REHABILITATION STANDARDS MANUAL
|
|
|
- Harold Atkins
- 10 years ago
- Views:
Transcription
1 REHABILITATION STANDARDS MANUAL
2 Specifications and Numbers Instructions to Bidders Instructions to Bidders 1-4 Concrete - General Specifications 1. Pier Foundations 5 2. Continuous Footing 5 3. Concrete Slab 5 4. Concrete Block Walls 6 5. Crawl Space Ventilation 6 6. Exterior Steps 6 7. Concrete Drives 6 8. In conflict with 6 Carpentry General Specifications 8. Floor Framing 7 9. Floor Repair Exterior Flooring Wall Framing New Stud Wall Closets Clothes Closets Linen Closets Heat Unit Scuttle Hole Roof Framing 8 Roofing General Specifications 18. Built Up Roofing Shingle Roofing Mineral Surface Roofing Rubberoid Granulated Roofing Roof Ventilation Lead Boots for Vent Pipes 10
3 Windows General Specifications 24. Window Window Repair New Window Screens Window Screens Rescreening 11 Doors General Specifications 28. Door Repair New Interior Doors New Bi-Fold Doors New Exterior Doors Sliding Glass Doors Aluminum Screen Doors Wood Screen Doors 12 Exterior General Specifications 35. Exterior Siding Clapboard, Bevel or Drop Exterior Siding T Exterior Siding Vinyl Exterior Finish Stucco Soffit and Fascia Aluminum and/or Vinyl Fascia Repair Soffit Replacement or Repair (Wood) Leaders and Gutters 13 Insulation General Specifications 43. Insulation 14
4 Ceiling & Wall General Specifications 44. Ceiling Finish Drywall Drop Ceiling Drywall Ceiling Finish Popcorn Ceiling Finish Knock-Down Ceiling and Wall Finish Veneer Plaster Ceiling and Wall Finish Drywall Wall Finish Drywall Wall Finish Knock-Down Wall and Ceiling Finish ¼ Drywall Wall Finish Paneling 15 Painting General Specifications 54. Painting 15 Cabinets - General Specifications 55. Cabinets Medicine Cabinets Vanity Cabinets Base Cabinets Wall Counter Tops 15 Bathroom General Specifications 60. Wall Finish - Ceramic Tile Ceramic Fixture Set Grab Bars 16 Flooring General Specifications 63. Flooring Underlayment Floor Covering Tile Floor Covering Sheet Vinyl Floor Covering Carpet Base Trim 16
5 Appliances General Specifications 68. Appliances Range Hoods 17 Systems General Specifications 70. Mechanical Equipment Repair Heating Electrical Plumbing 18 Pest Extermination General Specifications 74. Pest Extermination 20 Construction Debris General Specifications 75. Construction Debris 20 A.D.A. Requirements This section is to be used only as a guide for estimating jobs. The actual A.D.A. Code shall be used for all specifications Lead-Based Paint Maintenance Planning Tool This Lead-Based Paint Maintenance Planning Tool is a guide designed for you to develop a custom fit checklist to conduct lead-based paint maintenance activities in a safe manner APPENDIX P - PAINTING WORK TYPE SYMBOLS C= Painting D= Demolition R= Repair N= Replace with New P= Provide with New
6 INSTRUCTIONS TO BIDDERS A. INSPECTION OF SITE Each bidder should visit the job site and fully familiarize him/herself with the conditions and all labor and materials required. The bidder should fully familiarize him/herself with the facilities available and the difficulties and restrictions pertaining to the performance of the contract. The bidder should thoroughly examine and familiarize him/herself with the drawings, technical specifications and all other contract documents. The contractor, by execution of the contract, shall in no way be relieved of any obligations under it due to his/her failure to receive or examine any form or legal instrument, or failure to examine the site and consider all existing conditions. The City of Ocala will be justified in rejecting any protest based on facts pertaining to all conditions, which he/she should have examined prior to the initial bid submittal. B. REQUEST FOR PAYMENT Each request for payment invoice must be submitted in writing, on company letterhead. It should list the work completed line by line with associated cost and be signed by the contractor. Each invoice must be submitted with a completed request for payment form (available from the Community Development Office) two weeks prior. To process a check for any given Friday, the invoice and request for payment form must be received by the Community Development Office two weeks prior. City checks are generally issued every Friday. No requests for payment will be processed before final inspection by the building department has been performed and approved for that work. C. CHANGE ORDERS AND WORK ITEMS EXCHANGE REQUEST FORM Each change order request must be in writing, on company letterhead, and signed by the contractor. All change orders must be approved by the rehab specialist prior to field implementation. To request payment for a change order, it must be submitted prior to the completion of the job. A work item exchange request form must be filled out if any work items are going to be exchanged. The form requires the signature of the contractor and the Rehabilitation Specialist prior to initiating any work exchanges. D. CITY OF OCALA BUILDING DEPARTMENT PERMITS AND INSPECTIONS Each rehabilitation job shall have the required permits (IE: building permit, plumbing permit, electrical permit and H.A.R.V. permit). The contractor is responsible for purchasing the building permit and insuring that his/her sub-contractors purchase their required permits. All electrical, plumbing, mechanical, and structural inspections must be made by the City of Ocala Building Department. The contractor is required to notify the Building Department for each of the required inspections. When calling the Building Department (352) , for an inspection, you will need the address, owners name, contractor (on plumbing and electrical inspections, the plumber or electrician is the contractor) and the permit number. 1
7 E. COMMUNITY DEVELOPMENT INSPECTION When opening a roof for repair and/or replacement of roof framing, bracing or sheathing an inspection is required prior to drying in the roof. Additional structural inspections may be required during the rehabilitation project. Any framing members exposed during the rehab project such as framing studs, ceiling joist, floor joist, rafters, sheathing and etc. are to be inspected / approved by the Rehabilitation Specialist prior to closing. All exterior plywood and framing lumber must be labeled exterior grade and seen by the Rehabilitation Specialist. F. REHABILITATION SPECIFICATIONS These specifications are intended to be used with a work write up sheet. Specific items on these sheets intended to be used for bidding will be referred to on the work write up sheet. The phrase or equal shall be interpreted to mean equal in quality and integral properties and similar in design and will be required to be approved by the rehab specialist prior to use.. All materials and workmanship shall comply with applicable codes and requirements of the Florida Building Code. All necessary permits as determined by the City Building Department are to be purchased and properly displayed on the job site. The general contractor is responsible for all general specifications concrete, carpentry and roofing when applicable, as well as the specification number specified in the work write up. G. MATERIAL AND PRODUCTS OBJECTIVE To provide materials of such kind and quality as to assure that the dwelling will provide: a. Appropriate structural strength b. Adequate resistance to weather and moisture c. Reasonable durability and economy of maintenance QUALITY OF MATERIALS AND PRODUCTS All materials and products used as replacement or additions in rehabilitation construction shall be of good quality conforming to general accepted good practice. The suitability of special materials and products, not conforming to national standards, shall be determined by the City of Ocala s Community Development Rehabilitation Specialist after an evaluation of its properties and performance characteristics. STANDARDS FOR MATERIALS AND PRODUCTS For specific requirements of new materials and products used as a replacement or addition to a dwelling being rehabilitated, reference shall be made to the Florida Building Codes and the standards of the American Society for Testing Materials. 2
8 QUALITY SPECIFICATIONS 1. Scope of work shall include all labor, materials, equipment, permits, drawings (if any) and services necessary for the proper completion of the rehabilitation specified in the work write up. 2. The work write up shall take precedence over this standard specification; and when in conflict, the material, equipment and workmanship called for in the work write up shall be required. 3. The drawings of the floor plan, if any, are diagrammatic only, illustrating the general intention of the Rehabilitation Specialist; they do not show all of the work required, exact dimensions, or construction details. 4. Workmanship shall be done in accordance with the standards, which the trades know as a workman-like manner. No work will be accepted that does not conform with the standard of a workman-like manner. All work shall be done in accordance with the standards of all trades and this work is to be done in a workman-like manner. 5. Repairs shall be made to all surfaces damaged by the contractor resulting from his work under this contract at no additional cost to the owner or the City of Ocala. 6. Applicable laws and regulations of Federal, State and City of Ocala code of ordinances shall be complied with in case of conflict, the most stringent shall apply. 7. Quantities and locations will be indicated in the bid specifications sheets. 8. No substitutions for any items listed in the specifications will be accepted unless approved in writing by the Rehabilitation Specialist. 9. When rehabilitation work is in progress, the general contractor will not be paid for any work deviating from the work write up specifications unless approved through the construction change order procedures, with written consent of the Rehab specialist. 3
