Load Centers and Circuit Breakers. Section 1.

Size: px
Start display at page:

Download "Load Centers and Circuit Breakers. Section 1. www.geindustrial.com"

Transcription

1 Load enters and ircuit reakers Q-Line ircuit reakers Features and enefits PowerMark Gold Load enters Features and enefits PowerMark Gold and Plus Load enters Number Guides Q-Line Plug-in ircuit reakers Special Purpose ircuit reakers PowerMark Gold and Plus Single-Phase Load enters Main Lug onvertible to Main reaker Main reaker Factory Installed PowerMark Plus Three-Phase Load enters Main ircuit reakers or Main Lugs Factory Installed PowerMark Gold Load enters Specialty Panels PowerMark Gold Meter Socket Load enters Field Installed ccessories Wiring iagrams Load enters and Meter Socket Load enters nockouts ata subject to change uylog atalog 1-1

2 Load enters and ircuit reakers Q-Line ircuit reakers Reliability and conomy Special Purpose ircuit reakers PowerMark Gold Main ircuit reakers rc Fault ircuit Interrupter 3 Ground Fault ircuit Interrupter Switching Neutral HI Lighting reaker High Magnetic reaker Molded ase Switch Surge rrester TQ reaker opper stabs, tin-plated for corrosion resistance, make the connection reliable and permanent. Heat-resistant thermoset cases and covers add stability and structural rigidity. Trips are easy to spot because handles trip to the center position. The dedicated calibration screw is cemented (not simply papered over) to prevent shifting. The result is stable calibration for optimum trip performance. t 1/2, THQP breakers are half the width of standard breakers, permitting the use of smaller load centers that save money and space in both new construction and service upgrades. They feature the same high-performance design, and meet the same stringent standards as other Q- Line breakers. Our 1 THQL will remain the breaker of choice for many contractors. In applications where space and cost are not critical, they re an excellent choice. ut when size and money are driving considerations, THQP breakers are the smart choice. nclosed circuit breakers make it easy and efficient to install exterior main breakers. Maximum protection against all-too-common electrical fires comes from the new technology built into G s arc fault circuit interrupters (FIs). With its ability to detect and interrupt arcing caused by damaged wire insulation or a frayed extension cord, the FI takes home and family protection to a new, higher level. THQLSURG surge arresters are easy to install and protect the whole house computers, fax machines, televisions, stereos, VRs and other sensitive electronic equipment from destructive surges. The N requires ground fault protection of receptacles outdoors and in garages, bathrooms and spa areas. These ground fault circuit interrupters eliminate the need for separate GFI receptacles, protect against short circuits and overloads, and prevent shock by detecting very low levels of current leaks and immediately shutting off power to the circuit. 1-2 uylog atalog ata subject to change

3 Load enters and ircuit reakers PowerMark Gold Load enters Highest Quality and onvenience PowerMark Gold load centers lower your costs by making installation faster and easier, increasing application flexibility and reducing inventory requirements. t the same time, they deliver obvious and significant advances in design, function and quality. UL Listed (Panelboards No. 67) Suitable for Use as Service ntrance quipment when installed in accordance with National lectrical ode 60 /75 onductor Rating Single phase, , 2-42 circuits Main lug models field convertible to main breaker Main breaker 22kI standard - factory installed ll load centers top or bottom feed Indoor and outdoor rated enclosures Indoor fronts combination surface/flush opper bus with tin plating standard 1 Split neutrals extend the full length of the interior for ease of wiring ntire main lug line converts easily to main breaker ombination surface/flush front with spring-reinforced pan ombination slotted/robertson square-drive screws on neutral, 2 ground, front and breaker lugs packed in inner carton for added protection Field installable feed-through lugs up to 200 Straight-through main wiring Main breaker is clearly marked and circuit numbers are stamped on front Isolated ground bar is available ompact box maintains optimum wire-bending space One-piece interior removes and reinstalls easily Full-length neutrals are easier to wire, 2 reducing installation time and cost Minimum 100% neutral terminations Sturdy copper bus and galvanized box increase durability and reliability ccepts G Q-Line branch circuit breakers, including G s exclusive 1/2" THQPs Main breaker configuration allows top or bottom feed without modification ombination slotted/robertson square-drive speeds screw wiring ll holes rated for 14-4 wire 100% rated split neutral on each side 2 Tie bar may be removed to split neutral/ground Packaging features comprehensive selection and application data. s are packed in inner cartons for added protection during shipment and at the job site. complete family of meter socket load centers ring style and ringless, wide and narrow, meter mains, farm panels and more deliver specialized solutions for special situations. The PowerMark Gold line includes a wide range of outdoor as well as indoor units. Main lug load centers offer an economical solution for subpanels and similar applications. ll main lug units 125 and above convert easily to main breaker. ccessories and Options oor lock and handle Hardware kits quipment ground kits Main breaker retainers Sub-feed and feed-thru lugs Neutral kits filler plates Universal raintight hubs Handle lock and ties 1 Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs circuit and above. G s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kI ratings, and all the accessories needed to complete the job. Safety accessories convenient and easy to install THQLSURG whole house surge protector rc fault circuit interrupter breaker, 1- or 2-pole Ground fault circuit interrupter breaker, 5m and 30m Generator transfer panel 30 or 60, indoor or outdoor G disconnects ata subject to change uylog atalog 1-3

4 Load enters and ircuit reakers PowerMark Gold and Plus Load enters Number Guides Number Guide for Load enters ( number for illustrative purposes only) T M U G Identification Type M = Main breaker L = Main lug LM = onvertible PL = Main lug (Thermoplastic) Maximum Number 1" Spaces 2, 4, 6 42 Insert for 3-Phase 4-Wire Load enters Insert for Specials G or T = Factory installed ground bar = ottom feed main breaker FL = Factory installed feed-through lugs = Optional door for 6-8 circuit panel. (oors standard on all units 12 circuits or greater) W = White Insert for PowerMark Gold U = opper us 42 = opper us Full 42 circuit panel nclosure Type = ombination surface/flush F = Flush S = Surface R = Outdoor us mpere Rating 40 = 40 mps 20 = 200 mps 70 = 70 mps 22 = 225 mps 10 = 100 mps 30 = 300 mps 12 = 125 mps 40 = 400 mps 15 = 150 mps 60 = 600 mps Number Guide for Q-Line Plug-in ircuit reakers ( number for illustrative purposes only) T H QL 1 1* 15 GF G Identification Interrupting Rating H = 10kl HH = 22kl X = 65kl Type QL = 1" plug-in QP = 1/2" plug-in Q = 1" bolt-on Poles (1, 2, 3) Voltage 1 = 120/240V 2 = 240V mpere Rating Ground Fault/rc Fault ircuit Interrupter GF = 1-pole Ground Fault ircuit Interrupter 5 m GF1= 2-pole Ground Fault ircuit Interrupter 5 m F = 1- & 2-pole rc Fault ircuit Interrupter F2 = 1- & 2-pole ombination rc Fault ircuit Interrupter GFP = 1- & 2-pole Ground Fault ircuit Interrupter 30 m GFT = 1- & 2-pole self-test Ground Fault ircuit Interrupter - 5 m *Omit character for THQP breakers, which are all 120/240V. 1-4 uylog atalog ata subject to change

5 Load enters and ircuit reakers Q-Line Plug-in ircuit reakers UL Listed (Molded ase ircuit reakers No. 489) Federal Government Specification Qualified (W-375) 60 / 75 onductor Rating Quick Make, Quick reak ox Type Terminals Q-Line Plug-in ircuit reakers Specifications THQP130 THQP230 THQL1120 Wire Size WG/kcmil 1 reaker Type mpere Rating u l THQP THQL THHQL /0 4-1/0 TXQL /0 2-2/0 1 Solid or stranded for WG THQL2140 THQL32015 Q-Line Plug-in ircuit reakers 10,000I 22,000I 65,000I Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module 120/240 Vac 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 120/240 Vac mpere Rating Number Number Number Number Number Number Single Pole THQP115 THQL1115 THHQL1115 TXQL THQP120 THQL1120 THHQL1120 TXQL THQP125 THQL1125 THHQL1125 TXQL THQP130 THQL1130 THHQL1130 TXQL THQP135 THQL1135 THHQL THQP140 THQL1140 THHQL THQP145 THQL1145 THHQL THQP150 THQL1150 THHQL1150 Std. Pkg. 5 cartons of 20 5 cartons of 10 5 cartons of 10 5 cartons of 10 Two-Pole 3 : Incorporates Internal ommon Trip ar 15 THQP215 THQL2115 THQL THHQL2115 THHQL TXQL THQP220 THQL2120 THQL THHQL2120 THHQL TXQL THQP225 THQL2125 THQL THHQL2125 THHQL TXQL THQP230 THQL2130 THQL THHQL2130 THHQL TXQL THQP235 THQL2135 THQL THHQL2135 THHQL THQP240 THQL2140 THQL THHQL2140 THHQL THQP245 THQL2145 THQL THHQL2145 THHQL THQP250 THQL2150 THQL THHQL2150 THHQL THQL2160 THQL THHQL2160 THHQL THQL2170 THQL THHQL2170 THHQL THQL2180 THQL THHQL2180 THHQL THQL2190 THQL THHQL2190 THHQL THQL21100 THQL THHQL21100 THHQL THQL21110 THHQL THQL21125 THHQL21125 Std. Pkg. 5 cartons of 10 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 Three-Pole 3 : Incorporates Internal ommon Trip ar 15 THQL32015 THHQL32015 TXQL THQL32020 THHQL32020 TXQL THQL32025 THHQL32025 TXQL THQL32030 THHQL32030 TXQL THQL32035 THHQL THQL32040 THHQL THQL32045 THHQL THQL32050 THHQL THQL32060 THHQL THQL32070 THHQL THQL32080 THHQL THQL32090 THHQL THQL32100 THHQL32100 Std. Pkg. 5 cartons of 3 5 cartons of 3 5 cartons of 3 1 UL Listed as HR (heating, air conditioning and refrigeration). UL Listed as SW (switching duty). Suitable for 120 volts ac fluorescent lighting References: loads. ccessories Pages 1-24 thru amp UL Listed as HR (heating air conditioning and refrigeration). uxiliary Switches and Shunt Trips uylog pages 6-40 thru Required for three-phase and High Leg elta Systems only. ata subject to change uylog atalog 1-5

