DCMax. Cabinets. feature of Cabinets
|
|
|
- Candace Bryant
- 10 years ago
- Views:
Transcription
1 Cabinets As we have seen in previous pages, cooling and power management is very important in Data Center projects. But you need to build a good house for your active and passive equipments. feature of Cabinets IP20 protection level for cooling performance. %80 perforated front/rear doors for best air circulation. Easy move 19 rails while loaded. Curved door for free space for front cabling. Heavy duty structure, 1500kg load carrying capacity. Wide Range of cabinet sizes and accessories. Dimensions: 42/47U 600 or 800x1000/1100/1200 mm Ready for cold / hot corridor containment. Ample variety of accessories. Maximum inner space for servers. Professional cable management on top, bottom and inner of cabinet. Compatibility with all vendors servers. High technical performance; grounding continuity. Aesthetic and professional view. Overhead cable trays separate electrical and data cables. 2 and 4 section Co-Location cabinets. By using cable rings, airflow is improved, installation time and cost is reduced. It creates space savings and flexibility inside the cabinet. Passed Belcore Zone 4 earthquake test with 1000kg. load. With special design of side frames, you can move the 19 mounting rails while equipments loaded. Simply the raceway for cables are created by fixing cable rings on all profiles in front and rear part of the cabinets. Cabinet is one of the important structure of housing. To fix your equipments and to manage the cabling well organized, Estap provides a wide variety of cabinets and accessories. 1
2 main structure Closed Form Frame Structure: Produced from DKP sheetmetal with a special technique to have a strong frame. rear roof Structure: Produced from DKP sheet metal. The flat door has %80 perforations to have a good air flow. Can open 130 Locking Mechanism: 3 point lock, handle with semi cylindirical barrel of EMKA. Hinge System: 3 pcs Zinc alloy Steel to fix the door. roof FRONT DOOR Structure: Produced from DKP sheet metal. The curved door has %80 perforations to have a good air flow. Provides enough space for patch cords between door and equipment. Can open 130. Locking Mechanism: 3 point lock, handle with semi cylindirical barrel of EMKA. Hinge System: 3 pcs Zinc alloy Steel to fix the door. SIDE PANEL Structure: Produced from DKP sheet metal. Thickness is 1,5mm. Fixed to cabinet from 8 point by screw. 2 pcs in one side. Structure: Produced from DKP sheet metal. Suitable to fan fixing. Cable Entry Alternatives High cable entry possibility. Brush type cable entries. Sliding cover cable entries. Cable Manager Bag option. Environment: EN /4.2, IEC , IEC , IEC , IEC60917 ve IEC60297 Industrial Enviroment: EN /4.3, IEC , IEC and IEC , IEC , IEC60917 ve IEC60297 Static Mechanical Loding Test: EN / 5.2.1, IEC60917 and IEC60297 Static Mechanical Structure: EN / 5.2.2, IEC60917 ve IEC60297 Dynamic Load, Vibration and Mechanic: EN / 5.3.1, EN / 5.3.3, IEC60917, IEC60297, IEC62208 Earthing: EN / 6.2, IEC60917 ve IEC60297 Fire Resistance: EN / 6.3, IEC60917 and IEC60297 Corossion: ISO9227 and ASTM B , IEC60917 and IEC60297 IP Protection Level: IP20 regarding to EN / 6.4, IEC60529, IEC60917 and IEC60297 Carrying: ETS Class2.3 Loading: ETS Class1.2 Security: EN60950_LVD Loading Capacity: 1500 kg static load. Passed earthquake test with 1000kg. (BELLCORE GR-63-CORE ZONE 4, NEBS requirements). Purchased Product Certificates: Sheet Metal: ISO 9001, DIN EN Ereğli DC , RoHS Electrostatic Dry Paint: ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO , ISO , RoHS, Reach, ISO , ISO 8130, ISO 1519, ISO 1520, ISO 2815, ISO 2409 Fan: ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass: ISO 9001, EN : 2000 (tempered/security glass) Fixing units (screw, washer, nut, etc): DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors: ISO 9001, TS EN 12530, TS EN 12532, RoHS Locking Systems: DIN 1743, DIN 53571, RoHS 2