9 10. The general contractor shall be held responsible for the execution of this work in accordance with the true intent of the drawings, write up, or specifications. Contractor is to complete a first class job and furnish all labor and materials required whether or not each and every method is specifically mentioned. 11. All materials furnished shall be new and without any indication of damage or breakage. If usually packaged, the material shall be brought to the job in original unbroken containers. 12. Brand names mentioned together with phrase or equal indicates that other makes of equal quality and suitability may be used. The Rehabilitation Specialist reserves the sole right to decide equality of materials. 13. Materials and conditions not specified, shall be the best adapted for the purpose. 14. Installation of any materials or products shall be in accordance with the manufacturer s directions and specifications. 15. The general contractor shall be responsible for damage due to negligence to all existing floor covering, walls, ceiling, appliances, household goods, and items such as shrubs throughout construction. 16. During construction all debris shall be contained in an on-site trash container or dumpster which will be provided by the contractor. 4
10 Concrete General Specifications These general specifications are mandatory where applicable. A. No concrete is to be placed over grass, roots or foreign materials. B. All reinforcing bars shall be free of scale, rust or coating that will reduce concrete bond. C. All reinforcing bars shall be sized as designated by the Florida Building Code. D. All concrete slabs shall be separated from existing construction by a ¼ asphalt impregnated expansion joint material. Additional expansion joints shall be installed as otherwise designated by the FBC and in the work write up. E. Fill dirt shall be clean, compacted and free of deleterious material. F. All materials used for concrete forms shall be removed after concrete has set. Voids in exposed concrete surfaces shall be filled with compatible non-aggregated cement material and finished smooth. G. Installment of all foundations, slabs and footings will also conform with the standard for hurricane resistant residential construction code. 1. Pier Foundations Minimums Piers shall be solid one-piece, reinforced concrete (2,500 P.S.I.) minimum dimension 8 x 8 x 16 C.M.U. according to the Florida Building Code. Height equal to the distance from the bottom of the joist or sill to the existing ground surface. All piers are to be 8 on center with galvanized metal termite shields, unless otherwise designated in the work write up. Pads shall be 24 x 24 x 8 poured 12 below finished grade with 3 #5 pieces of re-bar each way. One #5 bar is to be tied to the bottom steel and extend within 3 of the top of pier. Pads shall be poured using 2,500 P.S.I. concrete. All connections from pier to joists must be set in the concrete. Connectors used must be appropriate for the application when leveling is necessary all jacking and leveling shall be done before installing new piers, spacers are not acceptable. 2. Continuous Footing All continuous footings shall be 16 wide x 8 deep extending at least 12 below the finished grade, reinforced with two #5 re-bar, lapped 25 at each splice. Poured concrete shall be 2,500 P.S.I. Re-bar shall have a minimum concrete coverage of 3 from both the bottom and side of the footing. No concrete shall be poured over grass, roots, or debris. 3. Concrete Slab All concrete slabs will be a minimum 4 thick using 6 x6 NO. 10/10 wire mesh poured with 2,500 P.S.I. concrete. No concrete shall be poured over grass, roots, or debris. Soil shall be pre-treated per requirements of the Florida Building Code. 5
11 4. Concrete Block Walls Minimums Exterior block walls shall be constructed on a 10 x16 continuous footing. 8 x8 x16 masonry blocks shall be used with the correct mortar mix for the application. Top course shall be a lintel block with two #5 re-bar lapped 25 at all splices and poured solid using 2,500 P.S.I. concrete. 5. Crawl Space Ventilation Provide cross ventilation for crawl space under wood floor systems. Opening area shall comply with the Florida Building Code, with wire mesh sized according to the same. 6. Exterior Steps Minimum tread size shall be no less than 10 wide. Maximum riser height is 7 3/4 on all exterior steps. All stairs with three or more risers above grade or floor level shall be equipped with a handrail as required by the Florida Building Code. a. Pre-Cast Steps shall be standard size placed over a min. 4 concrete slab. b. Hollow Poured Steps shall be formed and poured over 8 x16 footing. Wall thickness shall be a minimum of 4. c. Wood Framed Steps shall be pressure treated 2 x12 stringers shall terminate at slab on grade. Slab Dimensions shall be the width of the stringers and shall extend from the heel of the stringers three feet past the toe to form a landing. d. Platform at top of steps shall be 3 x 3 minimum. 7. Concrete Driveway Minimums 4 thick concrete 10 wide. Concrete shall be 2,500 P.S.I. Apron shall be 6 thick with 6 x6 # 10/10 wire mesh. Sidewalks shall be 6 thick at driveway. All concrete shall be broom finished. H. In the event of any conflict with the above minimum standards, provisions of the Florida Building Code shall take precedence. 6
12 Carpentry General Specifications Carpentry general specifications shall be governed by the more stringent of the Florida Building Code and the following: a. All wood or lumber in contact with concrete, earth or within 12 of grade soil shall be pressure treated. b. Furring strips applied to masonry shall be 1 x 2 pressure treated No. 2 yellow pine or equal. c. All structural timbers shall be pressure treated No. 2 yellow pine or equal, U.N.O. d. Exterior exposed woodwork shall be pressure treated lumber. e. All studs shall be stud grade quality or equal. f. Interior woodwork and trim shall be ponderosa pine, or clear shop grade pine, or equal. Base trim shall have mitered outside corners, inside corners can be mitered or coped. g. All studs shall be 16 on center. All load bearing stud walls shall have double top plates with staggered joints. Hurricane clips shall be installed using Simpson strong tie or equal in quality. h. All new and modified construction will conform to the Florida Building Code and the standard for hurricane resistant residential construction. 8. Floor Framing All new or replaced floor joists shall be no. 2 southern yellow pine, minimum size per code. Floor joists shall be supported at their extreme ends by either a 2 x2 ledger board or appropriate joist hanger. Joists must be continuous without splices. 9. Floor Repair All damaged, loose or broken sub flooring shall be repaired or replaced before the installation of a finished floor. All end joints should occur over joists. Adjacent end joints shall be staggered. Replaced flooring shall match existing in size quality and finish unless being covered by vinyl, tile, or carpet in which case exterior grade plywood of the same thickness can be used. 10. Exterior Flooring Tongue and groove flooring shall be 1 x4 grade C when used on porches or enclosed utility rooms. Splicing and staggering of joints shall be the same as noted in #9. Floor Repair. 7
13 11. Wall Framing Install exterior plywood or O.S.B. sheathing or diagonally brace with 1 x4 at a 45 degree angle on both sides of new corner posts. New studs in existing or new walls shall be spaced 16 on center. All load bearing stud walls shall have a double top plate with staggered joints. All headers over door and window openings shall be doubled. Appropriate connectors shall be used for all framing per the Florida Building Code. 12. New Stud Walls Studs shall be 2 x4, 16 on center. Sole plates shall be pressure treated when being installed on concrete slabs. Anchor bolt size and spacing along with washer and bolt size shall conform to the current Florida Building Code. 13. Closet - Clothes Clothes closets shall be framed using 2 x4 studs, 16 on center. Inside dimensions shall be 2 deep and 4 wide unless specified differently in the work write up. Closets shall be finished inside and out with ½ drywall, base trim, pre-hung hollow core doors or bi-fold doors, clothes shelf and rod. Wire shelving can be used substituting wood shelf and rod. 14. Closet Linen Linen closets shall be framed with 2 x4 wood studs 16 on center. Inside dimensions shall be 2 x 2 6. Closet shall be finished inside and out with ½ drywall, base trim, prehung hollow core door or bi-fold door, and five shelves. Shelves can be wood or wire. 15. Closet Heat Unit Heat unit closet shall be sized to accommodate the heat unit being installed. Closet shall be finished inside with ½ drywall, base trim, pre-hung hollow core door or bi-fold door. 16. Scuttle Hole Scuttle holes shall be 22 x36 rough opening, trimmed to match existing trim with drywall lid finished to match ceiling finish. 17. Roof Framing Replace all damaged or deteriorated rafters. When rafter tails are to be replaced, cut them back flush with the exterior siding unless the deteriorated section can be cut off and new wood can be spliced to the good material. New rafter tails shall be the same dimension as the old, attached to the existing rafter by toe nailing and attached to the roof sheathing by nailing through the sheathing to the rafter tail. Sistering tails is also acceptable by extending new material 18 to 24 from the face of the exterior wall into the rake of the existing rafter. All rafters are to be attached to wall framing with the proper connector for the application and uplift. Collar ties shall be installed on all new rafters or as designated on work write-up for existing rafters. Ties shall be 1 x6 pine or fir and located in the upper third of the rafter. All angle cut on ties shall be closely fitted to the underside of the sheathing. 8
14 When a ridge board is to be installed its minimum thickness shall be 1 and not less in depth than the cut end of the rafter it joins. Ceiling joists and rafters shall be nailed to each other where the two are in contact. Ceiling joists shall be continuous or can be spliced over a load bearing wall to provide a continuous tie across the structure. O.S.B. Roof Sheathing shall be minimum of 4 x8 x1/2 with spacer clips between sheathing. Solid sheathing for repairs shall be the same size as the existing sheathing. Sheathing supporting barge rafters shall extend a minimum of two trusses or rafters or a minimum of 4. 9