6 Load enters and ircuit reakers Special Purpose ircuit reakers 60 / 75 F onductor Rating ox Type Terminals Quick-Make, Quick-reak Multi-pole reakers Incorporate Internal ommon Trip rc Fault 2 UL Listed rc-fault ircuit Interrupters No mpere Rating 1 Pole, 120/240 Volts ac 1 Number 10,000 I 15 THQL1115F2 20 THQL1120F2 22,000 I 15 THHQL1115F2 20 THHQL1120F2 Std. Pkg. 10 artons of 1 s of Jan. 1, 2008, 2005 N requires combination FI. 1 ombination FI compliant with 2008 N and later 2 For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See T-719 for more details on our rc Fault products. ual Function GFI/FI Ground Fault & ombination rc Fault ircuit reaker UL Listed (vailable ecember 2014) 1 Pole, 120 Volts ac mpere Rating Number 10,000 I 15 THQL1115F 20 THQL1120F 22,000 I 15 THHQL1115F 20 THHQL1120F Std. Pkg. 10 artons of 1 Ground Fault UL Listed Ground Fault ircuit Interrupters No lass (5 milliamperes ground fault trip level). 1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac mpere Rating Number Number 10,000 I 15 THQL1115GF THQL2115GF1 20 THQL1120GF THQL2120GF1 30 THQL1130GF THQL2130GF1 40 THQL2140GF1 50 THQL2150GF1 22,000 I 15 THHQL1115GF 20 THHQL1120GF 30 THHQL1130GF Std. Pkg. 10 cartons of 1 10 cartons of 1 Ground Fault with Self-Test Feature culus Ground Fault ircuit Interrupters UL943 ed5 (5 milliamperes) 10,000 I 22,000 I 3 UL & S 1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac mpere Rating Number Number 15 THQL1115GFT THQL2115GFT 20 THQL1120GFT THQL2120GFT 25 THQL1125GFT THQL2125GFT 30 THQL1130GFT THQL2130GFT 40 THQL2140GFT 3 50 THQL2150GFT 3 15 THHQL1115GFT 20 THHQL1120GFT 25 THHQL1125GFT 30 THHQL1130GFT PowerMark Gold Main ircuit reakers for use with PowerMark Gold Load enters (Includes mounting base) UL Listed. escription mpere Rating Number Lug Size 100 THQMV THQMV125 Main ircuit reaker its 150 THQMV (cu), 22,000 I 175 THQMV175 2/ THQMV THQMV225 Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is converted to main breaker. rc Fault THQL1115F THQL1120GF THQL2150GFT THQMV100 with filler plates 1-6 uylog atalog ata subject to change

7 Load enters and ircuit reakers Special Purpose ircuit reakers 60 / 75 F onductor Rating ox Type Terminals Quick-Make, Quick-reak Multi-pole reakers Incorporate Internal ommon Trip PowerMark Gold Main ircuit reaker it For use with 125 PowerMark Gold load enters; 22kI RMS symmetrical. escription Number Main ircuit reaker it - Order appropriate THQL TQMH kI or THHQL 22kI breakers separately 1 Please review the footnotes listed with the individual Load enter product numbers for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with 24 suffix, and the TLM812RU2. Ground Fault with quipment Protection culus Ground Fault ircuit Interrupters No milliampere ground fault trip level 1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac mpere Rating Number Number 10,000 I 15 THQL1115GFP THQL2115GFP 20 THQL1120GFP THQL2120GFP 30 THQL1130GFP THQL2130GFP Std. Pkg. 10 artons of 1 10 artons of 1 Switching Neutral UL Listed. 10kI RMS symmetrical. Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole. 1-Pole Plus Switching Neutral 2-Pole Plus Switching Neutral 120/240 Volts ac 120/240 Volts ac mpere Rating Number Number 15 THQL21WY15 THQL31WY15 20 THQL21WY20 THQL31WY20 25 THQL21WY25 THQL31WY25 30 THQL21WY30 THQL31WY30 Std. Pkg. 5 cartons of 5 5 cartons of 3 "HI" Lighting UL Listed as HI. HI breakers have been designed to handle the current and voltage spikes that result when gaseous discharge lamps, including fluorescent and HI lamps, are switched on and off. 1-Pole, 120/240 Volts ac 2-Pole, 120/240 Volts ac mpere Rating Number Number 10,000 I 15 THQL1115HI 2 THQL2115HI 20 THQL1120HI 2 THQL2120HI 30 THQL1130HI THQL2130HI 22,000 I 15 THHQL1115HI 2 THHQL2115HI 20 THHQL1120HI 2 THHQL2120HI 30 THHQL1130HI THHQL2130HI Std. Pkg. 5 cartons of 10 5 cartons of 5 2 UL Listed as SW (switching duty). Suitable for 120 volts ac fluorescent lighting loads. High Magnetic UL Listed. 10kI RMS symmetrical High short circuit setting suitable for circuits with inherent high-inrush load currents. mpere Rating 1-Pole, 120/240 Volts ac Number 15 THQL1115HM 20 THQL1120HM 25 THQL1125HM 30 THQL1130HM 40 THQL1140HM 50 THQL1150HM Std. Pkg. 5 cartons of 10 TQMH000 THQL21WY30 THQL2120HI THQL1140HM Prices and data subject to change uylog atalog 1-7

8 Load enters and ircuit reakers Special Purpose ircuit reakers 60 / 75 F onductor Rating ox Type Terminals Quick-Make, Quick-reak Multi-pole reakers Incorporate Internal ommon Trip Molded ase Switches UL Listed Without overload or short circuit protection. 2-Pole 3-Pole mpere Rating Number Number 120/240 Volts ac 60 TQL21Y TQL21Y Volts ac 60 TQL22Y60 TQL32Y TQL22Y100 TQL32Y100 Std. Pkg. 5 cartons of 5 5 cartons of 3 Interlocking ircuit reakers for use in PowerMark Gold Generator Panels Two breakers required for interlocking. Poles mpere Rating Number 2 30 THQL2130GN 2 60 THQL2160GN TQ ircuit reakers 3/4" UL lassified ircuit reakers for use in *Square **QO Load enters. 10 ki RMS symmetrical 1-Pole 2-Pole mpere Rating Number Number 15 TQ1115 TQ TQ1120 TQ TQ1130 TQ TQ1140 TQ TQ1150 TQ TQ2160 Std. Pkg. 1 carton of 10 1 carton of 5 THQL 120/240 Vac, with Factory Installed Shunt 1 # of mpere 120/240 Vac Poles Rating Wire Range 2 Interrupting Rating Number 1 15 (1) 14-8 u/12-8 l 10k THQL1115ST (1) 14-8 u/12-8 l 10k THQL1120ST (1) 14-8 u/12-8 l 10k THQL1130ST (1) 8-3 u/8-3 l 10k THQL1135ST (1) 8-3 u/8-3 l 10k THQL1140ST (1) 8-3 u/8-3 l 10k THQL1145ST (1) 8-3 u/8-3 l 10k THQL1150ST1 1 Shunt trip requires one additional pole of space. THQL 120/240 Vac, Internal ommon Trip with Factory Installed Shunt 1 # of mpere 240 Vac Poles Rating Wire Range 2 Interrupting Rating Number u/12-8 l 10k THQL2115ST u/12-8 l 10k THQL2120ST u/12-8 l 10k THQL2130ST u/8-3 l 10k THQL2135ST u/8-3 l 10k THQL2140ST u/8-3 l 10k THQL2145ST u/8-3 l 10k THQL2150ST u/8-3 l 10k THQL2160ST /0 u/4-1/0 l 10k THQL2170ST /0 u/4-1/0 l 10k THQL2180ST /0 u/4-1/0 l 10k THQL2190ST /0 u/4-1/0 l 10k THQL21100ST u/12-8 l 10k THQL32020ST u/12-8 l 10k THQL32030ST u/8-3 l 10k THQL32040ST u/8-3 l 10k THQL32050ST u/8-3 l 10k THQL32060ST /0 u/4-1/0 l 10k THQL32070ST /0 u/4-1/0 l 10k THQL32080ST /0 u/4-1/0 l 10k THQL32090ST /0 u/4-1/0 l 10k THQL32100ST1 2 Solid or stranded for WG. *Square is a registered trademark of SN Holdings, Inc. **QO is a registered trademark of the Square ompany. TQL21Y100 TQ1120 THQL1130ST1 THQL2120ST1 THQL32020ST1 1-8 uylog atalog ata subject to change

9 Load enters and ircuit reakers PowerMark Gold and Plus Load enters Single-Phase, Three-Wire, 120/240 Vac Main Lugs onvertible to Main reaker Load enter 1PH Main Lug Indoor NM 1 Features UL Listed (Panelboards No. 67) 60 /75 onductor Rating Suitable for Use as Service ntrance quipment when Installed in ccordance with the National lectrical ode 22kI RMS symmetrical, xcept Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For a listing of S Listed load centers, visit geindustrial.com. TLM2020U TPL412R Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type 1 Number u-l Ground it Number Surface Top TG4 (order separately) TL240SU 1,8 ottom Surface Top TG4 (order separately) TL270SU 1,8 ottom ombination Top 2 1-2/0 TGL1 (order separately) TL412 1,2,8 Flush/Surface ottom ombination Top 2 1-2/0 TGL1 installed TL412T 1,2,3,8 Flush/Surface ottom Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412 1,2,3,8 ottom Thermoplastic Top 2 1-2/0 TGL1 installed TPL412T 1,2,3,8 ottom Flush Top TGL2 (order separately) TLM612FU 4,8 ottom Flush Top TGL2 (order separately) TLM612FU 4,8 ottom Flush Top TGL2 installed TLM612FUG 4,8 ottom Surface Top TGL2 (order separately) TLM612SU 4,8 ottom Surface Top TGL2 (order separately) TLM612SU 4,8 ottom Surface Top TGL2 installed TLM612SUG 4,8 ottom Flush Top TGL2 (order separately) TLM812FU 4,8 ottom Flush Top TGL2 (order separately) TLM812FU 4,8 ottom Flush Top TGL2 (order separately) TLM812FUG 4,8 ottom Surface Top TGL2 (order separately) TLM812SU 4,8 ottom Surface Top TGL2 (order separately) TLM812SU 4,8 ottom Surface Top TGL2 installed TLM812SUG 4,8 ottom ombination Top /0 Included 10 TLM1212U 7,8 Flush/Surface ottom White ombo Top /0 Included 10 TLM1212UW 7,8,9 Flush/Surface ottom This table continued on next page ata subject to change uylog atalog 1-9

