1 Fiberglass MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS The F312 disposable panel filters are designed to withstand the demands of tough industrial and commercial applications. Purolator assures filter durability by utilizing construction features not found in traditional designs. Frame -- Purolator F312 frames are produced using post consumer recycled materials. The unique Monobond pinch frame concept involves a one piece frame sealed to the media under heat and pressure. This construction feature produces a continuous bond of media to board around the periphery of the frame, eliminating weak corners and air bypass. The use of a high tensile strength polyethylene binder increases the integrity of the seal, allowing the filter to withstand varying temperatures and humidity levels. When compared to traditional designs, the filter s notched frame corners allow units to interlock, providing up to 33% savings on warehouse space and freight costs. Media -- Purolator F312 filters are manufactured with superior grade fiberglass media to guarantee full depth loading and high dust holding capacity. A computer controlled manufacturing process assures a uniform gradient density pattern in the media. To enhance filtration capability and prevent migration of finer particles, the filter media has a skin backing and is evenly coated with a gelled adhesive. Application -- Purolator s F312 filters perform best in conditions where large quantities of lint and dust are present. Their rugged construction makes them industry leaders in the high velocity system, pre-filter market. Performance is enhanced by a skin backing on the air leaving side of the media Space saving notched frame Reduce warehouse space and shipping costs with innovative Monobond pinch frame notched design Improved aerodynamics reduce restriction to air flow Safe, easy, fast installation Larger effective filtering surface area Wide selection of standard sizes Classified Class 2 by Underwriters Laboratories, Inc. 1

2 Fiberglass MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS Part Number Description Standard Sizes 1" Standard Sizes 2" Case Qty Weight F600-STD x 16 x 1 STD FG Disp Pnl M1-4 8 x 16 x F312-STD x 30 x 1 STD FG Disp Pnl M1-4 8 x 30 x F312-STD x 10 x 1 STD FG Disp Pnl M x 10 x F312-STD x 16 x 1 STD FG Disp Pnl M x 16 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 12 x 1 STD FG Disp Pnl M x 12 x F312-STD x 16 x 1 STD FG Disp Pnl M x 16 x F312-STD x 18 x 1 STD FG Disp Pnl M x 18 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 14 x 1 STD FG Disp Pnl M x 14 x F312-STD x 16 x 1 STD FG Disp Pnl M x 16 x F312-STD x 18 x 1 STD FG Disp Pnl M x 18 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 30-5/8 x 1 STD FG Disp Pnl M x 30-5/8 x F312-STD x 16 x 1 STD FG Disp Pnl M x 16 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 18 x 1 STD FG Disp Pnl M x 18 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 20 x 1 STD FG Disp Pnl M x 20 x F312-STD x 22-1/4 x 1 STD FG Disp Pnl M x 22-1/4 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 22 x 1 STD FG Disp Pnl M x 22 x F312-STD x 24 x 1 STD FG Disp Pnl M x 24 x F312-STD x 30 x 1 STD FG Disp Pnl M x 30 x F312-STD x 25 x 1 STD FG Disp Pnl M x 25 x F312-STD x 20 x 2 STD FG Disp Pnl M x 20 x F312-STD x 24 x 2 STD FG Disp Pnl M x 24 x F312-STD x 20 x 2 STD FG Disp Pnl M x 20 x F312-STD x 25 x 2 STD FG Disp Pnl M x 25 x F312-STD x 20 x 2 STD FG Disp Pnl M x 20 x F312-STD x 16 x 2 STD FG Disp Pnl M x 16 x F312-STD x 20 x 2 STD FG Disp Pnl M x 20 x F312-STD x 24 x 2 STD FG Disp Pnl M x 24 x F312-STD x 25 x 2 STD FG Disp Pnl M x 25 x F312-STD x 24 x 2 STD FG Disp Pnl M x 24 x F312-STD x 20 x 2 STD FG Disp Pnl M x 20 x F312-STD x 24 x 2 STD FG Disp Pnl M x 24 x F312-STD x 25 x 2 STD FG Disp Pnl M x 25 x F312-STD x 24 x 2 STD FG Disp Pnl M x 24 x F312-STD x 25 x 2 STD FG Disp Pnl M x 25 x

3 Fiberglass MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS Industrial Strength, 1" & 2" Disposable Panel Filters, Fiberglass Media Category F312 1" F312 2" Air Flow Velocity (FPM) Initial Resistance (In. W.G.).07".09" Recommended Final Resistance (In. W.G.).50" 1.0" Average Arrestance (%) 72% 75% * Resistance climbs more rapidly on 1" thus reducing dust holding capacity and filter life. Testing conducted in accordance with the ASHRAE Test Standard. Classified Class 2 by Underwriters Laboratories, Inc. 3

4 Polyester MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS Our long standing excellence in providing durable, top performing disposable filters is applied to the manufacturing of poly fiber P312 filters. Ideally suited for residential, commercial, or light industrial use, the polyester media was developed for situations where synthetic media products are required. Frame -- The P312 frame is produced using post consumer materials. The unique Monobond pinch frame concept involves a one piece frame sealed to the media under heat and pressure. This construction feature produces a continuous bond of media to board around the periphery of the frame, eliminating weak corners and air bypass. The use of a high tensile strength binder increases the integrity of the seal, allowing the filter to withstand varying temperatures and humidity levels. When compared to traditional designs, the filter s notched frame corners allow units to interlock, providing up to 33% savings on warehouse space and freight costs. Media -- The synthetic media used in a P312 consists of polyester filters bonded together in an interlocking pattern of tiny lint and dust traps. This configuration maximizes dust loading while minimizing resistance and surface loading. Application -- P312 filters perform best in conditions where large quantities of lint and dust are present. Their rugged construction makes them industry leaders in the high velocity system, pre-filter market. Space saving notched frame Reduce warehouse space and shipping costs with innovative Monobond pinch frame notched design Improved aerodynamics reduce restriction to air flow Safe, easy, fast installation Larger effective filtering surface area Wide selection of standard sizes Classified Class 2 by Underwriters Laboratories, Inc. 4

5 Polyester MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS Part Number Description Standard Sizes 1" Standard Sizes 2" Case Qty Weight P312-STD x 10 x 1 STD Syn Disp Pnl M x 10 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 12 x 1 STD Syn Disp Pnl M x 12 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 1 STD Syn Disp Pnl M x 25 x P312-STD x 30 x 1 STD Syn Disp Pnl M x 30 x P312-STD x 14 x 1 STD Syn Disp Pnl M x 14 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 1 STD Syn Disp Pnl M x 25 x P312-STD x 30 x 1 STD Syn Disp Pnl M x 30 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 16 x 1 STD Syn Disp Pnl M x 16 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 1 STD Syn Disp Pnl M x 25 x P312-STD x 18 x 1 STD Syn Disp Pnl M x 18 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 1 STD Syn Disp Pnl M x 25 x P312-STD x 20 x 1 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 1 STD Syn Disp Pnl M x 25 x P312-STD x 30 x 1 STD Syn Disp Pnl M x 30 x P312-STD x 24 x 1 STD Syn Disp Pnl M x 24 x P312-STD x 30 x 1 STD Syn Disp Pnl M x 30 x P312-STD x 25 x 1 STD Syn Disp Pnl M x 25 x P312-STD x 20 x 2 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 2 STD Syn Disp Pnl M x 24 x P312-STD x 20 x 2 STD Syn Disp Pnl M x 20 x P312-STD x 25 x 2 STD Syn Disp Pnl M x 25 x P312-STD x 20 x 2 STD Syn Disp Pnl M x 20 x P312-STD x 16 x 2 STD Syn Disp Pnl M x 16 x P312-STD x 20 x 2 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 2 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 2 STD Syn Disp Pnl M x 25 x P312-STD x 24 x 2 STD Syn Disp Pnl M x 24 x P312-STD x 20 x 2 STD Syn Disp Pnl M x 20 x P312-STD x 24 x 2 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 2 STD Syn Disp Pnl M x 25 x P312-STD x 24 x 2 STD Syn Disp Pnl M x 24 x P312-STD x 25 x 2 STD Syn Disp Pnl M x 25 x

6 Polyester MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS Industrial Strength, 1" & 2" Disposable Panel Filters, Synthetic Media Category P312 1" P312 2" Air Flow Velocity (FPM) Initial Resistance (In. W.G.).16".19" Recommended Final Resistance (In. W.G.).50" 1.00" Average Arrestance (%) 82% 89% * Testing conducted in accordance with the ASHRAE Test Standard. Classified Class 2 by Underwriters Laboratories, Inc. 6

7 Fiberglass and Synthetic MERV 5 Auto Rolls HVAC - AUTO ROLLS Automatic Roll Filters are designed for use in primary roll filter machines. These machines are self renewing, offering a new and clean section of air filter media either manually or automatically. Automatic Roll Filters are available for all machine types including: AAF -- Roll-O-Matic* Continental -- Conomatic or Conomanual* Cambridge Auto Roll* Carrier 31NA & 31NC Roll Filters* Farr -- Roll Kleen* Airmaze -- Roll-A-Maze* Trane Company Roll Filter* * Trade names are used for identification purposes only Automatic Roll Filters have been selected for use by industrial facilities, commercial buildings, government installations, schools and universities, and many other owners of automatic roll equipment. The Airguard replacement roll fits all existing requirements without modification, and filtration performance is guaranteed to equal or surpass original equipment. Fiberglass and Synthetic media for every application Fiberglass Media For years, the most popular of all air filter media, literally miles and miles of fiberglass strands reinforced with a thermosetting bonding agent, form this highly resilient blanket. Type CF -- Where the customer preference for economy is paramount, CF Media is made with a lighter weight fiber content. Type YTS -- YTS delivers more for the dollar spent in media. This media outperforms virtually all competitive roll filter media. It is recommended also where velocities are at 500 FPM and normal dirt conditions are present. Type SHP -- A specialty fiberglass media, this highly dense air filter blanket will perform under the most severe conditions. It is recommended where velocities are extreme and dirt loads are either very heavy or unpredictable. 7

8 HVAC - AUTO ROLLS Fiberglass and Synthetic MERV 5 Auto Rolls Synthetic Media For those customers preferring a synthetic air filter media, Airguard offers four styles. Constructed from high loft bulk fibers of post consumer recycled polyester fibers, synthetic media has increased steadily in popularity, particularly in the food, pharmaceutical, and electronic components industries. Type DSF (1/2") -- The most widely used synthetic auto roll media, the purchase price is approximately equal to comparable glass rolls. Recommended where air velocities are 500 FPM and dirt loads are normal. Type DMC (1") -- A specially designed, heavy weight polyester synthetic media, Type DMC is especially well suited for industrial applications, or other installations where airborne dirt is heavy. A fully lofted media furnished with a scrim net backing make this an appropriate choice for more extreme conditions. Type DL-I (1") -- This unique media is recommended where dirt loads are heavy and velocities are above normal. Type DL-1 delivers high dirt arrestance values. Type DL-II (2") -- This thick resilient blanket has the performance characteristics of high quality fiberglass with the advantages of a synthetic media. High dust holding and high arrestance characterize this media. Core Identification Guide Automatic Roll Filters Shown here are photos and brief descriptions of end views of various cores used on automatic roll filter machines. Airguard manufactures roll filter replacements for all machines, and this guide is offered for assistance in identifying the proper core when system identification is not possible through other means. All cores furnished are identical with those supplied by original equipment manufacturers. * Model No. indicates roll size and type. Media style is then designated with an additional suffix. Type AE Core (to fit American Air Filter Roll-O-Matic). Core is 3/8" I.D. (1-1/8" O.D.) welded steel tube and metal discs. End plates of approximately 11" diameter are attached. Sizes and Core Identification Roll Width Model No.* Roll Width Model No.* 32-3/4" 3AE 22-1/4" 22AE 44-3/4" 4AE 24-7/8" 25AE 56-3/4" 5AE 31-7/8" 32AE 68-3/4" 6AE 38-1/2" 39AE 20-1/4" 21AE 39-7/8" 40AE Type CR Core (to fit Carrier Corporation Series 31NA Roll Filter). Core is formed from a 2-7/16" fiberboard tube. The tube contains a metal cup secured in each end and recessed to a depth of 1-1/2". The cup is stamped to form a 1-1/2" square opening. Sizes and Core Identification Series 31NA Series 31NC Roll Width Model No.* Roll Width Model No.* 26-1/4" 2CR 23-1/2" 24CR 37-1/4" 3CR 34-1/2" 35CR 47-1/4" 4CR 44" 44CR 47-1/4" 6CR 58" 58CR " 68CR 8

9 Fiberglass and Synthetic MERV 5 Auto Rolls Type B Core (to fit BLC Industries Automatic Roll Machine). Core is constructed from 1-1/2" diameter. EMT conduit, with 11" diameter end plates recessed in approximately 1-3/8" from end of core. Type CB Core (to fit Cambridge Autoroll). Core is 3/4" welded steel tube. No metal discs are used. (if desired, please specify). Type AM Core (to fit Airmaze Roll-A- Maze). Core is formed from fiberboard tube with 1-7/8" I.D. Tube has recessed cups secured in each end with a depth of 5/8". Cup is stamped to form a 1-1/2" x 3/4" rectangular slot. Type F Core (to fit Farr Co. Roll Kleen Filters). Core is formed from 2-1/8" I.D. fiberboard tube using no drive pins, cups or discs. Type C Core (to fit Continental Conomanual or Conomatic). Core is formed from 3-1/6" I.D. PVC tube. A drive pin is located 2-1/4" from one end of the tube only. No cups or discs are used HVAC - AUTO ROLLS Sizes and Core Identification Roll Width Model No.* 24-5/8" 10B 34-5/8" 11B 46-5/8" 12B 58-5/8" 13B 70-5/8" 14B Sizes and Core Identification Roll Width Model No.* 23 2CB 32 3CB 44 4CB 56 5CB 65 6CB 70 6HCB Sizes and Core Identification Roll Width Model No.* 20-1/2" 2AM 32-1/2" 3AM 44-1/2" 4AM 56-1/2" 5AM 68-1/2" 6AM Sizes and Core Identification Roll Width Model No.* Roll Width Model No.* 33" 3F 15" 18F 45" 4F 21" 20F 57" 5F 27" 26F 69" 6F 39" 36F 9" 12F 51" 46F Sizes and Core Identification Roll Width Model No.* Roll Width Model No.* 21-7/8" 2C 55-7/8" 5C 31-7/8" 3C 67-7/8" 6C 43-7/8" 4C 35-7/8" 36C Type T Core (to fit Trane Company Roll Filter). Core is formed from 2-7/16" I.D. fiberboard tube. The tube contains a metal cup secured in each end recessed to a depth of 1-1/2" square. Sizes and Core Identification Roll Width Model No.* Roll Width Model No.* 19-3/8" 3T 59-3/8" 41T 21-3/8" 6T 63-3/8" 50T 31-3/8" 8T 25-3/4" 26T 35-3/8" 12T 38-3/4" 38T 45-3/8" 31T 50-1/4" 51T 54-3/8" 35T 61-3/4" 61T 9

10 Foam Filter Media HVAC - POLYESTER AND FOAM BULK MEDIA 1/4", 1/2", 1" Thicknesses Washable for Repeated Use Withstands Wide Temperature Extremes Applications Widely used as a permanent washable filter in place of metal filters or disposable panel filters in HVAC equipment, including: Room Air conditioners Fan Coil Units Unit Ventilators Air Handling Units Built Up Filter Banks Washable for Repeated Use The media can be cleaned for re-use by vacuuming, flushing, washing in warm water and detergents, even steaming. Suitable for Difficult Operating Conditions Foam media can withstand wide temperature extremes from - 50 F to +250 F. It can be sterilized in boiling water or steam. The chemical make up of foam media is not adversely affected by water, soap, detergents, oils, solvents or greases at normal temperatures. Part Number Description Size (In.) Case Qty Weight AFS-STD x 20 x 1/2 STD Washable Foam 16 x 20 x 1/ AFS-STD x 25 x 1/2 STD Washable Foam 16 x 25 x 1/ AFS-STD x 20 x 1/2 STD Washable Foam 20 x 20 x 1/ AFS-STD x 25 x 1/2 STD Washable Foam 20 x 25 x 1/ AFS-STD x 24 x 1/2 STD Washable Foam 24 x 24 x 1/ AFS-STD x 20 x 1 STD Washable Foam 16 x 20 x AFS-STD x 25 x 1 STD Washable Foam 16 x 25 x AFS-STD x 20 x 1 STD Washable Foam 20 x 20 x AFS-STD x 25 x 1 STD Washable Foam 20 x 25 x AFS-STD x 24 x 1 STD Washable Foam 24 x 24 x AFS x 10ft x 1/4 STD Washable Foam 24 x 10ft x 1/4 1 1 AFS-25-1B 24 x 25ft x 1/4 STD Washable Foam 24 x 25ft x 1/4 1 2 AFS x 10ft x 1/4 STD Washable Foam 36 x 10ft x 1/4 1 2 AFS-25-2B 36 x 25ft x 1/4 STD Washable Foam 36 x 25ft x 1/4 1 3 AFS x 10ft x 1/2 STD Washable Foam 24 x 10ft x 1/2 1 3 AFS-26-1B 24 x 25ft x 1/2 STD Washable Foam 24 x 25ft x 1/2 1 4 AFS x 10ft x 1/2 STD Washable Foam 36 x 10ft x 1/2 1 3 AFS x 10ft x 1 STD Washable Foam 24 x 10ft x

11 HVAC - POLYESTER AND FOAM ROLLS AND PADS Streamline - Synthetic Air Filter Media Product Summary Media Thickness Color Media Construction Tac P-Series P-50 1/2" White Blended Dual Denier Light P-100 1" Blue/White Blended Dual Denier Light P-200 2" Orange Blended Dual Denier Light DL-Series DL-100 1" Orange Stratified Multi Denier Heavy DL-200 2" Orange Stratified Multi Denier Heavy Bio.Pure Antimicrobial Treated Media AM-50 1/2" Yellow Blended Dual Denier Light AM-100 1" Yellow Blended Dual Denier Light AM-200 2" Yellow Blended Dual Denier Light 11

