REINFORCING STEEL NOTES: 1. REINFORCING SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS UNLESS SHOWN OTHERWISE.

Size: px
Start display at page:

Download "REINFORCING STEEL NOTES: 1. REINFORCING SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS UNLESS SHOWN OTHERWISE."

Transcription

1

2 BAR SIZE REINFORCEMENT EMBEDMENT AND SPLICE TABLES PSI BASIC TABLE MINIMUM EMBEDMENT LENGTH, INCHES MINIMUM LAP LENGTH INCHES FACE OF CONCRETE ALTERNATE TABLE MINIMUM EMBEDMENT LENGTH, INCHES MINIMUM LAP LENGTH INCHES TOP OTHER TOP OTHER TOP OTHER TOP OTHER CONCRETE SECTION EQUAL TO OR LESS THAN 12" THICKNESS CONCRETE SECTION GREATER THAN 12'' AND LESS THAN 24'' THICKNESS CONCRETE SECTION EQUAL TO OR GREATER THAN 24" THICKNESS REINFORCING STEEL NOTES: 1. REINFORCING SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS UNLESS SHOWN OTHERWISE. 2. REINFORCING BARS SHALL BE CONTINUOUS AT ALL CORNERS UNLESS OTHERWISE NOTED. 3. TACK WELDING REINFORCING BARS IS NOT PERMITTED. 4. ALL REINFORCING STEEL SHALL BE ASTM DESIGNATION A-615 (GRADE 60). 5. CONFORM WITH ACI 318 AND ACI STANDARD FOR "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT". 6. ALL STIRRUPS SHALL BE CLOSED. 7. REINFORCING DETAILS, ALL BENDS OF REINFORCEMENT AND ALL BAR SPACERS AND SUPPORTS SHALL BE IN ACCORDANCE WITH SP-66, AMERICAN CONCRETE INSTITUTE DETAILING MANUAL REINFORCING BAR DESIGNATION NUMBERS SHALL CONFORM TO THE NUMBERING SYSTEM OF THE CONCRETE REINFORCING STEEL INSTITUTE. 9. THE EMBEDMENT AND SPLICE TABLE SHALL BE USED IN DETERMINING LAP SPLICES AND EMBEDMENT LENGTHS WHERE LENGTHS ARE NOT OTHERWISE INDICATED. SPLICE LENGTHS SHALL BE BASED ON THE SMALLER BAR BEING LAPPED. THE CONTRACTOR WILL BE ALLOWED TO MAKE SPLICES IN ADDITION TO THOSE INDICATED IN THE DRAWINGS, WHERE ESSENTIAL TO CONSTRUCTIBILITY, SUBJECT TO APPROVAL THE CONTRACTING OFFICER. SPLICES OTHER THAN THOSE SHOWN ON THE DRAWINGS AND OTHER THAN ANY ADDITIONAL SPLICES REQUIRED THE CONTRACTING OFFICER, WILL BE AT THE CONTRACTOR'S EXPENSE. 10. ALL #11 BARS IN CONCRETE BEAMS SHALL BE EXTENDED INSTALLING MECHANICAL TENSION SPLICES THAT CONFORM TO ACI 318, AND DEVELOP AT LEASE 1.25 Fy OF THE BAR. 11. PROVIDE ALL BARS, CHAIRS, ACCESSORIES, ETC. AS REQUIRED TO MAINTAIN REINFORCING IN PROPER LOCATION AND ORIENTATION. 12. REINFORCEMENT, WHERE NECESSARY, TO AVOID OPENINGS, PIPES, EMBEDDED ITEMS AND OTHER OBSTRUCTIONS, SHALL BE BENT OR SHIFTED AS DIRECTED THE CONTRACTING OFFICER. CONCRETE NOTES: 1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH ( f'c ) OF 4000 PSI AT 28 DAYS. 2. CONSTRUCTION JOINTS SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS. WHERE NOT SHOWN, CONSTRUCTION JOINTS SHALL BE PLACED AT LOCATIONS LEAST LIKELY TO IMPAIR THE INTEGRITY OF THE CONCRETE STRUCTURE. THESE ADDITIONAL CONSTRUCTION JOINT LOCATIONS SHALL BE APPROVED THE CONTRACTING OFFICER. 3. ALL GROUT SHALL BE NON-METALLIC, NON-SHRINK GROUT EXCEPT AS NOTED OTHERWISE. 4. ALL EXTERIOR FORMED SURFACES SHALL BE CLASS "A" FINISH. TOP SLAB SURFACES SHALL RECEIVE A BROOM FINISH AFTER FLOATING IS FINISHED. 5. ALL METAL FABRICATIONS EMBEDDED IN CONCRETE OTHER THAN REINFORCING AND ANCHOR BOLTS SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATIONS IN ACCORDANCE WITH ASTM A PROVIDE SETTING TEMPLATES TO POSITION ANCHOR RODS AND BOLTS PRIOR TO PLACING CONCRETE. ACCURATELY POSITION RODS AND BOLTS TO ASSURE CORRECT VERTICAL AND HORIZONTAL LOCATIONS TO MATCH STEEL OR EQUIPMENT PATTERN. 7. GRADE BEAMS SHALL BE OF SIZE AND WITH REINFORCEMENT AS INDICATED ON PLANS. UNLESS EXISTING DETAILS DIFFER, PROVIDE 3/4" CHAMFER AT ALL EXPOSED EDGES AND EXTERIOR CORNERS. 