10 Load enters and ircuit reakers PowerMark Gold and Plus Load enters Single-Phase, Three-Wire, 120/240 Vac Main Lugs onvertible to Main reaker Load enter 1PH Main Lug Indoor NM 1 Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number u-l Ground it Number ombination Top 4 6-2/0 TG12 and TG24 TLM1612U 5 Flush/Surface ottom (order separately) ombination Top 4 6-2/0 TG12 and TL20 TLM1612UG 7 Flush/Surface ottom installed ombination Top 7 6-2/0 TG24 and TG32 TLM2412U 5 Flush/Surface ottom (order separately) White ombo Top 7 6-2/0 TG24 and TG32 TLM2412UW 5,9 Flush/Surface ottom (order separately) ombination Top 7 6-2/0 TG24 and TL20 TLM2412UG 7 Flush/Surface ottom installed ombination Top TG32 TLM1620U 6 Flush/Surface ottom (order separately) White ombo Top TG32 TLM1620UW 6,9 Flush/Surface ottom (order separately) ombination Top TG32 TLM1620UG 6 Flush/Surface ottom installed ombination Top TG32 TLM2020U 6 Flush/Surface ottom (order separately) White ombo Top TG32 TLM2020UW 6,9 Flush/Surface ottom (order separately) ombination Top TG42 TLM2020UG 6 Flush/Surface ottom installed ombination Top 9 1-3/0 (u), TG24 and TL32 TLM Flush/Surface ottom 2/0-3/0 (l) (order separately) ombination Top (u), TG32 and TL20 TLM Flush/Surface ottom 2/0-250 (l) (order separately) ombination Top TG32 TLM3220U 6 Flush/Surface ottom (order separately) White ombo Top TG32 TLM3220UW 6,9 Flush/Surface ottom (order separately) ombination Top TG42 TLM4020U 6 Flush/Surface ottom (order separately) White ombo Top TG42 TLM4020UW 6,9 Flush/Surface ottom (order separately) ombination Top (u), TG42 TLM4220U 6 Flush/Surface ottom 2/0-300 (l) (order separately) ombination Top (u), TG42 TLM4222U 6 Flush/Surface ottom 2/0-300 (l) (order separately) 1 No door 2 10 ki amp maximum branch capacity. 4 For main breaker, order THQLR2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max. 5 For main breaker, order TQMH000. See page lso order 2-pole THQL, THHQL, or TXQL circuit breaker. See page For main breaker, order THQMVXXX circuit breaker from page For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLR3 breaker retainer (see page 1-28). 8 No lock provision available. Use next size larger load center such as TLM1612U with a TL106 accessory if locking provision is required. 9 Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See -590) 10 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page separate TGL2 can be added in the unlikey event that another ground bar is required. Note: See page 11-4, L Series Lighting Panelboards as replacements for load centers uylog atalog ata subject to change

11 Load enters and ircuit reakers PowerMark Gold and Plus Load enters Single-Phase, Three-Wire, 120/240 Vac Main Lugs onvertible to Main reaker Load enter 1PH Main Lug Outdoor NM 3R Main Lugs Factory Installed (TLM units convertible to main breaker), Outdoor (NM 3R) nclosure 1 Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed 1 ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number Top R TG4 (order separately) TL240RU Top R1 6-3 TG4 (order separately) TL270RU Flush Top R TGL1 installed TL510RT 2, Top R1 1-2/0 TGL1 (order separately) TL412R Top R1 1-2/0 TGL1 installed TL412RT Top R41 1-2/0 TGL1 (order separately) TL412R Thermoplastic Top R1 1-2/0 TGL1 (order separately) TPL412R 2, Thermoplastic Top R1 1-2/0 TGL1 installed TPL412RT 2, Top R2 6-1 TG12 (order separately) TLM612RU Top R2 6-1 TG12 (order separately) TLM812RU Top R3 6-1 TG12 (order separately) TLM812RU Top R3 6-2/0 Included TLM1212RU 7, Top R4 6-2/0 TG24 (order separately) TLM2412RU 5 ottom TG32 (order separately) Top R6 1-3/0 (u), TG24 (order separately) TLM2415RU 6 ottom 2/0-3/0 (l) TG32 (order separately) Top R TG24 (order separately) TLM1220RU Top R TG32 (order separately) TLM1620RU Top R TG24 (order separately) TLM2020RU 6 TG42 (order separately) Top R (u), TG24 (order separately) TLM2420R42 ottom 2/0-250 (l) Top R (u), 2/0-250 (l) TG32 (order separately) TLM3220RU 6 ottom Top R TG42 (order separately) TLM4020RU 6 ottom Top R (u), TG42 (order separately) TLM4222RU 6 ottom 2/0-300 (l) amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page ki amp maximum branch capacity. 4 For main breaker, order THQLR2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements. 5 For main breaker, order TQMH000. See page lso order 2-pole THQL or THHQL circuit breaker. See page For main breaker, order THQMVXXX circuit breaker from page For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLR3 breaker retainer (see page 1-28). 8 Main and branch breakers are limited to 70 amps. 9 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page separate TGL2 can be added in the unlikey event that another ground bar is required. Note: See page 11-4, L Series Lighting Panelboards as replacements for load centers. ata subject to change uylog atalog 1-11

12 Load enters and ircuit reakers PowerMark Gold and Plus Main reaker Load enters Single-Phase, Three-Wire, 120/240 Vac Main reaker Factory Installed Load enter 1PH Main reaker Indoor NM 1 Features UL Listed (Panelboards No. 67) 60 /75 onductor Rating Suitable for Use as Service ntrance quipment when Installed in ccordance with the National lectrical ode 22kI RMS symmetrical, xcept Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For a listing of S Listed load centers, visit geindustrial.com. TM2020U TM820RUFL Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number ombination Top /0 Included 1 TM1210U 2 Flush/Surface ottom ombination Top 7 1-2/0 TG24, TG32 and TM2410U Flush/Surface ottom TL20 (order separately) ombination Top 6 4-1/0 TG24 (order separately) TM2010U Flush/Surface ottom ombination Top /0 TG32 (order separately) TM3210U Flush/Surface ottom ombination Top /0 Included 1 TM1212U 2 Flush/Surface ottom ombination Top 7 1-2/0 TG24 (order separately) TM2412U Flush/Surface ottom ombination Top 4 1-2/0 TG12 (order separately) TM1612U Flush/Surface ottom TG24 (order separately) ombination Top 4 1-2/0 TG24 installed TM1612UG Flush/Surface ottom ombination Top 7 1-3/0 (u), TG24 (order separately) TM1615U Flush/Surface ottom 2/0-3/0 (l) TG32 (order separately) ombination Top 7 1-3/0 (u), TG32 installed TM1615UG Flush/Surface ottom 2/0-3/0 (l) This table continued on next page 1-12 uylog atalog ata subject to change

13 Load enters and ircuit reakers PowerMark Gold and Plus Main reaker Load enters Single-Phase, Three-Wire, 120/240 Vac Main reaker Factory Installed Load enter 1PH Main reaker Indoor NM 1 Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number ombination Top /0 (u), TG32 (order separately) TM3215U Flush/Surface ottom 2/0-3/0 (l) ombination Top 9 1-3/0 (u), TG24 (order separately) TM Flush/Surface ottom 2/0-3/0 (l) TL32 (order separately) ombination Top /0 (u), TG32 and TL20 TM Flush/Surface ottom 2/0-3/0 (l) (order separately) ombination Top (u), TG32 (order separately) TM1620U Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG32 installed TM1620UG Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG32 (order separately) TM2020U Flush/Surface ottom 2/0-250 (l) White ombo Top (u), TG24 (order separately) TM2020UW 3 Flush/Surface ottom 2/0-250 (l) TG42 (order separately) ombination Top (u), TG32 (order separately) TM2020UG Flush/Surface ottom 2/0-250 (l) White ombo Top (u), TG32 (order separately) TM2020UGW 3 Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG32 (order separately) TM3220U Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG42 (order separately) TM4020U Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG32 and TL20 TM Flush/Surface ottom 2/0-250 (l) (order separately) ombination Top (u), TG42 (order separately) TM4220U Flush/Surface ottom 2/0-300 (l) ombination Top (u), TG42 (order separately) TM4222U Flush/Surface ottom 2/0-300 (l) 1 Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page separate TGL2 can be added in the unlikey event that another ground bar is required. 2 No lock provision available. Use next size larger load center such as TLM1612U with a TL106 accessory if locking provision is required. 3 Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See -590) Outdoor (NM 3R) nclosure 4 Load enter 1PH Main reaker Outdoor NM 3R Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Number u-l Ground it Number Top R3 4-1/0 TG12 (order separately) TM1210RU TG24 (order separately) Top R4 4-1/0 TG24 (order separately) TM2010RU Top R3 1-2/0 TG12 (order separately) TM1212RU TG24 (order separately) Top R4 1-2/0 TG24 (order separately) TM2412RU Top R (u), 2/0-250 (l) TG24 (order separately) TM815RUFL Top R5 1-3/0 (u), 2/0-3/0 (l) TG24 (order separately) TM1615RU TG32 (order separately) Top R6 1-3/0 (u), 2/0-3/0 (l) TG24 (order separately) TM2415RU TG32 (order separately) Top R (u), 2/0-250 (l) TG24 (order separately) TM2415R42 ottom Top R7 1-3/0 (u), 2/0-3/0 (l) TG32 (order separately) TM3215RU Top R (u), 2/0-250 (l) TG32 (order separately) TM820RUFL Top R (u), 2/0-250 (l) TG24 (order separately) TM2020RU TG42 (order separately) Top R (u), 2/0-250 (l) TG24 (order separately) TM2420R42 ottom Top R (u), 2/0-250 (l) TG32 (order separately) TM3220RU Top R (u), 2/0-250 (l) TG42 (order separately) TM4020RU Top R (u), 2/0-250 (l) TG24 (order separately) TM822RUFL Top R (u), 2/0-300 (l) TG42 (order separately) TM4222RU amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page Note: See page 11-4, L Series Lighting Panelboards as replacements for load centers. ata subject to change uylog atalog 1-13

