PART C MATERIAL SPECIFICATIONS
|
|
|
- Kristina Lamb
- 10 years ago
- Views:
Transcription
1 REGION OF WATERLOO AND AREA MUNICIPALITIES DESIGN GUIDELINES AND SUPPLEMENTAL SPECIFICATIONS FOR MUNICIPAL SERVICES PART C
2 TABLE OF CONTENTS C.1 GENERAL... 1 C.1.1 Ontario Provincial Standards... 1 C.1.2 Definitions... 1 C.1.3 Standards Council of Canada... 1 C.1.4 Material Conformance... 1 C.2 WATERMAIN... 2 C.2.1 Watermain Pipe... 2 C Ductile Iron Pipe... 2 C Concrete Pressure Pipe... 2 C Polyvinyl Chloride Pipe (PVC)... 3 C High Density Polyethylene Pipe (HDPE)... 4 C.2.2 Valves... 5 C Gate Valves... 5 C Combination Air and Vacuum Release Valvesas soon as possible6 C.2.3 Tapping Sleeves... 6 C.2.4 Valve Chambers... 6 C Cast Iron Maintenance Hole Lids... 6 C Adjustment Units... 6 C Safety Post... 6 C.2.5 Line Closure Couplings... 7 C.2.6 Flange Adaptors... 7 C.2.7 Valve Boxes... 7 C.2.8 Hydrants... 7 C mm And Smaller Service Connections... 8 C Service Pipe... 8 C Minimum Size... 8 C Service Saddles... 8 C PVC Tapped Couplings... 8 C Main Stops... 9 C Union Couplings... 9 C Curb Stops... 9 C Service Boxes... 9 i
3 C.2.10 Temporary Watermains... 9 C.2.11 Metal Items C Bolts, Nuts and Washers C Cast Iron C Galvanizing C.2.12 Petrolatum Tape Systems C.2.13 Anodes C.2.14 Tracer Wire C.2.14 Warning Tape C.3 SEWERS C.3.1 Pipe Materials C Concrete Sewer Pipe and Fittings C PVC Sewer Pipe and Fittings C HDPE Sewer Pipe and Fittings C Approved Sanitary Sewer Pipe Materials C Sanitary Forcemain Material C Approved Storm Sewer Pipe Materials C.3.2 Cast Iron Maintenance Hole Lids C.3.3 Cast Iron Catchbasin Frames and Grates C.3.4 Maintenance Hole and Catchbasin Adjustment Units C.3.5 Slotted Pipe Drain C.3.6 Flexible Couplings C.3.7 Watertight Connectors ii
4 C.1 GENERAL C.1.1 ONTARIO PROVINCIAL STANDARDS The Region of Waterloo and Area Municipal Design Guidelines and Supplemental Specifications for Municipal Services (DGSSMS) are supplemental to the Ontario Provincial Standards (OPS) and thus take precedence over the related specifications (OPSS s) and drawings (OPSD s). C.1.2 C DEFINITIONS Approved Equivalent: shall mean written approval for installation by the Chief Municipal Engineer on a project by project basis. C.1.3 STANDARDS COUNCIL OF CANADA All materials approved to CSA international standards shall be supplied from a plant approved by an organization accredited by the Standards Council of Canada. C.1.4 MATERIAL CONFORMANCE All materials shall be certified to the latest revised applicable specifications of the American Waterworks Association (AWWA), American Society for Testing and Materials (ASTM), National Sanitation Foundation (NSF) 14 & 61, American National Standard Institute (ANSI), Underwriters Laboratory (UL), American Association of State Highway and Transportation Officials (AASHTO) and the Canadian Standards Association (CSA). Certification to be provided to Municipality, as referenced in the following sections. On a project specific basis, the Contractor may apply to have a product considered approved equivalent for any of the product categories listed in the following sections. C1
5 C.2 WATERMAIN C.2.1 WATERMAIN PIPE C Ductile Iron Pipe C Manufacture Ductile iron pipe shall be manufactured in accordance with AWWA C151/A21.51 and shall be cement lined in accordance with AWWA C104/A21.4. Ductile iron pipe shall be designed in accordance with AWWA C150/A21.50 and shall be minimum thickness Class 52. Ductile iron pipe shall have bell and spigot rubber gasket joints manufactured in accordance with AWWA C111/A Copper bonding straps shall be supplied with bell and spigot joints to maintain electrical conductivity from pipe to pipe. C Fittings Fittings shall be grey or ductile iron conforming to AWWA C110/A21.10 or compact ductile iron conforming to AWWA C153/A Fittings shall have mechanical joint ends conforming to AWWA C111/A21.11 unless otherwise specified and shall be cement lined in accordance with AWWA C104/A21.4. Cast iron fittings shall only be used for main sizes where compact ductile iron fittings are not available. Copper bonding straps shall be used to maintain electrical conductivity. Where flanged fittings are specified, gaskets shall be 3 mm thick full face rubber. C Joint Restraint Joint restraints for ductile iron pipe shall be wedge action type meeting the requirements of AWWA C-111 where appropriate, and be listed by ULc or FM. Accepted products include EBAA(Series 1100), Romac (RomaGrip), Sigma (One Lok SLD, SLDH, SSLD), Star (Stargrip3000, 3100P, 3000OS), Clow MJ Field Lok and UniFlange (Series 1400, 1450). C Concrete Pressure Pipe C Manufacture Concrete pressure pipe shall be manufactured in accordance with AWWA standards C301 and C303 for pipe diameters up to 500 mm. Use AWWA C301 for pipe diameters 600 mm and. C Fittings Fittings shall be manufactured in accordance to AWWA Standard C301 and C303. C2
6 C Joints Concrete pressure pipe and fittings shall be jointed using rubber gaskets, and approved joints as outlined in the manufacturer's installation guide and AWWA Standards C301 and C303. All joints shall be protected on the exterior using diapers and grout. C Thrust Restraint Thrust restraint shall be provided through the use of restraining joints approved and supplied by the manufacturer. C Polyvinyl Chloride Pipe (PVC) C Manufacture Polyvinyl chloride (PVC) pressure pipe shall be manufactured to cast iron outside diameters. PVC pipe shall be colour coded blue and shall have an integral wall-thickened bell designed for joint assembly using an elastomeric gasket conforming to ASTM D3139. PVC pipe sizes 100 mm through 300 mm shall be minimum DR18, conform to AWWA C900 and be certified to CSA B PVC pipe in sizes 350 mm and shall be minimum DR25, conform to AWWA C905 and be certified to CSA B C Fittings Non-Metallic Non-metallic Fittings for 100, 150 and 200 mm PVC pipe shall be injection moulded with push on gasketed joints, conform to AWWA C-907 and shall be certified to CSA B Fittings for 250 mm and PVC pipe shall be fabricated from PVC pipe that is certified to CSA B Fittings 250 mm and 300 mm shall be one piece construction or manufactured from segments of AWWA C900 PVC pipe, bonded together and over-wrapped with fibreglass reinforced polyester to meet the requirements of the standard. Fittings 350 mm to 900 mm shall be one piece construction or manufactured from segments of AWWA C905 PVC pipe bonded together and over-wrapped with fibreglass reinforced polyester to meet the requirements of the standard. The pressure ratings of the fabricated fittings shall match the pressure ratings of the pipe. Metallic Fittings shall be grey or ductile iron conforming to AWWA C110/A21.10 or compact ductile iron conforming to AWWA C153/A Fittings shall have mechanical joint ends conforming to AWWA C111/A21.11 unless otherwise specified and shall be cement lined in accordance with AWWA C104/A21.4. Cast iron fittings shall only be used for main sizes where compact ductile iron fittings are not available. C3
7 C Joint Restraints Serrated (machined) ring type joint restraints for PVC pipe shall meet the requirements of Uni- Bell B-13 or ASTM F1674, and AWWA C-111 where appropriate, and be listed by ULc or FM. Accepted products include Clow (Series 300, 350, 360), EBAA (Series 1600, 2500, 2800), Sigma (PV Lok PVP, PVM, PVPF), Star (Stargrip 1000, 1100, 1200), Clow MJ Field Lok and UniFlange (Series 1300, 1350, 1360). Serrated ring type joint restraints for PVC pipe will not be permitted in the Township of Woolwich. Wedge action type joint restraints for PVC pipe shall meet the requirements of Uni-Bell B-13 or ASTM F1674, and AWWA C-111 where appropriate, and be listed by ULc or FM. Accepted products include EBAA (Series 2000PV), Sigma (One Lok SLC), Star (Stargrip 4000,4100P) and UniFlange (Series 1500). C Polyvinyl Chlorine Orientated (PVCO) C Manufacture Bionax PVCO CIOD Watermain Pressure Pipe (100mm through 300mm) Molecularly oriented PVC pipe in sizes 100mm (4 ) through 300mm (12 ) shall be Biaxially Oriented (molecular orientation in two directions), third party certified to AWWA C909 and third party certified to NSF 61 for potable water use. The pipe shall have Cast Iron Outside Diameters (CIOD). Be colour coded blue and have a Pressure Class of 235 psi. Bionax PVO IPSOD forcemain pressure (100mm through 300mm) Molecularly oriented PVC pipe in sizes 100mm (4 ) through 300mm (12 ) shall be Biaxially Oriented (molecular orientation in two directions), conforming to ASTM F1483 and third party certified to NSF 61 for potable water use. The pipe shall have Cast Iron Outside Diameters (CIOD). Be colour coded blue and have a Pressure Class of 160 psi. C Fittings PVCO Pipe to Injection Moulded Fittings (tees, bends, etc) 100mm (4 ) to 200mm (8 ): EBAA Iron Series 2500, Sigma PV-LOK Model PVPF, Uni-Fange Series PVCO Pipe to PVC Fabricated Fittings (tees, bends, etc) 100mm (4 ) to 300mm (12 ):EBAA Iron Series 2500, Uni-Flange Series PVCO Pipe Standard Bell-and-Spigot Push-On Joints 100mm (4 ) to 300mm (12 ): Sigma PV- LOK model PVP. PVCO Pipe to Mechanical-Joint Fitting 100mm (4 ) to 300mm (12 ):EBAA MEGALUG Series 2000PV, Sigma PV-LOK model PVM, Star PVC Grip Series 4000, Uni-Flange Series C4
8 C High Density Polyethylene Pipe (HDPE) C Manufacture Where high density polyethylene (HDPE) pressure pipe is specified and approved by the Chief Municipal Engineer for situations of specialized installation, it shall be ductile iron pipe outside diameter, co-extruded blue or blue stripe in colour, and meet the requirements of OPS 701. C Fittings HDPE pipe fittings shall meet the requirements of OPS 701. C Joint Restraints Joints will be restrained in accordance with OPS 701. C.2.2 VALVES C Gate Valves For valves equal to and less than 300mm: Gate valves shall be resilient wedge conforming to AWWA C509. For valves greater than 300mm: Gate valves shall be either double disk conforming to AWWA C500or resilient wedge conforming to AWWA C509 or AWWA C515. In the City of Cambridge, valves greater than 300mm are to be double disk with 75 mm bypass; valve box must accommodate the bypass and gear reducer. On the Region of Waterloo projects, located in Cambridge, valves greater than 300 mm shall be double disk. Resilient wedge valves shall be Mueller or Clow. The City of Cambridge also accepts McCoy East Jordan Iron Works Flowmaster for resilient valves not greater than 300mm. Double disk valves shall be Clow or Mueller. All gate valves shall be iron body, bronze mounted with inside screw, non-rising spindle and a 50 mm operating nut that opens by turning counter-clockwise. Gate valves in sizes 100 mm to 350 mm shall have mechanical joint ends. Gate valves in sizes 400 mm and shall have a 75 mm integral bypass, mechanical joint or flanged ends, waterproof spur gearing and shall be supplied with a shop drawing. In the City of Guelph double disk valves supplier shall be Clow only. For 400 mm gate valves no spur gearing is required and shall conform to AWWA C515 Ductile Iron. Gate valves in sizes 450 mm and shall have an integral bypass, mechanical joint or flanged ends, waterproof spur gearing and shall be supplied with a shop drawing. C5
9 C Combination Air and Vacuum Release Valves Combination air and vacuum release valves shall consist of an air and vacuum valve and an air release valve in a single body housing. The body and cover shall be cast iron conforming to ASTM A126 Class B. Combination air and vacuum release valves shall be Golden Anderson Industries (Figure GA945). C.2.3 TAPPING SLEEVES Carbon steel tapping sleeves shall be Smith-Blair 622, Mueller H-615, Ford FTSC. Carbon steel tapping sleeves shall have fusion bonded epoxy finish and come equipped with TYPE 304 stainless steel bolts, nuts and washers. Stainless steel tapping sleeves shall be Ford FAST, Smith-Blair 663, Mueller H304. Stainless steel tapping sleeves including flanges shall be manufactured from Type 304 stainless steel and shall come equipped with Type 304 stainless steel bolts, nuts and washers C.2.4 VALVE CHAMBERS C Cast Iron Maintenance Hole Lids Cast iron maintenance hole lids shall be as per OPSS 1850 and OPSD as manufactured by Bibby, McCoy. C Adjustment Units Concrete adjustment units shall be as per OPSS 407 and OPSD Precast adjustment units shall be laid in a full bed of mortar with successive units being joined using sealant as recommended by the manufacturer. A minimum of one (1) adjustment unit shall be installed with a minimum height of 75mm. A maximum of four adjustment units may be installed to a height not in excess of 300 mm. Concrete brick and mortar shall not be used. Rubber adjustment units as per OPSS 1853 or HDPE as per OPSS 1854, as manufactured by IPEX under the trade name Lifesaver. C Safety Post Safety posts shall be galvanized "Ladder Up" as manufactured by "BILCO", MSU Model C6
10 C.2.5 LINE CLOSURE COUPLINGS Line closure coupling shall be Robar Style 1408 (Robar is not accepted in Kitchener), Smith- Blair Style 411, Mueller Viking Johnson Maxifit, Hymax C.2.6 FLANGE ADAPTORS Flange adapters shall be Uni-Flange Series 400 or 900, Clow Series 40 and 90, EBAA Iron Megaflange Series 2100, Smith-Blair l Series 913. C.2.7 VALVE BOXES Cast iron valve boxes shall be a screw type box with a No. 6 Base as supplied by Bibby, Mueller or Star. Lid shall read WATER or large W. The valve box must be raised to final grade, road levellers are not to be used in the City of Kitchener. C.2.8 HYDRANTS Hydrants shall conform to AWWA C502 for Dry Barrel Hydrants and shall open counter clockwise (clockwise in the City of Guelph) by a 32 mm square operating nut. Hydrants shall have tapped drain ports, 150 mm mechanical joint inlet with brass to brass fittings on the main valve seat, two 63.5 mm (2.5 in) hose nozzles spread 180 degrees apart and a mm (4.5 in) pumper nozzle with a 100 mm ULC approved Stortz connection. Hydrants shall be connected to the main using 150 mm lead, 150 gate valve and anchor tee. Hydrants shall be supplied for a minimum 2.3 m depth of trench. A maximum of one hydrant extension (300 mm or less for new development) shall be allowed, with authorization of the Chief Municipal Engineer, between the upper and lower hydrant barrels for deeper installations. Hydrants barrels shall be painted chrome yellow with a high gloss exterior paint over a quick dry oxide primer. Stortz nozzles shall be painted black. The colour(s) of hydrant bonnet and nozzle caps shall be obtained from the Chief Municipal Engineer and painted with a high gloss exterior paint over a quick dry oxide primer. In the City of Kitchener (including Regional s projects), and the City of Guelph the watermain diameter in inches to which the hydrant is connected shall be painted in black letters 200 mm high on the face of the hydrant barrel immediately below the pumper nozzle. Hydrants shall be either Canada Valve (Century), Mueller (Modern Centurian), or Clow (Brigadier). (City of Cambridge permits McCoy Construction Castings hydrants and McCoy East Jordan Iron Works Watermaster). In the Township of Woolwich all hydrants shall be Canada Valve (Century). C7
11 In the City of Guelph all hydrants shall be McAvity style M-67 and Darling Century. C MM AND SMALLER SERVICE CONNECTIONS C Service Pipe Copper service pipe for services 50 mm and smaller shall be Type K soft copper and shall conform to ASTM B88. Polyethylene service pipe for services 50 mm and smaller shall be certified to CSA B137.1 minimum Series 160. Composite pipe for services 19 and 25 mm in diameter shall be certified to CSA B137.9 and shall be as manufactured by IPEX under the trade name Q-Line. Blue 904-PEX and Municipex municipal water service tubing for services 50mm and smaller shall be certified to AWWA C904, CSA B137.5 and NSF 14 and 61. All service pipes shall be of new manufacture. Kinked, crushed or distorted tubing will not be accepted. All service piping in the City of Guelph shall be copper. C Minimum Size The minimum nominal service size shall be 25mm except in the Townships of North Dumfries and Wilmot, and the Cities of Cambridge and Guelph where the minimum size is 19mm. Polyethylene service pipe shall be minimum 25 mm in the City of Cambridge C Service Saddles Saddles shall be 18 gauge Type 304 stainless steel with AWWA tapered thread. Saddles for PVC pipe shall be double bolted. Saddles shall have a minimum of 50 mm bearing width and shall be fully contoured to the outside of the pipe. Service saddles shall be Cambridge Brass Series 403, Ford FS303, Romac and come equipped with TYPE 304 stainless steel bolts, nuts and washers. C PVC Tapped Couplings Tapped couplings are approved for use on PVC watermains. C8
12 C Main Stops Main stops shall be the same size as the service pipe and shall have AWWA tapered thread inlet and compression joint outlet. Main stops shall be equipped with electrical grounding tail nuts when required for connection of tracer wire and anodes for corrosion protection. Main stops shall be Cambridge Brass Series 302, Ford Series F1000, Mueller. C Union Couplings Union couplings shall have compression joints and shall be Cambridge Brass Series 118, Mueller Series, Ford Pack Joint C44 or Straub Tabco Inc. C Curb Stops Curb stops shall be the same size as the service pipe and shall be compression joint (CJ) inlet and (CJ) outlet. Curb stops shall be equipped with electrical grounding tail nuts for connection of tracer wire and anodes for corrosion protection. Curb stops shall be Cambridge Brass 202 Series, Mueller B Series or Ford B44 Series. In the City of Kitchener, curb stops shall be Cambridge Brass 202 Series, Mueller H Series or Ford B44 Series. Stop and drain type curb stops are not accepted in the City of Kitchener unless special approval is obtained by the Chief Municipal Engineer. C Service Boxes Service boxes shall be cast iron with a 25 mm upper section and shall have stainless steel rods and cotter pins. Service boxes shall be adjustable to between 1.8 metres and 2.1 metres to suit service depths. Service boxes shall be Mueller A-314 or A-726. C.2.10 TEMPORARY WATERMAINS All temporary distribution and service piping shall be certified for potable water use as per ANSI/NSF Standard 14 and Standard 61. The distribution piping shall be a minimum 50mm diameter, Aqua Mine high impact, ASTM PVC 1120, D2241, SDR17, 1720 kpa. Larger diameter may be required for fire protection. Service piping shall be minimum 19mm diameter Kuritec. C9
13 C.2.11 METAL ITEMS C Bolts, Nuts and Washers C Cor-Ten Cor-Ten T-head bolts, nuts and washers shall conform to the latest issue of ASTM and AWWA. C Zinc Coated Zinc coated bolts, nuts and washers shall conform to the latest issue of ASTM. Use Grade 2, Designated A 305 bolts for flanges up to and including 300 mm diameter and Grade 5, Designated A 307 for flanges than 300 mm diameter. C Cadmium Coated Cadmium coated bolts, nuts and washers shall conform to the latest issue of ASTM. Use Grade 2, Designated A 305 bolts for flanges up to and including 300 mm diameter and Grade 5, Designated A 307 for flanges than 300 mm diameter. C Stainless Steel Stainless steel bolts, nuts and washers shall be stainless steel Type 304 conforming to the latest issue of ASTM F593 and F594. C Cast Iron Cast Iron shall conform to ASTM Designation A-48, Class 30B, Standard Specifications for Grey Iron Castings. Cast iron products shall be asphalt coated. C Galvanizing Galvanizing shall conform to the standard specifications for ASTM Designation A Zinc Coatings on Structural Steel Shapes. Metal products specified as galvanized shall be galvanized after fabrication. C.2.12 PETROLATUM TAPE SYSTEMS Anti corrosion wrap shall be as supplied by Denso North America Inc. or Petro Coating Systems Ltd. Only material from one supplier exclusively shall be used on an installation. At no time shall materials from either system be utilized with the other. Denso coating material shall consist of Denso paste or Denso priming Solution (for cold temperature application), Denso Profiling Mastic or Denso Mastic Blanket, and Denso LT Tape. C10
14 PP Series Primer Paste, PM Series Mastic, LT/ST/Ht Petroleum Tape, PVC 250 Overwrap Tape from Petro Coating Systems Ltd. C.2.13 ANODES Packaged anodes shall be zinc Z (24lb) manufactured using a high purity zinc (99.99% pure zinc) conforming to ASTM B-418 Type II. The anode shall have an average current efficiency of 90% and provide an open circuit potential with a minimum 1.10 Volt D.C. as measured with respect to copper / copper sulphate reference electrode. The zinc casting shall have a minimum 3.2 mm (0.125 ) diameter galvanized steel core wire throughout its length and shall be packaged in a cardboard or cloth container approximately 100 mm in diameter. The depolarising material surrounding the zinc casting shall be composed of a gypsum/bentonite base material having an electrical resistivity less than 50 ohm/cm wet. An insulated copper wire (AWG #10/7 strand), 2m minimum in length shall be brazed to the end of the core wire. C.2.14 TRACER WIRE Tracer wire shall be #8 gauge TWU multi-strand copper. Splices and other wire to wire connections shall be made by soldering or using Dryconn #10999 waterproof connectors as shown on Drawing E2-15 or by using copper split bolt connectors. C.2.15 WARNING TAPE Warning tape for identification of non-potable watermains shall be 3.5 mil polyethylene underground warning tape, 75 mm wide, white letters on blue background as supplied by Seton Canada or approved equal. For raw watermains, wording shall be RAW water line and the warning tape shall be supplied by the Region for mains within the Region of Waterloo. C11
15 C.3 SEWERS C.3.1 PIPE MATERIALS Pipe materials for storm and sanitary sewer mainline, fittings and service laterals shall be certified by CSA international or accredited by the Standard Council of Canada (SCC). C Concrete Sewer Pipe and Fittings Circular concrete pipe and fittings shall conform to OPSS 1820 and shall be manufactured at a plant certified under the Ontario Concrete Plant Prequalification Program. Non reinforced concrete pipe shall be according to CSA A Reinforced concrete pipe shall be according to CSA A Precast reinforced concrete manhole shall be according the CSA A257.4.Joints and gaskets shall be according to CSA A C PVC Sewer Pipe and Fittings Circular PVC pipe and fittings complete with bell and spigot joints, rubber gasket, lubricant and all other necessary appurtenances shall be manufactured in conformance with OPSS 1841 and shall be certified to either CSA B182.2 or B182.7 for PVC Sewer Pipe and Fittings or CSA B182.4 for Profile PVC Sewer Pipe and Fittings. PVC pipe shall have a minimum pipe stiffness of 320 kpa. C HDPE Sewer Pipe and Fittings Circular PE pipe and fittings complete with bell and spigot joints, rubber gasket, lubricant and all other necessary appurtenances shall be manufactured in accordance with OPSS 1840 using virgin resin and shall be certified to CSA B182.6 for Profile Polyethylene Sewer Pipe and Fittings. Circular PE pipe and fittings shall have a minimum pipe stiffness of 320 kpa and 100 kpa gasketed joints. C HDPE Storm Sewer Pipe and Fittings Circular profile PE pipe shall be complete with bell and spigot joints, rubber gasket, lubricant and all other necessary appurtenances and shall meet the requirements of OPSS 1840 (latest revision) and be manufactured in accordance with CSA B182.8 Profile Polyethylene Storm Sewer and Drainage Pipe and Fittings (latest revision) using virgin resin and shall be certified to this standard by a product certification body accredited by the Standards Council of Canada (SCC). Circular profile PE pipe shall have a minimum pipe stiffness of 320 kpa and 74 kpa water tight gasket joints (Type 1). All fittings used for PE installation shall be PVC quality and certified to either CSA B182.2 for PVC Sewer Pipe and Fittings or CSA B182.4 for Profile PVC Sewer Pipe and Fittings. PVC pipe shall have a minimum pipe stiffness of 320 kpa. C12
16 C Approved Sanitary Sewer Pipe Materials Type of Pipe Specification Diameter Approved Use Approved Manufacturer Non- Reinforced Concrete CSA A257.1 Extra Strength 200mm to 250mm mainline Hanson Reinforced Concrete CSA A mm and mainline Hanson, Concast, Coldstream, Munro, Hyprescon, M-Con, Rainbow SDR 35 PVC CSA B182.2, 320 kpa Stiffness 200mm and mainline IPEX, Rehau, Royal SDR 35 PVC CSA B182.2, 320 kpa Stiffness 200mm and mainline IPEX (Enviro-Tite) SDR 28 PVC CSA B182.2, 625 kpa Stiffness 100mm and 150mm service laterals IPEX, Rehau, Royal SDR 28 PVC CSA B182.7, 625 kpa Stiffness 100mm and 150mm service laterals IPEX (Enviro-Tite) Profile Polyethylene CSA B kpa Stiffness 100mm and 150mm service laterals (requires approval from Chief Municipal Engineer) Armtec (Polytite) C Sanitary Forcemain Material Sanitary forcemain material shall be selected to suit the installation and system requirements and be pre-approved by the municipality. Under no circumstances shall the material selected for the forcemain be colour coded blue. C Approved Storm Sewer Pipe Materials Type of Pipe Specification Diameter Approved Use Approved Manufacturer Concrete CSA A257.1 Extra Strength 250 mm to 300 mm catchbasin lead and service connections Hanson 200 mm to 300 mm service connections Hanson C13
17 Type of Pipe Specification Diameter Approved Use Approved Manufacturer Concrete CSA A257.2 Reinforced 300 mm and mainline and service connections Hanson, Concast, Coldstream, Munro, Hyprescon, M-Con, Rainbow SDR 35 PVC CSA B kpa Stiffness 200 mm and Mainline, catchbasin lead and service connections IPEX, Rehau, Royal SDR 35 PVC CSA B kpa Stiffness 200 mm and Mainline, catchbasin lead and service connections IPEX (Enviro-Tite) SDR 28 PVC CSA B kpa Stiffness 150mm service connections IPEX, Rehau, Royal SDR 28 PVC CSA B kpa Stiffness 150mm service connections IPEX (Enviro-Tite) Profile HDPE CSA kpa stiffness watertight gasket min 75 kpa, PVC fittings to be used 300mm 525mm Mainline ADS Hancor (not approved in the City of Guelph) Profile PVC CSA B kpa Stiffness 200 mm and service connections IPEX, Rehau, Royal 250 mm and mainline and catchbasin lead IPEX, Rehau, Royal Profile HDPE CSA B kpa Stiffness 200 mm and service connections Armtec (Polytite) Ideal Challenger mm and mainline and catchbasin lead Armtec (Polytite) Ideal Challenger 3000 C14
18 Note: The Region of Waterloo will not accept plastic pipe over 600mm diameter. The City of Waterloo will not accept plastic pipe over 525mm. The Township of Wilmot will not accept plastic pipe over 375 mm diameter. The City of Cambridge and Township of Woolwich will not accept plastic pipe over 450 mm diameter. C.3.2 CAST IRON MAINTENANCE HOLE LIDS Cast iron maintenance hole lids shall be as per OPSS 1850 and OPSD Type A Closed Cover as manufactured by Bibby, McCoy or Star. In the City of Kitchener Type B Cover is to be used for storm sewer applications. C.3.3 CAST IRON CATCHBASIN FRAMES AND GRATES Cast iron catchbasin frames and grates shall conform to OPSS 1850 and shall be manufactured by Bibby, McCoy or Star. Catchbasin frames and grates shall be as per: OPSD in the City of Cambridge ; OPSD in the City of Guelph; OPSD in the City of Kitchener; SSMS E4-01 in the City of Waterloo and Township of Woolwich; SSMS E4-03 and E4-041 and E4-042 on Region of Waterloo roadways; or, as directed by the Municipality C.3.4 MAINTENANCE HOLE AND CATCHBASIN ADJUSTMENT UNITS Concrete adjustment units shall be as per OPSS 407 and OPSD Precast adjustment units shall be laid in a full bed of mortar with successive units being joined using sealant as recommended by the manufacturer. A minimum of one (1) adjustment unit shall be installed with a minimum height of 75mm. A maximum of four adjustment units may be installed to a height not in excess of 300 mm. Concrete brick and mortar shall not be used. Rubber adjustment units as per OPSS 1853 or HDPE OPSS 1854, as manufactured by IPEX under the trade name Lifesaver. The City of Cambridge will only accept concrete adjustment units confirming to OPSS 407. C15
19 C.3.5 SLOTTED PIPE DRAIN Slotted drain pipe shall be fabricated from galvanized steel in accordance with AASHTO M-36 and shall have a minimum wall thickness of 1.6 mm. Slotted drain pipe shall be as manufactured by Armtec. C.3.6 FLEXIBLE COUPLINGS Flexible couplings shall be as supplied by Fernco or Mission. C.3.7 WATERTIGHT CONNECTORS Watertight connectors shall be Kor-N-Seal. C16
Chapter 6 Material Specifications
Chapter 6 Material Specifications Chapter 6 Material Specifications Materials incorporated in the finished work and used during construction shall be according to the standards and specifications specified
08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
INDEX. Sec. No. Items Page Nos.
INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............
EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work
WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION
WATER MAIN CONSTRUCTION TECHNIQUES Overview Water Main - Materials Specifications Installation Future? Water Main Materials Material Types There are various material types used for water mains, these include:
SECTION 603 SANITARY SEWER FORCE MAINS
SECTION 603 SANITARY SEWER FORCE MAINS 1. GENERAL Pipelines for sanitary sewer force main systems shall conform to the following specifications and shall be installed at the locations indicated on the
Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011
STANDARDS AND CONSTRUCTION MANUAL : Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011 PART 1 - GENERAL 1.01 SCOPE OF WORK A. These specifications cover the pipes, fittings, and appurtenances
ENGINEER S LIST OF APPROVED ITEMS POTABLE WATER SYSTEM
ENGINEER S LIST OF APPROVED ITEMS POTABLE WATER SYSTEM General 1. All products must be NSF 61 approved for potable water service 2. All products with brass or bronze must be lead free 3. Advanced written
SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.
The following shall serve as the minimum requirements for contractors performing work in relation to the Authority s potable water and sanitary sewer system(s), appurtenances and service connections. General:
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES
SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections
SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL
SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL PART 1 - GENERAL 1.1 WORK INCLUDED IN THIS SECTION A. The WORK of this Section includes the repair, demolition, and disposal of asbestos
SECTION 33 12 19 FIRE HYDRANTS
SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE
Section C-1 Pipes and Fittings
Section C-1 Pipes and Fittings C1.00 Work Included The work under this Division of the Specifications shall include all labor, materials, and equipment necessary to furnish and install all piping, pipelines,
SECTION 02401 - SANITARY SEWER PIPE
PART 1 - GENERAL 1.1 DESCRIPTION A. The WORK under this Section includes providing all labor, materials, tools and equipment necessary for furnishing and installing sanitary sewer pipe, in accordance with
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer The user may choose to adopt part or all of this Model Specification; however, the user should ensure that all parts
SECTION 15056 DUCTILE-IRON PIPE AND FITTINGS
SECTION 15056 PART 1 GENERAL 1.01 DESCRIPTION This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems. A written request to use Ductile
SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
DIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
Mechanical Joint Restraints
-15 PVC Pipe Restrainer The PVC mechanical joint restrainer eliminates the need for thrust blocking, tie rodding, or harnessing mechanical joint fittings when they are used with PVC pipe. The key to the
505.3.6 For a building with a crawl space, see Figure 10. 505-1
505 WATER SERVICE INSTALLATION 505.1 DEFINITION A service line is comprised of the piping and related appurtenances including the connection installed from the Des Moines Water Works water main to the
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.
Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.
PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,
Standard Specifications for Installation and Repairs of Water and Sewer Service Lines
Standard Specifications for Installation and Repairs of Water and Sewer Service Lines Effective December 1, 2013 Approved /S/ Kyle Mathis Kyle Mathis City Engineer /S/ Robert Glenn Robert Glenn Water/Wastewater
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe 1. GENERAL The following supplemental sewer main specifications are intended to address the installation of high-density polyethylene
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
American- Darling 5¼" B-84-B-5.
-5 Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which
STANDARD SPECIFICATION SECTION 15292 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900)
STANDARD SPECIFICATION SECTION 15292 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900) PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of PVC pressure pipe
SECTION 15 AIR RELEASE VALVE ASSEMBLIES. 15-1 General
SECTION 15 AIR RELEASE VALVE ASSEMBLIES 15-1.01 Scope 15-1 General This section describes the requirements for furnishing and installing Air Release Valve Assemblies of the size and type shown on the plans,
SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
SECTION 200: STORM SEWER CONSTRUCTION STANDARDS
SECTION 200: STORM SEWER CONSTRUCTION STANDARDS Page No. Description 200-2 201 GENERAL 200-2 201.1 SPECIFICATIONS 200-2 201.2 CONNECTION TO EXISTING FACILITIES 200-3 202 MATERIALS 200-3 202.1 PIPES 200-4
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
4 of 303 10/7/2014 12:51 PM
National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 4 of 303 10/7/2014 12:51 PM Second Revision No. 167-NFPA 13-2014 [ Section No. 3.8.1.3
Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes
ARMTEC.COM Drainage Solutions and Water Treatment / HDPE DRAINAGE TUBING (BIG O) PRODUCT GUIDE Single-wall corrugated drainage tubing is ideal for agricultural and residential applications Durable Economical
Special Specification 7021 Water Main and Sewer Line Replacements
Special Specification 7021 Water Main and Sewer Line Replacements 1. DESCRIPTION Furnish, install, or replace water pipe, water valves, water meters and boxes, water service connections, fire hydrant assemblies,
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
Pipe Repair Products A complete selection for all types of pipe
Pipe Repair Products A complete selection for all types of pipe Mueller Service Saddles Manufactured and tested in accordance with ANSI/AWWA C800 & NSF 61 certified. Mueller service saddles, available
CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS
CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection
PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE
REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE Storm Sewer Design Criteria REVISED July 2009 PUBLIC WORKS STORM SEWER DESIGN CRITERIA TABLE OF CONTENTS 1.0
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
The Manitoba Water Services Board SECTION 027030 Standard Construction Specifications September 2013 Page 1 of 21
September 2013 Page 1 of 21 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of sewers including: the supply and installation of pipe, saddles, tees,
General Guidelines for Repairing Buried PE Potable Water Pressure Pipes
515 General Guidelines for Repairing Buried PE Potable Water Pressure Pipes Introduction Traditional piping systems have gasket-sealed bell and spigot joints every 20 feet, which can be a potential maintenance
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.
