ROOFING ACCESSORIES GENERAL References. England and Wales
|
|
|
- Vivien Russell
- 10 years ago
- Views:
Transcription
1 CI/SfB (47) Uniclass L529 October 2014 GENERAL References England and Wales Building Regulations 2010 Approved Document C amd & 2013 'Resistance to moisture' Approved Document F 'Means of ventilation' Approved Document H 2010 'Drainage and waste disposal' Scotland The Building (Scotland) Regulations 2004 Technical Handbook Domestic Buildings Section 'Control of condensation in roofs' Northern Ireland Building Regulations (Northern Ireland) 2012 Technical Booklet C 'Site preparation and resistance to moisture'. Section 7 'Roofs' Republic of Ireland Building Regulations 2012 Technical Guidance Document F 'Ventilation' Section 2 'Condensation in roofs' Code of practice BS 5250: 2011 'Code of practice for control of condensation in buildings' Other documents BS 5534: 2014 'Slating and tiling for pitched roofs and vertical cladding - Code of practice' BS : 2013 'Workmanship on building sites. Code of practice for slating and tiling of roofs and cladding' BRE Report BR 262: 2002 'Thermal insulation - avoiding risks' BRE Digest 'Reducing the risk of pest infestations in buildings' BRE IP 5/06 Modelling condensation and airflow in pitched roofs Robust Details: 'Limiting thermal bridging and air leakage: Robust construction details for dwellings and similar buildings' 2001, DEFRA and DTLR, The Stationery Office 'Thermal and moisture performance of pitched roofs' PiI project report 2005 s Specimen clauses are given on product pages. Most clauses require choices to be made. For Protect roofing accessory products, add the following to every specification: All roofing accessories to be obtained from Protect Membranes Limited, 2 Brooklands Road, Sale, Cheshire M33 3SS. Tel: , Fax: , [email protected] For performance specifications, product names and references may be omitted. Technical advice Advice is available from our Technical Department on all aspects of roofing underlays, roofing accessories and design. Contact [email protected]. Other products Protect Buildtight TM Airtightness range Protect construction membranes, including reflective technology Protect VC Foil vapour control layer Protect F1 floor protection membrane Supply Protect Membranes products are available through stockists nationally. Glidevale White Papers 'The new roof ventilation provisions explained' 2006 'Well sealed ceilings explained' PROTECT MEMBRANES LIMITED 2 Brooklands Road, Sale, Cheshire M33 3SS Tel: Fax: [email protected] Web: Protect Membranes Limited maintains a policy of continuous development and reserves the right to amend product specifications without notice. A division of Building Product Design Ltd. Company Registration No:
2 FULMETAL REDIROLL VENTILATED DRY RIDGE/HIP PROTECT SOLUTIONS Protect accessories for tile and slate roofs provide a range of solutions which offer better performance than the traditional alternatives. Easier to install. More dependable. Reliably maintain the weatherproof function of the roof covering. THE PRODUCT RANGE Fulmetal Rediroll Ventilated Dry Ridge/Hip is used with conventional ridge and hip tiles to provide both ventilation and weather protection. AluFlash Lightweight Flashing is an environmentally-friendly alternative to lead; very lightweight and easy to form without specialist skills or tools. Universal Dry Verge system for interlocking tiles; avoids the problems of mortar verges, being easily dry-fixed, resistant to wind uplift and not subject to cracking. DV Slate Dry Verge system for natural and artificial slates; offers the same advantages as Universal Dry Verge. Universal Dry Fix Valley Trough provides a flush appearance with free drainage; dry-fixed with all tiles and slates. Univalley 125 Valley Trough provides an open valley for clear drainage; dry-fixed with slates or mortar bedded with tiles. Universal Bonding Strip provides weather protection at the junction between roofs on semi-detached or terraced houses, especially when re-roofing with different materials. page Description Protect Fulmetal Rediroll is an innovative universal dry-fixed ventilated ridge and hip system. Manufactured from aluminium, the Fulmetal Rediroll overcomes the durability and weathering problems associated with fabric-based systems. Applications A universal solution suitable for all ridge and hip tiles and all roof tiles and slates. Can be used to provide a ventilation area equivalent to 5000mm 2 /m. Can be used to comply with roof space ventilation requirements of Building Regulations Approved Document C2 and BS Provides ventilation between ridge tiles even on flat roof tiles and slates. All-aluminium construction is