14 Load enters and ircuit reakers PowerMark Plus Load enters Three-Phase, Four-Wire, 208Y/120 Vac 2 Main Lugs Factory Installed Load enter 3PH Main Lugs Indoor NM 1 Features UL Listed (Panelboards No. 67) 60 /75 onductor Rating Suitable for Use as Service ntrance quipment when Installed in ccordance with the National lectrical ode 22kI RMS symmetrical Short-circuit Rating Standard ottom feed models available where noted with a suffix. For a listing of S Listed load centers, visit geindustrial.com. opper breaker mounting stabs with aluminum bus 1 Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size mpere pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number ombination Top 4 6-2/0 TG12 (order separately) TL Flush/Surface ottom TG24 (order separately) ombination Top 7 1-3/0 (u), TG24 (order separately) TL Flush/Surface ottom 2/0-3/0 (l) TG32 (order separately) ombination Top 7 1-3/0 (u), TG24 (order separately) TL Flush/Surface ottom 2/0-3/0 (l) TG32 (order separately) ombination Top (u), TG32 (order separately) TL Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG32 (order separately) TL Flush/Surface ottom 2/0-250 (l) ombination Top (u), TG42 (order separately) TL42420 Flush/Surface ottom 2/0-250 (l) ombination Top (u), (2) TGL2 (order separately) TL Flush/Surface ottom 2/0-300 (l) ombination Top (u), (2) TGL2 (order separately) TL Flush/Surface ottom 2/0-300 (l) 1 Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs, providing copper-to-copper contact at breaker stabs. 2 lso UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed. 3 lternate main breaker: 100 mp max. THQL three-pole, use retainer THQLR. See page Not suitable for use as service entrance equipment. Note: See page 11-4, L Series Lighting Panelboards as replacements for load centers uylog atalog ata subject to change

15 Load enters and ircuit reakers PowerMark Plus Load enters Three-Phase, Four-Wire, 208Y/120Vac 1 Main ircuit reaker or Main Lugs Factory Installed Load enter 3PH Main Lugs Outdoor NM 3R Main Lugs Factory Installed Outdoor (NM 3R) nclosure TM24420 Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size mpere pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Type Number u-l Ground it Number Top R3 6-2/0 TG12 (order separately) TL12412R 2,4 TG24 (order separately) Top R4 1-3/0 (u), TG24 (order separately) TL18415R 2,4 2/0-3/0 (l) TG32 (order separately) Top R4 1-3/0 (u), TG24 (order separately) TL24415R 2,4 2/0-3/0 (l) TG32 (order separately) Top R (u), TG32 (order separately) TL18420R 2,4 2/0-250 (l) Top R (u), TG32 (order separately) TL30420R 2,4 2/0-250 (l) Top R (u), TG42 (order separately) TL42420R 2,3 2/0-250 (l) Top R (u), TG42 (order separately) TL42422R 2,3 2/0-300 (l) 1 lso UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed mp three-phase devices have removable closing cap. Larger mpere devices require field cut openings. Order hubs separately. See page Not suitable for use as service entrance equipment. 4 lternate main breaker: 100 mp max. THQL three-pole, use retainer THQLR. See page Main reaker Factory Installed Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size mpere pole Feed 2 ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number ombination Top 6 6-1/0 (u), TG12 (order separately) TM Flush/Surface ottom 4-1/0 (l) TG24 (order separately) ombination Top 6 6-1/0 (u), TG24 (order separately) TM Flush/Surface ottom 4-1/0 (l) TG32 (order separately) ombination Top /0 (u), TG32 (order separately) TM30412 Flush/Surface 2/0-3/0 (l) ombination ottom /0 (u), TG32 (order separately) TM30412 Flush/Surface 2/0-3/0 (l) ombination Top /0 (u), TGL1, TGL2, TGL20,TNG3, TM24415 Flush/Surface 2/0-3/0 (l TGN6 (order separately) ombination ottom /0 (u), TG32 (order separately) TM24415 Flush/Surface 2/0-3/0 (l) ombination Top /0 (u), TG32 (order separately) TM30415 Flush/Surface 2/0-3/0 (l) ombination ottom /0 (u), TG32 (order separately) TM30415 Flush/Surface 2/0-3/0 (l) ombination Top /0 (u), TG42 (order separately) TM42415 Flush/Surface 2/0-3/0 (l) ombination ottom /0 (u), TG42 (order separately) TM42415 Flush/Surface 2/0-3/0 (l) ombination Top (u), TG32 (order separately) TM24420 Flush/Surface 2/0-300 (l) ombination ottom (u), TG32 (order separately) TM24420 Flush/Surface 2/0-300 (l) Load enter 3PH Main reaker Indoor NM 1 5 lso UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed mp indoor devices UL listed for bottom-feed by installing complete unit upside-down. This table continued on next page Note: See page 11-4, L Series Lighting Panelboards as replacements for load centers. ata subject to change uylog atalog 1-15

16 Load enters and ircuit reakers PowerMark Plus Load enters Three-Phase, Four-Wire, 208Y/120 Vac 1 Main ircuit reaker Factory Installed Load enter 3PH Main reaker Indoor NM 1 Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size mpere pole Feed 2 ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number ombination Top (u), TG32 (order separately) TM30420 Flush/Surface 2/0-250 (l) ombination ottom (u), TG32 (order separately) TM30420 Flush/Surface 2/0-250 (l) ombination Top (u), TG42 (order separately) TM42420 Flush/Surface 2/0-250 (l) ombination ottom (u), TG42 (order separately) TM42420 Flush/Surface 2/0-250 (l) ombination Top (u), (2) TGL2 (order separately) TM42422 Flush/Surface 2/0-300 (l) ombination ottom (u), (2) TGL2 (order separately) TM42422 Flush/Surface 2/0-300 (l) 1 lso UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed. Outdoor (NM 3R) nclosure Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size mpere pole Feed 2 ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Type Number u-l Ground it Number Top R4 6-1/0 (u), TG24 (order separately) TM18410R 2 4-1/0 (l) TG32 (order separately) Top R7 1-3/0 (u), TG32 (order separately) TM30412R 2 2/0-3/0 (l) Top R6 1-3/0 (u), TG32 (order separately) TM24415R 2 2/0-3/0 (l) Top R7 1-3/0 (u), TG32 (order separately) TM30415R 2 2/0-3/0 (l) Top R (u), TG32 (order separately) TM30420R 2 2/0-250 (l) Top R (u), TG42 (order separately) TM42420R 2 2/0-250 (l) Top R (u), TG42 (order separately) TM42422R 2 2/0-300 (l) mp three-phase devices have removable closing cap. Larger mpere devices require field cut openings. Order hubs separately. See page Load enter 3PH Main reaker Outdoor NM 3R Note: See page 11-4, L Series Lighting Panelboards as replacements for load centers uylog atalog ata subject to change

17 Load enters and ircuit reakers PowerMark Gold Load enters Single-Phase, Three-Wire, 120/240 Vac Load enter Generator Panels Riser Panels Spa Panels Features - Generator Panels Suitable for use in accordance with rticle 702 of the National lectrical ode, NSI/NFP 70 Single-phase, 2 interlock 60 or 30 main breakers, 8 circuits max. Safety and convenience when using a generator - 14,000 peak wattage, 11,520 continuous load, 48 amps at 240 volts. Maintains power to such critical circuits as those for furnace, pump, refrigerator, lights. onnected dual breaker mechanism ensures that only one source is active at a time. Generator Panels, Two Interlocked Main reakers Factory Installed Indoor (NM 1) nclosure TL412R250GF TM830FUGN Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number Flush Top TG12 included TM830FUGN ottom Surface Top TG12 included TM830SUGN ottom Flush Top TG12 included TM860FUGN ottom Surface Top TG12 included TM860SUGN ottom Generator Panels, Two Interlocked Main reakers Factory Installed Outdoor (NM 3R) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Number u-l Ground it Number Top R2 6-1 TG12 included TM830RUGN Top R2 6-1 TG12 included TM860RUGN Riser Panels Indoor (NM 1) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number ombination Top 9 6-2/0 TG12 (order TLM2012URP Flush/Surface separately) Tap kits required, order separately. See page uxiliary gutters available. See page Spa Panels Outdoor (NM 3R) nclosure Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size mpere 1 1 1/2 1/2 1-pole Load enter Feed ox (WG/kcmil) quipment Rating Spaces Spaces Spaces Spaces Spaces Type Type Number u-l Ground it Number Factory Included Top 1-2/0 TGL1 installed TL412R250GF 50 GFI ottom Factory Included Top 1-2/0 TGL1 installed TL412R260GF 60 GFI ottom Twist Lock Power Inlets Receptacles mps Volts UL Number L /240 anada, US T020N L /240 anada, US T030N S /240 anada, US T050N ata subject to change uylog atalog 1-17