8. PILES SHALL BE 24" X 24" PRESTRESSED PRECAST CONCRETE PILES AS SHOWN ON R-108. EMBEDMENT & SPLICE TABLE NOTES: 1. THE EMBEDMENT AND SPLICE TABLE SHOWN SHALL BE USED IN DETERMINING LAP SPLICES AND EMBEDMENT LENGTHS WHERE LENGTHS ARE NOT OTHERWISE INDICATED. SPLICE LENGTHS SHALL BE BASED ON THE LARGER BAR BEING LAPPED. THE CONTRACTOR WILL BE ALLOWED TO MAKE SPLICES IN ADDITION TO THOSE INDICATED IN THE DRAWINGS, WHERE ESSENTIAL TO CONSTRUCTIBILITY, SUBJECT TO APPROVAL THE ENGINEER. SPLICES OTHER THAN THOSE SHOWN ON THE DRAWINGS AND OTHER THAN ANY ADDITIONAL SPLICES REQUIRED THE PROJECT ENGINEER, WILL BE AT THE CONTRACTOR'S EXPENSE. 2. USE THE BASIC TABLE IF ALL THE FOLLOWING CONDITIONS ARE MET: REINFORCEMENT SPACING 1 1/2" (MIN) 3'' (MIN) 4" (MIN) A) CENTER-TO-CENTER BAR SPACING LATERALLY IS AT LEAST 3 BAR DIAMETERS. B) DISTANCE FROM THE CENTER OF A BAR TO THE NEAREST CONCRETE SURFACE MUST BE AT LEAST 2 BAR DIAMETERS. 3. THE ALTERNATE TABLE MAY BE USED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: A) CENTER-TO-CENTER BAR SPACING LATERALLY IS AT LEAST 5 BAR DIAMETERS. B) DISTANCE FROM THE CENTER OF A BAR TO THE NEAREST CONCRETE SURFACE MUST BE AT LEAST 2.5 BAR DIAMETERS. DRAWN : : REINFORCEMENT CLEARANCE DETAIL N.T.S. GENERAL CROSS-REFERENCING SYMBOLS A INDICATES SECTION OR DETAIL DESIGNATION; LETTER INDICATES SECTION NUMBER INDICATES DETAIL INDICATES SHEET SHOWN ON A DETAIL SYMBOL W/ VIEW SHOWN ON SAME DRAWING INDICATES SECTION OR DETAIL TAKEN FROM AND SHOWN ON THE SAME SHEET; LETTER INDICATES SECTION & NUMBER INDICATES DETAIL A X-XXX A C-XXX DETAIL SYMBOL W/ VIEW SHOWN ON ANOTHER DRAWING ALT W/ ALUM APPROX. AZ BITUM BFV B/L B.O. B.O.S. BOT B.S. C/E CJ CJP C/L CLR CMP CONC. CONT. CP CS DIA DWG EF EJ EL EW EXIST. FES F.F. F.F.E. FM GALV HDPE HT ABBREVIATIONS * UNLESS OTHERWISE NOTED ON EACH SHEET ALTERNATE WITH ALUMINUM APPROXIMATE AZIMUTH BITUMINOUS BUTTERFLY VALVE BASELINE BOTTOM OF BOTTOM OF SLAB BOTTOM BASE SLAB CONSTRUCTION EASEMENT CONSTRUCTION JOINT COMPLETE JOINT PENETRATION CENTER LINE / CONTROL LINE CLEAR CORRUGATED METAL PIPE CONCRETE CONTINUOUS CONTROL POINT CORRUGATED STEEL DIAMETER DRAWING EACH FACE EXPANSION JOINT ELEVATION EACH WAY EXISTING FLARED END SECTION FINISHED FLOOR FINISHED FLOOR ELEVATION FORCE MAIN GALVANIZED HIGH DENSITY POLYETHYLENE HEIGHT IFP LG MBW MAX MIN MIRR MISC MP NF No. OC OF PEMB PPC PRS P.S. - P/S RCP RCPA R.O.W. - R/W RS SF SPEC SST T&B T.O.S. T.O. - T/ T.O.W. TRS TYP U/G UNO W WM WSEL WT WWF INTERM FLOOD PROTECTION LONG METAL BUILDING MANUFACTURER MAXIMUM MINIMUM MIRRORED MISCELLANEOUS METAL PIPE NEAR FACE NUMBER ON CENTER OUTSIDE FACE PRE-ENGINEERED METAL BUILDING PRECAST, PRESTRESSED CONCRETE PERMANENT RETAINING STRUCTURE PROTECTED SIDE REINFORCED CONCRETE PIPE REINFORCED CONCRETE PIPE ARCH RIGHT-OF-WAY RETAINING STRUCTURE SILT FENCE SPECIFICATIONS STAINLESS STEEL TOP AND BOTTOM TOP OF SLAB TOP OF TOP OF WALL TEMPORARY RETAINING STRUCTURE TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE WIDTH WATER MAIN WATER SURFACE ELEVATION WEIGHT WELDED WIRE FABRIC GENERAL NOTES 1. ALL DIMENSIONS SHOWN REFER TO "FEET" UNLESS NOTED OTHERWISE. 4. IF CONCRETE COVER OR EDGE DISTANCE IS LESS THAN 1 BAR DIAMETER OF THE CENTER-TO-CENTER BAR SPACING LATERALLY IS LESS THAN 3 BAR DIAMETERS, SEE ACI 318 FOR APPROPRIATE GUIDANCE. 5. TOP BARS ARE HORIZONTAL BARS AND BARS INCLINED LESS THAN 45 DEGREES WITH RESPECT TO A HORIZONTAL PLANE WHICH ARE PLACED SUCH THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. 6. THE TABLES SHOWN ARE FOR NORMAL WEIGHT CONCRETE AND UNCOATED REINFORCING BARS. IF EPOXY-COATED BARS ARE USED, SEE ACI 318 LATEST EDITION FOR ADDITIONAL CONSIDERATIONS. 2. DRAWINGS ARE GENERALLY TO SCALE BUT SHOULD NOT BE SCALED. NTS IS SHOWN ONLY WHERE THE DRAWING IS OBVIOUSLY OUT OF SCALE. 3. DRAWING ARE PLOTTED FULL SIZE 22x34 AND HALF SIZE 11x CONTRACTOR SHALL CLEAN AND REMOVE ALL TRASH WITHIN PROJECT LIMITS OF CONSTRUCTION PRIOR TO END OF CONTRACT. 5. CONTRACTOR SHALL KEEP ALL PARISH, STATE AND FEDERAL HIGHWAYS CLEAN DURING CONSTRUCTION. GENERAL NOTES G-102