3 seismic test report Bellcore Seismic Test shows us, the cabinet is how durable against vibration and movement. load carrying capacity test 1500kg Static Load to fix your equipments without any hesitation. BELLCORE GR-63-CORE zone 4 (NEBS requirements) TEST HAS BEEN PASSED WITH 1000kg! Diagonal Dimensions of ESTAP DCMAX Data Center Cabinet at Each Static Load resonance frequency search Date Axis Program Duration Graph No Comments 21/01/10 Z A 6 min. 1 to 14 Nothing to report 21/01/10 X A 6 min. 15 to 28 Nothing to report 21/01/10 Y A 6 min. 29 to 42 Nothing to report earthquake resistance test Date Axis Program Duration Graph No Comments 22/01/10 Z B 30 s A 43 to 68 22/01/10 X B 30 s B 69 to 94 Nothing to report. No damage was observed on each tested part. Nothing to report. No damage was observed on each tested part. Dimensions Static Load (kg) Dimensions Thanks to the special structure and design, Estap DcMax cabinets can carry 1500kg static load. 22/01/10 Y B 30 s C 95 to 120 Remark: during test, opening of the front mesh door and the rear mesh door. See video. Deformation of the front mesh door of the cabinet. Deformation of the rear mesh door closing linage. It is noted deformations inside the cabinet on recoveries of the 4 pillars. ESTAP informed SOPEMEA that door are not a relevant tested part (only for integration of cabinet for test process) Cracks on 2nd and 3rd rack. Deformation of vertical pillar on the 1st and 2nd rack. It s not broken, no cracks are detected. No deformation on the outer structure of the cabinet (out of mesh doors). 3
4 top views Bellcore Seismic Test shows us, the cabinet is how durable against vibration and movement. roof options Possibility to fit Manager Bag Possibility to fit Fan Tray Cable entries 4
5 Cabinet Dimensions and Part No - W600 Single Opening, Curved, %80 Perforated Front Door; Double Opening, %80 Perforated Rear Door. PART NO DESCRIPTION DIMENSIONS W x H x D SRVES42U61055PWPD SRVES42U61155PWPD SRVES42U61255PWPD SRVES47U61055PWPD SRVES47U61155PWPD SRVES47U61255PWPD 19 42U, 600x1000 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors 19 42U, 600x1100 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors 19 42U, 600x1200 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors 19 47U, 600x1000 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors 19 47U, 600x1100 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors U, 600x1200 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors 600x2000x x2000x x2000x x2200x x2200x x2200x1200 5
6 Cabinet Dimensions and Part No - W600 Single Opening, Curved, %80 Perforated Front Door; Double Opening, %80 Perforated Rear Door. PART NO DESCRIPTION DIMENSIONS W x H x D SRVES42U61055PWP SRVES42U61155PWP SRVES42U61255PWP SRVES47U61055PWP SRVES47U61155PWP SRVES47U61255PWP 19 42U, 600x1000 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 600x1100 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 600x1200 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 600x1000 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 600x1100 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 600x1200 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors. 600x2000x x2000x x2000x x2200x x2200x x2200x1200 6
7 Cabinet Dimensions and Part No - W800 Single Opening, Curved, %80 Perforated Front Door; Double Opening, %80 Perforated Rear Door. PART NO DESCRIPTION DIMENSIONS W x H x D SRVES42U81055PWPD SRVES42U81155PWPD SRVES42U81255PWPD SRVES47U81055PWPD SRVES47U81155PWPD SRVES47U81255PWPD 19 42U, 800x1000 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors U, 800x1100 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors U, 800x1200 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors U, 800x1000 mm DcMAX, %80 Perforated, Single Opening Fron and Double Opening Rear Doors U, 800x1100 mm DcMAX, %80 Perforated, Single Opening Front and Double Opening Rear Doors U, 800x1200 mm DcMAX, %80 Perforated, Single Opening Fron and Double Opening Rear Doors. 800x2000x x2000x x2000x x2200x x2200x x2200x1200 7
8 Cabinet Dimensions and Part No - W800 Single Opening, Curved, %80 Perforated Front Door; Double Opening, %80 Perforated Rear Door. PART NO DESCRIPTION DIMENSIONS W x H x D SRVES42U81055PWP SRVES42U81155PWP SRVES42U81255PWP SRVES47U81055PWP SRVES47U81155PWP SRVES47U81255PWP 19 42U, 800x1000 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 800x1100 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 800x1200 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 800x1000 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 800x1100 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors U, 800x1200 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors. 800x2000x x2000x x2000x x2200x x2200x x2200x1200 8
9 Cabinet Dimensions and Part No - W300 W=300 mm cabinets are designed for Estap side cooling units. PART NO DESCRIPTION DIMENSIONS W x H x D SRVES42U31055PWP SRVES42U31155PWP SRVES42U31255PWP SRVES47U31055PWP SRVES47U31155PWP SRVES47U31255PWP 19 42U, 300x1000 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors; Housing For Side Cooler 19 42U, 300x1100 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors; Housing For Side Cooler 19 42U, 300x1200 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors; Housing For Side Cooler 19 47U, 300x1000 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors; Housing For Side Cooler 19 47U, 300x1100 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors; Housing For Side Cooler 19 47U, 300x1200 mm DcMAX, %80 Perforated, Single Opening Front and Rear Doors; Housing For Side Cooler 300x2000x x2000x x2000x x2200x x2200x x2200x1200 9
10 DCMax high density cabling cabinet Professional cabinet solution for professional cabling. Exploded View Iso View H h 9,5 44,5 19'' Front View Inside View Side View Back View Top View ,7 120 Bottom View 10
11 PART NO DESCRIPTION W x H x D SRVES42U8855OFRM SRVES42U8855SCCIP20 SRVES42U81055SCCIP20 SRVES42U81155SCCIP20 SRVES42U81255SCCIP20 SRVES47U8855OFR SRVES47U8855SCCIP20 SRVES47U81055SCCIP20 SRVES47U81155SCCIP20 SRVES47U81255SCCIP U 800x800 mm DCMAX Cabling Open Frame Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front. Cabinet is without side panels, front and rear door U 800x800 mm DCMAX Cabling Open Frame Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front. Cabinet is without side panels, front and rear door U 800x1000 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door U 800x1100 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door U 800x1200 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door U 800x800 mm DCMAX Cabling Open Frame Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front. Cabinet is without side panels, %80 perforated front and rear door U 800x800 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door U 800x1000 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door U 800x1100 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door U 800x1200 mm DCMAX IP20 Cabling Closed Cabinet, including 4ea. 19 mounting profile. 4ea. Vertical cable management panel at left and right, rear and front, complete with side panels, %80 perforated front door and rear door. 800x2000x x2000x x2000x x2000x x2000x x2200x x2200x x2200x x2200x x2200x
12 DCMax co-location cabinets Sometimes your equipments not fill much more than 10U or 20U. In this case you need Co-Location cabinets. PART NO SRVES47U61055PWPC2 SRVES47U61055PWPC4 SRVES47U61155PWPC2 SRVES47U61155PWPC4 SRVES47U61255PWPC2 SRVES47U61255PWPC4 DESCRIPTION DIMENSIONS WxHxD 47U 600X1000 mm, DCMAX IP20 %80 Perforated single opening front and rear doors, mechanical lock, black, co-location, 2 compartment 600x2200x U 600X1000 mm, DCMAX IP20 %80 Perforated single opening front and rear doors, mechanical lock, black, co-location, 4 compartment 600x2200x U 600X1100 mm, DCMAX IP20 %80 Perforated single opening front and rear doors, mechanical lock, black, co-location, 2 compartment 600x2200x U 600X1100 mm, DCMAX IP20 %80 Perforated single opening front and rear doors, mechanical lock, black, co-location, 4 compartment 600x2200x U 600X1200 mm, DCMAX IP20 %80 Perforated single opening front and rear doors, mechanical lock, black, co-location, 2 compartment 600x2200x U 600X1200 mm, DCMAX IP20 %80 Perforated single opening front and rear doors, mechanical lock, black, co-location, 4 compartment 600x2200x
13 DCMax system rack-open frame Sometimes you need simple solutions for patching cabinets. System Rack has high capability of cabling and easy access from all sides. PART NO DESCRIPTION DIMENSIONS WxHxD LR26U 80 26U 19'' Systemrack, D=80 530x1290x80 LR36U 80 36U 19'' Systemrack, D=80 530x1734x80 LR42U 80 42U 19'' Systemrack, D=80 530x2001x80 LR48U 80 48U 19'' Systemrack, D=80 530x2134x80 LR42U U 19'' Systemrack, D= x2001x160 LR48U U 19'' Systemrack, D= x2134x160 LR42U U 19'' Systemrack, D= x2001x420 LR48U U 19'' Systemrack, D= x2134x420 Vertical Cable Manager Options PART NO DESCRIPTION DIMENSIONS WxHxD M44ORG2613RLYG 26U Vertical cable management panel 1ea. w=135mm, Finger Type 135x1292x250 (1176) M44ORG3613RLYG 36U Vertical cable management panel 1ea. w=135mm. Finger Type 135x1736x250 (1620) M44ORG4213RLYG 42U Vertical cable management panel 1ea. w=135mm, Finger Type 135x2003x250 (1887) 48U Vertical cable M44 ORG4813RLYG management panel 1ea. w=135mm, Finger Type 135x2270x250 (2154) M44ORG2626RLYG 26U Vertical cable management panel 1ea. w=260mm, Finger Type 260x1292x250 (1176) M44ORG3626RLYG 36U Vertical cable management panel 1ea. w=260mm, Finger Type 260x1736x250 (1620) M44ORG4226RLYG 42U Vertical cable management panel 1ea. w=260mm, Finger Type 260x2003x250 (1887) M44ORG4826RLYG 48U Vertical cable management panel 1ea. w=260mm, Finger Type 260x2270x250 (2154) 13
14 accessories / bottom cover To close the bottom of the cabinet for dust protection. PART NO DESCRIPTION W x D EST30110BTCVR EST30120BTCVR EST60100BTCVR EST60110BTCVR EST60120BTCVR EST80100BTCVR EST80110BTCVR EST80120BTCVR Bottom Cover - c/w Multiple Cable Entry Plates width=300 mm depth=1100 mm Bottom Cover - c/w Multiple Cable Entry Plates width=300 mm depth=1200 mm Bottom Cover - c/w Multiple Cable Entry Plates width=600 mm depth=1000 mm Bottom Cover - c/w Multiple Cable Entry Plates width=600 mm depth=1100 mm Bottom Cover - c/w Multiple Cable Entry Plates width=600 mm depth=1200 mm Bottom Cover - c/w Multiple Cable Entry Plates width=800 mm depth=1000 mm Bottom Cover - c/w Multiple Cable Entry Plates width=800 mm depth=1100 mm Bottom Cover - c/w Multiple Cable Entry Plates width=800 mm depth=1200 mm 300x x x x x x x x
15 accessories / plinth To raise the cabinet where you need PART NO DESCRIPTION W x D EST PLNTH Plinth for DCMAX width=300 mm depth=1000 mm 300x1000 EST PLNTH Plinth for DCMAX width=300 mm depth=1100 mm 300x1100 EST PLNTH Plinth for DCMAX width=300 mm depth=1200 mm 300x1200 EST PLNTH Plinth for DCMAX width=600 mm depth=1000 mm 600x1000 EST PLNTH Plinth for DCMAX width=600 mm depth=1100 mm 600x1100 EST PLNTH Plinth for DCMAX width=600 mm depth=1200 mm 600x1200 EST PLNTH Plinth for DCMAX width=800 mm depth=1000 mm 800x1000 EST PLNTH Plinth for DCMAX width=800 mm depth=1100 mm 800x1100 EST PLNTH Plinth for bw width=800 mm depth=1200 mm 800x
16 accessories / floor fixing kit and castor set To fix the cabinet to floor for more stability accessories / cable management rings To guide your cables where you need. PART NO DESCRIPTION PART NO DESCRIPTION W x H M44FFK Floor fixing kit (1set=4pcs.) from inner corner of cabinet K44 RING 06 Ring for cable management 45x100 mm (1 set = 5 ea.) 45x100 M44FFK TKR Castor Group (1set=4pcs.) K44 RING 05 Ring for cable management 60x100 mm (1 set = 5 ea.) 60x Cable Rings can be used in all cable trays, vertical and horizantal C rails, framework of cabinet itself. 16
17 accessories / vertical cable manager To guide and manage the cabling cables vertically. PART NO DESCRIPTION W x H x D accessories / blank panels Airflow management is an important factor for a successful Data Center operation and contributes much to the availability. To have a perfect airflow inside the cabinet, vertical and horizontal blank panels should be used. M78 ORG42 M78 ORG47 BZTRB IP20 42U Vertical Cable Manager, Finger type with metal cover. 47U Vertical Cable Manager, Finger type with metal cover. Cable Manager Bag 92x1885x179 92x2110x x200x200 19'' Cable Manager Bag Fix and tighthened the bag to prevent air leakage from cable entry Without blank panel Vertical Cable Manager, Finger Type H With blank panel Air flow with or without blank panels inside cabinet 17
18 accessories / blank panels Close unused units in the rack with blanking panels to avoid airflow short circuit inside the rack. PART NO DESCRIPTION W x H x D E44BPN01 E44BPN02 E44BPN03 E44BPN04 E44BPN05 E44BPN06 E44BPN01 E44BPN02 E44BPN01_03 E44BPN01_TMP E44BPN4288 E44BPN4788 E44BPN4266 E44BPN4766 E44BPN4288_AFM E44BPN4788_AFM 1U 19 Blank panel 2U 19 Blank panel 3U 19 Blank panel 4U 19 Blank panel 5U 19 Blank panel 6U 19 Blank panel 1U 19 Blank panel vented 2U 19 Blank panel vented 1U 19 Toolless Blank panel 1U 19 Toolless Blank Panel, With Temperature trip 42U Vertical blank panel for w=800 mm cabinets (1set=2pcs. Left + right) 47U Vertical blank panel for w=800 mm cabinets, (1set=2pcs. Left+right) 42U Vertical blank panel for w=600 mm cabinets, brush (1set=2pcs. Left+right) 47U Vertical blank panel for w=600 mm cabinets, brush (1set=2pcs. Left+right) 42U Vertical blank panel with cable entries for w=800 mm cabinets (1set=2pcs. Left + right) 47U Vertical blank panel with cable entries for w=800 mm Cabinets (1set=2pcs. Left + right) 483x12x44 483x12x88 483x12x x12x x12x x12x x12x44 483x12x88 483x12x44 483x12x44 100x1900x63 100x2125x63 80x1934x3 80x2150x3 100x1900x63 100x2125x63 18
19 accessories / cable management on cabinet top Estap DcMax Server Cabinets offer professional and highly secured management of high density data and power cables. Separate cable inlet for data and energy cables, and separate overhead cable trays and dividers minimize the electromagnetic and physical interference. PART NO DESCRIPTION W x H M44CS1230 Cable separator on Cabinet Roof h=120 mm w=300 mm (each) 300x120 M44CS1260 Cable separator on Cabinet Roof h=120 mm w=600 mm (each) 600x120 M44CS1280 Cable separator on Cabinet Roof h=120 mm w=800 mm (each) 800x120 M44CT2030 M44CT2060 M44CT2080 Cable Tray on Cabinet Roof h=200 mm w=300 mm (each) (useful dimension for cabling: w=600 mm d=150 mm h=80 mm) Cable Tray on Cabinet Roof h=200 mm w=600 mm(each) (useful dimension for cabling: w=600 mm d=150 mm h=80 mm) Cable Tray on Cabinet Roof h=200 mm w=800 mm (each) (useful dimension for cabling: w=800 mm d=150 mm h=80 mm) 300x x x200 10, ,9 1, ,5 17,5 105 A 105 B 20,3 76,4 20,3 75,6 17,5 17,5 A B (D-1) x Dx nx 6 C 19
20 accessories / baying kit Can bay while the side panels are onto the cabinet. Can bay while there is no side panels. PART NO DESCRIPTION M44BLG05 M44BLG04 Baying kit from inside of Datacenter cabinets (used when side panels are not mounted) 1set=6pcs. Baying kit from outside of Datacenter cabinets (used when side panels are on cabinet) 1set=4pcs. (2ea for bottom, 2ea. for top) 20
21 accessories / cable trays With Estap Cable Tray, you can manage your cables on side of the cabinet. Also you can fix cable manager rings on it. PART NO DESCRIPTION W x H E44 KNL42 CHLD 42U Multipurpose C profile as cable holders, rings and management 10x103x1814 E44 KNL47 CHLD 42U Multipurpose C profile as cable holders, rings and management 10x103x X6,5 32 1,5 12,5 12,
22 accessories / front label plate Also, front Labeling Plate is necessary for a good view and to fit aisle roofs well. PART NO DESCRIPTION W x H M44FLP1230 Front Label Plate h=120 mm w=300 mm 300x120 M44FLP1260 Front Label Plate h=120 mm w=600 mm 600x120 M44FLP1280 Front Label Plate h=120 mm w=800 mm 800x A B 2X 6, ,5 1, ,
23 corridor solutions In data center rooms, to have efficient cooling and to have a well organized system, corridor solutions are the right instrument. A closed corridor can provide roughly %40 cooling efficiency. Estap can provide different closing alternatives, although the racks have different hights or widths. Also suitable for future expansions. aisle roof To close the top of hot/cold aisle. Easy to fix. Polycarbonate closing with reinforced metal frame. PART NO DESCRIPTION W x D M44CCR60120 M44CCR80120 M44CCR90120 M44CCR Cold Coridor Roof w=600 d=1200 mm polycarbonate transparent top cover with metal frame. Cold Coridor Roof w=800 d=1200 mm polycarbonate transparent top cover with metal frame. Cold Coridor Roof w=900 d=1200 mm polycarbonate transparent top cover with metal frame. Cold Coridor Roof w=1100 d=1200 mm polycarbonate transparent top cover with metal frame. 600x x x x1200 Please contact to Sales Department for more alternative solutions. 23
24 corridor DOORS 2 types of door options are available as automatic opening and manuel opening. System is CE, TUV and ISO certificated. Automatic Opening Wing Frame Metarial: Aluminium. Glass: 4+4 mm transparent laminated glass with Estap Logo. Carrier System: 5 x 60 x 120 mm 4x brackets; 40 x 60 x 2mm Alm. Profile posts. Carrier wide: 3200mm 3600 mm* Security Sensor: Active 8 curtain photocell sensor. Mechanism Wide: 2500 mm Corridor Wide: 1200 x 2240 mm Wings: 2 x moving wings, automatic. Locking: Electro-mechanic locking systems. Locking Options: Keypad or Proximity Card.** Colour: RAL 9005 and RAL 7035 corridor DOORS Manuel Opening Wing Frame Metarial: Aluminium. Glass: 4+4 mm transparent laminated glass with Estap Logo. Carrier System: 5 x 60 x 120 mm 4x brackets; 40 x 60 x 2mm Alm. Profile posts. Carrier wide: 3200mm 3600 mm* Mechanism Wide: 2500 mm Corridor Wide: 1200 mm Wings: 2 x synchronized wings. Locking: Lock to the bottom. Colour: RAL 9005 and RAL 7035 *Depends to the cabinets depth. ** Proximity system can be adapt to Estap EMS system. *Depends to the cabinets depth. 24
25 DCMax environmental monitoring systems software features Main Unit EST-EM3000 User Friendly Web-Interface Alarming over , SMS, Voice Calling Module and LCD Display IP address monitoring on the LCD Display Critical and Alarming Level Setup Minimum and Maximum Alarming Value Assignment SNMP Support Easy Setup and Configuration IP Camera Support Which initializes external sensors, requests data from sensors, evaluates and archives the data, generates alarm when necessary and intervenes the output process, is the core of the EST-EM3000 architecture. EST-EM3000 is an IT unit where required applications run on Linux operating system. The Internal components other than the main unit are, 1 Temperature-Humidity Sensor, 4 Analog Inputs or Water Sensor ports, 4 Relay Outputs, 16 Dry Contacts, 2 RS232 COM Ports, 2 USB Ports, 1 LAN port, 1 LCD Screen, 1 Buzzer and 16 ExaBus Ports. To monitor and control the system which has main unit more than 1, centralised monitoring program is needed. hardware features 19 Rack Installation 1 x internal Temperature&Humidty Port 1 x built-in Temperature&Humidty Sensor with extension cable 16 x Sensor Ports 16 x Dry Contact Ports all isolated 1 Ethernet Port 4 x Analog/Water Sensor Ports 4 x 10A Relay Outputs 2 x RS-232 Ports 2 x USB Ports 1 x integrated Buzzer 2 x 12V DC Output (1x12V DC for Redundancy) 25
26 environmental monitoring systems Main Unit EST-EM2000 EST-EM2000 is especially designed for Smart Cabinet solutions to basically monitor the environment. System is same with EST-EM3000, just EST-EM2000 has few connection ports. software features User Friendly Web-Interface Alarming over , SMS, Voice Calling Module and LCD Display IP address monitoring on the LCD Display Critical and Alarming Level Setup Minimum and Maximum Alarming Value Assignment SNMP Support Easy Setup and Configuration hardware features 1 x internal Temperature&Humidty Port 3 x Sensor Ports 4 x Dry Contact Ports all isolated 1 Ethernet Port 1 x Analog/Water Sensor Ports 2 x 10A Relay Outputs sensors EST-EM3010 Temperature Humidity Sensor EST-EM3020 Temperature Sensor EST-EM3030 Water Sensor EST-EM3031 Water Detect Cable 1 m EST-EM3035 Water Detect Cable 5 m EST-EM3040 One Three Phase V/F Sensor EST-EM3050 Airflow Sensor EST-EM3060 Air Quality Sensor EST-EM3070 Vibration Sensor EST-EM3080 Light Detector EST-EM3090 Rack Mount Battery Pack 24 hours Back Up EST-EM3100 Smoke Detector EST-EM3110 Door Detector EST-EM3120 Movement Sensor EST-EM3130 Proximity Reader EST-EM3131 Proximity Card EST-EM3141 Cabinet Door Lock EST-EM3142 Room Entrance Lock EST-EM3151 Signal Tower with Buzzer EST-EM3152 Buzzer EST-EM3160 GSM Module EST-EM3170 3G Router Module EST-EM3180 Voice Calling Module EST-EM3190 Integration Module&Software EST-EM3001 COMBO Sensor 1 x Temperature Humidity Sensor 4 x Dry Contact Ports All Isolated 2 x Relay Output 1 x Proximity Reader Port 1 x Water Detect Cable Port CENTRALISED MANAGEMENT SOFTWARE EST-CMP5 Centralised Management Pack, 1-5 Nodes EST-CMP15 Centralised Management Pack, 1-15 Nodes EST-CMPU Centralised Management Pack, Unlimited Node Licence 26
27 DCMax intelligent power distribution units consoles with kvm switch 20xIEC 320 (16xC13 + 4xC19) Socket MANAGED IP PDU with Ampermeter Display, ZeroU, aluminium profile frame, 2x16A MCB, 8000 Watt, 250V AC, 3x6.0mm2, 3m cord with IEC60309 plug (32A 2P+E), CE mark, daisy-chain function upto 10 units, Remote Monitoring ports for temperature-humidity-door access-water leakage-smoke. Support an optional remote console (Cat5 based or Over-IP) CAT5 console up to 1000 feet away from KVM switch with superior auto-adjust RGB gain/delay control capability Support multiplatform - PS/2 and USB computers (SUN and MAC) Support DOS. Windows, Netware, Unix, MacOS Hot Pluggable-Add or remote connected PCs without having to power down the KVM switch or PCs. Superior video quality-up to 1280x1024, DDC2B No software required-easy PC selection via Push Buttons, Hot Keys or OSD (on screen display) Support Daisy Chainning up to 7 additional units Auto Scan Mode for monitoring PCs Firmware upgradeable for stying compatible with new coming computers Metal case, rack mountable 20xIEC 320 (16xC13 + 4xC19) Socket MONITORED IP PDU with Ampermeter Display, ZeroU, aluminium profile frame, 2x16A MCB, 8000 Watt, 250V AC, 3x6.0mm2, 3m cord with IEC60309 plug (32A 2P+E), CE mark, daisy-chain function upto 10 units, Remote Monitoring ports for temperature-humidity-door access-water leakage-smoke. Outlet monitored and switched PDU, 20xIEC320 C13 socket, 4xIEC320 C19 socket,3x6.0mm2x3.0m cable, Single phase 32A IEC60309 plug, 250v, 32A, with power consumption monitoring. Outlet monitored and switched PDU, 20xIEC320 C13 socket, 4xIEC320 C19 socket, 5x6.0mm2x3.0m cable,three phase 3x32A IEC60309 plug, input 380v, output 230v, 3x32A, with power consumption monitoring. With central management programme Power Sense, you can manage your smart PDUs over one interface. Installation of Console with KWM Switch 27
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
How To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
Compaq Rack Options and Accessories. Monitors and Keyboards
1 Compaq Rack Options and Accessories Compaq offers a wide variety of rack options and accessories that help you to complete your 9000 and 10000 series racks. Monitors and Keyboards TFT5600RKM United States
Rack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
Cabinet V800 V800 CABINETS
V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
06 / 2003. Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide] www.maxdata.de
D Positioning Key-Features Specifications Optional components MAXDATA PLATINUM Server-Rack PLATINUM [Product Guide] www.maxdata.de Positioning Description Server-Racks with 41U, 37U and 23U Highlights
BLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
Customized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks
Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization
Raritan LCD KVM Console (T1700/T1900)
QS Rule Raritan LCD KVM Console (T1700/T1900) Quick Setup Guide Thank you for your purchase of the LCD KVM Console, one of the best-known LCD KVM drawers in the current market. The Raritan LCD KVM Console
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
Secure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1
Knürr DCM 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM conquers the world Standardization in the data center begins with the Knürr DCM! The Knürr DCM is the modular building block
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
Powerware Enclosure Solutions Product Focus
Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is
CABINET & ENCLOSURE WWW.LINKBASIC.COM STANDARD FEATURES MATERIALS APPLICATION N C B C A B I N E T P/N:NCB
STANDARD Comply with ANSI/EIARS-30-D, DIN9; PART, IEC97-, DIN9; PART7, GB/T307.-9 standard. Compatible with metric ETSI and 9 inch international standard. FEATURES Exquisite design with precise craftsmanship
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
19 NETbox SOHO Network Wall Mounting Cabinets FAMILY
9 NETbox SOHO Network Wall Mounting Cabinets FAMILY DETAILS: Framework- Top/Bottom Cases: Multi Folded Automated Bending technology applied framework and top/bottom cases, provides a heavy duty structure
Networking Cabinets and Enclosures
Networking Cabinets and Enclosures Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise. Networking Cabinets
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION
Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION The heat load in data centers is increasing rapidly, the adaptation of a cooling strategy is often necessary. Many data centers and server rooms use
Dimensions (HxDxW) Total Cabinet Area 89.96x 39.69 x 24 in/ 2,285 x 1,008.17 x 612.77 mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.
1 Compaq 10000 Series Racks The 10000 series racks are a family of 1000mm deep racks which are available in 22U, 36U, 42U and 47U 600mm widths. Compaq 10000 Series Racks provides a common, integrated platform
DCF Optimized Rack System Selection Guide
DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
Data Centre Solutions
Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure
DELTA3-1. Delta 3 Data Centre Rack Solution
DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers
Intelligent Data Center Solutions
Intelligent Data Center Solutions V. 1.1 Tomorrow s Data Centers are Already Here, Cost-effective and Climate Friendly Data centers are a long-term investment for the future. Our quality solutions are
Rack Cabinets. Rack Configuration. 19 inch
Rack Cabinets Rack Configuration 19 inch 19 RACK COMPONENTS FEATURES Hallam Manufacturing s range of 19 inch racks and cabinets for today s data/communications installations are designed and manufactured
THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR
Raritan LCD KVM Console (T1700/T1900)
Raritan LCD KVM Console (T1700/T1900) Quick Installation and Setup Guide Congratulations on your purchase of Raritan LCD KVM Console, one of the best-known LCD KVM drawers in the current market. The Raritan
WORLD. Security Tests. FULL COMPLIANCE From all Quality and SAFE FUNCTIONAL. Delivery from Stock
19 RACK CABINET WORLD STURDY SAFE AESTHETIC FUNCTIONAL FULL COMPLIANCE From all Quality and Security Tests ISO 9001 ISO 14001 DIN/TS/IEC/BS/DS/ EN 61587-1, EN 61587-2 CE ISO 14001:2004 ROSH IEC 297-1/2
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
Cabinets, Racks & Accessories
SOLUTIONS Mulder-Hardenberg B.V., The Netherlands Tel.: +31 (0)23-531 91 84 [email protected] Mulder-Hardenberg N.V., Belgium Tel.: +32 (0)3-660 13 20 [email protected] Mulder-Hardenberg GmbH, Germany Tel.:
KVM-8901. 19 Widescreen LCD KVM Rack Console. User Manual
KVM-8901 19 Widescreen LCD KVM Rack Console User Manual V1.0 TABLE OF CONTENTS 1. Information...- 2-1.1 Overview...- 2-1.2 Features...- 3-1.3 Product Specifications...- 4-2. Panel Control and OSD Function...-
Cisco Nexus 7000 Series.
