Installation & Maintenance Manual
|
|
|
- Caren Banks
- 10 years ago
- Views:
Transcription
1 Installation & Maintenance Manual
2 Installation and maintenance Manual Contents Introduction 2 Cabling the unit 31 General overview 2 Connecting the extensions 31 Safety Precautions during installation and system upgrades 3 CCU connections 33 Electrostatic precaution (ESP) PSTN connection for the ADSL line 3 33 Lightning and surge voltage protection Door Intercom 33 3 Installation checklist 6 Doorstrike 33 Installing the Central Control Unit 7 Connecting a MOH (Music On Hold Module) 34 CCU Location(CCU) 7 Mounting the CCU 7 CCU Mounting bracket clearances 8 Mounting the CCU 9 Modules located in the CCU 10 Module location 10 System Expansion 11 Installing the Backplane wall bracket 11 Mounting the CCU with two brackets 11 Mounting the Backplane 12 Expansion Modules 13 Installing an Expansion module 14 Analogue line module 15 Installing the Analogue Module in the CCU 15 Basic Rate ISDN expansion module 17 Installing the Basic Rate ISDN Module in the CCU 17 System ISDN settings 19 T 0 interface termination 19 S 0 interface termination 19 Voic module 20 Back up Voice Module voice messages and Greetings 20 Primary Rate Interface 21 Connecting the battery backup unit to the system 22 Connecting the Battery 23 Featurephone V16 24 V16 Featurephone connections (underside of phone) 24 Featurephone V8 25 V8 Featurephone connections (underside of phone) 25 Attaching the Featurephone desk plinth (V8 and V16) 26 V16 expansion console 27 Feature phone with console 27 Clip, Plinth and installation of the V16 expansion console 28 Wall-mounting a Featurephone 29 Door Intercom 30 Connecting a PA (public Address) amplifier 34 Connecting a PC or Printer to the Serial Port 34 Ports Module MDF Connections 35 Broadband Module MDF Connections 36 Options Module MDF Connections 37 Central Bell 37 External Extension 37 Expanding an Existing system 38 Installing an additional Network (Analogue or ISDN) module 38 Installing additional modules 38 Maintenance procedures 39 Hot Swapping faulty modules 39 Replacing a faulty Module MDF 40 Replacing Faulty PCBs 41 Replacing the 008 extension board 41 Replacing the CCU Control PCB 42 Power supply unit spare fuse 43 Replacing the Power Supply Unit 44 Replacing the CCU MDF 45 Power fail 46 Analogue 46 ISDN 46 Power up and test 47 Switch on 47 Commissioning 47 Programming 48 Recommendations for customer training 56 Troubleshooting 57 Technical specification 58 INDEX 61 1
3 Installation and maintenance Manual Introduction This document describes the practices to be adopted by field engineers during installation and maintenance of the BT Versatility. A more detailed description of the product, along with customer programmable facilities and features, may be found in the BT Versatility Owner's Manual, Broadband Guide and Internet Guide which should be read in conjunction with this document. General overview The BT Versatility is a new converged PBX and Data product, which can be connected to Analogue, ISDN and LAN networks. The BT Versatility is a hybrid PABX/key-system, which may be equipped with Featurephones (V8 or V16) or standard two wire DTMF telephones. Extensions can also be equipped with Fax or Answering machines. The BT Versatility is modular in construction and can be upgraded by adding various system expansion modules (Ports Modules, Options Module, Music on Hold module and Broadband Module). The BT Versatility allows Voice connectivity to ISDN and Analogue MF exchange lines. The BT Versatility may be configured with up to four internal S-Bus interfaces for connection to approved ISDN apparatus. The BT Versatility is a versatile, easy-to-use system, which is simple to install and maintain. The BT Versatility Broadband Module. This provides Data connectivity to the Internet via ISDN or ADSL lines. It provides an internal LAN. It also provides VoIP trunks which allows voice calls from extensions to be carried over a Broadband Voice Service Provider (such as BT Broadband Voice) or a managed IP network. The BT Versatility Internet Module. This provides Data connectivity to the Internet via ISDN or ADSL lines. It also provides an internal LAN. Note: This module is no longer supplied. The CE Marking on this equipment indicates compliance with the following: This device conforms to Directive 1999/5/EC on Radio Equipment and Telecommunications Terminal Equipment as adopted by the European Parliament And Of The Council. 2
4 Installation and Maintenance Manual Safety Precautions during installation and system upgrades Always unplug or isolate the mains supply when installing or upgrading the system. After installing the central control unit (CCU) and all required modules, ensure that the following points are checked before switching the mains power on: The cabled extensions have a DTMF telephone or a (V8/V16) Featurephone connected. The CCU cover is in place and locked. After switching on the Mains allow approximately 30 seconds for the CCU to go through its power up routine. Electrostatic precaution (ESP) The BT Versatility contains electrostatic components. To ensure long-term reliability of the system, electrostatic precautions should be taken when handling any of the system PCBs that are not enclosed in plastic. An ESP pillar is located on the CCU MDF. Lightning and surge voltage protection Extension cabling should not be exposed to high voltage surges, (for example, surges induced by lightning or neighbouring high current-carrying cables). If this is a possibility, external protection of the Main Equipment and Extensions using earthed line surge protectors is essential. 3
5 Installation and maintenance Manual BT Versatility - Packages, Spares and Maintenance Items BT Versatility Pro. Plus(Includes System, VM, 1M,2V8) BT Code BT Vers Pro Plus 2+8 Digital VDS BT Vers Pro Plus 4+16 Digital VDS BT Vers Pro Plus 6+24 Digital VDS BT Vers Pro Plus 8+32 Digital VDS BT Versatility Advanced Digital (System, 8 Port VM Pro, 4V8 and V16 with the 12/32 ) N/A BT Vers Adv 2+8 Dig VDS BT Vers Adv 6+16 Dig VDS BT Vers Adv PRI+16 Dig VDS BT Vers Adv PRI+24 Dig VDS BT Vers Adv PRI+ 32 Dig VDS BT Versatility Voice Digital (Includes System, 2V8) N/A BT Vers Voice 2+8 Dig VDS BT Vers Voice 6+16 DigVDS BT Vers Voice PRI+16 Dig VDS BT Vers Voice PRI 24 Dig VDS BT Vers Voice PRI+32 Dig VDS BT Versatility Advanced Analogue (System, 8 Port VM Pro, 4V8 and V16 with the 12/32 ) N/A BT Vers Adv 2+8 Analog VDS BT Vers Adv 6+16 Analog VDS BT Vers Adv 8+24 Analog VDS BT Vers Adv Analog VDS BT Versatility Voice Analogue (Inculdes System, 2V8) N/A BT Vers Voice 2+8 Analog VDS BT Vers Voice 6+16 Analog VDS BT Vers Voice Analog VDS BT Vers Voice Analog VDS Versatility Value Add Packs N/A BT Versatility VM & 4xV8 Phone Pack VDS BT Versatility Phone Pack 1-2 x V8 VDS BT Versatility Phone Pack 2-4 x V8 VDS BT Versatility Phone Pack 3-2 x V16 VDS BT Versatility Phone Pack 4-6 x V VDS BT Versatility Phone Pack 5 - V16 & V16 Console VDS Additional items N/A BT Versatility Digital Line Module ISDN VDS BT Versatility Analogue Line Module VDS BT Versatility Voic 2P VDS BT Versatility Voic 4P VDS BT Versatility Broadband Module (2 VoIP Trunks) VDS BT Versatility BBU VDS
6 Installation and Maintenance Manual BT Versatility 8 Port Extension Module VDS BT Versatility Hospitality Application VDS BT Versatility Options Module VDS BT Versatility V Telephone VDS BT Versatility V8 Featurephone BT Versatility V16 Featurehone VDS BT Versatility V16 XP Expansion Console VDS BT Versatility Door Intercom VDS BT Versatility Expansion Backplane VDS BT Vers V/ Pro 8P VDS BT Vers EMOH Module VDS BT Vers PRI Module VDS BT Vers M/board (40 Port) VDS BT Vers PSU (40 P) VDS BT Vers PRI Module Refurb BT Vers V/mail Pro 8P Refurb BT Vers M/board (40 P) Refurb BT Vers PSU (40 P) Refurb Maintenance items N/A BT Versatility V Featurephone MTC BT Versatility V8 Featurephone MTC BT Versatility V16 Featurehone MTC BT Versatility V16 XP Exapansion Console MTC BT Versatility Main System MDF Top Cover MTC BT Versatility Main System Front Cover MTC BT Versatility Module Access Door Cover MTC BT Versatility Wall Bracket (for CCU or Backplane) MTC BT Versatility System PSU - PCB Card only MTC BT Versatility Main CCU Extension Card MTC BT Versatility Motherboard MTC BT Versatility CCU MDF Card MTC BT Versatility V.24 Cable - incl DTYPE MTC BT Versatility 2m RJ45 Cable ISDN & Interet Mod WAN MTC BT Versatility CCU Housing screw 1/4 turn 4pk MTC BT Versatility BBU Blanking Plate MTC BT Versatility Expansn Backplane Bracket & Screw Pk MTC BT Versatility 8 Port Extension Module MDF Cover MTC BT Versatility 8 Port Extension Module (no MDF) MTC BT Versatility 8 Port Extension Module MDF only MTC BT Versatility Broadband Module MDF Cover MTC BT Versatility Broadband Module (no MDF) MTC BT Versatility Broadband Module MDF MTC TBA TBA TBA BT Versatility Options Module MDF Cover MTC BT Versatility Options Module (no MDF) MTC
7 Installation and maintenance Manual BT Versatility Options MDF MTC BT Versatility Mod Retentn Long 1/4 turn Screw MTC BT Versatility V16 Console to V16 Connection Cable MTC BT Versatility V16 PSU MTC BT Versatility PSTN Module MTC BT Versatility ISDN2 Module MTC BT Versatility Voice Mail Module 2 Port MTC BT Versatility Voice Mail Module 4 Port MTC BT Versatility Battery Backup Module MTC BT Versatility Door Intercom MTC Installation checklist Carry out the following steps to install the system: FIRST, read the safety and precaution information on page 3 carefully. SECOND, mount the Main Equipment as detailed in the section on page 7 THIRD, install the Network and Expansion modules as required At least one Analogue Line Module must be installed to access the Analogue network. At least one ISDN Basic Rate Module or ISDN Primary Rate Module must be installed to access the ISDN network. A Ports module must be installed if the following is required: More than 8 Extensions More than four Analogue Lines More than two ISDN Basic Rate Accesses More than one ISDN S-bus If no options module is installed "External Music on Hold" can be provided through the MOH Module connected to an extension. See page 34 for details on connection of the unit. A Broadband module must be installed if an internal LAN or connection to an ADSL Line is required A Broadband module must be installed if VoIP trunks are required. A Broadband module requires a minimum system software version of 677 A Voice Module must be installed to provide Voic or Auto Attendant functionality. The Battery Back Up Module and battery must be installed if battery back up is required. FOURTH, cable the Extensions to the Main Equipment and install the system Featurephones and standard telephones as detailed in the Cabling Section Page 31. This section also covers installation the following: Long-line Extension, Door Intercom, Doorstrike, Central Bell, External Music-on-Hold, Public Address V24 Interface to provide Call Logging. FIFTH, cable the Analogue and ISDN Line connections as detailed in the cabling section Page 31. SIXTH, commission the system and provide customer training as detailed in the Commissioning section Page 47 and 48. 6