3 EAST BAYOU ROAD ROW EAST BAYOU ROAD STEEL NEEDLES AND GIRDERS WILL BE REMOVED OTHERS PRIOR TO CONSTRUCTION (NOT PART OF THIS CONTRACT) ISSUE FOR BIDDING REVISION 1. CONTRACTOR SHALL COORDINATE WITH AND OBTAIN PRIOR APPROVAL FROM SLFPA-WEST AND CPRA PROJECT REPRESENTATIVES BOAT LAUNCH OPERATIONS FOR FERRYING WORK FORCE, MATERIALS AND EQUIPMENT TO PLATFORM. 2. THE CONTRACTOR IS ADVISED THAT SLFPA-WEST ROUTINELY TEST PUMPS, WHICH CREATES CURRENT. THE CONTRACTOR SHALL NOT MOVE FLOATING PLANT DURING PUMP OPERATION AND SHALL SECURE FLOATING PLANT. STEEL NEEDLES AND GIRDERS TO REMAIN (DO NOT DISTURB) FLOATING PLANT SHALL BE NO MORE THAN 50' FROM DOCK, UNLESS APPROVED THE COAST GUARD NOTES: NO. 50'-0" MAX. CE DOCK FA ACE WORK SP LIMIT OF EXISTING LEVEE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF THE EXISTING LEVEE. CONTRACTOR SHALL REPAIR ANY LEVEE DAMAGE AT THEIR EXPENSE : ROAD ROW ALL EAST T-W EXISTING SECTOR GATE DISCHA RG CHANNE E L 3 ACCESS ROAD (SE IN PUM P STATIO E SHEET C-0 N PACKAG 21 E) 4 GENERAL SITE LAYOUT 4+00 X Y OU ROAD SEE C-1 FOR DET 31 AIL 1+00 EAST BAY 0+00 ROAD ROW ACCESS ROAD (SE IN PUMPST E SHEET ATION PAC C-0 KAGE) 21 SEE NOTE FUEL LIN CONDUITE ATTACHED STATIO SUPPORTS TO PUMP STATIO PROVID SEE DWN WORK PACKAG ED IN PUMN G MP-13 E. P 6 THIS PAC KAGE. FUEL YAR IN PUM D (SEE SHEET PSTATI ON PAC C-021 KAGE) TOE +3' LEVEE INTAKE LEVEE +4' +14' CROWN LEVEE +4' LEVEE INTAKE EXISTING PUMP STATION INTAKE SEE NOTE 1 INTAKE INTAKE INTAKE LEV CHANN EE TOE +3' EL BAN K +2' INTAKE CH ANNEL ROAD ROW X Y X Y EXISTING FUEL LINE. CONTRACTOR SHALL USE EXTREME CAUTION WHILE WORKING NEAR LINE. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO THE LINE DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY SPILLS RESULTING FROM DAMAGE DRAWN : LAT: LONG: Near Maps: July 9, 2015 G-103

4 FUEL DOCK STATION (EQUIPMENT NOT SHOWN, UNDAMAGED) 34'-0"(±) 36'-0"(±) NEEDLES REMOVED ( OTHERS) NEEDLES (TO REMAIN) 12'-0" 9'-0" 99'-0" 9'-0" 99'-0" 9'-0" 12'-0" 1 S S-102 SEE ENLARGED DEMOLITION PLAN FOR LIMITS OF MAJOR DAMAGE SEE ENLARGED REPAIR PLAN FOR LIMITS OF MAJOR REPAIR 2'-6" 3 22'-0" = 60'-0" 2'-6" 71'-0" DRAWN : : 3'-0" 27 9'-0" = 243'-0" 3'-0" 249'-0" STORAGE PLATFORM - PLAN SCALE: 1" = 10' NOTES: 1. ALL MEASUREMENTS SHALL BE FIELD-VERIFIED PRIOR TO CONSTRUCTION LEGEND: LIMITS OF DAMAGED CONCRETE LIMITS OF CONCRETE REMOVAL OVERALL STORAGE PLATFORM PLAN S-100

5 NO DAMAGE TO BEAM OR PILE 8'-6" 5'-6" GIRDER DAMAGE 1'-0" 2'-0" 30'-0" 5'-0" 3'-0" CRACKED PILE EXIST. 24" PPC PILE IN ITS POST-COLLISION POSITION APPROX. NOT SURVEYED (TYP. 3 LOCATIONS) EXIST. 24" PRE STRESSED CONCRETE PILES IN ORIGINAL POSITION 7'-6" GIRDER DAMAGE 6'-0" GIRDER DAMAGE 9'-0" MARINE FENDER REMOVED BARGE IMPACT 1'-6" 6'-6" GIRDER DAMAGE NO DAMAGE TO BEAM OR PILE EXISTING CONCRETE TO BE REMOVED DRAWN : : 1" SAW CUT SLAB AND CONCRETE GIRDER. MAINTAIN SUFFICIENT REBAR EXTENSION TO LAP #6 SLAB REINFORCEMENT 3'-0" 36"x30" CONC. BEAM REMOVE DAMAGED PILES 11 THRU AT AT THE MUD MUD LINE LINE DEMOLITION PLAN SCALE: 6" = 1'-0" 1 S-100 NOTES: 1. ALL MEASUREMENTS SHALL BE FIELD-VERIFIED PRIOR TO CONSTRUCTION. 2. SEE S-103 AND S-104 FOR PHOTOS OF DAMAGE AREA. LEGEND: LIMITS OF DAMAGED CONCRETE LIMITS OF CONCRETE REMOVAL (LIMITS OF WORK) INDICATES APPROXIMATE LOCATION OF THE TOP OF DAMAGED PILE. ENLARGED DEMOLITION PLAN S-101

6 4'-0" 1'-0" 3'-0" 2'-0" 3'-6" 9'-0" 1'-0" 1'-0" 1'-0" CLEAR CLEAR CLEAR INSTALL NEW MARINE FENDER TO MATCH B EXISTING ON COLUMN 15 S-103 EXIST. 24" PRE STRESSED A S-103 CONCRETE PILES REMOVE DAMAGE PILES TO MUD LINE 37'-0" TRANSVERSE BEAM DRIVE 4 NEW 24" PPC PILES LENGTH=105' TIP EL ' 6'-6" 1'-0" CLEAR 2'-0" 6" 2'-6" C/L PILE ROW NO DAMAGE TO BEAM OR PILE 8'-6" 7'-6" NO DAMAGE TO BEAM OR PILE 2'-0" 3'-0" LONGITUDINAL BEAMS 1" SAW CUT SLAB AND CONCRETE GIRDER. MAINTAIN SUFFICIENT REBAR EXTENSION TO LAP #6 SLAB REINFORCEMENT. MECHANICAL COUPLERS SHALL BE USED FOR #11 BEAM REINF. EXIST. 36" x 30" CONC. BEAM TO REMAIN 5'-0" A S-104 DRAWN : : REPAIR PLAN SCALE: 6" = 1'-0" 1 S-100 NOTES: 1. ALL MEASUREMENTS SHALL BE FIELD-VERIFIED PRIOR TO CONSTRUCTION. 2. SAW CUT SLAB AND GIRDERS AND REMOVE DAMAGED CONCRETE TO LIMITS SHOWN. ROUGHEN ALL CONCRETE SURFACES ADJACENT TO THE NEW CONCRETE POUR. 3. RE-ESTABLISH #11 BEAM REINFORCEMENT WITH 125% CAPACITY MECHANICAL SPLICES. RE-ESTABLISH #6 SLAB REINFORCEMENT WITH ACI-REQUIRED LAP SPLICES. ALL REINFORCEMENT SHALL BE CLEANED BEFORE CONCRETE PLACEMENT. 4. NEW TRANSVERSE BEAM AND CONTINUATIONS OF EXISTING LONGITUDINAL BEAMS SHALL BE CAST MONOLITHIC. 5. REMOVE RIP RAP AT LOCATION OF NEW PILES PRIOR TO DRIVING PILES AND REPLACE RIP RAP AFTER NEW PILES ARE DRIVEN. 6. MARINE FENDER PILE 14 SHALL HAVE MOUNTING HOLES CAST INTO PILE AS SHOWED ON R-110. TRAPEZOIDAL FENDER, MOUNTING HARDWARE AND BUILD UP SPACERS BEAM ARE SHOWN ON R SEE SHEET R-108 FOR CONCRETE PILE DETAILS. LEGEND: NEW CONCRETE BEAMS LIMITS NEW CONCRETE SLAB NEW 24" PPC PILE LENGTH = 105.5' ENLARGED REPAIR PLAN S-102

7 1 1/2" CLR. SLAB REINF. ROUGHENED SURFACE #6 LAP PER ACI REQUIREMENTS TOP & BOT. 1% SLOPE 18" SLAB REINF. EA. FACE #4 STIRRUP 12" 18" EA. FACE 6" 4" CLR. TOP OF CONCRETE EL CLR. 4" NEW BEAM REINF. 8" 1'-10" NEW 24" SQUARE PRE-STRESSED CONCRETE PILE 1'-0" EMBED 4- #6 BARS TOP & BOT. 6" EXIST. STRUCTURE 4" CLR. SECTION SCALE: 1" = 1'-0" 8'-6" A S-102 3'-0" 1'-0" DRAWN : : ROUGHENED SURFACE 4" CLR. MECHANICAL SPLICE FOR #11 BARS BEAMS SLAB 18" SLAB REINF. EA. FACE 4" CLR. NEW BEAM REINF. 1% SLOPE 6" 4" CLR. 2" CLR. SLAB REINF. TOP OF CONC. EL " #6 LAP PER ACI REQUIREMENTS 2" CLR. EXIST. BEAM REINF. LEAVE 12" EXTENSION OF EXISTING #11 FOR MECHANICAL SPLICER ATTACHMENT 6" MAX. EXISTING STRUCTURE 6" BEAM REINF. #4 12" STIRRUPS 6" MAX. SECTION SCALE: 1" = 1'-0" 8'-6" B S #6 BARS TOP & BOT. 3'-0" NEW BEAM 1'-0" #4 STIRRUP 12" STD. 90 HOOK 1'-10" 24" SQUARE PRE-STRESSED CONCRETE PILE (BEYOND) REINFORCING SECTIONS SHEET 1 OF 2 S-103

8 1'-10" 8" 1 1/2" CLR. #6 LAP EXISTING SLAB 18" 6" 1'-0" 18" 1'-0" 6" 1'-0" 18" ROUGHEN EDGE 2'-0" 6" 3'-0" 4- #6 CONT. ACROSS NEW TRANSVERSE BEAM 18" 3" CLR. 18" NEW PILE BEYOND 4- #6 (2) OUTER BARS CONT. W / STD. 90 ENDS (2) INSIDE BARS STD. 90 PILE CONFLICTS 6'-0" 6" #4 STIRRUP 12" O.C. OMIT OVER PILES BEAM-TO-BEAM CONNECTIONS 4- #6 CONT. ACROSS NEW TRANSVERSE BEAM 18" 1'-0" 6" 1'-0" 18" 1'-0" 6" 18" 4- #6 CONT. ACROSS NEW TRANSVERSE BEAM 18" 18" 18" 3" CLR. NEW BEAM BEYOND 2" CLR. BEAMS 2" CLR. 6" CLR. 6" CLR. NEW FACE OF PILE 1 1/2" CLR 0" CLR 2'-0" #6 LAP ROUGHEN EDGE EXISTING SLAB 1'-10" 8" 37'-0" SECTION SCALE: 3/4" = 1'-0" A S-102 REINFORCING SECTIONS SHEET 2 OF 2 DRAWN : : S-104

9 BUMPER DAMAGE 15 5'-0" D S LIMITS OF MAJOR DAMAGE. SEE DETAIL 1 C S ELEVATION SCALE: 3/32" = 1'-0" 37'-0" B S A S '-0" 10 DETAIL SCALE: 1/2" = 1'-0" 1 S-105 LEGEND: SAWCUT AND DEMO EXISTING BEAM AND DECK. SEE S-101 FOR LIMITS OF SAWCUT LIMITS OF CONCRETE AND REBAR REMOVAL DRAWN : : PILE 15 PILE 14 PILE 13 PILE 14 PILE 13 PILE 12 LIMITS OF CONCRETE REMOVAL PILE 12 PILE 11 PILE 11 PILE 10 PILE 10 PILE 19 PILE 18 PILE 17 PILE 16 PILE 15 DOCK ELEVATION S-105

10 * 2'-6" 5'-6" 8'-6" LIMITS OF DAMAGE 24" PRESTRESSED CONCRETE PILES (TYP) 22'-0" PILE 11 - SECTION SCALE: 1/4" = 1'-0" A S-105 LEGEND: DRAWN : : LIMITS OF COMPLETE REMOVAL * = FIELD VERIFY, DIMENSIONS ARE APPROXIMATE * 8'-6" 7'-6" LIMITS OF CONCRETE REMOVAL (REBAR TO REMAIN) LIMITS OF DAMAGE PILE 11 - PHOTOS 2'-6" 24" PRESTRESSED CONCRETE PILES (TYP) 22'-0" PILE 12 - SECTION SCALE: 1/4" = 1'-0" B S-105 PILE 12 - PHOTOS PILE 11 AND PILE 12 DAMAGE PHOTOS S-106

