Multiple Solutions for Connecting Multiple Dwelling Units (MDUs)

Size: px
Start display at page:

Download "Multiple Solutions for Connecting Multiple Dwelling Units (MDUs)"

Transcription

1 Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) 1

2 MDU Construction - Objectives and Approach The MDU Construction Techniques aims at investigating the key elements of the MDU Technology Trends What are the enabling MDU Technologies? How do they differ? Architecture Needs What are the differences between various Construction Techniques? Can they meet the service and application requirements? 2

3 MDU Applications 3

4 MDU Applications High Rise MDU 4

5 MDU Applications Medium Rise MDU 5

6 MDU Applications Low Rise/Garden MDU 6

7 MDU Applications Horizontal MDU 7

8 High Rise Application Building Overview 8

9 High Rise Application Existing Structures Columns, Track System, CATV Box Columns CATV Box Columns Shops Metal Track System Shops Staircase Staircase & Elevator Staircase 9

10 High Rise Application FDH and Access ifdt Locations New or Existing Vertical Conduit Entrance into the Living Unit Riser Cable within Horizontal Concuit Wall Mount or Rapid Fiber Indoor Distribution Terminal Additional by- pass or F1 to additional MDU locations Shops/Resturants at ground floor OSP To CO FDH placed in a secure space around the staircase area. 10

11 High Rise Application ifdt Locations The Design may include splitting within the ifdt Shops at ground floor Wall Mount or Rapid Fiber Indoor Distribution Terminal Additional by- pass or F1 to additional MDU locations Shops at ground floor OSP To CO 11

12 MDU Application - Medium Rise MDU Greenfield Application Starting Assumptions Medium Rise MDU Application - 12 Floors Plus 1 Penthouse (PH) Floor Ground Floor Office Space Restaurant Floors 2-9: Eight (8) Living Units per Floor Floors 10-12: Three (3) Living Units per Floor PH Floor has Two (2) Living Units 75 Total Living Units Common Equipment Room (CER) in Basement Common Telecom Room (CTR) Every Three (3) Floors 144 fiber Indoor FDH 144 fiber Riser Cable 12 fiber and 24 fiber IDT s 12

13 Indoor FDH Indoor FDT 144f. Indoor FDH 13

14 MDU Application - Riser Conduit and the Common Telecom Room (CTR) Location: First Floor Ceiling Location: Third Floor CTR 14

15 MDU Applications Riser Fiber Techniques Indoor Fiber Distribution Terminal Floor 8 Indoor Fiber Distribution Hub Floor 7 Floor 6 Feeder Fiber ( F 1 ) Distribution Fiber ( F 2 ) Floor 5 Floor 4 Floor 3 Floor 2 Floor 1 Entrance Facilities Riser Cable Assumptions Height Between Entrance & Floors 20 ft Height Between Floors 10 ft Office Space Entrance Splice 15

16 MDU Applications Distribution and Riser Fiber Techniques Connector Methods at the FDH 16

17 MDU Applications Distribution and Riser Fiber Techniques Connector Methods at the FDH 17

18 FTTP MDU Solutions Low Rise/Garden and the Horizontal Style For the design of some properties, a Fiber Distribution Hub (FDH) may be placed in strategic locations depending on the number of living units. The FDH has a feeder cable from the street Right of Way and a distribution cable that feeds the complex. 18

19 FTTP MDU Solutions OSP Access Pull Boxes The distribution cables terminate in pull boxes throughout the property. The larger capacity cables are spliced into smaller cables that feed directly into specific buildings. The pull boxes are utilized instead of above ground pedestals to maintain aesthetics. 19

20 FTTP MDU Product Solutions Indoor/ Outdoor Architecture Outdoor Fiber Distribution Hub Indoor or Indoor/Outdoor Cable to ONT F2 20

21 FTTP MDU Solutions Outdoor Fiber Distribution Terminals The Outside Fiber Distribution Terminal (FDT) mounts on the side of the building. The fiber optic drops placed into the living units are spliced in the terminal and the terminal is grounded at this location. 21