12 HVAC - POLYESTER AND FOAM ROLLS AND PADS Streamline - Synthetic Air Filter Media P-Series Part Number Description Size (In.) Case Qty Weight (Lbs) P x 24 x 1/2 Streamline STD Syn Pad Light Tack White 12 x 24 x 1/ P x 20 x 1/2 Streamline STD Syn Pad Light Tack White 16 x 20 x 1/ P x 25 x 1/2 Streamline STD Syn Pad Light Tack White 16 x 25 x 1/ P x 20 x 1/2 Streamline STD Syn Pad Light Tack White 20 x 20 x 1/ P x 25 x 1/2 Streamline STD Syn Pad Light Tack White 20 x 25 x 1/ P x 24 x 1/2 Streamline STD Syn Pad Light Tack White 24 x 24 x 1/ P x 24 x 1 Streamline STD Syn Pad Light Tack Blue/White 12 x 24 x P x 20 x 1 Streamline STD Syn Pad Light Tack Blue/White 16 x 20 x P x 25 x 1 Streamline STD Syn Pad Light Tack Blue/White 16 x 25 x P x 20 x 1 Streamline STD Syn Pad Light Tack Blue/White 20 x 20 x P x 25 x 1 Streamline STD Syn Pad Light Tack Blue/White 20 x 25 x P x 24 x 1 Streamline STD Syn Pad Light Tack Blue/White 24 x 24 x P x 24 x 2 Streamline STD Syn Pad Light Tack Orange 12 x 24 x P x 20 x 2 Streamline STD Syn Pad Light Tack Orange 16 x 20 x P x 25 x 2 Streamline STD Syn Pad Light Tack Orange 16 x 25 x P x 20 x 2 Streamline STD Syn Pad Light Tack Orange 20 x 20 x P x 25 x 2 Streamline STD Syn Pad Light Tack Orange 20 x 25 x P x 24 x 2 Streamline STD Syn Pad Light Tack Orange 24 x 24 x P200S x 24 x 2 Streamline STD Syn Pad Light Tack Orange Scrim 12 x 24 x P200S x 20 x 2 Streamline STD Syn Pad Light Tack Orange Scrim 16 x 20 x P200S x 25 x 2 Streamline STD Syn Pad Light Tack Orange Scrim 16 x 25 x P200S x 20 x 2 Streamline STD Syn Pad Light Tack Orange Scrim 20 x 20 x P200S x 25 x 2 Streamline STD Syn Pad Light Tack Orange Scrim 20 x 25 x P200S x 24 x 2 Streamline STD Syn Pad Light Tack Orange Scrim 24 x 24 x P50-R07 7 x 135ft Streamline STD Syn RL Light Tack White 7 x 135ft P50-R08 8 x 135ft Streamline STD Syn RL Light Tack White 8 x 135ft P50-R09 9 x 135ft Streamline STD Syn RL Light Tack White 9 x 135ft P50-R10 10 x 135ft Streamline STD Syn RL Light Tack White 10 x 135ft P50-R12 12 x 135ft Streamline STD Syn RL Light Tack White 12 x 135ft P50-R14 14 x 135ft Streamline STD Syn RL Light Tack White 14 x 135ft P50-R16 16 x 135ft Streamline STD Syn RL Light Tack White 16 x 135ft P50-R20 20 x 135ft Streamline STD Syn RL Light Tack White 20 x 135ft P50-R24 24 x 135ft Streamline STD Syn RL Light Tack White 24 x 135ft P50-R25 25 x 135ft Streamline STD Syn RL Light Tack White 25 x 135ft P50-R30 30 x 135ft Streamline STD Syn RL Light Tack White 30 x 135ft P50-R36 36 x 135ft Streamline STD Syn RL Light Tack White 36 x 135ft P50-R40 40 x 135ft Streamline STD Syn RL Light Tack White 40 x 135ft P50-R48 48 x 135ft Streamline STD Syn RL Light Tack White 48 x 135ft P50-R60 60 x 135ft Streamline STD Syn RL Light Tack White 60 x 135ft P50-R72 72 x 135ft Streamline STD Syn RL Light Tack White 72 x 135ft P50-R85 85 x 135ft Streamline STD Syn RL Light Tack White 85 x 135ft P100-R08 8 x 90ft Streamline STD Syn RL Light Tack White 8 x 90ft P100-R10 10 x 90ft Streamline STD Syn RL Light Tack White 10 x 90ft P100-R12 12 x 90ft Streamline STD Syn RL Light Tack White 12 x 90ft P100-R16 16 x 90ft Streamline STD Syn RL Light Tack White 16 x 90ft P100-R20 20 x 90ft Streamline STD Syn RL Light Tack White 20 x 90ft P100-R24 24 x 90ft Streamline STD Syn RL Light Tack White 24 x 90ft P100-R25 25 x 90ft Streamline STD Syn RL Light Tack White 25 x 90ft P100-R30 30 x 90ft Streamline STD Syn RL Light Tack White 30 x 90ft P100-R36 36 x 90ft Streamline STD Syn RL Light Tack White 36 x 90ft P100-R40 40 x 90ft Streamline STD Syn RL Light Tack White 40 x 90ft P100-R48 48 x 90ft Streamline STD Syn RL Light Tack White 48 x 90ft P100-R60 60 x 90ft Streamline STD Syn RL Light Tack White 60 x 90ft P100-R72 72 x 90ft Streamline STD Syn RL Light Tack White 72 x 90ft P100-R85 85 x 90ft Streamline STD Syn RL Light Tack White 85 x 90ft P200-R16 16 x 60ft Streamline STD Syn RL Light Tack Orange 16 x 60ft P200-R20 20 x 60ft Streamline STD Syn RL Light Tack Orange 20 x 60ft P200-R24 24 x 60ft Streamline STD Syn RL Light Tack Orange 24 x 60ft P200-R25 25 x 60ft Streamline STD Syn RL Light Tack Orange 25 x 60ft P200-R30 30 x 60ft Streamline STD Syn RL Light Tack Orange 30 x 60ft P200-R36 36 x 60ft Streamline STD Syn RL Light Tack Orange 36 x 60ft P200-R40 40 x 60ft Streamline STD Syn RL Light Tack Orange 40 x 60ft P200-R48 48 x 60ft Streamline STD Syn RL Light Tack Orange 48 x 60ft P200-R60 60 x 60ft Streamline STD Syn RL Light Tack Orange 60 x 60ft

13 HVAC - POLYESTER AND FOAM ROLLS AND PADS Streamline - Synthetic Air Filter Media P-Series Part Number Description Size (In.) Case Qty Weight (Lbs) P200-R72 72 x 60ft Streamline STD Syn RL Light Tack Orange 72 x 60ft P200-R85 85 x 60ft Streamline STD Syn RL Light Tack Orange 85 x 60ft P200S-R16 16 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 16 x 60ft P200S-R20 20 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 20 x 60ft P200S-R24 24 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 24 x 60ft P200S-R25 25 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 25 x 60ft P200S-R30 30 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 30 x 60ft P200S-R36 36 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 36 x 60ft P200S-R40 40 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 40 x 60ft P200S-R48 48 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 48 x 60ft P200S-R60 60 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 60 x 60ft P200S-R72 72 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 72 x 60ft P200S-R85 85 x 60ft Streamline STD Syn RL Light Tack Orange Scrim 85 x 60ft DL-Series Part Number Description Size (In.) Case Qty Weight (Lbs) DL100S-R16 16 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 16 x 65ft DL100S-R20 20 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 20 x 65ft DL100S-R24 24 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 24 x 65ft DL100S-R25 25 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 25 x 65ft DL100S-R30 30 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 30 x 65ft DL100S-R36 36 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 36 x 65ft DL100S-R40 40 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 40 x 65ft DL100S-R48 48 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 48 x 65ft DL100S-R60 60 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 60 x 65ft DL100S-R69 69 x 65ft Streamline STD Syn RL Heavy Tack Orange Scrim 69 x 65ft DL200S-R16 16 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 16 x 45ft DL200S-R20 20 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 20 x 45ft DL200S-R24 24 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 24 x 45ft DL200S-R25 25 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 25 x 45ft DL200S-R30 30 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 30 x 45ft DL200S-R36 36 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 36 x 45ft DL200S-R40 40 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 40 x 45ft DL200S-R48 48 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 48 x 45ft DL200S-R60 60 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 60 x 45ft DL200S-R69 69 x 45ft Streamline STD Syn RL Heavy Tack Orange Scrim 69 x 45ft

14 HVAC - POLYESTER AND FOAM ROLLS AND PADS Streamline - Synthetic Air Filter Media Bio Pure Part Number Description Size (In.) Case Qty Weight (Lbs) AM50-R08 8 x 120ft BioPure STD Syn RL Light Tack Yellow AM 8 x 120ft AM50-R10 10 x 120ft BioPure STD Syn RL Light Tack Yellow AM 10 x 120ft AM50-R12 12 x 120ft BioPure STD Syn RL Light Tack Yellow AM 12 x 120ft AM50-R16 16 x 120ft BioPure STD Syn RL Light Tack Yellow AM 16 x 120ft AM50-R20 20 x 120ft BioPure STD Syn RL Light Tack Yellow AM 20 x 120ft AM50-R24 24 x 120ft BioPure STD Syn RL Light Tack Yellow AM 24 x 120ft AM50-R25 25 x 120ft BioPure STD Syn RL Light Tack Yellow AM 25 x 120ft AM50-R30 30 x 120ft BioPure STD Syn RL Light Tack Yellow AM 30 x 120ft AM50-R36 36 x 120ft BioPure STD Syn RL Light Tack Yellow AM 36 x 120ft AM50-R40 40 x 120ft BioPure STD Syn RL Light Tack Yellow AM 40 x 120ft AM50-R48 48 x 120ft BioPure STD Syn RL Light Tack Yellow AM 48 x 120ft AM50-R60 60 x 120ft BioPure STD Syn RL Light Tack Yellow AM 60 x 120ft AM50-R72 72 x 120ft BioPure STD Syn RL Light Tack Yellow AM 72 x 120ft AM50-R85 85 x 120ft BioPure STD Syn RL Light Tack Yellow AM 85 x 120ft AM100-R08 8 x 75ft BioPure STD Syn RL Light Tack Yellow AM 8 x 75ft AM100-R10 10 x 75ft BioPure STD Syn RL Light Tack Yellow AM 10 x 75ft AM100-R12 12 x 75ft BioPure STD Syn RL Light Tack Yellow AM 12 x 75ft AM100-R16 16 x 75ft BioPure STD Syn RL Light Tack Yellow AM 16 x 75ft AM100-R20 20 x 75ft BioPure STD Syn RL Light Tack Yellow AM 20 x 75ft AM100-R24 24 x 75ft BioPure STD Syn RL Light Tack Yellow AM 24 x 75ft AM100-R25 25 x 75ft BioPure STD Syn RL Light Tack Yellow AM 25 x 75ft AM100-R30 30 x 75ft BioPure STD Syn RL Light Tack Yellow AM 30 x 75ft AM100-R36 36 x 75ft BioPure STD Syn RL Light Tack Yellow AM 36 x 75ft AM100-R40 40 x 75ft BioPure STD Syn RL Light Tack Yellow AM 40 x 75ft AM100-R48 48 x 75ft BioPure STD Syn RL Light Tack Yellow AM 48 x 75ft AM100-R60 60 x 75ft BioPure STD Syn RL Light Tack Yellow AM 60 x 75ft AM100-R72 72 x 75ft BioPure STD Syn RL Light Tack Yellow AM 72 x 75ft AM100-R85 85 x 75ft BioPure STD Syn RL Light Tack Yellow AM 85 x 75ft AM200-R16 16 x 45ft BioPure STD Syn RL Light Tack Yellow AM 16 x 45ft AM200-R20 20 x 45ft BioPure STD Syn RL Light Tack Yellow AM 20 x 45ft AM200-R24 24 x 45ft BioPure STD Syn RL Light Tack Yellow AM 24 x 45ft AM200-R25 25 x 45ft BioPure STD Syn RL Light Tack Yellow AM 25 x 45ft AM200-R30 30 x 45ft BioPure STD Syn RL Light Tack Yellow AM 30 x 45ft AM200-R36 36 x 45ft BioPure STD Syn RL Light Tack Yellow AM 36 x 45ft AM200-R40 40 x 45ft BioPure STD Syn RL Light Tack Yellow AM 40 x 45ft AM200-R48 48 x 45ft BioPure STD Syn RL Light Tack Yellow AM 48 x 45ft AM200-R60 60 x 45ft BioPure STD Syn RL Light Tack Yellow AM 60 x 45ft AM200-R72 72 x 45ft BioPure STD Syn RL Light Tack Yellow AM 72 x 45ft AM200-R85 85 x 45ft BioPure STD Syn RL Light Tack Yellow AM 85 x 45ft Product Data Media Thickness Initial FPM (in W.G.) Average Arrestance P-Series P-50 1/2".12 85% P-100 1".16 86% P-200 2".20 88% DL-Series DL-100S 1".16 88% DL-200S 2".22 90% Bio Pure AM-50 1/2".12 85% AM-100 1".16 86% AM-200 2".20 88% * Performance data is based on the ASHRAE test method. Tolerances conform to ARI Standard Recommended Final Resistance 1/2" -.5" W.G. 1" - 1.0" W.G 2" - 1.0" W.G. Underwriters Laboratories, Inc. Classification All StreamLine and Bio Pure media are classified U.L. Class 2. Operating Temperature Limit Continuous F 14

15 HVAC - RING AND LINK PANEL FILTERS Activator 2 Ply MERV 6 & Activator 3 Ply MERV 7 Ring and Link Panel Filters Self-Sealing Eliminates Bypass Moisture Resistant Totally Unitized Assembly Fast, Easy Installation No Latches Required Compact Packaging 15

16 HVAC - RING AND LINK PANEL FILTERS Activator 2 Ply MERV 6 & Activator 3 Ply MERV 7 Ring and Link Panel Filters Rated Air Flow Capacity (CFM) Part Number Ply Nominal Size ( In.) Actual Size of Internal Frame ( FPM ACT Ply 10 x /2 x 19-1/ ACT Ply 12 x /8 x 23-3/ ACT Ply 15 x /2 x 19-1/ ACT Ply 16 x /2 x 19-1/ ACT Ply 16 x /8 x 23-3/ ACT Ply 16 x /2 x 24-1/ ACT Ply 18 x /8 x 23-3/ ACT Ply 20 x /2 x 19-1/ ACT Ply 20 x /8 x 23-3/ ACT Ply 20 x /2 x 24-1/ ACT Ply 24 x /8 x 23-3/ ACT Ply 25 x /2 x 24-1/ ACT Ply 10 x /2 x 19-1/ ACT Ply 12 x /8 x 23-3/ ACT Ply 15 x /2 x 19-1/ ACT Ply 16 x /2 x 19-1/ ACT Ply 16 x /8 x 23-3/ ACT Ply 16 x /2 x 24-1/ ACT Ply 18 x /8 x 23-3/ ACT Ply 20 x /2 x 19-1/ ACT Ply 20 x /8 x 23-3/ ACT Ply 20 x /2 x 24-1/ ACT Ply 24 x /8 x 23-3/ ACT Ply 25 x /2 x 24-1/ All performance data is based on the ASHRAE 52.2 Test Standard 2. Width and height dimensions are interchangeable. Activator panels can be installed with the cross wires in the vertical or horizontal position. Continuous Operating Temperature Limit: 220 F (104 C) Underwriters Laboratories Classification: Activator panels are classified U.L. Class 2 per U.L. Standard 900. Class 1 panels are available. All 2-ply and 3-ply models are available as link panel filters Initial Resistance vs. Filter Face Velocity 16

17 HVAC - RING AND LINK PANEL FILTERS Series N MERV 6 Ring and Link Panel Filters Self-Sealing Eliminates Bypass Moisture Resistant Totally Unitized Assembly Fast, Easy Installation No Latches Required Compact Packaging The Series N panels, our most economical panel Product, are a 2-ply design consisting of a multi-denier, blended fiber pad on both sides with a heavy duty, 9 guage wire ring sealed inside. A dry tack adhesive applied on the air leaving side holds dirt and prevents particles from breaking loose. No particle migration down stream. Self Sealing, Leak-Free - Just push the filter into the frame. No clips, no latches, no leakage. Full Media Utilization - Series N filters have no perimeter frame or supporting grids to obstruct air flow and block off media. The entire face of the filter is exposed to the air stream. Rated Air Flow Capacity (CFM) Part Number Nominal Size ( In.) Actual Size of Internal Frame ( FPM IN x /2 x 19-1/ IN x /8 x 23-3/ IN x /2 x 19-1/ IN x /2 x 19-1/ IN x /8 x 23-3/ IN x /2 x 24-1/ IN x /8 x 23-3/ IN x /2 x 19-1/ IN x /8 x 23-3/ IN x /2 x 24-1/ IN x /8 x 23-3/ IN x /2 x 24-1/ All performance data is based on the ASHRAE Test Standard. Based on test velocity of 492 FPM for 24x24 face size. 2. Width and height dimensions are interchangeable. Activator panels can be installed with the cross wires in the vertical or horizontal position. Continuous Operating Temperature Limit: 220 F (104 C) Underwriters Laboratories Classification: Activator panels are classified U.L. Class 2 per U.L. Standard

18 HVAC - PLEATED AIR FILTERS Standard Capacity MERV 8 Self-Supported Pleated Air Filter MERV 8 High-Capacity Self-Supported Pleated Filters Standard-Capacity MERV 8, MERV-A 8-A New automated process delivers consistency and durability Durable, self-supporting synthetic media No metal, fully incinerable Die cut frame with interlocking corners for added strength 18

19 HVAC - PLEATED AIR FILTERS Standard Capacity MERV 8 Self-Supported Pleated Air Filter Rated Air Flow Capacity (CFM) Part Number Nominal Size2 Inches (W x H x D) Actual Size Inches (W x H x FPM Initial Resistance (In. W.G) Gross Media Area (Sq. Ft.) Standard KP-STD x 20 x 1 9-1/2 x 19-1/2 x 3/ KP-STD x 24 x 1 9-3/8 x 23-3/8 x 3/ KP-STD x 12 x /4 x 11-3/4 x 3/ KP-STD x 20 x /2 x 19-1/2 x 3/ KP-STD x 24 x /8 x 23-3/8 x 3/ KP-STD x 14 x /4 x 13-3/4 x 3/ KP-STD x 20 x /2 x 19-1/2 x 3/ KP-STD x 24 x /8 x 23-3/8 x 3/ KP-STD x 25 x /2 x 24-1/2 x 3/ KP-STD x 30 x /4 x 29-3/4 x 3/ KP-STD x 20 x /2 x 19-1/2 x 3/ KP-STD x 16 x /2 x 15-1/2 x 3/ KP-STD x 20 x /2 x 19-1/2 x 3/ KP-STD x 24 x /8 x 23-3/8 x 3/ KP-STD x 25 x /2 x 24-1/2 x 3/ KP-STD x 30 x /4 x 29-3/4 x 3/ KP-STD x 18 x /4 x 17-3/4 x 3/ KP-STD x 20 x /8 x 19-1/2 x 3/ KP-STD x 24 x /8 x 23-3/8 x 3/ KP-STD x 25 x /2 x 24-1/2 x 3/ KP-STD x 20 x /2 x 19-1/2 x 3/ KP-STD x 22 x /4 x 21-3/4 x 3/ KP-STD x 24 x /8 x 23-3/8 x 3/ KP-STD x 25 x /2 x 24-1/2 x 3/ KP-STD x 30 x /2 x 29-1/2 x 3/ KP-STD x 24 x /8 x 23-3/8 x 3/ KP-STD x 30 x /4 x 29-3/4 x 3/ KP-STD x 25 x /2 x 24-1/2 x 3/ KP-STD x 20 x 2 9-1/2 x 19-1/2 x 1-3/ KP-STD x 20 x /2 x 19-1/2 x 1-3/ KP-STD x 24 x /8 x 23-3/8 x 1-3/ KP-STD x 20 x /2 x 19-1/2 x 1-3/ KP-STD x 25 x /2 x 24-1/2 x 1-3/ KP-STD x 20 x /2 x 19-1/2 x 1-3/ KP-STD x 16 x /4 x 15-3/4 x 1-3/ KP-STD x 20 x /2 x 19-1/2 x 1-3/ KP-STD x 24 x /8 x 23-3/8 x 1-3/ KP-STD x 25 x /2 x 24-1/2 x 1-3/ KP-STD x 18 x /4 x 17-3/4 x 1-3/ KP-STD x 20 x /2 x 19-1/2 x 1-3/ KP-STD x 24 x /8 x 23-3/8 x 1-3/ KP-STD x 25 x /2 x 24-1/2 x 1-3/ KP-STD x 20 x /2 x 19-1/2 x 1-3/ KP-STD x 24 x /8 x 23-3/8 x 1-3/ KP-STD x 25 x /2 x 24-1/2 x 1-3/ KP-STD x 30 x /2 x 29-1/2 x 1-3/ KP-STD x 24 x /8 x 23-3/8 x 1-3/ KP-STD x 25 x /2 x 24-1/2 x 1-3/ NOTES: 1. MERV 8, MERV-A 8-A 2. All performance data is based on the ASHRAE Test Standard. Tested at 492 FPM for a 24x24x2 or 24x24x4 size filter. 3. Maximum final resistance 1.0" W.G. 4. Filters may be installed with the pleats either vertical (preferred) or horizontal. 5. Special sizes available upon request Underwriters Laboratories, Inc. Classification: Key Pleat filters are classified per U.L. 900 for flammability only. Operating Temperature Limits: Maximum operating temperature is 150 F (65 C). 19

20 HVAC - PLEATED AIR FILTERS Standard Capacity MERV 8 Self-Supported Pleated Air Filter Specifications 1.0 Scope This specification covers self supported-pleated panel filters that are a component of heating, ventilating and air conditioning systems. 2.0 Construction The filters shall consist of a self-supporting pleated media pack contained in a die cut beverage board frame. 2.1 Media The media shall consist of 100% synthetic fibers. 2.2 Media Pack The media shall be formed into uniformly shaped pleats with equal height measured from pleat apex to apex. The media pack shall be self-supporting, without the use of metal backing. The media pack shall maximize surface area to ensure adhesion with the stabilizer support straps and die cut diagonal support straps. [[ The media pack and die cut frame dimensions shall be equal to completely seal the pack inside the filter. The edges of the pack shall be roughed to allow complete adhesion to the frame. 2.3 Filter Frame The pleated media pack shall be contained in a frame made from a single-piece of die cut beverage board with high wet-strength characteristics. The die cut frame shall fully overlap around the entire perimeter of the filter. Diagonal support members shall provide support for the media pack on the air-leaving side. The die cut frame shall interlock in the corners, providing additional strength and rigidity. 2.4 Media Pack Adhesive The entire inside surface of the die cut frame shall be coated with a water-repellent adhesive to bond the pack inside the frame on all four edges. The pleat tips shall be bonded to the diagonal support members at all points of contact on the air-leaving side. The adhesive shall be water-repellent and maintain its bonding characteristics when wet. The adhesive shall not soften or dissolve when the filter is wet. 3.0 Performance 3.1 Filter Performance The filters shall meet the following minimum performance requirements based on the ASHRAE test standard. Testing shall be performed at 295 FPM on 1 filters and 492 FPM on 2 filters. 3.2 Maximum Operating Temperature The maximum operating temperature for the filter shall be 150 o F (65 o C). 3.3 Underwriters Laboratories Classification The filters shall be classified per U.L. Standard 900 for flammability only. P-KEYPLEAT

