Control Monitor CoMo Net
|
|
|
- Harvey Dennis
- 9 years ago
- Views:
Transcription
1 Measure & Analze MM Control Monitor CoMo Net Web Server for Production Monitoring Tpe 5863A Press-fit processes are frequentl used joining techniques. However, subsequent nondestructive testing of these connections can be ver problematic, virtuall making in-process testing a must. CoMo Net is ideal for this purpose, recording the interdependent measurands, e.g. joining force and displacement distance, and evaluating their functional relationship. The evaluation results can then be used to separate nonconforming parts for reprocessing or to divide production into different tolerance classes. Designed as a web server, CoMo Net can be easil integrated into existing Ethernet networks. A web browser running either on an existing visualization unit or on a PC is used for programming and visualizing the current process. The intuitive operating method guides the operator quickl and reliabl through the setup procedure for the measuring process. Flexible monitoring of joining processes and product testing. Connection for piezoelectric and strain gauge sensors as well as sensors with voltage output. Measuring mode (x) or (t) 12 evaluation functions, which can be freel combined, for monitoring threading, curve shape, slope, hsteresis, blocking force and final position. Real-time thresholds for overload protection or for speed control. Monitors up to 20 ccles per second. Fast actuation via digital I/O of SPC Memor for storing the last 10 measured curves for error analsis, reference curve as well as for 16 measuring programs. Extensive process data compilation with statistical cp and cpk value analses. Integral web server. Intuitive setup via Ethernet and standard web browser. Top-hat rail mounting. Options: Profibus DP Description The CoMo Net is a two-channel control monitor for DIN rail mounting for monitoring and classifing industrial processes and operates on a 24V industrial suppl. 6 SPC-compatible digital inputs and outputs allow the sstem to be integrated into a machine control sstem. The CoMo Net can be networked via TCP/IP and Ethernet. The RS 232C interface is used solel for testing and servicing purposes. The sstem is operated exclusivel b means of a standard web browser via Ethernet on a PC or web terminal (parameter setting, visualization). The web server integrated in the CoMo Net controls the HTML pages for operation, with the data server controlling the exchange of process data with the outside world. Access to the various menu levels is controlled for operators, supervisors or service personnel, with authorization being required b password. Measuring Amplifier -channel (e.g. force) Charge amplifier for piezoelectric sensors or voltage amplifiers for piezoresistive sensors, strain gauge bridges or sensors with voltage output. Page 1/9
2 Measuring Amplifier x-channel (e.g. displacement) Voltage amplifier for potentiometric displacement sensor; power suppl through control monitor. Depending on the application selected, the measurands saved are evaluated after the ccle. Profibus DP (extension module) Sstem integration is possible via the Profibus (with a transmission rate up to 12Mbaud), which can be provided as an optional extra. The following functions can be controlled: Measuring ccle, Start/Stop Trigger, Start/Stop Taring x, Parameter set switching Statistics/Trend deleting Quer: Measuring readiness/status Read, process evaluation Read, real-time thresholds x, Calibration The transmission factors of all amplifiers (charge, displacement and strain gauge) are checked within the scope of a function check against the capacitance and voltage references present in the CoMo Net. If these are outside the tolerances specified, the CoMo Net must be calibrated with an external charge or voltage source. All calibration values and other information such as the MAC address are stored in the EEP- ROM on the LVU card. The CoMo Net has CE conformit and complies with EMC standards EN (interference emission, residential areas) and EN (interference immunit, industrial areas). Its interference immunit was tested with the grounding screw fitted. Inputs and outputs are protected with varistors against electrostatic charges. Its degree of protection is IP 20. Intranet or Internet Power Error Measure Network RDTDLink Ethernet 10Base-T LED's 6x WEB-Terminal or PC RS-232C CPU Machine Control Sstem SPS 6x Service Option DP-Slave Profibus DP - Piezoresistive Sensor - Strain Gauge Bridge - Voltage/Current Piezoelectric Sensor Displacement Sensor Charge Amplifier Strain Gauge Amplifier Voltage Amplifier Suppl PLC Y (Force) PC Scaled Monitor Outputs for Start-Up X (Displacement) Fig. 1: Block schematic diagram of CoMo Net Tpe 5863A VDC Page 2/9
