 Equipped with proven AMD technology the ESPRIMO P2440 is the best choice for cost-conscious buyers in small
HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001
HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject
H ARDWARE C ONSIDERATIONS
H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Dell Precision 530 This document provides information on specific system hardware required for running Sidewinder firewall software on a Dell
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
Z97-PRO GAMER Especificaciones
Z97-PRO GAMER Especificaciones CPU Intel Socket 1150 for the 5 th /New 4 th /4 th Generation Core i7/core i5/core i3/pentium /Celeron Processors Supports Intel 22 nm CPU Supports Intel Turbo Boost Technology
Manual IB-3620 Series
IB-RD3620SU3 1 IB-3620U3 CONTENT 1. Introduction... 3 1.1 General Information... 3 2. Hardware IB-3620 Series... 4 2.1 LED Indication / Button Front Panel... 4 2.2 Rear View... 5 3. HDD Installation...
AwardBIOS Setup Utility
AwardBIOS Setup Utility Modifications to the BIOS Setup settings should be performed by advanced users only. Setting items to incorrect values may cause your system to malfunction. Introducing BIOS Setup...2
BIOS Update Release Notes
PRODUCTS: D945GCCR (Standard BIOS) BIOS Update Release Notes BIOS Version 0060 August 8, 2008 CR94510J.86A.0060.2008.0807.1918 Fixed issue where new BIOS SETUP settings may contain random data when using
C440GX+ System Event Log (SEL) Messages
C440GX+ System Event Log (SEL) Messages Revision 0.40 4/15/99 Revision Information Revision Date Change 0.40 4/15/99 Changed BIOS Events 0C EF E7 20, 0C EF E7 21 to 0C EF E7 40, 0C EF E7 41 Disclaimers
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
This chapter explains how to update device drivers and apply hotfix.
MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview
Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor
Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DH55TC, DH55HC, DH55PJ (Standard BIOS) BIOS Version 0040 - TCIBX10H.86A.0040.2010.1018.1100 October 18, 2010 Integrated Graphics Option ROM Revision on HC/TC: 2017 PC
Fujitsu PRIMERGY BX600 S3 Blade Server
Datasheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem - the ideal platform for branch offices and medium-sized companies The PRIMERGY BX Blade Servers are the ideal choice for the data
Areas Covered. PRIMERGY BX620 S4 Server Blade User s Guide
PRIMERGY BX620 S4 Server Blade User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read this section.
Cisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Monthly Specification Update
Intel Server Board S1200BTLR Intel Server Board S1200BTSR Intel Server Board S1200BTLRM Intel Server System R1304BTLSFANR Intel Server System R1304BTSSFANR Intel Server System R1304BTLSHBNR Intel Server
Data Sheet ESPRIMO P3510. Your flexible economic PC ESPRIMO P3510
Pages: Data Sheet Your flexible economic PC Issue: September 2009 The is the right choice for major customers requiring the latest standard features. This Microtower PC is the ultimate balance between
(AOpen reserves the right to revise all the specifications and information contained in this document which is subject to change without notice.
(AOpen reserves the right to revise all the specifications and information contained in this document which is subject to change without notice.) PS/2 Mouse Connector USB2.0 Ports SPP/EPP/ECP Parallel
System Installation. 3-1 Socket 370 Celeron/Pentium-III Processor. Installing S370 CPU. Removing CPU. Configuring System Bus
System Installation This chapter provides you with instructions to set up your system. The additional information is enclosed to help you set up onboard PCI device and handle WDT operation in software
Intel N440BX Server System Event Log (SEL) Error Messages
Intel N440BX Server System Event Log (SEL) Error Messages Revision 1.00 5/11/98 Copyright 1998 Intel Corporation DISCLAIMERS Information in this document is provided in connection with Intel products.
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DH61BE, DH61CR, DH61DL, DH61WW, DH61SA, DH61ZE (Standard BIOS) BIOS Version 0120 - BEH6110H.86A.0120.2013.1112.1412 Date: November 12, 2013 ME Firmware: Ignition SKU
Glossary. Active/Active Application Failover
Glossary A Active/Active Application Failover A failover scenario in which an application that is running on one server fails over to another server that is running the same application. Active/Passive
Mini server, BIG performance AC100
Mini server, BIG performance AC100 The AC100 is the perfect first server for your small business. This tiny dynamo packs a wealth of enterprise level features including Intel Xeon processors, ECC memory,
Cisco MCS 7845-I2 Unified Communications Manager Appliance
Cisco MCS 7845-I2 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Cisco NAC Appliance Hardware Platforms
1 CHAPTER This chapter provides general information on the Cisco NAC Appliance network access control system, as well as hardware specifications for all Clean Access Manager (CAM) and Clean Access Server
A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.
Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density
Acer AT110 F2 Specifications
Product overview The AT110 F2 delivers true server-class features and expandability along with best price-performance technology to assure the success of your small-sized business. This single-socket tower
PRIMERGY TX150 S3 Server System
PRIMERGY PRIMERGY TX150 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001155 Fax: (++49)
Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server
Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Enter the world of PRIMERGY TX servers FUJITSU Server PRIMERGY systems provide the most
This chapter explains a preparation for the use of RemoteControlService.