21 HVAC - PLEATED AIR FILTERS High Capacity MERV 8 Self-Supported Pleated Air Filter MERV 8 High-Capacity Self-Supported Pleated Filters High-Capacity MERV 8, MERV-A 8-A New automated process delivers consistency and durability Durable, self-supporting synthetic media No metal, fully incinerable Die cut frame with interlocking corners for added strength 21

22 HVAC - PLEATED AIR FILTERS High Capacity MERV 8 Self-Supported Pleated Air Filter Rated Air Flow Capacity (CFM) Part Number Nominal Size2 Inches (W x H x D) Actual Inches W x H x FPM Initial Resistance (In. W.G) Gross Media Area (Sq. Ft.) Standard KPH-STD x 20 x 1 9-1/2 x 19-1/2 x 3/ KPH-STD x 24 x 1 9-3/8 x 23-3/8 x 3/ KPH-STD x 12 x /4 x 11-3/4 x 3/ KPH-STD x 20 x /2 x 19-1/2 x 3/ KPH-STD x 24 x /8 x 23-3/8 x 3/ KPH-STD x 14 x /4 x 13-3/4 x 3/ KPH-STD x 20 x /2 x 19-1/2 x 3/ KPH-STD x 24 x /8 x 23-3/8 x 3/ KPH-STD x 25 x /2 x 24-1/2 x 3/ KPH-STD x 30 x /4 x 29-3/4 x 3/ KPH-STD x 20 x /2 x 19-1/2 x 3/ KPH-STD x 16 x /2 x 15-1/2 x 3/ KPH-STD x 20 x /2 x 19-1/2 x 3/ KPH-STD x 24 x /8 x 23-3/8 x 3/ KPH-STD x 25 x /2 x 24-1/2 x 3/ KPH-STD x 30 x /4 x 29-3/4 x 3/ KPH-STD x 18 x /4 x 17-3/4 x 3/ KPH-STD x 20 x /8 x 19-1/2 x 3/ KPH-STD x 24 x /8 x 23-3/8 x 3/ KPH-STD x 25 x /2 x 24-1/2 x 3/ KPH-STD x 20 x /2 x 19-1/2 x 3/ KPH-STD x 22 x /4 x 21-3/4 x 3/ KPH-STD x 24 x /8 x 23-3/8 x 3/ KPH-STD x 25 x /2 x 24-1/2 x 3/ KPH-STD x 30 x /2 x 29-1/2 x 3/ KPH-STD x 24 x /8 x 23-3/8 x 3/ KPH-STD x 30 x /4 x 29-3/4 x 3/ KPH-STD x 25 x /2 x 24-1/2 x 3/ KPH-STD x 20 x 2 9-1/2 x 19-1/2 x 1-3/ KPH-STD x 20 x /2 x 19-1/2 x 1-3/ KPH-STD x 24 x /8 x 23-3/8 x 1-3/ KPH-STD x 20 x /2 x 19-1/2 x 1-3/ KPH-STD x 25 x /2 x 24-1/2 x 1-3/ KPH-STD x 20 x /2 x 19-1/2 x 1-3/ KPH-STD x 16 x /4 x 15-3/4 x 1-3/ KPH-STD x 20 x /2 x 19-1/2 x 1-3/ KPH-STD x 24 x /8 x 23-3/8 x 1-3/ KPH-STD x 25 x /2 x 24-1/2 x 1-3/ KPH-STD x 18 x /4 x 17-3/4 x 1-3/ KPH-STD x 20 x /2 x 19-1/2 x 1-3/ KPH-STD x 24 x /8 x 23-3/8 x 1-3/ KPH-STD x 25 x /2 x 24-1/2 x 1-3/ KPH-STD x 20 x /2 x 19-1/2 x 1-3/ KPH-STD x 24 x /8 x 23-3/8 x 1-3/ KPH-STD x 25 x /2 x 24-1/2 x 1-3/ KPH-STD x 30 x /2 x 29-1/2 x 1-3/ KPH-STD x 24 x /8 x 23-3/8 x 1-3/ KPH-STD x 25 x /2 x 24-1/2 x 1-3/ KPH-STD x 24 x /8 x 23-3/8 x 3-3/ KPH-STD x 20 x /2 x 19-1/2 x 3-3/ KPH-STD x 25 x /2 x 24-1/2 x 3-3/ KPH-STD x 24 x /8 x 23-3/8 x 3-3/ KPH-STD x 20 x /2 x 19-1/2 x 3-3/ KPH-STD x 24 x /8 x 23-3/8 x 3-3/ KPH-STD x 25 x /2 x 24-1/2 x 3-3/ KPH-STD x 24 x /8 x 23-3/8 x 3-3/ NOTES: 1. MERV 8, MERV-A 8-A 2. All performance data is based on the ASHRAE Test Standard. Tested at 492 FPM for a 24x24x2 or 24x24x4 size filter. 3. Maximum final resistance 1.0" W.G. 4. Filters may be installed with the pleats either vertical (preferred) or horizontal. 5. Special Sizes Filters Available Upon Request 22

23 HVAC - PLEATED AIR FILTERS High Capacity MERV 8 Self-Supported Pleated Air Filter Underwriters Laboratories, Inc. Classification: Key Pleat filters are classified per U.L. 900 for flammability only. Operating Temperature Limits: Maximum operating temperature is 150 o F (65 o C Specifications 1.0 Scope This specification covers self supported-pleated panel filters that are a component of heating, ventilating and air conditioning systems. 2.0 Construction The filters shall consist of a self-supporting pleated media pack contained in a die cut beverage board frame. 2.1 Media The media shall consist of 100% synthetic fibers. 2.2 Media Pack The media shall be formed into uniformly shaped pleats with equal height measured from pleat apex to apex. The media pack shall be self-supporting, without the use of metal backing. The media pack shall maximize surface area to ensure adhesion with the stabilizer support straps and die cut diagonal support straps. [[ The media pack and die cut frame dimensions shall be equal to completely seal the pack inside the filter. The edges of the pack shall be roughed to allow complete adhesion to the frame. 2.3 Filter Frame The pleated media pack shall be contained in a frame made from a single-piece of die cut beverage board with high wet-strength characteristics. The die cut frame shall fully overlap around the entire perimeter of the filter. Diagonal support members shall provide support for the media pack on the air-leaving side. The die cut frame shall interlock in the corners, providing additional strength and rigidity. 2.4 Media Pack Adhesive The entire inside surface of the die cut frame shall be coated with a water-repellent adhesive to bond the pack inside the frame on all four edges. The pleat tips shall be bonded to the diagonal support members at all points of contact on the air-leaving side. The adhesive shall be water-repellent and maintain its bonding characteristics when wet. The adhesive shall not soften or dissolve when the filter is wet. 3.0 Performance 3.1 Filter Performance The filters shall meet the following minimum performance requirements based on the ASHRAE test standard. Testing shall be performed at 295 FPM on 1 filters and 492 FPM on 2 and 4" filters. 3.2 Maximum Operating Temperature The maximum operating temperature for the filter shall be 150 F (65 C). 3.3 Underwriters Laboratories Classification The filters shall be classified per U.L. Standard 900 for flammability only. P-KEYPLEATHC

24 Hi-E 40 Standard Capacity Wire Backed Pleated Air Filter HVAC - PLEATED AIR FILTERS 24

25 Hi-E 40 Standard Capacity Wire Backed Pleated Air Filter HVAC - PLEATED AIR FILTERS Part Number Nominal1 Size W x H x D Actual Size W x H x D CFM5 Capacity Resistance Inches W.G. Total Media Area/Filter HE40-STD x10x1 9-1/2 x 9-1/2 x 3/ HE40-STD x15x1 9-3/4 x 14-3/4 x 3/ HE40-STD x20x1 9-1/2 x 19-1/2 x 3/ HE40-STD x24x1 9-3/8 x 23-3/8 x 3/ HE40-STD x12x1 11-3/4 x 11-3/4 x 3/ HE40-STD x16x1 11-1/2 x 15-3/4 x 3/ HE40-STD x20x1 11-1/2 x 19-1/2 x 3/ HE40-STD x24x1 11-3/8 x 23-3/8 x 3/ HE40-STD x14x1 13-3/4 x 13-3/4 x 3/ HE40-STD x20x1 13-1/2 x 19-1/2 x 3/ HE40-STD x24x1 13-3/8 x 23-3/8 x 3/ HE40-STD x25x1 13-1/2 x 24-1/2 x 3/ HE40-STD x30x1* 13-3/4 x 29-3/4 x 3/ HE40-STD x20x1 14-1/2 x 19-1/2 x 3/ HE40-STD x30x1* 14-3/4 x 29-3/4 x 3/ HE40-STD x16x1 15-1/2 x 15-1/2 x 3/ HE40-STD x20x1 15-1/2 x 19-1/2 x 3/ HE40-STD x24x1 15-3/8 x 23-3/8 x 3/ HE40-STD x25x1 15-1/2 x 24-1/2 x 3/ HE40-STD x30x1* 15-3/4 x 29-3/4 x 3/ HE40-STD x18x1 17-3/4 x 17-3/4 x 3/ HE40-STD x20x1 17-3/8 x 19-1/2 x 3/ HE40-STD x22x1 17-3/8 x 21-1/2 x 3/ HE40-STD x24x1 17-1/2 x 23-3/8 x 3/ HE40-STD x25x1 17-1/2 x 24-1/2 x 3/ HE40-STD x20x1 19-1/2 x 19-1/2 x 3/ HE40-STD x22x1 19-3/4 x 21-3/4 x 3/ HE40-STD x24x1 19-3/8 x 23-3/8 x 3/ HE40-STD x25x1 19-1/2 x 24-1/2 x 3/ HE40-STD x30x1* 19-1/2 x 29-1/2 x 3/ HE40-STD x22x1 21-3/4 x 21-3/4 x 3/ HE40-STD x24x1 23-3/8 x 23-3/8 x 3/ HE40-STD x30x1* 23-3/4 x 29-3/4 x 3/ HE40-STD x25x1 24-1/2 x 24-1/2 x 3/ HE40-STD x20x2 9-1/2 x 19-1/2 x 1-3/ HE40-STD x12x2 11-3/4 x 11-3/4 x 1-3/ HE40-STD x20x2 11-1/2 x 19-1/2 x 1-3/ HE40-STD x24x2 11-3/8 x 23-3/8 x 1-3/ HE40-STD x20x2 13-1/2 x 19-1/2 x 1-3/ HE40-STD x25x2 13-1/2 x 24-1/2 x 1-3/ HE40-STD x20x2 14-1/2 x 19-1/2 x 1-3/ HE40-STD x16x2 15-3/4 x 15-3/4 x 1-3/ HE40-STD x20x2 15-1/2 x 19-1/2 x 1-3/ HE40-STD x24x2 15-3/8 x 23-3/8 x 1-3/ HE40-STD x25x2 15-1/2 x 24-1/2 x 1-3/ HE40-STD x18x2 17-3/4 x 17-3/4 x 1-3/ HE40-STD x20x2 17-1/2 x 19-1/2 x 1-3/ HE40-STD x22x2 17-1/2 x 21-1/2 x 1-3/ HE40-STD x24x2 17-3/8 x 23-3/8 x 1-3/ HE40-STD x25x2 17-1/2 x 24-1/2 x 1-3/ HE40-STD x20x2 19-1/2 x 19-1/2 x 1-3/ HE40-STD x24x2 19-3/8 x 23-3/8 x 1-3/ HE40-STD x25x2 19-1/2 x 24-1/2 x 1-3/ HE40-STD x30x2* 19-1/2 x 29-1/2 x 1-3/ HE40-STD x24x2 23-3/8 x 23-3/8 x 1-3/ HE40-STD x25x2 24-1/2 x 24-1/2 x 1-3/ HE40-STD x24x4 11-3/8 x 23-3/8 x 3-3/ HE40-STD x20x4 15-1/2 x 19-1/2 x 3-3/ HE40-STD x25x4 15-1/2 x 24-1/2 x 3-3/ HE40-STD x24x4 17-3/8 x 23-3/8 x 3-3/ HE40-STD x20x4 19-1/2 x 19-1/2 x 3-3/ HE40-STD x24x4 19-3/8 x 23-3/8 x 3-3/ HE40-STD X25X4 19-1/2 x 24-1/2 x 3-3/ HE40-STD X24X4 23-3/8 x 23-3/8 x 3-3/

26 Hi-E 40 Standard Capacity Wire Backed Pleated Air Filter HVAC - PLEATED AIR FILTERS * Reverse Pleat 1. Width and height dimensions are interchangeable. The Hi-E 40 may be installed with pleats vertical or horizontal. 2. Rated Efficiency: Hi-E 40 filters are rated MERV 8 per AHRAE Data based on 24x24 size atatest velocity of 295 or 492 FPM. 3. Hi-E 40 filters have a MERV 8 performance before and after a conditioning step. MERV-A 8-A per ASHRAE Appendix J. 4. Rated Air Velocity: FPM, 2" and FPM. 5. Final Resistance 1.0" W.G. 6. Special Sized Pleats Air Filters Available Upon Request. Underwriters Laboratories, Inc. Classification: Hi-E 40 filters are classified U.L. Class 2 per U.L. Standard 900. Operating Temperature Limit: Maximum operating temperature is 225 F (107 C). Pleat Count - 1" 2" 4" (Pleats per foot) Hi-E P-HIESTAND

27 DMK80 High Capacity MERV 8 Wire Backed Pleated Air Filter HVAC - PLEATED AIR FILTERS Defiant Mark 80-D TM 27

28 DMK80 High Capacity MERV 8 Wire Backed Pleated Air Filter HVAC - PLEATED AIR FILTERS Rated Air Flow Capacity (CFM) Part Number Nominal(1) Size W x H x D Actual Size W x H x FPM Resist. In W.G. High Total Media area/filter DMK80-STD x 10 x 1 9-1/2 x 9-1/2 x 3/ DMK80-STD x 15 x 1 9-3/4 x 14-3/4 x 3/ DMK80-STD x 20 x 1 9-1/2 x19-1/2 x 3/ DMK80-STD x 24 x 1 9-3/4 x 23-3/4 x 3/ DMK80-STD x 12 x /4 x 11-3/4 x 3/ DMK80-STD x 16 x /4 x 15-3/4 x 3/ DMK80-STD x 20 x /2 x 19-1/2 x 3/ DMK80-STD x 24 x /8 x 23-3/8 x 3/ DMK80-STD x 14 x /4 x 13-3/4 x 3/ DMK80-STD x 20 x /2 x 19-1/2 x 3/ DMK80-STD x 24 x /8 x 23-3/8 x 3/ DMK80-STD x 25 x /2 x 24-1/2 x 3/ DMK80-STD x 30 x /4 x 29-3/4 x 3/ DMK80-STD x 20 x /2 x 19-1/2 x 3/ DMK80-STD x 30 x /4 x 29-3/4 x 3/ DMK80-STD x 16 x /4 x 15-3/4 x 3/ DMK80-STD x 20 x /2 x 19-1/2 x 3/ DMK80-STD x 24 x /8 x 23-3/8 x 3/ DMK80-STD x 25 x /2 x 24-1/2 x 3/ DMK80-STD x 30 x /4 x 29-3/4 x 3/ DMK80-STD x 18 x /4 x 17-3/4 x 3/ DMK80-STD x 20 x /8 x 19-1/2 x 3/ DMK80-STD x 22 x /8 x 21-1/2 x 3/ DMK80-STD x 24 x /8 x 23-3/8 x 3/ DMK80-STD x 25 x /2 x 24-1/2 x 3/ DMK80-STD x 20 x /2 x 19-1/2 x 3/ DMK80-STD x 22 x /4 x 21-3/4 x 3/ DMK80-STD x 24 x /8 x 23-3/8 x 3/ DMK80-STD x 25 x /2 x 24-1/2 x 3/ DMK80-STD x 30 x /2 x 29-1/2 x 3/ DMK80-STD x 22 x /4 x 21-3/4 x 3/ DMK80-STD x 24 x /8 x 23-3/8 x 3/ DMK80-STD x 30 x /4 x 29-3/4 x 3/ DMK80-STD x 25 x /2 x 24-1/2 x 3/ DMK80-STD x 20 x 2 9-1/2 x19-1/2 x 1-3/ DMK80-STD x 12 x /4 x 11-3/4 x 1-3/ DMK80-STD x 20 x /2 x 19-1/2 x 1-3/ DMK80-STD x 24 x /8 x 23-3/8 x 1-3/ DMK80-STD x 20 x /2 x 19-1/2 x 1-3/ DMK80-STD x 25 x /2 x 24-1/2 x 1-3/ DMK80-STD x 20 x /2 x 19-1/2 x 1-3/ DMK80-STD x 16 x /4 x 15-3/4 x 1-3/ DMK80-STD x 20 x /2 x 19-1/2 x 1-3/ DMK80-STD x 24 x /8 x 23-3/8 x 1-3/ DMK80-STD x 25 x /2 x 24-1/2 x 1-3/ DMK80-STD x 18 x /4 x 17-3/4 x 1-3/ DMK80-STD x 20 x /2 x 19-1/2 x 1-3/ DMK80-STD x 22 x /2 x 21-1/2 x 1-3/ DMK80-STD x 24 x /8 x 23-3/8 x 1-3/ DMK80-STD x 25 x /2 x 24-1/2 x 1-3/ DMK80-STD x 20 x /2 x 19-1/2 x 1-3/ DMK80-STD x 24 x /8 x 23-3/8 x 1-3/ DMK80-STD x 25 x /2 x 24-1/2 x 1-3/ DMK80-STD x 30 x /4 x 29-1/2 x 1-3/ DMK80-STD x 24 x /8 x 23-3/8 x 1-3/ DMK80-STD x 25 x /2 x 24-1/2 x 1-3/ DMK80-STD x 24 x /8 x 23-3/8 x 3-3/ DMK80-STD x 20 x /2 x 19-1/2 x 3-3/ DMK80-STD x 25 x /2 x 24-1/2 x 3-3/ DMK80-STD x 24 x /8 x 23-3/8 x 3-3/ DMK80-STD x 20 x /2 x 19-1/2 x 3-3/ DMK80-STD x 24 x /8 x 23-3/8 x 3-3/ DMK80-STD x 25 x /2 x 24-1/2 x 3-3/

29 DMK80 High Capacity MERV 8 Wire Backed Pleated Air Filter HVAC - PLEATED AIR FILTERS Rated Air Flow Capacity (CFM) Part Number Nominal(1) Size W x H x D Actual Size W x H x FPM Resist. In W.G. High Total Media area/filter DMK80-STD x 24 x /8 x 23-3/8 x 3-3/ DMK80-STD x 29 x /2 x 24-1/2 x 3-3/ DMK80-STD x 30 x /2 x 27-1/2 x 3-3/ Width and height dimensions are interchangeable. The Defiant Mark 80-D may be installed with pleats running vertical or horizontal. 2. Rated Efficiency: Defiant Mark 80-D filters are rated MERV 8 per AHRAE Data based on 24x24 size at a test velocity of 295 or 492 FPM. 3. Defiant Mark 80-D filters have a MERV 8 performance before and after a conditioning step. MERV-A 8-A per ASHRAE Appendix J. 4. Rated Air Velocity: FPM, 2" and FPM. 5. Final Resistance 1.0" W.G. 6. Special Sized Filters Available Upon Request Underwriters Laboratories, Inc. Classification: Defiant Mark 80-D filters are classified U.L. Class 2 per U.L. Standard 900. Operating Temperature Limit: Maximum operating temperature is 225 o F (107 o C). Pleat Count - 1" 2" 4" (Pleats per foot) Defiant Mark 80-D P-DEFMARK

30 HVAC - PLEATED AIR FILTERS Electrostatically Enhanced MERV 11 Wire Backed Pleated Air Filter Introduction Purolator s PAF 11 filters are medium efficiency, self-supported, extended surface, pleated air filters. Specifically manufactured for system applications requiring high efficiency, non-shedding filtration media. Outperforms similar products with respect to initial efficiency, and average efficiency providing optimum filter service life. Effective in single filter applications or as improved pre-filter substitutes for disposables, permanent metal filters or media pad/frame filters. Industry applications: Pre-filtration for hospitals, health care facilities, food processing plants, telecommunications, pharmaceutical and semi-conductor manufacturing, etc. MERV 11 (Minimum Efficiency Reporting Value) based on ASHRAE Test Standard