3 Process Arrangement PC Browser IPC Browser Web Terminal Browser Kistler Sstem-Komponente Component T C P / I P Hub Hub Factor-LAN Ethernet TCP/IP Data Server Data Server CoMo Net CoMo Net CoMo Net Data Processing Service e.g. qs-stat Web- Server Web- Server Web- Server Data Processing Service SPS Data Protection Other Services Operation Fig. 2: Measurement Fig. 3: Measurement setting Page 3/9
4 Evaluation Functions Up to 12 evaluation functions of varing tpes such as boxes, thresholds, limit positions, gradients d or dx and hsteresis can be activated and freel combined for the purpose of process monitoring. Various information can be displaed for each evaluation element, namel a trend, the distribution of the point of intersection of the curve with the element, or statistics such as the average, standard deviation cp or cpk value. The corresponding process values can be displaed and stored in numerical form. A control signal (conforming/nonconforming) is actuated and then fed to the interfaces (digital outputs, Profibus DP or Ethernet) for process evaluation. Limit Value Monitoring in Real Time: Real-time thresholds can be used to actuate trigger signals or, for example, to monitor safet criteria (e.g. overload protection). Tpe of limit Quantit 2 Post-Ccle Evaluation Functions and Process Values Evaluation function Numeric process values Entr/exit point Minimum/maximum values Point of intersection, x maximum, stop position Gradient d/dx d, dx hsteresis Further thresholds are used to monitor various partial ranges of the signal characteristic. Evaluation takes place after the measuring ccle x 1 / t 1 x 2 / t OK NOK 6 1 Fig. 5: Thresholds for monitoring partial ranges Trigger Alarm "after Ccle" 4 "real-time" "real-time" "real-time" "after Ccle" Boxes The box function is used to monitor whether the signal characteristic enters and exits the prescribed sides of the box. The other sides must not be touched. Fig. 4: Real-time threshold monitoring OK NOK Fig. 6: Monitoring with box functions Page 4/9
5 Boxes Stop Position max - min 7 OK NOK 8 x Fig. 7: Differential monitoring Fig. 10: Monitoring the stop position during press work Hsteresis Monitoring function, e.g. for testing springs Limit Position d OK NOK 1 7 x Fig. 8: Hsteresis Fig. 11: Monitoring the limit position dx 4 Fig. 9: Hsteresis x x Page 5/9
6 Setting Evaluation / Process Analsis Fig. 12: Setting evaluation Fig. 13: Trend Fig. 14: Statistics Fig. 15: Numeric Page 6/9
7 Technical Data Power source for piezoresistive sensor Analog inputs (general data) 2 Sampling frequenc per channel khz 10 Number of measuring points per ccle 250, 500 or 1000 Resolution of analog/digital converter (21 V pp) Bit 12 Charge amplifier for piezoelectric sensor (BNC) Measuring range pc ± (divided into 4 decade partial ranges) Error with calibration % <1 without calibration % <3 Repeat error %FS <0,1 Zero point error and zero transition (Reset/Operate) SW correction Switching times Reset/Operate ms <5 Operate/Reset (residual charge <0,5 % FS) ms <15 Drift at 25 C pc/s <0,1 at 50 C pc/s <0,5 Force voltage amplifier for sensors with voltage output (instead of charge amplifier) Sensor tpes: Piezoresistive (current fed) Strain gauge bridge (voltage-fed, 4 or 6 conductor) Sensor with voltage or current output Measuring range V ±0,005 ±10 Range subdivision Range 1 V ±0,005 ±0,05 Range 2 V ±0,05 ±0,5 Range 3 V ±0,1 ±1,0 Range 4 V ±1,0 ±10 Common mode of the differential input stage V ±18 Input filter, passive khz 5 Error Range ±0,005 ±0,05 V % <1,5 Range ±0,05 ±10 V % <1 max. input voltage (continuous) V ±20 Taring function (voltage feed after differential stage) Voltage source (2 ranges), Resolution