11 2'-6" * 6'-0" 8'-6" LIMITS OF DAMAGE 24" PRESTRESSED CONCRETE PILES (TYP) 22'-0" PILE 13 - SECTION SCALE: 1/4" = 1'-0" C S-105 LEGEND: DRAWN : : * = FIELD VERIFY, DIMENSIONS ARE APPROXIMATE * 6'-6" LIMITS OF COMPLETE REMOVAL LIMITS OF CONCRETE REMOVAL (REBAR TO REMAIN) 8'-6" LIMITS OF DAMAGE PILE 13 - PHOTOS 2'-6" 24" PRESTRESSED CONCRETE PILES (TYP) 22'-0" PILE 14 - SECTION SCALE: 1/4" = 1'-0" D S-105 PILE 14 - PHOTOS PILE 13 AND PILE 14 DAMAGE PHOTOS S-107

12 COVER SHEET DRAWN : : R-100

13 R-101 VICINITY AND LOCATION MAP : DRAWN : NO. ISSUE FOR BIDDING REVISION

14 R-102 GENERAL NOTES, SYMBOLS AND ABBREVATIONS : DRAWN : NO. ISSUE FOR BIDDING REVISION

15 NEEDLE GIRDER STORAGE PLATFORM (1 OF 2) DRAWN : : R-103

16 NEEDLE GIRDER STORAGE PLATFORM (2 OF 2) DRAWN : : R-104

17 R-105 NEEDLE GIRDER STORAGE PLATFORM PLAN : DRAWN : NO. ISSUE FOR BIDDING REVISION

18 NEEDLE GIRDER PLATFORM MASONRY PLAN DRAWN : : R-106

19 NEEDLE GIRDER STORAGE PLATFORM REINFORCEMENT SECTIONS (1 OF 2) DRAWN : : R-107

20 R " CONCRETE PILE DETAILS : DRAWN : NO. ISSUE FOR BIDDING REVISION

21 FUEL LINE TIE-IN DETAIL AT BRIDGE AND NEEDLE GIRDER STORAGE PLATFORM DRAWN : : R-109

22 BERTHING FENDER AND LADDER DETAILS (1 OF 2) DRAWN : : R-110

23 BERTHING FENDER AND LADDER DETAILS (2 OF 2) DRAWN : : R-111

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

Section 2100-Trenching and Tunneling

Section 2100-Trenching and Tunneling SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial

More information

Chapter. Restoration of Damaged Structures

Chapter. Restoration of Damaged Structures 5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

Safe & Sound Bridge Terminology

Safe & Sound Bridge Terminology Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries

More information

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug. P-5 The P-5 is hot forged from carbon steel. The formed head provis spherical seating that the Lifting Eye engages, while a disc-shaped foot is embedd in the concrete. Due to its being a forged part, the

More information

Detailing of Reinforcment in Concrete Structures

Detailing of Reinforcment in Concrete Structures Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For

More information

Residential Decks. Planning and Development Services Department

Residential Decks. Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks

More information

Design and Construction of Cantilevered Reinforced Concrete Structures

Design and Construction of Cantilevered Reinforced Concrete Structures Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

SECTION 02845 GUARDRAILS

SECTION 02845 GUARDRAILS SECTION 02845 GUARDRAILS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals necessary and repair, replace or install all types of guardrails as specified herein

More information

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL. STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill

More information

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection

More information

Tension Development and Lap Splice Lengths of Reinforcing Bars under ACI 318-02

Tension Development and Lap Splice Lengths of Reinforcing Bars under ACI 318-02 ENGINEERING DATA REPORT NUMBER 51 Tension Development and Lap Splice Lengths of Reinforcing Bars under ACI 318-02 A SERVICE OF THE CONCRETE REINFORCING STEEL INSTITUTE Introduction Section 1.2.1 in the

More information

2006-2008 MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS

2006-2008 MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS 2006-2008 MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS GENERAL 10/16/2008 The listed average unit prices are based on the

More information

TORO STEEL BUILDINGS. BOLTS: o - 0.635" diam. x - 0.75 " diam. x - 1.00 " diam. C.J. - Control Joints to minimize cracking.(0.

TORO STEEL BUILDINGS. BOLTS: o - 0.635 diam. x - 0.75  diam. x - 1.00  diam. C.J. - Control Joints to minimize cracking.(0. 100 ' 0 " out to out of steel C 1 ' 3.25 " B Keep This Distance 37 ' 5.5 " ll sections and bolts have been blown up for clarification of placement. They are to be centered as much as possible on pier.

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE 9.1 INTRODUCTION An important reason that composite piles have not gained wide acceptance in the civil engineering practice is the lack of a long

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Uncovered Decks & Porches

Uncovered Decks & Porches Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

Preliminary Design Report Clay County, Florida Carpet n Drapes Culvert Repair and Rehabilitation July 21, 2006

Preliminary Design Report Clay County, Florida Carpet n Drapes Culvert Repair and Rehabilitation July 21, 2006 Clay County, Florida Carpet n Drapes Culvert Repair and Rehabilitation July 21, 2006 1.0 Background and Repair and Rehabilitation Recommendation Clay County has contracted Camp Dresser & McKee Inc. (CDM)

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

WILDCAT CANYON ROAD SPECIFICATION NO. 16-11001 SLIDE REPAIR BIDDER'S PROPOSAL (continued)

WILDCAT CANYON ROAD SPECIFICATION NO. 16-11001 SLIDE REPAIR BIDDER'S PROPOSAL (continued) BIDDER'S PROPOSAL (continued) Item Estimated No. Description Quantity Unit Unit Cost Total Cost BASE BID 1 Traffic Control 1 LS $ $ 2 Construction Area Signs 1 LS $ $ 3 Excavation Safety 1 LS $ $ 4 Reset