Data Sheet Cisco Nexus 7000 Series Chassis Product Overview The Cisco Nexus 7000 Series Switches combine the highest levels of scalability with operational flexibility. The Cisco Nexus 7000 Series Switches
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
RACK ENCLOSURES & ACCESSORIES
RACK ENCLOSURES & ACCESSORIES RACK ENCLOSURES NetshelterTM 1 NetShelter VX / NetShelter VS 2 Open Frame Racks 3 NetShelter ES 4 NetShelter WX Part Number Model Height Width Depth Color Application Doors
Colour Video Monitors PVM-9045QM/9042QM/9040ME PVM-6041QM
Colour Video Monitors PVM-9045QM/9042QM/9040ME Specifications GENERAL 9045QM 9042QM Colour system PAL/SECAM/NTSC/NTSC4.43 The CRT type 22 cm (9-inch) HR Trinitron Tube, pursuit 22 cm of (9-inch) excellence
PE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
Rack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
Cabcon. Data Centre Solutions. www.cabcon.co.uk. an acal group company UK +44 (0)1189 122980 IRE (00353) 1 629 2640
Data Centre Solutions www.cabcon.co.uk UK +44 (0)1189 122980 IRE (00353) 1 629 2640 About Us are a specialist distributor of copper, fibre, power, security, active and cable management products for the
Interface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21
Overview Models HP Server Console Switches 1X8-Port KVM 336044-B21 2X16-Port KVM 336045-B21 CAT5e Cables 3 Foot (1 m) 4 pack 263474-B21 6 Foot (2 m) 8 pack 263474-B22 12 Foot (4 m) 8 pack 263474-B23 20
securityprobe 5E Standard
securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke,
RiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
IPSIP M series-m Modular Data Center
IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing
Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems
Miracel 19 rack platform for data center, telecommunication and network technology Rack & Integrated Enclosure Systems The Miracel innovation rack multi-talented, distinguished, integrative The Miracel
8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010. Quick Installation Guide
8/16-Port IP KVM Switch IKVM-8010 / IKVM-16010 Quick Installation Guide Table Of Contents Chapter 1 Introduction... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Technical Specifications... 4 Chapter
Tyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
SMART Board interactive flat panel with appliance Model 8055ie-SMP
Specifications SMART Board interactive flat panel with appliance Model 8055ie-SMP Physical specifications Size 52 3/8" W 32 5/16" H 3 11/16" D (133 cm 82 cm 9.3 cm) (See Physical dimensions on page 7 for
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19
3NNet USERS MANUAL KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19 RACK MOUNTABLE 4 / 8 / 16 PORT PS2 KVM SWITCH Rev 1.1 TABLE OF CONTENTS INTRODUCTION.. 3 FEATURES... 3 PACKAGE CONTENTS........
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Portable Energy Efficient Data Centre Solution
Portable Energy Efficient Data Centre Solution Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354 6447 www.workspace-technology.com
Data Centre solutions Enhanced Data Centre infrastructure
Standard Data rack Centre system solutions (SRS) Capabilities Brochure Model DCS14/001 Data Centre solutions Enhanced Data Centre infrastructure Eaton and Cooper united. Energizing a world that demands
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
DATA CENTER SOLUTIONS
DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
How To Fit A Dll 2420 And 4220 Rack Enclosure
DELL BEST PRACTICES GUIDE FOR RACK ENCLOSURES A Dell Technical White Paper PE2420 & PE4220 By Danny Alvarado Dell Data Center Infrastructure THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY
JAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.
Three simple words that clearly describe how we approach a Data Center project. Eclipse Racks & Enclosures DELIVERING THE RIGHT INFRASTRUCTURE FOR YOUR MISSION-CRITICAL NEEDS SERVER RACKS & NETWORKING
QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview
Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists
Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.
Sensor Control... Control... Sensor Control... Access securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders,
Containment Solutions
Containment Solutions Improve cooling efficiency Separate hot and cold air streams Configured to meet density requirements Suitable for commercial and SCEC endorsed cabinets Available for retrofit to SRA
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
CB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
Rack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
SCD Server. SCD Server Pro
SCD Server SCD Server Pro SCD Server & SCD Server Pro 9850-000387-01 - Page 1 of 8 SCD Server and SCD Server Pro The SCD Server is a 2U high DMX generator, running the ZerOS Operating System and emulating
QuickSpecs. HP IP Console Switch with Virtual Media Overview
Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various
INFRASTRUCTURE FOR DATACENTERS
INFRASTRUCTURE FOR DATACENTERS 02 ENERGY EFFICIENCY IN DATACENTERS The energy efficiency is one of the biggest challenges that datacenter infrastructures are facing today. The datacenters need to have
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER
DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER EXECUTIVE SUMMARY Data center racks were once viewed as simple platforms in which to neatly stack equipment.
MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION
MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static
XIGHTOR DOOR ENTRY SYSTEM. Company Name company address line 1 company address line 2 www.schneider-electric.com
DOOR ENTRY SYSTEM SE002-0115-00 Schneider Electric - All rights reserved Company Name company address line 1 company address line 2 www.schneider-electric.com As standards, specifications and designs change
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
Co-location service from Bell. Version 1.0 April 10, 2007. Updated as of 4/10/2007 1
Co-location service from Bell Version 1.0 April 10, 2007 Updated as of 4/10/2007 1 Contents 1. Introduction... 3 2. Service features... 3 3. Installation guidelines... 4 3a. Equipment installation in racks...
Rack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
Remote Monitoring Unit SC8100. Monitoring Unit SC8100
Monitoring Unit SC8100 Remote Monitoring Unit SC8100 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
CAT5 KVM Extender User Manual
User Manual V2.1 2007.7.3 C o n t e n t s 1. Introduction... 3 1.1 Product Line... 4 1.2 Main Features... 5 1.3 Package contents... 6 1.4 Cables Diagrams... 6 1.4.1 3-in-1 DB15 Cable...6 1.4.2 3-in-1 CAT5