15 Roofing General Specifications All roofing shall be applied in conformance with the Florida Building Code. All vents, stacks and chimneys projecting through the roof shall have lead or metal flashing. All damaged or deteriorated sheathing shall be replaced with new. End joints shall be made over a rafter. All existing roofing shall be removed before installing new roofing material. Sheathing attached to barge rafters shall extend back two trusses or rafters but in all cases no less than 4. Roofing nails shall penetrate through the roof sheathing. When new roofing is installed sagging portions of roof shall be braced with minimum 2 x4 lumber from roof rafter to nearest bearing wall. Purlins or sole plate shall be used when necessary. When a new roof is installed with aluminum fascia, drip edge, gravel stop, and flashing shall be matching aluminum. A roof sheathing inspection is required prior to dry-in. 18. Built-up Roofing Remove existing roofing material to bare deck. Repair sheathing and rafters where necessary. All new roofing material shall be governed by the Florida Building Code. 19. Shingle Roofing Remove existing roofing material to bare deck. Repair or replace damaged or deteriorated sheathing and/or rafters. Install FHA approved flashing and drip edge. New roofing shall be installed per the Florida Building Code and latest regulatory requirements. Roof shall have a minimum 25-year manufacturers warranty. 20. Mineral Surface Roofing Remove existing roofing material. Repair or replace damaged or deteriorated sheathing and/or rafters. Install new flashing and drip edge and apply mineral surface roofing material per manufacturer s specifications. 21. Granulated Modified APP - SBS Roofing Material Remove existing roofing material. Repair or replace damaged or deteriorated rafters and/or sheathing. Install new flashing and drip edge. Apply Rubberoid or equal brand according to manufacturer s specifications. Torch down only when safe to do so. 22. Roof Ventilation Install off ridge venting as specified by the manufacturer and /or work write up. Repair gable vents when necessary by installing new aluminum grills and screening. 23. Lead Boots All plumbing pipes through roof shall be flashed with lead boots. 10
16 Windows General Specifications 24. Windows Install new double pane windows, include new aluminum or fiberglass screens. All windows including egress windows shall be single-hung. (Hinge type swing out windows will not be accepted for egress.) Window openings shall be framed for standard size windows. New casing and trim shall be installed to match existing. Egress window shall be provided, at least one to each bedroom. All windows shall be caulked and made weather tight. All window installations shall be finished flush as possible to inner and outer wall surfaces. 25. Window Repair Repairs shall be as specified in the Work Write Up. Replace defective window locks. Windows shall operate properly and with ease of movement. 26. New Window Screens Replace existing screen frames with new aluminum frames and screens complete with new latches and hangers. All old hooks and latches shall be removed and all holes filled. Screens must be in frames and must be removable. 27. Window Screens Rescreening Rescreen indicated window screens using 18x4 aluminum mesh or fiberglass. Replace screen molding with new and replace all hooks and hangers. For aluminum framed screens remove spline and screen and install new screen with new spline rolled into frame. 11
17 Doors General Specifications 28. Door Repair Repairs shall include filling holes and cracks, replacing hardware, lock-sets, and hinges. Exterior door repairs shall include new doorstops with wood mounted weather stripping and aluminum thresholds. Doors shall operate properly without binding. Doors shall be painted according to paint specifications in this manual. When repairing doors the contractor will repair any surrounding area affected by his work. All repairs shall conform to the surrounding surfaces. 29. New Interior Doors Interior doors shall be 1-3/8 hollow core luan unless specified otherwise in the Work Write Up, complete with all hardware. Doors shall be pre-hung units unless otherwise noted. All surrounding areas shall be repaired as needed. Finish and paint as per painting specifications in this manual. 30. New Bi-Fold Doors Bi-Fold doors shall be hollow core luan doors on slider tracks unless specified otherwise Provide all hardware including pulls. Finish and paint as per painting specifications in this manual. 31. New Exterior Doors Exterior doors shall be 1-3/4 pre-hung metal doors with no lites. Doors shall include all hardware including lock-sets and deadbolts keyed alike. Surrounding areas shall be repaired and finished to conform to surrounding surfaces. Doors shall be painted as per the paint specifications in this manual. 32. Sliding Glass Doors Sliding glass doors as replacements for existing shall be aluminum framed with one or both sides operable depending on the function of the existing SGD. Sliding screen is to be included. Surrounding areas shall be repaired and finished to conform to surrounding surfaces. 33. Aluminum Screen Door Install a 5/8 aluminum pre-hung screen door with two separate screened sections with an aluminum protective grille. Mill finish, white, or bronze finish are acceptable depending on the homeowners choice of colors. All hardware to be included. 34. Wood Screen Door Install a 1-1/8 wood screen door with two separate screened sections with aluminum protective grille. Doors shall include all hardware and mechanical closer. Doors shall be painted as per the paint specifications in this manual. 12
18 Exterior General Specifications 35. Exterior Siding Clapboard, Bevel or Drop Install as indicated new wood siding. All joints shall be tight and all joints shall be staggered. Siding shall match existing unless otherwise agreed on by Rehabilitation Specialist. 36. Exterior Siding T1-11 Install as indicated new T1-11 siding. Install per manufacturer specifications including any necessary/required barriers. Paint siding as per the paint specifications in this manual. 37. Exterior Siding Vinyl Install vinyl siding on indicated areas. Siding is to be installed over minimum 6 mil. Vapor barrier or foil faced insulation. J channel inside, outside corners, starter strip, and all molding to finish around doors and windows shall be same manufacturer as siding. Siding and trim shall be installed per manufacturer specifications. 38. Exterior Finish Stucco Cover indicated areas with stucco finish. Stucco over frame construction shall include a 6 mil. Minimum vapor barrier and metal lath. Metal lath corner bead is to be used around all window and door openings as well as vent openings and termination points. A 3/8 scratch coat and ½ finish coat shall be applied. Texture shall be pre-approved by the rehab specialist upon contractor furnishing sample on site. 39. Soffit and Fascia Aluminum and/or Vinyl Soffit area to be level return ventilated material only. Fascia board installed or existing shall be covered with aluminum fascia of matching color. Soffit depth shall be no greater than 16 without support. Staples shall not be used for fastening soffit material. 40. Fascia Repair Remove deteriorated sections of wood fascia and replace material suitable for weather exposure. 41. Wood Soffit Replacement or Repair Install min. 3/8 exterior grade plywood to eave area. Plywood shall be flush with face wall of structure and butt to inside of fascia board. Soffit shall be at a 90 angle to face wall. Soffit shall be finished at the wall with molding. Fascia board attached to rafter tails at end cut shall be 1 x material or 2 x material depending on application and shall be indicated on work write up or pre-approved by the rehab specialist. Fascia material shall be approved for weather exposure. Ventilation shall be provided by using screen wire secured over 4 or 6 wide continuous opening or when matching existing conform to width. 42. Leaders and Gutters Where required, aluminum or galvanized gutters shall be installed over existing fascia or backstops with hangers as per manufacturer s specifications. Include concrete splash pads at all termination points of leaders. 13
19 Insulation General Specifications 43. Insulation Ceiling Insulation shall be Johns-Manville or equal and shall provide a minimum R-19 rating or as specified in the Work Write Up. Provide a 1 air space between roof decking and insulation baffle around perimeter of attic. All insulation shall be installed as per manufacturer recommendations and shall comply with the Florida State Energy Code. Ceiling and Wall General Specifications 44. Ceiling Finish Drywall Ceilings shall be 5/8 drywall. All joints, shall be taped and finished per manufacturer specifications and Work Write Up. All nails and/or screws shall be finished with drywall compound and sanded. Drywall shall be applied directly to ceiling framing unless otherwise specified in the work-write-up. Drywall shall be secured as per code. 45. Drop Ceiling Drywall Ceiling shall be 5/8 drywall finished according to manufacturer specifications and Work Write Up. Drywall shall be secured to new 2 x4 ceiling joists spaced max 24 on center. New joists shall be secured to existing and shimmed to obtain flat surface. 46. Ceiling Finish Popcorn Spray application of popcorn finish shall be done according to manufacturer s specifications. An even and consistent finish is expected. 47. Ceiling Finish Knock-Down Spray application of knock-down finish shall be done according to manufacturers specifications. An even and consistent finish is expected. 48. Ceiling and Wall Finish Veneer Plaster On existing plaster, fill all cracks and holes with non-shrinking filler. Apply stain retardant as needed. Apply bonding agent and veneer plaster (rough or smooth texture). Finished surface shall be uniform in texture and color. 49. Ceiling and Wall Finish Drywall On existing drywall repair all holes and damage to surface. All blow out patches and repairs shall be finished to match existing finish. 50. Wall Finish Drywall Apply new ½ drywall to existing studs. All joints taped and finished per manufacturer specifications. All nail and/or screws shall be finished with drywall compound and sanded smooth along with all joints. 51. Wall Finish Knock-Down Spray application of knock-down finish shall be done according to manufacturers specifications. An even and consistent finish is expected. 14
20 52. Wall and Ceiling Finish ¼ Drywall Laminate existing ceilings and/or walls with ¼ drywall. Drywall on ceiling shall be glued and secured with fasteners according to code. Drywall on wall needs only fasteners installed according to code. Finish as per all drywall specifications. 53. Wall Finish Paneling Installation of paneling shall include matching inside and outside corner trim, window and door trim, cover molding and base trim. When installing in conjunction with new windows, paneling shall return to window frames. Window sills shall be as specified in the Work Write-Up. Method of installation shall adhere to manufacturer specifications. 54. Painting Painting General Specifications All paint work shall be governed as per Painting General Appendix P Each coat of paint is to be inspected by the Rehabilitation Specialist. Please notify the Rehabilitation Specialist for your painting inspection. Cabinets - General Specifications 55. Cabinets Medicine Install a standard size recessed three shelf mirrored medicine cabinet centered over the lavatory. 56. Cabinet Vanity Lavatory base cabinets shall be ½ AC plywood or high-density board, 24 wide. Formica finish with doors unless specified otherwise. Cultured marble tops with molded sink, backsplash at all walls. 57. Cabinet Base Base cabinets shall be ½ AC plywood or high density board with formica finish unless specified otherwise. Doors, drawers, pulls, and shelves are to be included along with toe kick of the same material and finish. Caulk all joints where necessary. 58. Cabinets Wall Wall cabinets shall be ½ AC plywood or high density board with formica finish unless specified otherwise. Doors, pulls, and shelves are to be included. Caulk all joints where necessary. 59. Counter Top Counter tops shall be approximately 25 deep with a minimum 4 back splash. Tops shall be fitted to cabinets. Finish shall be formica with all edges finished unless specified otherwise. 15
21 Bathroom General Specifications 60. Wall Finish Ceramic Tile Remove existing materials on indicated walls. Apply ceramic tile to new concrete tile backer (Such as Dura-Rock or Wonderboard). Trim edges with bull-nose tile. Wall tile shall be a minimum standard grade 4 x4 x1/ Ceramic Fixture Set Install paper holder, toothbrush holder, two towel bars and a soap dish. Do not locate towel bars over paper holder. 62. Grab Bars Install two 24 x1-1/2 stainless steel grab bars. One horizontally in the tub area and the other installed adjacent to the water closet (34 to 38 above the floor.) Walls shall include solid wood backing for securing grab bars. Flooring General Specifications 63. Flooring Underlayment Underlayment shall be hardboard or plywood labeled as underlayment grade by the manufacturer. Thickness shall be designated in work write up. Fill all cracks, joints, and holes with appropriate compound suitable for such use. 64. Floor Covering Tile Install underlayment grade hardboard ¼ thickness. Install 3/32 vinyl tile using adhesive recommended by the manufacturer. When installing new floor covering shoe molding shall be installed or replaced with new and finished according to the paint specifications in this manual. 65. Floor Covering Sheet Vinyl Install underlayment grade hardboard ¼ thickness. Install sheet vinyl.090 gauge minimum over underlayment. Install using manufacturer s specifications. Shoe molding shall be installed or replaced with new and finished according to the paint specifications in this manual. 66. Floor Covering Carpet Repair all cracks, holes and soft areas in existing flooring. Install high-density 9/16 or equal padding. Install carpeting compete with jute or olefin backing only. 67. Base Trim Shoe molding is to be used for vinyl and tile floors unless otherwise designated in work write up. Colonial or clamshell base trim is to be used for carpeted floors. All base trim must match and all inside corners shall be coped and all outside corners shall be mitered. Vinyl cove molding is to be used in bathrooms unless otherwise designated in work write up. All wood trim is to be finished according to the paint specifications in this manual. 16
22 Appliances General Specifications 68. Appliances Install specified appliances per manufacturer s specifications and test for proper operation. Ranges to include oven window, clock with timer and electronic ignition for gas ranges. Refrigerators are to be two door and frost-free. 69. Range Hoods Shall be ducted or ductless according to work write up. Finish shall match the color of the appliances. Systems General Specifications 70. Mechanical Equipment Repair All equipment such as ranges, refrigerators, range hoods, heating and cooling equipment etc., shall be repaired and tested to assure safety and operation along with durability. 71. Heating -- All heaters will conform to applicable codes. A. Gas Indicated model shall be installed in area designated, to include blower system and tested for proper operation. No unvented gas heaters shall be accepted. All gas heaters shall meet with standard national approval and labeled by the National Gas Association. Size shall be determined by the Rehabilitation Specialist and must be test fired before final inspection. Contractor is responsible for all tank or meter installation fees and gas line installation fees. The contractor is not responsible for gas deposits. B. Electric Indicated models shall be installed in area designated and tested for proper operation. Individual heaters shall be on separate circuits as per the National Electrical Code. All electric heaters shall be equipped with forced air operation installed as per manufacturer's recommendations, and labeled a U.L. approved appliance. 72. Electrical All work shall conform to the latest adopted edition of the National Electrical Code. Installation of new or repair of electrical components shall not weaken or destroy any structural members of the building unit. All drilling, cutting, or altering to facilitate the installation/ repair of electrical work will require replacement/ patchwork to restore the areas affected to their original condition. All electrical fixtures and devices shall be U.L. approved. All light fixtures shall come equipped with the appropriately sized bulbs for that fixture and shall be of the energy mizer designation or similar approval. Spare bulbs for each fixture shall be included in the bid for future use by the owner. Electrical services shall be a minimum 150A and shall be sized to include a minimum of 2 spare circuits. All appliances shall be on separate circuits as dedicated circuits. Dishwashers shall utilize plug and cord disconnect. 17
23 Smoke detectors shall be provided and installed per NFPA 72. (110v. and battery backup) 73. Plumbing All plumbing shall comply with the latest adopted edition of the Florida Building Code-Plumbing. Installation of new plumbing/ repair work shall not weaken or destroy any structural portion of the building unit. Any cutting, drilling, alteration to facilitate the installation of plumbing will require replacement/ patching to restore the affected areas. All tubs, sinks, lavatories, water heaters and/or water closets when provided shall be installed complete. Showers shall include shower rods unless otherwise specified in the work write-up. All appliances shall include energy star or similar energy efficiency ratings. A. Electric water heaters shall be installed complete with pan, electrical disconnect, and pressure relief line to the outside of the building and shall provide a minimum 7 year warranty. B. Gas water heaters shall be installed complete with gas shut-off and be properly vented. No gas appliance unit shall be installed in bedrooms. C. Washing machines shall be installed with adequate access space to utilize and be installed with hammer arrestor to code. D. Tubs shall be a minimum 5 porcelain on steel, installed with shower rod. E. Shower base/ drain shall be one piece acrylic/ fiberglass units unless noted otherwise F. Tub Fixtures shall be replaced with each tub replacement unless otherwise noted, equipped with ant-scald device, bath filler, and shower head ( Heritage or equal ) G. Vanity Lavatory shall be one piece cultured marble with backsplash on all walls H. Water Closet shall be of water saver type American Standard Cadet model or equal. I. Sewer Trench and lay 4 PVC schedule 40 sewer pipe per code. Make complete connections at street stub-up and at dwelling with appropriate clean-outs. J. Septic Tank - Abandon tank. Pump tank and punch hole in bottom, fill with sand. Documentation of tank abandonment shall be provided. 18
24 K. Water line Trench to minimum 12 depth. Provide and install Min. ¾ schedule 40 PVC line, connect to water meter and dwelling per all applicable codes. Install anti-siphon devices for all required hose bib locations. L. Kitchen sink Replace with two compartment stainless steel sink, ledge mounted,swing spout faucet, stainless steel strainer, and all necessary fittings 19
25 74. Pest Extermination Pest Extermination General Specifications A. When termite treatment is specified, all structures on property are to be treated. The treatment shall be that treatment recommended by a bonded, licensed exterminator to rid the structures of any and all types of termites and shall carry a minimum warranty of one (1) year. B. Other treatment as specified. Chemicals used shall be those that will cause the least inconvenience to the property owner (moving of foam rubber articles, plants, etc.) Any damage to the structure, interior or exterior, or to the property (plants, etc.) caused by termite treatment, shall be repaired or replaced by the contractor. Pest extermination is considered to be a subcontract through the general contractor. Construction Debris General Specifications 75. Construction Debris Construction debris shall be removed from the premises and hauled away to an approved dump-site before calling for a final inspection. Site shall be left clean. 20