8 Installing the Central Control Unit BT Versatility Installation and Maintenance Manual CCU Location(CCU) The CCU is intended for installation in a residential or office-type environment. It needs to be mounted at a convenient working height on a dry, flat wall. The normal height is 1.5 m from the floor to the bottom of the CCU case. Do not site the CCU where it will be subjected to excessive levels of heat, dust, damp or high humidity. Locating the equipment near sources of electromagnetic radiation, such as heavy electrical switch gear, lift machinery or electric arc welders, should be avoided. Allow at least 150 mm of free space all around the CCU for ventilation. The CCU needs to be located within two metres of a dedicated mains power supply outlet. The CCU must not share the same mains supply socket with any other electrical appliance. Mounting the CCU When a suitable location has been found, mark the screw locations on the mounting surface, using the mounting bracket provided. If the CCU is being mounted on masonry or plasterboard, suitable wall plugs must be used. Drill and plug four holes in the wall at the marked locations. The holes should be deep enough to accept a 2.5cm screw. Wall mount bracket 7
9 Installation and maintenance Manual CCU Mounting bracket clearances The main unit is mounted on a wall using the bracket supplied and should have top and side clearance as shown below. CCU Mounting Bracket 300mm If the system is to be equipped with a Ports, Options or Broadband module then two mounting brackets need to be installed. CCU Bracket + Backplane Bracket 300mm min 300mm min 8
10 Installation and Maintenance Manual Mounting the CCU The CCU is mounted on the bracket by sliding it on from the left hand side. The marks on the side of the CCU must be lined up with the flanges on the wall bracket as shown below before sliding the CCU into place. When you slide it fully to the right-hand side of the bracket the CCU is automatically locked in place. 300mm min line marks up with flanges Flanges To remove the CCU depress the lock located on the left-hand side of the wall bracket. Slide the CCU to the left to remove it from the bracket. 9
11 Installation and maintenance Manual Modules located in the CCU There are a number of modules that can be installed in the CCU. Analogue Line Module (Coloured Black). This provides 2 Analogue exchange lines. Up to two of these modules can be installed in the CCU to provide two or four Analogue lines. Digital Line Module (Coloured Red). This card provides one ISDN 2 Basic Rate Interface. The same module is used for the network T interface and the internal S-bus. Up to two of these modules can be installed in the CCU providing one or two Basic Rate Interfaces. There are two slots in the CCU for the Network modules. If required one slot can be equipped with an Analogue module and the other with an ISDN Module. Voice module 2 port, 4 port or the enhanced 8 port (Coloured Blue). Only one of these modules can be inserted in a unit. Primary Rate ISDN module (Coloured Yellow). This module provides for a Primary rate ISDN interface. Up to 30 B-channels can be provided. When a Primary Rate Interface is installed, the unit can be further equipped with one or two Analogue modules or one or two ISDN Basic Rate modules to provide backup in the event of the Primary Rate interface failing. Module location The Network, Voice and Primary Rate module locations in the CCU are indicated below. Primary Rate ISDN Network Module 1 Analogue lines 1 and 2 or the First Basic Rate ISDN Line Voice Module Network Module 2 Analogue lines 3 and 4 or the second Basic Rate ISDN Line or the Internal ISDN S 0 Circuit 10
12 Installation and Maintenance Manual System Expansion To equip the switch with more than 8 extensions or to add an Broadband or Options module, a backplane, mounted on a second wall bracket, is needed. The power must be disconnected to install the backplane or expansion modules. Installing the Backplane wall bracket The CCU and Backplane brackets are identical. However when both are installed the backplane bracket is inverted so that it meshes closely with the CCU bracket. Locate the second bracket and mark the screw holes. Drill and plug the holes in the wall at the marked locations. The holes should be deep enough to accept a 2.5cm screw. Mount the second bracket ensuring the two brackets are correctly interlocked and that sufficient clearance is provided on all sides. Mounting the CCU with two brackets Slide the CCU on to the brackets from the left-hand side. Ensure that the locking mechanism is activated. 300mm min 11
13 Installation and maintenance Manual Mounting the Backplane Slide the backplane on from the right hand side. Ensure the connector is fully mated with the CCU. Securing the backplane to the wall bracket A mounting screw is used to securely locate the backplane on the wall bracket. This provides additional rigidity to ensure the backplane and CCU connectors do not move. Remove the fourth and fifth cover from the backplane. Locate the backplane on the bracket and connect it to the CCU. The backplane must be fully connected to the CCU to correctly locate the mounting screw hole. Insert the screw into the pillar on the bracket, which can be seen through the backplane mounting screw hole. Mounting screw hole 12
14 Installation and Maintenance Manual Expansion Modules There are three types of expansion module that can be installed on the back plane. These are the Ports Module, the Broadband Module and the Options Module. All these modules are installed in the same way. Modules are supplied in two parts. The MDF, which is connected to the backplane, and the module which is inserted into the MDF. The Ports MDF is also equipped with two connectors for the Analogue and /or the ISDN Basic Rate modules. The power must be disconnected when installing the Backplane or expansion modules Module with MDF Module and MDF separated 13
15 Installation and maintenance Manual Installing an Expansion module Install the Backplane as described on page 12. Install the MDF in the first free left-hand slot on the backplane. Lock the MDF in place by pushing the lock bar upward using a screwdriver. Push up to lock Lift the MDF cover and install the module. 14
16 Analogue line module The Analogue Line module contains circuitry for 2 Analogue Lines. BT Versatility Installation and Maintenance Manual The module is coloured BLACK and it can be installed in the CCU and also on the Ports MDF. Analogue Module Installing the Analogue Module in the CCU Remove the cover of the CCU. Insert the Analogue module in the Network slot or slots in the CCU. The left -hand slot is the first module position Remove the cover. Locate the Module First network module 15
17 Installation and maintenance Manual To Locate the Analogue Module in the Ports Module: Remove the Ports Module by firstly opening the Ports MDF cover Open the Ports module and remove it from the MDF Insert the Analogue Module (or modules) on the MDF connectors The upper slot is the first module position First network module 16
18 Basic Rate ISDN expansion module The ISDN Basic Rate Module provides one Basic Rate ISDN circuit (2B+D). BT Versatility Installation and Maintenance Manual The module is coloured RED, and can be installed in the CCU and also in the Ports MDF. Installing the Basic Rate ISDN Module in the CCU Remove the cover of the CCU as shown. Insert the Basic Rate ISDN module in the Network slot or slots in the CCU as shown: Digital Line Module (ISDN 2) First network module 17
19 Installation and maintenance Manual To Locate the Digital Line Module (ISDN 2) in the PORTS module Remove the Ports Module by firstly opening the Ports MDF cover Open the Ports module and remove it from the MDF Insert the Digital Line Module (or modules) on the MDF connectors The upper slot is the first module position The top connector is for the first module that connects to the Network only. The lower connector is for the second module. This can be an ISDN 2 Network connection or an internal ISDN S-bus connection First network module Second Module. Can be external T or internal S 18
20 Installation and Maintenance Manual System ISDN settings The system can be configured with 8 Basic Rate ISDN interfaces. Half of these can be configured for internal S-bus operation. The second interface on the CCU and each of the Ports Modules can be programmed as S-bus interfaces for ISDN to-the-desk. T 0 interface termination An ISDN bus must be terminated twice, once at the start and once at the end of the bus. The Network Terminating Equipment (NTE) will provide the termination at the start of the bus. The end termination is also provided by the NTE if the BT Versatility is directly connected to one of the NTE RJ45 sockets. If ISDN 2 extension cabling and sockets are provided between the NTE and the switch the end terminating resistor will normally be provided by an ISDN type 2 RJ45 line jack. In both of these cases BT Versatility T 0 interface does not require the terminating resistor to be connected and the associated switches in the MDF associated with the T 0 interface must be set to OFF (Default). NOTE: In the case of structured cabling if no end termination is provided, the associated switches in the MDF associated with the T 0 interface must be set to ON. S 0 interface termination An ISDN S-bus must be terminated twice, once at the start and once at the end of the bus. The BT Versatility S 0 interface emulates the Network Terminating Equipment (NTE) and consequently is always terminated with 100 ohm resistance. In this case the switches associated with the interface in the MDF must be set ON. 19