18 Load enters and ircuit reakers PowerMark Gold Meter Socket Load enters Single-Phase, Three-Wire, 120/240 Vac With onded Neutrals Meter Socket L 1PH Ring Type Meter Main NM 3R esigned and manufactured for quality applications, these PowerMark Gold Meter Socket Load enters are a superior solution to specific applications. Increased durability and reliability, maximum circuit layout flexibility and ease of installation add up to lower total installed cost. The Ringless UL Style meter socket load centers (Florida Meter Group, Georgia Power, Others) are specifically designed to meet UL requirements as well as some special features required by specific utilities. If your local utility does not require specific approval and you need a ringless meter socket load center, use the Florida Meter Group style. TSM2020FU Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Meter Main - Ring Type, Field Installed Mains Outdoor Semi-Flush None OH/UG UL TSL210FU 1 (NM 3R) USR Outdoor Surface 2 None OH/UG UL TSL210SU 1,2,3 (NM 3R) USR Outdoor Surface 2 None OH/UG UL TSL412SU 1,2,3 (NM 3R) USR Outdoor Semi-Flush None OH/UG UL TSL420FU 1,4,5 (NM 3R) USR Outdoor Surface 2 None OH/UG UL TSL420SU 1,2,3,4 (NM 3R) USR Meter Main - Factory Installed Mains Outdoor Surface 2 None OH/UG UL TM10RM 2 (NM 3R) Outdoor Surface 2 None OH/UG UL TM12RM 2 (NM 3R) Outdoor Surface 2 None OH/UG UL TM15RM 2 (NM 3R) Outdoor Surface 2 None OH/UG UL TM20RM 2 (NM 3R) 1 ccepts field installed fifth jaw terminal in the 3 or 9 o clock position. number TJW53; order separately. 2 evices include removable closing cap. Order hub separately. See page Surface mounted units have two hub provisions on top end wall. 4 THQL and THHQL only, 125 amp max. TQL is obsolete. 5 Restricted pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. Field Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc Svcs isc u-l Ground it TSL210FU R /2 4-7/8 THQP/THQL 6-2/0 TGL1 installed TSL210SU R /2 4-7/8 THQP/THQL 6-2/0 TGL1 installed TSL412SU R /2 4-7/8 THQP/THQL 6-2/0 TGL1 installed TSL420FU R /4 5-3/4 THQP/THQL TGL1 installed TSL420SU R /4 5-3/4 THQP/THQL TGL1 installed TM10RM R TQ Field Installed TM12RM R TQ Field Installed TM15RM R TQ Field Installed TM20RM R TQ Field Installed uylog atalog ata subject to change

19 Load enters and ircuit reakers PowerMark Gold Meter Socket Load enters Single-Phase, Three-Wire, 120/240 Vac With onded Neutrals Ring Type - Farm Panel - Main reaker Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Outdoor Surface None OH/UG UL TSF420SU 1,2 (NM 3R) USR 1 evices include removable closing cap. Order hub separately. See page Separate field mounted service disconnect can be added, THQL/THHQL. See wiring diagram on page pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. Field Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc Svcs isc u-l Ground it TSF420SU R / /16 THQMV THQL/THHQL TG12 (order separately) Ring Type Feed-Thru - Main reaker Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Outdoor Surface None OH/UG UL TSM415SU 1 (NM 3R Outdoor Surface None OH/UG UL TSM815SU 1 (NM 3R) Outdoor Surface None OH/UG UL TSM815SFL 1 (NM 3R) Outdoor Surface None OH/UG UL TSM420SU 1 (NM 3R) Outdoor Surface None OH/UG UL TSM820SU 1 (NM 3R Outdoor Surface None OH/UG UL TSM820SFL 1 (NM 3R) 1 evices include removable closing cap. Order hub separately. See page pplication ata Meter Socket L 1PH Ring Type Farm Panel Main reaker NM 3R Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSM415SU R /2 4-1/2 THQMV TGL2 included TSM815SU R / /16 THQMV TG12 (order separately) TSM815SFL R /4 4-1/2 THQMV TG24 included TSM420SU R /2 4-1/2 THQMV TGL2 included TSM820SU R / /16 THQMV TG12 (order separately) TSM820SFL R /4 4-1/2 THQMV TG24 included ata subject to change uylog atalog 1-19

20 Load enters and ircuit reakers PowerMark Gold Meter Socket Load enters Single-Phase, Three-Wire, 120/240 Vac With onded Neutrals Ring Type - Side by Side - Main reaker - OH/UG Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Outdoor Semi-Flush None OH/UG UL/USR TSM1610FU Outdoor Semi-Flush None OH/UG UL/USR TSM1212FU Outdoor Semi-Flush None OH/UG UL/USR TSM1612FU Outdoor Semi-Flush None OH/UG UL/USR TSM2020FU Outdoor Surface None OH/UG UL/USR TSM1610SU 1,2, Outdoor Surface None OH/UG UL/USR TSM1212SU 1,2, Outdoor Surface None OH/UG UL/USR TSM1612SU 1,2, Outdoor Surface None OH/UG UL/USR TSM2020SU 1,2,3 1 ccepts field installed fifth jaw terminal in the 3 or 9 o clock position. number TJW53; order separately. 2 evices include removable closing cap. Order hub separately. See page Surface mounted units have two hub provisions on top end wall. pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSM1610FU R /4 28-1/2 7-5/16 THHQL 12-2/0 TG12 (order separately) TSM1212FU R /4 28-1/2 7-5/16 THHQL 12-2/0 TG12 (order separately) TSM1612FU R /4 28-1/2 7-5/16 THHQL 12-2/0 TG12 (order separately) TSM2020FU R /4 34-1/4 7-5/16 THQMV TG12 (order separately) TSM1610SU R /4 27-5/16 5-7/16 THHQL 12-2/0 TG12 (order separately) TSM1212SU R /4 27-5/16 5-7/16 THHQL 12-2/0 TG12 (order separately) TSM1612SU R /4 27-5/16 5-7/16 THHQL 12-2/0 TG12 (order separately) TSM2020SU R / /16 THQMV TG12 (order separately) Ring Type - xtra Wide - Main reaker Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Outdoor Surface None UG UL/USR TSM3220UWU Outdoor Surface None UG UL/USR TSM4020UWU 2 2 evices include removable closing cap. Order hub separately. See page pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSM3220UWU R /2 27-7/8 6-1/4 THQMV TG12 (order separately) TSM4020UWU R /2 34-7/8 6-1/4 THQMV TG12 (order separately) Ring Type - Top/ottom - Main reaker Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Outdoor Semi-Flush None UG UL/USR TSM2420UF Outdoor Semi-Flush None UG UL/USR TSM3220UFU Outdoor Semi-Flush None UG UL/USR TSM2022UFU Outdoor Semi-Flush None UG UL/USR TSM3222UFU Outdoor Surface None UG UL/USR TSM2420US42 1,2, Outdoor Surface None UG UL/USR TSM3220USU Outdoor Surface None UG UL/USR TSM2022USU Outdoor Surface None UG UL/USR TSM3222USU 1 1 ccepts field installed fifth jaw terminal in the 3 or 9 o clock position. number TJW53; order separately. 2 evices include removable closing cap. Order hub separately. See page Surface mounted units have two hub provisions on top end wall. pplication ata Meter Socket L 1PH Ring Type Narrow, Wide, Over/Under Main reaker NM 3R Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSM2420UF42 R /4 34-1/4 7-5/16 THQMV 1-4/0 TG12 (order separately) TSM3220UFU R / /8 7-3/16 THQMV TG12 (order separately) TSM2022UFU R / /8 7-3/16 THQMV TG12 (order separately) TSM3222UFU R / /8 7-3/16 THQMV TG12 (order separately) TSM2420US42 R /4 34-1/4 7-5/16 THQMV 1-4/0 TG12 (order separately) TSM3220USU R / /8 6-3/16 THQMV TG12 (order separately) TSM2022USU R / /8 6-3/16 THQMV TG12 (order separately) TSM3222USU R / /8 6-3/16 THQMV TG12 (order separately) 1-20 uylog atalog ata subject to change

21 Load enters and ircuit reakers PowerMark Gold Meter Socket Load enters Single-Phase, Three-Wire, 120/240 Vac With onded Neutrals Meter Socket L 1PH Ringless with ypass Xcel nergy NM 3R Ringless with ypass - Xcel nergy Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure Main ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Type Incoming ertification Number Outdoor MLO Surface Horn ypass OH/UG Xcel/UL TSLR412SU 1 (NM 3R) Outdoor MLO Surface 1 Lever OH/UG Xcel/UL TSL412SU 1 (NM 3R) ypass Outdoor M Surface Horn ypass OH/UG Xcel/UL TSMR1212SU 1 (NM 3R) Outdoor M Surface Lever OH/UG Xcel/UL TSM1212SU 1 (NM 3R) ypass Outdoor M Surface Horn ypass OH/UG Xcel/UL TSMR415SU (NM 3R) Outdoor M Surface Horn ypass OH/UG Xcel/UL TSMR2015SU 1 (NM 3R) Outdoor M Surface Lever OH/UG Xcel/UL TSM2015SU 1 (NM 3R) ypass Outdoor MLO Surface 1 Lever OH/UG Xcel/UL TSL420SU 1 (NM 3R) ypass Outdoor MLO Surface Horn ypass OH/UG Xcel/UL TSLR420SU 1 (NM 3R) Outdoor M Surface Horn ypass OH/UG Xcel/UL TSMR420SU (NM 3R) Outdoor M Surface Horn ypass OH/UG Xcel/UL TSMR2020SU 1 (NM 3R) Outdoor M Surface Lever OH/UG Xcel/UL TSM2020SU 1 (NM 3R) ypass 1 evices include removable closing cap. Order hub separately. See page pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSLR412SU R / /16 6-3/16 Field Installed TG12 (order separately) TSL412SU R /2 4-7/8 Field Installed TGL1 installed TSMR1212SU R / /2 6-3/16 THHQL TG12 (order separately) TSM1212SU R /4 27-5/16 5-7/16 THHQL 12-2/0 TG12 (order separately) TSMR415SU R / /16 6-3/16 THQMV TG12 installed TSMR2015SU R / /2 6-3/16 THQMV TG12 (order separately) TSM2015SU R / /16 THQMV TG12 (order separately) TSL420SU R /4 5-3/4 Field Installed TGL1 installed TSLR420SU R / /16 6-3/16 Field Installed TG12 (order separately) TSMR420SU R / /16 6-3/16 THQMV TG12 installed TSMR2020SU R / /2 6-3/16 THQMV TG12 (order separately) TSM2020SU R / /16 THQMV TG12 (order separately) 2 THQL and THHQL only. 125 amp max. TQL is obsolete. ata subject to change uylog atalog 1-21