More information

COLORADO MODEL. 35 x 65 SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square

More information

SECTION 1 GENERAL REQUIREMENTS

SECTION 1 GENERAL REQUIREMENTS Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors. SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION

More information

SECTION 02400 - STORM DRAIN SYSTEM

SECTION 02400 - STORM DRAIN SYSTEM SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

SWIMMING POOL, SPA, & HOT TUB GUIDELINES SWIMMING POOL, SPA, & HOT TUB GUIDELINES Pool permit cost is based on the total value of the project. See Permit Fee Schedule Table 1A. A. Adopted construction codes and installation requirements 1. 2015

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and

More information

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14 Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318

More information

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION General 7 www.meadowburke.com 877-518-7665 MB1109 CONCRETE FLOOR SLAB AND CASTING BED CONSTRUCTION Quality Construction Begins at Ground Level Everything

More information

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL 7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction

More information

ATLANTA MODEL SPECIFICATIONS

ATLANTA MODEL SPECIFICATIONS ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet

More information

1.0 INDEX TO SHEETS URGENT STORM DAMAGE REPAIR AVON PARK AIR FORCE RANGE LOCATION MAP LEGEND LOCATION MAP

1.0 INDEX TO SHEETS URGENT STORM DAMAGE REPAIR AVON PARK AIR FORCE RANGE LOCATION MAP LEGEND LOCATION MAP 5 INDEX TO SHEETS. NOTES AND TYPICAL SECTIONS. H. R. SMITH RD.CULVERT.3 0/5 END BARRIER ACCESS ROAD REPAIR. KISSIMMEE RD. AT MORGAN HOLE CR. ROAD REPAIR.5 RANGE INFRASTRUCTURE REPAIR N 0 000' 3 0,000'

More information

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS. Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION

More information

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use

More information

SECTION 03300 CAST-IN-PLACE CONCRETE

SECTION 03300 CAST-IN-PLACE CONCRETE SECTION 03300 PART 1 GENERAL 1.01 DESCRIPTION This section describes materials and methods for formwork, reinforcement, mixing, placement, curing and repairs of concrete, and the use of cementations materials

More information

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final

More information

Wisconsin Building Products Evaluation

Wisconsin Building Products Evaluation Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation

More information

Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com

Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,

More information

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3. Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with

More information

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING Revised October, 2013 TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 REQUIRED DRAWINGS... 3 2.1 Site Plan... 3

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

PRE INSTALLATION MANUAL

PRE INSTALLATION MANUAL REINFORCED CONCRETE PIPE PRE INSTALLATION INSPECTION & REPAIR MANUAL Kentucky Transportation Cabinet Kentucky Department of Highways Division of Materials 1227 Wilkinson Boulevard Frankfort, KY 40601 (502)

More information

During severe flood events, such as those

During severe flood events, such as those Recommended Practice for Home Heating Oil Tank Flood Resistance During severe flood events, such as those occurring from Hurricane Irene and Super- Storm Sandy, many coastal and low elevation inland areas

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

No allowance will be made for classification of different types of material encountered.

No allowance will be made for classification of different types of material encountered. PROJECT : Repair/ Maintenance of Flood Control and Drainage Structures Along Butuan City Cagayan de Oro City Iligan City Road LOCATION : San Antonio, Jasaan, Misamis Oriental SUBJECT : General Notes and

More information

Joist. Reinforcement. Draft 12/7/02

Joist. Reinforcement. Draft 12/7/02 Joist Reinforcement Draft 12/7/02 1 JOIST REINFORCING The purpose of this CSD Design Aid is to provide procedures and suggested details for the reinforcement of open web steel joists. There are three basic

More information

US 51 Ohio River Bridge Engineering and Environmental Study

US 51 Ohio River Bridge Engineering and Environmental Study US 51 Ohio River Bridge Engineering and Environmental Study ITEM NOS. 1-100.00 & 1-1140.00 Prepared by: Michael Baker Jr., Inc. 9750 Ormsby Station Rd Louisville, KY 40223 August 16, 2013 Table of Contents

More information

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level

More information

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager Strengthening and Repair of Reinforced Concrete Structures Ian Wienholt Business Development Manager 34 years of Concrete Repair and Strengthening Experience Over 12,000 Repair Project Over 25,000 PT Projects

More information

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C. Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: [email protected] Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering

More information

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards

More information

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE... Starting Guide TABLE OF CONTENTS INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE... 7 ADVANCE CONCRETE USER INTERFACE... 7 Other important

More information

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 00 REVISED JANUARY 8, 008 Prepared in cooperation with the Building Inspectors Association of Southeastern Wisconsin www.biasew.org. /6/00 rev. 0/08/008

More information

APE T CFRP Aslan 500

APE T CFRP Aslan 500 Carbon Fiber Reinforced Polymer (CFRP) Tape is used for structural strengthening of concrete, masonry or timber elements using the technique known as Near Surface Mount or NSM strengthening. Use of CFRP

More information

SECTION 15410 GROUND WATER STORAGE TANKS

SECTION 15410 GROUND WATER STORAGE TANKS SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design

