THERMOSTOP24 System PORTALEX ALUMINIO SA
|
|
- Madlyn Fitzgerald
- 8 years ago
- Views:
Transcription
1 THERMOSTOP24 System
2 is engaged in the extrusion of aluminium profiles of several sizes with more or less complexity, depending on the client's needs. The extrusion of aluminium allows all freedom of design as to continuously meet different needs. THERMOSTOP24 Door Post System, is a thermal break system composed by thermal improved profiles due to the mechanical link of extruded aluminium profiles with polyamides bars of 24 mm, strengthened with fibreglass. Design to meet the technical requirements of Building systems of quality, the THERMOSTOP24 Door Post System, offers high levels of acoustic and thermal comfort, promoting the well being, the greater conservation of resources and the consequently environment respect. THERMOSTOP24 Door Post System uses the available equipment and accessories on the market it's characterized and classified in accordance with Standard NP EN :2008, standard of CE Marking. Constructive Solutions, dimensions of profiles and glass: Windows and doors of two, three and four leaves. Depth of the profile rim: 54.4 mm Depth of the profile sheet: 64.6mm Double glass till 36 mm Classification and Characterization: Window 2 leaves with 1800 mm x 00 mm Solution of perimeter leaft Double glass Air tightness: Class 4 Watertight: Class 9A Wind pressure resistance: C3 Thermal transmission coefficient: Uw = 3.1W / (m² K) Uf = 3.0 W /(m² K) Acoustic Performance: RW= 37 (-2; -4) db Classification and Characterization: Window 2 leaves with 1230 mm x 1480 mm Solution of perimeter leaft Double glass Air tightness: Class 4 Watertight: Class 9A Wind pressure resistance: C3 Thermal transmission coefficient: Uw = 2.9W / (m² K) Uf = 3.0 W /(m² K) Acoustic Performance: RW = 37 (-2; -4) db Presentation and characterization 01
3 Index Presentation an characterization 01 General index 02 Visual index 03 Profiles. Rims 07. Rims and stuctural profiles 10. Transons 11. s. Various 14 Details 15 Acessories 17 Nomenclature 20 General index 02
4 Drawing reference Denomination Weigth kg/m Tratement area m 2 /m Inertia cm 4 Page TS0124 Fixed rim 0,857 0,347 Ix = 14,74 Iy = 4,73 08 TS0224 Fixed rim 1,249 0,412 Ix = 31,15 Iy = 8,49 10 TS0324 0,956 0,390 Ix = 20,03 Iy = 6,39 08 TS0424 1,067 0,388 Ix =,50 Iy = 8,90 07 TS0524 1,314 0,484 Ix = 27,55 Iy = 22,09 08 TS0624 1,432 0,480 Ix = 28,99 Iy = 27,00 07 TS0724 False central panel 1,009 0,389 Ix = 17,40 Iy =6,15 12 TS0824 Transon 0,901 0,386 Ix = 14,43 Iy = 6,50 12 TS0924 Transon 1,186 0,445 Ix = 18,77 Iy =,89 12 TS1024 Transon 1,252 0,448 Ix = 23,87 Iy = 14,05 12 Visual index 03
5 Drawing reference Denomination Weigth kg/m Tratement area m 2 /m Inertia cm 4 Page TS1124 Transon 2,264 0,669 Ix = 38,20 Iy = 144,4 11 TS1224 Transon 2,475 0,712 Ix = 48,55 Iy = 153,7 11 TS24 Fixed rim 1,049 0,387 Ix = 17,78 Iy = 10,31 08 TS1424 1,326 0,438 Ix = 25,56 Iy = 16,69 07 TS1524 Condensation profile 0,9 0,355 Ix = 2,01 Iy = 22,29 14 TS1624 Stuctural profile 1,509 0,497 Ix = 35,93 Iy = 15,56 10 TS1724 Fixed rim 0,991 0,4 Ix =,50 Iy = 9,71 07 TS1824 1,261 0,423 Ix = 26,83 Iy = 12,60 09 TS1924 1,493 0,472 Ix = 30,82 Iy = 22,30 09 TS2224 Fixed rim 1,383 0,486 Ix = 41,95 Iy =,63 10 Visual index 04
6 Drawing reference Denomination Weigth kg/m Tratement area m 2 /m Inertia cm 4 Page TS2324 2,446 0,634 Ix = 49,14 Iy = 104,8 09 P01504 Drip profile 0,176 0,083 Ix = 0,10 Iy = 0,36 14 P03184 Bar 0,148 0,048 Ix = 0,01 Iy = 0,18 14 P ,266 0,170 Ix = 0,73 Iy = 0,61 P ,2 0,7 Ix = 0,55 Iy = 0,22 P ,288 0,185 Ix = 0,77 Iy = 1,01 P ,228 0,147 Ix = 0,62 Iy = 0,37 P ,209 0,124 Ix = 0,54 Iy = 0,51 P ,164 0,096 Ix = 0,38 Iy = 0,11 P ,220 0,129 Ix = 0,51 Iy = 0, Visual index 05
7 Drawing reference Denomination Weigth kg/m Tratement area m 2 /m Inertia cm 4 Page P ,178 0,104 Ix = 0,44 Iy = 0,15 P ,225 0,145 Ix = 0,60 Iy = 0,24 P ,241 0,155 Ix = 0,67 Iy = 0,44 P ,255 0,158 Ix = 0,65 Iy = 0,42 P ,270 0,158 Ix = 0,72 Iy = 0,46 P043 0,262 0,168 Ix = 0,73 Iy = 0,63 P04543 Inferior fase panel 0,425 0,224 Ix = 0,89 Iy = 2,30 14 Note: the inertia moments presented are calculated based on the axle represented here Y X with the profile positon indicated in this index. Visual index 06
8 TS 0424 TS TS 1424 TS 1724 Fixed rim Rims 07
9 TS 0124 Fixed rim TS TS 0524 TS 24 Fixed rim Rims 08
10 TS 1924 TS TS 2324 Rims 09
11 TS 0224 Fixed rim TS 1624 Structural curve profile TS 2224 Fixed rim Rims and structural profiles 10
12 TS 1124 Transon TS 1224 Transon Large transons 11
13 TS0724 Postiço Central TS0824 Travessa TS 0924 Transon TS 1024 Transon Transons 12
14 P03659 P03677 P P03660 P03829 P P03671 P03884 P P03672 P P03676 P03886 s
15 TS 1524 Condensation profile P01504 Drip profile P03184 Bar 38.7 P04543 Inferio false panel Various 14
16 THERMOSTOP24 Door Post System 27.8 TS0124 TS0424 P03672 P03672 Interior 27.8 TS0124 Exterior Without scale Details 15
17 4.5 TS TS0424 P P03672 P03672 TS TS0424 Details 16
18 Drawing Denomination Reference Contacts Notes Cutting tool Cutting tool for alignament square Cutting tool Structural square Structural square Structural square External alignement square Alignement square Internal alignement square Hinge THERMOSTOP THERMOSTOP nº A 2535A P C CE2F M.J. BRANCO, Lda. Marina Branco Tel: Fax: geral@mjbranco.pt M.J. BRANCO, Lda. Marina Branco Tel: Fax: geral@mjbranco.pt CUNCORTAVE, Lda. Sérgio Santos Tel: /7 Fax: geral@cuncortave.com PAULO S. AGUIAR, Un. Lda Paulo Aguiar Tel: Fax: geralpa@iol.pt PAULO S. AGUIAR, Un. Lda Paulo Aguiar Tel: Fax: geralpa@iol.pt PAULO S. AGUIAR, Un. Lda Paulo Aguiar Tel: Fax: geralpa@iol.pt ALUALPHA, S.A. Rui Ribeiro Tel: Fax: info@alualpha.pt POLISMAR, Lda. Mário Rodrigues Tel: Fax: mariorodrigues@polismar.pt PAULO S. AGUIAR, Un. Lda Paulo Aguiar Tel: Fax: geralpa@iol.pt ALUALPHA, S.A. Rui Ribeiro Tel: Fax: info@alualpha.pt Acessories 17
19 Drawing Denomination Reference Contacts Notes Oscllatig opening Latch Wedge rim Wedge glass Wedge glass Leak Top stile for false central panel Central seall Seal for fixed rim Sel for mobile rim Kit OBG P P0006-TE1 P P E1 P E1 ALUALPHA, S.A. Rui Ribeiro Tel: Fax: info@alualpha.pt ALUALPHA, S.A. Rui Ribeiro Tel: Fax: info@alualpha.pt POLISMAR, Lda. Mário Rodrigues Tel: Fax: mariorodrigues@polismar.pt POLISMAR, Lda. Mário Rodrigues Tel: Fax: mariorodrigues@polismar.pt POLISMAR, Lda. Mário Rodrigues Tel: Fax: mariorodrigues@polismar.pt POLISMAR, Lda. Mário Rodrigues Tel: Fax: mariorodrigues@polismar.pt PERVEDANT Tel: Fax: info@pervedant.com PERVEDANT Tel: Fax: info@pervedant.com PERVEDANT Tel: Fax: info@pervedant.com PERVEDANT Tel: Fax: info@pervedant.com Acessories 18
20 Drawing Denomination Reference Contacts Notes PERVEDANT External glass seal Internal glass seal Internal glass seal Internal glass seal P E1 P E1 P E1 P E1 Tel: Fax: PERVEDANT Tel: Fax: PERVEDANT Tel: Fax: PERVEDANT Tel: Fax: Glue Wurth Silicone Wurth Acessories 19
21 1 - Lintel 2 - Fanlight 3 - Frame-head 4 - Transon 5 - Doorleaf or casement or sash 6 - Frame-jamb 7/12 - Threshold 7 - Sublight 8 - Toprail 9 - Stile Botton rail 11 - Mullion 12 - Threshold - Mullion Denominations of windows and doors according NP EN 12519: Nomenclature 20
22 This catalogue might be subject to modifications due to technical reason, without previous notice. Every order must be subjected to confirmation directly with our services. Head office: Estrada de São Marcos, nº CACÉM - PORTUGAL Tel.: (+351) Fax: (+351) Fax comercial: (+351) website: Added Value Activities: Rua da República da Coreia, nº SINTRA - PORTUGAL Tel.: (+351) Fax: (+351) Fax comercial: (+351) Website: Vat number: PT Trade Register of Sintra nº 1709 Share Capital ,00
All the above mentioned technical characteristics of the MU 2500 Thermal system indemnify its air and water tightness.
MU INTRODUCTION MU 2500 Thermal,.,,,,. The MU 2500 Thermal system can be used for doors and windows in domestic and commercial applications such as houses, villas, big complexes of flats and offices.
More informationSL30-ISO PROFILE SYSTEM
AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention
More informationUnbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
More informationΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΥΣΤΗΜΑΤΑ ΑΛΟΥΜΙΝΙΟΥ ARCHITECTURAL ALUMINIUM SYSTEMS
ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΥΣΤΗΜΑΤΑ ΑΛΟΥΜΙΝΙΟΥ ARCHITECTURAL ALUMINIUM SYSTEMS NORMAL SLIDING and SLIDING WITH THERMAL BREAK A L U M IN IU M S Y S T E M S 32 SERIES 32 SLIDING. : 9045 815 gr/m 475 mm -25-25 - FOR
More informationInstallation Detailed installation instructions are provided which should be strictly followed.
Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial
More informationinformation information
Technicalinformation Technicalinformation technicalinformation SYSTEM 40C GENERAL GROPERTIES 1 Glazing: from 4 to 22 mm 2 E.P.D.M. Sealing Gasket 3 Efficent drainage of the vent section 4 Efficent chamber
More informationAvantis 75. Windows & Doors. Sapa Building System
Avantis 75 Windows & Doors Sapa Building System Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationV80 HEAD DETAIL - SECTION VIEW DRAWING SCALE 1:2. Dwg. No. V10101. 13mm min. 85mm. 72mm 95mm 65mm. 26mm. 10mm 60mm 75mm. 135mm.
13mm min. 72mm 95mm 65mm 85mm 26mm 10mm 60mm 75mm 135mm 145mm V80 HEAD DETAIL - SECTION VIEW Dwg. No. V10101 Manually operated blind with gearbox showing 90 & 45 degree crank penetrations in section view.
More informationanatomy of a window lintel architrave inner staff bead top rail lintel upper sash glazing bar meeting rails horn pane lower sash reveal
windows introduction Windows make a vital contribution to the character and appearance of historic buildings.the insertion of modern windows can completely ruin the look of a traditional building and considerably
More informationPlaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
More informationFire-rated Aluminum Doors
Fire-rated Aluminum Doors Langebjergvænget 13 ALUFLAM has pioneered the innovative solution to what was long considered an impossible dream (and a barrier to truly beautiful commercial architectural design),
More informationConfort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
More informationGlass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
More informationSeries 602 MAGNUM Sliding Window DESIGNER SERIES
Series 602 DESIGNER SERIES DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 DESIGNER SERIES Series 602 KEY EATURES / PERORMANCE CHARACTERISTICS Scale: NOT TO SCALE Designed to complement our existing high quality
More informationWindows, French doors, folding windows, terrace doors SFB 1074 with low U-values
Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values SFB 1074 is available in two versions. In the first version the profiles are insulated with 30 mm glass fibre reinforced
More informationQuality Building Products for over 50 Years
Light Commercial Quality Building Products for over 50 Years Harvey Building Products is a leading manufacturer and distributor of high quality building products. We manufacture a complete line of superior
More informationALUMINIUM SYSTEMS S.A.
ΡΟΛΑ ΑΠΛΑ και ΘΕΡΜΟΜΟΝΩΤΙΚΑ NORMAL & THERMAL INSULATING ROLLER SHUTTERS ALUMINIUM SYSTEMS S.A. ALUMINIUM SYSTEMS S.A C.AL.COM,.,,,.,,.. C.AL.COM. C.AL.COM. About us C.AL.COM is a modern dynamic commercial
More informationWOODEN WINDOWS CATALOGUE. www.bako-okna.pl
CATALOGUE MATERIAL Dear Sirs, Pine - preferably selected raw material for production of windows. Pine has a bright fresh colour, durability, excellent resistance to weather conditions and excellent thermal
More informationCDW Systems Ltd Contemporary Doors & Windows
CDW Systems Ltd Contemporary Doors & Windows The comprehensive product overview A complete specification guide to CDW Systems range of Aluminium windows, doors and curtain walling for commercial and residential
More informationEvidence of Performance Resistance to wind load Watertightness Air permeability
Evidence of Performance Resistance to wind load Watertightness Air permeability Test Report 102 43093/1e Client Product YILDIZPEN PLASTIK SAN. VE TIC. LTD. STI. A.O.S.B 10039 Street No:18 Çigli Izmir Turkey
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationEN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics
More informationPlaisance 50. Windows and doors. Sapa Building System
Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More informationWINDOWS THE HEAT TRANSFER COEFFICIENT IN DIFFERENT TYPES OF WINDOWS
Part-financed by the European Union (European Regional Development Fund and European Neighbourhood and Partnership Instrument) WINDOWS THE HEAT TRANSFER COEFFICIENT IN DIFFERENT TYPES OF WINDOWS Krzysztof
More informationInnovation Beyond Double Glazing
Innovation Beyond Double Glazing FIREGUARD 40 TM SERIES Innovation driven by passion On Guard NEW MIGLAS FIREGUARD 40 TM FIRST FULLY TESTED UNSCREENED BUSHFIRE RESISTANCE WINDOW FIRST WINDOW USING VIRIDIAN
More informationiku windows the intelligent self cleaning window AUTOMATIC system
iku windows is a aluminium sliding window system with two rails and double thermal breakage. By adding the iku box underneath the window sill it becomes an intelligent window. Functions Automatic opening
More informationSpecification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.
Uniclass L411 +L413:P7114 EPIC D11 +D13:X725 CI/SfB (31.4)+(31.5) Xn6 9/11 SmartSash A BRAND OF THE VEKA UK GROUP Specification Guide Fenestration Solutions for Public Sector & Commercial Applications
More informationAluminium systems profile selection
Aluminium systems profile selection The purpose of this document is to summarise the way that aluminium profile selection should be made, based on the strength requirements for each application. Curtain
More informationnano led THE GREEN LIGHT
nano led THE GREEN LIGHT nano led CHARACTERISTICS - LUMINAIRE Luminaire tightness level: IP 66 (*) Impact resistance: IK 08 (**) Nominal voltage: 230 V - 50 Hz Electrical class: II (*) Weight (empty):
More informationProduct information. Schüco Window AWS 65. 03.2009/Web Schüco AWS 65 1-11
Schüco Window AWS 65 The basic window system, Schüco Window AWS 65, with a comprehensive range for imaginative designs, is particularly suitable for block constructions with a basic depth of 65 mm. Features
More informationThe answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe
Order No. 2 02 130270-0310.KA profine GmbH Kömmerling Kunststoffe Postfach 2165 66929 Pirmasens Germany Tel. +49 6331 56-0 Fax +49 6331 56-2475 E-mail: info@koemmerling.de Internet: www.koemmerling.de
More informationPlanet Frameless Glazing. Planet 20 frameless glass swing door
Planet Frameless Glazing Planet 20 frameless glass swing door Contents Introduction Pg 2 Planet 20 - Single Glazing Pg 3-7 Planet 100 - Double Glazing Pg 8-12 Joint Options Pg13 Sectional Drawings for
More information581 Double Hung. Features. Windows 581 Double Hung. Options. Limitations
581 Double Hung Features Windows 581 Double Hung The series 581 double hung window offers superb ventilation control and easy, rattle free operation. Whether renovating your existing home or building a
More informationAKRAPLAST Sistemi S.p.A. - I - 20026 Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) 02 35 13 91 1 - Fax: (+39) 02 35 13 91 50 - E-mail:
Choose between alternatives marked by SPECIFICATION TEXT Wall; Northlight; realised with modular system type AKRAPAN by Akraplast Sistemi, composed of: 1) UV protected multi-wall polycarbonate panels with
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationEvidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No. 15-003655-PR01. ift Rosenheim 16.12.2015
Evidence of Performance Test Report No. 15-003655-PR01 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features Alüminyum San. Tic.