21 Installation and maintenance Manual Voic module The Voice module is coloured BLUE It is located in the Voice Module slot in the CCU. There are three versions. Two Port with 2 hours capacity, 4 port with 4 hour capacity and 8 port with 20 hours capacity. A label identifies the 3 different modules. The label location is indicated in the drawing below. The 8 port version requires the system Motherboard to be the Universal (40 Port) type and to have a minimum system software version of 567. Module identification label Back up Voice Module voice messages and Greetings The ability to back up all the voice messages and greetings recorded on the voice module is available, so that they are not lost if the system software is upgraded. Before the software download is started the voice module information is retrieved using that option in Remote Management Software. Once this is done the voice module is effectively deactivated, therefore it is unavailable to users trying to record messages until the software download is completed and the voice module information restored back to the system. The voice module is now re-activated and available for use and all the greetings and messages present before the software download are still present. 20
22 Primary Rate Interface The Primary rate ISDN Module (30B+D) is coloured Yellow It is located in the Primary rate ISDN Slot in the CCU Minimum system software required for PRI working is version 567. BT Versatility Installation and Maintenance Manual 21
23 Installation and maintenance Manual Connecting the battery backup unit to the system The Battery back up provides operation of an system with 8 external calls and 3 internal calls running for approximately 40 minutes in the event of a power failure. The battery will support 11 erlangs of voice traffic for 40 minutes. An erlang is a measure of telephony traffic. 1 erlang = 1 circuit fully occupied for 1hour The Battery back up consists of the 12 V battery and the charger unit Before installing the battery charger unit ensure that the system is powered down by disconnecting the mains. The life expectancy of the battery in standby use is 3 to 5 years. To install the unit, remove the blanking cover on the left side of the CCU. Open the CCU main cover by releasing the four quarter turn screws Slide the BBU in about half way. There are three cables connected to the charger unit. One with a connector, which connects to the PSU, and two with spade connectors which are connected to the battery. Connect the cable with the connector to the PSU. Thread the two cables for the battery up the cable guide to the battery compartment. Push the charger unit home. Replace the CCU cover. Battery charger connector on the PSU 22
24 Installation and Maintenance Manual Connecting the Battery Ensure the battery switch on the BBU unit is turned off. This switch does not turn off the mains supply. The mains is disconnected by unplugging the mains cord Insert the battery into the battery cavity in the CCU Connect the cables from the battery charger to the battery ensuring that the cables are connected correctly. Red cable to Red battery terminal, black cable to Black battery terminal Turn the battery charger switch on. Reconnect the mains. Led Indicators A status LED on the BBU is provided. GREEN indicates the unit is running from mains power and the battery is charging or fully charged. ORANGE indicates the unit is running off the Battery RED indicates that the battery is discharged Flashing RED indicates the battery is disconnected and the switch is running from the mains 23
25 Installation and maintenance Manual Featurephone V16 Secrecy Key Hands-free and light Volume Keys 4 Function Keys: Programming Messages Directories ISDN Message waiting/ Ringing indicator Handset 6 Display Keys 16 programmable keys. Numeric Keypad Clear Key Scroll / Edit keys V16 Featurephone connections (underside of phone) All V16 Featurephones are supplied with a 5v DC Power transformer V16 Console socket Handset connector Line cord connector Data Port Headset Port DC Adapter connector 24
26 Installation and Maintenance Manual Featurephone V8 Hands-free and light Secrecy Key Volume Keys 4 Function Keys: Programming Messages Directories ISDN Message waiting/ Ringing indicator Handset 6 Display Keys 8 Programmable keys. Numeric Keypad Clear Key Scroll / Edit keys V8 Featurephone connections (underside of phone) Handset connector Line cord connector DC Adapter connector Data Port Headset Port 25
27 Installation and maintenance Manual Attaching the Featurephone desk plinth (V8 and V16) Wall mount Plinth position Plinth position 35 Plinth position 20 Position at 35 degrees Position at 20 degrees 26
28 Installation and Maintenance Manual V16 expansion console The V16 featurephone can be equipped with a 32 key module. This provides 32 additional programmable keys. Up to eight V16 featurephones can be equipped with this module. From the system programming menus you program which extensions are equipped with this module. V 16 expansion console Feature phone with console To connect the V16 Console to a Featurephone (V16 only) Use the 15cm cord to connect the DSS to the base of the V16 Featurephone. The Console connector is marked on the base of the Featurephone. Additional power must be supplied to the Featurephone. This is done by connecting the 5V power supply to the DC jack on the base of the Featurephone. 27
29 Installation and maintenance Manual Clip, Plinth and installation of the V16 expansion console Cord Rail 15 cm cord (RJ11 connector) NOTE: For the 20 degrees position or the 35 degrees position relate to page
30 Installation and Maintenance Manual Wall-mounting a Featurephone The phone plinth is inverted on the base to wall mount the phone. Locate, drill and plug the 2 screw locations as shown below. The holes should be deep enough to accept a 2.5 cm screw. Insert the two screws leaving sufficient space to clip the base over them. Locate the phone and base over the screws. Line cord rails 150 mm Featurephone in Wall Mount position V16 and Console in Wall Mount position 29
31 Installation and maintenance Manual Wall hook when the V8/V16 is in a 20 degrees or 35 degrees position Wall hook when the V8/V16 is wall mounted. Door Intercom The door intercom is connected to extension 23, the fourth extension on the CCU. Door intercom bracket Mounting screw Connect the single pair from the door intercom to the AB connections on extension 23. The system must be programmed to recognise the Door intercom. Refer to the BT Versatility Owner's manual for programming details. 30
32 Installation and Maintenance Manual Cabling the unit All Line and Extension circuit cabling is inserted from the top of the unit. There are breakouts as shown on the top of the unit to facilitate routing of cables into the MDF area. Cabling Break outs Connecting the extensions It is recommended that all extensions be cabled with 2 pairs. The Featurephones use all four wires and standard phones use the a,b pair only. Do not exceed the following resistance or distance limits when connecting extensions to the System Unit. (The distances listed assume 0.5mm-tinned copper conductor is used). 67 Ohms, or 400 metres, for system Featurephones. 336 Ohms, or 2 kilometres, for a standard telephone 336 Ohms, or 2 kilometres, for a standard telephone connected to the external extension on the Options Module The Extension cables must be of twisted-pair construction, using insulated tinned copper wires of nominal 0.5 mm 2 cross-sectional area. Category 5 cable must be used for all ISDN installations. It is important that this size and type of wire is correct since incorrect types can result in unreliable connections. Care should be taken to ensure that the cabling complies with all relevant cabling requirements. Run cable from each Extension location to the Main Equipment. Pass the cable through the cable entry hole in the CCU or Expansion Module and terminate the Extension wiring at the appropriate connector in accordance with the table below. 31
33 Installation and maintenance Manual Four wires per Extension are connected at the Main Equipment. Spare wires must be neatly laid back away from the connectors. To prevent cross talk or interference, cable pairs should not be split or the spare wire of cable pairs used. All Extensions should connect into standard line jack units. Extension cabling should not be exposed to high voltage surges, (for example, surges induced by lightning or neighbouring high current-carrying cables). If this is a possibility external protection of the Main Equipment and Extensions using earthed line surge protectors is essential. Connector pin- out Function RJ 12 pin out A Speech Pin 2 B Speech Pin 5 C Data Pin 1 D Data Pin 6 Standard 4-Wire IDC Krone connector A Speech - LJU Pin 2 B Speech - LJU Pin 5 C Data - LJU Pin 1 D Data - LJU Pin 6 32
34 CCU connections The CCU has the following connectors:- BT Versatility Installation and Maintenance Manual Eight four way Krone connectors for the extensions Two four way Krone connectors for the Analogue Lines. Two lines are terminated on each connector. Three RJ 45 connectors for the Basic rate ISDN interfaces. Two T 0 network connections and one Internal S 0 connector. An RJ 45 for the ISDN Primary Rate interface PRI. RJ 11 connector for Serial Interface V Serial port connector RS 323 (V24-2). A 2 position screw terminal for a doorstrike connection DS An ESP connector. A reset switch is provided which provides a warm reset. Two 2 pole switches are provided which provide the 100 ohm terminating resistance for the ISDN Basic Rate terminations, SW1 and SW2. PSTN connection for the ADSL line When a Broadband Module is provided an additional cable is supplied to allow the connection from the ADSL filter/splitter directly to the PSTN connection. Door Intercom The door intercom is cabled to extension 23, the fourth extension on the CCU. To operate the door intercom it must be programmed in system programming. See the Programming section of the Owner s manual. Doorstrike The doorstrike port provides a closed relay contact when in the operated condition. The relay contact is designed for low voltage DC equipment and should not be used for any voltages greater than those specified within the technical specification. 33