rot-proof. Ventilated, but driving rain resistant. Unique weatherproof design avoids the need for ridge unions. Unique stainless steel clip system provides mechanical fixing of the ridge tiles and correct spacing to ensure an even appearance. Screw sleeve to prevent light bleed between ridges (if required). Handy 6m pack contains all components needed to install the system. Design life in excess of 30 years. Optional hip tile carrier also available. Size 300mm wide. Mechanically-fixed ventilated ridge and hip. Provide mechanical fixing of ridge and hip tiles to BS 5534 together with high level roof ventilation by means of Protect Fulmetal Rediroll. Fixing system to suit any tile type on both ridges and hips. Install continuously to provide ventilation area equivalent to 5000mm 2 /m* to comply with Building Regulations Approved Document C amd & 2013 and BS 5250: Fix in *For plain wing angle ridges please consult Protect Technical Services. ensures efficient water discharge into the gutter; avoids sagging and ponding and will not rot. 10 Appearance Colours: terracotta or grey to suit roof covering. G6 Solar Inlet terminal provides a reliable means of maintaining the integrity of the roof covering where cables or pipes pass through it, for example to provide connections for solar heating or photovoltaic panels. 11 Fulmetal Rediroll with half round ridge and pantiles Ridge tile (not part of system) passivated heavy duty steel screw Fulmetal Rediroll
3 ALUFLASH LIGHTWEIGHT FLASHING UNIVERSAL DRY VERGE SYSTEM AluFlash is a revolutionary and environmentally-friendly alternative to lead as a weathering flashing material for buildings. It incorporates all the useful features of lead but eliminates those that are undesirable. It is aluminium-based and available in two unique surface finishes depending on the application. Lightweight, easy and safe to handle. Minimum 30 year design life. Easy to form over a range of roof profiles without the need for specialist skills or tools. Both elements of AluFlash have been durability tested and have been used in Europe for over 10 years as flashing materials. Non-toxic. No potential hazards for installers and no contamination of run-off water. Environmentally friendly. Suitable for rainwater harvesting systems. 6% of the weight of code 4 lead, providing health and safety benefits for installers. AA fire rating, enabling unrestricted use. Integral self-adhesive backing eliminates the risk of wind uplift which might allow water penetration. Recyclable backing sheet to keep adhesive clean until final installation. Highly durable surface finish which does not oxidise, stain or require patination oil. BM TRADA Certified, certificate number CPS-015. Finishes Colour: lead grey or terracotta. Cross-corrugated finish* Designed for use where the flashing has to be moulded over and around complex shapes such as profiled roof tiles and corner junctions. The unique cross-corrugation pattern allows the AluFlash to curve and bend in more than one direction at once. * patent applied for Embossed finish Designed for applications requiring less complex shaping such as pitched roof valleys, secret gutters, soakers for slates and double-lap tiles, and box gutters. Flashings to be AluFlash solvent lacquer-coated aluminium sheet with adhesive butyl backing. Finish: embossed / crosscorrugated. AluFlash supplied by Protect Membranes Ltd., 2 Brooklands Road, Sale, Cheshire, M33 3SS. Telephone: , Fax: [email protected] The Protect universal dry verge system is compatible with all interlocking metric sized roof tiles and designed to overcome the problems of traditional mortar bedding, such as cracking and long term maintenance. Its unique ambidextrous patented fixing mechanism locks the units in place whilst allowing lateral and vertical adjustment to accommodate differing tile profiles. Truly universal, the units are ambidextrous for either left or right verges offering significant advantages for ordering and stockholding purposes. Components Universal Verge Unit, right or left hand Provides full wind uplift and weather protection. Mechanically fixed, no maintenance required. Quick and easy to fix, no special skills or tools required. All weather fixing, no adhesive or sealants required. Compatible with all interlocking metric sized roof tiles at batten gauges from 315mm to 343mm. Compatible with all mortar or dry fixed ridge systems. Available in Black, Brown or Grey. Retains the traditional stepped appearance of the roof tiles. Meets the requirements of BS 5534 for mechanical fixing. Complies with NHBC standards for pitched roofs. Designed and developed under ISO 9001 Quality Management Systems. UV and heat resistant. Prevents entry of birds