26 A.D.A. REQUIRMENTS This section is to be used only as a guide for estimating jobs. The actual A.D.A. Code shall be used for all specifications. 21
27 HANDRAILS, GRAB BARS AND TUB AND SHOWER SEATS General All handrails, grab bars and tub and shower seats required to be accessible. Size and Spacing of Grab Bars and Handrails The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface. If handrails or gram bars are mounted adjacent to a wall, the space between the wall and the grab bar shall be 1-1/2 in (38 mm) [See Fig. 39(a), (b), (c), and (e)]. Handrails may be located in a recess if the recess is a maximum of 3 in (75 mm) deep and extends at least 18 in (455 mm) above the top of the rail [see Fig 39 (d)]. Fig. 39 Size and Spacing of Handrails and Grab Bars 22
28 Ramps General Any part of an accessible route with a slope greater than 1:20 shall be considered a ramp. Slope and Rise The least possible slope shall be used for any ramp. The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16). Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises if space limitations prohibit the use of a 1:12 slope or less. (1) The landing shall be at least as wide as the ramp run leading to it. (2) All landings on ramps shall be not less than 60 inches clear, and the bottom of each ramp shall have not less than 72 inches of straight and level clearance. (3) If ramps change direction at landings, the minimum landing size shall be 60 in by 60 in (1525 mm by 1525 mm). Handrails If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides. Handrails are not required on curb ramps. Fig Components of a Single Ramp Run and Sample Ramp Dimensions Clear Width (1) The minimum clear width of a ramp shall be 36 in (915 mm). (2) Ramps that are part of a required means of egress shall be not less than 44 inches wide. Landings Ramps shall have level landings at bottom and top of each ramp and each ramp run. Landings shall have the following features. Handrails shall have the following features: (1) Handrails shall be provided along both sides of ramp segments. The inside handrail on switchback or dogleg ramps shall always be continuous. (2) Handrails on ramps which are not continuous shall extend not less than 18 inches beyond the sloped segment at both the top and bottom, and shall be parallel to the floor or ground surface (see Fig. 17). 23
29 Examples of Edge Protection and Handrail Extensions Fig
30 (3) The clear space between the handrail and the wall shall be 1-1/2 in (38 mm). (4) Gripping surfaces shall be continuous. (5) Top of handrail gripping surfaces shall be mounted between 34 in. and 38 in. (865 mm and 965 mm) above ramp surfaces. (6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post. (7) Handrails shall not rotate within their fittings. Cross Slope and Surfaces The cross slope or ramp surfaces shall be no greater than 1:50. Edge Protection Ramps and landings with drop-offs shall have curbs, walls, railings or projecting surfaces that prevent people from slipping off the ramp. Curbs shall be a minimum of 2 in. (50 mm) high (see Fig. 17). Outdoor Conditions Outdoor ramps and their approaches shall be designed so that water will not accumulate on walking surfaces. STAIRS Treads and Risers On any given flight of stairs, all steps shall have uniform riser heights and uniform tread widths. Stair treads shall be no less than 11 in. (280 mm) wide, measured from riser to riser [see Fig. 18(a)]. Open risers are not permitted. Nosings The undersides of nosings shall not be abrupt. The radius of curvature at the leading edge of the tread shall be no greater than ½ in (13 mm). Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal. Nosings shall project no more than 1-1/2 in (38 mm) (see Fig. 18). Handrails Stairways shall have handrails at both sides of all stairs. (1) Handrails shall be continuous along both sides of stairs. The inside handrail on switchback or dogleg stairs shall always be continuous [see Fig. 19(a) and (b)]. (2) If handrails are not continuous, they shall extend at least 12 in. (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser. At the top, the extension shall be parallel with the floor or ground surface. At the bottom, the handrail shall continue to slope for a distance of the width of one tread from the bottom riser; the remainder of the extension shall be horizontal [see Fig. 19 (c) and (d)]. Handrail extensions shall comply with 4.4. (3) The clear space between handrails and wall shall be 1-1/2 in. (38 mm). (4) Gripping surfaces shall be uninterrupted by newel posts, other construction elements, or obstructions. (5) Top of handrail gripping surface shall be mounted between 34 in. and 38 in (865 mm and 965mm) above stair nosing. (6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post. (7) Handrails shall not rotate within their fittings. Fig Usable Tread Width and Examples of Acceptable Nosings 25
31 LAVATORIES Exposed Pipes and Surfaces Hot water and drain pipes under lavatories shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories. BATHTUBS Floor Space Clear floor space in front of bathtubs shall be as shown in Fig. 33. Faucets Accessible lavatories shall have lever-operated faucets and narrow aprons which shall be mounted at a vertical distance of 28 inches, measured by the vertical distance from the finished surface of the floor to the bottom of the apron, and which shall allow for use of the lavatory by persons in wheelchairs [see Fig. 31 (b)] (a) With Seat in Tub If self-closing valves are used, the faucet shall remain open for at least 10 seconds. Height and Clearances Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor. Provide a clearance of at least 29 in (735 mm) above the finish floor to the bottom of the apron. Knee and toe clearance shall comply with Fig. 31 (a). Mirrors Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015 mm) above the finish floor [see Fig. 31 (a)]. (a) With Seat in Tub Fig. 31 (a) Lavatory Clearances (b) With Seat at Head of Tub Fig. 33 Clear Floor Space at Bathtubs 26
32 Seat An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. Grab Bars Shown in Fig. 33 and 34. Controls Faucets and other controls shall be located as shown in Fig. 34. Shower Unit A shower spray unit with a hose at least 60 in. (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided. Fig. 34 Shower Size and Clearances 27
33 Bathtub Enclosures If provided, enclosures for bathtubs shall not obstruct controls or transfer from wheelchairs onto bathtub seats or into tubs. Enclosures on bathtubs shall not have tracks mounted on their rims. SHOWER STALLS Size and Clearances The shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in. by 36 in. (915 mm by 915 mm). The shower stall in Fig. 35(b) will fit into the space required for a bathtub. Seat A seat shall be provided in shower stalls 36 in by 36in. (915 mm by 915 mm) and shall be as shown in Fig. 36. The seat shall be mounted 17 in. to 19 in. (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall. In a 36 in. by 36 in. (915 mm by 915 mm) shower stall, the seat shall be on the wall opposite the controls. Where a fixed seat is provided in a 30 in. by 60 in. minimum (760 mm by 1525 mm) shower stall, it shall be a folding type and shall be mounted on the wall adjacent to the controls as shown in Fig. 57. The structural strength of seats and their attachments shall comply with Fig. 35 Shower Size and Clearances 28
34 Structural Strength The structural strength of grab bars, tub and shower seats, fasteners, and mounting devices shall meet the following specifications: (1) Bending stress in a grab bar or seat induced by the maximum bending moment from the application of 250 lbf (1112N) shall be less than the allowable stress for the material of the grab bar or seat. (2) Shear stress induced in a grab bar or seat by the application of 250 lbf (1112N) shall be less than the allowable shear stress for the material of the grab bar or seat. If the connection between the grab bar or seat and its mounting bracket or other support is considered to be fully restrained, then direct and torsional shear stresses shall be totaled for the combined shear stress, which shall not exceed the allowable shear stress. (3) Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting device or the supporting structures, whichever is the smaller allowable load. (4) Tensile force induced in a fastener by a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable withdrawal load between the fastener and the supporting structure. (5) Grab bars shall not rotate within their fittings. Eliminating Hazards A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in. (3.2 mm). Controls Faucets and other controls shall be located as shown in Fig. 37. In shower stalls 36 in. (915 mm by 915 mm), all controls, faucets and the shower unit shall be mounted on the side wall opposite the seat. Shower Unit A shower spray unit with a hose at least 60 in. (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided. Fig. 36 Shower Seat Design (a) 36-IN. by 36-IN. (915 MM by 915 MM) Stall (b) 30-IN. by 60-IN. (760 MM by 1525 MM) Stall Fig. 37 Grab Bars and Shower Stalls 29 NOTE: Shower head and control area may be on back (long) wall (as shown) or on either side wall
35 Lead-Based Paint Maintenance Planning Tool 30
36 INTRODUCTION This Lead-Based Paint Maintenance Planning Tool is a guide designed for you to develop a custom fit checklist to conduct lead-based paint maintenance activities in a safe manner. Lead Job Check List Use the job checklist to help you recognize risky activities; plan and perform your work; and protect yourself, fellow workers, the residents, and your family from lead hazards. Materials Identify the materials (disposables) needed for the particular job by circling the picture of words. Equipment Circle the equipment needed for the particular job. Personal Protection Assign the protection the worker will need by circling the picture or words. Work Practices Circle the work practices that are appropriate to the task. Prohibited and Unsafe Practices Avoid these practices that jeopardize the health and safety of workers and residents. Cleanup Circle the cleanup practices appropriate to the job. As tasks are completed by the worker, the work practices are checked-off as used. For example, when you plan, circle tape, when you use it, cross it off. Carpet Removal Follow the different work practices required for this commonly performed activity. Decontamination Circle practices that are appropriate to the job. Quality Assurance When the job is finished, do a protecting check. The job is complete when you can answer all of the questions by circling Yes or NA (not applicable). 31