More information

How to secure your property after a disaster

How to secure your property after a disaster How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,

More information

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant

More information

September 1, 2003 CONCRETE MANUAL 5-694.900 CONCRETE PAVEMENT REHABILITATION 5-694.900

September 1, 2003 CONCRETE MANUAL 5-694.900 CONCRETE PAVEMENT REHABILITATION 5-694.900 September 1, 2003 CONCRETE MANUAL 5-694.900 5-694.901 GENERAL CONCRETE PAVEMENT REHABILITATION 5-694.900 Concrete Pavement Rehabilitation is an extremely valuable tool of the Minnesota Department of Transportation

More information

Structural Failures Cost Lives and Time

Structural Failures Cost Lives and Time Structural Failures Cost Lives and Time Recent failures of storage bins, silos and other structures highlight the need to increase awareness of hazards associated with these structures. Since 2010, one

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall

More information

DIVISION 4300 STORM DRAINAGE

DIVISION 4300 STORM DRAINAGE DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES

More information

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR

More information

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with

More information

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS Section Page 36-1 GENERAL... 36.1 36-2 PIPEMAKING EQUIPMENT... 36.1 36-3 TRENCH EXCAVATION... 36.1 36-4 SPECIAL FOUNDATION TREATMENT...

More information

The unit costs are based on the trend line of the 3 low bids for the average quantity.

The unit costs are based on the trend line of the 3 low bids for the average quantity. Page 1 of 8 COST ESTIMATE GENERAL INSTRUCTIONS The unit costs are based on the trend line of the 3 low bids for the average quantity. Apply the Unit Costs to ordinary structures. Unit Costs should generally

More information

Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12)

Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Design Criteria AASHTO LRFD Bridge Design Specifications, 6th Edition; Structures Detailing Manual (SDM); Structures Design Guidelines (SDG)

More information

1 Barlines Rebar Detailing Standards in the Philippines

1 Barlines Rebar Detailing Standards in the Philippines Barlines Rebar Detailing Standards in the Philippines METRIC (SI), STANDARD HOOKS AND OTHER DETAILING CRITERIAS By Amadeus (Mady) Magpile, President and CEO INTRODUCTION This is first in a series of articles

More information

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations Nathan A. Ingraffea, P.E., S.E. Associate, KPFF Consulting Engineers, Portland, Oregon, USA Abstract The use of steel sheet

More information

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1 Chapter 5 Bridge Deck Slabs Bridge Engineering 1 Basic types of bridge decks In-situ reinforced concrete deck- (most common type) Pre-cast concrete deck (minimize the use of local labor) Open steel grid

More information

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04 BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and

More information

Gas Meter Clearances and Service Installation Requirements

Gas Meter Clearances and Service Installation Requirements March 2015 Gas Meter Clearances and Service Installation Requirements Builder/Owner/Developer Requirements Call PSE s Customer Construction Services 1-888-321-7779 or visit PSE.com/CustomerConstruction

More information

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional

More information

Section 402. STORM SEWERS

Section 402. STORM SEWERS 402.02 Section 402. STORM SEWERS 402.01. Description. This work consists of constructing storm sewers of the size and class required, including excavation, bedding, and backfill. 402.02. Materials. Provide

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE 2/2013 ANCHOR BOLTS INSTRUCTIONS FOR USE - Threaded rebars ATP, AHP, AJP - Threaded high strength steel bolts ALP-L, ALP-P, AMP ATP AHP ALP-L ALP-P AMP Eurocode design according to EN1993-1-8 (2005) &

More information

Basics of Reinforced Concrete Design

Basics of Reinforced Concrete Design Basics of Reinforced Concrete Design Presented by: Ronald Thornton, P.E. Define several terms related to reinforced concrete design Learn the basic theory behind structural analysis and reinforced concrete

More information

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA 30548 LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room.

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA 30548 LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room. 1.d 2.d 3.d 4.d 1.d 2.d 3.d 4.d REMOVE, REPAIR, & REPLACE EXISTING STOREFRONT SYSTEMS D.1 D.2 REMOVE, REPAIR, & REPLACE EXISTING STOREFRONT SYSTEMS D.1 D.2 REMOVE STAIR & INFILL WALL C.1 REMOVE DOOR &

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

SECTION 3 SANITARY SEWER DESIGN

SECTION 3 SANITARY SEWER DESIGN SECTION 3 SANITARY SEWER DESIGN 3.1 GENERAL DESIGN CRITERIA 3.1.1 Requirement for Sanitary Sewer 3.1.2 Design Approval 3.1.3 IEPA Permit Required 3.1.4 Differentiation Between Public and Private Sanitary

More information

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of

More information

STANDARD OPEN PATIO COVER

STANDARD OPEN PATIO COVER STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist

More information

Item No. 432S Portland Cement Concrete Sidewalks. 432S.1 Description

Item No. 432S Portland Cement Concrete Sidewalks. 432S.1 Description Item No. 432S Portland Cement Concrete Sidewalks 432S.1 This item shall govern the construction of Portland cement concrete sidewalks (Standard Detail No. 432S-1), as herein specified, on an approved subgrade

More information

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm: Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section

More information