V ±1, ±0,1 (0,05 %) Zero offset in relation to ±10 V Output Scaling amplifier 1 10 V ±1 ±10 Scaling amplifier > V ±1 ±10 Suppl voltage between +Ex (10 V) and I Ref Output current ma 4 Error % <0,5 Load resistance kω <4,7 Power source for strain gauge bridge Output voltage V 5 or 10 Error % <0,5 Output current ma <40 Remarks - The effective bridge voltage is measured and the result taken into account b the software (this is important for 6-conductor connections). - Shunt calibration with selectable external resistance. - The sum of the currents for the strain gauge bridge suppl and the potentiometric displacement sensor must not exceed 60 ma because of the equipment power dissipation. Voltage amplifier for potentiometric displacement sensor Measuring range V ±0,5 ±10 Error % <1 Zero offset of the input signal, resolution V ±10 (±0,02) Power sources for displacement sensor suppl 2 Output voltage V 10/+10 Error % <0,2 Output current ma <20 Analog monitor outputs 2 (2 mm sockets, general data) Output current ma <3 Error (without error, measuring amplifier) % 0,5 Monitor output (Force) Output voltage for FS input signal V ±10 Zero offset mv <±10 Zero transition (Reset / Operate) pc <±0,5 Monitor output X (displacement corrected) Output voltage for FS input signal V Zero offset mv <±20 Digital inputs (optocoupler, electricall isolated) 6 Functions: 1 ccle, 4 parameter sets, 1 reserve Bounce-masking b software Logical input level, High V >14 Logical input level, Low V <8 Input current at 24 V ma 5 Page 7/9
8 Digital outputs 6 (Photo MOS rela, electricall isolated, common feedback) Functions: 1 Read, 5 evaluation elements Current loading, continuous ma <100 Current loading, pulse <0,1 s ma <300 Resistance when switched on Ω <50 (tp. 30) Voltage V <40 Interface Ethernet 10Base-T (electricall isolated) Transmission rate Mbps 10 Topolog Twisted Pairs 2 LED displas for Receiver/Transmitter (RxD/TxD) and Link 2 Interface RS-232C (No control leads, level according to standard, electricall isolated) Baud rates Data format 8 data bits, 1 stop bit, no parit Profibus-DP Transmission of all control functions and process data. Measuring curves can also be transmitted with the later expansion DP-V1). Interface Tpe RS-485A Connector Tpe DSUB-9S Max. transmission rate MBaud 12 Line termination Selectable Connections Charge input for piezoelectric sensor Tpe BNC neg. Force voltage amplifier Tpe Phoenix 3,5 mm for sensors with voltage output (piezoresistive sensor, strain gauge bridge or other) Monitor output Tpe Phoenix 3,5 mm Monitor outputs x = displacement corrected Tpe 2 mm test socket = force (charge amplifier or strain gauge) Digital outputs, qt. 6 Tpe Phoenix 3,5 mm Digital inputs, qt. 6 Tpe Phoenix 3,5 mm Equipment suppl Tpe Phoenix 3,5 mm Interface Ethernet 10Base-T Tpe RJ45 Remarks - The recommendations in the operating instructions concerning EMC must be observed. - For applications subject to EMC, the electricall isolated measuring circuit can be snugl connected to the case (protective ground). using the cheese-head screw M2,5 x 5 under the input BNC. General Evaluation time (according to the number of functions) ms ca. 10 <500 Parameter sets 16 Displa for WEB terminal SVGA (800x600) Operating temperature range C 0 50 Power suppl VDC W ca. 6 Voltage between suppl connections and case V rms <40 Case for DIN rail mounting,, Dimensions (WxHxD) mm 40x150x127 Weight kg 0,8 Page 8/9
9 Accessories Included Tpe onl for Tpe 5863A10 and 5863A11 Test cable for monitor outputs, mm sockets, red Test cable for monitor outputs, mm sockets, black Ethernet cable, crossed, categor 5 STP, xRJ45, 3 m Optional Accessories Tpe RS-232C cable, null modem, 1200A27 DSUB-9P/DSUB-9S, 5 m Simulator for feeding in force/displacement Z15822 signals Cable to simulator Z15822 Z Z Ordering Ke for the CoMo Net Control Monitor Tpe 5863A CoMo Net, network link via Ethernet 10 Mbit/s interface, 10 RJ45 connection, 2-channel amplifier, measuring channel for charge, voltage and strain gauges, x measuring channel for voltage and potentiometric unit EM-1 expansion module Profibus DP interface 01 CoMo Net, network link via Ethernet 10 Mbit/s interface, 11 RJ45 connection, 2-channel amplifier, measuring channel for charge, voltage and strain gauges, x measuring channel for voltage and potentiometric unit with mounted EM-1 expansion module Profibus DP interface Fig. 16: Tp 5863A11 Fig. 17: Tp 5863A01 Fig. 18: 5863A10 Fig. 19: Tp 5863A Page 9/9