37 LEAD JOB CHECKLIST Resident Name: Job # Phone: Address/Apt. # 1. Was the building built before 1978? If you don t know when the building was built, treat the paint as lead-based paint. If the building was built after 1978, then lead-based paint is probably not present and this is not a lead job. 2. Could this job: Create lead dust that may contain lead? Yes No Disturb known or suspected lead-based paint? Yes No Require cleanup of dust or debris that may contain lead? Yes No Disturb known or suspected lead contaminated soil? Yes No 3. If Yes to any of the above, or if you don t know the answer to any of the questions, assume you are dealing with lead-based paint, and circle the level of risk below. Low Risk = Low levels of dust expected to be generated, and surface and paint in good condition, and less than two (2) square feet. High Risk = High levels of dust expected to be generated, or surface and paint in poor condition, or greater than two (2) square feet. 4. Who will do the job? Personnel must be properly trained and skilled. If they will have to wear a respirator, they must be medically qualified, fit-tested, and trained. 5. How will residents be notified and affected? Notification: Phone Letter Time Date Work area instructions to residents: Job scheduled: FROM: Time/Date TO: Time/Date Resident asked to leave unit: FROM: Time/Date TO: Time/Date Resident asked to move personal items? Yes No Temporary accommodation needed for resident? Yes No If Yes accommodation provided? Yes No If Yes, WHERE PHONE# 6. How will work be performed to minimize exposure to lead? Circle specific cards to use for this job: Materials Card Work Practices Card Carpet Removal Card Equipment Card Prohibited and Unsafe Practices Decontamination Card Personal Protection Card Cleanup Cards Quality Control Card 32
38 MATERIALS Circle needed materials (*Note: for high risk) Poly Film 6 mil polyethylene plastic or equivalent) Poly Bags 6 mil Tape Towelettes All-Purpose Cleaner, or cleaner made specifically for lead Tack Pads Rags String Mop Heads Circle needed equipment. Spray Mister Broom(Wet Sweep Only) Mop Handles Stapler Dust Pan(Wet Sweep Only) Buckets Scrapers Utility Knife HEPA Vacuum Signs/ Barrier Tape Mini Containment 33
39 PERSONAL PROTECTION Circle needed protection Protective Eye Wear Latex/Rubber Gloves Coveralls Gloves Disposable Cotton Disposable Full-Body Coveralls Recyclable Clothing Respirators W/HEPA Filters 34
40 WORK PRACTICES Circle needed work practices (*Note: for high risk) WORK SMART Protect and inform residents. Shutdown HVAC and/or isolate vents. Wear proper personal protective clothing. Remove/protect resident Belongings. Install 6 mil poly film securely. Be alert to special situations. poly Isolate area with 6 mil film. WORK WET Mist work area with water. Install catch bag under work area. Wet scrape, sand, pry, saw, plane, drill, and remove painted materials. Keep debris picked up. Foam drilling area. Control settled dust. WORK CLEAN Use tack pad. Use mini containment. 35
41 PROHIBITED PRACTICES UNSAFE PRACTICES 36
42 CLEANUP - LOW RISK Place large debris in 6 mil poly bags. Wet wipe with cleaner under and 2 beyond area that was covered with poly film. Wet wipe tools. Rinse wipe with water under and 2 beyond area that was covered with poly film. Mist debris on work area poly film. Gooseneck seal and label 6 mil poly bag. Fold poly film dirty side in. Place in poly bag and label. Remove all materials, tools and bagged debris from work area and residence. Wet wipe work area with cleaner. Properly dispose of bagged debris. Rinse work area with water. 37
43 CLEANUP HIGH RISK Place large debris in 6 mil poly bags. HEPA vac under and 2 beyond Area that was covered with poly film. Place contaminated tools/equipment in poly bag and seal. Mist small debris on work area poly film. Remove mini containment and place on poly film. Wet mop with cleaner under and 2 beyond area that was covered with poly film. Wring mop in separate bucket. Rinse mop with water under and 2 beyond area that was covered with poly film. Wring mop in separate bucket. Properly remove coveralls. Place disposable type on poly film or recyclable type in Laundry bag. HEPA vac under and 2 beyond area that was covered with poly film again. Fold poly film dirty side in. Place in poly bag and label. Gooseneck seal and label 6 mil poly bag. Wet wipe with cleaner the area that was repaired. Remove all materials, tools and bagged debris from work area and residence. Rinse work area with water. Properly dispose of bagged debris. 38
44 CARPET REMOVAL Circle needed work practices. CARPET FLOOR Mist carpet. HEPA vac floor area. Loosen wall to wall carpet from tack strips or glued areas. Cut carpet to manageable portions with utility knife. (about every 6 feet) Wet mop floor area, and baseboards with cleaner. Rinse mop floor area and baseboards. Roll carpet pile side in while misting carpet backing. PAD Cut padding to manageable portions with utility knife. HEPA vac floor area again. Roll pad while misting. Wrap carpet & padding in 6 mil poly, seal with tape, and remove from area. 39
45 DECONTAMINATION Circle needed work practices PERSONAL Shower with soap. HEPA Vacuum clothing with vacuum. with Wipe hands and face towelettes. Send recyclable coveralls to the special laundry. or Launder clothes separately. Wash face and hands with soap and water before eating, drinking, smoking, or applying cosmetics and at finish of job. EQUIPMENT Clean tools and equipment away from the work area. QUALITY ASSURANCE Did you do your part to inform and protect everyone from lead poisoning? Work properly completed as requested Yes No N/A* Work areas cleaned properly Yes No N/A Contaminated debris properly bagged, sealed and labeled Yes No N/A Resident s belongings returned to original place Yes No N/A Resident notified of job completion Yes No N/A Other lead problems noted Yes No N/A If Yes, other lead problems reported Yes No N/A Signature Date/Time Unit/Address *N/A means not applicable 40
46 APPENDIX P WORKMANSHIP AND APPLICATION CONDITIONS: 1. All materials and labor will have a minimum one (1) year warranty. 2. Paint only in dry weather when temperature is 50 degrees Fahrenheit or higher. Stop exterior work early to permit paint film to set up before condensation caused by night temperature drops occur. Do not begin painting until all surfaces are moisture free. 3. Sweep dust, dirt and debris away before painting. 4. Follow all directions on labels when applying paint. Contractor s work must conform to the manufacturer's paint instructions on the labels and product data sheets. 5. Paint only dry surfaces (less than 15%, moisture). Cementious substrates' moisture content must not exceed 25% prior to coating application. 6. All work shall be accomplished by skilled workmen familiar with and trained to do this type of work, they shall be qualified to operate or use equipment and rigging needed to accomplish the work. 7. All equipment shall be in sound working condition and must meet all OSHA Safety Standards. All workers must be trained in the operation of all equipment used on this project. 8. Materials shall be applied evenly free of runs, sags, pinholes or lap marks. 9. Only manufacturer's thinners may be used to thin the respective products and in the amounts prescribed. 10. All shrubbery, outside carpeting, water tanks, sprinkler systems and other equipment not listed shall be fully protected against damage during each stage of the painting project. 11. All exterior substrates designed not to receive paint shall be kept free of paint residue. 12. Normal safety signs, necessary lighting and temporary fencing around work areas shall be installed and maintained in accordance with OSHA requirements while work is in progress. 13. The Contractor will perform all work using accomplished and skilled craftsmen familiar with and trained to perform the scope of work specified. They will also be qualified to operate and/or use all equipment. 14. The Contractor shall see that all surface preparation and material application is performed in accordance with label directions, product technical data sheets, the written specification contained herein, and standard industry practices. Failure of the paint and/or coating system due to improper surface preparation, application: or material usage or handling is solely the responsibility of the Contractor. 41