and large insects. Unaffected by differential movement or settlement. Can be used to comply with Building Regulations. Composition, Manufacture Units, Ridge end caps and Eaves closure injection moulded polypropylene. Install Protect Universal Dry Verge System at roof verges to provide continuous cover over batten ends and tiles to protect against wind uplift and driving rain. System to include ambidextrous right or left hand units and ridge end caps in injection moulded UV stabilised polypropylene and Eaves Closure in injection moulded polypropylene to exclude birds and large insects. Fix mechanically in CPS-015 Material AluFlash is a combination of highly durable aluminium sheet with a solvent lacquer upper surface and an adhesive butyl backing with high levels of tack to prevent wind uplift. 4 Sizes Roll length: 5m. Roll widths: 150, 200, 250, 300, 350, 400, 450, 500, and 600mm. Thickness: 4.1mm (cross-corrugated), 0.65mm (embossed) Half Round Ridge Cap Angled Ridge Cap
4 DV SLATE DRY VERGE SYSTEM UNIVERSAL DRY FIX VALLEY TROUGH The Protect DV Slate Dry Verge system is mechanically fixed, and once installed provides complete and continuous cover over batten ends and slates, protecting the verge from wind uplift and driving rain. For use with natural and artificial double-lap slates not exceeding 5mm thickness, including Redland Cambrian and Marley Monarch. The system is designed to overcome the problems of traditional mortar bedded verges, which may crack due to differential movement. Mortar will also crack and erode due to weathering and eventually fall away, leaving vulnerable slate edges exposed. Roof verges are subject to high level wind uplift and this will lead to loosening of slates and eventual failure. Can be used to comply with Building Regulations Approved Document C and BS Provides full wind uplift and water protection. Self draining: any rainwater which enters the system is carried away from the roof covering and directly into the gutter. Modular construction: a single verge extrusion, plus unobtrusive connector units and handed eaves stop ends, which prevent ingress of birds. Quick fixing: completely dry-fixed and can be installed in any weather. No adhesive, sealant or special tools are required. The verge is fitted before laying the slates. Requires no maintenance once installed. Allows for thermal movement: all fixing holes are slotted, and connector units and ridge end caps include gaskets which allow movement. Install Protect DV Slate Dry Verge system at roof verges to provide continuous cover over batten ends and slates to protect against wind uplift and driving rain. System to include extruded PVC-U edge sections, preformed gasket-sealed ridge end caps, and eaves stop ends to exclude birds. Fix mechanically in Protect has introduced an innovative second generation Universal GRP Dry Fix Valley Trough, adding to the extensive range of Protect Dry Fix solutions. Dry fixing is quicker, less dependent on site skills and guarantees a neater finish than mortar bedding. Universal - accommodates roof pitches from 17.5º and above, and compatible with flat or profiled tiles and slates, providing a flush appearance. One size 3m. Traditionally popular length for speedy installation, readily cut on site. Positive fix to valley batten. Substantial 25mm vertical weather check which also provides strong fast fix to valley batten. Unique shape assists with free drainage with secure protection against water ingress. Non-toxic and environmentally friendly. No potential hazards for installers and no contamination of run-off water. Suitable for rainwater harvesting systems. No resale value to a prospective thief. Integral Gel coat. Proven to provide increased durability. Fire resistant. Designated AB fire rating to BS 476: Part 3: Does not streak or stain tiles. Material and composition Universal Dry Fix Valley Trough is manufactured from 1mm thick GRP in 3m lengths. Appearance Colour: Lead Grey. Install Protect Universal Dry Fix Valley Trough at roof valleys. Valley Trough to be GRP with gel coat finish, with central weather bar to assist free drainage with secure protection against water ingress. AB fire rating to BS 476: Part 3: Mechanically fix in DV204 Ridge end caps Incorporating a gasket seal, and supplied with fixing bracket. For fibre cement ridge tiles only. Composition, Manufacture Extruded PVC-U in 2.4m long sections. Ridge and end caps are vacuum-formed ABS. Connectors and stop ends are injection-moulded polypropylene. All components are matt slate grey. DV201 Connector unit DV200 Dry Verge section length 2440mm Plain tiles or slates Universal Dry Fix Valley Trough Half-round, for roof pitches from to 45 Eaves stop end DV202 right hand DV203 left hand underlay rafter batten 200 x 12mm support board Plain angle, for dedicated roof pitches of , 25, 30, 35, , 45 Dry Verge installation 25mm maximum batten overhang Profiled tiles Universal Dry Fix Valley Trough nogging DV200 Dry Verge section Slates Concrete or clay block end ridges available from most tile manufacturers can also be used to finish the gable end. Protect VP400 Plus LR roofing underlay
5 UNIVALLEY 125 VALLEY TROUGH UNIVERSAL BONDING STRIP A valley is one of the most vulnerable parts of the roof - the Protect Univalley 125 GRP Valley Trough provides a universal solution for valley detailing offering advantages of economy and performance over valley tiles, concrete troughs and lead valleys. The Protect Univalley 125 incorporates many design features and has been developed as a universal product for ease of installation, simplified stockholding and minimum wastage. resin-bonded mortar grip water slew prevention bar mortar retention check Tests undertaken by Brunel University, Uxbridge, show that a clear water channel of 125mm is necessary for roof drainage areas greater than 25 square metres. Compatible with either slates or tiles the Univalley 125 has a 125mm clear water channel to ensure optimum performance and incorporates a gel coat, proven to provide increased durability. Application showing both slate and tile Universal for slate or tile. Can be dry fixed with all slates including Redland Cambrian and Marley Monarch or wet bedded with all concrete and clay roof tiles. One size 3 metres. Traditionally popular length for speed of installation, with universal width. Readily cut on site. Integral mortar retention check. Holds green mortar preventing slippage into open valley during fixing. Provides secondary weather bar against rain penetration. Positive fix to valley batten. Substantial 25mm vertical weather check which also provides strong fast fix to valley batten. Resin bonded wide mortar grips. Ensures maximum adhesion for mortar. Deep valley section and shape. Secure protection against water ingress. Meets LSA and Brunel University requirements. Integral water slew prevention bar. Tested to enhance water discharge allowing use with dissimilar roof pitches up to 15 degrees difference. Integral Gel coat. Proven to provide increased durability. Fire Resistant. Designated AB rating to BS 476: Part 3: Install Protect Univalley 125 Valley Trough at roof valleys. Valley trough to be GRP with gel coat finish, provide 125mm wide clear water channel, and incorporate water slew prevention bar, water checks, mortar retention check and resin bonded mortar grips. Fix in 75mm gutter channel with 20mm upstand Universal Bonding Strip Existing roof - slates existing underlay resin-bonded mortar grip secondary 10mm storm bars The Protect Universal GRP Bonding Strip provides even greater protection at the junction between old and new roofing on semi-detached or terraced properties. The design incorporates many features to provide an effective and economical solution to the problem of weathering the junction at party walls when properties are re-roofed at different times with incompatible materials. Universal design. Can be fitted with any combination of double lap or interlocking slates, clay and concrete tiles. Design ensures slates don t kick up. Improves weather resistance. Enhances appearance of roof. Secret or open gutter for efficient discharge of water. Unobtrusive for sheltered locations. Open gutter Positive gutter size (meets LSA requirements). 75mm wide gutter channel with 20mm upstands. Ensures swift discharge of rainwater. Independent mortar fixing positions. Resin bonded for maximum adhesion. Allows for differential movement between dissimilar roof materials. Design prevents battens being carried over division wall. Meets the requirement of BS 8000 (workmanship) for firebreak walls. Secondary 10mm storm bars. Enhanced weatherability. Integral mortar retention. Holds green mortar preventing slippage into open gutter during fixing. Integral Gel coat. Proven to provide increased durability. Dry fix option. Slates can be dry fixed without the risk of water penetration. One size 3 metres. Lightweight, easy to handle, readily cut on site. Fire Resistant. Designated AB rating to BS 476: Part 3: Can be used in a fire separation wall detail. Install Protect Universal Bonding Strip at junction between old and new roofing. Bonding strip to be GRP with gel coat finish, and to incorporate a gutter channel 75mm wide with 20mm upstands, 10mm secondary storm bars, and mortar channels with resin bonded mortar grips. Fix in accordance with New roof - tiles mortar bedding onto resin-bonded grip tiling battens cut back to provide fire break Univalley 125 trough 125mm clear water channel rafter slates tile batten valley batten tiles Protect A1 roofing underlay mortar bedding onto resin-bonded grip support board party wall Universal Bonding Strip Secret gutter nogging rafter
6 OFV EAVES SKIRT G6 SOLAR INLET TERMINAL The Protect replaces both the underlay into the gutter and the traditional tilting fillet. It is designed to avoid sagging and ponding of the underlay behind the fascia and ensure correct water discharge into the gutter. Avoids sagging and ponding and will not rot in the gutter unlike bitumen derivatives. Robust 1.5mm PVC-U construction resists impact and UV degradation over time. Prevents wind noise under load. For use with Glidevale 10mm or 25mm over fascia ventilators or directly onto fascia board. Flexible design allows access to the fascia board for fitting gutter brackets. Supplied in 1.5m lengths, 10 lengths per pack. Suitable for new build or refurbishment applications. Can be used to comply with Building Regulations Approved Document C and BS Install Protect eaves skirt to avoid sagging and ponding of underlay behind fascia and ensure correct water discharge into the gutter. Eaves skirt to be extruded in UV-stabilised PVC-U to provide a long term durable solution. Roofing underlay FV100 Over Fascia Ventilator Fascia The Protect G6 Solar Inlet Terminal has been designed to guarantee the integrity of the roof when cables and pipes are routed through the tiles/slates and roofing membrane. Ideal for solar panel installations. Versatile suits virtually all single lap interlocking roof tiles*. G6 also available for slates (soaker base plate) and plain tiles. Specific profiles available to order. Easy installation. Allows user defined holes to be drilled to accommodate different cable/pipe diameters. Five colours available: red, brown, grey, terracotta and red streak. Supplied with Underlay Opening Protector. AA fire rating to BS 476: Part 3: 2004 Low profile cowl for installation under retro fit photovoltaic panels. Compressible foam filler ensures driving and deluge rain resistance. Designed and developed under BS EN ISO9001. Install Protect G6 (versatile/slate soaker/ plain tile, delete as appropriate) inlet as part of the roof covering to provide weather protected inlet[s] for cables or pipes as required. Fix in *Not suitable for use with Plain Tiles, Clay Single Pantiles, Forticrete Centurion Tiles, Goxhill Gaelic Tiles or Interlocking Slates. G6 for slates Continuous Rafter Roll Low profile cowl Continuous Rafter Roll FV250 Over Fascia Ventilator Batten bearers provide positive stop against batten Compressible foam filler provides driving and deluge rain resistance at junction with adjacent tiles Fascia Gutter bracket Fascia Nail fixing point Integral AluFlash flashing ensures positive and permanent weathering Illustration shows G6 inlet for a tiled roof. Slate roof version has no need of foam filler or AluFlash. Anti-capillary bars enhance driving and deluge rain resistance
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
Ubiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter
REDLAND DRY BONDING GUTTER Installation Instructions for Redland Dry Bonding Gutter 1 Introduction 1.1 TECHNICAL DATA Dimensions: 3 m long x 210 mm wide Material: Glass-fibre/polyester composite. Pitch
Including. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
Cupa Natural Slate Roofing design and fixing guide
Cupa Natural Slate Roofing design and fixing guide Cupa Natural Slate synonymous with quality Currently the Spanish slate industry is the undisputed market leader in natural slate production, with 90%
CI/SfB (Ff3) January 2011. Roofing design guide. Showing you the way. Redefining traditional products
CI/SfB (Ff3) January 2011 Roofing design guide Showing you the way Redefining traditional products Contents 2-3 General information Eaves detailing 4 Traditional eave 4 Hardrow slates eave Verge detailing
When considering Roof drainage design the following should be taken into account:
Roof Drainage Design The primary objective of a gutter or spouting system is to remove water from the roof catchment area and channel that water to the ground drainage. Water ingress can have detrimental
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
Roofers Guide to Underslating Membranes
Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Bituminous Sheet Flat Roofs: Their repair and maintenance
Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and
Glidevale offers a complete range
CI/SfB (13.9) Uniclass Ss_32_20_30_48 June 2016 Glidevale offers a complete range of protection for ground floors against both damp and gases from the ground. This double function avoids the need for a
