Declaration of Conformity.

Size: px
Start display at page:

Download "Declaration of Conformity."

Transcription

1 Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives: 2004/108/EC The Electromagnetic Compatibility Directive Including amendments by the CE Marking Directive 93/68/EEC The following harmonized European standards or technical specifications have been applied: EN 55022:2010 EN :2011 EN :2008 EN :2009 EN :2006+A2:2010 EN :2004+A1:2010 EN :2006 EN :2009 EN :2004 Limits and methods of measurement of radio disturbance characteristics of information technology equipment Product family standard: Immunity requirements for components of fire, intruder and social alarm systems Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <=16 A per phase and not subject to conditional connection Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Electrical fast transient/burst immunity test Surge immunity test Immunity to conducted disturbances, induced by radio-frequency fields Voltage dips, short interruptions and voltage variations immunity tests The CE Marking on the products and/or their packaging signifies that SAMSUNG TECHWIN CO., LTD. holds the reference technical file available to the European Union authorities. Place and date of issue: #42 Seongju-Dong, Changwon-Shi, Kyungsangnam-Do,Korea / November 26, 2012 Authorized Signatory: Name : Jei Soon, Kang Title : Principal Research Engineer Signature :

2

3 Page: 2 of 64 Contents 1. Applicant information Laboratory information Test system configuration Operation environment Measurement Uncertainty Description of E.U.T General information Product description Auxiliary equipments Test configuration Operating conditions Summary of test results Summary of EMI emission test results Summary of immunity test results Performance criteria Test results Conducted Emission Radiated Emission Flicker Electrostatic Discharge Radio Frequency Electromagnetic Fields Electric Fast Transient/BURST Surge Conducted Immunity Dips and Interruptions E.U.T. photographs... 55

4 Page: 3 of Applicant information Applicant: SAMSUNG TECHWIN CO., LTD. Address: #42 Seongju-Dong, Changwon-Shi, Kyungsangnam-Do, Korea Telephone: Fax: Contact name: Kang Jei Soon Manufacturer#1: SAMSUNG TECHWIN CO., LTD. Address: #42 Seongju-Dong, Changwon-Shi, Kyungsangnam-Do, Korea Telephone: Fax: Contact name: Kang Jei Soon Manufacturer#2: Address: TIANJIN SAMSUNG TECHWIN OPTO-ELECTRONIC CO., LTD No.11 Weiliu Road. Micro-Electronic Industrial Park Jingang Road Tianjin , China

5 Page: 4 of Laboratory information Address EMC compliance Ltd Sin-dong, Yeongtong-gu, Suwon-city, Gyeonggi-do, , Korea Telephone Number: Facsimile Number: FCC CAB.: KR0040 VCCI Registration No. : R-3327, G-198, C-3706, T-1849 Industry Canada Registration No. : 8035A KOLAS NO.: 231 SITE MAP Suwon city EMC compliance

6 Page: 5 of Test system configuration 3.1 Operation environment Temperature Humidity Pressure Chamber(10 m) : 20 C 28 % R.H. - Shielded room(ce) : 21 C 24 % R.H. - Shielded room(esd) : 19 C 49 % R.H kpa Test site These testing items were performed following locations; Test item Test site Conducted Emission Shielded Room Radiated Emission 10 m Chamber Harmonics current Immunity area Voltage fluctuations and flickers Immunity area Electrostatic discharge Shielded Room Radiated RF immunity Fully anechoic chamber (3 m) Electric Fast Transient/BURST Shielded Room Surge Shielded Room Conducted RF immunity Shielded Room Voltage dip/interruption Shielded Room Mains supply voltage variations Shielded Room

7 Page: 6 of Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on CISPR , the measurement uncertainty level with a 95 % confidence level was applied. Conducted emission measurement (C.L: Approx 95 %, k = 2) Shielded Room (CE#1) Shielded Room (CE#2) Shielded Room (CE#3) 9 khz ~ 150 khz: ± 3.82 db 150 khz ~ 30 MHz: ± 3.43 db 9 khz ~ 150 khz: ± 3.82 db 150 khz ~ 30 MHz: ± 3.43 db 9 khz ~ 150 khz: ± 4.00 db 150 khz ~ 30 MHz: ± 3.63 db Radiated Emission measurement (C.L: Approx 95 %, k = 2) 10 m Chamber (#F4) 10 m Chamber (#F2) 30 MHz ~ 300 MHz 300 MHz ~ MHz 3 m: db, db 10 m: db, db 3 m: db, db 10 m: db, db 1 GHz ~ 6 GHz 3 m: db, db 30 MHz ~ 300 MHz 300 MHz ~ MHz 3 m: db, db 10 m: db, db 3 m: db, db 10 m: db, db 1 GHz ~ 6 GHz 3 m: db, db Radio Frequency Electromagnetic Fields (C.L: Approx 95 %, k = 2) ± 1.82 db Disturbance power Electromagnetic Fields (C.L: Approx 95 %, k = 2) ± 3.73 db

8 Page: 7 of Description of E.U.T. 4.1 General information

9 Page: 8 of 64

10 Page: 9 of 64

11 Page: 10 of 64

12 Page: 11 of Product description Type of product Model name (Basic) PTZ CAMERA SNP-5300P Model name (Variant) - Difference - Trade name - Serial no Testing voltage Product rating Internal clock frequency Note Engineering Sample AC 24 V, PoE AC 24 V, PoE Above 108 MHz * AC/AC adaptor was not provided by the manufacturer. * PoE Switch was not provided by the manufacturer. 4.3 Auxiliary equipments Type Model / Part # Serial number Manufacturer Note PC PSLQ0K-02N005 2A046497Q TOSHIBA USB Mouse Microsoft Headset 1 MP MANIAPC Headset 2 MP MANIAPC JIG SD Card(2GB) - - Sandisk PoE Switch FS108P 1DL20C3K00541 NETGEAR AC/AC Adaptor (AC 24 V) STA Dream Electronics

13 Page: 12 of Test configuration #1- AC 24V Note * 1 Start End Cable Length Name I/O port Name I/O port Spec. (m) Power AC/AC Adaptor Power 1.5 Non-Shield - Cable 2 EUT LAN(RJ-45) Note PC LAN(RJ-45) 3.0 Non-Shield - 3 (PTZ Audio In/Out Headset 2 Audio In/Out 2.0 Non-Shield - 4 CAMERA) Alarm JIG Alarm 3.0 Non-Shield Out-door 5 SD Card SD Card SD Card Direct USB USB Mouse USB 2.0 Shield - Note PC 7 MIC &Speaker Headset 1 MIC &Speaker 2.0 Non-Shield -

14 Page: 13 of 64 #2- PoE Note * * Power supplied from PoE Switch Start End Cable Length Name I/O port Name I/O port Spec. (m) Cable 1 LAN(RJ-45) PoE Switch LAN(RJ-45) 3.0 Non-Shield - 2 EUT Audio In/Out Headset 2 Audio In/Out 2.0 Non-Shield - (PTZ 3 CAMERA) Alarm JIG Alarm 3.0 Non-Shield Out-door 4 SD Card SD Card SD Card Direct LAN(RJ-45) PoE Switch LAN(RJ-45) 3.0 Non-Shield - 6 Note PC USB USB Mouse USB 2.0 Shield - 7 MIC &Speaker Headset 1 MIC &Speaker 2.0 Non-Shield Operating conditions The EUT was configured as normal intended use. Test mode Normal operating 1 Check the web view * Note: 2 types of powers are available for the product, that are AC 24 V, PoE. Therefore, tests were performed for 2 different types of powers.

15 Page: 14 of Summary of test results 5.1 Summary of EMI emission test results Applied Test items Test method Result Conducted Emission EN 55022:2010 Complied Radiated Emission EN 55022:2010 Complied Harmonics current EN :2006+A2:2009 N/A Voltage fluctuations and flickers EN :2008 Complied 5.2 Summary of immunity test results Applied Test items Test method Result *EN :2011 Electrostatic discharge EN :2009 Complied Radiated RF immunity EN :2006+A2:2010 Complied Electric Fast Transient/BURST EN :2004+A1:2010 Complied Surge EN :2006 Complied Conducted RF immunity EN :2009 Complied Voltage dip/interruption EN :2004 Complied Mains supply voltage variations EN :2011 N/A

16 Page: 15 of Performance criteria The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3 V/m. For components of CCTV systems, where the picture is allowed at 10 V/m, providing. (a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3 V/m, any deterioration of the picture is so minor that the system could still be used; and (c) there is no observable deterioration of the picture at 1 V/m. Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as

17 Page: 16 of 64 Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U = 130 dbμv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U = 140 dbμv, providing: (a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.) (b) at U = 130 dbμv, any deterioration of the picture is so minor that the system could still be used; and (c) there in no observable deterioration of the picture at U = 120 dbμv. Voltage dip/interruption / Voltage variation There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.

18 Page: 17 of Test results 6.1 Conducted Emission Test specification Testing voltage Test facility EN 55022:2010, Class A AC 24 V, PoE Shielded room (CE#1) Date Temperature ( C) 21 C Humidity (% R.H.) 24 % R.H. Remarks Complied Limits of conducted emission measurement AC main Frequency Class A (db(μv)) Class B (db(μv)) [MHz] Quasi-peak Average Quasi-peak Average 0.15 ~ ~ 56 * 56 ~ 46* 0.5 ~ ~ *The limit decreases linearly with the logarithm of frequency. Telecommunication Frequency [MHz] Class A Voltage Limits (db(μv)) Current Limits (db(μa)) Quasi-Peak Average Quasi-Peak Average 0.15 ~ to to to to ~ Frequency [MHz] Class B Limits (db(μv)) Current Limits (db(μa)) Quasi-Peak Average Quasi-Peak Average 0.15 ~ to to to to ~ * The limits decrease linearly with the logarithm of the frequency in the range 0.15 MHz to 0.5 MHz * The current and voltage disturbance limits are derived for use with an impedance stabilization Network (ISN) which presents a common mode (asymmetric mode) impedance of 150 Ω to the telecommunication port under test (conversion factor is 20 log /I = 44 db).

19 Page: 18 of Measurement procedure The measurements were performed in a shielded room. EUT was setup as shown in photograph and placed on a non-metallic table height of 0.8 m above the reference ground plane. The rear of table was located 0.4 m to the vertical conducted plane. EUT was power through the LISN, which was bonded to the ground plane. The LISN power was filtered. Each EUT power lead, except ground (safety) lead was individually connected through a LISN to input power source. EUT signal cables that hung closer than 0.4 m to the Horizontal metal ground 0.3 m ~ 0.4 m long. The power cord was bundles in the center. All peripheral equipment was powered from a sub LISN. The LISN and ISN were positioned 0.8 m from the EUT. Peak and Average detection were used in preliminary testing and Quasi-peak and Average detections were used at final measurement. Both lines of power cord, hot and neutral, were measured Used equipments Equipment Model Serial No. Makers Next Cal. Date Used Test Receiver ESHS /009 R&S LISN ENV R&S LISN L2-16A 0000J10705 PMM - ISN T TESEQ WIRE ISN NTFM 8158 CAT5 CAT SCHWARZBECK WIRE ISN NTFM 8158 CAT3 CAT SCHWARZBECK ISN ENY R&S

20 Page: 19 of Photographs of test setup * Telecommunication #1- AC 24V #2-PoE

21 Page: 20 of Conducted emission measurement result * Telecommunication port #1- AC 24V _ LAN Port (LCL 55 db)_10 Mbps Frequency Correction Factor Quasi-peak Average Limit Reading Result Margin Limit Reading Result Margin [MHz] ISN Cable [db(μv)] [db(μv)] [db(μv)] [db] [db(μv)] [db(μv)] [db(μv)] [db] [TEL-Line]

22 Page: 21 of 64 #1- AC 24V _ LAN Port (LCL 65 db)_100 Mbps Frequency Correction Factor Quasi-peak Average Limit Reading Result Margin Limit Reading Result Margin [MHz] ISN Cable [db(μv)] [db(μv)] [db(μv)] [db] [db(μv)] [db(μv)] [db(μv)] [db] [TEL-Line]

23 Page: 22 of 64 #2- PoE _ LAN Port (LCL 55 db)_10 Mbps Frequency Correction Factor Quasi-peak Average Limit Reading Result Margin Limit Reading Result Margin [MHz] ISN Cable [db(μv)] [db(μv)] [db(μv)] [db] [db(μv)] [db(μv)] [db(μv)] [db] [TEL-Line]

24 Page: 23 of 64 #2- PoE _ LAN Port (LCL 65 db)_100 Mbps Frequency Correction Factor Quasi-peak Average Limit Reading Result Margin Limit Reading Result Margin [MHz] ISN Cable [db(μv)] [db(μv)] [db(μv)] [db] [db(μv)] [db(μv)] [db(μv)] [db] [TEL-Line]

25 Page: 24 of Radiated Emission Test specification Testing voltage Test facility Test distance EN 55022:2010, Class A AC 24 V, PoE 10 m Chamber (#F2) 10 m, 3 m Date Temperature ( C) 20 C Humidity (% R.H.) 28 % R.H. Remarks Complied Limits of radiated emission measurement Limits below 1 GHz Frequency [MHz] Class A 10 m Class B 10 m 30 ~ ~ Limits above 1 GHz Class 3 m Class 3 m Frequency Average limit Peak limit Average limit Peak limit [GHz] (db(μv/m)) (db(μv/m)) (db(μv/m)) (db(μv/m)) 1 ~ ~ Note - The lower limit applies at the transition frequency Measurement procedure The test was done at a 10 m chamber with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8 m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3 m to 0.4 m long and were hanged at a 0.4 m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.