22 Load enters and ircuit reakers PowerMark Gold Meter Socket Load enters Single-Phase, Three-Wire, 120/240 Vac With onded Neutrals Georgia Power Ringless - Main reaker Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number 150 Outdoor Surface None OH/UG UL/GP TSMR015SGP 1,4 (NM 3R) 200 Outdoor Surface None OH/UG UL/GP TSMR020SGP 1,4 (NM 3R) Outdoor Surface None OH/UG UL/GP TSMR415SUGP 1,4 (NM 3R) Outdoor Surface None OH/UG UL/GP TSMR420SUGP 1,4 (NM 3R) pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSMR015SGP R /8 18-9/16 5 THQ TSMR020SGP R /8 18-9/16 5 THQ TSMR415SUGP R /2 THQMV TGL2 included TSMR420SUGP R /2 THQMV TGL2 included Florida Meter Group MSL Ringless - Main reaker Main mpere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole nclosure ypass UL gency Rating 1 Spaces 1 Spaces 1/2 Spaces 1/2 Spaces Spaces Type Type Type Incoming ertification Number Outdoor Surface None OH/UG UL/FMG TSMR415SFLFMG (NM 3R) Outdoor Surface None OH/UG UL/FMG TSMR420SFLFMG (NM 3R) Outdoor Surface None OH/UG UL/FMG TSMR815SFLFMG 4 (NM 3R) Outdoor Surface None OH/UG UL/FMG TSMR820SFLFMG 4 (NM 3R) Outdoor Surface None OH/UG UL/FMG TSMR2020SUFMG 2 (NM 3R) pplication ata Meter Socket L 1PH Ringless Georgia Power Florida Meter Group Main reaker NM 3R Main Wire Size ox Unit Width Unit Height epth Factory Inst. (WG/kcmil) quipment Number Number (in inches) (in inches) (in inches) Svcs isc u-l Ground it TSMR415SFLFMG R /2 4-1/2 THQMV TGL2 included TSMR420SFLFMG R /2 4-1/2 THQMV TGL2 included TSMR815SFLFMG R /4 4-1/2 THQMV TG24 included TSMR820SFLFMG R /4 4-1/2 THQMV TG24 included TSMR2020SUFMG R /2 4-1/2 THQMV TG24 included 1 Use FMG unit if Ringless standard UL design is required by your local utility. 2 No feed through lugs. 3 nock outs are the same as R36. 4 Feed-thru lugs provided uylog atalog ata subject to change

23 Load enters and ircuit reakers PowerMark Gold Meter Socket Load enters Single-Phase, Three-Wire, 120/240 Vac With onded Neutrals Meter Socket L 1PH lass 320 NM 3R lass 320 Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total mpere 1 1 1/2 1/2 1-pole nclosure ypass UL gency Rating Spaces Spaces Spaces Spaces Spaces Type Type Type Incoming ertification Number Outdoor Surf/Semi None UG UL TM2432RMS 1,2,3 (NM 3R) Outdoor Surf/Semi Lever ypass UG UL TSR040UFU 4 (NM 3R) Outdoor Surface Lever ypass UG UL TSR830USU 4 (NM 3R) FMG Outdoor Surface Lever ypass UG UL TSR840UFU 4 (NM 3R) FMG Outdoor Surf/Semi -4 olt-in UG UL TM2440RMS 1,2,3 (NM 3R) Meter Provision Outdoor Surf/Semi Lever ypass UG UL TM2440RMRS 1,2,3 (NM 3R) Outdoor Surf/Semi None UG UL TM2440RMS 1,2,3 (NM 3R) USR Outdoor Surf/Semi Lever ypass UG UL TMH2440RMRS 1,2,3,4 (NM 3R) Xcel Outdoor Surf/Semi None UG UL TMH2440RMS 1,2,3,4 (NM 3R) Outdoor Surf/Semi Lever ypass UG UL TS032UFU 4 (NM 3R) Outdoor Surf/Semi Link ypass UG UL TS2432U42 4 (NM 3R) USR Outdoor Surf/Semi Link ypass UG UL TS2440U42 4 (NM 3R) USR main breaker factory installed. Space provided for field mounted TQ-WL sub feed. 2 For semi-flush applications, order surface enclosure load center and field installed kit, number SF Stud provisions only provided ki. pplication ata Main Wire Size ox Unit Width Unit Height epth Factory Inst. Field Inst. (WG/kcmil) quipment Number Ringless Number (in inches) (in inches) (in inches) Main reaker Main reaker u-l Ground it TM2432RMS No R / TQ THQL (1) 800 or (2) 400 compression type; (2) TGL2 (1) 1000 or (2) compression type; (order separately) (1) 1000 or (2) 350 pressure type TM2440RMS No R / TQ TQ (1) 800 or (2) 400 compression type; (2) TGL2 (1) 1000 or (2) 350 pressure type (order separately) TMH2440RMS No R / THQ THQ (1) 800 or (2) 400 compression type; (2) TGL2 (1) 1000 or (2) 350 pressure type (order separately) TS2432U42 No R / THQ THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2 (order separately) TS2440U42 No R / THQ TQ/THQ (1) 800 or (2) 400 compression type (2) TGL2 (order separately) TS032UFU No R / /32 THQ THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2 (order separately) TM2440RMS Yes R / TQ TQ (1) 800 or (2) 400 compression type; (2) TGL2 (1) 1000 or (2) 350 pressure type (order separately) TM2440RMRS Yes R / TQ TQ (1) 800 or (2) 400 compression type; (2) TGL2 (1) 1000 or (2) 350 pressure type (order separately) TMH2440RMRS Yes R / THQ THQ (1) 800 or (2) 400 compression type; (2) TGL2 (1) 1000 or (2) 350 pressure type (order separately) TSR040UFU Yes R / /32 THQ TQ/THQ (1) 800 or (2) 400 compression type (2) TGL2 (order separately) TSR840UFU Yes R / /32 THQ TQ/THQ (1) 800 or (2) 400 compression type (2) TGL2 (order separately) ata subject to change uylog atalog 1-23

24 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Field Installed ccessories PowerMark Gold Main ircuit reaker it For use with 125 PowerMark Gold load enters; 22kI RMS symmetrical. escription Number Main ircuit reaker it - Order appropriate THQL TQMH kI or THHQL 22kI breakers separately 1 Please review the footnotes listed with the individual Load enter product numbers for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with 24 suffix, and the TLM812RU2. TQMH000 PowerMark Plus quipment Ground its escription Standard Package Quantity Number (4) 14-8u/12-8L, 20 TGL1 (3) 14-4u/6-4L (8) 14-8u/12-8L, 20 TGL2 1 (6) 14-4u/6-4L (7) 14-8u/12-8L, (3) 14-4u/6-4L, 20 TGL8 1 (2) 14-4u/12-4L, (1) 14-2u/L (1) 6-2/0u/l Number of Terminals, 20 TGL20 2 quipment Ground its (3) 10-1/0 u/l Number of Terminals 1 TNG3 3 for 400 and 600 mp (6) 10-1/0 u/l Number of Terminals 1 TNG6 4 for 400 and 600 mp TGL2, TGL4 and TGL8 mount interchangeably dd-on quipment Ground Lug (for use on any TGL it) 3 Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole TGL2 TGL20 combined with TGL1 PowerMark Gold quipment Ground and Isolated Ground ar its 4,5 escription Standard Package Quantity Number 4-hole Ground 1 TG4 12-hole Ground 1 TG12 24-hole Ground 1 TG24 32-hole Ground 1 TG32 42-hole Ground 1 TG circuit indoor load centers use PowerMark Plus style neutrals and grounds 5 dd TGIS for isolated ground and mount to ground kit. TG12 TG12 with TGIS 1-24 uylog atalog ata subject to change

25 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Field Installed ccessories PowerMark Plus Neutral its Wire Standard escription Range Package Quantity Number 400 & 600 mp PowerMark Plus Neutral it (5) 14-1/0 1 TNL & 600 mp PowerMark Plus Neutral it (3) TNL2 1 dd-on neutral lug for mp PowerMark 6-2/ G1 Plus load centers dd-on neutral lug for mp PowerMark u or G13 Plus load centers 2/0-300 l 1 Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole G G1 PowerMark Gold Neutral its Wire Standard escription Range Package Quantity Number PowerMark Gold Neutral it - 6-2/0 1 TNL20 Mounted on top of neutral only PowerMark Gold Neutral it TNL250 Mounted on top of neutral only TNL250 PowerMark Gold Neutral/Ground Lug its Mounted on any neutral or ground position by removing the termination screw Wire Standard escription Range Package Quantity Number Neutral/Ground Lug it 6-2/0 1 TL20 Neutral/Ground Lug it TL250 Neutral/Ground Lug it TL300 TL20 TL250 Isolated Ground us ars quipment Ground it Standard escription Package Quantity Number Isolated Ground ar it (order with 1 TGIS TG quipment Ground its) Isolated Ground ar Feet (Order with TG8) 1 TGIS2 Subfeed Lug its Standard escription Package Quantity Number Pole Plug-in 1 THL Pole Plug-in - For use with PowerMark Gold only 1 THL Pole Plug-in - For use with PowerMark Gold only 1 THL Pole Plug-in 1 THL Pole Plug-in - For use with 3 phase only 1 THL3225 TG12 with TGIS Sub-feed and Feed-thru Lugs UL Listed For use in load centers to economically supply power to a subpanel. Poles mpere Rating Number THL THL THL THL THL For use with PowerMark Gold load centers only 2 For use with three-phase load centers only. Includes mounting base. THL2125 ata subject to change uylog atalog 1-25

26 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Field Installed ccessories PowerMark Plus Main Lug its escription Wire Range (u/l) Number 150 mp PowerMark Plus Replacement Main Lug kit 2-3/0 THL mp PowerMark Plus Replacement Main Lug kit THL200 THL200 PowerMark Gold Main Lug its escription Wire Range (u/l) Number 125 mp PowerMark Gold Replacement Main Lug kit 6-2/0 TML mp PowerMark Gold Replacement Main Lug kit TML mp PowerMark Gold Replacement Main Lug kit TML225 For replacement of main lugs on 125 amp load centers; TLM load centers include main lugs. PowerMark Gold main lug kits - TML200 oor Lock Standard escription Package Quantity Number For indoor load centers larger than 12 circuits (oes not fit TPL412) 10 TL106 TL106 ircuit irectory Standard escription Package Quantity Number ard and holder with pressure-sensitive backing. 1 T42 Mounts inside the door. T42 Touch-up Paint Standard escription Package Quantity Number 12 3/4 oz. spray can of light gray enamel 1 TSP61 TSP uylog atalog ata subject to change

27 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Field Installed ccessories Filler Plates Standard escription Package Quantity Number 1/2 Filler Plate 100 TFH 1 Filler Plate 50 TQLFP1 overs 1/2 rectangular breaker knockouts overs 1 rectangular breaker knockouts TFH Universal Raintight Hubs Standard escription ase Size (in.) Package Quantity Number 3/4 iameter 3 10 T75 1 iameter 3 10 T /4 iameter 3 10 T /2 iameter 3 10 T150 2 iameter 3 10 T /2 iameter 3 10 T250 3 iameter 3 5 T300 losing ap 3 10 TP 2 iameter 4 TU27 2-1/2 iameter 4 TU28 3 iameter 4 TU30 3-1/2 iameter 4 TU35 4 iameter 4 TU over Plate 4 TUP 1 For 40 and 42 circuit units in R8 boxes only. T150 oor Handle Standard escription Package Quantity Number Replacement oor Handle Universal 1 TRL22 TRL22 PowerMark Gold ross rm Standard escription Package Quantity Number Replacement cross arm for PowerMark Gold load centers 1 LROSSRM LROSSRM ata subject to change uylog atalog 1-27

28 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Field Installed ccessories PowerMark Gold Main reaker Retainers escription reaker Type Number Travel Trailer Main reaker Retainer it THQP THQPS for THQP reakers For use on PowerMark Plus load centers with THQL THQLR THQL reakers 225 max For use with circuit PowerMark Gold THQL THQLR1 load centers with THQL reakers For use with 6-8 circuit PowerMark Gold THQL THQLR2 load centers with THQL reakers For use with TM/TLM1212U Mod 2 current model THQL THQLR3 For use with 6-42 circuit PowerMark Gold THQL THQLR4 load centers with THQL reakers. Similar to THQLR1 but it does not take up a breaker space. For main lug load centers utilizing a back fed branch breaker as a main Handle Locks - Padlocking escription reaker Type Number THQP Padlocking Handle Lock THQP TQPPL THQL Padlocking Handle Lock THQL THP100 TQ Padlocking Handle Lock TQ TQPL1 Snap on handle lock Padlock not included THQLR THQLR1 THL103 Handle Locks - Non Padlocking escription reaker Type Number THQP Non Padlocking Handle Lock THQP TQPL THQL Non Padlocking Handle Lock THQL THL103 Snap on handle lock Handle Ties escription reaker Type Number Handle Ties for THQP reakers - Solid Snap-on THQP THT1 1 Trip Indicating Handle Ties for THQP reakers - For 2 THQPs THQP THT2 1 separated by 2 side-by-side THQPs TQ Snap-on Handle Tie - Trip Indicating TQ TQHT1 1 TQL TQ Snap-on Handle Tie - Solid TQ THT104 1 TQL TQ Multiwire ranch reaker TQ3HT 2 TQ Handle Tie its TQ4HT3 TQL ll multi-pole breakers have internal common trip Handle ties provide manual on-off capability only between one-pole devices 1 For two single-pole breakers 2 For three single-pole breakers - kit includes (10) pcs. 3 For four single-pole breakers - kit includes (10) pcs. THT1 THT104 THT2 TQHT uylog atalog ata subject to change

29 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Field Installed ccessories Load enter Hardware its Hardware Standard escription Package Quantity Number PowerMark Plus hardware kit: TQ THQ Main or 1 LHIT THL main lug kit in a TLM load center, installation instructions and front mounting screws Powermark Gold ond Screw it Screw TS Powermark Gold ond Screw it TS22 Powermark Gold Hardware kit 1 THWRIT containing 20 front mounting screws Powermark Gold Hardware kit 1 THWRIT2 containing 10 interior mounting screws Generator Interlock it Standard escription Package Quantity Number Load enter Generator Interlock it 1 THQLLX1 MSL Generator Interlock it 1 THQLLX4 MSL Generator Interlock it 1 THQLLX8U MSL Generator Interlock it 1 THQLLX8R MSL Generator Interlock it 1 THQLLX8FL PowerMark Gold uxiliary Gutter nclosures escription Number 24 uxiliary Gutter nclosure TMG24 28 uxiliary Gutter nclosure TMG28 28 uxiliary Gutter nclosure Flush TMG28F 33 uxiliary Gutter nclosure TMG33 39 uxiliary Gutter nclosure TMG39 43 uxiliary Gutter nclosure TMG43 43 eep uxiliary Gutter nclosure TMG43 PowerMark Gold Gutter Tap its escription Number 250 kcmil Lugs Gutter Tap it - one kit per phase required TMGT kcmil Lugs Gutter Tap it - one kit per phase required TMGT kcmil Lugs Gutter Tap it - one kit per phase required - TMGT750 Not for use with riser panels Meter Socket Load enter Flange its escription Semi-Flush it 400 for MSL Semi-Flush it 400 for MSL djustable Semi-Flush it 200 for MSL djustable Number SF400 SF400 SF200 Surge Protectors escription SurgePro 27 Panel-Mount Surge Protector Number THQLSURG ata subject to change uylog atalog 1-29

30 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams G G G reaker Fill reaker Symbol 1 THQL 1/2 THQP TL240SU, RU TL270SU, RU TL510RT Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G MIN LUGS TPL412, TL412, TPL412R, TL412R1, TL412R2, TL412R250GF, TL412R260GF T MIN LUGS TPL412T, TL412T TPL412RT, TL412RT1 F F F F F F MIN RR F MIN RR MIN RR SU F LUGS TLM612FU, SU FU, SU, RU TLM812FU, SU, FU, SU, RU TM815RUFL TM820RUFL TM860FUGN, TLM830FUGN, TM860SUGN, TLM830SUGN, TM860RUGN, TLM830RUGN MIN MIN TM1210U, TM1212U, TLM1212U TM1210RU, TM1212RU, TLM1212RU TLM2012URP MIN MIN F F MIN TLM1612U, TM1612U, TM1612RU TM1615U, TM1615RU, TM1620U, TLM1620U, TLM1620RU TLM812RU2 TM2420R uylog atalog ata subject to change

31 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams MIN MIN reaker Fill reaker Symbol 1 THQL 1/2 THQP Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G TM2010U, TM2010RU MIN TM2410U, TM2412U TM2412RU, TLM2412U, TLM2412RU TM2020U, TM2020RU TLM2020U, TLM2020RU MIN TM2415RU, TLM2415RU MIN MIN MIN MIN TLM242042, TM TM3210U TM3215U, TM3215RU TM3220U, TM3220RU, TLM3220U MIN MIN MIN MIN TM4020U, TM4020RU TLM4020U, TLM4020RU TM4222RU, TLM4222U TLM4222RU, TM4222U TM12410 TL12412 MIN TM321542, TLM322042, TM ata subject to change uylog atalog 1-31

32 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams reaker Fill reaker Symbol 1 THQL 1/2 THQP MIN MIN Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G TL18415, TL18420 TL24415, TM24415 MIN MIN MIN MIN MIN TL24440, TM24420 TM18410 TM30412 TM30415, TL30420, TM30240, TL uylog atalog ata subject to change

33 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams reaker Fill reaker Symbol 1 THQL 1/2 THQP Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G MIN MIN TL42420, TM42415, TM42420 TL42422 ata subject to change uylog atalog 1-33

34 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams reaker Fill reaker Symbol 1 THQL 1/2 THQP Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G MIN TM10RM, TM12RM, TM15RM, TM20RM, TSMR015SGP, TSMR020SGP TSL210SU, TSL210FU MIN Load Load TSL412SU TSL420SU, TSL420FU TSM415SU, TSM420SU, TSMF415SFL, TSMF420SFL, TSMR415SUGP, TSMR420SUGP, TSMR415SFLFMG, TSMR420SFLFMG SP PROVI FOR 110 PRLLL MIN RR MIN RR MIN RR MIN RR TSF420SU TSM1212SU, TSM1212FU TSM815SU, TSM820SU 1-34 uylog atalog ata subject to change

35 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams reaker Fill reaker Symbol 1 THQL 1/2 THQP Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G MIN RR MIN RR TSM1610SU, TSM1610FU, TSM1612FU, TSM1612SU TSM2020SU, TSM2020FU MIN RR MIN MIN Sub feed lugs MIN RR N TSM2420UF42 TSM815SFL, TSM820SFL, TSMF815SFL, TSMF820SFL, TSMR815SFLFMG, TSMR820SFLFMG TSM3220UWU PH NUTRL PH TSM3220USU, TSM3220UFU, TSM3222USU, TSM3222UFU MIN RR MIN RR MIN RR TSM4020UWU TSMR1212SU, TSM1212SU TSMR2020SU, TSMR2015SU, TSM2020SU, TSM2015SU TSLR420SU, TSLR412SU, TSL412SU, TSL420SU ata subject to change uylog atalog 1-35

36 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Wiring iagrams reaker Fill reaker Symbol 1 THQL 1/2 THQP Wire Range (WG/kcmil) Terminal Symbol u l o /0 12-1/0 6-2/0 6-2/ / F G Ground termination MIN L1 N L2 Space for Field-installed TQ reaker 200 Main reaker MIN RR PH PH TSMR2020SUFMG TM2440RMS, RMRS, RMS, TMH2440RMS, TMH2440RMRS NUTRL TSM2022USU, TSM2022UFU Space for Field-installed reaker Line L1 N L2 MIN MIN Neutral TS2432U42, TS2440U42 TSM2015URU Space for Field Installed Second Main reaker Space for Field Installed Second Main reaker Space for Field Installed Second Main reaker MIN MIN MIN TS032UFU TSR040UFU TSR840UFU 1-36 T uylog atalog ata subject to change

