5. The applicable test instruments are selected and testing carried out according to specific task requirements. ASSESSMENT CRITERION NOTES

Size: px
Start display at page:

Download "5. The applicable test instruments are selected and testing carried out according to specific task requirements. ASSESSMENT CRITERION NOTES"

Transcription

1

2

3

4 STAATSKOERANT, 19 DESEMBER 2003 No ASSESSMENT CWITERlON I 1, Conditions are assessed and safety measures implemented according to safe work procedures. ASSESSMENT CRjTERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 2 2. Ensure that the affected section of the Medium / High Voltage network is isolated and permits obtained where necessary when working close proximity to live apparatus according to high voltage regulations. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 3 3. The underground earth connections are exposed and cleaned as per job procedures. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENTCRITERION 4 4. Earth connections are bridged by means a of flexible earth lead prior to disconnecting as per safe work procedures. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 5 5. The applicable test instruments are selected and testing carried out according to specific task requirements. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENTCRITERION 6 6. Safety precautions / procedures are followed before, during and after testing of earthing installation. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 7 7. Safety precautions / procedures are followed before, during and after inspection of earthing installation. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE 03/10/29 US ID: SAM: NLRD Report Unit Standard Detail Page 4

5

6

7

8 STAATSKOERANT, 19 DESEMBER 2003 No SOUTH AFRICAN QUALIFICATIONS AUTHORITY SAQA US ID FIELD DESCRlPTlON UNIT STANDARD: 35 Install / replace high voltage equipment and hardware UNIT STANDARD TITLE Install / replace high voltage equipment and hardware SG8 NAME * SGB Electrical Engineering & Construction ABET BAND Undefined PROVIDER NAME SUBFIELD DESCRiPTlON Electrical Infrastructure Construction ' - Physical Planning and Construction UNIT STANDARD CODE IUNtT STANDARD TYPE INQF LEVEL ICREDITS L I I PPC-EIC-0-SGB ECC llevel4 IRegular (6 REGISTRATION I REGISTRATION END I REGISTRATION I SAQA DECISION NUMBER START DATE I DA TE I NUMBER I PURPOSE OF THE UNIT STANDARD This unit standard is for persons in the electrical distribution station environment. The person credited with this unit standard is capable of planning, installing & replacing, High Voltage equipment (current I voltage transformers, isolators, breakers, surge arrestors) according to statutory requirements to distribute and control electricity to electrical installations. This unit standard will contribute to the full development of the learner within the electrical engineering and construction environment by providing recognition, further mobility and transportability within the field of Physical Planning and Construction. The skills, knowledge and understanding demonstrated within this Unit standard are essential for social and economic transformation and upliftment within the electrical engineering and construction environment. LEARNING ASSUMED ro BE IN PLACE > Apply & maintain safety in an electrical environment (L2 Unit Standard). > Basic hand tools. > Portable power tools. > Introduction to industry. z Plan, install & terminate electrical cables & conductors. > Basic rigging skills. > Operating of Mobile crane. z Read and relate to drawings, circuits & diagrams. > Operating regulations for High Voltage systems - responsible person. UNIT STANDARD RANGE High Voltage equipment include, but are not limited to: > Structure mounted types > Above 33kV, up to and including 132kV High Voltage cables / conductor terminations include, but are not limited to: > Disconnecting & re-connecting cable glands / terminations > Disconnecting 8, reconnecting of droppers I jumpers > Disconnecting & re-connecting earth straps 03/10/29 US ID: SAW: NLRD "Unit Report Standard Detail" Page 1

9

10

11

12

13

14

15

16

17

18

19 SSESS

20

21

22

SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD:

SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD: SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD: Conduct workplace Occupational Health and Safety (OHS) inspections SAQA US ID UNIT STANDARD TITLE 259619 Conduct workplace Occupational

More information

SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD:

SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED UNIT STANDARD: All qualifications and unit standards registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal

More information

0145 or faxed to 012-431 -5144 [email protected]

0145 or faxed to 012-431 -5144 ebrown.@saqa.co.za No. 275 1 April 2005 SOUTH AFRICAN QUALIFICATIONS AUTHORITY (SAQA) In accordance with regulation 24(c) of the National Standards Bodies Regulations of 28 March 1998, the Standards Generating Body (SGB)

More information

National Certificate in Electrical Engineering (Electrician for Registration) (Level 4)

National Certificate in Electrical Engineering (Electrician for Registration) (Level 4) NZQF NQ Ref 1195 Version 3 Page 1 of 11 National Certificate in Electrical Engineering (Electrician for Registration) (Level 4) Level 4 Credits 249 This qualification has been reviewed. The last date to

More information

NZQA registered unit standard 15848 version 6 Page 1 of 5. Demonstrate and apply knowledge of safeguards for use with portable electrical appliances

NZQA registered unit standard 15848 version 6 Page 1 of 5. Demonstrate and apply knowledge of safeguards for use with portable electrical appliances Page 1 of 5 Title Demonstrate and apply knowledge of safeguards for use with portable electrical appliances Level 2 Credits 3 Purpose This unit standard covers knowledge of safeguards used in conjunction

More information

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL S 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 CUSTOMER RESPONSIBILITY FOR TOTAL TEMPORARY SERVICE 4.0 CUSTOMER RESPONSIBILITY FOR TEMPORARY SERVICE IN PERMANENT LOCATION 5.0 NVE RESPONSIBILITIES 6.0 GROUNDING

More information

National Certificate in Electricity Supply (Electrical Services Technician) (Level 4)

National Certificate in Electricity Supply (Electrical Services Technician) (Level 4) NQF Ref 1098 Version 2 Page 1 of 6 National Certificate in Electricity Supply (Electrical Services Technician) (Level 4) Level 4 Credits 109 Purpose This national certificate is awarded to people who have

More information

TROUBLESHOOTING PRELIMINARY

TROUBLESHOOTING PRELIMINARY TROUBLESHOOTING PRELIMINARY To troubleshoot, one must first have a working knowledge of the individual parts and their relation to one another. Must have adequate hand tools Must have basic instrumentation:

More information

OHS Learnership Level 3-79826 SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED QUALIFICATION:

OHS Learnership Level 3-79826 SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED QUALIFICATION: SOUTH AFRICAN QUALIFICATIONS AUTHORITY REGISTERED QUALIFICATION: SAQA QUAL ID National Certificate: Occupational Hygiene and Safety QUALIFICATION TITLE 79806 National Certificate: Occupational Hygiene

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

NQF and the New Zealand Certificate in Electrical Engineering

NQF and the New Zealand Certificate in Electrical Engineering NQF Ref 0223 Version 6 Page 1 of 8 National Certificate in Electrical Engineering (Level 3) Level 3 Credits 149 This qualification has been reviewed. The last date to meet the requirements is 31 December

More information

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note Coaxial Cable Entry Panels, Coax and Grounding Connectors Technical Note Coaxial Cable Entry Panels, Coax and Grounding Connectors Surge Protection Solutions for PTC 2 Coaxial Cable Entry Panels, Coax

More information

Work in Substations - General

Work in Substations - General Work in Substations - General Summary: This document supports the Power System Safety Rules and its requirements assembled under Work in Substations General Category 3 and apply to all persons working

More information

Model 1756 Test Lead Kit

Model 1756 Test Lead Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you

More information

South African Nursing Council (Under the provisions of the Nursing Act, 2005)

South African Nursing Council (Under the provisions of the Nursing Act, 2005) South African Nursing Council (Under the provisions of the Nursing Act, 2005) e-mail: [email protected] web: www.sanc.co.za P O Box 1123, Pretoria, 0001 Republic of South Africa Tel: 012 420-1000 Fax:

More information

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS TESTS ON TRANSFORMERS 1. IR Values a) For 33/11 KV Power Transformer 2500 V megger is to be need. b) Power Transformer neutral Earthing is

More information

1 Introduction. 2 Hazards From Electricity

1 Introduction. 2 Hazards From Electricity Risk Assessment Application to Electrical Rigs A guide to assist the Competent Named person who will verify the safety of rigs consisting mainly of electrical equipment. 1 Introduction Every employer shall

More information

Unit ID: 482 Domain AUTOMOTIVE ELECTRICAL AND ELECTRONICS Title: Install and repair electrical lighting system of vehicles Level: 2 Credits: 6

Unit ID: 482 Domain AUTOMOTIVE ELECTRICAL AND ELECTRONICS Title: Install and repair electrical lighting system of vehicles Level: 2 Credits: 6 Unit ID: 482 Domain AUTOMOTIVE ELECTRICAL AND ELECTRONICS Title: Install and repair electrical lighting system of vehicles Level: 2 Credits: 6 Purpose This unit standard specifies the competencies required

More information

Low Voltage Asset Management (LVAM) The key to reliable and safe electricity

Low Voltage Asset Management (LVAM) The key to reliable and safe electricity Low Voltage Asset Management (LVAM) The key to reliable and safe electricity Archie Jaykaran Distribution Division Eskom SA Contents Change drivers Scope, Approach, Project status LV Planning and Design

More information

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13 Interfacing electrification and system reliability Roger White Professional Head of Electrification and Plant Rail Abstract Integration is the term given to ensuring that the different elements of an electrified

More information

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Grounding of Electrical Systems NEW CODE: Grounding and Bonding Grounding of Electrical Systems NEW CODE: Grounding and Bonding Presented By Scott Peele PE Grounding of Electrical Systems Outline Defining the Terms Why should I Ground? Types of Grounding Systems Separately

More information

SOUTH AFRICAN QUALIFICATIONS AUTHORITY. QUA LlFlCA TION:

SOUTH AFRICAN QUALIFICATIONS AUTHORITY. QUA LlFlCA TION: 38 No. 29271 GOVERNMENT GAZETTE, 6 OCTOBER 2006 No. 980 6 October 2006 SOUTH AFRICAN QUALIFICATIONS AUTHORITY (SAQA) In accordance with regulation 24(c) of the Regulations of 28 March 1998, th& Standards

More information

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV MEDIUM VOLTAGE SUBSTATION PRACTICES MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV MEDIUM VOLTAGE SUBSTATION PRACTICES This presentation covers some safety aspects

More information

BX7000 Multi-Access Gateway Getting Started Guide

BX7000 Multi-Access Gateway Getting Started Guide BX7000 Multi-Access Gateway Getting Started Guide This guide provides instructions on connecting the Juniper Networks BX Series 7000 Multi-Access Gateway to a network. For more information, see the BX7000

More information

Pontyclun Electrotechnical Training Ltd. (P.E.T. Ltd.)

Pontyclun Electrotechnical Training Ltd. (P.E.T. Ltd.) Pontyclun Electrotechnical Training Ltd. (P.E.T. Ltd.) Our highly-skilled and knowledgeable staff boast extensive industry experience as well relevant teaching qualifications. We are fully accredited by

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

About our Chairman cum- Managing Director

About our Chairman cum- Managing Director INTEGRATED GROUP Complete Range of Power Transmission and Distribution Equipments & Head office- SO 2-5, Second Floor, Amarjyoti Palace, Lokmat Square, Wardha Road, Nagpur-440012 Group E-mail ID : [email protected]

More information

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse How the National Grid System Operates Chris Gorman Lead Account Executive Syracuse 2 Parts of the Electric System Parts of the Electric System 1. Generating Station: Produces Electricity. 2. Transmission

More information

Good Industry Best Practice Safety Co-ordinator ordinator Guide

Good Industry Best Practice Safety Co-ordinator ordinator Guide Good Industry Best Practice Safety Co-ordinator ordinator Guide (Issue 2 26/07/2010) Recommended Safety Co-ordinator ordinator Training (Presentation & Guidance Notes) 1 Important Note: This package has

More information

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH PORTABLE POWER DISTRIBUTION SYSTEMS AND OTHER ELECTRICAL EQUIPMENT "ADDENDUM C" WORKING WITH 480 VOLT SYSTEMS

More information

National Certificate in Electrical Engineering (Electrical Appliance and Electronic Servicing) (Level 3)

National Certificate in Electrical Engineering (Electrical Appliance and Electronic Servicing) (Level 3) NQF Ref 1265 Version 3 Page 1 of 8 National Certificate in Electrical Engineering (Electrical Appliance and Electronic Servicing) (Level 3) Level 3 Credits 80 This qualification has been reviewed. The

More information

The Electrical Safety Regulation (pre and post 1 January 2014)

The Electrical Safety Regulation (pre and post 1 January 2014) The Electrical Safety Regulation (pre and post 1 January 2014) The following table provides an overview comparison between the Electrical Safety Regulation 2002 (the ESR 2002) current as at 1 July 2013

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS MIOSHA-STD-1313 (10/15) 6 Pages For further information Ph: 517-284-7740 www.michigan.gov/mioshastandards DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

More information

Trouble-shoot and repair faults in low voltage electrical apparatus and circuits

Trouble-shoot and repair faults in low voltage electrical apparatus and circuits UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits AS3000:2007 & AS3017:2007 Summary MANUFACTURING AND ENGINEERING DIVISI M & E UEENEEG108A TESTING Before any

More information

Financial Services. Postnet!Suite 24%

Financial Services. Postnet!Suite 24% ~~ ~ STAATSKOERANT, 13 SEPTEMBER 2002 No. 23831 103 NOTICE 1723 OF 2002 SOUTH AFRICAN QUALlFlCATlONS AUTtiORlW. (SAQA) in accordance with regulation 24(c) of the vational Standards Bodies Regulations of

More information

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED

More information

Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au

Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au ELECTRICAL RISKS AT THE WORKPLACE Heading FACT SHEET Overview This fact sheet provides general guidance for persons conducting a business or undertaking (PCBUs) and workers on managing electrical risks

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

Softstart. Changing of Printed Circuit Board PS S18-300. General...2 Please note!... 2

Softstart. Changing of Printed Circuit Board PS S18-300. General...2 Please note!... 2 Softstart Changing of Printed Circuit Board PS S18-300 5309 704-1 Rev E Juli-06 General...2 Please note!... 2 Identify the Printed Circuit Board that is going to be replaced...2 Replacing an older PCB

More information

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Title MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Duration 5 days Training Date MV, HV and EHV Switchgear Testing & Commissioning 5 20 24 Apr $3,750 Dubai, UAE In any of the 5 star

More information

OUTDOOR LED SCOREBOARD CARE & OPERATIONS MANUAL

OUTDOOR LED SCOREBOARD CARE & OPERATIONS MANUAL OUTDOOR LED SCOREBOARD CARE & OPERATIONS MANUAL 98 0000 11 REV 11 19 08 DISCLAIMER This publication is not a service manual. There are no user serviceable components. If you require service, please contact

More information

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services SpecialistS IN ELECTRICAL SUPPORT SERVICES TO MINING, UTILITIES & industry Ampcontrol is committed to supporting our customers to maintain efficient

More information

What the OHS Act says about the training responsibilities of constructors, employers, and supervisors

What the OHS Act says about the training responsibilities of constructors, employers, and supervisors REQUIRED Pull-out chart TRAINING Construction Health and Safety in Ontario The Occupational Health and Safety Act (OHS Act) requires constructors and employers to provide worker training. Specific requirements

More information

11. Assessment of service 12. S-phase supply 13. Water heaters NORTHERN TERRITORY OF AUSTRALIA ELECTRICITY BY-LAWS T ABLE OF PROVISIONS

11. Assessment of service 12. S-phase supply 13. Water heaters NORTHERN TERRITORY OF AUSTRALIA ELECTRICITY BY-LAWS T ABLE OF PROVISIONS NORTHERN TERRITORY OF AUSTRALIA ELECTRICITY BY-LAWS T ABLE OF PROVISIONS By-law PART I - PRELIMINARY 1. Citation 2. Repeal 3. Interpretation 4. Qualifications of inspector PART II - INSPECTORS PART III

More information

ENERGY NETWORKS ASSOCIATION. Electricity Industry EMF Measurement Protocol for High Field Areas

ENERGY NETWORKS ASSOCIATION. Electricity Industry EMF Measurement Protocol for High Field Areas ENERGY NETWORKS ASSOCIATION Electricity Industry EMF Measurement Protocol for High Field Areas Contents 1 Introduction 1.1 Background 1.2 High Field Areas 2 High Field Area - Generation Businesses 2.1

More information

National Certificate in Adult Education and Training (Level 5) with strands in New Zealand Environment, and International Environment

National Certificate in Adult Education and Training (Level 5) with strands in New Zealand Environment, and International Environment NQF Ref 0379 Version 3 Page 1 of 6 National Certificate in (Level 5) with strands in New Zealand Environment, and International Environment Level 5 Credits 59-60 Purpose The National Certificate in (Level

More information

Public Comment SOUTH AFRICAN QUALIFICATIONS AUTHORITY. QUALIFICATION: Master of Philosophy in Hospitality and Tourism Management

Public Comment SOUTH AFRICAN QUALIFICATIONS AUTHORITY. QUALIFICATION: Master of Philosophy in Hospitality and Tourism Management SOUTH AFRICAN QUALIFICATIONS AUTHORITY QUALIFICATION: Master of Philosophy in Hospitality and Tourism Management SAQA QUAL ID QUALIFICATION TITLE 91879 Master of Philosophy in Hospitality and Tourism Management

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

V1.8 0 - N ovember 2015. Distribution Network Asset Data Available To Third Parties

V1.8 0 - N ovember 2015. Distribution Network Asset Data Available To Third Parties V1.8 0 - N ovember 2015 Distribution Network Asset Data Available To Third Parties How To Request Data LinesearchBeforeUDig (http://www.linesearchbeforeudig.co.uk) This service is available 24/7 365 days

More information

Before installing unit, please carefully look over Installation Guide.

Before installing unit, please carefully look over Installation Guide. Thank you for purchasing the BassMaxx II. We are confident this product will help increase your trolling motor battery life, allowing you to spend more time fishing. We are proud of this patented system.

More information

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED Preparation: Safety Mgr Authority: Dennis Johnston Issuing Dept: Safety Page: Page 1 of 9 Purpose The purpose of the Electrical Safety program is to set forth procedures for the safe use of electrical

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Section B: Electricity

Section B: Electricity Section B: Electricity We use mains electricity, supplied by power stations, for all kinds of appliances in our homes, so it is very important to know how to use it safely. In this chapter you will learn

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

PowlVac Vacuum Integrity Tester

PowlVac Vacuum Integrity Tester Instructions IB-60025B PowlVac Vacuum Integrity Tester POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900 FAX (713) 947-4453 www.powellelectric.com

More information

CODE OF PRACTICE NINE

CODE OF PRACTICE NINE CODE OF PRACTICE NINE CODE OF PRACTICE FOR THE METERING OF IMPORT AND EXPORT ACTIVE ENERGY VIA LOW VOLTAGE CIRCUITS FOR NON-HALF HOURLY SETTLEMENT PURPOSES Issue 1 Version 5.0 DATE: 26 November 2009 Balancing

More information

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1

More information

SOUTH AFRICAN QUALIFICATIONS AUTHORITY (SAQA)

SOUTH AFRICAN QUALIFICATIONS AUTHORITY (SAQA) 24 No. 28840 GOVERNMENT GAZETTE, 19 MAY 2006 No. 458 19 May 2006 SOUTH AFRCAN QUALFCATONS AUTHORTY (SAQA) n accordance with regulation 24(c) of the National Standards Bodies Regulations of 28 March 1998,

More information

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited TABLE OF CONTENTS 1.0 Purpose and Scope...2 1.1 Methodology Purpose...2

More information

Video Camera Installation Guide

Video Camera Installation Guide Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide

More information

Co-location Interconnect Power Panel (CIPP) Installation Guide

Co-location Interconnect Power Panel (CIPP) Installation Guide Co-location Interconnect Power Panel (CIPP) Installation Guide Document INS-97xxxxxxx This guide covers the following part numbers- Trimm 97xxxxxxx Series Table of Contents Section 1 - General Information...

More information

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Lightning current simulation in the laboratory - parameters, procedures and test equipment - Lightning current simulation in the laboratory - parameters, procedures and test equipment - Dipl.-Ing. J. Schönau, Dr.-Ing. M. Naß, CE-LAB GmbH Prof. Dr.-Ing. F. Berger, Ilmenau University of Technology

More information

Litigation Services & Information

Litigation Services & Information Litigation Services & Information Laurence "Lo" Lehman, P.E. Lehman Engineering Company Lehman Engineering has been providing engineering, design, and consulting services for electrical power systems to

More information

Power products and systems. Intelligent solutions for power distribution Zone concept

Power products and systems. Intelligent solutions for power distribution Zone concept Power products and systems Intelligent solutions for power distribution Zone concept Securing continuous power supply ABB is one of the world's leading power and automation technology companies whose products,

More information

[Registered Qual & Unit Std Home page] [Search Qualifications] [Search Unit Standards]

[Registered Qual & Unit Std Home page] [Search Qualifications] [Search Unit Standards] [Registered Qual & Unit Std Home page] [Search Qualifications] [Search Unit Standards] All qualifications and part qualifications registered on the National Qualifications Framework are public property.

More information

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage

More information

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance WHITE PAPER Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance Overview Enphase has developed a new microinverter family that includes the M250 and new

More information

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Regulation IO-6.0: Electrical Safety Regulations

Regulation IO-6.0: Electrical Safety Regulations Regulation IO-6.0: Electrical Safety Regulations 6.1 Workmanship & Material 6.2 Electrical Conductors 6.3 Overcurrent Protective Devices 6.4 Precautions against Earth Leakage and Earthfault Currents 6.5

More information

South African Nursing Council (Under the provisions of the Nursing Act, 2005)

South African Nursing Council (Under the provisions of the Nursing Act, 2005) South African Nursing Council (Under the provisions of the Nursing Act, 2005) e-mail: [email protected] web: www.sanc.co.za P O Box 1123, Pretoria, 0001 Republic of South Africa Tel: 012 420-1000 Fax:

More information

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1

More information

BOARD NOTICE 269 OF 2013 FINANCIAL SERVICES BOARD FINANCIAL ADVISORY AND INTERMEDIARY SERVICES ACT, 2002

BOARD NOTICE 269 OF 2013 FINANCIAL SERVICES BOARD FINANCIAL ADVISORY AND INTERMEDIARY SERVICES ACT, 2002 STAATSKOERANT, 20 DESEMBER 2013 No. 37168 89 BOARD NOTICE 269 OF 2013 FINANCIAL SERVICES BOARD FINANCIAL ADVISORY AND INTERMEDIARY SERVICES ACT, 2002 AMENDMENT OF THE NOTICE ON QUALIFICATIONS, EXPERIENCE

More information

Live Working equipment from BSD - Germany

Live Working equipment from BSD - Germany Live Working equipment from BSD - Germany Hendrik Tänzer, Thomas Jordan Seminar Arbeid under spenning 13.-14.October 2009 Skjetten / Norge Location Berlin Großröhrsdorf Dresden Location BSD GmbH, Lutherstraße

More information

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide. www.zycoo.com

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide. www.zycoo.com SYS WAN LAN IP PHONE SYSTEM Series-U60 For Small and Medium Business Quick Installation Guide www.zycoo.com Table of Contents 1 Package Contents 2 Hardware Installation 2.1 Safety Precautions 2.2 Installation

More information

Circuit Electrical Testing

Circuit Electrical Testing Safe Isolation Procedure Circuit Electrical Testing Site Safety Management It is essential from the outset that effective management and control of the system, apparatus and equipment used on site is achieved

More information

TRAINING RESOURCE MANUAL NATIONAL SPECIALISED ELECTRICAL WORK RECORD OF WORK EXPERIENCE AND TRAINING UEENEEP024A UEENEEP017A. EE-Oz Training Standards