47 15. The Contractor will see that all substrates are completely dry and moisture free prior to the application of any and all material. The Contractor will take into consideration the humid climate of Florida during the application process of all work. 16. The Contractor will apply material in accordance with the Manufacturer's approved product data sheet instructions to achieve specified dry film thickness (DFT). The Contractor will apply material at a rate not exceeding that recommended by the Manufacturer for the surface being coated. 17. The Contractor will apply finish coats in a manner that yields a smooth finish, free of brush marks, streaks, laps or pile-ups of material, skips or holidays. 18. The Contractor will be responsible to see, by reasonable and visible conformation, that all surfaces to be finished are free of defects from substrate and/or previous applicators. Defects that may affect his application finish appearance, which cannot be corrected shall be documented to Owner and/or Project Coordinator prior to application of finish material. 19. Abutment of edges of different material or color will be a sharp, clean cut off and will not overlap GENERAL SURFACE PREPARATION: 1. The Contractor is responsible to see that all surfaces and substrates to be primed, sealed, painted, stained, or waterproofed are clean and free of foreign material, dust, dirt, grease, oil, or any substance which may adversely affect the performance of the coating before the application process begins 2. The Contractor is responsible for the complete removal of all mildew spores and organic growth. Apply a solution of 2/3 cup trisodium phosphate, 1/3 cup detergent (such as "Tide"), and 1 quart of non-ammoniated chlorine (pool chlorine is preferred) with 3 quarts water to make a 1 gallon solution. It is recommended to apply a test sample to ensure the ratio of chlorine to water is strong enough to adequately kill the mildew, Apply the approved solution to all affected areas and allow to remain on the surface for 10 to 30 minutes. Using a course nylon bristle brush, scrub all affected areas, as needed. Rinse thoroughly to ensure all residue has been removed. 3. The Contractor is responsible to see that special attention is given to previously painted chalky surfaces. Thorough pressure cleaning must be performed whenever chalk is present. Regardless of how much chalk is removed, complete coverage of the substrate with a bonding sealer must be performed. 4. The Contractor is responsible to see that all surfaces to be coated will be pressure cleaned with a minimum of 2500 p.s.i. at a flow rate of no less than 4 gallons per minute. This process should perform the removal of all chalky, blistered, peeling, and cracking paint, dirt, dust, mildew, organic matter, cobwebs, grease, tar, and any foreign matter that may affect the adhesion and performance of the finish coat. 5. The Contractor is responsible to see that all masonry cracks and voids are repaired as per instructions listed under Section 9 Masonry Surfaces / Crack and Void Treatment Any deteriorated or failed caulk, sealant and/or patching compounds should be removed before 42
48 applying primers. block fillers or surface conditioners and prior to reapplying caulk, sealants and/or patching compounds. 6. The Contractor is responsible to remove all efflorescence. Apply a solution of 1 part muriatic acid to 5 parts water and apply to all affected areas. Using a course nylon bristle brush, scrub all affected areas. Allow to remain for 10 to 15 minutes. Rinse thoroughly to ensure that all residue has been removed. 7. The Contractor is responsible to see that all previously painted glossy surfaces are deglossed with an approved de-glosser/degreaser and abraded before the paint application process begins. The edges of remaining old paint should be feathered to give the repainted surface a reasonably smooth appearance. 8. The Contractor is responsible to see that all surface rust and mill scale is removed in accordance with the Steel Structures Painting Council. This process should be performed to a minimum of SSPC-SP-2, Hand Tool Cleaning or SSPC-SP-3, Power Tool Cleaning. 9. The Contractor is responsible for notifying the Builder and/or Project Coordinator of all wood that is warped, cracked, water damaged or delaminating is repaired or replaced nails should be counter sunk nail holes and small cracks should be filled prior to painting. MASONARY SURFACES: 1. Over a thoroughly cleaned surface, apply one coat of Color Wheel 950 Ti-Gard Conditioner, or approved equal, to all previously painted chalky surfaces receiving finish materials. When the sealer has dried, the surface should present a low or eggshell sheen. To determine proper reduction, it is recommended to do test applications prior to commencement of work. 2. Apply at a spread rate of no greater than 450 square feet per gallon. 3. Apply in an even, uniform manner, avoiding sags and runs Apply by brush, roller or spray application, maintaining a wet edge. Work material into the pores of surface. Brush material into cracks to be detailed. 4. Allow a minimum of 24 hours curing time before recoating. 5. Remove any deteriorated caulking or sealant around aluminum, metal or wood windows, doors, exterior decorative bands or anywhere caulking or sealant has been applied. Determine that surface is clean and free of foreign material, mildew, moisture, dirt, sanding dust, ceiling texture or any substance which may adversely affect the performance of the sealant before the application process begins. Thoroughly apply sealant to all joints, seams, miters, voids, tops, sides and bottoms of interior trim, tops, sides and bottoms of exterior bands, corners and junctures where any dissimilar materials, masonry and nonmasonry surfaces (i.e. masonry to wood trim) meet and drywall and non-drywall surfaces (ie interior drywall to interior wood trim). 6. Apply a continuous bead of Color Wheel Optima 50 Year Acrylic Urethane Sealant (RCS- 4), or approved equal, to all areas described above and to all dissimilar materials - masonry to wood trim, metal to wood, etc., and any exposed area where water could enter behind paint film or substrate and cause damage. Tool or stipple to match surrounding substrate 43
49 texture. For best results, cured beads should be between 1/8"-1/2" wide and 1/8" -1/4" deep. 7. Allow a minimum of four to six hours (depending on climatic conditions) drying time before painting. 8. Shrinkage or Hairline Cracks (1/32 or less): Apply Kover Krack Brush Grade Elastomeric Patching Compound, or approved equal, (Smooth or Textured) generously working firmly into crack or void (thickness should be 1/32" at center) see diagram 1 Using a broad knife or a brush, feather" or stipple the material on each side, thickness of 1/32" at center should be smoothed to 0" over a 2-inch area. This gradual reduction in thickness helps conceal the patch and allows the elongation characteristics of the patching compound to work effectively, this technique will also help to match the surrounding substrate texture so as not to appear as an obvious patch. 9. Non-Structural Movement Cracks (1/32 to 1/16 ): 9.1 To cracks and voids equal to 1/32" apply Kover Krack Brush Grade Elastomeric Patching Compound, or approved equal, (Smooth or Textured) generously working firmly into crack or void (thickness should be 1/16" at center) same as diagram 1 and instruction above. 9.2 Cracks and voids 1/32" to 1/16" should be routed larger than 1/16" wide and 1/16 deep to form a v-shape, see diagram 2. Flush with water, allow to dry thoroughly. Prime area with Color Wheel 1252 Quick Cure Acrylic Conditioner or approved equal. Insert appropriate size closed cell foam backer rod, if needed. Apply Lighthouse Products RCS-4 Acrylic Urethane High Performance Sealant or approved equal. Gun material firmly into crack or void (firmly secure backer rod, if used), leaving no pockets. 9.3 Allow polyurethane sealant to thoroughly cure and coat with Kover Krack Knife Grade Elastoreric Patching Compound, or approved equal, (Smooth or Textured) thickness should be 1/32" at center. 9.4 Using a broad knife or a brush, "feather" or stipple the material on each side, thickness of 1/32' at center should be smoothed to 0" over a 2-inch area. This gradual reduction in thickness helps conceal the patch and allows the elongation characteristics of the patching compound to work effectively. This technique will also help to match the surrounding substrate texture so as not to appear as an obvious patch. 44
50 10. Apply one coat of Color Wheel Flex Lox 1240 Line Exterior Coating, or approved equal. 11. Apply at a spread rate of no greater than 200 square feet per gallon to achieve a minimum dry film build of no less than 3,6 mils and until a solid and uniform finish is achieved. 12. Apply by brush, roller or spray application. Maintain a wet edge Apply at such a rate as to avoid runs and sags. 13. If airless spray is used on porous surfaces, back roll/brush all surfaces with a wet roller/brush. Work material into pores until a solid (pinhole free) finish is achieved. 14. Allow a minimum of 4 hours curing time if recoating is to be performed. Note: Specification may list paint systems as one and/or two finish coat, due to certain tinted colors, low hiding colors or radical color changes, industry standards may require the addition of more finish coats. DRYWALL CEILINGS (BREEZEWAYS, BALCONY, PATIO, etc. Note: Determine that surface is clean and free of foreign material, mildew, moisture, dirt, or any substance which may adversely affect the performance of the coating before the application process begins. If chalk or oxidation is present on the surface affect cleaning a chalk binding primer must be used prior to application of spot primer and finish. Primer: 1. Spot prime any new areas, bare areas and imperfections with one coat of Color Wheel Optima 330 All Prime or approved equal. 2. Apply at a spread rate of no greater than 350 square feet per gallon to achieve a dry film build of no less than 1 6 mils and until a solid and uniform finish is achieved. 3. Work material into pores until a solid (pinhole free) finish is achieved. Maintain a wet edge. Apply at such a rate as to avoid runs and sags. 45
51 4. Allow a minimum of 4 hours drying time, then lightly sand before recoating. Finish: 1. Apply one coat of Color Wheel Flex Lox 1240 Line Exterior Coating or approved equal. 2. Apply at a spread rate of no greater than 350 square feet per gallon to achieve a minimum dry film build of no less than 2.0 mils and until a solid and uniform finish is achieved. 3. Apply by brush, roller or spray application Maintain a wet edge. Apply at such a rate as to avoid runs and sags. 4. If airless spray is used on porous surfaces back roll/brush all surfaces with a wet roller/brush. Work material into pores until a solid (pinhole free) finish is achieved. 5. Allow a minimum of 4 hours curing time if recoating is to be performed. Note: Specification may list paint systems as one and/or two finish coat, due to certain tinted colors, low hiding colors or radical color changes, industry standards may require the addition of more finish coats. 46
Estimating Database Checklist
Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to
COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)
COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.
IMPROVEMENT COST ESTIMATE powered by HomeFixers
IMPROVEMENT COST ESTIMATE powered by HomeFixers 123 Main St, Anytown, USA 12345 2000 SF $ 45,041.06 100.0% $22.52 per sq. ft. Stage 1: Pre-Construction $ 1,461.00 3.2% 1 House Secured $ 106.00 0.2% Lockbox
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Inspection Item COMMENTS
APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:
Mike and Jen Sample 111 Main St. Tabb, VA. 23699 888-9999 SPECIFICATION LIST
Mike and Jen Sample 111 Main St. Tabb, VA. 23699 888-9999 SPECIFICATION LIST 10. PLANS AND PERMITS The Contractor shall provide all necessary plans and procure permits for building, plumbing, electrical,
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Scope for Irvinton Village Unit #512 Overall Scope: Demolition, Renovation, and
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
Uncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
Cost Estimate. Page 1. Description Qty Price UM Draw Me Total. LAND 5 Lot Price 6 Closing Costs on Lot 7 Interest On Lot 8 9
Page 1 1 2 3 4 IMPORTANT: BE SURE TO INCLUDE SALES TAX AND DELIVERY CHARGES LAND 5 Lot Price 6 Closing Costs on Lot 7 Interest On Lot 8 9 TOTAL LAND (LINES 5-7) 10 11 DESIGN 12 * Architecture 13 Engineering
PDmB, Inc. Definitions
Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or
Total Home Inspection Checklist
Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
Vision Home Inspection
Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
How To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
RRIO Checklist. Use of checklist: Definitions: Limitations
CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units
Inspecton Report. Property Address:
Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 [email protected] www.nationalhomeservices.com Property Address: 873
Self-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
Mobile Home Pre-Inspection Checklist
Mobile Home Pre-Inspection Checklist TWO (2) STEP INSPECTION PROCESS STEP ONE: CALL FOR THE FIRST INSPECTION WHEN THESE ITEMS ARE COMPLETE. 1. Septic tank installed and plumbing complete. (SEE PLUMBING
Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000
Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Your Basement Remodeling Specialist LLC
Your Basement Remodeling Specialist LLC Contents Introduction 3 Remodel Details 4 Basement Bid Scope 5 Financial Arrangements 6 Homeowners Shopping Guide 7 The following is provided with your actual quote:
Holz Choices & Specifications
March 21, 2011 0. SALES AND DESIGN 1. UTILITIES AND PERMITS Holz Choices & Specifications 2. EXCAVATION AND LOT PREPARATION Job Beginning date of Monday May 2 nd, 2011 ALTERNATE: Garage walls as drawn
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
Summit Series Single Section and Double Section Homes
Single Section and Double Section Homes SM-01 All New 20 Wides Now Available! SM-08 Units shown with optional features SM-01-4814 42 Bedrooms 41 Bathrooms 648 Sq. Ft. SM-01-5214 42 Bedrooms 41 Bathrooms
Schedule of Maintenance Fees
Schedule of Maintenance Fees Effective July 1, 2015 It is the policy of the Housing Authority of Murray not to charge for NORMAL wear and tear. However, the Housing Authority reserves the right in every
Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division
Code Enforcement Inspection Manual City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division LIVING ROOM 304.15 EXTERIOR DOOR(S) Check door(s) and trim for condition,
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
Cascade Remodeling Inc. PO Box 25687 Portland, OR 97298 Catalyzing Euphoria Phone (503) 297-2055, FAX (503) 297-0579 CCB # 67007
SPECIFICATIONS For Sample Customer SCOPE OF WORK: The contractor will provide labor and/or materials for the work as outlined in the estimate and the following specification. The contractor s estimate
Substantial Improvement/Damage (FEMA 50% Rule) Frequently Asked Questions and Information
SUBSTANTIAL IMPROVEMENT/DAMAGE WORKSHEET (FEMA 50% RULE) South County: Development Services North County: Development Services 4000 Tamiami Trail S. Room 122 1001 Sarasota Center Blvd Venice, Florida 34293-5076
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
How To Repair A House
Assessing Structural Damages Please note-this presentation is only intended to be used as a basic educational tool and is by no means all encompassing. Each property should be treated on a case by case
Patio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111
A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
COMPREHENSIVE PROPERTY INSPECTIONS
COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Home Inspection Report
Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
Real Estate Inspection Report
1010 22nd Ave N Naples, Florida 34103 Real Estate Inspection Report 470 Golden Gate Blvd W Naples, Florida 34120 Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage
City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage Property Address: Company Name: Contractor Name: Contractor Address: City: State: Zip: License Number: Phone Number
Rehab Inspection Report Page 1
Rehab Inspection Report Page 1 Home Address: Construction Style: Number of bedrooms Square footage: Value of offer: Estimated rehab cost: Value of resale: Orientation of house: N S E W Note: orientation
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Typical Finished Basement Details
Fauquier County, Virginia Typical Finished Basement Details Based on the 2012 International Residential Code Finished basements must be constructed in conformance with this document. For requirements,
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
Pre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
HOME INSPECTION CHECKLIST
CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
Important Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
Propery Inspection Report
Propery Inspection Report Cover Page,, Ok Inspection prepared for: Date of Inspection: 9/28/2014 Time: 8:30 AM Age of Home: 2011 MOL Weather: Clear 62 degrees Inspector: License #130 5400 Hwy 177, Marland,
PUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through
#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check
#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility
Inspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com [email protected]
QUOTATION FOR EXAMPLE BATHROOM RENOVATION
QUOTATION FOR EXAMPLE BATHROOM RENOVATION Prepared For: PEGASUS Client 99 Washington St Melrose, MA 02176 Quotation valid for 90 from: 12/21/10 PEGASUS Design-To-Build is pleased to have the opportunity
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Bath Planning Guidelines With Access Standards
Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Residential Building Inspection Policies
CONCRETE 1. A footing inspection has been called in, but a monolithic slab shows on the plans. Cancel the footing and create a slab inspection, as long as there is a Passed Plumbing Rough (05). 2. A stemwall
GENERAL ELECTRICAL REQUIREMENTS
GENERAL ELECTRICAL REQUIREMENTS RECEPTACLE SPACING Within 6-feet of the edge of any door HABITABLE Not more than 12-feet apart along wall ROOMS: At all wall spaces 24 or more wide Within 24 of edge of
Vari Inspection Services
Cover Page Vari Inspection Services Property Inspection Report Inspection prepared for: Sample Real Estate Agent: None - Date of Inspection: 5/13/2015 Inspector: Tony Vari License # HI8047 23110 STRD 54
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
SUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
The replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
Acceptable Donations List
Acceptable Donations List Thank you so much for you donation to Habitat for Humanity, through your contribution Habitat is able to fund house construction and continue to follow our mission as a non-profit