35 Installation and maintenance Manual Connecting a MOH (Music On Hold Module) Any of the extensions on the system, with the exception of the programming position, can be programmed as the external music on hold position. The MOH Module is connected to the a,b pair of the extension. The MOH Module is an optional component and must be ordered in addition to the system The MOH Module may be used with 40 extension Hotel Software Build 473 (or later) The MOH Module may be used with 32 extension System Software Build 474 (or later) The MOH Module may be used with all Systems provided they are running above software versions or later The MOH Module provides an isolation barrier between the Extension Port and the Music Source and it MUST be installed if an External Music Source is being connected to an Extension Circuit The MOH Module contains: 1. An adhesive pad for mounting in the MDF area of the CCU (see diagram) 2. A bare wire lead for connection to the AB connectors of an extension port 3. A 3.5mm Stereo jack for connection to the External Music Source Installation and connection 1. Open the MDF Cover of the CCU 2. Remove the MOH Module from packaging 3. Ensure clear access to the MOH fitting position (as below) 4. Remove Adhesive Backing paper from MOH Module 5. Fit MOH Module using Adhesive Pad in area shown 6. Fit with cables exiting to Right Side as shown below 7. Route Extension cable to preferred extension on the CCU or Ports module 8. Connect cable to AB port on extension using KRONE tool 9. Route the 3.5mm Stereo Jack connector to the Music Source external to the system, and connect source. 10. Complete any cabling and close the MDF. 11. Program the External MOH Extension Source 11.1 Programming / System 11.2 Music on Hold / Select External Source 11.3 Select External MOH Position 12. Confirm operation and audio levels are satisfactory. Connecting a PA (public Address) amplifier Any of the extensions on the system, with the exception of the Long Line extension on the Options module and the programming position, can be programmed as a PA position. The PA is connected to the a,b pair of the extension. Connecting a PC or Printer to the Serial Port A 2 metre cord with a 4 way RJ11 plug on one end and a 6 way RJ plug on the other is provided. An RJ to DB9 adapter is also provided. Connect the cord to the 4 way RJ11 connector on the CCU. Connect to the PC using either the 6 way RJ plug or the cord and DB9 converter as required. 34
36 Ports Module MDF Connections The connections on the Ports MDF are shown below. There are eight four-way Krone connectors for the extensions BT Versatility Installation and Maintenance Manual Two four-way Krone connectors for the Analogue Lines. Two lines are terminated on each connector. Three RJ 45 connectors for the Basic rate ISDN interfaces. Two T 0 network connections and one Internal S 0 connector. Two 2 pole switches are also provided for the 100 ohm terminating resistance for the ISDN Basic Rate accesses, SW1 and SW2. 35
37 Installation and maintenance Manual Broadband Module MDF Connections The Broadband module has a built in ADSL modem. To connect to an ADSL line use the gray lead provided to connect between the ADSL connector on the MDF and the data port on the splitter. If connecting to a managed IP network use the blue cable to connect between the 10/100 BaseT Wan connector and the external router / modem. See page 49 for basic router programming. There are six indicators (LEDs) on the MDF cover. Heartbeat steady to indicate normal processor activity ADSL - a solid light indicates ADSL line synchronisation flashes with activity. LAN 1 - a solid light indicates an Ethernet connection flashes with activity. LAN 2 - a solid light indicates an Ethernet connection flashes with activity. LAN 3 - a solid light indicates an Ethernet connection flashes with activity. LAN 4 - a solid light indicates an Ethernet connection flashes with activity. There is an additional indicator inside on the MDF. This is the WAN indicator - a solid light indicates an Ethernet connection flashes with activity. 36
38 Installation and Maintenance Manual Options Module MDF Connections The options module is equipped with a stereo jack for an external Music on hold input. Krone IDC connectors are provided for the Central Bell and the External extension. The Central bell and the external extension are cabled with extension cabling. They are connected with a single pair a,b. Central Bell The Central Bell is cabled by running a cable pair from the central bell IDC on the Options Module to a master line jack unit. Bells/tone callers can then be connected to the line jack unit or hard-wired to LJU terminals 3 and 5. External Extension This port is designed to operate long line extensions up to a distance of 2 kilometres away from the main unit and is approved for connection of 2-wire external extensions using PTO network cabling. Cable limitations 2-wire external extension = 2 kilometres maximum cabling distance or 3 db at 1600 Hz. The cable route should not be exposed to high voltage surges, such as lightning. Note: These figures assume the use of 0.5mm 2 diameter telephone wiring. All Extensions should connect into standard line jack units. Extension cabling should not be exposed to high voltage surges, (for example, surges induced by lightning or neighbouring high current-carrying cables). If this is a possibility external protection of the Main Equipment and Extensions using earthed line surge protectors is essential. 37
39 Installation and maintenance Manual Expanding an Existing system Modules may be removed and re-inserted in a system without disconnecting the power. See page 39. However if additional modules are being installed in a working system it is necessary to power the system down before installing an MDF or Backplane. If additional network modules are to be installed in spare slots, the system needs to be reset before the switch recognises the new modules. Installing an additional Network (Analogue or ISDN) module Modules can be installed in spare slots on the system without powering the system down. However the module will not be activated until the system is reset. This can be achieved by pressing the reset button on the CCU MDF. Pressing the reset button will invoke a warm reset and clear any calls in progress Installing additional modules The system must be powered down before installing an additional MDF on the Backplane. When the MDF is installed it is recommended that the Module, and any additional Network modules that may be required, be installed before the system is powered up. When the system is powered up the additional modules will be recognised by the system. The power must be disconnected before installing an MDF or Backplane. If Battery Back up is provided ensure the BBU switch is off and the mains is disconnected. 38
40 Installation and Maintenance Manual Maintenance procedures Faults can be rectified on site by replacing faulty modules or PCBs Hot Swapping faulty modules The Network modules can be replaced without powering the system down. If a Network module is replaced by the same type of module e.g. Analogue by Analogue, the switch will return to normal operation when the new module is inserted If a Network Module is to be replaced by a different type of Network Module (e.g. an Analogue module replaced by an ISDN module) the system must be reset, by pressing the reset switch in the CCU MDF area, so that the system can recognise the new module type. If an ISDN line is replacing an analogue line ensure the analogue line cable is disconnected before connecting the ISDN Line or installing the module. The same applies if an analogue line replaces an ISDN line. The Ports Modules can be removed and replaced without powering down the system The Options Module can be removed and replaced without powering down the system The Voice module can be removed and replaced without powering down the system. When a voice module is replaced all recorded messages and greetings are lost. The Internet Module can be removed and replaced without powering down the system. The Broadband Module can be removed and replaced without powering down the system. The Primary Rate ISDN Module can be removed and replaced without powering down the system. The MOH Module can be removed and replaced without powering down the system. 39
41 Installation and maintenance Manual Replacing a faulty Module MDF To replace a faulty MDF of a Ports, Internet, Broadband or Options module the procedure is as follows: 1. Remove the cabling from the MDF ensuring the cables are correctly tagged so they can be readily reinstalled. 2. Power the system down by unplugging it at the mains. 3. If a battery is installed turn off the BBU switch to disconnect the battery. 4. Remove the Module and any Network modules if appropriate. 5. Unlock the MDF module by pulling the locking bar down with a screwdriver. 6. Remove the MDF. 7. Reverse the procedure to install a new MDF. 40
42 Installation and Maintenance Manual Replacing Faulty PCBs Replacing the 008 extension board If a fault occurs on the first eight extensions the 008 extension PCB must be replaced. This PCB is NOT hot swappable. The System must be powered down to change this board ESD precautions must be taken when replacing this board. Connect to the ESD pillar on the CCU MDF before removing the CCU cover The procedure in replacing the 008 PCB is: 1. Power the system down by unplugging it at the mains. 2. If a battery is installed turn off the BBU switch to disconnect the battery. 3. Remove any voice or network modules installed. 4. Open the CCU main cover by releasing the four quarter turn screws indicated in the first diagram below. 5. Remove and replace the 008 card as indicated in the second diagram. 6. Replace the cover. 7. Replace any voice or network modules. 8. Replace the cover and power the system up. 41
43 Installation and maintenance Manual Replacing the CCU Control PCB This PCB is NOT hot swappable. The System must be powered down to change this board ESD precautions must be made when replacing this board. Connect to the ESD pillar on the CCU MDF before removing the CCU cover The procedure to be used when replacing the CCU control PCB is: 1. Power the system down by unplugging the battery at the mains. 2. If a battery is installed turn off the BBU switch to disconnect the battery. 3. Remove any voice or network modules installed. 4. Open the CCU main cover by opening the four quarter turn screws indicated in the first diagram below. 5. Remove the 008 card as indicated in the second diagram. 6. Remove the three fixing screws on the CCU control PCB as indicated. 7. Remove the power lead from the left-hand side of the CCU control PCB. 8. Slide the PCB to the left to remove it. 9. Reverse the above procedure to install a new PCB. 42
44 Installation and Maintenance Manual Power supply unit spare fuse A spare mains fuse is located in the Power supply unit. It is in a holder directly below the installed fuse (3.15A T). If there is no power being supplied to the unit check if the fuse is blown 1. Power the system down by unplugging it at the mains. 2. If a battery is installed turn off the BBU switch to disconnect the battery. 3. Remove any voice or network modules. 4. Open the CCU main cover by opening the four quarter turn screws indicated in the first diagram below. 5. Check the fuse on the Power supply 6. If it is blown replace it with the spare fuse Note: The spare fuse should only be used to replace the installed mains fuse type 3.15A T and should not be used to replace any other fuse on the power supply board. 43
45 Installation and maintenance Manual Replacing the Power Supply Unit The procedure to be used when replacing the Power Supply unit is :- 1. Power the system down by unplugging it at the mains. 2. If a battery is installed turn off the BBU switch to disconnect the battery. 3. Remove any voice or network modules. 4. Open the CCU main cover by opening the four-quarter turn screws indicated in the first diagram below. 5. Unplug the PSU cable from the CCU PCB. 6. Disconnect the mains lead. 7. Disconnect the Battery charger lead if equipped. 8. Unscrew the four retaining screws on the PSU as indicated below. 9. Remove the PSU. 10. Reverse the above procedure to install a new PCB. Spare Fuse 44
46 Replacing the CCU MDF BT Versatility Installation and Maintenance Manual This PCB is NOT hot swappable. The System must be powered down to change this board ESD precautions must be made when replacing this board. Connect to the ESD pillar on the CCU MDF before removing the CCU cover The procedure to be used when replacing the CCU MDF unit is: 1. Power the system down by unplugging it at the mains. 2. If a battery is installed turn off the BBU switch to disconnect the battery. 3. Remove any voice or network modules installed. 4. Remove the MDF Cabling making sure to tag the cabling so they can be readily reinstalled 5. Open the CCU main cover by opening the four-quarter turn screws indicated in the first diagram below. 6. Remove the 008 PCB 7. Remove the retaining screw in the MDF PCB 8. Remove the MDF PCB 9. Reverse the above procedure to install a new MDF PCB 45
47 Installation and maintenance Manual Power fail When planning the extension wiring for the system, consideration should be given to the use and location of Featurephones and 2-wire extensions. Analogue In the event of a total system power failure, at least 50% of the equipped lines are switched to extensions. Lines 1 and 2 are power-failed to extensions 26 and 27, the last two extensions on the basic unit. Line 5 is power-failed to extension 34 and Line 7 to extension 35, the last extensions on each of the expansion boards. These line positions are summarised in the table below. Note: If lines are power-failed to extension positions equipped with Featurephones, the user must replace the Featurephone with a standard 2-wire phone to answer or make calls. FEATUREPHONES CANNOT BE USED IN POWER FAIL. ISDN Line position Line 1 Extn 26 Line 2 Extn 27 Line 5 Extn 34 Line 6 Extn 35 Line 9 Extn 42 Line 10 Extn 43 Line 13 Extn 50 Line 14 Extn 51 Power-fail extension In the event of a total system failure, the ISDN lines will not operate. ISDN devices can be connected directly to the ISDN NTE or an external S bus, and work independently of the system. 46
48 Installation and Maintenance Manual Power up and test Ensure the mains plug is fitted with a 3A fuse. Switch on Power up the system by inserting the mains plug. Wait approximately 30 seconds for the system power up routine to be complete. Check that the vital activity LED is flashing. This is the top led of the four LEDs in the CCU MDF area. Check the Power led is lighting. This is the third led in the CCU MDF area Commissioning 1. Remove any anti-scratch protective film from Featurephone LCD s. 2. Label up all Featurephones and other telephones. 3. Ensure that all Featurephones provide dialling tone, ringing and hands free (loud speaking) facilities. Check that the display is not showing corrupt information. 4. Carry out a 'First Day Reset'. 5. Check that all other telephones are connected. Make sure all these phones ring and that you can dial from them. 6. Commission System 47
49 Installation and maintenance Manual Programming Essential programming is carried out either from a Featurephone connected to extension 20 or via the BT Versatility wizard, the programming PC application. Ensure that the following programming is done. Equipped exchange lines The system assumes that all line cards have lines connected to them. If lines are not connected, it is vital to unequip these lines in system programming, as follows: From the programming position, press the phone programming key select System programming. Enter the PIN and select Lines. Select Equipped lines. Equipped lines are denoted by. Unequipped lines are denoted by?. Press HANDS FREE to finish programming. Incoming ringing The phones to be rung for incoming calls are programmed as follows Select 'Lines' Select 'Incoming Ringing' Select the Line or Access Select 'Day mode', 'Night Mode' or 'Day and Night mode' Select whether the line is to ring an extension or Group. If the Line is to be presented to the Auto Attendant or Courtesy service it is selected here. Note that the first 8 extensions are in group 1 as default. To change the extensions in a group, select 'Lines' and then 'Group Programming'. First Power up reset When initiated this reset will set the system back to its factory settings. This reset can be initiated from the BT Versatility Maintenance Wizard. Commissioning Call This is carried out by the installation engineer and is programmed as follows: Select "System" Scroll through the menu and select Commission System 3 options are given on the display, "Customer ID", "Site Access No." and "Commission Call" First enter the Customer ID number and press confirm Then enter the Site Access number Once these are entered select Commission Call and press confirm. This will initiate a call into RACE where the system details are logged. Once a successful commissioning call has been made from the system, "Commission System" will be removed from the top line of the display on extension
50 Call Barring BT Versatility Installation and Maintenance Manual Extensions are entered into different Classes for barring purposes. There are 6 classes selected under 'Extension' programming. There are also four tables of codes selected in 'System' programming which determine additional codes that are barred or allowed: Select 'Extensions' Select Restriction classes Select 'Day class of service' or 'Night class of service' Select the class and enter the extensions Class 1 is no calls barred Class 2 is International calls barred. Also any additional codes added to Table 2 in Class codes programming are barred Class 3 is National and International numbers barred. Also any additional codes in Tables 2 and 3 in Class codes programming are barred. Class 5 is associated with extensions when codes entered in the 'Allowed Table in Class codes programming are to be allowed. This is combined with Classes 2 and 3 Class 6 is the additional restriction codes in the Restricted Table in Class Codes programming. These can be combined with Classes 1,2 and 3. Note: As the BT Versatility can support both ISDN and Analogue, it may be necessary to enable features for ISDN and Analogue options on the same system. 49
51 Installation and maintenance Manual 50
52 Installation and Maintenance Manual Recommendations for customer training As part of the installation, the customer is entitled to a 30 minute, system familiarisation tutorial. This should cover the following: Use of the Featurephone menus and associated keys Taking, making and transferring calls on Featurephones and two-wire phones Accessing system programming The customer may wish to use the 30 minutes to explain a selection of other features, such as: Call transferring capabilities Programming Featurephone keys Time and date programming System and /or personal speed dial programming Incoming call handling Call barring, class of service parameters Extension reset facilities Connecting modems, fax machines, EPOS machines, etc. Use of Voice module features. The features should be explained by using the BT Versatility Quick Reference User Guide and the Getting Started User Guide. Ensure the customer has a Quick Reference User Guide for each extension, one copy of the Getting Started User Guide and the CD-ROM. 51
53 Installation and maintenance Manual Troubleshooting All faults can normally be traced quite readily to a particular PCB. Prior to replacing any PCB, fault conditions should be checked to see if they are caused by programming or mis-operation. The Featurephone display will often indicate which system features have been set. System not initialising Check that all system cards have been properly installed, with all connectors fully located. No incoming calls Check that all phones programmed to ring are not programmed for DND or divert. Extension outgoing locked If you cannot get outgoing access on a 2-wire telephone, move a Featurephone to the extension. If it shows EXTN LOCK, the extension has been locked and you will need the unlock code to unlock it. No extension dial tone Check that the extension has not been disconnected through programming. Not seizing a line for outgoing calls Check if the line has been programmed for incoming calls only. Check if the line is equipped in programming. Check that the key is programmed for line access. Door intercom not operating Check the programming for the door intercom. Phone reset Remember the simple phone reset code 739, which can be dialled from any extension phone. System reset Reset: To do a warm reset of the BT Versatility press the reset button on the CCU MDF. You may also choose programming mode and choose system, reset options, and reset. Reset to default: To do a cold reset of the BT Versatility, enter programming mode and choose system, reset options, and reset to default. This will reset ALL programming to factory default. 52
54 Installation and Maintenance Manual Technical specification Type of system ISDN 2 line Analogue lines Terminals Extension capacity Featurephone capacity Standard 2-wire apparatus capacity Extension loop resistance Hybrid/PBX Max 4 ISDN (2B+D) Basic Rate lines Max 8 Loop calling Guarded clear analogue lines Max 33 V standard terminal, 40 on Hospitality system Max 32 V 8-8 key Featurephone, 40 on Hospitality system Max 32 V key Featurephone, 40 on Hospitality system Max 8 V 16 expansion console - Additional 32 programmable keys Or approved apparatus 33, 40 on Hospitality system 32, 40 on Hospitality system 33 (32 + external extension), 40 on Hospitality system 67 ohms (0.4 km) 4-wire Featurephones 336 ohms (2km) Standard Telephone 336 ohms (2 km) extension 52 only supplied on the Options Module System REN 40 Extension REN Central bell Central Bell REN Extension cabling 2 (see above for system max.) Separate port. In the Options module 2 (see above for system max) Standard 4 wire Twisted pair 0.5 mm 2 cu Central control unit (CCU) 008 Height 390 mm Maximum capacity system 8+32 CCU on Hospitality system Battery Width Depth Weight Height Width Depth Weight 12 V/7.2 AH 295 mm 160 mm 3.5 kg 390 mm 595 mm 160 mm 6.1 kg Mains supply voltage Maximum power consumption Standard 2-wire telephone signalling Standard 2-wire telephone recall signal 230 ± 10% V 50 Hz 350 VA DTMF Timed break Serial Port 8 bit, no parity, 1 stop bit speed programmable 115k2, Voic Capacities Music on hold 2 Port, 2 hours messaging capacity supporting 33 mailboxes(40 on Hospitality system), 10 Phantom Voice Boxes, 20 Group Boxes 4 Port -,4 hours messaging capacity supporting 33 mailboxes (40 on Hospitality system), 10 Phantom Voice Boxes, 20 Group Boxes 8 Port -,20 hours messaging capacity supporting 40 mailboxes, 10 Phantom Voice Boxes, 20 Group Boxes Maximum message length is defaulted at 1 minute but is programmable up to 3 minutes Internal and External calls External Music On Hold 53
55 Installation and maintenance Manual Tone on hold External Music on hold 200 ms on 200 ms off, 200 ms on 3.4 s off Stereo jack connector (on Options Module) Input impedance 10k ohm Nominal 775 mv RMS MOH Module (if no Options Module installed) Input impedance 1k6 ohm Nominal 200 mv RMS External Paging Port Output Level 25-32mA Impedance 600 ohm System speed dials Max. 500 Extension current and voltage feed Voice 36.5 volts 25 ma constant current Data 40 volts 10 ma constant current Dial tone duration Programming Remote access Ringing voltage/frequency 10 s Featurephone (default extension 20) or PC Wizard through serial port On ISDN or Analogue Lines. (Built in V32bis modem) ± 40 V 50 Hz (trapezoid) Ringing cadences Incoming call Internal call Door intercom call Call recalling 400 ms on 200 ms off, 400 ms on 2.0 s off 1 s on 2 s off 400 ms on 2.6 sec off 1s on 400 ms off, 400 ms on 1.2 s off Tone frequencies 440 Hz ±5 Hz, unless stated otherwise Tone cadences Dial Tone Continuous tone of 440 Hz ±5% and 350 Hz ±5% combined Special dial tone 800 ms on 800ms off of 440 Hz ±5% and 350 Hz ±5% combined Ringback tone Busy tone Congestion tone Hold tone Conference tone NU tone Call waiting tone 1 sec on 2 sec off 500 ms on 500 ms off 200 ms on 200 ms off 200 ms on 200 ms off, 200 ms on 3.4 s off One burst of 400 ms Continuous tone 100 ms on 4.9 s off Environmental requirements Normal working temperature 0 C to 40 C Working humidity (non-condensing) 5% to 95% Storage temperature Storage humidity -40 C to +85 C 5% to C Doorstrike relay contact Max rating 24 Volts DC 2 Amps Safety and protection EN55022, EN55024, EN60950 Door Intercom Size Height 203 mm Width Depth 73 mm 38 mm Colour of System Charcoal ref: Pantone 432C 54
56 Internet Module Info LAN 4 x 10/100 Base-Tx ports ADSL ISDN Protocols Authentication DHCP Routing Firewall Call management Management BT Versatility Installation and Maintenance Manual 10 Base-T output for an external ADSL modem Access to B-channels on PABX PPP, MLPPP, BACP IP V4 PAP/CHAP DHCP server supports up to 100 IP addresses Static routing NAT, Packet filtering Idle timers Time of day restriction Local management Remote management Installation Wizard Broadband Module Info LAN 4 x 10/100 Base-Tx ports WLAN ADSL ISDN Protocols Authentication DHCP Routing Firewall VoIP Gateway Call management Management b/g On board ADSL Modem Access to B-channels on PABX IP V4 PAP/CHAP DHCP server Static routing Stateful Inspection, Intrusion Detection, NAT, Packet filtering 2/12 Channels Idle timers Local management Remote management Browser Management Hotel Facilities Helpdesk Optional software Check in / Check out Call billing Programmable call charges Room Status Guest / Administration extensions Message waiting Alarm Calls Full remote support from a BT Maintenance Centre Remote Diagnostics Remote Programming Automatic fault reporting can be provided 55
57 Installation and maintenance Manual INDEX 20 degrees, degrees, 26 additional modules, 38 ADSL, 6, 36, 55 ADSL modem, 36 Analogue, 46 Analogue line module, 15 Analogue Line Module, 10 Analogue Lines, 33, 34 Analogue Module, 16 backplane, 12, 13 Backplane, 12 Battery, 23 Battery backup unit, 22 Cable limitations, 37 Cabling, 31 Call Barring, 49 CCU installation, 7 CCU location, 7 CCU mounting, 7 Central bell, 37 Central Bell, 6 Commissioning, 47 Connector pin- out, 32 Customer training, 56 Digital Line Module, 10 Door Intercom, 6, 33 Door Intercom connection, 30 Doorstrike, 33 doorstrike connection, 33 Electrostatic precaution (ESP), 3 Equipped exchange lines, 48 erlang, 22 Expanding, 38 Expansion, 11 Expansion module, 14 Extension connection, 31 External extension, 37 faulty Module, 40 Faulty PCBs, 41 Featurephone, 24, 25 Featurephone connections, 24, 25 Featurephone plinth, 26 Featurephone wall-mounting, 29 Hot Swapping, 34, 39 Incoming ringing, 48 Installation Checklist, 6 Internet Module, 36, 39 Introduction, 2 ISDN, 46, 55 ISDN expansion module, 17 ISDN interfaces, 33, 34 ISDN Module, 17, 18 ISDN Primary Rate interface, 33 ISDN settings, 19 Led Indicators, 23 Lightning, 3, 32, 37, 38 Long-line Extension, 6 Module, 10 Options Module, 37, 39 Ovida, 48, 55 PA (public Address), 33, 34 PC or Printer to the Serial Port, 34 Ports Module, 34 Ports Modules, 39 Power Supply Unit, 44 Power up, 47 Power-fail extensions, 46 Primary Rate Interface, 21 Primary Rate ISDN, 39 Primary Rate ISDN module, 10 Programming, 48 reset switch, 33 S 0 interface, 19 Safety, 3 Safety and precautions, 3 Spare fuse, 43 Switch on, 47 T 0 interface, 19 Technical specification, 58 Troubleshooting, 57 V 16 expansion console, 27, 28 V16, 24 V8, 25 Voice module, 39 Voice module 2 or 4 port, 10 Voic card, 20 wall bracket, 11, 12 Wiring, 31 56
58 The CE Marking on this equipment indicates Compliance with the following This device conforms to Directive 1999/5/EC on Radio Equipment and Telecommunications Terminal Equipment as adopted by the European Parliament And Of The Council Offices Worldwide The telecommunications services described in this publication are subject to availability and may be modified from time to time. Services and equipment are provided subject to British Telecommunications plc s respective standard conditions of contract. Nothing in this publication forms any part of any contract. British Telecommunications plc Registered Office: 81 Newgate Street, London EC1A 7AJ. Registered in England No: Produced by BT Business Information Systems Marketing Cover designed by H&P Graphics Limited (9966). Printed in Ireland Part No Printed on paper which meets international environmental standards
Installation and Maintenance Manual
Installation and Maintenance Manual Mitel 3000 Installation Manual 1 Contents Safety Regulations... 4 Important Safety Instructions... 4 Introduction... 6 General overview... 6 Safety Precautions during
... 10 ... 14 ... 15 ... 16 ... 17 ... 17 ... 18 ... 19 ... 19 ... 19 ... 20 ... 20 ... 20... 20 ... 20 ... 21 ... 21 ... 21 ... 21 ... 21 ...
Owner s Manual CONTENTS INTRODUCTION TO YOUR BT VERSATILITY SYSTEM...9 System description... 9 System options... 10 BT Contact Details:... 10 Using this Manual... 11 Introducing the Featurephones... 13
Get Started User Guide
GUIDE TO SYSTEM DOCUMENTATION 2 Get Started Guide 2 Phone Quick Reference Guide 2 Detailed User Manual 2 Detailed Broadband Module Manual 2 BT VERSATILITY WIZARD User Manual 2 SYSTEM DESCRIPTION 3 System
SL1100 Installation Instructions. This Installation Packet is Organized into Five Chapters:
Thank you for choosing NEC SL1100 Distributors! This Installation Packet is Organized into Five Chapters: BLUE: Hardware Installation Overview (Block Wiring, Music On-Hold, Paging, Door Box & Relays) GREEN:
Installation and Maintenance. M I T E L. www.mitel.com EMEA CALA. Global Headquarters U.S. Asia Pacific
M I T E L 3000 Installation and Maintenance. Global Headquarters U.S. EMEA CALA Asia Pacific Tel: +1(613) 592-2122 Fax: +1(613) 592-4784 Tel: +1(480) 961-9000 Fax: +1(480) 961-1370 Tel: +44(0)1291-430000
INTRODUCTION TO YOUR COMMANDER CONNECT SYSTEM...7 System description...7 System options...8 Commander Contact Details...8 USING THIS HANDBOOK...
INTRODUCTION TO YOUR COMMANDER CONNECT SYSTEM...7 System description...7 System options...8 Commander Contact Details...8 USING THIS HANDBOOK...9 INTRODUCING THE KEYSTATIONS...10 Standard Keystation...10
V-IP Featurephone Quick Reference User Guide. Introduction to your V-IP Featurephone
Introduction to your V-IP Featurephone The V-IP Featurehone provides the same functionality as the BT Versatility Featurephone. It can be connected directly to the BT Versatility system or installed at
GERONIMO ANALOGUE HEAVY DUTY TELEPHONE
GERONIMO ANALOGUE HEAVY DUTY TELEPHONE Installation and Connection Instructions K a l i k a L t d., I n n o v a t i o n H o u s e, A l e x a n d e r B e l l C e n t r e, H o p k i n s o n Wa y, A n d o
XN120 Getting Started Guide Rev 1.2 (March 2005) 991409-5
This guide explains the installation, configuration and operation of the XN120 Telephone System including the exchange line and telephone connections. Further information will be supplied with any optional
Welcome to BT Inspiration An introduction to your new BT Inspiration System and its documentation 6 Featurephone basics 7
Contents PAGE Welcome to BT Inspiration An introduction to your new BT Inspiration System and its documentation 6 Featurephone basics 7 Your BT Inspiration Featurephone 7 Facility menus and scroll keys
eircom advantage 4800 System Introduction
eircom advantage 4800 System Introduction Specifications subject to change without notice. Facilities described may or may not be supported by your network. eircom advantage is the registered trademark
Table of Contents. Mitel 3000 Getting Started Guide
Get Started Guide Table of Contents GUIDE TO SYSTEM DOCUMENTATION...1...1 Phone Quick Reference Guide...1 Administrator s Manual...1 Broadband Module Manual...1 IP Phone Quick Reference Guide...1 Documentation
InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9580-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
InnoMedia ESBC 9380-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9380-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
PBX System. Installation Manual AS 200 IT
PBX System Installation Manual AS 200 IT Safety Notes - Installation and Maintenance of the System only by trained personnel. - Important! To prevent personal injury and damage to equipment please ensure
Inter-Tel 3000 Basic Technical Training Self-Study Course
Inter-Tel 3000 Basic Technical Training Self-Study Course Inter-Tel, Inc. 2007 All rights reserved. Table of Contents ABOUT THIS COURSE...1 Taking the Course...1 Taking the Exam...1 OVERVIEW OF INTER-TEL
Inter-Tel. 3000 IP Phone Quick Reference Guide
Inter-Tel 3000 IP Phone Quick Reference Guide Introduction to your IP Phone The Inter-Tel 3000 IP Phone provides the same functionality as the Inter-Tel 3000 digital telephone sets. It can be connected
Introducing Your Cisco IP Phone
CHAPTER 1 A Cisco IP Phone is a full-feature telephone that provides voice communication over the same data network that your computer uses. This phone functions much like a traditional analog phone, allowing
2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting
USER S MANUAL Part 2 2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting Please also read Part 1 Important Product Information AT&T and the globe symbol are registered
Setting Up the Cisco IP Phone
CHAPTER 3 This chapter includes this following topics, which help you install the Cisco IP Phone on an IP telephony network: Before You Begin, page 3-1 Installing the Cisco IP Phone, page 3-6 Adjusting
Quick Start Guide to Your IP Phone
Quick Start Guide to Your IP Phone SPA 300 Series IP Phone Models SPA 301 and SPA 303 SPA 300 Series IP phone Phone stand RJ-45 Ethernet cable Quick start guide Product CD-ROM Welcome Thank you for choosing
Setting Up the Cisco Unified IP Phone
CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phone on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone 7962G
emta (VoIP over Cable Modem)
emta (VoIP over Cable Modem) User Manual Version 1.0 Important Rules for Safe Operation Safe Use of Equipment Read all the instructions before operating this equipment with particular emphasis to safety
Getting Started. Table of Contents. Hybrid IP-PBX
Hybrid IP-PBX Getting Started Model no. KX-TDA30 Table of Contents 1 Before Installation... 2 2 Installation... 4 3 Starting the Hybrid IP-PBX... 11 4 Customising the Hybrid IP-PBX... 14 5 Confirming the
User Guide BT CONVERSE 425
User Guide BT CONVERSE 425 This product is intended for connection to analogue public switched telephone networks and private switchboards in the United Kingdom. Please open this page for an At a glance
Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA
Quick Start Guide Cisco SPA232D Mobility Enhanced ATA Package Contents Analog Telephone Adapter Ethernet Cable Phone Cable Power Adapter Quick Start Guide Product CD-ROM Welcome Thank you for choosing
BT Big Button 100. User Guide
BT Big Button 100 User Guide Welcome to your BT Big Button 100 phone Large buttons for easy dialling. Handsfree make and receive calls using the loudspeaker. One-touch 1571 button dials your network answering
P-2024. Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address http://192.168.5.1 Password 1234. Version 3.60 7/2007 Edition 1
P-2024 VoIP Analog Telephone Adaptor Quick Start Guide Version 3.60 7/2007 Edition 1 DEFAULT LOGIN IP Address http://192.168.5.1 Password 1234 Copyright 2007. All rights reserved. Overview Use your P-2024
User Guide for Cisco Unified IP Phones 7961G and 7941G
User Guide for Cisco Unified IP Phones 7961G and 7941G Common Phone Tasks Softkey Definitions View online help on the phone Press. Place a call Redial a number Switch to the handset during a call Switch
General notes: To avoid problems, always use:
Questions and answers If you have any questions about the use of your phone, you can contact us at www.gigaset.com/service at any time. For more information about combining different Gigaset devices, visit:
IP Office Installation Manual
IP Office Installation Manual Page 2 - Contents Contents Introduction...5 General...5 Scope of Manual...5 IP401 Compact Office Platform...5 General...6 IP401 Compact Office - Front View...7 Port connections...
5330 IP Phone Quick Reference User Guide
5330 IP Phone Quick Reference User Guide Introduction to your Mitel 5330 IP Phone The Mitel 5330 IP Phone provides the similar functionality as the Mitel 3000 Feature Phone. It can be connected directly
Setting Up the Cisco Unified IP Phones
CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phones on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone
MITEL. 3000 communications system
MITEL 3000 communications system The Scalable, Voice-centric Communications Platform for Business Today s diverse environments require advanced communications technology to address new and dynamic ways
FORUM 100 PBX 1/8 with CLIP & CNIP USER MANUAL
FORUM 100 PBX 1/8 with CLIP & CNIP USER MANUAL Dear Customer, Thank you for choosing the FORUM TM 100 PBX, a system designed for both the home and the office. The FORUM TM 100 manages 1 external and 8
Features of Your Cisco Unified IP Phone
Cisco Unified IP Phone 8961, page 1 Cisco Unified IP Phone 9951, page 9 Cisco Unified IP Phone 9971, page 18 General Phone Information, page 27 Cisco Unified IP Phone 8961 The following sections describe
OPERATING INSTRUCTIONS
Gemini Speakerphone OPERATING INSTRUCTIONS This Interquartz telephone has been manufactured to very high standards and is very easy to use. Please read this manual carefully to find out how to use the
CONNECTING YOUR BUSINESS WITH TOMORROW KX-TD
CONNECTING YOUR BUSINESS WITH TOMORROW KX-TD Digital business telephone system range KX-TD range Digital super hybrid systems For today The Panasonic brand has been built upon years of manufacturing top
EncoreCX. The Ideal Communications Solution for BUSINESS and RESIDENTIAL Applications
EncoreCX The Ideal Communications Solution for BUSINESS and RESIDENTIAL Applications The Scalable, Voice-Centric Communications Platform for BUSINESS and RESIDENTIAL Applications Whether you are at work
Edition 4 26 March 97. Response 130 telephone and answering machine. User guide
Edition 4 26 March 97 Response 130 telephone and answering machine User guide At a glance Directory label For making a note of numbers stored in the memories. One-touch dial memory buttons Allows you to
CONNECTING YOUR BUSINESS WITH TOMORROW KX-TD. Digital business telephone system range
CONNECTING YOUR BUSINESS WITH TOMORROW KX-TD Digital business telephone system range KX-TD range Digital super hybrid systems For today The Panasonic brand has been built upon years of manufacturing top
Welcome to life on. Get started with this easy Self-Installation Guide.
Welcome to life on Get started with this easy Self-Installation Guide. Welcome to a network that s light years ahead. Welcome to life on FiOS. Congratulations on choosing Verizon FiOS! You re just a few
Innovative DOOR STATION Solutions
Innovative DOOR STATION Solutions When a visitor arrives at your front door or gate we ring... Your mobile when you are out Your normal telephones in your home Your PABX system in your office Communicating
ECR Shelf System Installation Guide Centralized Rack Mount Call Recording
Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: [email protected] [email protected] www.algosolutions.com
Enterprise Telephone. Model 98390 OPERATING INSTRUCTIONS
Enterprise Telephone Model 98390 OPERATING INSTRUCTIONS This Interquartz telephone has been manufactured to very high standards and is very easy to use. Please read this manual carefully to find out how
Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice
Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is
How To Use An Ip Phone On A Cell Phone On An Ipphone On A Sim Sim Sim (Cisco) Or Ip Phone (Ip Phone) On A Iphone Or Ipphone (Ipphone) On An Iphon Or Ip
USER GUIDE Cisco Small Business SPA 300 Series IP Phones Models 301 and 303 Contents Chapter 1: Getting Started 6 About This Document 6 Overview of the Cisco Small Business 300 Series IP Phones 8 Caring
Personal Assistance System Owner's Guide
Owner's Guide PSC07 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,
Model PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display 6 - Setting Date
AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974
974QSG_(Rev14)ml_23.5.06 5/23/06 11:28 AM Page 1 QUICK START GUIDE AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974 This Quick Start Guide provides basic instructions.
DVG-2101SP VoIP Telephone Adapter
This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DVG-2101SP VoIP Telephone Adapter Before You Begin 1. If you purchased this VoIP Telephone
Quick start guide to your IP phone
Quick start guide to your IP phone IP Phone Models SPA501G, SPA502G, SPA504G, SPA508G, and SPA509G Welcome Thank you for choosing the Cisco Small Business IP Phone. This guide describes how to install
OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT
OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT Welcome to Verizon Wireless Thank you for choosing Verizon Wireless Home Phone Connect. You re now connected to the power of America s most reliable
KX-TD connection diagram
KX-TD connection diagram Application Software Ask for a brochure and/or quotation PanaStat (Call Management Software) Desktop Telephony Assistant (3rd Party CTI solution) Integrated Headsets Optional Features:
USER GUIDE. Cisco Small Business Pro. SPA 504G IP Phone for 8x8 Virtual Office
USER GUIDE Cisco Small Business Pro SPA 504G IP Phone for 8x8 Virtual Office Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing
DIGITAL+FUTURE+DIGITAL+FUTURE+DIGITAL+FUTURE+DIGITAL+FUTURE+DIGITAL+FUTURE
aria 50, 130, 300 & 600 Digital Business Communications Solutions DIGITAL+FUTURE+DIGITAL+FUTURE+DIGITAL+FUTURE+DIGITAL+FUTURE+DIGITAL+FUTURE Affordable, Reliable and ready for the Future. aria 50, 130,
ABOUT YOUR BT QUANTUM SYSTEM...
Contents CONTENTS... 2 USING THIS DOCUMENT... 1 BT CONTACT DETAILS... 1 ABOUT YOUR BT QUANTUM SYSTEM... 2 BT QUANTUM HARDWARE... 2 Digital Base Module... 3 IP Base Module... 3 Telephony Expansion Module
UK s best selling phone brand. User Guide. BT Big Button 200 Corded Phone
UK s best selling phone brand User Guide BT Big Button 200 Corded Phone 2 Welcome. to your BT Big Button 200 telephone Large buttons for easy, accurate and more comfortable dialling Large display to assist
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH
TALKSWITCH QUICK GUIDE CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH CONNECTING PHONES, FAXES & DEVICES TO TALKSWITCH CT.TS005.504.EN - 03 TalkSwitch Back Panel TalkSwitch 48-CA/ 48-CVA shown here. Model
Converse 320. Userfriendly Guide
Converse 0 Userfriendly Guide Return Diversion Minder On Off At a glance IMPORTANT Next Inserts a space in a number when storing numbers in the memory. Clear Used to edit numbers when pre-dialling or when
AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974
974CIB_(Rev11-12)ml24.05.06 5/24/06 9:29 PM Page II USER S MANUAL Part 2 AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974 For Customer Service Or Product Information,
FAQs. XAP Frequently Asked Questions. Software/Configuration
XAP Frequently Asked Questions ~ Software/Configuration ~ Echo Cancellation ~ Audio Performance ~ Expansion Bus ~ Firmware ~ Installation ~ Presets ~ Telephone Hybrid Software/Configuration What is the
Quick Reference Guide
Welcome to BT Business Total Broadband Quick Reference Guide Read the information in this Quick Reference Guide to help you start using your new BT Business Total Broadband service powered by fibre. The
Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
Four-Line Small Business System Speakerphone 945
945QSG_(rev22)ml23.5.06 5/23/06 11:29 AM Page 1 QUICK START GUIDE Four-Line Small Business System Speakerphone 945 This Quick Start Guide provides basic instructions. For additional installation options
Quick Start Guide. Cisco SPA100 Series Analog Telephone Adapters. SPA112 Two Port Phone Adapter SPA122 ATA with Router
Quick Start Guide Cisco SPA100 Series Analog Telephone Adapters SPA112 Two Port Phone Adapter SPA122 ATA with Router Package Contents Analog Telephone Adapter Ethernet Cable Power Adapter Quick Start Guide
FortiVoice. Version 7.00 Start Guide
FortiVoice Version 7.00 Start Guide FortiVoice Version 7.00 Start Guide Revision 2 18 October 2011 Copyright 2011 Fortinet, Inc. All rights reserved. Contents and terms are subject to change by Fortinet
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Installation Guide for Hive Active Heating
Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during
Model SPA 303G Quick Start Guide
mydatavo Model SPA 303G Quick Start Guide Welcome Thank you for choosing Datavo as your business solutions provider. This guide describes how to install your phone and how to perform some basic tasks.
Four-Line Small Business System Speakerphone 945
945 CIB 2ATT 3/14/05 9:58 AM Page III USER S MANUAL Part 2 Four-Line Small Business System Speakerphone 945 Please also read Part 1 Important Product Information 2005 Advanced American Telephones. All
Ipiphony Phone System. User Manual. 1 P a g e
Ipiphony Phone System User Manual 1 P a g e About this Guide This guide explains how to use the basic features of your new Aastra phones. Not all features listed are available by default. Contact your
USER GUIDE. Cisco Small Business. SPA 303 IP Phone for 8x8 Virtual Office
USER GUIDE Cisco Small Business SPA 303 IP Phone for 8x8 Virtual Office May 2011 Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Ericsson W25. Mobile Networks. Quick Installation Guide
Ericsson W25 Fixed Wireless Terminal for WCDMA/HSDPA Mobile Networks Quick Installation Guide Table of Contents INTRODUCTION... 3 Package Contents... 3 Requirements... 3 INSTALLATION... 4 Unit Preparation...
Analogue Telephone User Guide
Analogue Telephone User Guide IP COMMUNICATIONS PLATFORM FOR THE SMALL BUSINESS Specifications subject to change without notice. Facilities described may or may not be supported by your network. This documentation
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
USER GUIDE Cisco Small Business
USER GUIDE Cisco Small Business Cisco Unified Communications Manager Express for IP Phone Models 30X August 2013 Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Digital Phone Installation & User Guide
Digital Phone Installation & User Guide Telephone #1 Voicemail PIN Telephone #2 Voicemail PIN skybeam high speed internet digital phone We would like you to verify that the 911 address we have for you
How To Use An Ip Phone On A Cell Phone On An Ip Cell Phone
USER GUIDE Cisco Small Business Cisco SPA50X and SPA51X SIP IP Phones Models SPA501G, SPA502G, SPA504G, SPA508G, SPA509G, SPA512G, and SPA514G Contents Chapter 1: Getting Started 6 About This Document
Model PBX 416 Plus System Administration Guide
Model PBX 416 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 - Entering password in Direct 5 Dial Mode Exchange Line
Welcome. Digital Phone. Digital Phone. Digital Phone
Welcome to Welcome to Wi-Power Service Thank you for choosing Wi-Power Internet and Services! This booklet includes important information to better acquaint yourself with Wi- Power Service. Features: Wi-Power
Four-Line Intercom Speakerphone 944
1 USER S MANUAL Part 2 Four-Line Intercom Speakerphone 944 Please also read Part 1 Important Product Information AT&T and the globe symbol are registered trademarks of AT&T Corp. licensed to Advanced American
AT&T Small Business System Speakerphone with Digital Answering System and Caller ID Call Waiting 984
USER S MANUAL Part 2 AT&T Small Business System Speakerphone with Digital Answering System and Caller ID Call Waiting 984 Please also read Part 1 Important Product Information 2004 Advanced American Telephones.
Linksys Voice over IP Products Guide: SIP CPE for Massive Scale Deployment
Linksys Voice over IP Products Guide: SIP CPE for Massive Scale Deployment Corporate Headquarters Linksys 121 Theory Drive Irvine, CA 92617 USA http://www.linksys.com Tel: 949 823-1200 800 546-5797) Fax:
Model PBX 416+ Programming & User Guide
Model PBX 416+ Programming & User Guide 1 Introduction... 5 Installation hints... 5 Wall mounting... 5 System programming... 6 System password... 6 Changing the password... 6 Exchange line set up... 6
Parrot MKi9000. User guide
Parrot MKi9000 User guide Contents Contents... 2 Installation... 3 Before you begin... 3 Checking the car configuration... 3 Caution... 3 Removing the car stereo... 3 Installing the kit... 4 Car stereo
Cisco Unified IP Phone 8961, 9951, and 9971 User Guide for Cisco Unified Communications Manager 8.0 (SIP)
Cisco Unified IP Phone 8961, 9951, and 9971 User Guide for Cisco Unified Communications Manager 8.0 (SIP) Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com
SAGEM F@st TM 1201/1241 V2
SAGEM F@st TM 1201/1241 V2 Quick Installation Guide 253156400-A_GIR 1201 V2 STD-gb.i1 1 14/10/2008 16:59:35 Contents 1 contents of the pack...2 2 connecting YOUR MODEM...3 2.1 Connecting your router...3
USER GUIDE Cisco Small Business
USER GUIDE Cisco Small Business Cisco SPA50X and SPA51X SIP IP Phones Models SPA501G, SPA502G, SPA504G, SPA508G, SPA509G, SPA512G, and SPA514G Contents Chapter 1: Getting Started 6 About This Document
User s manual. ML17929 Two-line corded telephone with caller ID/call waiting
User s manual ML17929 Two-line corded telephone with caller ID/call waiting Congratulations on purchasing your new AT&T product. Before using this AT&T product, please read Important safety information
System Administration Guide. Model KS 832. Expandable up to 1664
System Administration Guide Model KS 832 Expandable up to 1664 Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display
VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book
VoCALL - CFVCM/CFVCWM & CFVCX8 Fire Telephone & Disabled Refuge Network System User Manual & Log Book VoCALL Fire Telephone & Disabled Refuge Network System Introduction A VoCALL Emergency Voice Communications
USER GUIDE Cisco Small Business
USER GUIDE Cisco Small Business IP Phone Models SPA50X (SPCP) Contents Chapter 1: Getting Started 4 About This Document 4 Overview of the Cisco Small Business IP Phones 6 Caring for Your Phone 7 Understanding
Dialog 4220 Lite/Dialog 4222 Office
Dialog 4220 Lite/Dialog 4222 Office System telephones for MD110 Communication System User Guide Flinders University Table of Contents Description 2 Incoming Calls... 10 Outgoing Calls... 12 During Calls
UK s best selling phone brand. User Guide. BT Decor 2200 Corded Phone
UK s best selling phone brand User Guide BT Decor 2200 Corded Phone 2 This User Guide provides you with all the information you need to get the most from your phone. Before you make your first call you