22 FTTP MDU Solutions Additional Outdoor Fiber Distribution Terminal Examples The Outside Fiber Distribution Terminal (FDT) mounts on the side of the building. The fiber optic drops placed into the living units are spliced or connectorized in the terminal and the terminal is grounded at this location. 22

23 FTTP MDU Solutions Additional Outdoor Fiber Distribution Terminal Examples 23

24 MDU Applications OSP & Entrance Fiber Techniques 24

25 MDU Applications Low Rise or Horizontal OSP & Entrance Fiber Techniques 12-Port Outdoor Distribution Terminal 12-Port Outdoor Distribution Terminal 12F Stub from 12-Port ODT 12F Stub from 12-Port ODT 12F Stub from 12-Port ODT 48f Splice Case 12-Port Outdoor Distribution Terminal 48F Cable 48f Splice Case 25

26 ADC Confidential and Proprietary 26

27 MDU Reduced Bend Radius Fiber Innovations in Reduced Bend Radius fiber will ease bend radius challenges Ease of installation for technicians. 27

28 FTTP MDU Product Solutions Reduced Bend Radius Drop Cables Indoor Drop Cables RealFlex Med or high-rise; RBR can be used to transfer from an indoor fiber distribution terminal to each individual living unit within a building Garden or horizontal; indoor/outdoor cable used to transition from an outdoor fiber distribution terminal to each indoor living unit Greatly reduces risk to bend induced insertion loss created during installation Indoor/outdoor and riser cables are suitable for all OFNR applications; OFNP applications will require plenum cable 28

29 FTTP MDU Product Solutions Reduced Bend Radius Drop Cables Bend radius as small as 7.5 mm without changing cable characteristics Greatly reduces risk to bend induced insertion loss created during installation Rugged 5.0mm indoor/outdoor cable jacket is composed of Low-Smoke Zero- Halogen rated materials and incorporates water swellable yarns 29

30 FTTP MDU Product Solutions Drop Cable Placement Indoor Drop Cables Indoor Drops Riser-Plenum Rated 1f or 2f SC/APC Connector 3mm or 4.7mm 30

31 MDU Application - Micro-Duct Extended to the ONT Facility Box Micro-Duct from CTR v ONT RTR BB PS ONT Optical Network Termination RTR Router for Data Distribution BB APS Battery Back-up PS Power Supply Conduit to media distribution box AC Power Location: Each living unit 31

32 MDU Applications Drop Cable Techniques Living Unit WallPlate ONT Indoor Fiber Distribution Terminal Indoor Fiber Distribution Hub Floor 8 Floor 7 Floor 6 Feeder Fiber ( F 1 ) Distribution Fiber ( F 2 ) Drop Cable ( F 3 ) Floor 5 Floor 4 Floor 3 Floor 2 Floor 1 Entrance Facilities Riser Cable Assumptions Height Between Entrance & Floors 20 ft Height Between Floors 10 ft Office Space Entrance Splice 32

33 MDU Applications Drop Cable Techniques Drop Cable Location: Wall plate to be placed where the indoor ONT would be placed. 33

34 FTTP MDU Product Solutions Molding What NOT to do! 34

35 FTTP MDU Product Solutions Molding What NOT to do! 35

36 Summary Architectural and Topological Choices Driven By Type of MDU Build How to design for the CER How to design for the CTR Where to place the Active Electronics Network Efficiency is determined by Where to place the FDH/iFDTs Riser cable placement techniques Centralized vs. Distributed Architectures 36

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly

More information

Understanding and Optimizing MDU Optical Cabling Systems

Understanding and Optimizing MDU Optical Cabling Systems Understanding and Optimizing MDU Optical Cabling Systems FTTH Conference 2008 Paper T-404G John George, Director, Systems and Applications Engineering 770-314-0778 johngeorge@ofsoptics.com www.ofsoptics.com

More information

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

Multi-Dwelling Unit Fiber Deployment

Multi-Dwelling Unit Fiber Deployment Multi-Dwelling Unit Deployment Billions of dollars are spent annually delivering high speed fiber networks to Multi-Dwelling Units (MDUs) apartments, condos, and student-housing across North America. Service

More information

FTTH ARCHITECTURE WHITE PAPER SERIES

FTTH ARCHITECTURE WHITE PAPER SERIES Not all FTTH networks are built the same. Since construction and outside plant account for the majority of total network costs, getting the architecture right has a major impact on the business case. The

More information

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Discontinued. Volition. Fiber Optic Cable. 3Innovation Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125

More information

Solutions Addressing Fiber-To-The-Multi Dwelling Unit (FTTMDU) Deployment Challenges

Solutions Addressing Fiber-To-The-Multi Dwelling Unit (FTTMDU) Deployment Challenges Solutions Addressing Fiber-To-The-Multi Dwelling Unit (FTTMDU) Deployment Challenges A W h i t e P a p e r ABSTRACT Due to numerous bandwidth intensive applications, the demand for high-speed broadband

More information

SECTION O FIBER OPTICS

SECTION O FIBER OPTICS SECTION O FIBER OPTICS CONTENTS PAGE 1. GENERAL...O-2 1.1 Introduction...O-2 1.2 Definitions...O-2 1.3 Requirements...O-2 2. RUNNING, SECURING AND FIRESTOPPING FIBER OPTIC CABLE...O-3 2.1 Running Fiber

More information

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs)

Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs) Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs) Greenfield/Brownfield Renovations Table of Contents Future-Proof your Building... 1 MTS Fibre Optics Installation Guidelines... 2 MTS Fibre Optics

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

FTTX Solutions. Multiport Service Terminal (MST) and Hardened Drop Cables. Benefits:

FTTX Solutions. Multiport Service Terminal (MST) and Hardened Drop Cables. Benefits: and Hardened Drop Cables CommScope s FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability,

More information

Building Industry Consulting Services (BICS) Guide to TELUS Communications Inc. Alberta Subdivision Servicing 2011

Building Industry Consulting Services (BICS) Guide to TELUS Communications Inc. Alberta Subdivision Servicing 2011 Building Industry Consulting Services (BICS) Guide to TELUS Communications Inc. Alberta Subdivision Servicing 2011 Table of Contents 1.0 Introduction... 3 2.0 Pre Planning... 4 3.0 Required Information...

More information

FTTH Presentation and Workshop

FTTH Presentation and Workshop FTTH Presentation and Workshop Agenda Company Overview (15 min) Introduction (technology, considerations, splitter positioning, FDH concept) 15 min Distribution network (fiber optic closures) 25 min Building

More information

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity Optical LAN Solutions The Infrastructure of Tomorrow, Available Today Luca Rozzoni RCDD Business Line Manager TE Connectivity Key Terms PON - Passive Optical Network - (Carrier) Between Central Office

More information

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 BryComm, LLC -SDD-1901 Cabling Services (per pull) - Labor Only STANDARD TIME The price per cable pull represents all labor to include fishing walls, running cable through modular furniture, terminating,

More information

Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530)

Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530) The primary focus of this standard is to provide design specifications and guidance for all building facilities relating to telecommunications cabling systems and components. This standard identifies and

More information

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification. 10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage? Fiber Optic Cordage Interconnect A Furukawa Company Durable, Flexible Cordage Surpasses Industry Strength Standards for Interconnect Cables Product Description OFS Fiber Optic Interconnect Cordage offers

More information

Business Customer Demarcation Information

Business Customer Demarcation Information Building Industry Consulting Service (BICS) Business Customer Demarcation Information The intent of this document is to clearly define Communications terminology and deployment with reference to business

More information

ENGINEERING COMMITTEE Construction and Maintenance Subcommittee

ENGINEERING COMMITTEE Construction and Maintenance Subcommittee z ENGINEERING COMMITTEE Construction and Maintenance Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 87-1 2003 (formerly CMS WG6-0001) Graphic Symbols For Cable Telecommunications Part 1: HFC Symbols

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future CORDS & CABLE ASSEMBLIES Standard Simplex/Duplex Patch Cords Overview: FOCONEC supplies full series of standard simplex, duplex patch cords or pigtails, designed for interconnection or cross connection

More information

Building Telecommunications Infrastructure Requirements

Building Telecommunications Infrastructure Requirements Building Telecommunications Infrastructure Requirements This page identifies specific requirements for the design of telecommunications infrastructure for buildings at Clemson University. (Revised October,

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

UT Southwestern Medical Center Information Resources Cable Installation Standard

UT Southwestern Medical Center Information Resources Cable Installation Standard UT Southwestern Medical Center Information Resources Cable Installation Standard PART 1- GENERAL 1.01 SUMMARY A. Furnish and install wire, cable, devices, equipment, and accessories for a complete system

More information

Building a Tier 4 Data Center on a Tier 1 Budget

Building a Tier 4 Data Center on a Tier 1 Budget Building a Tier 4 Data Center on a Tier 1 Budget A Walk Through of TIA-942 Peter P. Charland III, RCDD/NTS/WD, CET RTKL Associates Inc. March 27, 2008 BICSI South Central Region Meeting Denver, CO TIA-942

More information

Intelligent Cable Management Systems

Intelligent Cable Management Systems Intelligent Cable Management Systems Bringing Practical Application Karen Pearson - Leviton Why Cable Management Matters Performance Cooling and air-handling Maintenance ANSI/TIA 569* Telecommunication

More information

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design

More information

Errata NFPA 70. Proposed 2014 Edition

Errata NFPA 70. Proposed 2014 Edition Errata NFPA 70 National Electrical Code (Report on Proposals) Reference: 12-109 (Log #1618) Panel Meeting Action Proposed 2014 Edition The National Electrical Code Technical Correlating Committee notes

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

Indoor/Outdoor Tight-Buffered Cable Lowers Installation Costs, Reduces Time, and Increases Reliability

Indoor/Outdoor Tight-Buffered Cable Lowers Installation Costs, Reduces Time, and Increases Reliability Indoor/Outdoor Tight-Buffered Cable Lowers Installation Costs, Reduces Time, and Increases Reliability Introduction Fiber optic cable that is capable of surviving the outdoor environment and meets the

More information

3M One Pass Fiber Pathway

3M One Pass Fiber Pathway The Network of Networks 3M One Pass Fiber Pathway 3M One Pass Fiber Pathway is a horizontal cable pathway and drop cable solution installed simultaneously in one pass around a hallway perimeter Ideal for

More information

DESIGN GUIDELINES. Local Area Network

DESIGN GUIDELINES. Local Area Network DESIGN GUIDELINES Local Area Network The total oversight and management responsibilities for information assurance (IA) and protection of DoDEA s critical infrastructure fall under the purview of the DoDEA

More information

BroadbandSoHo. Verizon MDU FTTP Overview. Document Description:

BroadbandSoHo. Verizon MDU FTTP Overview. Document Description: BroadbandSoHo Verizon MDU FTTP Overview Document Description: The enclosed document was created to give a basic overview of Verizon s FTTP PON, and technology terms behind there Fios product in regards

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

Design Guide For Fibre-To-The-Home (FTTH) Requirements in New Buildings. January 2013. www.etisalat.ae/ftthguides. Revision 1.0

Design Guide For Fibre-To-The-Home (FTTH) Requirements in New Buildings. January 2013. www.etisalat.ae/ftthguides. Revision 1.0 Design Guide For Fibre-To-The-Home (FTTH) Requirements in New Buildings January 203 www.etisalat.ae/ftthguides Revision.0 Table of contents Introduction 2 General telecom requirements 3 Civil requirements

More information

TRAPEZE NETWORKS EXTERNAL ANTENNA OPTIONS

TRAPEZE NETWORKS EXTERNAL ANTENNA OPTIONS TRAPEZE NETWORKS EXTERNAL ANTENNA OPTIONS 2.4 GHz BAND INDOOR / OUTDOOR 60 0 Sector 120 0 Sector 180 0 Sector 360 0 Omni ANT-1060 ANT-1120 ANT-1180 ANT-1060R ANT-1120R ANT-1180R 5 GHz BAND INDOOR / OUTDOOR

More information

Fiber Optic Cable. www.ptsupply.com marketing@ptsupply.com 800-238-7514

Fiber Optic Cable. www.ptsupply.com marketing@ptsupply.com 800-238-7514 Fiber Optic Cable Optical fibers from a choice of major cable manufacturers are available in several grades to manage the bandwidth requirements of today's voice, data and video networks. Single Mode Enhanced

More information

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS Bandwidth Requirements Push Fiber Optic Solutions Offices, Operations

More information

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS. CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update

More information

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large

More information

SECTION 27 20 00 - DATA COMMUNICATIONS. A. Complete vertical and horizontal Communication/Data Network System as indicated.

SECTION 27 20 00 - DATA COMMUNICATIONS. A. Complete vertical and horizontal Communication/Data Network System as indicated. SECTION 27 20 00 - PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities

TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities 1 TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities Beginning in January 2010 TELUS began designing new subdivisions within the Top 48 population

More information

Broadband Deployment & Connectivity

Broadband Deployment & Connectivity F ALL 2006 VOLUME 14, ISSUE 3 Broadband Deployment & Connectivity IN THIS ISSUE Deployment Fiber & WiFi Litigation Legislation Reconfiguration fiber to the premises and the node: Key Technical Issues for

More information

IRB 2600ID-15/1.85 Simple integration, high performance

IRB 2600ID-15/1.85 Simple integration, high performance Per Lowgren, Product Manager, Medium robots IRB 2600ID-15/1.85 Simple integration, high performance February 9, 2011 Slide 1 Overview of main features General purpose robot for integrated dressing solutions.

More information

MTSFB 002: 2009. Copyright 2009 Malaysian Technical Standards Forum Bhd

MTSFB 002: 2009. Copyright 2009 Malaysian Technical Standards Forum Bhd TECHNICAL STANDARD OF IN-BUILDING FIBRE CABLING FOR FIBRE-TO-THE- PREMISE MTSFB 002: 2009 Copyright 2009 Malaysian Technical Standards Forum Bhd Committee Representation The Fixed Network Infrastructure

More information

Fibre optic cables MDIC LSZH

Fibre optic cables MDIC LSZH MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

In-Building Solutions. Wired for Wireless Solution. www.commscope.com

In-Building Solutions. Wired for Wireless Solution. www.commscope.com In-Building Solutions Wired for Wireless Solution www.commscope.com Applications: Corporate Offices and Campuses Hospitals Universities Multi-tenant High-Rise Office Buildings Hotels and Casinos Local

More information

TCTC Cabling Specifications

TCTC Cabling Specifications TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,

More information

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings ANSI/TIA/EIA-606 Administration Standard for the Telecommunications Infrastructure of Commercial Buildings Distributed by NDS INFORMATION- TELECOM SYSTEM --------------------------------------------- Head

More information

Procedure for Cutting and Respooling Fiber Optic Cable

Procedure for Cutting and Respooling Fiber Optic Cable Table of Contents 1. GENERAL 1.1 Improper use of a respooler (Figure 1) can cause damage to a cable jacket or result in wavy fiber in tight buffered cables due to cable crossovers or excessive tensile

More information

Patch Cords for Data Center Applications

Patch Cords for Data Center Applications Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails

More information

SECTION 16750. TELECOMMUNICATIONS SYSTEM (Cat 6)

SECTION 16750. TELECOMMUNICATIONS SYSTEM (Cat 6) SECTION 16750 TELECOMMUNICATIONS SYSTEM (Cat 6) PART 1 - GENERAL 1.01 REQUIREMENTS A. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements, apply

More information

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager FIRE RATED WIRING What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager INTRODUCTION OBC requirements for emergency power OBC requirements for emergency power for fire alarm systems and other building

More information

2301.1 Scope: Communications and Electronic Systems addressed in this section include:

2301.1 Scope: Communications and Electronic Systems addressed in this section include: Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

Getting 802.11n Wireless into Hotel Rooms is a Snap. But it takes some unconventional thinking

Getting 802.11n Wireless into Hotel Rooms is a Snap. But it takes some unconventional thinking Getting 802.11n Wireless into Hotel Rooms is a Snap But it takes some unconventional thinking The AP 6511 802.11n Wall Plate Access Point Wireless access points have been traditionally designed to provide

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

Fiber-to-the-Home/FTTH

Fiber-to-the-Home/FTTH Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical

More information

1 Campus Cabling Systems Introduction

1 Campus Cabling Systems Introduction 1 Campus Cabling Systems Introduction This document represents the campus cable and infrastructure standards adopted and supported by the XXXX. All new construction and renovation should conform to these

More information

FIBER OPTIC CABLE PLANT DOCUMENTATION

FIBER OPTIC CABLE PLANT DOCUMENTATION C H A P T E R 13 FIBER OPTIC CABLE PLANT DOCUMENTATION JIM HAYES Documenting the fiber optic cable plant is a necessary part of the design and installation process for the fiber optic network. Documenting

More information

Specifications for Communication Cabling Distribution Systems

Specifications for Communication Cabling Distribution Systems Washington University in St. Louis Specifications for Communication Cabling Distribution Systems General Overview Listed below are the separate sub-systems of Washington University s structured cabling

More information

7.4 3M No Polish Connector

7.4 3M No Polish Connector Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector

More information

Network Management and Troubleshooting a Guide for Administrators and Users

Network Management and Troubleshooting a Guide for Administrators and Users Network Management and Troubleshooting a Guide for Administrators and Users Slide 1 Presentation Contents Network Planning and Management Network Environmental Considerations Network Troubleshooting Slide

More information

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS) NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS) Revision date 28 th January 2014 The purpose of this document is to assist Building Refurbishment and

More information

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects. FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in

More information

Passive Optical LAN Design

Passive Optical LAN Design Passive Optical LAN Design Matt Miller Principal Systems Engineer, Leidos Phone: 443.994.6456 Email: matt.miller@leidos.com Objectives After successfully completing this course, you should be able to:

More information

Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service

Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service 1 Interpretation 1.1 The Direct Fibre Access Service described in this Service Description will be available

More information

FTTP OSP Design to Maximize Coverage and Upgradeability

FTTP OSP Design to Maximize Coverage and Upgradeability FTTP OSP Design to Maximize Coverage and Upgradeability Introduction Now that FTTP technology is being deployed after years of discussion and several false starts, one has to ask, What took so long? Was

More information

ADDENDUM #1 RFQ # 11-11 KPOB CABLE TERMINATION SERVICES

ADDENDUM #1 RFQ # 11-11 KPOB CABLE TERMINATION SERVICES Date Prepared: February 15, 2011 ADDENDUM #1 RFQ # 11-11 KPOB CABLE TERMINATION SERVICES Community Transit 7100 Hardeson Road Everett, WA 98203 THIS SIGNED ADDENDUM BECOMES PART OF THE CONTRACT DOCUMENTS

More information

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various

More information

SEAGATE SOFTWARE. About Seagate Software. IBDN Success Stories Technology. Currently, Seagate Software has customers in more than 75 countries

SEAGATE SOFTWARE. About Seagate Software. IBDN Success Stories Technology. Currently, Seagate Software has customers in more than 75 countries About Seagate Software Seagate Software is an international software corporation headquartered in Scotts Valley, California. Established in 1984 as Crystal Services Inc., Seagate Software was purchased

More information

D-Series Distribution Riser Cables

D-Series Distribution Riser Cables pi 10 product information Optical Cable Company s new numbering system When you have been serving the needs of a high-tech global industry for 25 years, things can get complicated. At Optical Cable Corporation,

More information

fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com

fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com fiberopt Whirlwind Fiber Optic Solutions product guide 1-800- 733-9473 99 Ling Rd. Rochester, NY 14612 whirlwindusa. com OpticalCON DUO, QUAD and ADAPTER CABLES 1 2 OC-4-OQ-OQ-0-050 OC-2-M50-OD-SC-0-005

More information

A Brief Explanation of Some Key National Broadband Network Terminology

A Brief Explanation of Some Key National Broadband Network Terminology A Brief Explanation of Some Key National Broadband Network Terminology The NBN provides you with an optical fibre network connection, and involves the installation of active equipment into your premises.

More information

Cabling Services (price per pull)

Cabling Services (price per pull) Cabling Services (per pull) - Labor Only Price Sheet - Standard Hours 14, Cat 5 cable - installed, terminated, tested and labeled including wall plate, jack and certification report. 0-0 Feet $ 77.00 $

More information

Wall Mounted Products

Wall Mounted Products Metallic Indoor PK Termination Boxes Prysmian Part Numbers: see below Metallic PK Termination Boxes are designed for the termination, branching and distribution of fibre optic cables in telecommunication,

More information

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes November 13, 2013! Compliant Healthcare Technologies, LLC NFPA 99, 2012 Changes November 13, 2013! The standard is now a CODE!! The NFPA 99 has now been upgraded from a Standard to a Code. This will put it in the same light

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE

Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE 1. Product description The device is an external module capable of connecting Panasonic air-conditioning units into

More information

Powering the fiber information network. A White Paper from the Experts in Business-Critical Continuity

Powering the fiber information network. A White Paper from the Experts in Business-Critical Continuity Powering the fiber information network A White Paper from the Experts in Business-Critical Continuity The future of voice, data and video transmission is fiber, but electronics will still be required to

More information

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Multilift PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: ASME A17.1 ASME A18.1 CSA B613 CSA B355-09 19-m01-2015 Part No. 000790 Copyright 2015 Savaria Corporation All rights reserved. Printed

More information

FTTX Solutions FDH 3000 Cross-Connect

FTTX Solutions FDH 3000 Cross-Connect TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

Industry solutions: Broad cast

Industry solutions: Broad cast Industry solutions: Broad cast BC 2 industry solutions: Broadcast Optical Cable Corporation s broad range of Fiber Optic Broadcast Cables are specifically designed for real-time transmission of high definition

More information

Tate s Wire & Cable Solution

Tate s Wire & Cable Solution Access Floors Tate s Wire & Cable Solution A Flexible & Sustainable Management System Access Flooring to the Power of Your company will discover complete flexibility and reconfiguration capability 2 Creating

More information

Cable Installation Project

Cable Installation Project Cable Installation Project 1. Intent. It is the intent of the U.S. Court of Appeals to install Category 6 (CAT6) data cabling in the Robert F. Peckham Federal Building and United States Courthouse, 280

More information

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

More information

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk Installation Manual Hip Smart Hub (Standard BT and BT FTTP Sites) The Home Network Hub houses the Home Owner s Broadband Router and connects the hardwired network ports on that Router to three network

More information

Cabling Technologies Providing More Optical Cabling Potential in Multi-dwelling Unit Buildings

Cabling Technologies Providing More Optical Cabling Potential in Multi-dwelling Unit Buildings Cabling Technologies Providing More Optical Cabling Potential in Multi-dwelling Unit Buildings Hayato Minami, Kensei Shiraishi, Tadashi Sasaki, Kazutoshi Takamizawa, Tetsuhiro Numata, and Osamu Inoue Abstract

More information

Gigabit Passive Optical Networks

Gigabit Passive Optical Networks White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

New. Deve. Document Type. Issue Date 07/09/2015 UNCLASSIFIED. Classification

New. Deve. Document Type. Issue Date 07/09/2015 UNCLASSIFIED. Classification Building Design Guide Deve lopments New Engineering External Plant - FTTX Document Number NBN-TE-CTO-284 Document Type Guideline Author External Networks Approver (Owner) National Engineering Manager External

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

Fiber Optic Specifications

Fiber Optic Specifications Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will

More information

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.

More information