31 HVAC - PLEATED AIR FILTERS Electrostatically Enhanced MERV 11 Wire Backed Pleated Air Filter Part Number Nominal Size W x H x D Actual Size W x H x D CFM(2) Resist Resist *W.G. Sq. Ft. Capacity *W.G. Final(3) PAF11-STD x 20 x 1 9-1/2 x 19-1/2 x 3/ PAF11-STD x 20 x /2 x 19-1/2 x 3/ PAF11-STD x 24 x /8 x 23-3/8 x 3/ PAF11-STD x 20 x /2 x 19-1/2 x 3/ PAF11-STD x 25 x /2 x 24-1/2 x 3/ PAF11-STD x 20 x /2 x 19-1/2 x 3/ PAF11-STD x 20 x /4 x 15-3/4 x 3/ PAF11-STD x 25 x /2 x 24-1/2 x 3/ PAF11-STD x 24 x /8 x 23-3/8 x 3/ PAF11-STD x 25 x /2 x 24-1/2 x 3/ PAF11-STD x 20 x /2 x 19-1/2 x 3/ PAF11-STD x 25 x /2 x 24-1/2 x 3/ PAF11-STD x 24 x /8 x 23-3/8 x 3/ PAF11-STD x 25 x /2 x 24-1/2 x 3/ PAF11-STD x 20 x 2 9-1/2 x 19-1/2 x 1-3/ PAF11-STD x 20 x /2 x 19-1/2 x 1-3/ PAF11-STD x 24 x /8 x 23-3/8 x 1-3/ PAF11-STD x 20 x /2 x 19-1/2 x 1-3/ PAF11-STD x 25 x /2 x 24-1/2 x 1-3/ PAF11-STD x 20 x /2 x 19-1/2 x 1-3/ PAF11-STD x 16 x /2 x 15-1/2 x 1-3/ PAF11-STD x 25 x /2 x 24-1/2 x 1-3/ PAF11-STD x 24 x /8 x 23-3/8 x 3-3/ PAF11-STD x 20 x /8 x 19-3/8 x 3-3/ PAF11-STD x 25 x /8 x 24-3/8 x 3-3/ PAF11-STD x 24 x /8 x 23-3/8 x 3-3/ PAF11-STD x 20 x /8 x 19-3/8 x 3-3/ PAF11-STD x 24 x /8 x 23-3/8 x 3-3/ PAF11-STD x 25 x /8 x 24-3/8 x 3-3/ PAF11-STD x 24 x /8 x 23-3/8 x 3-3/ PAF11-STD-25294(+) 25 x 29 x /2 x 28-1/2 x 3-3/ (*) = Reverse Pleat Construction (1) Width and height dimensions are interchangeable. The PAF 11 may be installed with pleats running vertical or horizontal. (2) Capacity ratings are recommended levels. Resistance to airflow data is based on ASHRAE Test Methods. Data based on 24x24 size at a test velocity of 492 FPM. (3) The recommended final operating resistance is typical of systems currently in operation. The PAF 11 can be operated to higher or lower final resistance levels without materially affecting filter efficiency. (4) The PAF 11 pleated filter is UL Class 2 approved and listed. Testing on this product was performed in accordance with UL Standard 900. Suggested operating temperatures: not to exceed 200 F (93 C). (5) Special sized filters available upon request P-PAF

32 HVAC - PLEATED AIR FILTERS High Capacity MERV 13 Wire Backed Pleated Air Filter MERV 13 Efficiency Performance for LEED Maintains MERV 13 Performance in a full ASHRAE independent test as required by LEED Meets LEED Green Building criteria for minimum efficiency Provides points toward LEED certification Achieves efficiency standards outlined in the LEED programs for Existing Buildings and New Construction 32

33 HVAC - PLEATED AIR FILTERS High Capacity MERV 13 Wire Backed Pleated Air Filter Part Number Nominal(1) Size W x H x D Actual Size W x H x D Rated Capacity (CFM) Initial Resistance (In. W.G.) Total Media area/filter PR13-STD x 10 x 1 9-1/2 x 9-1/2 x 3/ PR13-STD x 15 x 1 9-3/4 x 14-3/4 x 3/ PR13-STD x 20 x 1 9-1/2 x 19-1/2 x 3/ PR13-STD x 24 x 1 9-3/8 x 23-3/8 x 3/ PR13-STD x 12 x /4 x 11-3/4 x 3/ PR13-STD x 16 x /2 x 15-3/4 x 3/ PR13-STD x 20 x /2 x 19-1/2 x 3/ PR13-STD x 24 x /8 x 23-3/8 x 3/ PR13-STD x 14 x /4 x 13-3/4 x 3/ PR13-STD x 20 x /2 x 19-1/2 x 3/ PR13-STD x 24 x /8 x 23-3/8 x 3/ PR13-STD x 25 x /2 x 24-1/2 x 3/ PR13-STD x 30 x 1* 13-3/4 x 29-3/4 x 3/ PR13-STD x 20 x /2 x 19-1/2 x 3/ PR13-STD x 30 x 1* 14-3/4 x 29-3/4 x 3/ PR13-STD x 16 x /2 x 15-1/2 x 3/ PR13-STD x 20 x /2 x 19-1/2 x 3/ PR13-STD x 24 x /8 x 23-3/8 x 3/ PR13-STD x 25 x /2 x 24-1/2 x 3/ PR13-STD x 30 x 1* 15-3/4 x 29-3/4 x 3/ PR13-STD x 18 x /4 x 17-3/4 x 3/ PR13-STD x 20 x /8 x 19-1/2 x 3/ PR13-STD x 22 x /8 x 21-1/2 x 3/ PR13-STD x 24 x /8 x 23-3/8 x 3/ PR13-STD x 25 x /2 x 24-1/2 x 3/ PR13-STD x 20 x /2 x 19-1/2 x 3/ PR13-STD x 22 x /4 x 21-3/4 x 3/ PR13-STD x 24 x /8 x 23-3/8 x 3/ PR13-STD x 25 x /2 x 24-1/2 x 3/ PR13-STD x 22 x /4 x 21-3/4 x 3/ PR13-STD x 24 x /8 x 23-3/8 x 3/ PR13-STD x 30 x 1* 23-3/4 x 29-3/4 x 3/ PR13-STD x 25 x /2 x 24-1/2 x 3/ PR13-STD x 20 x /2 x 19-1/2 x 3/ PR13-STD x 20 x 2 9-1/2 x 19-1/2 x 1-3/ PR13-STD x 20 x /2 x 19-1/2 x 1-3/ PR13-STD x 24 x /8 x 23-3/8 x 1-3/ PR13-STD x 20 x /2 x 19-1/2 x 1-3/ PR13-STD x 25 x /2 x 24-1/2 x 1-3/ PR13-STD x 20 x /2 x 19-1/2 x 1-3/ PR13-STD x 20 x /2 x 19-1/2 x 1-3/ PR13-STD x 24 x /8 x 19-3/8 x 1-3/ PR13-STD x 25 x /2 x 24-1/2 x 1-3/ PR13-STD x 20 x /2 x 19-1/2 x 1-3/ PR13-STD x 24 x /8 x 23-3/8 x 1-3/ PR13-STD x 25 x /2 x 24-1/2 x 1-3/ PR13-STD x 20 x /2 x 19-1/2 x 1-3/ PR13-STD x 24 x /8 x 23-3/8 x 1-3/ PR13-STD x 25 x /2 x 24-1/2 x 1-3/ PR13-STD x 30 x 2 * 19-1/2 x 29-1/2 x 1-3/ PR13-STD x 24 x /8 x 23-3/8 x 1-3/ PR13-STD x 25 x2 24-1/2 x 24-1/2 x 1-3/ PR13-STD x 24 x /8 x 23-3/8 x 3-3/ PR13-STD x 20 x /2 x 19-1/2 x 3-3/ PR13-STD x 25 x /2 x 24-1/2 x 3-3/ PR13-STD x 24 x /8 x 23-3/8 x 3-3/ PR13-STD x 20 x /2 x 19-1/2 x 3-3/ PR13-STD x 24 x /8 x 23-3/8 x 3-3/ PR13-STD x 25 x /2 x 24-1/2 x 3-3/ PR13-STD x 24 x /8 x 23-3/8 x 3-3/

34 HVAC - PLEATED AIR FILTERS High Capacity MERV 13 Wire Backed Pleated Air Filter (*) = Reverse Pleat Construction 1. Puro-g13een filters have a MERV 13 Performance. All performance data is based on the Test Standards. Test data based on 24x24x2 Nominal Size at 492 FPM face velocity. 2. Filters may be installed with the pleats either vertical (preferred) or horizontal. 3. Puro-g13een filters are classified U.L. Class 2 per U.L. Standard Maximum operating temperature 200 o F. 5. Special Sized Pleats Available Upon Request. Sustainable Component for a LEED/Green Building Initiative. Meets LEED/Green requirement of MERV 13. (Leadership in Energy and Environment Design) P-PUROGREEN

35 HVAC - PLEATED AIR FILTERS High Temperature MERV 8 Aluminized Steel Frame Pleated Air Filter Introduction Purolator Air Filtration's Hi-E 40 H High Temperature filter is a medium efficiency pleated filter specially constructed for use in systems involving elevated operating temperatures. Media and Support The filter media is a special 1/4" thick, high density ultra-fine fiberglass reinforced by a woven fiberglass mesh. The wedge shaped pleats on Purolator s Hi-E 40H High Temperature filter are formed and supported using corrosion resistant, electro galvanized, expended steel. The filter media is bonded to the expanded metal to prevent media sagging or oscillation during operation. Operating temperature range: Constructed to operate at F continuously. Hi-E 40H is MERV 8 per ASHRAE As indicated by its name, the Hi-E 40H High Temperature filter is U.L. approved and tested. Testing on this product was performs in accordance with U.L. Standard 900 for Class 1 Filters. 35

36 HVAC - PLEATED AIR FILTERS High Temperature MERV 8 Aluminized Steel Frame Pleated Air Filter Construction Features The perimeter frame on the Purolator Hi-E 40H High Temperature filter is constructed of 24-gauge aluminized steel. The pleated element is supported downstream by a 24-gauge expanded aluminized steel face guard to ensure stability of the media pack at elevated temperatures. Suggested product Specifications 1. The filter shall be the Hi-E 40H High Temperature as manufactured by Purolator Air Filtration. 2. Air filters shall be (2 ), and (4 ) deep, medium efficiency, pleated media filter specifically constructed for elevated temperature conditions. 3. Air filter shall be constructed to operate at F continuously. 4. The filter media shall be 1/4 thick, high density ultra fine fiberglass reinforced by a woven fiberglass mesh. 5. The filter media shall be bonded to a corrosion resistant, expanded metal support grid with a 96% open face area. 6. The support grid shall be formed into a corrosion resistant, expanded metal support grid with a 96% open face area. 7. The support grid shall be formed into a wedge configuration to optimize use of the filter media. 8. The filter shall be U.L. approved and the tested. Testing shall be performed in accordance with U.L. Standard 900 For Class 1 Filters. CFM2 Capacity Resistance Inches W.G. Part Number Nominal Size W x H x D Actual Size W x H x D Medium High Medium High Final Media Area (Sq. Ft.) HE40H-STD x24x2 11-3/8x23-3/8x1-3/ HE40H-STD x20x2 15-1/2x19-1/2x1-3/ HE40H-STD x25x2 15-1/2x24-1/2x1-3/ HE40H-STD x20x2 19-1/2x19-1/2x1-3/ HE40H-STD x25x2 19-1/2x24-1/2x1-3/ HE40H-STD x24x2 23-3/8x23-3/8x1-3/ HE40H-STD x24x4 11-3/8x23-3/8x3-7/ HE40H-STD x20x4 15-1/2x19-1/2x3-7/ HE40H-STD x25x4 15-1/2x24-1/2x3-7/ HE40H-STD x20x4 19-1/2x19-1/2x3-7/ HE40H-STD x25x4 19-1/2x24-1/2x3-7/ HE40H-STD x24x4 23-3/8x23-3/8x3-7/ (1) Capacity ratings are recommended levels. Test data per ASHRAE , Based on the test velocity of the 492 FPM for 24x24x2 and 24x24x4 nominal filters. (2) The recommended final operating resistance is the typical of systems currently in operation. The Hi-E 40H can be operated to higher or lower final resistance level without materially affecting filter efficiency. P-HIE40CB

37 HVAC - PLEATED AIR FILTERS Standard Capacity Activated Carbon Self-Supported Pleated Air Filter Product features The goal of a Purolator Hi-E 40 CB pleated filter is to promote improved indoor air quality through odor control. These carbon-loaded pleated filters clean the air by removing airborne molecular contaminants present at levels less than one particle per million. Hi efficiency MERV 7: Small (20 x 50 mesh) carbon particles and pleated configuration maximize adsorbent surface area Low pressure drop: Uniform dispersion of carbon throughout media, not just on surface, lets air flow freely Longer filter life, minimal shedding/dusting: thermal bonding of media to carbon exposes maximum adsorbent surface area More adsorbent: pound for pound, our carbon media is six times more effective than competitive GAC carbons Applications The Purolator Hi-E 40 CB filter is recommended for typical IAQ settings of 1ppm or less. Specific applications include air conditioning filters, furnace filters, heating vents, air intakes, air purification devices, and ozone removal devices. Appropriate end users are those involved with filtration of hospital facilities, chemical plant offices/labs, pollution control areas, sewage disposal and waste management plant offices, airports, kitchens and restaurants, or commercial offices. Media A non-woven dual layer pleated filter media composed of synthetic fibers makes up the Hi-E 40 CB media. The media of the Hi-E 40 CB filter is so stiff with carbon that it is actually self-supporting, and requires no external wire reinforcements. The pre-filter layer is MERV 7, allowing for particulate and odor removal in one package. 37

38 HVAC - PLEATED AIR FILTERS Standard Capacity Activated Carbon Self-Supported Pleated Air Filter Each Hi-E 40 CB filter is loaded with 200 grams/sq. meter (GSM) of superior, 60% active, 20 x 50 mesh-size carbon particles. Our top-grade carbon provides six times the adsorbent surface area of standard GAC carbon, making it vastly more effective, efficient, and long-lasting. No adhesive is used in the media: Fine mesh carbon granules are bonded to the synthetic fibers by a unique thermal process that requires no adhesive, and blinds less than 1.5% of each carbon particle s effective surface area. As a result, more than 98.5% of the carbon s surface is exposed to contaminated air, resulting in maximum gas adsorbing capacity and efficiency. This bonding method also features minimal dust release. The pleated configuration of the Hi-E 40 CB media also increases the filter s exposed surface area, thereby providing a higher overall efficiency by expanding its capability to adsorb contaminants. Frame The Hi-E 40 CB filter elements are enclosed in a two-piece heavy duty, high-wet-strength beverage board frame. When assembled, the fully bonded double-wall frame combines with the integral corner flaps and forms a rugged, durable filter which will not rack, warp, or leak under normal operating conditions. Part Number Nominal Size W x H x D Actual Size W x H x D CFM2 Capacity Resistance Inches W.G. Media Area (Sq. Ft.) Carbon Weight (g) HE40CB-STD x 24 x /8 x 23-3/8 x 3/ HE40CB-STD x 20 x /2 x 19-1/2 x 3/ HE40CB-STD x 25 x /2 x 24-1/2 x 3/ HE40CB-STD x 20 x /2 x 19-1/2 x 3/ HE40CB-STD x 25 x /2 x 24-1/2 x 3/ HE40CB-STD x 24 x /8 x 23-3/8 x 3/ HE40CB-STD x 24 x /8 x 23-3/8 x 1-3/ HE40CB-STD x 20 x /2 x 19-1/2 x 1-3/ HE40CB-STD x 25 x /2 x 24-1/2 x 1-3/ HE40CB-STD x 20 x /2 x 19-1/2 x 1-3/ HE40CB-STD x 25 x /2 x 24-1/2 x 1-3/ HE40CB-STD x 24 x /8 x 23-3/8 x 1-3/ HE40CB-STD x 24 x /8 x 23-3/8 x 3-3/ HE40CB-STD x 20 x /2 x 19-1/2 x 3-3/ HE40CB-STD x 25 x /2 x 24-1/2 x 3-3/ HE40CB-STD x 20 x /2 x 19-1/2 x 3-3/ HE40CB-STD x 25 x /2 x 24-1/2 x 3-3/ HE40CB-STD x 24 x /8 x 23-3/8 x 3-3/ (1) Width and height dimensions are interchangeable. The Hi-E 40 CB may be installed with pleats running vertical or horizontal. (2) Capacity ratings are recommended levels. Resistance to airflow data is based on ASHRAE Test Method. Data based on a 24x24 at a test velocity of 492 FPM. (3) The recommended final operating resistance is typical of systems currently in operation. The Hi-E 40 CB can be operated to higher or lower final resistance levels without materially affecting filter efficiency. Suggested Product Specifications 1. The filter shall be the Hi-E 40 CB as manufactured by Purolator Air Filtration. 2. The filter shall have a MERV 7 pre-filter layer. 3. Air filters shall be (1 ), (2 ), and (4 ) deep pleated media, disposable panel type. 4. Pleat element shall be made with carbon element containing 200 grams/sq. meter (GSM). 5. To assure no dirty air bypass, the media grid assembly shall be bonded to all interior surfaces of the water resistant, diecut frame with solvent-free water based glue. 6. The support grid shall be formed into a wedge configuration to optimize use of the filter media. 7. To maintain accurate pleat alignment on 4 depth filters, die-cut diagonal frame members shall be bonded to the media pack upstream and downstream. 8. Suggested operating temperatures are not to exceed 200 F (93 C). P-HIE40CB

39 HVAC - EXTENDED SURFACE POCKET FILTERS Serva-Pak High Density Glass Extended Surface Pocket Filters High Density Glass Microfibers In Class 2 Configuration Up To MERV 14 Performance Corrosion-Resistant Galvanized Header Rigid Internal Support To calculate Gross media required use the following formula: Gross media area (sq. foot.) = {2 x [(# of pockets) x (pocket width*) x (pocket depth)]} 144 Example: SP = {2 x [(8 x 25 x 22)]} 144 = 61.1 Square feet *Pocket widths: 6- or 7-pocket = 26 ; 8- or 9-pocket = 25 ; 10-pocket=24.75 ; 12-pocket=24 Nominal Size W x H Actual Size W x H 24 x /8 x 23-3/8 20 x /8 x 23 3/8 20 x /8 x 19-3/8 12 x /8 x 23-3/8 Nominal and Actual Depths are 11, 19, 22, 26, and 30 Efficiency curve Media efficiency Series Rating Media Color Average Efficiency Thickness Average Arrestance MERV 40% Yellow 35-40%.15 95% -- 50% Tan 45-50%.25 95% -- 65% Orange 60-65%.25 97% 11 85% Red 80-85%.25 98% 12 95% Yellow 90-95%.25 99%

40 HVAC - EXTENDED SURFACE POCKET FILTERS Serva-Pak High Density Glass Extended Surface Pocket Filters Serva-Pak Model Number Designators Example: SP6512-C-U-M-4415 Serva-Pak, 60-65% Efficiency, Fiber Glass, 12 Pockets, Cambridge Style Header, Upstream Gasket, Oil Mist, 24x24x

41 HVAC - EXTENDED SURFACE POCKET FILTERS Serva-Pak Type S Synthetic Extended Surface Pocket Filters High Density Synthetic Microfibers In Class 2 Configuration MERV To MERV 14 Performance Corrosion-Resistant Galvanized Header Rigid Internal Support Full product description is: Model Number followed by the Size Example: SP x24x30 To calculate Gross media required use the following formula: Gross media area (sq. foot.) = {2 x [(# of pockets) x (pocket width*) x (pocket depth)]} 144 Example: SP95S = {2 x [(8 x 25 x 22)]} 144 = 61.1 Square feet *Pocket widths: 6- or 7-pocket = 26 ; 8- or 9-pocket = 25 ; 10-pocket=24.75 ; 12-pocket=24 Nominal Size W x H Actual Size W x H 24 x /8 x 23-3/8 20 x /8 x 23 3/8 20 x /8 x 19-3/8 12 x /8 x 23-3/8 Nominal and Actual Depths are 11, 19, 22, 26, and 30 Efficiency by Particle Size Standard Models (24x24 Sizes - Number of Pockets) Header Size Sizes (W x H) Number of Pockets (3-12) A 24x B 12x C 24x D 20x E 24x F 20x G 16x H 20x J 16x K 25x L 20x M 25x Min Depth: 10" Max Depth: 36" 41

42 HVAC - EXTENDED SURFACE POCKET FILTERS Serva-Pak Type S Synthetic Extended Surface Pocket Filters Media efficiency SERVA-PAK S Series Efficiency Rating Media Color Average Efficiency Average Arrestance MERV SP50S 50% White 50-55% 95% 10 SP65S 65% Orange 60-65% 97% 11 SP85S 85% Pink 80-85% 98% 13 SP95S 95% Yellow 90-95% 99% 14 Serva-Pak Model Number Designators Example: SP6512S-C-U-M-4415 Serva-Pak, 60-65% Efficiency, Synthetic, 12 Pockets, Cambridge Style Header, Upstream Gasket, Oil Mist, 24x24x

43 HVAC - EXTENDED SURFACE POCKET FILTERS Defiant Electrostatically Enhanced Extended Surface Pocket Filters Construction Features Unique stitch configuration for superior air flow and uniform media separation Double-lock stitching Pack secured by means of internal mechanical fasteners Continuous media-to-metal bonded construction Individual galvanized J-channel support frame Rigid media pockets allow for improved air flow and filter performance Frame Features: Corrosion resistant galvanized header, rigid internal support, and interlocking mitered corners 43