26 Page: 25 of Used equipments Equipment Model no. Serial no. Makers Next Cal. Date Used Test Receiver ESCI R&S Bi-Log Antenna VULB SCHWARZBECK Amplifier 310N SONOMA INSTRUMENT db Attenuator 8491A HP Antenna Mast MA4000-EP 303 Innco Systems - Turn Table DT2000S-1t 079 Innco Systems - Horn ANT ETS Amplifier 8449B 3008A02343 AGILENT Spectrum Analyzer FSP R&S Sample calculation The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: Result = M.R + C.F(A.F + C.L +3 db Att A.G) M.R = Meter Reading C.F = Correction Factor A.F = Antenna Factor C.L = Cable Loss A.G= Amplifier Gain 3 db Att = 3 db Attenuator If M.R is 30 db, A.F 12 db, C.L 5 db, 3 db, A.G 35 db The result is = 15 db(μv/m)

27 Page: 26 of Photographs of test setup * 30 ~ 1 * #1- AC 24V

28 Page: 27 of 64 * #2-PoE

29 Page: 28 of 64 *1 ~6 * #1- AC 24V

30 Page: 29 of 64 * #2-PoE

31 Page: 30 of Radiated emission measurement result * Graph and Data * 30 ~ 1 (#1- AC 24V) EMC Compliance Ltd. 10m Chamber <<Radiated Emission>> Model : SNP-5300P Serial : Operator : AC Power : 24V Temp,Humidity: [db(uv/m)] 60 Standard Remark1 Remark2 Remark3 Remark4 : CISPR Pub.22 Class A 10m : : : : <CISPR 22 Class A> Limit(QP) <CE_5300P_24V> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,QP) Final Item(V,QP) 50 Level Frequency 1000 [MHz] Final Result No Frequency (P) Reading c.f Result QP QP [MHz] [db(uv)] [db(1/m)] [db(uv/m)] V H H V H H H H Limit QP [db(uv/m)] Margin Height QP [db] [cm] Angle [deg]

32 Page: 31 of 64 * 30 ~ 1 (#2- PoE) EMC Compliance Ltd. 10m Chamber <<Radiated Emission>> Model : SNP-5300P Serial : Operator : DC Power : POE Temp,Humidity: [db(uv/m)] 60 Standard Remark1 Remark2 Remark3 Remark4 : CISPR Pub.22 Class A 10m : : : : <CISPR 22 Class A> Limit(QP) <CE_5300P_POE> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,QP) Final Item(V,QP) 50 Level Frequency 1000 [MHz] Final Result No. Frequency (P) Reading c.f Result Limit QP QP QP [MHz] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] V H H H H H H H Margin QP [db] Height Angle [cm] [deg]

33 Page: 32 of 64 * 1 ~ 6 (#1- AC 24V) EMC Compliance Ltd. 10m Chamber <<Radiated Emission>> Model : SNP-5300P Serial : Operator : AC Power : 24V Temp,Humidity: [db(uv/m)] 90 Standard Remark1 Remark2 Remark3 Remark4 : CISPR Pub.22 Class A GHz 3m : : : : <KN22 A GHz 3m> Limit(AV) Limit(PK) <CE_SVSWR_24V> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,AV) Final Item(H,PK) Final Item(V,AV) Final Item(V,PK) Level Frequency [MHz] Final Result No. Frequency (P) Reading Reading c.f Result AV PK AV [MHz] [db(uv)] [db(uv)] [db(1/m)] [db(uv/m)] H H V V H Result Limit Limit PK AV PK [db(uv/m)] [db(uv/m)] [db(uv/m)] Margin AV [db] Margin PK [db] Height Angle [cm] [deg]

34 Page: 33 of 64 * 1 ~ 6 (#2- PoE) EMC Compliance Ltd. 10m Chamber <<Radiated Emission>> Model : SNP-5300P Serial : Operator : DC Power : POE Temp,Humidity: [db(uv/m)] 90 Standard Remark1 Remark2 Remark3 Remark4 : CISPR Pub.22 Class A GHz 3m : : : : <CISPR22 A GHz 3m> Limit(AV) Limit(PK) <CE_SVSWR_POE> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,AV) Final Item(H,PK) Final Item(V,AV) Final Item(V,PK) Level Frequency [MHz] Final Result No. Frequency (P) Reading AV [MHz] [db(uv)] H V V V H 37.6 Reading PK [db(uv)] c.f Result AV [db(1/m)] [db(uv/m)] Result Limit Limit PK AV PK [db(uv/m)] [db(uv/m)] [db(uv/m)] Margin AV [db] Margin PK [db] Height Angle [cm] [deg]

35 Page: 34 of Flicker Test specification EN :2008 Testing voltage 230 V, 50 (From AC/AC Adaptor) Test facility Immunity area Date Temperature( C) 21 C Remarks Complied Humidity (% R.H.) 22 % R.H. Pressure ( ) Measurement procedure EUT was connected to the power analyzer system. Measurement was performed to obtain the desired flicker parameters. The measuring time depends on which parameters are to be measured. Plt =2h Pst = 10 min Controls and automatic programs shall be set to produce the most unfavorable sequence of voltage changes, using only those combinations of controls and programs are mentioned by the manufacturer in the instruction manual Used equipments Equipment Model no. Serial no. Makers Next Cal. date Harmonics/Flicker meter 5001x-CTS C.I Used

36 Page: 35 of Photographs of test setup #1- AC 24 V

37 Page: 36 of Measurement result #1- AC 24 V

38 Page: 37 of Electrostatic Discharge Test specification EN :2009 Contact: ± 6 Air: ± 2, ± 4, ± 8 HCP: ± 2, ± 4, ± 6 VCP: ± 2, ± 4, ± 6 Test level 330 Ω / 150 Discharge impedance Number of discharge (Each polarity) Interval between discharges Contact: 10 Air: 10 HCP / VCP: 10 1s Testing voltage AC 24 V, PoE Test facility Shielded room Date Temperature( C) 19 C Remarks Complied - There was no change of operation status during above testing. Humidity (% R.H.) 49 % R.H. Pressure ( ) Measurement procedure A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8 m above the reference grounded floor. A horizontal coupling plane (HCP) was placed on the table, and Connected to the reference plane via a 470 resistor located in each end (0.5 insulating support between EUT and HCP). In both cases a vertical coupling plane(vcp) OF 0.5 X 0.5 m was located 0.1 m from the EUT s sides. The VCP was connected to the reference plane in the same matter as the HCP Used equipments Equipment Model No. Serial No. Makers Next Cal. Date ESD Tester NSG TESEQ HCP VCP Used

39 Page: 38 of Photographs of test setup #1- AC 24V #2-PoE

40 Page: 39 of Measurement result Air discharge Electrostatic Discharge (Test Point) Contact discharge #1-AC 24V, #2-PoE #1- AC 24 V, #2- PoE HCP/VCP discharge Location(EUT) HCP (All 4 sides) VCP (All 4 sides) Applied level (±) ± 2, ± 4, ± 6 Result Complied Contact discharge Location(EUT) - Applied level (±) - Result - Applied level (±) ± 2, ± 4, ± 8 Result Complied Air discharge Location(EUT) A1 Enclosure(Case)

41 Page: 40 of Radio Frequency Electromagnetic Fields Test specification EN :2006+A2:2010 Tested frequency 80 ~ 1, 1 ~ 2, 2 ~ 2.7 Test level & Modulation 1 V/m, 3 V/m, 10 V/m, 80 % Amplitude Modulation (1 ) 1 V/m, 3 V/m, 10 V/m, Pulse Modulation (1 (0.5s ON: 0.5s OFF)) Frequency Step log 1 % step Dwell time 3s Distance 3 m from EUT to tip of antenna Testing Voltage AC 24 V, PoE Test facility Fully anechoic chamber (3 m) Date Temperature( C) 20 C Remarks Complied - There was no change of operation status during above testing. Humidity (% R.H.) 21 % R.H. Pressure ( ) Measurement procedure The test was performed at 3 m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. The EUT was tested all sides, horizontal and vertical polarization.

42 Page: 41 of Used equipments Equipment Model no. Serial no. Makers Next Cal. date Power meter PM AR Power sensor PH AR Power sensor PH AR Directional coupler DC AR Directional coupler DC7144M AR Signal generator E4421B GB AGILENT Amplifier BBA R&S Amplifier 60S1G3M AR Broadband Ant. LPDA Fiber Optic Modem HI-4413P - ETS ETSLINDGREM Antenna master - - ETS - Used Photographs of test setup #1- AC 24 V

43 Page: 42 of 64 #2- PoE Measurement result #1- AC 24 V, #2- PoE Location(EUT) Front side Rear side Left side Right side Antenna polarization Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Result Complied Complied Complied Complied Complied Complied Complied Complied

44 Page: 43 of Electric Fast Transient/BURST Test specification EN :2004+A1:2010 Coupling AC 24 V Signal: Clamp Telecommunication: Clamp Test level AC 24 V: ± 1 Peak Signal: ± 1 Peak Telecommunication: ± 1 Peak Repetition frequency 100, Tr/Th = 5 / 50 Coupling time 60 s Testing Voltage AC 24 V, PoE Test facility Shielded room Date Temperature( C) 21 C Remarks Complied - There was no change of operation status during above testing. Humidity (% R.H.) 20 % R.H. Pressure ( ) Measurement procedure A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.1 m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5 m Used equipments Equipment Model No. Serial No. Makers Next Cal. date Generator UCS 500 M EM TEST Capacitive Coupling Clamp - - EM TEST - Used

45 Page: 44 of Photographs of test setup #1- AC 24 V

46 Page: 45 of 64 #2- PoE Measurement result * AC Line EFT coupling point (+) (-) Result AC 24 V +1-1 Complied EFT coupling point (+) (-) Result Alarm +1-1 Complied * Signal (AC 24 V, PoE) * Telecommunication (AC 24 V, PoE) EFT coupling point (+) (-) Result LAN(RJ-45) +1-1 Complied

47 Page: 46 of Surge Test specification EN :2006 Coupling AC 24 V: CDN Signal: CDN Test level AC 24 V: ± 0.5, ± 1 Signal: ± 0.5, ± 1 Coupling Impedance Differential mode: Ω Common mode: 10 Ω + 9 Direct Surge pulse shape Tr/Th = 1.2 / 50 Number of surge 5 Coupling time 1 min Testing Voltage AC 24 V, PoE Test facility Shielded room Date Temperature( C) 21 C Remarks Complied - There was no change of operation status during above testing. Humidity (% R.H.) 20 % R.H. Pressure ( ) Measurement procedure A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment & table top equipment, EUT was placed on a wooden table Used equipments Equipment Model No. Serial No. Makers Next Cal. date Generator UCS 500 M EM TEST CDN CNV 508 N1 V EM TEST - Used

48 Page: 47 of Photographs of test setup #1- AC 24 V

49 Page: 48 of 64 #2- PoE Measurement result * AC Line Coupling point (+) (-) Result AC 24 V + 0.5, , - 1 Complied Coupling point (+) (-) Result Alarm + 0.5, , - 1 Complied * Signal (AC 24 V, PoE)

50 Page: 49 of Conducted Immunity Test specification EN :2009 Tested frequency 0.15 ~ 100 Test level & Modulation 1 V, 3 V, 10 V, 80 % Amplitude Modulation (1 ) 1 V, 3 V, 10 V, Pulse Modulation (1 (0.5s ON: 0.5s OFF)) Frequency Step log 1 % step Coupling method AC 24 V: CDN(M2) Signal: Clamp Telecommunication: Clamp Testing Voltage AC 24 V, PoE Test facility Shielded room Date Temperature( C) 19 C Remarks Complied - There was no change of operation status during above testing. Humidity (% R.H) 49 % R.H Pressure( ) Measurement procedure A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1 m wooden table. This test were Performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 0.15 to 100. This frequency range was Modulated with 1 sine wave at 80 %. The signal generators provided the modulated frequency at a 1 % step size. The power and all network cable, I/O cables longer than 3 m length were tested.

51 Page: 50 of Used equipments Equipment Model no. Serial no. Makers Next Cal. date CS generator NSG Schaffner CDN M Schaffner CDN CDN M2/M3N EM TEST Attenuator INA Schaffner EM Clamp KEMZ Schaffner Current probe MD720 W /M6/ 0068 Schaffner - Used Photographs of test setup #1- AC 24 V

52 Page: 51 of 64 #2- PoE

53 Page: 52 of Measurement result * AC Line Coupling point Coupling method Result AC 24 V CDN(M2) Complied Coupling point Coupling method Result Alarm Clamp Complied Coupling point Coupling method Result LAN(RJ-45) Clamp Complied * Signal (AC 24 V, PoE) * Telecommunication (AC 24 V, PoE)

54 Page: 53 of Dips and Interruptions Test specification EN :2004 Number of dips 3T Duration 10 s Phase Zero crossing (0 ) Testing Voltage 230 V, 50 (From AC/AC Adaptor) Test facility Shielded room Test Date Temperature ( C) 21 C Remarks Complied Humidity (% R.H) 20 % R.H Pressure ( ) Measurement procedure The dips/interruption test is only applicable to AC mains. The dips/interruptions were applied at zero crossing Used equipments Equipment Model no. Serial no. Makers Next Cal. date Generator UCS 500 M EM TEST Used

55 Page: 54 of Photographs of test setup #1- AC 24 V Measurement result * 230 V, 50 (From AC/AC Adaptor) Test Level (%UT) Dip/Int. (%UT) Duration /Period Phase ( ) Count number Result 80 % 20% 250 Period(1) 0 3T Complied 70 % 30 % 25Period 0 3T Complied 40 % 60 % 10 Period 0 3T Complied 0 3T Note* 0% 100 % 250 Period (2) Comment: - There was no change of operation status during above testing. (250 Period (1), 25 Period, 10 Period) - The power of EUT is off during the test. After the test, EUT is getting back to normal operation. (250 Period(2)) Note*: It fully recorded using ancillary Power source equipment to content with Manufacturer`s set up manual.

56 Page: 55 of E.U.T. photographs Front View Rear View

57 Page: 56 of 64 Left View Right View

58 Page: 57 of 64 Top View Bottom View

59 Page: 58 of 64 Inside

60 Page: 59 of 64 Main Board

61 Page: 60 of 64 CCD Board

62 Page: 61 of 64 CCD SUB Board

63 Page: 62 of 64 Interface Board

64 Page: 63 of 64 Power Board

65 Page: 64 of 64 Sensor Board

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

CERTIFICATE of EMC Compliance

CERTIFICATE of EMC Compliance CERTIFICATE of EMC Compliance 9 CERTIFICATE of EMC Compliance Report No: Type of equipment: Model Name: Applicant: Address: Manufacturer#1 : Address: Manufacturer#2 : Address: Test standards : Classification

More information

EMC TEST REPORT. Complied

EMC TEST REPORT. Complied Page : 1 of 39 EMC TEST REPORT Test report No: Type of Equipment : Model Name: Variant Model Name: Applicant: Manufacturer #1: Manufacturer #2: EMC-CE-1338 CCTV CAMERA HD61X HD73X, CNB-D2750PVR, CNB-V1760PVR

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. 음 Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Digital Video Recorder SAMSUNG SRD-1656DP SAMSUNG TECHWIN CO., LTD. In accordance with the following

More information

CERTIFICATE of EMC Compliance

CERTIFICATE of EMC Compliance CERTIFICATE of EMC Compliance Type of equipment: BOX CCD CAMERA Model Name: Variant Model: MDC4220CDN MDC4120C, MDC4120CX Report No: EMC-FCC-0534 Applicant : MicroDigital,Inc Address : #206 Kolon Digital

More information

2610 Modular Measurement and Control System

2610 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2610 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND-5084RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

EN61326 EMC COMPLIANCE REPORT on the HA Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EN61326 EMC COMPLIANCE REPORT on the HA Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd Page 1 of 19 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE

More information

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 19

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 19 Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC136813 Page: 1 of 19 EMC Test Report Application No. : TB13035176 Applicant : Shenzhen Smok Technology Co., Ltd. Equipment Under Test (EUT) EUT Name

More information

Contents. Report No.: EMC-CE-4247 Page: 2 of 71. http://www.emc2000.co.kr

Contents. Report No.: EMC-CE-4247 Page: 2 of 71. http://www.emc2000.co.kr Page: 2 of 71 Contents 1. Applicant information...3 2. Laboratory information...4 3. Test system configuration...5 3.1 Operation environment...5 3.2 Measurement Uncertainty...6 4. Description of E.U.T...7

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

EMC TEST REPORT for SHANGHAI JENCO INSTRUMENTS CO., LTD. Field/Lab Dissolved Oxygen and Temperature Instrument

EMC TEST REPORT for SHANGHAI JENCO INSTRUMENTS CO., LTD. Field/Lab Dissolved Oxygen and Temperature Instrument Page 1 of 42 EMC TEST REPORT for SHANGHAI JENCO INSTRUMENTS CO., LTD Field/Lab Dissolved Oxygen and Temperature Instrument Model No.: DO210 DO200A Serial No.: E1110335-01/01 -- Prepared For: SHANGHAI JENCO

More information

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES... TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 TEST STANDARDS... 3 1.3 TEST SUMMARY... 3 1.4 TEST METHODOLOGY... 4 1.5 TEST FACILITY... 4

More information

EMC test report 130504-AU01+E02

EMC test report 130504-AU01+E02 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E02 This test report may not be copied or published in a part without the written authorization of

More information

EMC TEST REPORT. Report No.: TS EME Model No.: 37XR-A Issued Date: Jan. 12, 2009

EMC TEST REPORT. Report No.: TS EME Model No.: 37XR-A Issued Date: Jan. 12, 2009 Page 1 of 18 EMC TEST REPORT Report No.: TS08100065-EME Model No.: 37XR-A Issued Date: Jan. 12, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203

More information

FCC 47 CFR PART 15 SUBPART B

FCC 47 CFR PART 15 SUBPART B FCC 47 CFR PART 15 SUBPART B Product Type Applicant Address : Power Filter : Schneider Electric IT (China) Co., LTD : Sec A2, 3F, No. 25 building of New Zone, 30 Fute Dongsan Road, Waigaoqiao Bonded Area,

More information

APPLICATION OF VERIFICATION. for. Chongqing Xiegu Technology Co., Ltd. HF TRANSCEIVER. Model Number:X108G

APPLICATION OF VERIFICATION. for. Chongqing Xiegu Technology Co., Ltd. HF TRANSCEIVER. Model Number:X108G APPLICATION OF VERIFICATION for Chongqing Xiegu Technology Co., Ltd. HF TRANSCEIVER Model Number:X108G Prepared for: Chongqing Xiegu Technology Co., Ltd. 7-6 Incubator Building, No.256, Fangzheng Avenue,

More information

CERTIFICATE of EMC Compliance

CERTIFICATE of EMC Compliance CERTIFICATE of EMC Compliance Type of equipment: 85PIE DOME CAMERA Basic Model Name: CNB-DM1760N Variant Model Name: CNB-E1760N(DNF), CNB-DM1760N CNB-D3760N(DNF), CNB-B1760N CNB-V3760N, CNB-V4760(1)N CNB-V5760(1)N,CNB-VC1760N

More information

EMC TEST REPORT REPORT NO.:ECE R

EMC TEST REPORT REPORT NO.:ECE R EMC TEST REPORT REPORT NO.:ECE1011114R MODEL : YCM-550, YCM-550C, SW-550, SW-560, SW-550C, SW-560C, SW-510, SW-510C, SW-30M, SW-100, SW-130, YCM-560, YCM-560C, YR-516, YCM-515, YCM-512, YC-807, YR-510,

More information

-page 1 of 32- By order of Ningbo New Oriental Electric Industrial Development Co., Ltd. at Ningbo City, China

-page 1 of 32- By order of Ningbo New Oriental Electric Industrial Development Co., Ltd. at Ningbo City, China -page 1 of 32-3155306.50 EMC Test report for LED lamp Models: GU10A Series; JDRE14A Series; JDRE27A Series; GU10B Series; JDRE14B Series; JDRE27B Series; R50A E14 Series; R50B E14 Series; C37-E14 Series;

More information

FCC EMC Test Report. (Verification of Conformity) For. Electromagnetic Interference. Prepared for FINGERTEC WORLDWIDE SDN BHD.

FCC EMC Test Report. (Verification of Conformity) For. Electromagnetic Interference. Prepared for FINGERTEC WORLDWIDE SDN BHD. FCC EMC Test Report (Verification of Conformity) For Electromagnetic Interference Of Product: FINGERTEC SKADEX Trade Name: FINGERTEC Model Number: SKADEX Prepared for FINGERTEC WORLDWIDE SDN BHD. NO. 6,

More information

EMC TEST REPORT. Report No.: CE10-LIE040103E

EMC TEST REPORT. Report No.: CE10-LIE040103E EMC TEST REPORT Report No.: CE10-LIE040103E Product: LED OUTDOOR LIGHTING Model No.: Wall Washer, Projector, Underground light, Street Light, Underwater Light, Strip Light Applicant: Shenzhen Saiju Electronic

More information

EMC test report 130504-AU01+E03

EMC test report 130504-AU01+E03 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E03 This test report may not be copied or published in a part without the written authorization of

More information

A Comparison Between MIL-STD and Commercial EMC Requirements Part 1. By Vincent W. Greb President, EMC Integrity, Inc.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 1. By Vincent W. Greb President, EMC Integrity, Inc. A Comparison Between MIL-STD and Commercial EMC Requirements Part 1 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC test requirements

More information

Report No.:SZEE Page 1 of 36 EMC TEST REPORT

Report No.:SZEE Page 1 of 36 EMC TEST REPORT Report No.:SZEE090603400212 Page 1 of 36 Standards EMC TEST REPORT Product Name : LED STREET LIGHT Trade Name : Model Name : JRA1-160, JRA1-120, JRA1-90 JRA1-60, JRA1-30, JRX-Y90, JRX-Y120 Serial Number

More information

FCC EMC Test Report. (Verification of Conformity) For. Electromagnetic Interference. Prepared for FINGERTEC WORLDWIDE SDN BHD

FCC EMC Test Report. (Verification of Conformity) For. Electromagnetic Interference. Prepared for FINGERTEC WORLDWIDE SDN BHD FCC EMC Test Report (Verification of Conformity) For Electromagnetic Interference Of Product: ADAPTEC Trade Name: FINGERTEC Model Number: ADAPTEC-X Prepared for FINGERTEC WORLDWIDE SDN BHD NO. 6, 8 & 10

More information

EMC TEST REPORT. Model No.: HP-2850

EMC TEST REPORT. Model No.: HP-2850 EMC TEST REPORT For SHENZHEN LISAIER TRONICS CO., LTD. Headphone & Earphone Model No.:HP-2850 Prepared for Address Prepared by Address : SHENZHEN LISAIER TRONICS CO., LTD. : NO.22, XIHU INDUSTRIAL PARK,

More information

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail. EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of

More information

Korea Standard Testlab , Jangdeokdong-gil, Namyang-eup, Hwaseong-si, Gyeonggi-do, Korea Tel : FAX :

Korea Standard Testlab , Jangdeokdong-gil, Namyang-eup, Hwaseong-si, Gyeonggi-do, Korea Tel : FAX : TABLE OF CONTENTS Korea Standard Testlab 1.1. General Product Description... 3 1.2. Device Modification... 3 1.3. EUT Configuration(s)... 4 1.4. EUT Operating Mode(s)... 5 1.5. Configurationm of Test System...

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

FCC 47 CFR PART 15 SUBPART B

FCC 47 CFR PART 15 SUBPART B FCC 47 CFR PART 15 SUBPART B TEST REPORT For DC TO DC CONVERTER Model : E100/E100I Series Issued for MicroPower Direct, LLC 232 Tosca Drive Stoughton, MA 02072 U.S.A. Issued by Compliance Certification

More information

TEST REPORT SUBJECT CLIENT NATURE OF TEST RESULT DATE OF COMPLETION OF TESTS DATE OF ISSUE. OLPC Laptop model XO-1

TEST REPORT SUBJECT CLIENT NATURE OF TEST RESULT DATE OF COMPLETION OF TESTS DATE OF ISSUE. OLPC Laptop model XO-1 TEST REPORT 47551.2 SUBJECT OLPC Laptop model XO-1 CLIENT Name: OLPC Australia Address: 15/758 Bourke St, Surry Hills, NSW 2010, Australia Order No: Signed quote Date of Order/Letter: 9 th July 2008 Attention:

More information

EMC TEST REPORT For. : AGC Lighting Co., Ltd.

EMC TEST REPORT For. : AGC Lighting Co., Ltd. EMC TEST REPORT For AGC Lighting Co., Ltd. LED High Bay Light Model No.: HB01-90 Additional Model No.: HB01-50, HB01-70, HB01-50/T, HB01-70/T, HB01-90/T Prepared for Address : AGC Lighting Co., Ltd. :

More information

EMC Test Report For Shenzhen Lisaier Tronics Co., Ltd. Headphone and Earphone Model: See Appendix 1

EMC Test Report For Shenzhen Lisaier Tronics Co., Ltd. Headphone and Earphone Model: See Appendix 1 EMC Test Report For Shenzhen Lisaier Tronics Co., Ltd. Headphone and Earphone Model: See Appendix 1 Prepared For : Shenzhen Lisaier Tronics Co., Ltd. NO. 22, Xihu Industrial Park, Xikeng Henggang Town,

More information

QV~amQng ffti'date: April 12, 2013

QV~amQng ffti'date: April 12, 2013 BUREAU VERITAS TEST REPORT No.: (5213)095-0264 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTO I Fax: I -- Attn: -- I Email: I -- Address: Buildiinq 6, XinXinTian Industrial Park, XinSha Road, Sha.Jinq street,

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

EMC CONFORMITY TEST REPORT

EMC CONFORMITY TEST REPORT Standards EMC CONFORMITY TEST REPORT Product Name : Coin type vibrator motor Trade Name : kotl Model Number : Ф8-Ф12mm Serial Number : Not Applicable Technical Data : DC 1.3V-3V Report Number : SHEE080704310901

More information

Test Report. Applicant : ICP DAS CO., LTD. Address : No. 111, Kuang-Fu N. Rd., Hsin-Chu Industrial Park, Hukou Shiang, HSINCHU 303, Taiwan

Test Report. Applicant : ICP DAS CO., LTD. Address : No. 111, Kuang-Fu N. Rd., Hsin-Chu Industrial Park, Hukou Shiang, HSINCHU 303, Taiwan Test Report Product Name : ICPCON CPU with Converter Model No. : I-7058, I-7058D, I-7050A, I-7050AD, I7067D, I-7066D, I-7510AR, I-7017RC, I-7080D, NS-205 FCC ID. : DoC Applicant : ICP DAS CO., LTD. Address

More information

Standard(s): EN55022: A1: A2:1997 Class B. Energy Meter (AD7755) 804 Woburn Street Wilmington, MA 01887

Standard(s): EN55022: A1: A2:1997 Class B. Energy Meter (AD7755) 804 Woburn Street Wilmington, MA 01887 Standard(s): EN55022:1994 + A1:1995 + A2:1997 Class B Model(s): Energy Meter (AD7755) Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date(s) of Test: September 8, 1999 Prepared

More information

EMC REPORT VESTAX CORPORATION. Prepared For : VESTAX CORPORATION , Fukasawa, Setagaya-ku, Tokyo, , Japan

EMC REPORT VESTAX CORPORATION. Prepared For : VESTAX CORPORATION , Fukasawa, Setagaya-ku, Tokyo, , Japan Shenzhen BST Technology Co., Ltd. VESTAX CORPORATION EMC REPORT Prepared For : VESTAX CORPORATION 2-16-15, Fukasawa, Setagaya-ku, Tokyo, 158-0081, Japan Product Name: Trade Name: HEADPHONE Vestax Model

More information

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO., LTD. ISO/IEC17025 Accredited Lab. Report No: FCC File reference No:

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO., LTD. ISO/IEC17025 Accredited Lab. Report No: FCC File reference No: ISO/IEC17025 Accredited Lab. Report No: FCC1207074 File reference No: 2012-09-23 Applicant: Product: Model No: Brand Name: TBS Avionics Limited Video Transmitter TBS GREENHORN TBS Test Standards: FCC Part

More information

EMC Results Conclusion (with Justification)

EMC Results Conclusion (with Justification) EMC Results Conclusion (with Justification) RE: EMC Testing Pursuant to FCC Part 15, Subpart B Requirement Performed On The USB Mouse with Embedded Scanner, Model: Slam Basic Upon receipt of the sample

More information

Test Report /29 Humanscale FCC Report

Test Report /29 Humanscale FCC Report Test Report ------------------------------------------------------------------------------- 1/29 Humanscale FCC Report Test Report -------------------------------------------------------------------------------

More information

Global EMC Inc. Labs EMC Test Report

Global EMC Inc. Labs EMC Test Report Global EMC Inc. Labs EMC Test Report As per ICES-003:2004 & FCC Part 15 Subpart B:2006 Class A Equipment on the Ashwani Malhotra Global EMC Inc. 180 Brodie Dr, Unit 2 Richmond Hill, ON L4B 3K8 Canada Ph:

More information

LABORATORY MEASUREMENTS

LABORATORY MEASUREMENTS Page 1 of 17 LABORATORY MEASUREMENTS Pursuant To 47 CFR Part 15 Subpart B (July, 2004) And FCC Procedure ANSI C63.4 (2003) 0597 ILAC MRA Applicant: ICP DAS Co., Ltd. No. 111, Kuangfu N. Rd., Hukou Shiang,

More information

EMC TEST REPORT for Shenzhen Jeway Technology Co., Ltd.

EMC TEST REPORT for Shenzhen Jeway Technology Co., Ltd. Page 1 of 27 EMC TEST REPORT for Shenzhen Jeway Technology Co., Ltd. Headphone Model No.: JH-2190, JH-0808, JH-2205, JH-5199, JH-2208, JH-2700, JH-2601, JH-2720, JH-2117, JH-2118 Prepared for Address Prepared

More information

Reference: (\Linear Technology Corporation\EMCS81657A-EURO)

Reference: (\Linear Technology Corporation\EMCS81657A-EURO) MET Laboratories, Inc. Safety Certification - EMI - Telecom Environmental Simulation 914 WEST PATAPSCO AVENUE BALTIMORE, MARYLAND 21230-3432 PHONE (410) 354-3300 FAX (410) 354-3313 33439 WESTERN AVENUE

More information

FCC Part 15B TEST REPORT

FCC Part 15B TEST REPORT Report No. : UL15820130723FCC24-1 Page 1 of 19 FCC Part 15B TEST REPORT Product Name : GSM/GPRS Wireless Data Module Model Name : SIM800H Prepared for: Shanghai Simcom Ltd. Building A, SIM Technology Building,

More information

FCC Verification Report For a Class B Digital Device

FCC Verification Report For a Class B Digital Device FCC Verification Report For a Class B Digital Device Client: 1758 Worth Park Charlottesville, VA 22911 Phone 434-978-2888 Device Under Test: Document Number: 2009217 Reference Number: QRTL09-270 Test Results:

More information

CERTIFICATION TEST REPORT FOR DIGITAL TO ANALOG CONVERTER MODEL: MIYO FCC CLASS B COMPLIANCE DATE OF ISSUE: JULY 22, 2015 REPORT NO: R150722A

CERTIFICATION TEST REPORT FOR DIGITAL TO ANALOG CONVERTER MODEL: MIYO FCC CLASS B COMPLIANCE DATE OF ISSUE: JULY 22, 2015 REPORT NO: R150722A CERTIFICATION TEST REPORT FOR DIGITAL TO ANALOG CONVERTER MODEL: MIYO FCC CLASS B COMPLIANCE DATE OF ISSUE: JULY 22, 2015 REPORT NO: R150722A PREPARED FOR: PREPARED BY: H2 DESIGNS LLC JYOTSNA BEDI 704

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Manufacturer's Name: Honeywell Co., Ltd. Manufacturer's Address: 56, Chaam-dong, Cheonan-si, Choongcheongnam-do, 330-200, KOREA Declares that the product: Product Name: CCTV CAMERA

More information

EMC TEST REPORT For. Tea-Energy China Limited. LED Panel Lamp. Model No.: SP-6060-ND-060-WW-00. Additional Model No.: Please Refer to Page 61

EMC TEST REPORT For. Tea-Energy China Limited. LED Panel Lamp. Model No.: SP-6060-ND-060-WW-00. Additional Model No.: Please Refer to Page 61 EMC TEST REPORT For Tea-Energy China Limited LED Panel Lamp Model No.: SP-6060-ND-060-WW-00 Additional Model No.: Please Refer to Page 61 Prepared for Address : Tea-Energy China Limited : 4th Floor, 0100029

More information

FCC 47 CFR PART 15 SUBPART B & IC ICES-003 TEST REPORT. For. External USB Floppy Disk Drive

FCC 47 CFR PART 15 SUBPART B & IC ICES-003 TEST REPORT. For. External USB Floppy Disk Drive FCC 47 CFR PART 15 SUBPART B & IC ICES-003 TEST REPORT For External USB Floppy Disk Drive Trade Name / Model MOVING STAR / USBFL-BK Connectland / LECT-DISK-EXT-USB Issued to COMING DATA CO., LTD. 5F-1

More information

EN Electrical equipment for measurement, control and laboratory use. EMC requirements. - Part 1: General requirements.

EN Electrical equipment for measurement, control and laboratory use. EMC requirements. - Part 1: General requirements. Page 1 of 30 TEST REPORT EN 61326-1 Electrical equipment for measurement, control and laboratory use. EMC requirements. - Part 1: General requirements. Report Reference No.... : 55790TRFEMC Tested by (name+signature)...

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

Test Report. Applicant : D-Link Corporation Address : No. 8, Li-Hsing Seventh Road, Science-Based Industrial Park, Hsin-Chu, Taiwan, R.O.C.

Test Report. Applicant : D-Link Corporation Address : No. 8, Li-Hsing Seventh Road, Science-Based Industrial Park, Hsin-Chu, Taiwan, R.O.C. Test Report Product Name Model No. : 16/24 Port 10/100/1000 Ethernet Switch : DGS-1016TL, DGS-1024TL Applicant : D-Link Corporation Address : No. 8, Li-Hsing Seventh Road, Science-Based Industrial Park,

More information

EMC T E S T R E P O R T

EMC T E S T R E P O R T Registration No. DAT-P-207/05 EMC T E S T R E P O R T Test Report No. : E34123-00-00MH 26 March 2010 Date of issue Type / Model Name : CHT5-series Product Description : Capacitive SENSORswitch Applicant

More information

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART

More information

TEST REPORT FROM: COMMUNICATION CERTIFICATION LABORATORY TEST OF: LCU-1 & UCU-1. To EN 55022: 1998 FCC Part 15, Subpart B ICES-003

TEST REPORT FROM: COMMUNICATION CERTIFICATION LABORATORY TEST OF: LCU-1 & UCU-1. To EN 55022: 1998 FCC Part 15, Subpart B ICES-003 TEST REPORT FROM: COMMUNICATION CERTIFICATION LABORATORY TEST OF: LCU-1 & UCU-1 To EN 55022: 1998 FCC Part 15, Subpart B ICES-003 Test Report Serial No: 73-7852 TEST REPORT FROM: COMMUNICATION CERTIFICATION

More information

Report No.: 10A011501C Page 1 of 39. Test Report EN : Prepared for

Report No.: 10A011501C Page 1 of 39. Test Report EN : Prepared for Report No.: 10A011501C Page 1 of 39 EN 50121-4: 2006 Product: Ethernet Switch Device Trade Name: MOXA Model Number: EDS-608-X1; EDS-611-X1 (X1=0-9, A-Z or blank) Prepared for MOXA Inc. Fl.4, No.135, Lane

More information

EMC PRE-COMPLIANCE TEST REPORT 3SET

EMC PRE-COMPLIANCE TEST REPORT 3SET EMC PRE-COMPLIANCE TEST REPORT 3SET Date: 11.5.2013 Company: Electriel Oy Author: Tapio Pernu 1 (8) Table of contents 1. PRODUCT... 2 2. LABORATORY INFORMATION... 2 3. TEST SUMMARY... 2 3.1 Test Standards...

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

EMC COMPLIANCE REPORT In accordance with: IEC 61547: 2009 IEC : 2005 plus amendments to 2009

EMC COMPLIANCE REPORT In accordance with: IEC 61547: 2009 IEC : 2005 plus amendments to 2009 EMC Bayswater Pty Ltd 52 Holloway Drive Bayswater, Victoria, 3153, Australia Telephone: +61 3 9762 4111 Facsimile: +61 3 9762 8519 Email: sales@emcbayswater.com.au ABN: 49 112 221 333 EMC COMPLIANCE REPORT

More information

PSDC EMC LABORATORY SHARED SERVICES CENTRE EMC TEST REPORT. Test Standard: EN 55022:2010, EN :2005

PSDC EMC LABORATORY SHARED SERVICES CENTRE EMC TEST REPORT. Test Standard: EN 55022:2010, EN :2005 PSDC EMC LABORATORY SHARED SERVICES CENTRE EMC TEST REPORT Test Report Number: Date of Issue: Applicant Name: Contact Name: EMC-0757 8-January-2014 Kontron Europe GmbH Günther Dumsky Product Name: KBox

More information

EMC TEST REPORT. According to. EN 55022:2010 (Class B) EN 55024:2010 EN :2006+A1:2009+A2:2009 IEC :2008. : TRACO Electronic Ltd.

EMC TEST REPORT. According to. EN 55022:2010 (Class B) EN 55024:2010 EN :2006+A1:2009+A2:2009 IEC :2008. : TRACO Electronic Ltd. EMC TEST REPORT According to EN 55022:2010 (Class B) EN 55024:2010 EN 61000-3-2:2006+A1:2009+A2:2009 IEC 61000-4-2:2008 EN 61000-3-3:2008 IEC 61000-4-3:2006+A1:2007+A2:2010 IEC 61000-4-4:2004+A1:2010 IEC

More information

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

FCC TEST REPORT On Behalf of Fujian Newland Auto-ID Tech. Co., Ltd. Customer Information Terminal Model No.: NQuire231

FCC TEST REPORT On Behalf of Fujian Newland Auto-ID Tech. Co., Ltd. Customer Information Terminal Model No.: NQuire231 FCC TEST REPORT On Behalf of Fujian Newland Auto-ID Tech. Co., Ltd Customer Information Terminal Model No.: NQuire231 Prepared for Address : Fujian Newland Auto-ID Tech. Co., Ltd : Newland Science & Technology

More information

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :

More information

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. MODEL NUMBER: WRT54G v7 FCC ID: Q87-WT54GV70 REPORT NUMBER: 06U

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. MODEL NUMBER: WRT54G v7 FCC ID: Q87-WT54GV70 REPORT NUMBER: 06U FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR WIRELESS-G BROADBAND ROUTER WITH 4-PORT SWITCH MODEL NUMBER: WRT54G v7 FCC ID: Q87-WT54GV70 REPORT NUMBER: 06U10091-1 ISSUE DATE: FEBRUARY 21,

More information

BUREAU VERITAS. itaste-134. itaste-134

BUREAU VERITAS. itaste-134. itaste-134 BUREAU VERITAS TEST REPORT No.: (5213)211-1355 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTO I Fax: I -- Attn: -- I Email: I -- Address: Buildinq 6, XinXin Tian Industrial Park, XinSha Road, Sha.Jinq street,

More information

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EMC TEST REPORT For. Webcam. Model Number: CAM67U EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology

More information

FCC 47 CFR PART 15 SUBPART B TEST REPORT

FCC 47 CFR PART 15 SUBPART B TEST REPORT FCC 47 CFR PART 15 SUBPART B TEST REPORT for Device Configuration Backup Unit for ORing Switch/AP/AR device with DB9 connector; Device Configuration Backup Unit for ORing Switch/AP/AR device with RJ-45

More information

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF

More information

EMC test report AU02+E01

EMC test report AU02+E01 Customer: Glasstraße 1 52134 Herzogenrath Tel.: +49 2406 82-2856 Fax: +49 2406 82-2336 EMC test report 110423-AU02+E01 Quantum Glass - Saint Gobain - France The test results refer exclusively to the model

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

EMC Test Report Full Compliance Measurements

EMC Test Report Full Compliance Measurements Page 1 of 23 EMC Test Report Full Compliance Measurements Skeppshult cykel Measurements performed 2014-12-03 to 2014-12-12 R2.1 IT- 140609 Page 2 of 23 Certificate of Test Equipment Under Test Manufacturer:

More information

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian

More information

Report No. : EED32H Page 1 of 21 FCC TEST REPORT

Report No. : EED32H Page 1 of 21 FCC TEST REPORT Report No. : EED32H002546 Page 1 of 21 FCC TEST REPORT Product : IP Phone Trade mark : N/A Model/Type reference : XonTel S10P, XonTel S11P, XonTel S12P, XonTel S16P, XonTel S21P Serial Number : N/A Ratings

More information

FCC Test report for LED Panel Light Models ZY-P7-50W CDS series

FCC Test report for LED Panel Light Models ZY-P7-50W CDS series 4312774.53 FCC Test report for LED Panel Light Models ZY-P7-50W CDS series Guangzhou, date of issue: 2013-09-24 Author Ryan Liang By order of James Industry Group Co., Ltd at Hong Kong, China Author :

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

TDK-Lambda EVA2400 INDEX. * Test results are reference data based on our standard measurement condition. PAGE

TDK-Lambda EVA2400 INDEX. * Test results are reference data based on our standard measurement condition. PAGE INDEX PAGE 1. Electrostatic discharge immunity test (IEC61000-4-2) R-1 2. Radiated radio-frequency electromagnetic field immunity test (IEC61000-4-3) R-2 3. Electrical fast transient / burst immunity test

More information

EMI TEST REPORT. Report No. B080307

EMI TEST REPORT. Report No. B080307 Page 1 of 37 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 1/15 Success Street Acacia Ridge QLD 4110 Australia Telephone +61 7 3875 2455 Facsimile +61 7 3875 2466 Email brisbane@emctech.com.au EMI TEST

More information

EMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BM/ Report no: Approved by Tobias Gustavsson

EMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BM/ Report no: Approved by Tobias Gustavsson EMC TEST REPORT Oina VV AB Dispenser system Accurate speedcontrol BM/ Report no: 09006 Prepared by Ulf Heiding Approved by Tobias Gustavsson Date 2009-01-23 This report may not be reproduced other than

More information

FCC Test report for LED Panel Light Models ZY-P4-36W CDS series

FCC Test report for LED Panel Light Models ZY-P4-36W CDS series 4312774.52 FCC Test report for LED Panel Light Models ZY-P4-36W CDS series Guangzhou, date of issue: 2013-09-24 Author Ryan Liang By order of James Industry Group Co., Ltd at Hong Kong, China Author :

More information

FCC Test report for LED Panel Light Models ZY-P4-40W CDS series

FCC Test report for LED Panel Light Models ZY-P4-40W CDS series 4312774.50 FCC Test report for LED Panel Light Models ZY-P4-40W CDS series Guangzhou, date of issue: 2013-09-06 Author Ryan Liang By order of James Industry Group Co., Ltd at Hong Kong, China Author :

More information

Test Report. Applicant : WALTOP International Corp. Address : 3F, No.6-8 Du-Sing RD., Hsin-Chu Science Park, Hsin-Chu City 30078, Taiwan, R.O.C.

Test Report. Applicant : WALTOP International Corp. Address : 3F, No.6-8 Du-Sing RD., Hsin-Chu Science Park, Hsin-Chu City 30078, Taiwan, R.O.C. Test Report Product Name : Tablet: Wireless Tablet X860/X861; Dongle: Wireless Tablet Receiver X860/X861 Model No. : Tablet: RCK-T07, RCK-T07S; Dongle: RCK-T07R, RCK-T07RS FCC ID. : DoC Applicant : WALTOP

More information

The introduction of new EMC emission requirements for multimedia equipment

The introduction of new EMC emission requirements for multimedia equipment The introduction of new EMC emission requirements for multimedia equipment Mr. Kenneth Cheung, Manager Definition of MultiMedia Equipment (MME) Information technology equipment, audio equipment, video

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

FCC / Certification Test Report

FCC / Certification Test Report FCC / Certification Test Report EverPro Technologies Company Ltd. Model:EPU3HC-NNMMXYYYL REPORT# 14WB1121040F Rev 0 Prepared for: EverPro Technologies Company Ltd. 4# Guanshan Er Road, Wuhan 430073 P,R,

More information

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT

More information