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
The formation of roof waterproofing details calls for
3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
UBBINK SOLAR IN-ROOF SYSTEM
UBBINK SOLAR IN-ROOF SYSTEM The integrated solar mounting system Installation guide UBBINK SOLAR IN-ROOF SYSTEM Table of contents Solar In-Roof System introduction System components Installation guide
Colorcoat Urban The choice you ll be glad you made. CI/SIB (4-) Nh2 March 2012
Colorcoat Urban The choice you ll be glad you made CI/SIB (4-) Nh2 March 2012 WHY CHOOSE COLORCOAT URBAN? The choice you ll be glad you made. Product benefits: Tata Steel understands that truly sustainable
BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
CHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
THE REDLAND GUIDE TO BS 5534
THE REDLAND GUIDE TO BS 5534 HELPING YOUR COMPANY TO GET ONE STEP AHEAD www.redland.co.uk Enforcement is via authorities such as the National House Building Council (NHBC) and Local Authority Building
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture
Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
Under Tile and Slate Undersheeting System
CI Sf (4-) Nn2 Under Tile and Slate Undersheeting System One system providing a weatherproof barrier, ventilation and insulation A RITISH OARD OF AGREMENT CERTIFICATE NO. 94 / 3055 2 Under Roofing System
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
Upstand Rooflight Natural Light Translucent Upstand Systems
Insulated Panels CI/SfB (4-) Rh2 October 2008 ROOFLIGHT SYSTEM Upstand Rooflight Natural Light Translucent Upstand Systems Upstand Rooflight Pre-assembled Rooflight System Introduction The Upstand Rooflight
DENSO WATERPROOFING SYSTEMS
DENSO WATERPROOFING SYSTEMS Approved Quality Management System AS/NZS ISO 9001:2008 Lloyds Register Certificate N o Mel 0927759 Denso (Australia) Pty Ltd A MEMBER OF WINN & COALES INTERNATIONAL 411 413
I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (47) Ln6 Sixth Issue March 2011 BREATHABLE MEMBRANE FOR UNVENTILATED PITCHED ROOFS AND TIMBER FRAME WALLS Waterproof can be used as a temporary roof covering Non tenting Airtight
FUNCTIONAL REQUIREMENTS
FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 7.9 ROOF COVERINGS TRADITIONAL SLATE AND TILES Workmanship i. All workmanship must be within the tolerances defined in Chapter 1 of this Manual. ii. All
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri
Determination 2009/103 The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri 1. The matters to be determined 1.1 This is a determination under Part 3 Subpart 1 of the
Conservatory roof system designed without compromise - tested to the highest standards
Conservatory roof system designed without compromise - tested to the highest standards The UK s number 1 conservatory roof [email protected] www.synseal.com Your success with Looking for a conservatory
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
CI/SfB (4-) Rf9 January 2016. Dry fix and ventilation systems including UNIVERSAL accessories. Roofing product catalogue 45
CI/SfB (4-) Rf9 January 2016 Dry fix and ventilation systems including UNIVERSAL accessories Roofing product catalogue 45 Today s roofs need to be weatherproof and look good, as well as providing adequate
PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET
CI/SfB (49) Mh8 Midland Lead Manufacturers Ltd Kiln Way Woodville Swadlincote Derbyshire DE11 8ED Tel: 01283 224555 Fax: 01283 550284 e-mail: [email protected] website: www.midlandlead.co.uk Agrément
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd
CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed
Technology at its best. Benefits
Protecting what s under your roof from the elements is simplicity itself with Ruberoid Roofing Shingles. Roofing Shingles make ideal roofing; they are attractive, easy to install and are perfect for use
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
ROOFING. Introduction
1 Introduction The lifetime of a building begins with the choice of materials and for hundreds of years, architects and designers have been inspired by the natural beauty of slate. Through its aesthetic
Epdm Flat Roofing Systems
Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
How To Build A Gambrel Roof And A Gable End Roof
Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,
KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST
KAHU DETAIL LIST 00 / 24 COVER SHEET 01 / 24 ROOF RIDGE 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH
Issue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
Ridge. Hip. Abutment. Eaves. Roof slope. Vertical slating. Clay plain tiles. Valley. Ridge Roll. Verge. Bedded verge.
Verge Vertical tiling Ridge Mono-ridge Clay interlocking Hip Close mitred hip Roof slope Abutment Interlocking tiles Eaves Valley Bedded verge Ridge Roll Rigid sarking Tile vent terminal Fibre cement slates
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors
W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling
Rooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
Installation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.
MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)
Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161 865 4444 Fax: 0161 866 9859 e-mail: [email protected] website: www.icopal.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
FireSmart IRS Insulating Roof Screed
Insulating Roof Screed CI/SfB January 2004 CI/SfB January 2004 M2 P M2 P Icopal Ltd Barton Dock Road Stretford, Manchester M32 0YL Telephone: 0161 865 4444 Fax: 0161 866 9859 Technical Fax: 0161 865 8433
12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
VM ZINC : standing seam Guidelines for specification and installation
VM ZINC : standing seam Guidelines for specification and installation Junglim Architecture - QUARTZ-ZINC Roofing and cladding system in VM ZINC Roofs from a 3 pitch and facades Freedom with shape and appearance
Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012
Part 7 Roofs Chapter Effective from 1 January 2012 CONTENTS SCOPE DESIGN Clause Page Design standards D1 1 Statutory requirements D2 1 Loadbearing structure D3-D4 1 Trussed rafter roofs D5 1 Traditional
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
V-joint fascia soffit systems
V-joint fascia systems CI/SfB October 2005 (4-) Uniclass L5294 extruded aluminium system with complete versatility for eaves and other building features Bailey V-Joint and fascia system has been designed
Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
Good Craftsmanship Guide. Carpentry and Joinery- Carcassing
Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance
SOLAR-LINE. Roof accessories for solar systems. Your expert for photovoltaic and solar thermal systems
SOLAR-LINE Roof accessories for solar systems Your expert for photovoltaic and solar thermal systems Roof expertise for solar energy systems Your expert for photovoltaic and solar thermal system accessories
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Decra. Decra Roof Systems The first name in lightweight roofing. year guarantee
Decra Decra Roof Systems The first name in lightweight roofing 40 year guarantee Lightweight Fast installation Weather protection Low maintenance 40 year guarantee Decra Roof Systems Lightweight tiles
USER GUIDE Easier, Safer, Betta! www.gripsetbetta.com WATERPROOFING
USER GUIDE Easier, Safer, Betta! www.gripsetbetta.com WATERPROOFING Welcome to Gripset Betta, Over the past 3 decades through the tireless commitment to improve and enhance the way buildings are waterproofed,
STANDING SEAM SHEET METAL ROOFING
STANDING SEAM SHEET METAL ROOFING GENERAL INFORMATION 1.1 For all standing seam metal roofing work consult Columbia University Facilities Exteriors and Historic Preservation group. 1.2 Fabricator is responsible
ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-900* Reissued March, 20 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS
Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 0DH Tel: 01473 257671 Fax 01473 230761 e-mail: [email protected] website: www.bauder.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS
What makes DECRA Roofing Systems unique?
Commercial Roofing As the pioneer of stone coated steel technology, Roofing Systems have been proven around the world since 1957. Marketed and installed in over 120 countries, there are over 1 million
BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS
CI/SfB (57) Uniclass L753 October 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS... PRODUCT RANGE AND OVERVIEW..................................................................................
1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE
1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic
INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group
INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems
The Butler MR-24 Standing Seam Roof Difference A comparison between metal roof systems Roof Systems Necessities Weathertight (don t leak!) Low maintenance Weathertightness Roof clips, seams, panel alignment
Management Consultancy Training. Asbestos Materials. Residential Guide
Asbestos Materials Residential Guide This guide highlights some of the more common asbestos containing materials (ACMs) in low occupancy residential buildings, their uses and likely locations. The guide
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
Introduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs. www.tyvek.co.uk www.construction.tyvek.com
PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs www.tyvek.co.uk www.construction.tyvek.com DuPont TM membranes Providing protection Contents Page Introduction............................................................................................................................
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
Commercial Roof Inspection Form
Inspection Date: Inspector: Building Information Building ID: No.: Used For: Year Roof Applied: Building Description: Permanent Temporary Building Type: Retail Industrial Residential Building Name: Building