44 HVAC - EXTENDED SURFACE POCKET FILTERS Defiant Electrostatically Enhanced Extended Surface Pocket Filters Part Number Description Nominal Size Number Of Case Qty Weight Reorder QTY (W x H x D) Pockets D x 24 x 12 Defiant STD 70Eff 24 x 24 x D x 24 x 15 Defiant STD 70Eff 24 x 24 x D x 24 x 26 Defiant STD 70Eff 24 x 24 x D x 24 x 22 Defiant STD 70Eff 24 x 24 x D x 24 x 19 Defiant STD 70Eff 24 x 24 x D x 24 x 36 Defiant STD 70Eff 24 x 24 x D x 24 x 30 Defiant STD 70Eff 24 x 24 x D x 24 x 26 Defiant STD 70Eff 24 x 24 x D x 24 x 22 Defiant STD 70Eff 24 x 24 x D x 24 x 19 Defiant STD 70Eff 24 x 24 x D x 24 x 36 Defiant STD 70Eff 24 x 24 x D x 24 x 30 Defiant STD 70Eff 24 x 24 x D x 24 x 26 Defiant STD 70Eff 24 x 24 x D x 24 x 22 Defiant STD 70Eff 24 x 24 x D x 24 x 19 Defiant STD 70Eff 24 x 24 x D x 24 x 26 Defiant STD 70Eff 12 x 24 x D x 24 x 22 Defiant STD 70Eff 12 x 24 x D x 24 x 19 Defiant STD 70Eff 12 x 24 x D x 24 x 30 Defiant STD 70Eff 12 x 24 x D x 24 x 26 Defiant STD 70Eff 12 x 24 x D x 24 x 22 Defiant STD 70Eff 12 x 24 x D x 24 x 19 Defiant STD 70Eff 12 x 24 x D x 24 x 30 Defiant STD 70Eff 12 x 24 x D x 24 x 26 Defiant STD 70Eff 12 x 24 x D x 24 x 22 Defiant STD 70Eff 12 x 24 x D x 24 x 19 Defiant STD 70Eff 12 x 24 x D x 24 x 30 Defiant STD 70Eff 20 x 24 x D x 24 x 26 Defiant STD 70Eff 20 x 24 x D x 24 x 22 Defiant STD 70Eff 20 x 24 x D x 24 x 19 Defiant STD 70Eff 20 x 24 x D x 20 x 26 Defiant STD 70Eff 20 x 20 x D x 20 x 22 Defiant STD 70Eff 20 x 20 x D x 20 x 19 Defiant STD 70Eff 20 x 20 x D x 24 x 12 Defiant STD 85Eff 24 x 24 x D x 24 x 15 Defiant STD 85Eff 24 x 24 x D x 24 x 30 Defiant STD 85Eff 24 x 24 x D x 24 x 26 Defiant STD 85Eff 24 x 24 x D x 24 x 22 Defiant STD 85Eff 24 x 24 x D x 24 x 19 Defiant STD 85Eff 24 x 24 x D x 24 x 36 Defiant STD 85Eff 24 x 24 x D x 24 x 30 Defiant STD 85Eff 24 x 24 x D x 24 x 26 Defiant STD 85Eff 24 x 24 x D x 24 x 22 Defiant STD 85Eff 24 x 24 x D x 24 x 19 Defiant STD 85Eff 24 x 24 x D x 24 x 36 Defiant STD 85Eff 24 x 24 x D x 24 x 30 Defiant STD 85Eff 24 x 24 x D x 24 x 26 Defiant STD 85Eff 24 x 24 x D x 24 x 22 Defiant STD 85Eff 24 x 24 x D x 24 x 19 Defiant STD 85Eff 24 x 24 x D x 24 x 30 Defiant STD 85Eff 12 x 24 x D x 24 x 26 Defiant STD 85Eff 12 x 24 x D x 24 x 22 Defiant STD 85Eff 12 x 24 x D x 24 x 19 Defiant STD 85Eff 12 x 24 x D x 24 x 36 Defiant STD 85Eff 12 x 24 x D x 24 x 30 Defiant STD 85Eff 12 x 24 x D x 24 x 26 Defiant STD 85Eff 12 x 24 x D x 24 x 22 Defiant STD 85Eff 12 x 24 x D x 24 x 19 Defiant STD 85Eff 12 x 24 x D x 24 x 36 Defiant STD 85Eff 12 x 24 x D x 24 x 30 Defiant STD 85Eff 12 x 24 x D x 24 x 26 Defiant STD 85Eff 12 x 24 x D x 24 x 22 Defiant STD 85Eff 12 x 24 x D x 24 x 19 Defiant STD 85Eff 12 x 24 x D x 24 x 30 Defiant STD 85Eff 20 x 24 x D x 24 x 26 Defiant STD 85Eff 20 x 24 x

45 HVAC - EXTENDED SURFACE POCKET FILTERS Defiant Electrostatically Enhanced Extended Surface Pocket Filters Part Number Description Nominal Size Number Of Case Qty Weight Reorder QTY (W x H x D) Pockets D x 24 x 22 Defiant STD 85Eff 20 x 24 x D x 24 x 19 Defiant STD 85Eff 20 x 24 x D x 20 x 30 Defiant STD 85Eff 20 x 20 x D x 20 x 26 Defiant STD 85Eff 20 x 20 x D x 20 x 22 Defiant STD 85Eff 20 x 20 x D x 20 x 19 Defiant STD 85Eff 20 x 20 x D x 24 x 12 Defiant STD 95Eff 24 x 24 x D x 24 x 15 Defiant STD 95Eff 24 x 24 x D x 24 x 36 Defiant STD 95Eff 24 x 24 x D x 24 x 30 Defiant STD 95Eff 24 x 24 x D x 24 x 26 Defiant STD 95Eff 24 x 24 x D x 24 x 22 Defiant STD 95Eff 24 x 24 x D x 24 x 19 Defiant STD 95Eff 24 x 24 x D x 24 x 36 Defiant STD 95Eff 24 x 24 x D x 24 x 30 Defiant STD 95Eff 24 x 24 x D x 24 x 26 Defiant STD 95Eff 24 x 24 x D x 24 x 22 Defiant STD 95Eff 24 x 24 x D x 24 x 19 Defiant STD 95Eff 24 x 24 x D x 24 x 36 Defiant STD 95Eff 24 x 24 x D x 24 x 30 Defiant STD 95Eff 24 x 24 x D x 24 x 26 Defiant STD 95Eff 24 x 24 x D x 24 x 22 Defiant STD 95Eff 24 x 24 x D x 24 x 19 Defiant STD 95Eff 24 x 24 x D x 24 x 36 Defiant STD 95Eff 12 x 24 x D x 24 x 30 Defiant STD 95Eff 12 x 24 x D x 24 x 26 Defiant STD 95Eff 12 x 24 x D x 24 x 22 Defiant STD 95Eff 12 x 24 x D x 24 x 19 Defiant STD 95Eff 12 x 24 x D x 24 x 36 Defiant STD 95Eff 12 x 24 x D x 24 x 30 Defiant STD 95Eff 12 x 24 x D x 24 x 26 Defiant STD 95Eff 12 x 24 x D x 24 x 22 Defiant STD 95Eff 12 x 24 x D x 24 x 19 Defiant STD 95Eff 12 x 24 x D x 24 x 36 Defiant STD 95Eff 12 x 24 x D x 24 x 30 Defiant STD 95Eff 12 x 24 x D x 24 x 26 Defiant STD 95Eff 12 x 24 x D x 24 x 22 Defiant STD 95Eff 12 x 24 x D x 24 x 19 Defiant STD 95Eff 12 x 24 x D x 24 x 30 Defiant STD 95Eff 20 x 24 x D x 24 x 26 Defiant STD 95Eff 20 x 24 x D x 24 x 22 Defiant STD 95Eff 20 x 24 x D x 24 x 19 Defiant STD 95Eff 20 x 24 x D x 20 x 36 Defiant STD 95Eff 20 x 20 x D x 20 x 30 Defiant STD 95Eff 20 x 20 x D x 20 x 26 Defiant STD 95Eff 20 x 20 x D x 20 x 22 Defiant STD 95Eff 20 x 20 x D x 20 x 19 Defiant STD 95Eff 20 x 20 x

46 HVAC - EXTENDED SURFACE POCKET FILTERS Syn-Pak - 3 Ply 2, 3 & 4 Pocket MERV 8 Self Supported Pocket Filters Syn-Pak filters are widely used as the primary filters in the supply air system for paint spray booths. They are also used in HVAC air handling systems in hospitals, commercial and institutional buildings, educational facilities, industrial plants, pharmaceutical and food processing operations. The dual layer media design in a multi-pocket configuration results in a very high dust holding capacity for long service life. The filters are ideal for difficult operating conditions, such as turbulent air flow or heavy dirt loading. Two layer 100% polyester media Tackified media for high dust holding capacity Moisture resistant Works in front, rear or side access units Self-sealing design prevents bypass Classified U.L. Class 2 13/16" header option available Part Number Description Nominal Size In. Number Of Case Qty Weight Reorder QTY (W x H x D) Pockets SP x 24 x 15 Syn-Pak 200 STD M8 12 x 24 x SP x 20 x 15 Syn-Pak 200 STD M8 16 x 20 x SP x 24 x 15 Syn-Pak 200 STD M8 24 x 24 x SP x 20 x 15 Syn-Pak 300 STD M8 20 x 20 x SP x 24 x 15 Syn-Pak 300 STD M8 20 x 24 x SP x 24 x 15 Syn-Pak 300 STD M8 24 x 24 x SP x 24 x 15 Syn-Pak 400 STD M8 24 x 24 x Performance Data: Based on ASHRAE Test Standard Average Efficiency: 35-40%, MERV

47 HVAC - EXTENDED SURFACE POCKET FILTERS Ultra II - 2 & 3 Pocket MERV 8 Self Supported Pocket Filters Graduated Denier Media Construction Ultra II pocket filters are made with graduated denier polyester fibers. The upstream layer consists of larger fibers with a more open structure followed by a denser layer of finer fibers for greater depth loading, excellent dust holding capacity and longer life (fewer changeouts). The downstream layer is a needled media forming a final barrier to catch dirt particles. Self-Sealing - No Leakage The media is sewn around an internal wire support frame that forms a built in gasket. The filters are automatically sealed when installed to prevent leakage. No bypass. Self-Supported Pocket Construction The high loft polyester media holds its extended shape at all times, even with no air flow. No sagging or drooping. Tapered pocket shape prevents adjacent pockets from touching. Media is fully utilized, no blocking off. Pressure Sensitive Tack Holds Dirt The media has a heavy application of pressure sensitive tack to retain collected dirt particles. Fast, Easy Installation - Endorsed by Maintenance Personnel Worldwide Save on labor due to reduced changeout time. Simply push the filter into the frame or slide it into the track on side-access housings. No clips or latches are required. Primary Applications HVAC air handling systems and paint spray booth air intakes and exhaust. 47

48 HVAC - EXTENDED SURFACE POCKET FILTERS Ultra II - 2 & 3 Pocket MERV 8 Self Supported Pocket Filters Part Number Description Nominal Size In. Number Of Case Qty Weight Reorder QTY (W x H x D) Pockets 321 U2T3P x 24 x 20 Ultra II STD M8 24 x 24 x U2T2P x 25 x 12 Ultra II STD M8 20 x 25 x U2T1P x 24 x 15 Ultra II STD M8 12 x 24 x U2T2P x 20 x 15 Ultra II STD M8 20 x 20 x U2T2P x 24 x 15 Ultra II STD M8 20 x 24 x U2T2P x 25 x 15 Ultra II STD M8 20 x 25 x U2T2P x 24 x 15 Ultra II STD M8 24 x 24 x U2T3P x 24 x 15 Ultra II STD M8 24 x 24 x U2T1P x 24 x 20 Ultra II STD M8 12 x 24 x U2T2P x 20 x 20 Ultra II STD M8 20 x 20 x U2T2P x 25 x 20 Ultra II STD M8 20 x 25 x U2T2P x 24 x 20 Ultra II STD M8 24 x 24 x OSU3P x 24 x 20 Ultra II STD M8 20 x 24 x Efficiency - MERV 8 Performance (ASHRAE ). Data based on 24x24 and tested at 492 FPM 2. Actual size of the internal wire ring is 1/2" less than nominal. Operating Temperature Limits: Maximum operating temperature is 225 F (107 C) 48

49 HVAC - EXTENDED SURFACE RIGID CELL FILTERS DOMINATOR - Extended Surface Rigid Cell Filters 4" offered in MERV 11 & 14 and 12" offered in MERV 11 & 15 Unique Channel Flow Molded Media: 4" is MERV 11 & 14 and 12" is MERV 11 & 15 Class 1 per U.L. Standard 900 Very Low Resistance Reduces Energy Consumption; Lowers Energy Costs High Dust Holding Capacity Light Weight all Plastic Construction May qualify as a sustainable component for a LEED/Green Building Initiative 49

50 HVAC - EXTENDED SURFACE RIGID CELL FILTERS DOMINATOR - Extended Surface Rigid Cell Filters Part Number Description Nominal Size W x H x D Case Qty Weight Lead Time DR x 24 x 12 Dominator 95Eff Syn 24 x 24 x D DR x 24 x 12 Dominator 95Eff Syn 20 x 24 x D DR x 20 x 12 Dominator 95Eff Syn 20 x 20 x D DR x 24 x 12 Dominator 95Eff Syn 12 x 24 x D DR95B x 24 x 12 Dominator 95Eff Syn 24 x 24 x D DR95B x 24 x 12 Dominator 95Eff Syn 20 x 24 x D DR95B x 20 x 12 Dominator 95Eff Syn 20 x 20 x D DR95B x 24 x 12 Dominator 95Eff Syn 12 x 24 x D DR x 24 x 12 Dominator 65Eff Syn 24 x 24 x D DR x 24 x 12 Dominator 65Eff Syn 20 x 24 x D DR x 20 x 12 Dominator 65Eff Syn 20 x 20 x D DR x 24 x 12 Dominator 65Eff Syn 12 x 24 x D DR65B x 24 x 12 Dominator 65Eff Syn 24 x 24 x D DR65B x 24 x 12 Dominator 65Eff Syn 20 x 24 x D DR65B x 20 x 12 Dominator 65Eff Syn 20 x 20 x D DR65B x 24 x 12 Dominator 65Eff Syn 12 x 24 x D DR x 24 x 4 Dominator 95Eff Syn 24 x 24 x D DR x 25 x 4 Dominator 95Eff Syn 20 x 25 x D DR x 24 x 4 Dominator 95Eff Syn 20 x 24 x D DR x 20 x 4 Dominator 95Eff Syn 20 x 20 x D DR x 25 x 4 Dominator 95Eff Syn 16 x 25 x D DR x 20 x 4 Dominator 95Eff Syn 16 x 20 x D DR x 24 x 4 Dominator 95Eff Syn 12 x 24 x D DR95-H x 24 x 4 Dominator 95Eff Syn 24 x 24 x D DR95-H x 24 x 4 Dominator 95Eff Syn 20 x 24 x D DR95-H x 20 x 4 Dominator 95Eff Syn 20 x 20 x D DR95-H x 24 x 4 Dominator 95Eff Syn 12 x 24 x D DR x 24 x 4 Dominator 65Eff Syn 24 x 24 x D DR x 25 x 4 Dominator 65Eff Syn 20 x 25 x D DR x 24 x 4 Dominator 65Eff Syn 20 x 24 x D DR x 20 x 4 Dominator 65Eff Syn 20 x 20 x D DR x 25 x 4 Dominator 65Eff Syn 16 x 25 x D DR x 20 x 4 Dominator 65Eff Syn 16 x 20 x D DR x 24 x 4 Dominator 65Eff Syn 12 x 24 x D DR65-H x 24 x 4 Dominator 65Eff Syn 24 x 24 x D DR65-H x 24 x 4 Dominator 65Eff Syn 20 x 24 x D DR65-H x 20 x 4 Dominator 65Eff Syn 20 x 20 x D DR65-H x 24 x 4 Dominator 65Eff Syn 12 x 24 x D * Reverse size pleat on 25" height product. IMPORTANT NOTES: 1. All performance data is based on the ASHRAE 52.2 Test Standard 2. Width and height dimensions are interchangeable. DOMINATOR filters can be installed with the pleats vertical or horizontal 3. Continuous Operating Temperature 140 F (60 C). Underwriters Laboratories Inc. Classification: DOMINATOR filters are classified Class 1 per U.L. Standard 900. Energy Savings Calculator available online at LEED (Leadership in Energy and Environment Design) addresses all building types and emphasizes state-of-the-art strategies in five areas: sustainable site development, water savings, energy efficiency, materials and resources selection, and indoor environmental quality. For more information please visit:

51 HVAC - EXTENDED SURFACE RIGID CELL FILTERS AERO-CELL - Extended Surface Rigid Cell Filters AERO-CELL TM Fiberglass Filter Features: High Density, Ultra-Fine Glass Filter Media In Class 1 and Class 2 Configurations Up To MERV 14 Performance Corrosion-Resistant Galvanized Steel Rigid Internal Support Filtering Efficiencies Model Average Arrestance MERV Perf. Media Color 50 96% 10 Yellow 65 97% 11 Orange 85 98% 13 Pink 95 99% 14 Yellow 51

52 HVAC - EXTENDED SURFACE RIGID CELL FILTERS AERO-CELL - Extended Surface Rigid Cell Filters Part Number Description Nominal Size W x H x D Case Qty Weight Lead Time AC x 24 x 6 AeroCell 50Eff FG 12 x 24 x D AC x 20 x 6 AeroCell 50Eff FG 20 x 20 x D AC x 24 x 6 AeroCell 50Eff FG 20 x 24 x D AC x 24 x 6 AeroCell 50Eff FG 24 x 24 x D HAC x 24 x 6 AeroCell 50Eff FG 12 x 24 x D HAC x 24 x 6 AeroCell 50Eff FG 20 x 24 x D HAC x 24 x 6 AeroCell 50Eff FG 24 x 24 x D AC x 24 x 12 AeroCell 50Eff FG 12 x 24 x D AC x 20 x 12 AeroCell 50Eff FG 20 x 20 x D AC x 24 x 12 AeroCell 50Eff FG 20 x 24 x D AC x 24 x 12 AeroCell 50Eff FG 24 x 24 x D HAC x 24 x 12 AeroCell 50Eff FG 12 x 24 x D HAC x 20 x 12 AeroCell 50Eff FG 20 x 20 x D HAC x 24 x 12 AeroCell 50Eff FG 20 x 24 x D HAC x 24 x 12 AeroCell 50Eff FG 24 x 24 x D AC x 24 x 6 AeroCell 60Eff FG 12 x 24 x D AC x 24 x 6 AeroCell 60Eff FG 20 x 24 x D AC x 24 x 6 AeroCell 60Eff FG 24 x 24 x D HAC x 24 x 6 AeroCell 60Eff FG 12 x 24 x D HAC x 24 x 6 AeroCell 60Eff FG 20 x 24 x D HAC x 24 x 6 AeroCell 60Eff FG 24 x 24 x D AC x 24 x 12 AeroCell 60Eff FG 12 x 24 x D AC x 20 x 12 AeroCell 60Eff FG 20 x 20 x D AC x 24 x 12 AeroCell 60Eff FG 20 x 24 x D AC x 24 x 12 AeroCell 60Eff FG 24 x 24 x D HAC x 24 x 12 AeroCell 60Eff FG 12 x 24 x D HAC x 20 x 12 AeroCell 60Eff FG 20 x 20 x D HAC x 24 x 12 AeroCell 60Eff FG 20 x 24 x D HAC x 24 x 12 AeroCell 60Eff FG 24 x 24 x D AC x 24 x 6 AeroCell 85Eff FG 12 x 24 x D AC x 20 x 6 AeroCell 85Eff FG 20 x 20 x D AC x 24 x 6 AeroCell 85Eff FG 20 x 24 x D AC x 24 x 6 AeroCell 85Eff FG 24 x 24 x D HAC x 24 x 6 AeroCell 85Eff FG 12 x 24 x D HAC x 20 x 6 AeroCell 85Eff FG 20 x 20 x D HAC x 24 x 6 AeroCell 85Eff FG 20 x 24 x D HAC x 24 x 6 AeroCell 85Eff FG 24 x 24 x D AC x 24 x 12 AeroCell 85Eff FG 12 x 24 x D AC x 20 x 12 AeroCell 85Eff FG 20 x 20 x D AC x 24 x 12 AeroCell 85Eff FG 20 x 24 x D AC x 24 x 12 AeroCell 85Eff FG 24 x 24 x D HAC x 24 x 12 AeroCell 85Eff FG 12 x 24 x D HAC x 20 x 12 AeroCell 85Eff FG 20 x 20 x D HAC x 24 x 12 AeroCell 85Eff FG 20 x 24 x D HAC x 24 x 12 AeroCell 85Eff FG 24 x 24 x D AC x 24 x 6 AeroCell 95Eff FG 12 x 24 x D AC x 20 x 6 AeroCell 95Eff FG 20 x 20 x D AC x 24 x 6 AeroCell 95Eff FG 20 x 24 x D AC x 24 x 6 AeroCell 95Eff FG 24 x 24 x D HAC x 24 x 6 AeroCell 95Eff FG 12 x 24 x D HAC x 24 x 6 AeroCell 95Eff FG 20 x 24 x D HAC x 24 x 6 AeroCell 95Eff FG 24 x 24 x D AC x 24 x 12 AeroCell 95Eff FG 12 x 24 x D AC x 20 x 12 AeroCell 95Eff FG 20 x 20 x D AC x 24 x 12 AeroCell 95Eff FG 20 x 24 x D AC x 24 x 12 AeroCell 95Eff FG 24 x 24 x D HAC x 24 x 12 AeroCell 95Eff FG 12 x 24 x D HAC x 20 x 12 AeroCell 95Eff FG 20 x 20 x D HAC x 24 x 12 AeroCell 95Eff FG 20 x 24 x D HAC x 24 x 12 AeroCell 95Eff FG 24 x 24 x D * Standard Header is 3/4 ; a 1-1/8 header is available. The following non-standard size is available upon request: 20x20x12 Class 1 available where required. * Filters tested per ASHRAE standard Data based on 24x24x12 filters tested at 492 FPM. 52

53 HVAC - EXTENDED SURFACE RIGID CELL FILTERS AERO-CELL S - Extended Surface Rigid Cell Filters AERO-CELL TM S Synthetic Air Filter Features: Dual-Stage 100% Synthetic Fibers Class 2 U.L. Standard 900 Up To MERV 14 Performance Corrosion-Resistant Galvanized Steel Rigid Internal Support 53

54 HVAC - EXTENDED SURFACE RIGID CELL FILTERS AERO-CELL S - Extended Surface Rigid Cell Filters Standard Models Part Number Nominal Size W x H x D CFM Capacity Resist in w.g. Media area Sq. Ft. AC50S x 24 x AC50S x 24 x AC50S x 24 x AC50S x 24 x AC50S x 24 x AC50S x 24 x AC60S x 24 x AC60S x 24 x AC60S x 24 x AC60S x 24 x AC60S x 24 x AC60S x 24 x AC85S x 24 x AC85S x 24 x AC85S x 24 x AC85S x 24 x AC85S x 24 x AC85S x 24 x AC95S x 24 x AC95S x 24 x AC95S x 24 x AC95S x 24 x AC95S x 24 x AC95S x 24 x Headered Models* Part Number Nominal Size W x H x D Resist in w.g. Media area Sq. Ft. HAC50S x 24 x HAC50S x 24 x HAC50S x 24 x HAC50S x 24 x HAC50S x 24 x HAC60S x 24 x HAC60S x 24 x HAC60S x 24 x HAC60S x 24 x HAC60S x 24 x HAC60S x 24 x HAC85S x 24 x HAC85S x 24 x HAC85S x 24 x HAC85S x 24 x HAC85S x 24 x HAC85S x 24 x HAC95S x 24 x HAC95S x 24 x HAC95S x 24 x HAC95S x 24 x HAC95S x 24 x HAC95S x 24 x * Standard Header is 3/4 ; a 11/8 header is available. The following non-standard sizes are available upon request: 20x20x12 Dimensions: Standard or Headered Filter Models Size Width Height Depth 12 x /8 23 3/8 5 7/8 or 111/2 20 x /8 23 3/8 5 7/8 or 111/2 24 x /8 23 3/8 5 7/8 or 111/2 *Optional 11/8 header is available upon request 3/4 header is standard 54

55 HVAC - EXTENDED SURFACE RIGID CELL FILTERS AERO-CELL S - Extended Surface Rigid Cell Filters Headered Models* Filtering Efficiencies Model Merv Average Arrestance Media Color AC50S 10 36% White AC65S 11 97% Orange AC58S 13 98% Pink AC95S 14 99% Yellow Aero-Cell Model Number Designators Example AC95S-4412 Aero-Cell, No Header, 90-95% Efficiency, 24x24x12 P-DEFMARK

56 HVAC - EXTENDED SURFACE RIGID CELL FILTERS DEFIANT Cell - Extended Surface Rigid Cell Filters Standard Models Part Number Nominal Size W x H x D CFM Capacity Resist in w.g. Media Area Sq. Ft. MERV DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x DC x 24 x Headered Models* Part Number Nominal Size W x H x D Resist in w.g. Media Area Sq. Ft. MERV DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x DHC x 24 x * Filters tested per ASHRAE standard Data based on 24 x 24 x 12 filters tested at 492 FPM. 56

57 HVAC - EXTENDED SURFACE RIGID CELL FILTERS DEFIANT Cell - Extended Surface Rigid Cell Filters Headered Models* Defiant Cell Model Number Designators Example: DC Defiant Cell, No Header, 70-75% Efficiency, 24x24x6 P-DEFCELL

58 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell - Extended Surface Rigid Cell Filters Introduction The Purolator SERVA-cell is a high efficiency, extended surface, ASHRAE rated air filter. Its box filter construction eliminates the need for retainers and special external wire media supports. A high surface area to depth ratio provides the maximum amount of effective filter media in areas of minimum in-line duct space. MERV 11, 13 and 14 Recommended airflow rate: 500 FPM (625 FPM Max.) Applications: For conditions such as high humidity, turbulent airflow, intermittent water exposure, and elevated operating temperatures. Available in seven filter face sizes (see chart on back), and two depth sizes 6", 12". Part Number Nominal Size WxHxD Actual Size WxHxD Rated CFM Intial Resistance (In. W.G.) Media Area (Sq. Ft.) SL x 24 x /8 x 23-3/8 x 5-7/ SL x 20 x /8 x 19-3/8 x 5-7/ SL x 25 x /8 x 24-3/8 x 5-7/ SL x 20 x /8 x 19-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 25 x / x 24-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 20 x /8 x 19-3/8 x 11-1/ SL x 25 x /8 x 24-3/8 x 11-1/ SL x 20 x /8 x 19-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 25 x / x 24-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 20 x /8 x 19-3/8 x 5-7/ SL x 25 x /8 x 24-3/8 x 5-7/ SL x 20 x /8 x 19-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 25 x / x 24-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 20 x /8 x 19-3/8 x 11-1/ SL x 25 x /8 x 24-3/8 x 11-1/ SL x 20 x /8 x 19-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 25 x / x 24-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 20 x /8 x 19-3/8 x 5-7/ SL x 20 x /8 x 19-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 25 x / x 24-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 5-7/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 20 x /8 x 19-3/8 x 11-1/ SL x 25 x /8 x 24-3/8 x 11-1/ SL x 20 x /8 x 19-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 11-1/ SL x 25 x / x 24-3/8 x 11-1/ SL x 24 x /8 x 23-3/8 x 11-1/

59 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell - Extended Surface Rigid Cell Filters Serva-Cell Model Number Designators Example: SL95H7D-2412U Serva-Cell, 90-95% Efficiency, High Temp 750 Degrees, Double Header, 12x24x12, Upstream Gasket P-SERVA

60 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell 2VS - Extended Surface Rigid Cell Filters Featuring Dynamic Double-V Design All Plastic Construction 100% Synthetic Media Fully Incinerable Moisture Resistant Chemical Resistant Rigid Cell Design Low Resistance Light Weight U.L. Class LEED/Green Building Sustainable Component for a LEED/Green Building Initiative (Leadership in Energy and Environment Design) Exceeds LEED/Green requirement of MERV 13 Lower Energy Cost Part Number Nominal Size WxHxD Actual Size WxHxD Rated CFM Intial Resistance (In. W.G.) Media Area (Sq. Ft.) SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 20 x /8 x 19-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 20 x /8 x 19-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 24 x /8 x 23-3/8 x 11-1/ SL2VS x 20 x /8 x 19-3/8 x 11-1/

61 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell 2VS - Extended Surface Rigid Cell Filters 1. All performance data is based on the ASHRAE Test Standard. Data based on 24x24 size at a test velocity of 492 FPM. 2. Width and height dimensions are interchangeable. SERVA-CELL 2VS filters can be installed with the pleats vertical or horizontal 3. Continuous Operating Temperature: 140 F (60 C). Sustainable Component for a LEED/Green Building Initiative. Exceeds LEED/Green requirement of MERV 13. (Leadership in Energy and Environment Design) Underwriters Laboratories Inc. Classification: SERVA-CELL 2VS filters are classified Class 1 per U.L. Standard 900. Serva-Cell Model Number Designators Example: SL95H7D-2412U Serva-Cell, 90-95% Efficiency, High Temp 750 Degrees, Double Header, 12x24x12, Upstream Gasket P-2VS

62 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell VA - Extended Surface Rigid Cell Filters Introduction The Purolator SERVA-CELL VA offers the benefits of ASHRAE filtration performance, lightweight materials, and industrial strength construction able to withstand nominal airflow of 2500 CFM. Low pressure drop and maximum use of filtration surface area combine to increase filter service life and allow for maximum efficiency ratings. The SERVA CELL VA captures particulate in the size range of fine dust, soot, pollen, smoke bacteria, and vapor making it ideal for most air conditioning filter applications. Since they are self-contained and sized for most standard requirements, each SERVA CELL VA is maintenance free, and easy to replace (fits into most standard frames and housing). MERV 11, 13, 14, 16 and 95% DOP Available in three filter face sizes with a depth under 12 : 12 x 24, and 24 x 24. Available in 95% DOP efficiency. Initial Resistance Inches w.g. Part Number Nominal Size W x H x D Actual Size W x H x D CFM Standard High 625 Maximum Media area/sq.ft. 500 fpm fpm 750 fpm SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVA x 24 x /8 x 23-3/8 x 11-1/ SLVAP x 24 x /8 x 23-3/8 x 11-1/ N/A N/A 97 SLVAP x 24 x /8 x 23-3/8 x 11-1/ N/A N/A

63 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell VA - Extended Surface Rigid Cell Filters Serva-Cell Model Number Designators Example: SL95H7D-2412U Serva-Cell, 90-95% Efficiency, High Temp 750 Degrees, Double Header, 12x24x12, Upstream Gasket P-SERVA-VA

64 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell Full Box - Extended Surface Rigid Cell Filters Introduction Purolator s SERVA-CELL Full Box is a high efficiency, extended surface, ASHRAE rated air filter. Its Full Box design allows for increased surface area when compared to headered models. Its full box filter construction eliminates the need for retainers and special external wire media supports. A high surface area to depth ratio provides the maximum amount of effective filter media in areas of minimum inline duct space. Applications: For conditions such as high humidity, turbulent airflow, intermittent water exposure, and elevated operating temperatures < 350 F. Average efficiency range: 65-95% MERV 11-1 Average arrestance: 97-99% Recommended airflow rate: 500 FPM (625 FPM Max.) Available in seven filter face sizes (see chart on back), and two depth sizes----6", 12". Part Number Nominal Size W x H x D Actual Size W x H x D Rated CFM Intial Resistance (In. W.G.) Media Area (Sq. Ft.) Series SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 11 SLB x 20 x /8 x 19-3/8 x 5-7/ MERV 11 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 11 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 11 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 11 SLB x 20 x /8 x 19-3/8 x 11-1/ MERV 11 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 11 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 11 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 13 SLB x 20 x /8 x 19-3/8 x 5-7/ MERV 13 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 13 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 13 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 13 SLB x 20 x /8 x 19-3/8 x 11-1/ MERV 13 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 13 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 13 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 14 SLB x 20 x /8 x 19-3/8 x 5-7/ MERV 14 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 14 SLB x 24 x /8 x 23-3/8 x 5-7/ MERV 14 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 14 SLB x 20 x /8 x 19-3/8 x 11-1/ MERV 14 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 14 SLB x 24 x /8 x 23-3/8 x 11-1/ MERV 14 1 For full nominal size configuration, note exact size dimensions. Refer to list price schedule for exact size part number. 64

65 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell Full Box - Extended Surface Rigid Cell Filters Serva-Cell Model Number Designators Example: SL95H7D-2412U Serva-Cell, 90-95% Efficiency, High Temp 750 Degrees, Double Header, 12x24x12, Upstream Gasket P-SERVABOX

66 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell HighTemp- Extended Surface Rigid Cell Filters Introduction The Purolator SERVA-cell High Temp is a high efficiency, extended surface, ASHRAE rated air filter. Its box filter construction eliminates the need for retainers and special external wire media supports. A high surface area to depth ratio provides the maximum amount of effective filter media in areas of minimum in-line duct space. Applications: Specifically built for conditions such as turbulent airflow and elevated operating temperatures up to 750 F. Average efficiency range: 65-95% Average arrestance: 97-99% Recommended airflow rate: 500 FPM (625 FPM Max.) Available in seven filter face sizes (see chart on back), and two depth sizes----6", 12". Part Number Nominal Size W x H x D Actual Size W x H x D Rated CFM Intial Resistance (In. W.G.) Media Area (Sq. Ft.) Series SL65H x 24 x /8 x 23-3/8 x 11-1/ SL65H x 20 x /8 x 19-3/8 x 11-1/ SL65H x 24 x /8 x 23-3/8 x 11-1/ SL65H x 24 x /8 x 23-3/8 x 11-1/ SL85H x 24 x /8 x 23-3/8 x 11-1/ SL85H x 20 x /8 x 19-3/8 x 11-1/ SL85H x 24 x /8 x 23-3/8 x 11-1/ SL85H x 24 x /8 x 23-3/8 x 11-1/ SL95H x 24 x /8 x 23-3/8 x 11-1/ SL95H x 20 x /8 x 19-3/8 x 11-1/ SL95H x 24 x /8 x 23-3/8 x 11-1/ SL95H x 24 x /8 x 23-3/8 x 11-1/ * Actual Depth Dimension: Nominal depth 12 = Actual depth 111/2, Nominal depth 6 = Actual depth 57/8 66

67 HVAC - EXTENDED SURFACE RIGID CELL FILTERS Serva-Cell HighTemp- Extended Surface Rigid Cell Filters Serva-Cell Model Number Designators Example: SL95H7D-2412U Serva-Cell, 90-95% Efficiency, High Temp 750 Degrees, Double Header, 12x24x12, Upstream Gasket P-SERVAHIGHT

68 HVAC - GAS PHASE ADSORBER FILTERS Puro-Cell - Gas Phase Adsorber Filters Product Features The PURO CELL filter is a rigid box-type filter engineered to provide medium and high-efficiency filtration combined with odor control. Its construction eliminates the need for retainers and special external wire media supports. A high surface area-to-depth ratio provides the maximum amount of effective filter media in areas of minimum inline duct space. These carbon-loaded pleated box filters clean the air by removing airborne molecular contaminants present at levels less than one particle per million. High-efficiency: Small (20x50 mesh) carbon particles and pleated configuration maximize adsorbent surface area Low pressure drop: Uniform dispersion of carbon throughout media, not just on surface, lets air flow freely Longer filter life, minimal shedding/dusting: Thermal bonding of media to carbon exposes maximum adsorbent surface area More adsorbent: Pound for pound, our carbon media is six times more effective than competitive carbons Media Part Number Description Nominal Size Actual Size CFM Intial Area (Sq Ft) Weight (LBS) 500FPM (W.G.) PCG-2412 Rigid Cell Box 12 x 24 x /8 x 23-3/8 x 11-1/ PCG-4412 Rigid Cell Box 24 x 24 x /8 x 23-3/8 x 11-1/ PCHG-2412 Rigid Cell Hdr 12 x 24 x /8 x 23-3/8 x 11-1/ PCHG-4412 Rigid Cell Hdr 24 x 24 x /8 x 23-3/8 x 11-1/ PCFD-2412 Rigid Cell Box Formaldehyde 12 x 24 x /8 x 23-3/8 x 11-1/ PCFD-4412 Rigid Cell Box Formaldehyde 24 x 24 x /8 x 23-3/8 x 11-1/ PCHFD-2412 Rigid Cell Hdr Formaldehyde 12 x 24 x /8 x 23-3/8 x 11-1/ PCHFD-4412 Rigid Cell Hdr Formaldehyde 24 x 24 x /8 x 23-3/8 x 11-1/ PCA-2412 Rigid Cell Box Ammonia 12 x 24 x /8 x 23-3/8 x 11-1/ PCA-4412 Rigid Cell Box Ammonia 24 x 24 x /8 x 23-3/8 x 11-1/ PCHA-2412 Rigid Cell Hdr Ammonia 12 x 24 x /8 x 23-3/8 x 11-1/ PCHA-4412 Rigid Cell Hdr Ammonia 24 x 24 x /8 x 23-3/8 x 11-1/ PCAG-2412 Rigid Cell Box Acid/Gas 12 x 24 x /8 x 23-3/8 x 11-1/ PCAG-4412 Rigid Cell Box Acid/Gas 24 x 24 x /8 x 23-3/8 x 11-1/ PCHAG-2412 Rigid Cell Hdr Acid/Gas 12 x 24 x /8 x 23-3/8 x 11-1/ PCHAG-4412 Rigid Cell Hdr Acid/Gas 24 x 24 x /8 x 23-3/8 x 11-1/ Note: For product numbers please contact customer service. 68

69 HVAC - GAS PHASE ADSORBER FILTERS Puro-Cell - Gas Phase Adsorber Filters Puro-Cell Model Number Designators Example: PCHFD-2412-D Puro-Cell, Header, Formaldehyde, 12x24x12, Downstream Gasket P-PUROCELL

70 HVAC - GAS PHASE ADSORBER FILTERS Puro Seal Refillable Carbon Trays - Gas Phase Adsorber Filters Introduction Purolator's refillable carbon trays provide dual filtration of particulate and odor adsorption. They are available for vapor or liquid phase filtration. (See the Application Reference Information on the back page.) Each panel is designed for easy replacement of the carbon media, and is offered in both standard and custom sizes to accommodate a variety of system needs. Designed to fit into the Purolator PURO Seal CSA (Carbon Side Access) housing (See Brochure #AC-PDS M (1/02) for more information on the CSA housing.). Trays may be emptied or refilled at regional activation service locations. Information specific to your region will be provided upon purchase. Standard screen size: 24-gauge diamond expanded carbon steel (flattened) with Glidden Glid-Guard high solid epoxy 5430 Black coating. Standard depth: 3/4". Contact factory for custom sizes and other depths. Media A variety of media options are available for selection based on customer application/system requirements (See the Application Reference Information on the back page). Construction Features Available in a variety of frame materials, with the most common being cold rolled steel with a baked enamel finish, or C.R.S. tinplated. Epoxy coated and stainless steel trays optional. NOTE: This information has been gathered from standard reference materials and/or test procedures and is believed to be true and accurate. It is offered solely for your consideration and verification. None of the information presented shall be construed as constituting a warranty or representation, expressed, written, or implied, for which we assume legal responsibility or that the information or goods described is fit for any particular use either alone or in combination with other goods or processes, or that it's use does not conflict with existing patent rights. No license is granted to infringe on any patent rights or practice any patent inversion. Suggested product Specifications 1. The filter shall be the PURO Seal Refillable Carbon Trays as manufactured by Purolator Air Filtration. 2. Trays shall be (3/4") deep, activated carbon media filters. Standard face sizes shall be 23 3/8" x 23 3/8" x 3/4" or 23 3/8" x 11 7/8" x 3/4". 3. Each tray shall have a removable tab for easy carbon replacement. 4. Standard frame construction shall be 24-gauge noncoated galvaneal. Part Number Actual Size Type PSRC-23F23FM-VCO-G 23-3/8 x 23-3/8 x 3/4 Virgin Carbon w/galvanized frame construction PSRC-23F23FM-VPI-G 23-3/8 x 23-3/8 x 3/4 Virgin Carbon filled with Potassium Permanganate Impregnated Media w/galvanized frame construction PSRC-23F23FM-VIC-G 23-3/8 x 23-3/8 x 3/4 Virgin Carbon filled with a blend of carbon and Permanganate Impregnated Media w/galvanized frame construction PSRC-23F23FM-VZI-G 23-3/8 x 23-3/8 x 3/4 Virgin Carbon filled with Impregnated Carbon w/galvanized frame PSRC-23F11FM-VCO-G 23-3/8 x 11-3/8 x 3/4 Virgin Carbon w/galvanized frame construction PSRC-23F11FM-VPI-G 23-3/8 x 11-3/8 x 3/4 Virgin Carbon filled with Potassium Permanganate Impregnated Media w/galvanized frame construction PSRC-23F11FM-VIC-G 23-3/8 x 11-3/8 x 3/4 Virgin Carbon filled with a blend of carbon and Permanganate Impregnated Media w/galvanized frame construction PSRC-23F11FM-VZI-G 23-3/8 x 11-3/8 x 3/4 Virgin Carbon filled with Impregnated Carbon w/galvanized frame 70