9310 EN. Press-fit, Jointing and Clinching Monitor DIGIFORCE. Series 9310
Press-fit, Jointing and Clinching Monitor DIGIFORCE Series 9310 Code: Delivery: Warranty: ex stock 24 months Desktop/panel version Ethernet Cabinet Module Especially economical press-fit and process monitoring
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Differential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
Vibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
Set for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES
ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS Enhanced defect detection Built-in diagnostics for press machinery Quicker setup and easier maintenance than competitive systems Lowest monitoring cost per
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en
MP85 / MP85DP Data sheet MP85 MP85DP Special features - 100% quality control of the production process - Universal twin-channel amplifier for many of the usual market sensors - Powerful algorithms for
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Reaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English
xepi 2 Diagnostic Unit and Configuration Interface Doc. Version 4.0 Installation Guide English Dear Customer, This "Installation Guide" will help you to install the hardware. If you have any further questions,
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8
Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment
USB-AD14f Data Acquisition System (USB)
Data Acquisition System (USB) Measurement & Control. Super-Low Priced. Record and output signals with the USB-AD14f. The USB data acquisition system accomodated in a stable aluminum housing is ideal for
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
ABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
USB-AD16f Data acquisition system (USB)
Data acquisition system (USB) Measurement & Control. Extremely powerful. Precisely record and output signals with the USB-AD16f: The high-performance USB data acquisition system accomodated in a stable
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.
PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Controlers. Controler
s 4 INDEX Controlers Color Wheel LED Remote page 4 Push Button RGB Controler page 5 Dimmable LED Power Supplies page 6 DMX Controler Sunlite STICK 2 page 7 DMX Controler Sunlite STICK-GA2 page 8 DMX Controler
CANtrol EC Modular Control System Powerful and versatile
Controls CANtrol EC Modular Control System Powerful and versatile CANtrol EC The modular control system Components of CANtrol EC 1 EC1000 Ethernet Controller 2 E-I/O EtherCAT I/O family communicating controlling
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
3-Component Measuring System
Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
The Universal DAQ Device. Connect and measure immediately!
The Universal DAQ Device. Connect and measure immediately! XXL performance in mini format 8 universal connectors 1) on each QuantumX device suited for most common transducer technologies: 1) See technical
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
MechoNet TM Network Interface (MNI) Specification Submittal
MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
Physical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973
Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
Terminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Complete Installation Guide Product Description Product Features SJ-L-DSL is network signal extension device, which consists of remote unit and local unit. It can
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP
Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
PPM Users Manual Signature Software 01-12-00
PPM Users Manual Signature Software 0-2-00 PPM User Manual /8/02 Software Versions: 0.0.27 Contents. Introduction 2 2. Parameters 3 2. Overload Limit...4 2.2 Relative Upper Limit...4 2.3 Relative Lower
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Fieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO