1 Technical Services MICURA Measuring Center
2
3 1. Machine components, installation site and installation conditions When selecting the installation site, please make sure that the following conditions either already exist or can be implemented there. 1.1 Machine components The system comprises the following components: Coordinate measuring machine Controller Control console Data station (peripherals) 1.2 Required room height This dimension equals the sum of the CMM s height and the minimum installation clearance below the ceiling. For the required minimum room height above the floor or foundation, see page Floor space required The dimensions of your CMM are specified on page 10. If you are creating a floor plan on a CAD system, you can obtain a DXF and/or a DWG file with the corresponding dimensions. Please notify your contact person at Carl Zeiss if you require any such files. Before creating a floor plan, make sure that your coordinate measuring machine is accessible from all sides. Installation near transport routes should be avoided at all costs. Select the location so that the distance between the machine and the wall or other machines is at least 800 mm. 1.4 Transport routes Check the floor and ceiling loading capacity of the transport routes leading to the installation site. The doorways and transport routes must be at least 10 cm wider and higher than the packed CMM assemblies. The dimensions and weights of the CMM assemblies are specified in this document. 1.5 Ambient conditions Bridge-type CMMs are technically sophisticated products. The specified quality can be attained only if you observe the following conditions. Permissible storage temperature range 5 C to 40 C Pay special attention to the storage temperature in the winter. Storage at temperatures below 5 C must be avoided. Ambient conditions for operational readiness Permissible ambient temperature: +17 C to +35 C Permissible air humidity: 30% - 60% non-condensing Noise level at installation site: <90 db Height above sea level: at V: 3000 m at V: 2000 m Temperature conditions for operation of the CMM: The measuring uncertainty specified for your CMM is guaranteed under the following conditions: 1. Use of the measured value correction program with input of the workpiece and CMM temperatures and the thermal expansion coefficient of the workpiece material. 2. Observance of the following temperature conditions: 3
4 Temp. range Temperature gradient CMM type (ºC) per hour (K/h) per day (K/d) per m (K/m) MICURA Please see to it that sufficient lighting is available. The use of sources of heat near the coordinate measuring machine must be avoided at all costs. 1.6 General Protective Measures The CMM must be protected against dirt and foreign particles (e.g. casting sand, metal filings and bore chips, oil, coolants, lubricants and soot). Deposits of materials such as casting sand and swarf may lead to increased expenses for cleaning and maintenance. 1.7 Floor Load When calculating or planning any floor reinforcement (foundation etc.) which may be required, it is advisable to consult a statics engineer who is familiar with your local floor conditions. To determine the floor load exerted by the CMM, see the pertaining information in this brochure. 4
5 1.8 Vibrations at the Installation Site The following diagram(s) show(s) the permissible floor vibrations. Vibrations are often caused by heavy processing machinery, transport vehicles (cranes or stackers) and stamping or forging machines located in adjacent rooms. A measurement is required to determine the actual magnitude of local floor vibrations. You can order such a vibration analysis from Carl Zeiss Oberkochen. Please call or your contact person for more details. In any case, the results must be made available to CZO for evaluation. Acceleration [mm/ss] Permissible foundation accelerations for MICURA when measuring with standard damping Acceleration values above the curve require an additional foundation X axis, horizontal Y axis, horizontal Z axis, vertical 0, Frequency [Hz] 5
6 2. Preparation for installation/required connections/transport/storage The following preparations must be made prior to the installation date: 2.1 Preparing the Floor Surface The floor surface must be clean and the unevenness of the bearing surfaces must not exceed max. 25 mm. 2.2 Electric Power Supply We recommend connecting the system to a power source which does not supply electricity to peak-load or high-consumption equipment (elevators, air conditioning systems). Due to the possibility of negative influences, avoid installing the CMM near High-consumption equipment (e.g. welding machines) High-interference (EMI) equipment (e.g. electron discharge machines). The use of mobile telephones or walkie talkies within a radius of 3m surrounding the CMM is also prohibited. This precaution is necessary to prevent malfunctions, especially in connection