37 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Indoor nclosures nockouts Symbol F G H J L M N P Q R S T U V W X Y Z 5/16 3/8 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 onduit Size 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 inches /2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/ /2 3 1/2 3 1/2 4 imensions (in inches) ox No. Width Height epth / /4 3 3/ /2 9 7/32 3 5/ / / /8 3 3/ / / / /16 3 3/ /16 3 3/ /16 3 3/ /16 3 3/ /16 3 3/ /16 3 3/ /16 3 3/ /16 3 3/ /16 4 5/ /8 5 13/ /8 6 3/ /8 H H G G ox 1 J J H H X W ox 2 X W X X W G G H H Q H H Y H Q M F Q G Z Y M H Y H Y G Z ox 2 ox 3 ox 4, 6, 7, 8, 9, 11, 12, 13, 14 ox 4, 9 H S H S S N N ox 15 S S P J P J P P T ox 16 T P J G U V G J R P J G J ox 17 ox 18 ata subject to change uylog atalog 1-37

38 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Outdoor nclosures nockouts Symbol F G H J L M N P Q R S T U V W X Y Z 9/16 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 onduit Size 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 Inches /2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/ /2 3 1/2 3 1/2 3 1/2 4 4 imensions (in inches) ox No. Width Height epth R1 7 1/2 9 7/32 3 5/16 R1 7 1/ /4 R1 7 3/ /4 R2 11 1/4 11 1/8 3 1/4 R /2 5 R3 12 1/2 21 3/16 4 5/8 R / /16 5 1/4 R /16 4 5/8 R R5 12 1/ /16 4 5/8 R R /16 4 5/8 R / /16 5 1/4 R /16 4 5/8 R / /4 6 13/32 R /16 5 3/4 R / /32 R /16 6 7/8 R /16 6 7/8 R41 7 1/2 13 1/4 4 X W X W X ox R1 X W G HU ox R1 ox R2 Q R Q Q U R U Q H J ox R3, R5, R6 ox R3, R4, R5, R6, R7 ox R8 ox R4, R7 R L L J Mounting provided for universal hubs P T J R P G V U R J R8 ox R9 ox R10, R11 ox R uylog atalog ata subject to change

39 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Meter Socket Load enters nockouts Symbol F G H J L M N P Q R S T U V W X Y Z FF 5/32 3/8 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 onduit Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 inches /2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/ /2 3 1/2 3 1/2 3 1/2 4 4 imensions (in inches) ox No. Width Height epth R /2 4 7/8 R /4 5 3/4 R / /16 R / /16 R /4 34 1/4 7 5/16 R / /16 R /4 28 1/2 7 5/16 R /4 27 5/16 5 7/16 R / /8 7 3/16 R / /8 7 3/16 R / R / Y F Semi-Flush Only F W Q Semi-Flush Only HU PUNHING HU PUNHING F F F ox R12 F ox R14 G G ox R16 G ox R17, R18 Q G ox R19, R20 S Z S Z Z R S R S G R G R ox R21, R22 ox R23 ox R24 ata subject to change uylog atalog 1-39

40 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Meter Socket Load enters nockouts Symbol F G H J L M N P Q R S T U V W X Y Z FF 5/32 3/8 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 onduit Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 inches /2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/ /2 3 1/2 3 1/2 3 1/2 4 4 imensions (in inches) HU PUNHING HU PUNHING HU PUNHING HU PUNHING ox No. Width Height epth R /2 R / /8 6 3/16 R / /8 6 3/16 R /2 27 7/8 6 1/4 R /2 34 7/8 6 1/4 R / /2 6 3/16 R / /16 6 3/16 R R /8 18 9/16 5 R /2 Z Z Z S Z 1/4" S S ox R25 ox R26, R27 R L G G ox R28 ox R29 ox R30 HU PUNHING HU PUNHING R L G G FF FF ox R31 P P HU FF ox R32 FF ox R32 9/32 GG ox R uylog atalog ata subject to change

41 Load enters and ircuit reakers PowerMark Gold and Plus Load enters ircuit reakers Meter Socket Load enters nockouts Symbol F G H J L M N P Q R S T U V W X Y Z FF GG 5/32 3/8 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 onduit Size 1 1/4 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 in 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 inches /2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/ /2 3 1/2 3 1/2 3 1/2 4 4 imensions (in inches) ox No. Width Height epth R / /32 R / /32 R / /32 R /2 4 1/2 R /4 4 1/2 R /2 10 R /16 4 5/8 R /2 3/32 S S Z S 3/32 3/32 R R G S S Z S 3/32 3/32 R R G ox R33 ox R34, R35 HU HU HU HU 9/32 9/32 GG G G GG L W L ox R36, R37 ox R36, R37 ox R38 HU 9/32 9/32 d GG ox R39 ox R40 ata subject to change uylog atalog 1-41

42 Load enters and ircuit reakers NOTS: 1-42 uylog atalog ata subject to change

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution Table of Contents Introduction...2 Residential Power Distribution...4 Load Centers...6 Load Center Construction...8 Residential Circuit Breakers... 16 Ground Fault Protection...23 Arc Fault Protection...25

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

For Models #6-5001, #6-7501, #10-7501 & #10-12K1

For Models #6-5001, #6-7501, #10-7501 & #10-12K1 EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

Help protect your home, possessions and family.

Help protect your home, possessions and family. Help protect your home, possessions and family. A guide to your Square D electrical distribution system SM Make the most of your energy Understanding your home s electrical distribution system As one of

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

NEHB Panelboards Main Lugs and Main Circuit Breaker Replacement Parts

NEHB Panelboards Main Lugs and Main Circuit Breaker Replacement Parts NEH Panelboards Main Lugs and Main ircuit reaker Replacement Parts lass 1660 ONTENTS Schneider Electric rands Page Main Lugs and Main ircuit reaker225 Max............................ 2 Main Lugs600 Max.,

More information

Combination Starters. Class 8538/8539, 8738/8739

Combination Starters. Class 8538/8539, 8738/8739 ombination Starters lass 88/89, 878/879 ONTNTS Description Page General Information ombination Starters Rated pplication Data pproximate Dimensions and Shipping Weights.. 7 Panel Layout Drawings. Reversing

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if

More information

Miniature Circuit Breakers and Supplementary Protectors

Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG

More information

Engineers Edge, LLC PDH & Professional Training

Engineers Edge, LLC PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI)

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

Reverse-feed applications for circuit breakers

Reverse-feed applications for circuit breakers Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications..........................................................

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

Power Management Module 2. Installation

Power Management Module 2. Installation Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...

More information

Corner-Grounded Delta (Grounded B Phase) Systems

Corner-Grounded Delta (Grounded B Phase) Systems Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems

More information

Top Commercial / Residential Electrical Requirements *

Top Commercial / Residential Electrical Requirements * Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

6 Buck Boost Transformers

6 Buck Boost Transformers 6 uck oost Transformers uck-oost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

Sample - No Commercial Use

Sample - No Commercial Use COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

Requirements for Electrical Installations

Requirements for Electrical Installations ARTICLE 110 Requirements for Electrical Installations INTRODUCTION TO ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Article 110 sets the stage for how you ll implement the rest of the NEC. This

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

How To Test A Power Switch On A Power Supply

How To Test A Power Switch On A Power Supply transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability

More information

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS This guideline has been prepared to assist the owner/occupant of a single family dwelling with compliance to the requirements of the National Electrical

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system Table of Contents Introduction... 2 Distribution Systems... 4 Switchboard Definition... 9 Switchboard Construction... 12 Service Entrance Equipment... 18 Service Section... 20 Switchboard Grounding...

More information

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum

More information

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

Circuit Breaker. Description

Circuit Breaker. Description Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The

More information

Extension Cord Safety Policy

Extension Cord Safety Policy NATIONAL HIGH MAGNETIC FIELD LABORATORY Operated by Florida State University, University of Florida, Los Alamos National Laboratory Florida State University, 1800 East Paul Dirac Drive, Tallahassee, Florida

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W Centers Combination Catalog Number Logic Combination Sockets MC 30 40 B 1 00 S E C W ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L = Lug MB or

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure This sample chapter is for review purposes only. Copyright The Goodheart-Willcox Co., Inc. All rights reserved. 10 The Entrance Objectives Information in this chapter will enable you to: List the components

More information

Siemens STEP 2000 Course Basics of Electrical Products

Siemens STEP 2000 Course Basics of Electrical Products Siemens STEP 2000 Course Basics of Electrical Products It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Distribution Boards & Consumer Units

Distribution Boards & Consumer Units Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories

More information

Safety Switches. Section 4. www.geindustrial.com

Safety Switches. Section 4. www.geindustrial.com For more information on these products, order publications from Section 27. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 Heavy Duty, Type TH...4-7 Mill Duty, Type TH...4-14

More information

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22]

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22] [previous page #: 2-18; 2-22] Combination Logic Combination Sockets MC 30 40 B 1 200 S E C W 2 ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L =

More information

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited Electrical Wiring Methods, Components and Equipment for General Use Approved for Public Release; Further Dissemination Unlimited At the completion of this unit you shall be able to: 1. Utilize section

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov PHOTOVOLTAIC PERMITTING GUIDELINES The information provided in this document is general and is intended only as a

More information

Fusible Disconnect Switch

Fusible Disconnect Switch Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer 101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION Cutler-Hammer WELCOME Welcome to Module 3, Fundamentals of Electrical Distribution. If you have successfully completed Module

More information

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure Summary Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure This is a general procedure on how to replace Pathfinder 48-10kW shelf with a Cordex 3.6kW shelf. Part Numbers 010-567-20

More information

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com Temporary Power Outlet Panels Selection and Application Guide www.talonmetering.com 2012 Siemens Industry, Inc. www.talonmetering.com Talon meter mounting equipment For more than half a century, Talon

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 [email protected] Fax 804.355.8900 Page: 2 of 8 Quick

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches Features 15 3 2 20 9 11 16 17 1 18 6 19 13 5 SAFETY 8 1 12 7 1. Quick-make, quick-break operating mechanism that ensures positive operation. 2. Visible blade, double-break switching action. 3. Arc chutes

More information

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information