71 HVAC - GAS PHASE ADSORBER FILTERS Puro Seal Refillable Carbon Trays - Gas Phase Adsorber Filters Application Reference Information: CONTAMINANT INDUSTRY/APPLICATION CARBON TYPE Vapor Phase Acid and reactive gases: Hydrogen sulfide, Chlorine, Fluorine Sulfur Dioxide, Bromine, Nitrogen Dioxide Ammonia & Amines Mercury Formaldehyde General odor oxidants and low molecular weight organics (ethylene, amyl acetate, butyl, ammine, Chloroform, nitrogen oxide) General air filtration for HVAC: Air pollution, odor control, tobacco smoke, diesel fumes Volatile organic compounds Liquid Phase Odor, color, taste Chlorine - Electronic component protection in pulp and paper mills, refineries, fossil fuel electrical plants - Odor control: Sewage treatment plants - Air purification museums, archives, storage facilities - Shooting ranges - Pet food Manufacturing - Fertilizer plants - Petrochemical plants - Livestock and veterinary facilities - Flue gases, Incinerator exhaust - Battery production - Hospitals, laboratories - Paneling & furniture mfg. - Cold storage-fruit - Plastics manufacturing - Chemical plants - Schools - Office buildings - Cafeterias - Soil vapor extraction - Air stripper exhaust - Automotive ELCS canisters - Emission control - Paint booths - Plastics Manufacturing - Potable water systems - High quality water - Fume hoods - Tobacco Processing - Mining - Laboratories - Fume hoods - Insulation mfg. - Hospitals - Airports - Correctional facilities - Emission control - Paint booths - Plastics Manufacturing - Emission control - Pharmaceutical - Beverage Production - Beverage production - Electronics industry CGL/C1 CGL/PA CGL/HG CGL/COH CGL/KMNZK6 CGL/GAC CGL/CCCCS CGL/ZK6 CGL/GAC CGL/CCCCS CGL/ZK6 CGU/GAC CGU/MR CG CGU/GAC CGU/GAC Pyrogens - Potable water systems CGU/GA VOCs, BOD, COD, NOMs (natural organic matter), PAHs (polynuclear aromatic hydrocarbons), Chloroform, Humic and Fulvic acids, Vinyl Chloride methylene, Tannic compounds Tramp oil, Heavy metals, Suspended and dissolved solids, BOD, COD, TOC, Fats - Wastewater treatment: Municipal, Industrial, Truck washes, Food processing, Tanneries, Juice Production, Meat packing and production - Plating operations - Truck and tanker washing CGL/OMC CGL/LP Primary metal mills CGL/OM2 Sam Series P-PUROTRAY

72 Ultra-Cell LR - Hepa Filters HVAC - HEPA FILTERS Gasket seal U.L. Class 2 Available in Metal and Plastic 72

73 Ultra-Cell LR - Hepa Filters Plastic Frame Single Header HVAC - HEPA FILTERS Part Number Model Code Nominal Size Actual Size CFM Intial Resistance (In. W.G.) 0.3 Micron Media Area (Sq. Ft.) UCLR-4412-PH-SA 24 x 24 x /8 x 23-3/8 x 11-1/ % UCLR-0412-PH-SA 20 x 24 x /8 x 19-3/8 x 11-1/ % UCLR-0012-PH-SA 20 x 20 x /8 x 19-3/8 x 11-1/ % UCLR-2412-PH-SA 12 x 24 x /8 x 11-3/8 x 11-1/ %+ 49 Plastic Box Style- Com Part Number Model Code Nominal Size Actual Size CFM Intial Resistance (In. W.G.) 0.3 Micron Media Area (Sq. Ft.) UCLR x 24 x /8 x 23-3/8 x 11-1/ %+ TBD UCLR x 24 x /8 x 19-3/8 x 11-1/ %+ TBD UCLR x 20 x /8 x 19-3/8 x 11-1/ %+ TBD UCLR x 24 x /8 x 11-3/8 x 11-1/ %+ TBD Metal Cell Box Style Part Number Model Code Nominal Size Actual Size CFM Intial Resistance (In. W.G.) 0.3 Micron Media Area (Sq. Ft.) UCLR-4412E-MC 24 x 24 x x 24 x 11-1/ % UCLR-4412-MC 24 x 24 x /8 x 23-3/8 x 11-1/ % UCLR-2412E-MC 12 x 24 x x 12 x 11-1/ % UCLR-2412-MC 12 x 24 x /8 x 11-3/8 x 11-1/ %+ 56 NOTES: 1. Standard final resistance 1.5" W.G. for typical HVAC systems. 2. Optimal final resistance is twice initial resistance to maximize energy savings. 3. Minimum operating temperature of -5 o F with a Maximum operating temperature of 160 o F (Plastic) and 180 o F (Metal) 4. Performance data per 3rd party independent testing. Potential Ultra-Cell LR Applications Include Hospitals and Acute-Care Centers Low and High-Rise Commercial Buildings Nursing Homes Schools and Universities Assisted-Living Facilities Federal, State and Municipal Buildings Day Surgery Centers Food Processing Facilities Museums and Theaters Corporate Headquarters Asbestos Abatement General Containment 73

74 v Ultra-Cell LR - Hepa Filters HVAC - HEPA FILTERS * Chart used with permission of the National Air Filtration Association (NAFA). Pre-filters Pre-filters are required when using the 99%-Plus efficiency (on 0.3 micron) Ultra-Cell LR to ensure performance and maximize service life. Pre-filters remove large particulate that can quickly blind a filter with the superior efficiency of the Ultra-Cell LR. Pre-filter efficiency of MERV 8, or higher, is recommended. Suggested Purolator pre-filters are: Hi-E40/DMK80 MERV 8 PAF 11 MERV 11 PURO g13een MERV 13 Ultra-Cell LR Model Number Designators Example: UCLR-0012-PH-SA Ultra-Cell LR, 20x20x12, Header, Plastic Frame, Side Access Gasket P-ULTRACELL-LR

75 Ultra-Cell - Hepa Filters HVAC - HEPA FILTERS High Efficiency Filters (HEPA) 3 Types of Filters: Gasket Seal - 95/99.97/99.99 High Temp Gasket Seal / CFM Fluid Seal / CFM Introduction Purolator s ULTRA-CELL is a high efficiency aluminum separator style HEPA filter designed for applications where increased air velocity is present and lower pressure drops are required. Applications: Manufactured for environments requiring 95% minimum efficiency on.3 micron particles, 99.97% efficiency on.3 micron, 99.99% efficiency on.3 micron, or % on.3 micron (scan tested to assure no leak shall exceed 0.01% of the upstream challenge). Filter efficiencies range: 95%, 99.97%, 99.99%, and % at 0.3 micron. Available in many filter face sizes (see chart on back). Available in two depth sizes for High Temp 5 7/8" and 11 1/2", and one depth size for gasket seal and fluid seal 11 1/2" 75

76 HVAC - HEPA FILTERS Ultra-Cell - Hepa Filters Ordering Information The design and construction of Purolator Filtration System modules are coded with an assembly part number, divided into sections consisting of the following information: U C G L V X B U G N U G U Type 2 Material Section 1: Type of Product UC = ULTRA-CELL UH = ULTRA-CELL High Capacity 3 Efficiency Section 2: Frame material FPB = Fire retardant particle board NPB = Non-fire retardant particle board FPW = Fire retardant plywood NPW = Non-fire retardant plywood SSO = Type 304 Stainless steel GLV = 16-gauge galvaneal 4 Filter Size 5 Sealant 6 Seal 7 Faceguard Section 6: Fluid Seal GND = Gasket/neoprene downstream GNB = Gasket/neoprene both sides GNU = Gasket/neoprene upstream GSD = Gasket/silicone downstream GSB = Gasket/silicone both sides GSU = Gasket/silicone upstream FSU = Fluid Seal Upstream FSD = Fluid Seal Downstream FCU = Fluid Seal upstream with clips for fluid seal housing FCD = Fluid seal downstream with clips for fluid seal housing 8 U.L. Section 3: Efficiency option 95 = 95% on.3 micron 97 = 99.97% eff. on.3 micron 99 = 99.99% eff. on.3 micron (scan tested) Section 4: Filter Size = 24 x 12 x 11 1/ = 24 x 24 x 11 1/ = 24 x 18 x 11 1/ = 24 x 30 x 11 1/2 Please note: When ordering HEPA filters all dimensions are exact = 24 x 24 x 5 7/ = 24 x 30 x 5 7/ = 24 x 36 x 5 7/ = 24 x 48 x 5 7/ = 24 x 12 x 5 7/8 Section 5: Frame Style Sealant XBU = X-Body/urethane sealant DTU = Double turn flange/urethane DTH = Double turn flange/silicone sealant Section 7: Faceguard Location 00 = No face guard GU = Galvanized upstream GD = Galvanized downstream GB = Galvanized both sides SU = Stainless steel upstream SD = Stainless steel downstream SB = Stainless steel both sides Section 8: U.L. Classification 09 = UL 900 required 05 = UL 586 required 00 = UL requirements not required ULTRA CELL HIGH CAPACITY & 99.9 ON.3 MICRON (FLUID SEAL) Note: For Part Number Information and Pricing, Please Contact Customer Service. Air Flow CFM P-ULTRACELL

77 Ultra-Cell V-Pleat - Hepa Filters HVAC - HEPA FILTERS Introduction Purolator's ULTRA-CELL V-Pleat is a high efficiency mini-pleat separator, fluid seal style filter, designed to operate at 500 FPM. Average initial resistance: 1.20" w.g. on a 24 x 24 x 11 1/2 Applications: Manufactured for environments requiring 99.97% or 99.99% efficiency on.3 micron particles. (Due to the design of the V-Pleat, it cannot be scan tested.) Available in 11 1/2" filter depth. Construction Features Frame: Anodized extruded aluminum. The media pack is bonded and secured to the frame with a urethane-based sealant. The filter pack is a minipleat design utilizing thermoplastic separators. Fluid seal type: PURO Gel urethane fluid seal for gel seal applications (see diagram). Maximum operating temperature: <155 F. Testing: All HEPA filters are tested in our state of the art testing facility. All ULTRA-CELL V-Pleat filters will be tested for pressure drop and efficiency testing. Media and Support Media: Continuous sheet of non-combustible, waterproof, microfiberglass. Pleat Configuration: Mini-Pleat. Pleat Support: Thermoplastic separator. Applications The ULTRA-CELL V-Pleat is an excellent choice where systems require lower resistance. They can be used in Purolator's HEPA housings, Bag-in/Bag-out housings, or PURO HEPA holding frames. Suggested Product Specifications 1. The ULTRA-CELL V-Pleat High Efficiency Particulate Air (HEPA) filter shall be manufactured by Purolator Air Filtration. 2. Air filters shall be constructed in a clean environment using the latest technology in filter pleating and testing techniques. 3. The filter pack shall be sealed to the filter frame using a urethane base sealant. Knife-edge penetration of PURO Gel urethane seal 77

78 [ Ultra-Cell V-Pleat - Hepa Filters Suggested Product Specifications 1. The ULTRA-CELL V-Pleat High Efficiency Particulate Air (HEPA) filter shall be manufactured by Purolator Air Filtration. 2. Air filters shall be constructed in a clean environment using the latest technology in filter pleating and testing techniques. 3. The filter pack shall be sealed to the filter frame using a urethane base sealant. 4. The filter media shall consist of a continuous sheet of pleated, non-combustible, waterproof, microfiberglass media. 5. A quality assurance program shall be in place to verify pressure drop and efficiencies. 6. All orders shall be shrink wrapped and palletized. HVAC - HEPA FILTERS Ordering Information The design and construction of Purolator Filtration Systems modules are coded with an assembly part number, divided into sections consisting of the following information: U V E X T X B U F S U Type 2 Frame Material 3 Efficiency 4 Filter Size 5 Sealant 6 Seal 7 Faceguard 8 U.L. Section 1: Type of Product UV = ULTRA-Cell V-Pleat Section 2: Frame Material EXT = Anodized, extruded aluminum Section 3: Efficiency 97 = 99.97% on.3 micron 99 = 99.99% on.3 micron Section 4: Filter Size = 24" x 24" x 11-1/2" = 24" x 12" x 11-1/2" Section 6: Fluid Seal FSU = Fluid seal upstream FSD = Fluid seal downstream FCU = Fluid seal upstream w/clips for fluid seal housing FCD = Fluid seal downstream w/clips for fluid seal housing Section 7: Faceguard Location 00 = No faceguard Section 8: U.L. Classification 09 = UL 900 Class 2 00 = None Section 5: Frame Style Sealant XBU = X-Body/urethane sealant Note: For Part Number Information and Pricing, Please Contact Customer Service. P-ULTRACELL-V

79 Introduction ASHRAE holding frame is a 3", 16-guage galvanized steel ASHRAE holding frame that can be used to hold filters individually, or be used in mutiple banks. All filters are held in place with individual clips to accommodate a wide variety of filters measuring 1" 12". Each Frame is manufactured with several features of construction which support use in a variety of HVAC applications and ensure it will outperform the competition. Construction Features Available in 16-gauge galvanized steel or type 304 stainless steel. Mechanicaly controlled production gurantees Sheared deburred performed edges, Mounting alignment dimples, and flush Mitered/welded corners. Suggested Specifications 1.) Holding frames shall be the ASHRAE holding frame type. 2.) These shall be constructed of 16-guage galvanized Type 304 stainless steel. 3.) All corners shall be mitered, continuously welded and ground to form a smooth surface between the frame sealing surface and gasket at the corner points of the sealing flange. 4.) All sheared edges of the frame shall be deburred prior to final assembly. 5.) The holding frames shall have pre-punched mounting holds to assure proper alignment and assembly Size Availability (H" X W") 24"x 24" 20"x 20" 24"x 12" NOTE: Clips information is on the reverse HVAC - HOLDING FRAMES, CLIPS, HOUSINGS 79

80 HVAC - HOLDING FRAMES, CLIPS, HOUSINGS 12" PCA-Spring 6" PCA-Spring 2" Pre-Filter Clip 4" Pre-Filter Clip 12" Spring 6" Spring 2" Corner Clip 1/2" - 12" Clip WF611 Clip GC611 Clip For Part Number Information and Pricing, Please Contact Customer Service. 80

81 HVAC - ULTRAVIOLET EQUIPMENT AND PARTS V-MOD - Built-Up or Side Access Modular Ultraviolet Lamp System VALUABLE BENEFITS FROM THE LEADER IN THE APPLICATION OF UV Doubles as a side access fixturing system in addition to its traditional built-up bank arrangement all in one unit Maintains AHU capacity to optimal operating condition with near original equipment capacities Lowers energy costs for most systems Reduces costly maintenance and cleaning programs With short payback periods, the V-Mod has one of the lowest ownership costs in the industry Improves indoor air quality by destroying surface microbes that grow on coils and in drain pans, including mold and bacteria Reduces infectious disease microbes including colds, flu, and other viruses UV has proven effective on Mycobacterium tuberculosis (TB), Legionella pneumophila (Legionnaire s disease), and other infectious bacteria Produces no ozone, gases, or other noxious fumes will not harm building occupants, equipment or furnishings ALTRU-V Lamps have the lowest output loss in the industry (over their operating life) Fixtures have their own safety switches that disable operation when not properly installed Fixtures are UL/C-UL Listed under Category Code ABQK (Accessories, Air Duct Mounted), UL Standards: 153, 1598 & 1995, respectively Installs easily and safely into systems of virtually any size, large or small One-year warranty on both the fixture and the lamp Part Number Description Model No. Nom. Dim. Electrical Weight V-Mod 18, 120 V-S/S Modular Coil Irradiator VM * 18" 120Vac, Hz,.5A 3 Lbs V-Mod 24, 120 V-S/S Modular Coil Irradiator VM * 24" 120Vac, Hz,.5A 5 Lbs V-Mod 36, 120 V-S/S Modular Coil Irradiator VM * 36" 120Vac, Hz,.8A 6 Lbs V-Mod 18, 240 V-S/S Modular Coil Irradiator VM ** 18" 240Vac, Hz,.25A 3 Lbs V-Mod 24, 240 V-S/S Modular Coil Irradiator VM ** 24" 240Vac, Hz,.25A 5 Lbs V-Mod 36, 240 V-S/S Modular Coil Irradiator VM ** 36" 240Vac, Hz,.4A 6 Lbs V-Mod 18 Replacement Lamp VM-18-T8 16" - 2 Lbs V-Mod 24 Replacement Lamp VM-24-T10 22" - 2 Lbs. D V-Mod 36 Replacement Lamp VM-36-T8 34" - 2 Lbs S/S Mounting Rails (8' lengths - 2 per box) MR Lbs S/S Hard Wire Module (one for each fixture row) HWR-120V* - 1 Lbs S/S Hard Wire Module (one for each fixture row) HWR-240V** - 1 Lbs Glass View Port Assembly GVP - 3 Lbs V-Mod Access Door (8" x 8") VM-AD - 4 Lbs V-Mod Access / View Port Door (8" x 8") VM AVD - 4 Lbs. Part Number Dim. A Dim. B * UL/CUL LISTED **CE REGISTERED 81

82 HVAC - ULTRAVIOLET EQUIPMENT AND PARTS V-FLEX - High-Intensity UV Air Stream and Surface Disinfection System VALUABLE BENEFITS FROM THE LEADER IN THE APPLICATION OF UV Provides unmatched installation flexibility and kill rates in HVAC systems of virtually any size, large or small Patent-pending design with multiple lamp capability per Extrusion. Lamps can be mounted to any of the four support faces. Extrusion can be cut to accommodate any height system Multiple high-power, single-ended biaxial lamps mounted to a single extrusion as close as 10 inch centers on each face Extrusions are typically installed 32" apart to cover any width system Allows for nesting and overlapping to accommodate any width or provide unprecedented UV intensity The only commercial, industrial or institutional UV device to offer 360 UV irradiance Installs easily and requires only one electrical service hook-up per Extrusion ALTRU-V Lamps have the lowest output loss in the industry (over their operating life) Fixtures are UL/C-UL Listed under Category Code ABQK (Accessories, Air Duct Mounted), UL Standards: 153, 1598 & 1995 respectively Optimize any application through our V-Smart proprietary application software Part Number Description Model No. Nom. Dim. Electrical Weight V-Flex UV Module VF Vac/240Vac, 50-60Hz,.6A/.3A 2 Lbs V-Flex Power Junction Module VF-PJM - 1 Lbs V-Flex Main Extrusion Kit (Includes Wire Raceway covers) VF-ME 32.5" - 10 Lbs V-Flex Duct Mount Brackets (2) VF-DMB 28.5" - 1 Lbs V-Flex Replacement Lamp VM-60 15" - 1 Lbs Glass Viewport Assembly GVP - 3 Lbs Safety Switch for Accesses 120Vac SS - 1 Lbs. 82

83 HVAC - ULTRAVIOLET EQUIPMENT AND PARTS V-RAY Small Unit System - Ultraviolet Lamp System Fan / Coil VALUABLE BENEFITS FROM THE LEADER IN THE APPLICATION OF UV 4-lamp sizes (12", 21", 33" and 61") Lowest mercury content available UV output regulated to keep levels within ACGIH and NIOSH exposure guidelines (patent pending) thus Extending lamp life and Ensuring safe exposure limits for room occupants or materials UL recognized components, ETL Listed Ideal for any vertical or horizontal system Ease of installation Simple Lamp Clasps (magnetic Lamp Clasp optional) Single point electrical connection UVC resistant materials Screw terminals for easy field wiring Remotely located power source offering ease of installation and mounting options Restores air handling unit to near optimal operating capacities Can lower energy costs for restored systems Reduces costly maintenance and cleaning programs Eliminates foul system odors (dirty sock syndrome) Has one of the lowest ownership costs in the industry Improves indoor air quality by destroying system microbes Will not harm building occupants, equipment or furnishings One-year warranty on both the fixture and the lamp Part Number Description Model No. Lamp Dim. Electrical Weight V-Ray UVC Fixture VRSUS * Vac, Hz, 11 Watts 3 lbs V-Ray UVC Fixture VRSUS Vac, Hz, 15 Watts 3 lbs V-Ray UVC Fixture VRSUS Vac, Hz, 21 Watts 3 lbs V-Ray UVC Fixture VRSUS * Vac, Hz, 31 Watts 5 lbs V-Ray UVMagClasp (Pair) VR MC 0.5 lbs. * The V-Ray 12 and 64 units are non-inventory items subject to varying lead times. Part NO: DIM L

84 HVAC - ULTRAVIOLET EQUIPMENT AND PARTS V-STRIKE - External System Mount Ultraviolet Fixture VALUABLE BENEFITS FROM THE LEADER IN THE APPLICATION OF UV Waterproof NEMA 3 design for outdoor locations Heavy gauge steel, tamper-resistant enclosure Installs easily and safely into through the wall and rooftop units up to 10 tons Maintains AHU capacity to optimal operating condition with near original equipment capacities Lowers energy costs for most systems Reduces costly maintenance and cleaning programs With short paybacks, the V-Strike has one of the lowest ownership costs in the industry Improves indoor air quality by destroying surface microbes that grow in and on coils and drain pans, including mold and bacteria Helps to reduce infectious disease microbes including colds, flu, and other viruses UV has proven effectiveness on Mycobacterium tuberculosis (TB), Legionella pneumophila (Legionnaire s disease), and other infectious bacteria Produces no ozone, gases, or other noxious fumes will not harm building occupants, equipment or furnishings ALTRU-V Lamps have the lowest output loss in the industry (over their operating life) Fixtures are UL/C-UL Listed under Category Code ABQK (Accessories, Air Duct Mounted), UL Standards: 153, 1598 & 1995 respectively One-year warranty on both the fixture and the lamp Replace lamps just once a year. Lamp change-out can take less than 5 minutes Part Number Description Model No. Nom. Dim. Electrical Weight V-Strike XS, 120/240V-Single Ended Fixture (Side Mount) VS-XS 120Vac/240Vac, 60 Hz,.7A/.4A 7 Lbs V-Strike XT, 120/240V-Single Ended Fixture (Top Mount) VS-XT 120Vac/240Vac, 60 Hz,.7A/.4A 6 Lbs V-Strike XS/XT, 32" New/Replacement Lamp VS-32-T5 32.5" - 5 Lbs V-Strike XS/XT, 28" New/Replacement Lamp VS-28-T5 28.5" - 4 Lbs V-Strike XS/XT, 15" New/Replacement Lamp VS-15-PLL 15" - 2 Lbs. 84

85 HVAC - ULTRAVIOLET EQUIPMENT AND PARTS V-RES - Residential Air Treatment System You can do something about it the ground-breaking V-RES Air Treatment Device uses well proven UV-C germicidal technology. This is the same proven technology used for decades in hospitals, food processing and water treatment facilities. Properly applied, UV germicidal irradiation technology can provide Between 8% to 14% improvement in air flow through your air conditioning coil, resulting in lower energy consumption Reduced risk of contaminants that cause infections and epidemics Fewer sick days, less complaints and higher productivity due to a significant reduction in colds and allergies Marked improvements for asthma sufferers which can lead to less medication and a higher quality of life Continues cleaning while in operation A healthier and safer indoor environment Performance Operates at a standard 110 volts Designed for installation in residential ducts Overall dimension: 3.5 (H) X 4.5 (W) X 6.0 (L) 2 year bulb life Available in 36 or 60 watt formats Reasons why the new V-RES Air Treatment Device represents the best available technology Product designed for ease of installation and maximum safety mounts directly above cooling coil in a standard furnace system Mathematically modeled application software validates the system to provide 99.99% kill of Influenza A virus within one hour with standard home air re-circulation systems Clinically proven to kill bacteria, molds, viruses and other pathogens on surfaces and in air streams Multiple safety interlock functions provide 100% protection against exposure to UV-C light Mounting base includes safety switch which is activated only when the unit is safely mounted on the outside of the duct Ease of removal and replacement of standard replacement lamps Complies to UL standard codes Systems are the easiest to install and fit in almost all existing home HVAC systems Backed up by the largest provider of UV air treatment products in the marketplace 85

86 HVAC - ULTRAVIOLET EQUIPMENT AND PARTS ECO-PURE - Mobile Room Sanitizer Surface sanitation up to 100% for bacteria, viruses and mold Only design on the market certified to UL and CSA standards and FCC CFR47 Part 18 Sanitizers typical operating suits, patient rooms, class and hotel rooms within several minutes Only unit on the market with IR motion detection to protect personnel Robust and user-friendly design allows for ease of transpiration and use in a number of applications Uses & applications for vacant: Operating Suites Patient and Waiting Rooms Class and Gymnasium locker Rooms Hotel Rooms Detention Centers Homeless Shelters Food preparation and processing areas Veterinary Clinics and Kennels Mold Remediation Key Design Features: Four (4) high output extended length UVC Teflon coated lamps which deliver enough energy to deactivate molds in less than 3 hours Treatment time less than 5 minutes for bacteria and viruses Digital timer/counter to set actual sanitizing cycle time up to 99 hours Four (4) infrared motion sensors to automatically shut off device if someone enters the room during the sanitizing cycle Built in stainless steel reflectors to better distribute the light to all room surfaces being treated Three casters to make it easy to transport the unit from room to room. Casters can also be locked in place Tri-color LED indicates status of operation 86

HVAC - PANEL AIR FILTERS

HVAC - PANEL AIR FILTERS Fiberglass MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS The F312 disposable panel filters are designed to withstand the demands of tough industrial and commercial applications. Purolator assures

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence 3M Purification Inc. 3M Air Management s for Your Commercial HVAC Needs Create an Air of Confidence Pursuing Innovation 3M Company has long encouraged employees to pursue ideas and concepts that might,

More information

Tubing and Accessories

Tubing and Accessories Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3

More information

Air Filter Selection Guide

Air Filter Selection Guide Air Filter Selection Guide It s Not Just Air, It s the Source of Life. Disposable Filters Heavy Duty Box Frame Filter - MERV 4 Spun Glass (Model # 10255) or Synthetic (11255) Media Flanders HD Industrial

More information

Laminar Flow Cabinets

Laminar Flow Cabinets Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical

More information

PAAM COMMERCIAL PRIVATE LIMITED

PAAM COMMERCIAL PRIVATE LIMITED METAL PACKAGING We at Paam Group have been providing vast range of packaging products to our customers based on their preferences, needs and specifications. We provide all the materials required in metal

More information

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS

SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications

More information

How to Choose An Air Filter For Your Boat

How to Choose An Air Filter For Your Boat How to Choose An Air Filter For Your Boat That Will Reduce Diesel Fumes, Smoke and Odors L-2395 Rev. 1-07-06 Air Filtration Fundamentals Air filters are devices that capture dust and other contaminants

More information

Dust Filtration Catalogue

Dust Filtration Catalogue www.filterteknik.dk Dust Filtration Catalogue Pre filtration mats Glass fibre mats Pocket filters Panel filters Compact filters Cassette filters Dust filters Dust Filtration Catalogue In order to show

More information

LiftAlloy Chain Slings

LiftAlloy Chain Slings CHAIN SLING BASICS Slings Lift-All chain slings meet or exceed all OSHA, ASME B30.9 and NACM standards and regulations. chain slings, available in 80 for 7/32" and 7/8"- /4" and 00 for 9/32"-3/4", are

More information

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements

More information

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 Fire Barrier Moldable Putty+ Pads 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 e-mail: [email protected] Visit Our Web Site at www.fireretardantsinc.com Protecting

More information

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual Montecito Series Vinyl The offers the outstanding insulating properties, low maintenance, and contemporary aesthetic appeal only vinyl can provide. Available in White and Tan homogenous window frames,

More information

FIRE DAMPER APPLICATION GUIDE

FIRE DAMPER APPLICATION GUIDE FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire

More information

3M Dual Lock Reclosable Fastener

3M Dual Lock Reclosable Fastener 3 Dual Lock Reclosable Fasteners SJ3550CF (Type 250) SJ3551CF(Type 400) SJ3552CF(Type 170) Dual Lock Reclosable Fastener Black with a clear acrylic adhesive Product Information February, 2007 Product Description

More information

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice G U National Air Filtration Association Recommended Practice I D E L I N E Procurement Guideline TRAINING EDUCATION CERTIFICATION HVAC Air Filter Purchasing Specification Guideline 1.0 Purpose To provide

More information

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,

More information

plenum slot diffusers

plenum slot diffusers light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4

More information

Dot matrix Label ID Products. C Vinyl cloth labels. Dot Matrix. Features and benefits. Part numbering system

Dot matrix Label ID Products. C Vinyl cloth labels. Dot Matrix. Features and benefits. Part numbering system Dot Matrix C Vinyl cloth labels Tyco Electronics C is a dot matrix printable vinyl coated cloth material with a permanent acrylic adhesive that is designed for application to irregular surfaces where conformability

More information

Right Angle Grinder USA MADE FLAP DISCS

Right Angle Grinder USA MADE FLAP DISCS USA MADE FLAP DISC Right Angle Grinder CGW Offers the Most Extensive Line of Flap Discs in the Marketplace CGW flap discs blend and finish in one operation which replaces the traditional twostep grinding

More information

HIGH PERFORMANCE FILTERS AND ELEMENTS

HIGH PERFORMANCE FILTERS AND ELEMENTS HIGH PERFORMANCE FILTERS AND ELEMENTS FILTRATION Fil*tra*tion (fil-tra-shen) n. The act or process of filtering. What exactly is filtration and why is it an integral part of today s industries? Simply

More information

The corrugated box: A profile and introduction

The corrugated box: A profile and introduction The corrugated box: A profile and introduction 1 More than just a plain brown box Ninety to ninety-five percent of U.S. manufactured goods are shipped to consumers in corrugated containers. In fact, more

More information

Labels. Fuji Xerox Document Supplies Catalogue 2010. Contents. Colotech labels 3. Copier/laser and inkjet printer labels 4.

Labels. Fuji Xerox Document Supplies Catalogue 2010. Contents. Colotech labels 3. Copier/laser and inkjet printer labels 4. Fuji Xerox Document Supplies Catalogue 2010 Contents Colotech labels 3 Copier/laser and inkjet printer labels 4 Clear labels 4 High speed labels 5 Custom labels 5 Software Series labels 6 Laser business

More information

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to

More information

Double Coated Urethane Foam Tapes

Double Coated Urethane Foam Tapes 3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear

More information

3 Single-Coated Foam Tapes

3 Single-Coated Foam Tapes 3 Single-Coated Foam Tapes Technical Data May, 2008 Product Description 3M Single-Coated Foam Tapes will adhere to a variety of substrates, including latex-painted wood, lacquered wood, enameled steel,

More information

TTP THERMAL TRANSFER PRODUCTS

TTP THERMAL TRANSFER PRODUCTS TTP THERMAL TRANSFER PRODUCTS High Performance Labels IDENTCO International is a global supplier of high quality, pressure sensitive labels, graphic overlays, and die-cut products. For over twenty-five

More information

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010. SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall

More information

Solvent Cementing Instructions For Plastic Pipe & Fittings

Solvent Cementing Instructions For Plastic Pipe & Fittings Solvent Cementing Instructions For Plastic Pipe & Fittings Description Solvent cementing is the process of fusing plastic pipe and fittings by the use of an adhesive containing a suitable active solvent

More information

Technical Data Sheet February 2014

Technical Data Sheet February 2014 Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products

More information

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use

More information

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs. COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35

More information

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

GENERAL RUBBER LINING PRINCIPLES

GENERAL RUBBER LINING PRINCIPLES GENERAL RUBBER LINING PRINCIPLES I. METAL PREREQUISITES Metal to be lined should meet the requirements as stated in section 8 Metal Fabrication and section 12 Blasting and Cementing Procedures. The surface

More information

Introduction: Consumables - Part of the Identification System

Introduction: Consumables - Part of the Identification System Consumables - The Basics A presentation from: Introduction: Consumables - Part of the Identification System You have spent many hours researching, selecting, and getting approval for your new data collection

More information

SAMPLE TEST QUESTIONS MOTOR VEHICLE BODY REPAIRER- ITA WEBSITE

SAMPLE TEST QUESTIONS MOTOR VEHICLE BODY REPAIRER- ITA WEBSITE 1 How are spot welds located on the underside of an apron? A. Heat the undercoat with a torch. B. Visually inspects with a trouble light. C. Grind the surface with an angle grinder. D. Clean factory seams

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

Bafl-Sorb Sound Absorbing Ceiling Baffles

Bafl-Sorb Sound Absorbing Ceiling Baffles Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding

More information

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS800.09. Description. Key Features and Benefits. Typical Physical Properties

IS800 Series. Technical Data Sheet IS802, IS803, IS808, IS800.09. Description. Key Features and Benefits. Typical Physical Properties 1810.html Technical Data Sheet IS800 Series IS802, IS803, IS808, IS800.09 Description IS802, IS803, IS808 and IS800.09 one-component, ready-to-use silicone adhesive sealants have a paste-like consistency

More information

Series 18 Pass Thru Air Lock Cleanroom Entry System

Series 18 Pass Thru Air Lock Cleanroom Entry System OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: [email protected]

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE Contains penetrants, lubricants and greases All weather Water-resistant Penetrates like an oil, then cures to a thick, water-resistant grease Recommended

More information

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS Perry Fiberglass Products, Inc. FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS PERRY FIBERGLASS Perry Fiberglass Products, Inc. is a leading manufacturer of high

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11 CONTENT peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11 PEEL ADHESION Testing the peel adhesion on stainless steel 1. Definition Peel adhesion - The

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

Basics of HVAC Cleaning

Basics of HVAC Cleaning Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

TECHNICAL DATA RS-6100. European Clear EZ. 5751 N. Webster Street Dayton, OH 45414-0802 Phone 937-890-6547 Toll Free 800-257-6547 Fax 937-890-6320

TECHNICAL DATA RS-6100. European Clear EZ. 5751 N. Webster Street Dayton, OH 45414-0802 Phone 937-890-6547 Toll Free 800-257-6547 Fax 937-890-6320 RS-6100 TECHNICAL DATA European Clear EZ DESCRIPTION: RS-6100 European Clear EZ is formulated with premium European resins. It is ideal for excellent color matching on white, light colors and metallics

More information

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001 3 Scotch-Weld TM Technical Data July, 2001 Introduction 3M Scotch-Weld AF 6, AF 10, AF 13 are unsupported, thermosetting adhesives in film form developed for the structural bonding of metals. These products

More information

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1 1.5 x 1. Features: Will not rust. Corrosion resistant. Non-sparking. Fire retardant. Non-conductive. Maintenance free. Molded-in color. Light weight. Easy to install. Impact resistant. Quality appearance. Fabcograte

More information

MaxCell Technical Manual Design Parameters

MaxCell Technical Manual Design Parameters MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50

More information

Minor Cracks in Horizontal Surfaces

Minor Cracks in Horizontal Surfaces Cracks, chips and broken or flaking areas in concrete are not only unsightly, they can lead to further deterioration of the surface. The result is a costly replacement project as opposed to a simple repair.

More information

www.setfil.com COARSE DUST FINE DUST GAS ADSORPTION EPA HEPA ULPA Product Catalogue Filters for HVAC Systems and Cleanrooms

www.setfil.com COARSE DUST FINE DUST GAS ADSORPTION EPA HEPA ULPA Product Catalogue Filters for HVAC Systems and Cleanrooms www.setfil.com COARSE DUST FINE DUST GAS ADSORPTION EPA HEPA ULPA Product Catalogue Filters for HVAC Systems and Cleanrooms INDEX 2 About SetFil 3 Filtration Product Overview FILTER MATS DustMax Rolls

More information

Cable Tie Mounting Bases

Cable Tie Mounting Bases Temperature Rating: 0ºC to 66ºC (32ºF to 150ºF) *Synthetic Rubber Adhesive Choose from adhesive-backed, epoxy or screw mounting bases! Available in a variety of materials for both indoor and outdoor use

More information

PAINT BOOTH LIGHTING

PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting

More information

Camfil Farr Technical Services Bulletin

Camfil Farr Technical Services Bulletin Camfil Farr Technical Services Bulletin ASHRAE Testing for HVAC Air Filtration A Review of Standards 52.1-1992 & 52.2-1999 The American Society of Heating, Refrigeration, and Air Conditioning Engineers

More information

security products metric sizes Redefine your comfort zone. www.titus-hvac.com

security products metric sizes Redefine your comfort zone. www.titus-hvac.com metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table

More information

Sikaflex Sealant Installation. Sika Corporation

Sikaflex Sealant Installation. Sika Corporation Sikaflex Sealant Installation 1 Critical Success Factors Substrate preparation If done properly would probably eliminate 95% of all call backs Most common mode of sealant failure Must remove all weak material

More information

HOSE & CABLE PROTECTION

HOSE & CABLE PROTECTION HOSE & CALE PROTECTION Product Page AccessTrak, TrukTrak and TredTrak 2-5 FloorTrak 6 CableTrak Modular Carrier Track 7-9 Page 2 HOSE and CaLE PrOTECTION Features and enefits The AccessTrak ramping system

More information

Crystal Clear Sealant

Crystal Clear Sealant Crystal Clear Sealant Technical Data February, 2012 Product Description 3M Crystal Clear Sealant is a one component thermoplastic elastomer which forms permanent elastic bonds when used in surface sealing

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION

More information

3 Laser Toner Printable Polyester Label Material 7840TL

3 Laser Toner Printable Polyester Label Material 7840TL 3 Laser Toner Printable Polyester Label Material page 1 of 5 Technical Data February 15, 1999 Supersedes July 1, 1997 Construction (Calipers are nominal values.) Facestock Adhesive Liner 2.3 mil (58 micron)

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013 Scotch-Weld TM Product Data Sheet Acrylic Adhesives Date: Supersedes: August 2013 Product Description 3M TM Scotch-Weld Acrylic Adhesives are high performance, twopart acrylic adhesives that offer good

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

Technical Data Honeycomb Door Leaf 8-1-99

Technical Data Honeycomb Door Leaf 8-1-99 8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix

More information

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401 BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential

More information

FLEX-WRAP Foam Pipe Wrap

FLEX-WRAP Foam Pipe Wrap FLEX-WRAP Foam Pipe Wrap Flex-wrap Inexpensive Used to wrap all pipes in a concrete pour Satisfies UPC Code Sec.315.7 Provides true expansion space between pipe and a concrete pour Product # Dimesions

More information

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants RTV159 RTV157 and RTV159 High Strength Silicone Adhesive Sealants Product Description RTV157 and RTV159 are one-component, ready-to-use, high strength silicone rubber adhesive sealants. They cure to tough

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Pyroguard Wired Glass

Pyroguard Wired Glass Fire-rated Glass Pyroguard Wired Glass Where glass becomes architecture Section 15 03 Introduction Oldcastle Glass stocks nonwired Pyroguard laminated safety glass and polished wired glass for commercial,

More information

SC2000 CEMENT BONDING PROCEDURES

SC2000 CEMENT BONDING PROCEDURES Pg.1 SC2000 CEMENT BONDING PROCEDURES Widely recognized as the world s finest cold vulcanizing cement REMA SC2000 is the solution to your industrial bonding problems. By using REMA UTR20 hardener with

More information

3M Electrically Conductive Adhesive Transfer Tape 9703

3M Electrically Conductive Adhesive Transfer Tape 9703 Technical Data April 2011 M Electrically Conductive Adhesive Transfer Tape 970 Product Description M Electrically Conductive Adhesive Transfer Tape 970 is a pressure sensitive adhesive (PSA) transfer tape

More information

RECOATING AND RENEWING SPF ROOFING SYSTEMS

RECOATING AND RENEWING SPF ROOFING SYSTEMS RECOATING AND RENEWING SPF ROOFING SYSTEMS Procedures, Regional Differences and type of coating systems Bruce Schenke Premium Spray Products REASONS TO RECOAT/RENEW Add a new coating layer to renew the

More information

H ILLYARD. String Mop Selection Guide

H ILLYARD. String Mop Selection Guide H ILLYARD String Mop Selection Guide Wet Finish Dust Selecting the Right Wet Mop to Meet Your Needs Looped-end vs. Cut-end Productivity, Mop Size and Staff Larger Mop Size, Greater Coverage* Productivity

More information

Electrical Safety Products

Electrical Safety Products Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg

More information

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS

CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS The City of Beaufort is requesting sealed, competitive, proposals for interested Vendors to provide the City of Beaufort fifty-five

More information

STOCK BOXES SIZE STYLE BUNDLE BALE NOTES

STOCK BOXES SIZE STYLE BUNDLE BALE NOTES STOCK BOXES SIZE STYLE BUNDLE BALE NOTES 4 x 4 x 4 RSC - 32 ECT C FLUTE 25 2000 4 x 4 x 48 5PF - 32 ECT B FLUTE 10 500 5 x 5 x 5 RSC - 32 ECT C FLUTE 25 2000 6 x 4 x 4 RSC - 32 ECT C FLUTE 25 2000 6 x

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

SECTION 08560 SERIES 1500 VINYL PATIO DOORS

SECTION 08560 SERIES 1500 VINYL PATIO DOORS SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish

More information

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Solid shape molding is not desired in injection molding due to following reasons.

Solid shape molding is not desired in injection molding due to following reasons. PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which

More information

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction

More information

vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and

vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? We are confident that we carry a style and size to suit your application. You can be sure that your investment will add value to your home,

More information

1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE

1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE 1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic

More information

Screw Plug Immersion Heaters

Screw Plug Immersion Heaters Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters

More information

Media Storage and Transportation

Media Storage and Transportation Media Storage and Transportation Media Cases NER offers a variety of media cases for movement of media both within the tape library and to offsite locations. DCT Cases Durable blow-molded outer shell High-density,

More information