More informationUniversal systems for frameless doors
EN Universal systems for frameless doors Xinnix Door Systems designs, creates and manufactures systems for internal doors. With our construction elements, it is possible to obtain easily an elegant and
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More informationTOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.
NOTE: 2.4m high sliding doors are only available in certain configurations and sizes. Eagle Sidelights & Toplights Sidelights and Toplights are designed to clip onto the Eagle patio door system. The Sidelights
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationThe Warm Edge for insulating glass
The Warm Edge for insulating glass 1. 3. SGGSWISSPACER 2. 4. The best product on the market by quite an edge Energy saving Lower heating costs through better insulation: the thermally improved spacer SGG
More informationLight Architecture. Colors Sweden. Light
Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationPrefabricated building PVC vertical sliding window
Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located
More informationAMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY
PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall
More informationTested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)
THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types
More informationFire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
More informationMIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida
Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B8049.01-401-18 Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida PRODUCT TYPE: Aluminum Storefront with Double Doors SERIES/MODEL:
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationThe complete answer to secondary glazing. High performance secondary glazing solutions for new and refurbished buildings
The complete answer to secondary glazing High performance secondary glazing solutions for new and refurbished buildings add extra performance with secondary glazing systems Secondary glazing is a fully
More informationASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: 6010. TYPE: Single Hung Window
ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT Rendered to: MGM INDUSTRIES SERIES/MODEL: 6010 TYPE: Single Hung Window Summary of Test Results Data File No. Glazing (Nominal Dimensions) STC OITC B2706.01
More informationHow To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
More informationInstallation Window Building In Details
Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers
More informationSash Window Specialist
Sash Window Specialist ADVANCED SOLUTIONS FOR HISTORIC WINDOWS North West - UK Ged Barnes E-Mail : ged@sashwindowspecialist.com Tel: 01204 708650 Mobile: 07958 736 454 W.A. - Australia Simon Free E-Mail:
More informationTRADITIONAL CASEMENT WINDOWS
TRADITIONAL CASEMENT WINDOWS Design Guide Timber casement windows succeeded the stone mullioned window, to become the most common window type by the second half of the eighteenth century. The traditional
More informationK17.12 Door closers K17. Doors 01.09.2013
K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor
More informationSection 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
More informationVDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test
More informationSelecting Energy-Efficient Windows
Selecting Energy-Efficient Windows E N E R I N F O A D V I S O R S E R I E S Key Points Improving the energy performance of windows is important, since windows are the least insulated surface of most homes.
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More informationInitial Type Testing Report
Centrum stavebního inženýrství a. s., Praha Centre of Building Construction Engineering, Inc., Prague Accredited Testing Laboratory, Authorised Body, Notified Body, Certification Body workplace Zlín -
More informationSize & Range. for windows & doors. Company
Size & Range for windows & doors A Company B General information windows and doors Sizes This catalogue contains all Airlite s standard sizes for windows and doors. These are the ones that we make every
More informationEN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)
4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
More informationEuropean Technical Assessment ETA-15/0652 of 27/10/2015
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011
More informationIntexma Graphics (Pty) Ltd
Intexma Graphics (Pty) Ltd Distributors for the complete supply of signage materials comprising of single and double roll up stands, banner walls, point of sale tables, signage boards and light boxes.
More informationTOTALLY FRAMELESS GLASS SCREENS AND DOORS ALL-BRITISH BETA MODULAR
TOTALLY GLASS SCREENS AND DOORS Design your own shower screen system for 40mm trays or wetfloors Create a wetroom any size, anywhere BETA MODULAR FRAMELESS 2 Beta Screens and Doors Beta Screens are distinguished
More informationReduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U
Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U Applications The High Density Cabinets are suitable for Central Offices and can be used as fiber nodes and termination points
More informationcomar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites.
Uniclass EPIC L3811:P43 C421:X421 CI/SfB (21 4) Xh4 comar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites. The Parkside Group Ltd Unit 5, The Willow Centre
More informationAstragal: a vertical member placed at the meeting edges of a double door to provide a weather seal and may be used to anchor the fixed door.
Window and Door Dictionary AAMA: American Architectural Manufacturers Association. A national trade association that establishes voluntary standards for the window, door, and skylight industry. Ambient
More informationSun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationCrawford 220 Folding door. Product datasheet
Copyright and Disclaimer Notice Although the contents of this publication have been compiled with the greatest possible care, Crawford cannot accept liability for any damage that might arise from errors
More informationEN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
More informationCERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED
CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.
More informationDESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS
SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough
More informationSeries 456 Commercial Awning Window
Commercial Awning Window COMMERCIAL SERIES Photo courtesy of Hanlon Windows Australia DATE: MAY 2013 REPLACES: MARCH 2008 COMMERCIAL SERIES KEY FEATURES/PERFORMANCE CHARACTERISTICS Scale: not to scale
More informationProfiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa
Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard
More informationSECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
More informationHALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
More informationsliding window & mono-rail Sliding window upvc window profile systems Auf der Breit 2 DE - 76227 Karlsruhe
KunststoffFenstersysteme aluplast Gmb (ead Office) upv window profile systems Auf der reit DE 77 Karlsruhe fon: +9 71 717 fax: +9 71 7171999 info.de@aluplast.net www.aluplast.net aluplast India Pvt. Ltd.
More informationCasement/Awning Window Parts Reference Catalog
Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100
More informationGLAZING RUBBERS. AGS Commercial and Residential Products
GLAZING RUBBERS AGS Commercial and Residential Products We have pleasure in presenting to you the new Capral Glazing Rubber catalogue. This catalogue is designed to simplify the selection and ordering
More informationBYPASS TUB ENCLOSURE... 12 SLIDING DOOR AND FIXED PANEL SLIDING DOOR AND FIXED PANEL WITH RETURN PANEL SLIDING DOOR AND FIXED PANEL
HIGH PRECISION, QUALITY AND PERFORMANCE FEATURES... 2-3 IN-LINE BYPASS... 5-8 BYPASS SLIDING DOORS 2 SIDED BYPASS... 9-11 BYPASS SLIDING DOORS WITH RETURN PANEL BYPASS TUB ENCLOSURE... 12 BYPASS SLIDING
More information2 Axis Solar Tracker / 12 Kw
2 Axis Solar Tracker / 12 Kw 4 Rows 14 metres 4 rows x 14 metres Quantity / Panel Type: 68 units Photovoltaic panel 1.600 x 790 mm Panel power / Total power: 165 W 11,2 Kw Total Surface: 94 m² Diameter
More informationBLOWING DUST INFILTRATION TEST REPORT. Rendered to: TEX-STAR WINDOWS, INC. PROJECT: Blowing Dust Test SERIES: 3000 Double Hung Window
Architectural Testing BLOWING DUST INFILTRATION TEST REPORT Rendered to: TEX-STAR WINDOWS, INC. PROJECT: Blowing Dust Test SERIES: 3000 Double Hung Window Report No: 99462.01-801-44 Test Completion Date:
More informationWINDOW INSTALLATION GUIDE
WINDOW INSTALLATION GUIDE is not responsible for or liable for any use or misuse of the information contained in this window installation guide. Window Installation Guide This guide provides basic information
More informationNarrow stile lock 1314
3 2 4 6 6 1 3 2 4 4 5 3 2 4 3 5.... ( (. ). ) 11 12 5 3 5 4 8 1 6 20 8.5 6.5 19 Backset 15 3 5 2 1 5 2 5 5 0 8 9 2 8 1 1 21-1mm 12 8 24 1 6 8 1 ( 9 2 5 ) ) ). ) Narrow stile lock 1314 CE EN 12209 2 4 5
More informationvinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and
vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? We are confident that we carry a style and size to suit your application. You can be sure that your investment will add value to your home,
More informationSTAIRCASES I DOORS I WINDOWS
ARU JOINERY Timber Processing since 1994 WINDOWS DOORS STAIRCASES WINDOWS We offer timber and alu-clad windows in 3 basic varieties: CASEMENT, TILT & TURN, and SASH windows, with a vast array of design
More informationBASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
More information