SECTION 3000 - SANITARY SEWERS 3001 SCOPE. This section applies to sanitary sewer construction and shall consist of furnishing all labor, materials, and equipment for the complete installation of sewers
SECTION 15064 PVC PRESSURE PIPE AWWA C900
SECTION 15064 PVC PRESSURE PIPE (AWWA C900) PART 1 GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of polyvinyl chloride (PVC) pressure pipe conforming to AWWA C900.
MOBILE AREA WATER AND SEWER SYSTEM. Section 12. Sanitary Sewer Standard Specifications
MOBILE AREA WATER AND SEWER SYSTEM Section 12 Sanitary Sewer Standard Specifications May 31, 2012 TABLE OF CONTENTS 12.01 SCOPE:... 5 12.02 WORK INCLUDED:... 5 12.03 PIPELINE SYSTEM MATERIALS:... 5 A.
Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
Fabricated Drainage Products
Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
September 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification 020.01 GRAVITY SANITARY SEWER SYSTEM
1.0 General Technical Specification 020.01 GRAVITY SANITARY SEWER SYSTEM a) It is the intent of this specification to ensure that all gravity sewer system infrastructure constructed within the service
WATER & SEWER CORROSIVE RESISTANT PRODUCTS
WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
Ductile Iron Pipe Couplings
J-9 Pipe 1 2 Straight and Transition Ductile offer an easy and economical way of joining whether the is of the same nominal and/or type or different at each coupling. couplings will handle most of your
LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM
North American Society for Trenchless Technology (NASTT) No-Dig Show 2010 Chicago, Illinois May 2-7, 2010 Paper D-4-02 LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
MATERIAL SPECIFICATION MANUAL
MATERIAL SPECIFICATION MANUAL Created Date: 01/25/05 (JJS) Last Revised Date: 11/29/10 (JJS) When working with Pinellas County (EES), suppliers and contractors shall actively follow EES's published material
Royal Seal Gasketed Sewer Pipe
Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof
CW 2130 - GRAVITY SEWERS TABLE OF CONTENTS
August 2010 CW 2130 - GRAVITY SEWERS TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications... 1 1.4 Referenced Standard Details...
Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
Ford Service Saddles and Tapping Sleeves
THE FORD METER BOX COMPANY, INC. ISO 9001:2008 10002505 Section AA 02/2015 Web Revision 12/17/2015 Ford Service Saddles and Tapping Sleeves Contents Page Recommended Product Application *Steel *C900 Cast
City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014
City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014 Section Subsection Name Date Modification Division 1 All subsections General Provisions
Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE
1.0 GENERAL 1.1 DESCRIPTION This section addresses the procedures to be employed for pipe bursting existing water/sewer pipelines, as identified on the drawings, and replacing with new Restrained Joint
LS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
TECHNICAL SPECIFICATION
THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,
Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description
Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard
The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe
The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,
32-02.05 Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.
SECTION 32: SANITARY SEWER INSTALLATION 32-01 SCOPE. The Work shall consist of furnishing and installing sewer mains, manholes, laterals, cleanout fittings and appurtenances; and testing, flushing and
REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS
GENERAL REQUIREMENTS METER, METER VAULT, AND SERVICE LINE REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED METER, METER VAULT, AND SERVICE LINE REQUIREMENTS METER & METER VAULT: 1. METER AND RADIOREAD
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
SECTION G SEWERS (STORM, SANITARY AND FDC)
G-1 GENERAL SECTION G SEWERS (STORM, SANITARY AND FDC) The Consulting Engineer is to monitor all specified pipe and granular materials, pipe slopes and run lengths and ensure the outlined criteria below
SECTION 6A STORM DRAIN DESIGN Mar. 2002 S E C T I O N 6A STORM DRAIN - DESIGN
S E C T I O N 6A STORM DRAIN - DESIGN 6A.l Scope 6A.2 Storm Water Quantity 6A.3 Storm Drain Hydraulics 6A.4 Depths 6A.5 Locations 6A.6 Curved Storm Drains 6A.7 Manholes 6A.8 Catch basins 6A.9 Storm Drain
SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2016
SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2016 102.5 Bid Deposits The City of Madison bid deposit form is required for all bids unless a Biennial Bid Bond is on file or check deposit is used.
ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS. for (PVC) SANITARY SEWER MAIN CONSTRUCTION
ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS for (PVC) SANITARY SEWER MAIN CONSTRUCTION VI(A).1 General VI(A).2 Materials and Equipment VI(A).3 Installation of Sanitary Sewer Mains VI(A).4 Laying of
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)
CHAPTER 9 SEWER / STORM DRAIN / IRRIGATION LINES SECTION 9.01 GENERAL This section covers the requirements for piping materials and installation of Lehi City sewer, storm drainage and irrigation collection
SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS
SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the General and Supplementary Conditions and Division 1 Specification
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination