Montageanweisung Notice de montage Assembly Instruction NGR 3-18

Size: px
Start display at page:

Download "Montageanweisung Notice de montage Assembly Instruction NGR 3-18"

Transcription

1 NGR Base Frame Montageanweisung Notice de montage Assembly Instruction Mounting Sequenz A1 E2 1 / 14

2 NGR Microduct Management Cable entry top Mounting Sequenz A1 C1 2 / 14

3 NGR Microduct Management Cable entry bottom Mounting Sequenz A1 C1 3 / 14

4 NGR Patch Cord Management-Side Access Mounting Sequenz A1 C1 4 / 14

5 NGR Patch Cord Management - Front Access Mounting Sequenz A1 D1 5 / 14

6 NGR Cable entry Montageanweisung Notice de montage Assembly Instruction Mounting Sequenz A1 A5 6 / 14

7 NGR Patch Cord Routing Channel Mounting Sequenz A1 A3 7 / 14

8 NGR Patch Cord Routing Channel for Microduct Mounting Sequenz A1 A3 8 / 14

9 Assembly Instruction Montageanweisung Notice de montage NGR Mounting together Mounting Sequenz A1 B2 9 / 14

10 NGR Walls and Roof Montageanweisung Notice de montage Assembly Instruction Mounting Sequenz A1 C1 10 / 14

11 NGR Doors Montageanweisung Notice de montage Assembly Instruction Mounting Sequenz A1 C1 11 / 14

12 NGR Components Montageanweisung Notice de montage Assembly Instruction 12 / 14

13 NGR Zubehör/Accessoires Pos. Artikel VPE SAP-Nr. HUBER+SUHNER Nr. 1. NGR ODF-Rack Top Entry (B900xT300xH2200) NGR ODF-Rack Bottom Entry (B900xT300xH2200) NGR Türensatz, geteilt 600/300, für KABA Schliessung 4. NGR Seitenwand, links oder rechts NGR Abfangplatte für 4 Erdkabel, Erweiterung NGR Befestigungsbügel für Abfangplatte NGR Bodenabdeckung für Hohlbodenmontage NGR Deckenbestigung, 1000mm NGR Rückwand NGR LISA Spleisskassette 24Fs LC/APC ANT TrayUnit, 6 HE Dokumentenhalter, 1 HE Schutzrohr, geschlitzt 100m Einziehwerkzeug für Schutzrohr, geschlitzt FiberTray Label 1 24, 1 84 fortlaufend, selbstklebend 16. Kit Schutzrohr, geschlitzt, nummeriert, Set abgestuft, oben 17. Schutzrohr, geschlitzt 5m Kit Schutzrohr, geschlitzt, nummeriert, 1-84 abgestuft, unten 1 Set Pos Produit Unité SAP- No. HUBER+SUHNER No. 1. NGR ODF-Rack Top Entry (B900xT300xH2200) NGR ODF-Rack Bottom Entry (B900xT300xH2200) 3. NGR jeu de portes NGR panneau latéral, gauche ou droit NGR plaque de fixation des cables NGR rail pour fixation des rilsans NGR couvercle pour faux plancher NGR fixation de plafond, 1000mm NGR panneau arrière NGR LISA cassette de raccordement 24Fs LC/APC ANT 11. TrayUnit, 6 U Support de documents, 1 U Tube de protection annelé 100m Outil pour tube de protection annelé FiberTray Label 1 24, 1 84 autocollant de réperage 16. Kit pour tube de protection annelé, gradué de 1 à 1 Set , en haut 17. Tube de protection annelé 5m Kit pour tube de protection annelé, gradué de 1 à 84, en bas 1 Set / 14

14 Pos. Product Unit SAP- No. HUBER+SUHNER No. 1. NGR ODF-Rack Top Entry (B900xT300xH2200) NGR ODF-Rack Bottom Entry (B900xT300xH2200) NGR door set, separated 600/300, for KABA-lock NGR sidepanel, left or right NGR cable fixing plate NGR cable tie rail NGR cover for raised floor NGR ceiling fixation, 1000mm NGR back wall NGR LISA splice cassette 24Fs LC/APC ANT TrayUnit, 6 U Document holder, 1 U Conduit slotted 100m Tool for conduit slotted FiberTray Label 1 24, 1 84 consecutive, selfadhesive Conduit kit, slotted, numbered, 1-84 staged, top 1 Set Conduit slotted 5m Conduit kit, slotted, numbered, 1-84 staged, bottom 1 Set / 14

> CABLE 3 MM / 3 MM CABLE COMPONENTS

> CABLE 3 MM / 3 MM CABLE COMPONENTS C3100 KIT POUR FIXATION SOL-PLAFOND (4 MÈTRES) - Fixation haute Ø 18,5 mm - Câble en acier inoxydable L. 4 m - Fixation basse avec tendeur (Clé Allen et vis fournies avec le Kit) FLOOR / CEILING FIXING

More information

NÜVO REVO 270. 900 mm 810 x 810 x (660-860) No. Description

NÜVO REVO 270. 900 mm 810 x 810 x (660-860) No. Description REVO 70 Use these instructions for the following items / Suivez ces instructions pour les items suivants -7-4 007 Cabinet / Caisson Size / Dimension 900 mm 0 x 0 x (660-60) No. Description Qty / Qté. Upper

More information

Repair Parts List. Valor Model 530X NG/LPG Gas Fireplace Heater. Manufactured by. Of British Columbia, Canada 4000306-01

Repair Parts List. Valor Model 530X NG/LPG Gas Fireplace Heater. Manufactured by. Of British Columbia, Canada 4000306-01 Valor Model 530X NG/LPG Gas Fireplace Heater Repair Parts List Manufactured by Of British Columbia, Canada 4000306-0 Because our policy is one of constant development and improvement, details may vary

More information

Wall Mounted Products

Wall Mounted Products Metallic Indoor PK Termination Boxes Prysmian Part Numbers: see below Metallic PK Termination Boxes are designed for the termination, branching and distribution of fibre optic cables in telecommunication,

More information

SURFOX 304 MIG & TIG 54-D 314 (120V) & 54-D 334 (230V) MARCH 2015 1.48-R 461 5. 48-R 462 2. 48-R 313 3. 48-K 419 4. 48-S 114 6. 48-S 128 7.

SURFOX 304 MIG & TIG 54-D 314 (120V) & 54-D 334 (230V) MARCH 2015 1.48-R 461 5. 48-R 462 2. 48-R 313 3. 48-K 419 4. 48-S 114 6. 48-S 128 7. A 1.48-R 461 5. 48-R 462 2. 48-R 313 6. 48-S 128 3. 48-K 419 4. 48-S 114 7. 48-R 314 9.48-R 463 8. 48-R 136 10. 48-R 105 11. 48-R 254 12. 48-R 109 13. 48-R 321 14. 48-R 214 B 15. 48-K 420 16. 48-S 228

More information

YALE ERP 16/18/20 VT/VF - MWB

YALE ERP 16/18/20 VT/VF - MWB ERP 6/8/0 VT/VF - MWB LIVRET PIECES DE RECHANGE SPARE PARTS CATALOGUE Référence : SZ0.0.4 Edition 0 ERP 6/8/0 VT/VF - MWB SOMMAIRE SUMMARY PANNEAU AVANT - SZ0..908 FRONT PANEL PANNEAU ARRIERE - SZ0..84

More information

BAGAGE & BAGGAGE & AANHANGWAGEN REMORQUAGE TRAILER

BAGAGE & BAGGAGE & AANHANGWAGEN REMORQUAGE TRAILER BAGAGE & AANHANGWAGEN BAGAGE & REMORQUAGE BAGGAGE & TRAILER 9 132 132 BAGAGE EN AANHANGWAGEN BAGAGE ET REMORQUAGE BAGGAGE AND TRAILER BAGAGE EN AANHANGWAGEN BAGAGE ET REMORQUAGE BAGGAGE AND TRAILER part

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION UR Series LED Upgrade Kit Includes: 48" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL

More information

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 7 03 Litho In U.S.A. (cre) 1 Part No. OVEN PARTS NOTE: The screws and nuts required to attach a part are listed immediately following that part.

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave

More information

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

FACT OPTICAL DISTRIBUTION FRAME SYSTEM Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from

More information

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS EHD TRACK LEVEL, (SET LEVEL ON PLASTIC HEADER. DO NOT PLACE LEVEL ON ALUMINUM TRACK.) TRACK IS FLUSH WITH TOP OF HEADER JUNCTION BOX IDLER PULLEY LOCATOR PINS LOCATOR PINS OPERATOR DOOR STOP JUNCTION BOX

More information

Optical Cable Entry Facility (OCEF) Installation Instructions

Optical Cable Entry Facility (OCEF) Installation Instructions Instruction Sheet 860380690 Issue 4, February 2014 Uniprise Solutions Optical Cable Entry Facility (OCEF) Installation Instructions General The Optical Cable Entry Facility (OCEF) cabinet stores optical

More information

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U Applications The High Density Cabinets are suitable for Central Offices and can be used as fiber nodes and termination points

More information

SUPPORTS DE TABLETTES SUR CABLES OU TIGES INOX CABLE AND ROD SUSPENDED DIPLAY SYSTEMS

SUPPORTS DE TABLETTES SUR CABLES OU TIGES INOX CABLE AND ROD SUSPENDED DIPLAY SYSTEMS SUPPORTS DE TABLETTES SUR CABLES OU TIGES INOX CABLE AND ROD SUSPENDED DIPLAY SYSTEMS FT789 0105 Ajouter 6 de chaque côté des pochettes porte-affiche pour déterminer la distance entre les câbles. Add 6

More information

1U Multi-Function Fibre Enclosure

1U Multi-Function Fibre Enclosure FEATURES AND SPECIFICATIONS Features and Benefits The is a configurable rack mount unit for storing and terminating incoming fibre cable. The fibre enclosure has been designed to accommodate various termination

More information

DIGITUS Network & Server Cabinets. UNIQUE Series

DIGITUS Network & Server Cabinets. UNIQUE Series DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door

More information

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

19 Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted. 19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile

More information

ADC-APC Integrated Cisco Data Center Solutions

ADC-APC Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the

More information

INSTALLATION STANDARD FOR PRE-CABLING A BUILDING FOR FIBRE BROADBAND

INSTALLATION STANDARD FOR PRE-CABLING A BUILDING FOR FIBRE BROADBAND INSTALLATION STANDARD FOR PRE-CABLING A BUILDING FOR FIBRE BROADBAND 1 Table of Contents 1 GENERAL... 3 1.1 Purpose... 3 1.2 Reference Documentation... 3 1.3 Prerequisite... 3 1.4 Defects... 3 1.5 Deviations...

More information

Dimensions (HxDxW) Total Cabinet Area 89.96x 39.69 x 24 in/ 2,285 x 1,008.17 x 612.77 mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.

Dimensions (HxDxW) Total Cabinet Area 89.96x 39.69 x 24 in/ 2,285 x 1,008.17 x 612.77 mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812. 1 Compaq 10000 Series Racks The 10000 series racks are a family of 1000mm deep racks which are available in 22U, 36U, 42U and 47U 600mm widths. Compaq 10000 Series Racks provides a common, integrated platform

More information

SERRURES À CONTACT ET DIVERSES SWITCH LOCKS / VARIOUS LOCKS KONTAKTSCHLÖSSER / VERSCHIEDENE SCHLÖSSER

SERRURES À CONTACT ET DIVERSES SWITCH LOCKS / VARIOUS LOCKS KONTAKTSCHLÖSSER / VERSCHIEDENE SCHLÖSSER SWITCH LOCKS / VARIOUS LOCKS KONTAKTSCHLÖSSER / VERSCHIEDENE SCHLÖSSER 161 Ø 19,1 mini SERRURES À CONTACT ET DIVERSES 1017 1,8 19,2 32,1 M5x100 Ø20 13,7 Course 8 6,8 25,6 Ø17,5 M19x100 Ø7,5 162 Observations

More information

INSTALLATION GUIDE. Optical Fibre Patch Panel 48 fibre LC. Nexans Cabling Solutions Installation Guide 48 fibre LC panel page 1

INSTALLATION GUIDE. Optical Fibre Patch Panel 48 fibre LC. Nexans Cabling Solutions Installation Guide 48 fibre LC panel page 1 Optical Fibre Patch Panel 48 fibre LC INSTALLATION GUIDE Optical Fibre Patch Panel 48 fibre LC Nexans Cabling Solutions Installation Guide 48 fibre LC panel page 1 Document Information Release July 2006

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

Fiber Optics TII FDH1. Indoor Fiber Distribution Cabinet

Fiber Optics TII FDH1. Indoor Fiber Distribution Cabinet TII FDH1 Fiber Optics Indoor Fiber Distribution Cabinet Fiber Optics. A Division of Tii Network Technologies Inc. 5103 Pegasus Ct., Suite H Frederick, MD 21704 Contact 888-844-4720 301-874-4688 fibersales@tiinetworktechnolgies.com

More information

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets Complete underfloor box for one Modul 45 socket and two data connection sockets Screed height 105-165 mm In the field of complete service outlets, the GE 1 and GET 1 models are a universal, high-quality

More information

2301.1 Scope: Communications and Electronic Systems addressed in this section include:

2301.1 Scope: Communications and Electronic Systems addressed in this section include: Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and

More information

TW 300 S, TW 300 CAR, HOME CLEANER

TW 300 S, TW 300 CAR, HOME CLEANER Model: HOME CLEANER TW 300 TW 300 CAR Stykliste Dansk Indholdsfortegnelse HOME CLEANER - Tube, hose and lever 3 HOME CLEANER - Nozzles and bag 5 Cabinet 7 Vac motor 9 Carpet adaptor 11 Hand adaptor 13

More information

RESERVDELSLISTA NORMFINISH DP14

RESERVDELSLISTA NORMFINISH DP14 1-A Glove L with lining 401100 1 pc 1-B Door L complete 400600 1 pc 1-C Main switch O-I 400101 1 pc 1-D START / STOP switch 400301 1 pc 1-E Fan motor 1,5 kw 400200 1 pc 1-F Gauge blast pressure 400400

More information

CUSTOMER FLOW MANAGEMENT

CUSTOMER FLOW MANAGEMENT Reduce the length of queues and ensure fair service: With Turn-O-Matic customer flow management from METO your customers are served in turn. Studies show that customers who take a number from the system

More information

Expanding a 40-Type Cabinet

Expanding a 40-Type Cabinet Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...

More information

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data

More information

BLADE S-MAX Cabinet for Blade Server

BLADE S-MAX Cabinet for Blade Server Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and

More information

Cisco Unified IP Phone Wall Mount

Cisco Unified IP Phone Wall Mount Wall Mount Components for Cisco Unified IP Phone 690, page Wall Mount Components for Cisco Unified IP Phone 69, page 4 Adjust Handset Rest, page 0 Wall Mount Components for Cisco Unified IP Phone 690 The

More information

Instortmaterialen (galva Z140) Matériaux à embétonner (galva Z140) Inlay materials (galva Z140) Code st-pp-pc RK165 RK170 RK220 RK250.

Instortmaterialen (galva Z140) Matériaux à embétonner (galva Z140) Inlay materials (galva Z140) Code st-pp-pc RK165 RK170 RK220 RK250. Instortmaterialen (galva Z40) Matériaux à embétonner (galva Z40) Inlay materials (galva Z40) RK65 RK70 RK220 RK0 Instortkanaal Conduit à embétonner Inlay duct 65-80 3m. 70-70 3m. 3m. 0-80 3m. B965 B970

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

Installation Procedure For 40mm Swept T Enclosure (Blown Fibre Cables)

Installation Procedure For 40mm Swept T Enclosure (Blown Fibre Cables) Installation Procedure For 40mm Swept T Enclosure (Blown Fibre Cables) Description Component Parts & Specialist Tools This procedure is for the installation of the 40mm Swept T enclosure when used in conjunction

More information

Installation Instructions

Installation Instructions Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001 NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)

More information

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design

More information

IT-SOLUTIONS.

IT-SOLUTIONS. IT-SOLUTIONS Well conceived Haewa Group has gained a strong profile as an innovative and competent supplier for the machinery, systems, electrical and electronic industries, well beyond European geographic

More information

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

Product Information 19 / 45HU Data-Center-Rack (Cabinet) The Rosenberger-OSI Data-Center-Rack has been developed especially for FO patch distributors in Data Centers. In Data Centers the requirement for highest density becomes increasingly more important than

More information

LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports 972-429-1963

LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports 972-429-1963 LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports 972-429-1963 Thank you for purchasing LG Motorsports products for your Gen 5 Camaro. Parts Inventory:

More information

DATA CENTER SOLUTIONS. MTP cables Patchcords Cat 6A PDU

DATA CENTER SOLUTIONS. MTP cables Patchcords Cat 6A PDU DATA CENTER SOLUTIONS MTP cables Patchcords Cat 6A PDU 1 DATA CENTER SOLUTIONS Table of contents ORBIS AS A DATA TRANSFER SUPPLIER 3 MECHANICS 4 Server and Network racks 4 PDU power bars 4 Coolers 5 Cold&Hot

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001 NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

Fiber Optic Product Catalog

Fiber Optic Product Catalog 20 is a unique fiber optic enclosure that is supplied with connectors on the front of the cassette and can be supplied with an MPO/MTP adapter or preterminated with connectors or a pigtail for splicing

More information

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers.

Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers. Document No. 79001865A RevA Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers. 1 Switch Fuse and Switch Fuse Disconnectors 1.1 Installation Instructions

More information

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs)

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) 1 MDU Construction - Objectives and Approach The MDU Construction Techniques aims at investigating the key elements of the MDU Technology

More information

4RU High Density Shelf Installation Instructions

4RU High Density Shelf Installation Instructions 4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...

More information

ZT400 Series Parts Catalog

ZT400 Series Parts Catalog Outer Casing Components 1 Control Panel ZT410 P1058930-001 1 1 Control Panel ZT420 P1058930-041 1 2 Electronics Cover ZT400 Series P1058930-003 1 3 Media Cover (includes window) ZT410 P1058930-004 1 3

More information

WIRING METHODS CHAPTER 37

WIRING METHODS CHAPTER 37 CHAPTER 37 WIRING METHODS SECTION E3701 GENERAL REQUIREMENTS E3701.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3701.2

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

STRAHLER SPOTLIGHTS PROJECTEURS CONTROL 184_185

STRAHLER SPOTLIGHTS PROJECTEURS CONTROL 184_185 184_185 mattnickel-mattschwarz nickel mat black mat nickel mat noir mat STRAHLER 1 x SDW-T, 100 W, X12-1 15872.96 FLOOD 36 15873.96 SPOT 12 mattnickel-mattschwarz nickel mat black mat nickel mat noir mat

More information

RPL-TECH CHANNEL CONVENTIONAL COLLECTION

RPL-TECH CHANNEL CONVENTIONAL COLLECTION RPL-TECH CHANNEL CONVENTIONAL COLLECTION Finials / Embouts LFN1-PT LFN1-NB LFN1-RB Note: Finials sold in pairs/ Embouts vendus à la paire LFN1-BR Finials / Embouts LFN2-BR LFN2-NB LFN2-PT LFN2-RB Note:

More information

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec, Inc. Such proprietary information and materials

More information

nr 28 nr 68 nr 4 nr 1

nr 28 nr 68 nr 4 nr 1 SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R:

More information

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008 PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008 Optec Stock #17496 for TCF-S OR IFW AND PYXIS Optec Stock #17497 for TCF-S OR IFW Optec Stock #17498 for PYXIS

More information

I/A Series HARDWARE Product Specifications. G50 Server Enclosure PSS 21H-2X50 B4 FEATURES

I/A Series HARDWARE Product Specifications. G50 Server Enclosure PSS 21H-2X50 B4 FEATURES I/A Series HARDWARE Product Specifications G50 Server Enclosure PSS 21H-2X50 B4 Note: Shown without Cable Base (Included) The I/A Series G50 Server Enclosure with front and rear access provides environmental

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

There are three possible installation kits for the MIS5022 switch. Make sure that you have the installation kit that you ordered.

There are three possible installation kits for the MIS5022 switch. Make sure that you have the installation kit that you ordered. Installation Guide Installing the Switch in the Rack There are three possible installation kits for the MIS5022 switch. Make sure that you have the installation kit that you ordered. Table 1 - Installation

More information

BX-2 Offroad # 1541002 V. 1.0 01.08.2008

BX-2 Offroad # 1541002 V. 1.0 01.08.2008 Ersatzteilliste BX-2 / List pièces de rechange BX-2/Spare parst list BX-2 Pos.-Nr.: Best. Nr.: description Déscription Bezeichnung 1 1541500 Chassis BX-2 Châssis BX-2 Chassisplatte BX-2 2 1542017 Bulkhead

More information

Beautifully Traditional

Beautifully Traditional Arcade 800mm Single Sliding Door Quadrant - nickel Arcade 900mm Single Sliding Door Quadrant - nickel ARC48 ARC49 INSTALLATION INSTRUCTIONS A www.arcadebathrooms.com IMPORTANT - Please read before installation

More information

IMPORTANT INFORMATION

IMPORTANT INFORMATION Curved Quadrant Instruction Manual CQ IMPORTANT INFORMATION Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to our guidelines.

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Line Michaud 800.363.3666 x5246 Norman Brazeau 866.351.7575 x142 www.tlsleasing.com www.tlslocation.ca Équipement à vendre: Remorques

Line Michaud 800.363.3666 x5246 Norman Brazeau 866.351.7575 x142 www.tlsleasing.com www.tlslocation.ca Équipement à vendre: Remorques Line Michaud 800.363.3666 x546 Norman Brazeau 866.351.7575 x14 3000 3004M 3005M 3014m 304M 3047 3569 3573 3590 590 59 596 598 01 641 1005 D305 D307 D3031 D3050 D305 D30 D3090 D313 D3144 D3151 D8019 D807

More information

Customized Server Cabinets

Customized Server Cabinets GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Field-Installable Fusion Splice-on Connector

Field-Installable Fusion Splice-on Connector Economical Solution for Integrated Fiber Preparation Tool Demand. Field-Installable Fusion Splice-on Connector More Cost-effective than Mechanical Connector in All Aspects PCT/KR2010/65973 The solution

More information

OVEN PARTS For Models:RBS305PDB16, RBS305PDQ16, RBS305PDT16, RBS305PDS16 (Black) (Designer White) (Biscuit) (S.Steel)

OVEN PARTS For Models:RBS305PDB16, RBS305PDQ16, RBS305PDT16, RBS305PDS16 (Black) (Designer White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC OVEN SELF CLEAN 10 04 Litho in U.S.A.(cre) 1 Part No. OVEN PARTS 1 Literature Parts LIT8300654 Installation Instructions LIT8300772 Use & Care Guide (Oven) LIT8301758 Tech

More information

Parts List. 5 Parts List

Parts List. 5 Parts List 5 Parts List PL Controls and Cables... 5-2 PL 2 Covers... 5-4 PL 3 Paper Exit and Rear Cover... 5-6 PL 4 Output Tray Assembly... 5-8 PL 5 Scanner... 5-0 PL 6 CIS Support... 5-2 PL 7 Automatic Document

More information

Is it recommended that specifiers and installers read this guide carefully and ensure that all directions are fully and clearly understood.

Is it recommended that specifiers and installers read this guide carefully and ensure that all directions are fully and clearly understood. www.electeconline.com UPreamble EZ-Cabling is a pre-terminated turnkey voice/data cabling system that enables a fast, reliable and straightforward installation of network cabling. The system comprises

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS door frames Engineered product systems INSTALLATION INSTRUCTIONS door frames MINIMALIST DOOR FRAME Fry Reglet Flush Door frames are designed for use with 3 5/8 studs with ½ drywall both sides (4 5/8 throat

More information

PORTES 05 COULISSANTES

PORTES 05 COULISSANTES 05 60 51 55 05 70 50 50 PORTES 05 COULISSANTES 53 55 50 05 51 58 50 05 60 51 55 05 53 55 50 05 70 50 50 05 51 59 50 medum Le coulssant Medum est à la fos esthétque et d un bon rapport qualté / prx. Les

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Minimum Standards for Data/Voice Infrastructure in New Building Construction UNIVERSITY OF WATERLOO Minimum Standards for Data/Voice Infrastructure in New Building Construction 12/17/2012 Offices 1. Two Work Area Outlets (WAO) on opposite walls, each with 2 jacks 2. Each WAO shall

More information

Charlevoix II. 12 x 12. 10 x 10 PRIX : 3 079 $ Included with garden sheds Porte : acier pleine Full steel door

Charlevoix II. 12 x 12. 10 x 10 PRIX : 3 079 $ Included with garden sheds Porte : acier pleine Full steel door Charlevoix II 12 x 12 10 x 10 8 x 8 : 3 409 $ : 3 079 $ : 2 929 $ 12 9 12 13 9 69 13 69 8 10 5 11 5 10 57 57 11 5 6 6 5 7 8 47 47 4 95 95 8 6 4 Plancher: épinette 2 x 6 aux 16 po, contreplaqué 5/8 Floor

More information

BIX Termination Blocks

BIX Termination Blocks Characteristics One piece unit that passes the connection through Unit is reversed after cable connection for the cross-connect field Mounting Frames are available 250-pair, in 50-pair, 300-pair and 900-pair

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

Mazda MX-5 Soft Top Installation Instructions

Mazda MX-5 Soft Top Installation Instructions Mazda MX-5 Soft Top Installation Instructions These instructions show how to replace your soft top with the frame remaining attached to the car. This requires the use of a right angled driver which is

More information

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution

More information

ADDENDUM #1 RFQ # 11-11 KPOB CABLE TERMINATION SERVICES

ADDENDUM #1 RFQ # 11-11 KPOB CABLE TERMINATION SERVICES Date Prepared: February 15, 2011 ADDENDUM #1 RFQ # 11-11 KPOB CABLE TERMINATION SERVICES Community Transit 7100 Hardeson Road Everett, WA 98203 THIS SIGNED ADDENDUM BECOMES PART OF THE CONTRACT DOCUMENTS

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

Curved Quadrant Instruction Manual

Curved Quadrant Instruction Manual Curved Quadrant Instruction Manual Consumer Guarantee - Please make sure the purchaser/end user completes and returns the Guarantee card which is enclosed with this product. Failure to validate the Guarantee

More information

InstaPATCH ZERO Solution Guide

InstaPATCH ZERO Solution Guide SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving

More information

This specification describes termination procedures of AMP Netconnect* Cat. 6 Shielded Patch Panel with AMPTRAC* application:

This specification describes termination procedures of AMP Netconnect* Cat. 6 Shielded Patch Panel with AMPTRAC* application: Application Specification 114-93001 06/May/2011 Rev E AMP Netconnect* Cat.6 Shielded Patch Panel, 24 Ports, With AMPTRAC* Application 1. SCOPE This specification describes termination procedures of AMP

More information

Data center. Edition 2008/2009. Excellence in Connectivity Solutions

Data center. Edition 2008/2009. Excellence in Connectivity Solutions Data center Edition 2008/2009 Excellence in Connectivity Solutions Data center hubersuhner.com/lisa Your partners for system solutions The HUBER+SUHNER Group is a leading global supplier of components

More information

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service

More information

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm) Wall Mount Cabinets Link IT Single Sided Wall Mount Cabinets Welded frame, reliable structure Standing or wall mounting installation Easy mounting installation 19 standard installation Removable side panels,

More information

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales Installation information METTLER TOLEDO MultiRange Floor scales / Pit scales KC300/KCS300 KC600/KCS600 KD600/KD1500 KE1500/KE3000 KES1500/KES3000 KG3000/KG6000 KN1500 Floor scales / Pit scales Contents

More information

EKU-PORTA 40 GE PORTA 40

EKU-PORTA 40 GE PORTA 40 EKU-PORTA 40 GE PORTA 40 PORTA 40 Design-Beschlag mit schlanken Laufschienen keine Technik sichtbar Designer fitting with slim running tracks invisible running system Ferrure design avec rails de roulement

More information