TRAINING RESOURCE MANUAL NATIONAL SPECIALISED ELECTRICAL WORK RECORD OF WORK EXPERIENCE AND TRAINING UEENEEP024A UEENEEP017A. EE-Oz Training Standards TRAINING RESOURCE MANUAL NATIONAL SPECIALISED ELECTRICAL WORK UEENEEP024A UEENEEP017A RECORD OF WORK EXPERIENCE AND TRAINING 1 CONTENTS Learner s Personal Details Page 3 Background Information Page 4 Definitions

More information

Dakota Energy Cooperative, Inc. POLICY STATEMENT

Dakota Energy Cooperative, Inc. POLICY STATEMENT Dakota Energy Cooperative, Inc. POLICY STATEMENT Subject: Member Owned Small Renewable Energy Policy No. 57 Rate and Interconnection Requirements Issue Date: May 21, 2008 Revised Date: December 16, 2014

More information

Technical Note Series

Technical Note Series Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment

More information

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

CHECKING AND TESTING ELECTRICAL INSTALLING WORK CHECKING AND TESTING ELECTRICAL INSTALLING WORK Department of Consumer and Employment Protection Energy Safety Preface It is a requirement of the Electricity (Licensing) Regulations 1991 that all electrical

More information

SERVICE - GENERAL Residential, Commercial, Industrial

SERVICE - GENERAL Residential, Commercial, Industrial PAGE 1 OF 9 USE: Rules and procedures for overhead or underground services. PREVIOUS REVISION 10-01-01 ORIGINATED 03-94 PREVIOUS NUMBER ER 1-290-B, 07-15-93 LATEST REVISION: Remove details of Facility

More information

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices 1 Union County Public Schools Facilities Department Electrical Safe Work Practices 2 Purpose In accordance with OSHA Standards 1910.331-335, safety-related work practices shall be used by Union County

More information

David O Brien, CMP Products ([email protected])

David O Brien, CMP Products (David.OBrien@cmp-products.com) David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

Electrical Shore Connections / Cold Ironing

Electrical Shore Connections / Cold Ironing STANDARD FOR CERTIFICATION No. 2.25 Electrical Shore Connections / Cold Ironing JULY 2014 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version

More information

Earthing Guidance Notes

Earthing Guidance Notes Central Networks Earthing Manual Section E2 Earthing Guidance Notes Version: 2 Date of Issue: September 2007 Author: Nigel Johnson Job Title: Earthing Specialist Approver: John Simpson Job Title: Head

More information

1. Franklin Rod Performance 2. LEC/DAS Performance

1. Franklin Rod Performance 2. LEC/DAS Performance THREE ESSENTIALS OF LIGHTNING PROTECTION: BONDING, GROUNDING AND SURGE PROTECTION by Richard Kithil, President and Orlando Alzamora, Vice-President National Lightning Safety Institute (NLSI) 1.0 Summary.

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

CAPACITOR BANK TESTING SWP

CAPACITOR BANK TESTING SWP 1. PURPOSE AND SCOPE The purpose of this Standard Work Practice (SWP) is to standardise and prescribe the method for testing Capacitor Banks including capacitors, tuning reactors and inrush limiting reactors.

More information

Summary of risks with conductive and nonconductive plastic pipes at retail petrol stations

Summary of risks with conductive and nonconductive plastic pipes at retail petrol stations Summary of risks with conductive and nonconductive plastic pipes at retail petrol stations Introduction Harold Walmsley, Harold Walmsley Electrostatics Ltd, 23/01/2010 This note summarises my views on

More information

About the HotWire 7900 10-Slot Standalone Shelf

About the HotWire 7900 10-Slot Standalone Shelf TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed

More information

Earth Fault Detection Basics in Theory

Earth Fault Detection Basics in Theory Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star

More information

Powerline Network. RPL-85 User Manual RPL-85. Powerline Ethernet Bridge V1.0.0. 2009. All rights reserved. Page 1

Powerline Network. RPL-85 User Manual RPL-85. Powerline Ethernet Bridge V1.0.0. 2009. All rights reserved. Page 1 RPL-85 User Manual RPL-85 Powerline Ethernet Bridge V1.0.0 2009. All rights reserved. Page 1 PREFACE This document describes installation of the RPL-85 Ethernet Bridge Network products. Please read this

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information