ServerView User's Guide (For RemoteControlService) Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of RemoteControlService
PS/2 Keyboard Connector
PS/2 Mouse Connector SPP/EPP/ECP Parallel Port RJ45 LAN Jack (for AX45F-4DL, AX45F-4DN and AX45F-4D Max) Line-In USB 2.0 Ports Speaker Out MIC-In Realtek Gigabit LAN chip (for AX45F-4D Max and AX45F-4DL)
Computer Setup (F10) Utility Guide Evo Desktop Family Evo Workstation Family
b Computer Setup (F10) Utility Guide Evo Desktop Family Evo Workstation Family Document Part Number: 215867-004 May 2002 This guide provides instructions on how to use Computer Setup. This tool is used
E2437. Motherboard. Troubleshooting Guide Q & First Edition September 2006 Copyright 2006 ASUSTeK COMPUTER INC. All Rights Reserved.
E2437 Motherboard Troubleshooting Guide Q & A First Edition September 2006 Copyright 2006 ASUSTeK COMPUTER INC. All Rights Reserved. 15G063644020 Motherboard troubleshooting This guide provides some solutions
Installation ServerView ESXi CIM Provider V6.12
Installation Guide - English FUJITSU Software ServerView Suite Installation ServerView ESXi CIM Provider V6.12 VMware vsphere Hypervisor server (ESXi) as of version 4.0 Edition February 2013 Comments Suggestions
Datasheet. The cost-optimized all-rounder
Datasheet Fujitsu Thin Client The cost-optimized all-rounder The compact and cost-efficient is your perfect entry thin client for Server-Based Computing and Virtual Workplace solutions. High energy-efficiency
Intel RAID Controller Troubleshooting Guide
Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting
Motherboard Specifications, A8M2N-LA (Naos)
HP Customer Care > Compaq Presario SR2010NX Desktop PC Motherboard Specifications, A8M2N-LA (Naos) Support details» Motherboard specifications table» Motherboard layout and photos» Clearing the BIOS settings»
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
DigiPoS Store Solutions: Retail Blade
DigiPoS Store Solutions: Retail Blade Retail Blade: The facts The DigiPoS Store Solutions Group is a global business operating exclusively in the field of Retail Technology, Software and Support Services.
SB9011D All-in-one Touch POS Terminal USER MANUAL
SB9011D All-in-one Touch POS Terminal USER MANUAL Table of Contents 1 Overview... 2 1.1 Safety Information... 2 1.2 Electromagnetic compatibility statement... 3 2 Installation Guide... 4 2.1 Appearances...
SATA II-150 PCI Quick Installation Guide
SATA II-150 PCI Quick Installation Guide Introducing the SATA II-150 PCI The SATA II-150 PCI is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI enabled systems. Features
McAfee Firewall Enterprise
Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,
Fujitsu PRIMERGY BX920 S2 Dual-Socket Server
Datasheet Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Blade Datasheet for Red Hat certification Universal Dual-Sockel Server Blade with high computing and I/O performance in a small form factor The PRIMERGY
IPN73-BA Motherboard layout reference Contents
IPN73-BA Motherboard layout reference Contents Specifications summary Motherboard layout Rear panel connectors Function selectors Status indicators Internal connectors February 2008 Specifications summary
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
Fujitsu LifeBook S Series
Fujitsu LifeBook S Series BIOS Guide LifeBook S Series Model: S7220 Document Date: 07/08/2008 Document Part Number: FPC58-1920-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook S Series BIOS S Series
Dell PowerEdge T110 II Systems. Owner s Manual. Regulatory Model E11S Series Regulatory Type E11S002
Dell PowerEdge T110 II Systems Owner s Manual Regulatory Model E11S Series Regulatory Type E11S002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better
Getting Started. Chapter 1
Chapter 1 Getting Started Thank you for choosing the 7681 v3.2 Series (MS7681) ATX mainboard. The series mainboards are based on Intel P67 chipsets for optimal system efficiency. Designed to fit the advanced
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
D2619 BIOS Setup Utility for PRIMERGY RX300 S5 and TX300 S5. Reference Manual
D2619 BIOS Setup Utility for PRIMERGY RX300 S5 and TX300 S5 Reference Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this
System Release Notes Express5800/320LB System Release Notes
System Release Notes Express5800/320LB System Release Notes PN: 455-01681-004 2 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related
Electronic Emission Notices
1 Electronic Emission Notices Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC
Computer Setup (F10) Utility Guide Business PCs
Computer Setup (F10) Utility Guide Business PCs Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
General FAQ s E-Pos Systems.
General FAQ s E-Pos Systems. Q1. To install ELO touch screen, why does E-Touch Pro (B55 M/B) work fine in Windows but fail in DOS? Q2. Why can't the Touch screen driver work on Win XP? Q3. I installed