with data processing systems. A permanent connection (max. 16A) must be provided for the system. Alternatively, a 3-wire CEE-form plug connection is also acceptable. A 5-plug multiplex outlet must be provided by you (the customer) for the data station. We recommend the on-site installation of a surge arrester, e.g. Phoenix Flashtrab FLT , as basic protection against surge voltage. We recommend making the connection as shown in the following drawing, taking into account that all pertaining national regulations also must be observed. Connection diagram Proposed permanent connection (customer installation (national voltage)) L N PE C16 A Fault current breaker (if required) Terminal box 3x 2.5 mm 2 cable included in scope of supply CMM Multiplex 3-wire outlet Multiplex outlet with 5x 3-wire sockets Connecting cable, min. 5 m Peripherals: max VA 2.3 Electric Power Supply Parameters To ensure trouble-free data transmission between the CMM and the data station, the line power supply must comply with the following specifications. Line power supply: Line voltage: 1/N/PE 100/110/115/120/125/230/240 VAC Max. voltage fluctuations: ±10 % Frequency: 50 or 60 Hz Max. frequency fluctuations: ±3.5% Max. power sag: 10 ms (Max. one half-wave may be missing at 50 Hz) Interference peaks Max. rise time at 5 ns: ± 500 V Max. rise time at 50 µs: ± 1000 V 6
7 Max. amount of heat generated: 3600 kj/h Max. total power requirement: CMM: max VA Peripheral workstation: max VA 2.4 EMC EN Appendix A, Class A Warning! This is a class A device, and may therefore cause radio interference in the surrounding area. In such cases, the operator may be required to take appropriate action and bear any costs thus incurred. 2.5 Stabilizing the line voltage If out-of-tolerance r.m.s. fluctuations of the nominal voltage briefly occur, a line analysis must be performed. Please contact us if you have such a requirement. We will be glad to advise you and suggest suitable measures. In most cases, it is sufficient to install a separate stub cable from the main distributor to the CMM. 2.6 Machine parameters Overvoltage category: III Pollution degree: 2 Protection class: Internet connection for teleservice You will require an Internet connection for Teleservice. For more details, please refer to the "Teleservice" brochure. 2.8 Compressed Air Supply Please make sure that the air pressure required to operate your CMM is available as described below: Minimum pressure 6 bar, max. pressure 10 bar. Prefiltered air; completely free of contaminating particles, oil vapors and water residues. Air quality in compliance with ISO 8573 Part 1 Classification 4, which includes: Par. 6.1: Max. particle size 15 µm, max. dirt particle concentration 8 mg/m 3 Par. 6.2: Max. compressed air dew point +3 C Par. 6.3: Max. oil concentration of 5 mg/m 3 If the air supply does not comply with the requirements stated above, an additional air filtration unit and, if necessary, a membrane dryer, must be connected upstream to the compressed air line. If the required air quality is not attained despite this measure, Carl Zeiss recommends contacting a pneumatics expert to solve the problem. Failure to comply with the above air quality specifications could result in damage not covered by your warranty. Air consumption of CMM: Max. 30 l/min at 5 bar (150 normal liters/min at 1 bar) 7
8 Connecting point for compressed air The customer must provide a suitable lockable isolator with an integrated pressure relief device for the pneumatic connection. A connection with a compressed air coupling for a ¼ NPT plug-in fitting is required to connect the machine to the compressed air supply. This connection must be provided by you as illustrated in the section entitled "CMM installation dimensions and arrangement of the steel plates". A compressed air hose with a ¼ NPT plug-in fitting (included in the scope of supply) must be laid and connected during installation. When laying the connection up to the CMM, make sure that the connecting parts are readily accessible and are not obstructed by the base of the CMM. 2.9 Transport Vehicles Remember that this CMM is a high-end, precision instrument. Always make sure that all CMMs and machine parts to be transported are securely fastened. They must not slip or slide, be jolted or fall off of the transport vehicle. Their center of mass also must be considered. These actions are necessary to prevent personal hazards and damage to the machines. Please provide a forklift with sufficient carrying capacity and fork length to unload the packaged units and transport them to the storage or installation site. The loading capacities required of these vehicles are specified on the following pages. All transport lanes and approaches should be kept open during the entire installation and startup period to help ensure trouble-free installation. The transport locks and braces on the CMM, pallet (shipping crate) and lashing straps must be returned to CZ. Packing materials such as e.g. foils or styrofoam chips ("popcorn") are recycled by Carl Zeiss and should be returned to CZ along with the transport stops and braces if they are clean and no dirt has been mixed in with them Unloading/Storing/Unpacking With outdoor temperatures below 0 C, CMM assemblies are not enclosed in a protective PVC bag, but sealed air-tight along with a drying agent in an aluminum-coated foil (insulated packaging). Unloading and transport must be performed only with transport lugs or pallets. Be careful not to damage the insulated packaging! Please remember that your CMM is a valuable, high-precision instrument. For this reason, you should avoid jolting or knocking the crate at all times. Please leave the crates packed and store them in a sheltered location as close as possible to the installation site. Adaptation to room temperature: Store the crates in a room with a minimum ambient temperature of 15 C at least 2 days before our system specialist arrives. The crates may be unpacked and the insulated packaging may be removed only by our system specialist! Please also make sure that a place suitable for depositing the empty containers is provided Moving the CMM to another location A system specialist should always be present when moving the CMM to another location as a precaution to ensure that it is not damaged. 8
9 3. Shipping Crates and Pallets 3.1 Dimensions and Weights The machine components are delivered on transport pallets with insulated packaging. They are delivered in a shipping crate only for air cargo and overseas shipments. H L W. Transport containers for Dimensions of containers in mm (max.) L W H Max. tare wt. (kg) Max. gross wt. (kg) m 3 Container Pallet w. container w. pallet sea/air truck sea/air truck MICURA X=500, Y=500, Z= Palbox with accessories Control Note: All specifications are maximum values. Values not entered were not available at the time of printing. For production reasons the dimensions specified for transport containers (L, W and H) may vary from the actual values by as much as +50 mm. 9
10 4. CMM installation dimensions, arrangement of steel plates, barrier 4.1 Installation dimensions (all dimensions in mm, scale 1:30) 715 MICURA min T-T X/Y/Z meas. range min /500/500 Control Length: ca. 756 Width: ca. 575 Height: ca. 700 Net weight of CMM Max. permissible workpiece wt. ca. 985 kg 280 kg T-T = Height between table and bottom of probe VASTXT probe 616 = Air supply connecting point, prefiltered compressed air 6-10 bar, to be installed by the customer. = Power = Telephone connection (ISDN/DSL) = Compressed air connection to CMM = CMM control connecting cable, approx mm = Height of secured CMM assembly incl. pallet = Height of secured CMM assembly without pallet and Z min. 800 supply (two outlets with max. 16 A), to be installed by the customer. tower = Transport height without pallet, base and Z tower 10
11 4.2 Arrangement of the steel plates The relative unevenness of the supporting surfaces must not exceed 25 mm (1 ). Deviation tolerance for center-to-center distances of plates (A) ±10 mm (all dimensions in mm) MICURA X=500, Y= Support (A): Cast metal plate, dia. 150mm (included in scope of supply) Supporting point: (tilt protection only) Floor load at the supports (A) MICURA X=500, Y= N/cm 2 11
12 4.3 Installation of Floor Stripe or Chain The dangers posed by the CMM are impossible - or at least difficult - for untrained personnel to recognize. For this reason, a restricted-access zone must be set up around the machine to prevent damage or injury caused by untrained personnel. The entrance to this area should be be clearly marked by a warning sign reading: "Admittance only for authorized personnel" and may be entered only by persons who have received proper training (operators). min. 200 min. 200 min. 800 ➂ ➀ min. 800 min. 800 min. 700 ➁ min. 100 min. 100 ➀ Floor marking or chain (black-and-yellow) ➁ Table or computer, monitor (optional). ➂ Control A minimum distance of 200 mm should be maintained between the back door of the control cabinet and the wall. Furthermore, air exchange with the environment must not be obstructed. The control cabinet must be located so that the rear side of the control always faces away from the CMM. 12
13 5. Dimensions of granite table and fastening holes 5.1 Measuring table for measuring range of X=500, Y= ,4 ➀ M12 (9) 500 ➁ ➂ 3 544, , ,8 89 Y X ➀ =Bridge column bearing surface ➁ =X-Y measuring range ➂ =Bridge drive bearing surface ➃ =Grid positions in X ➄ =Grid positions in Y 13
14 Carl Zeiss Oberkochen Printed in Germany SES-TD / 05.12
Lava. Precision Solutions. Site Planning and Installation Guide
Lava Precision Solutions Site Planning and Installation Guide TABLE OF CONTENTS Table of Contents Introduction...........................................................................................
Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales
Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP
Pre-installation Manual CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP Pre-installation Manual CONCEPT Processor 305 DW / 405 DW / 505 DW / 505 DW XP T11336 Edition AA, April 2013 This book has
Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
BB800 Off-Grid Solar System
BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
Uninterruptible Power Supply. 500 kva - 750 kva
9 315 Uninterruptible Power Supply 500 kva - 750 kva T1 and T3 Installation Addendum 164201244-001 Rev. A ------------------------------------------------------------------------ ------------------------------------------------------------------------
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October
Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ 100-200
Translation of the original manual Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ 100-200 Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 [email protected]
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining
[ E[M]CONOMY] means: Save time, money and space! MAXXMILL 500 Vertical milling center for 5-side machining MAXXMILL 500 MAXXMILL 500 is the ideal vertical milling center for the for the 5-axis operation
DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium
DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT User Manual SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium +32 (0)9/321.91.12 - Fax +32 (0)9/321.91.13 - e-mail: [email protected]
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Parallel Redundant Uninterruptible Power Supply
9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Power Management Module 2. Installation
Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
OPERATOR s MANUAL ROLL AND EXTENSION TABLES
OPERATOR s MANUAL ROLL AND EXTENSION TABLES 1 INDEX Page Manufacturer s Information 3 Warnings 4 Risks and Labelling 5 Safety Precautions 6 Warranty 7 Dimensions and Weight 8 Shipping Dimensions 8 Transport
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
HP Designjet L65500 printer series Site preparation checklist (second edition)
HP Designjet L65500 printer series Site preparation checklist (second edition) Legal notices 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125
Load Limiter ULS-60 ULS-80 ULS-100 ULS-125 Version 2.0 Last revision November 2012 Dear customer, Thank you for the confidence that you have placed in our company by purchasing an IPR load limiter. Every
Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C
Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
clean and quiet dental
clean and quiet dental clean air for your dental clinic JUN-AIR introduced the first compressor almost 50 years ago and started the development of the technology and design, which has made JUN-AIR compressors
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Walking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Membrane air dryers MS-LDM1, MS series
Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES
English AUTOMATION SYSTEMS FOR SLIDING GATES Operating and installation instructions SLIDE SERIES v.0 Rev /202 INDEX ) General Safety Regulations... pág. 0 2) Description... pág. 02 3) Technical Specifications...
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480
Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions
CNC Portal Milling Machine FZ 32. High Performance Milling Technology
CNC Portal Milling Machine FZ 32 High Performance Milling Technology FZ 32 HSC Portal Milling Machine with Overhead Gantry with upper moving portal high axial accelerations and perfect surface finishes
Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers
Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
ThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Bubble King. User Manual
Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
CELO5. User & Installation Manual. www.audac.eu
CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
Profile rail guides LLR
Profile rail guides LLR Content The SKF brand now stands for more than ever before, and means more to you as a valued customer. While SKF maintains its leadership as the hallmark of quality bearings throughout
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
Pos. Qty. Article Description Price / Drilling capacity in steel 60 Ø 25 mm Tapping capacity M 20 Milling capacity in steel 60 150 cm³/min.
Offer 1 1 Vertical CNC-machining centre model FZ 12 W Magnum Completely refurbished pre-owned machine Updated in 2015 Year of construction: depends, weight 4.000 kg Scope of delivery: Column moving machining
Climate chamber with illumination
KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural
Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415
Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Guidelines for Packing
ABB AG Calor Emag Medium Voltage Products Guidelines for Packing 19.04.2011 Guidelines for Packing 1 Gas-insulated switchgear type ZX Vacuum circuit-breaker Embedded Poles Vacuum interrupter Components
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion