Declaration of Conformity.

Size: px
Start display at page:

Download "Declaration of Conformity."

Transcription

1 Declaration of Conformity. 음 Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Digital Video Recorder SAMSUNG SRD-1656DP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives: 2004/108/EC The Electromagnetic Compatibility Directive Including amendments by the CE Marking Directive 93/68/EEC 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment (recast) The following harmonized European standards or technical specifications have been applied: EN 55022:2010 Limits and methods of measurement of radio disturbance characteristics of information technology equipment EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances EN :2011 Product family standard: Immunity requirements for components of fire, intruder and social alarm systems EN :2006+A2:2009 Limits for harmonic current emissions EN :2008 Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <=16 A per phase and not subject to conditional connection EN :2009 Electrostatic discharge immunity test EN :2006+A2:2010 Radiated, radio-frequency, electromagnetic field immunity test EN :2004+A1:2010 Electrical fast transient/burst immunity test EN :2006 Surge immunity test EN :2009 Immunity to conducted disturbances, induced by radio-frequency fields EN :2004 Voltage dips, short interruptions and voltage variations immunity tests The CE Marking on the products and/or their packaging signifies that SAMSUNG TECHWIN CO., LTD. holds the reference technical file available to the European Union authorities. Place and date of issue: Authorized Signatory: 84, Jeongdong-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, Korea / March 21, 2014 Name : Jei Soon, Kang Title : Principal Research Engineer Signature :

2

3 Page: 2 of 76 Contents 1. Applicant information Laboratory information Test system configuration Operation environment Measurement Uncertainty Description of E.U.T General information Product description Auxiliary equipments Test configuration Operating conditions Summary of test results Summary of EMI emission test results Summary of immunity test results Performance criteria Test results Conducted Emission Radiated Emission Harmonics Flicker Electrostatic Discharge Radio Frequency Electromagnetic Fields Electric Fast Transient/BURST Surge Conducted Immunity Dips and Interruptions Mains supply voltage variations E.U.T. photographs... 55

4 Page: 3 of Applicant information Applicant: Samsung Techwin Co., Ltd. Address: 84, Jeongdong-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, Korea Telephone: Fax: js2002.kang@samsung.com Contact name: Kang Jei Soon Manufacturer#1: Samsung Techwin Co., Ltd. Address: 84, Jeongdong-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, Korea Telephone: Fax: js2002.kang@samsung.com Contact name: Kang Jei Soon Manufacturer#2: Address: TIANJIN SAMSUNG TECHWIN OPTO-ELECTRONIC CO., LTD No.11 Weiliu Road. Micro-Electronic Industrial Park Jingang Road Tianjin , China

5 Page: 4 of Laboratory information Address EMC compliance Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, , Korea Telephone Number: Facsimile Number: FCC CAB.: KR0040 VCCI Registration No. : R-3327, G-198, C-3706, T-1849 Industry Canada Registration No. : 8035A KOLAS NO.: 231 SITE MAP Suwon city EMC compliance

6 Page: 5 of Test system configuration 3.1 Operation environment Temperature Humidity Pressure Chamber(10 m) : 20.3 C 29.8 % R.H. - Shielded room(ce) : 21.9 C 21.3 % R.H. - Shielded room(esd) : 21.1 C 39.6 % R.H kpa Test site These testing items were performed following locations; Test item Test site Conducted Emission Shielded Room Radiated Emission 10 m Chamber Harmonics current Immunity area Voltage fluctuations and flickers Immunity area Electrostatic discharge Shielded Room Radiated RF immunity Fully anechoic chamber (3 m) Electric Fast Transient/BURST Shielded Room Surge Shielded Room Conducted RF immunity Shielded Room Voltage dip/interruption Shielded Room Mains supply voltage variations Shielded Room

7 Page: 6 of Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on CISPR , the measurement uncertainty level with a 95 % confidence level was applied. Conducted emission measurement (C.L: Approx 95 %, k = 2) Shielded Room (CE#1) Shielded Room (CE#2) Shielded Room (CE#3) 9 khz ~ 150 khz: ± 3.82 db 150 khz ~ 30 MHz: ± 3.43 db 9 khz ~ 150 khz: ± 3.82 db 150 khz ~ 30 MHz: ± 3.43 db 9 khz ~ 150 khz: ± 4.00 db 150 khz ~ 30 MHz: ± 3.63 db Radiated Emission measurement (C.L: Approx 95 %, k = 2) 10 m Chamber (#F4) 10 m Chamber (#F2) 30 MHz ~ 300 MHz 300 MHz ~ MHz 3 m: db, db 10 m: db, db 3 m: db, db 10 m: db, db 1 GHz ~ 6 GHz 3 m: db, db 30 MHz ~ 300 MHz 300 MHz ~ MHz 3 m: db, db 10 m: db, db 3 m: db, db 10 m: db, db 1 GHz ~ 6 GHz 3 m: db, db Radio Frequency Electromagnetic Fields (C.L: Approx 95 %, k = 2) ± 1.82 db Disturbance power Electromagnetic Fields (C.L: Approx 95 %, k = 2) ± 3.73 db

8 Page: 7 of Description of E.U.T. 4.1 General information SRD-1656D Video Inputs 16 composite video Vpp, 75 ohm automatic termination Resolution 1280x480 NTSC, 1280x576 PAL / 720x480 NTSC, 720x576 PAL Live Frame rate 480fps NTSC, 400fps PAL Resolution 1280x480 NTSC, 1280x576 PAL, 704x480 NTSC, 704x576 PAL Multi Screen display 1/4/7/9/13/16/16A/PIP/Sequence Performance Operating System Embedded Linux Recording Compression Record Rate Mode H.264 NTSC: Up to 1280x480 / PAL: Up to 1280x576 NTSC: Up to 704x480 / PAL: Up to 704x576 NTSC: Up to 704x240 / PAL: Up to 704x288 NTSC: Up to 352x240 / PAL: Up to 352x288 NTSC: Manual, Schedule (Continuous/Event), Event(Pre/Post), Time lapse (1~30 fps) PAL: Manual, Schedule (Continuous/Event), Event(Pre/Post), Time lapse (1~25 fps) Event Video Loss, Motion(Level 1~10), Alarm, Tampering(Level 1~3) Overwrite modes Continuous Pre-alarm Up to 30 sec (5,10,20,30 Sec) Post-Alarm Up to 6 hour (5,10,20,30 sec,1,3,5,10,20 min,1,2,3,4,5,6 hour) Search & Playback Search mode Date/time, Event, Back up, Pos, Motion ( All Search Included Preview Function) Playback function Fast Forward/Backward (x2,x4,x8,x16,x32,x64) Backward Play with I-frame Only, Slow Forward/Backward (x1/2,x1/4,x1/8) Backward Play with I-frame Only Step Forward/Backward Network (IPv4) Transmission speed Option 1) 1280H/4CIF/2CIF/CIF(120/120/240/480fps NTSC, 100/100/200/400fps PAL) Option 2) 4CIF/2CIF/CIF(120/240/480fps NTSC, 100/200/400fps PAL) Bandwidth Up to 32Mbps Bandwidth control Selectable Stream H.264(4CIF/2CIF/CIF Selectable) Remote users Maximum Search(3)/Live Unicast(10)/Live Multicast(20) Protocol support TCP/IP,DHCP,PPPoE,SMTP,NTP,HTTP,DDNS,RTP,RTSP,SNMP Monitoring Smart viewer,web viewer, SSM(CMS) Smart phone Platform Android, ios Protocol support RTP,RTSP,HTTP,CGI,HTTPS Remote users Maximum Live(4), Search(1) Storage Internal HDD Up to 4 SATA HDDs External (e-sata Interface) Up to 2 expansion bay ( Model: SVS-5R/5E) DVD Writer (Back-up) YES USB (Back-up) 2 USB Ports File Format (Back-up) BU(DVR Player), EXE(Include Player), AVI Security Password Protection 1 Admin, 10 Group, 10 User per 1 Group Data Authentication Watermark Interface Monitors VGA 1 VGA (1280x720, 1280x1024, 1920x1080) HDMI 1 HDMI (1280x720, 1280x1024, 1920x1080) Main Composite N/A Spot(Composite) Digital Spot (2CH) Included OSD On Screen, Multi mode Support(1CH) Loop Outputs 16CH Audio Inputs/Output 16CH line in (Built in 4CH, Option : Audio Extension Cable)/ 1CH line out Compression G.711 Sampling rate 8KHz Alarm Inputs/Outputs Terminal 16 Inputs (NO/NC) / Terminal 4 relay Outputs (NO/NC), Rating : 30V DC/2A, 250V AC/0.25A Remote notification Notification via Connections Ethernet 1 RJ45 10/100/1000 Base-T Serial interface RS-232/RS-485(Full Duplex) for PTZ, Samsung System Keyboard USB USB 2.0, 2 ports e-sata 2 External SATA ports Application Supoort Protocol support Mouse, Remote Controller Samsung-E/Samsung-T/Pelco-D/Pelco-p/Panasonic/ Phillips/ AD/ DIAMOND/ ERNA/ KALATEL/ VCL PTZ Control via Coaxial Cable (Samsung CCVC, Pelco-C (Coaxitron)) General Electrical Input Voltage/Current 100 to 240 VAC ±10%; 50/60 Hz, Autoranging Power consumption Max. 60 W (with 1x HDD) Environmental Operating Temperature/Humidity +0 C to +40 C (+32 F to +104 F) / 20% to 85% RH Mechanical Dimension (W x H x D) W440 x H88 x D384.8(17.32 x 3.46 x ) Weight (With hard disks) 6.81 kg (15.01 lb) Rack mount kit 2 EA Lauguage English, French, German, Spanish, Italian, Russian, Polish, Czech, Turkish, Netherlands Portuguese, Swedish, Danish, Rumania, Serbia, Croatia, Hungary, Greek, Finnish, Norwegian, Korean, Japanese, Chinese(Traditional), Thai, Taiwanese(25 Language)

9 Page: 8 of Product description Type of product Model name (Basic) Digital Video Recorder SRD-1656DP Model name (Variant) - Difference - Trade name - Serial no Testing voltage Product rating Internal clock frequency Engineering Sample 230 V, 50 Hz V, 50/60 Hz Above 108 MHz Note Auxiliary equipments Type Model / Part # Serial number Manufacturer Monitor #1 PM24KO ZQ9XH1HBA01776V SAMSUNG Monitor #2 LT24B350 ZWP0HMCD10771M SAMSUNG Monitor #3 SMT-2231P YDQ03VDBB02500H SAMSUNG Controller SCC-1000 EW SAMSUNG Camera SCB-6000 C6PW6V3B80115Y SAMSUNG External HDD SP USB Memory(8GB) JFV33 - TRANSCEND MIC - - -

10 Page: 9 of Test configuration Note Start End Cable Length Name I/O port Name I/O port * (m) Spec. Cable 1 Power AC Main Power 1.5 Non-Shield - 2 HDMI Monitor #1 HDMI 1.0 Shield - 3 Audio Out Monitor #1 Audio In 3.0 Shield Out-door 4 D-SUB Monitor #2 D-SUB 1.5 Shield - 5 Loop Out #16 Monitor #3 Loop In 3.0 Shield Out-door 6 RS-485 Controller RS Non-Shield Out-door 7 Video In #1 Camera Video Out 3.0 Shield Out-door 8 e-sata #1 External HDD e-sata #1 1.0 Non-Shield - USB Mouse 9 USB USB 1.0 Shield - (EUT) EUT 10 USB USB Memory USB Direct - - (Digital 11 Audio In #1 MIC Audio Out 3.0 Shield Out-door Video 12 Alarm In/Out JIG Alarm In/Out 3.0 Non-Shield Out-door Recorder) 13 LAN(RJ-45) External LAN LAN(RJ-45) 3.0 Non-Shield - 14 Console Open Non-Shield - 15 Serial Open Shield - 16 e-sata #2 Open Non-Shield - 17 Audio In #2~#16 Open Shield Out-door 18 SPOT #1, #2 75 Ω Termination Shield Out-door 19 Video In #2~#16 Loop Loop Out #1~# Shield -

11 Page: 10 of Operating conditions The EUT was configured as normal intended use. Test mode Normal operating Monitoring test. Ping test. 1 Alarm In/Out test. Audio In/Out test. RS-485 test.

12 Page: 11 of Summary of test results 5.1 Summary of EMI emission test results Applied Test items Test method Result Conducted Emission EN 55022:2010 Complied Radiated Emission EN 55022:2010 Complied Harmonics current EN :2006+A2:2009 Complied Voltage fluctuations and flickers EN :2008 Complied 5.2 Summary of immunity test results Applied Test items Test method Result * EN :2011 Electrostatic discharge EN :2009 Complied Radiated RF immunity EN :2006+A2:2010 Complied Electric Fast Transient/BURST EN :2004+A1:2010 Complied Surge EN :2006 Complied Conducted RF immunity EN :2009 Complied Voltage dip/interruption EN :2004 Complied Mains supply voltage variations EN :2011 Complied

13 Page: 12 of Performance criteria The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3 V/m. For components of CCTV systems, where the picture is allowed at 10 V/m, providing. (a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3 V/m, any deterioration of the picture is so minor that the system could still be used; and (c) there is no observable deterioration of the picture at 1 V/m. Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as

14 Page: 13 of 76 Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U = 130 dbμv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U = 140 dbμv, providing: (a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.) (b) at U = 130 dbμv, any deterioration of the picture is so minor that the system could still be used; and (c) there in no observable deterioration of the picture at U = 120 dbμv. Voltage dip/interruption / Voltage variation There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.

15 Page: 14 of Test results 6.1 Conducted Emission Test specification Testing voltage Test facility EN 55022:2010, Class A 230 V, 50 Hz Shielded room (CE#1) Date Temperature ( C) 21.9 C Humidity (% R.H.) 21.3 % R.H. Remarks Complied Limits of conducted emission measurement AC main Frequency Class A (db(μv)) Class B (db(μv)) [MHz] Quasi-peak Average Quasi-peak Average 0.15 ~ ~ 56 * 56 ~ 46* 0.5 ~ ~ *The limit decreases linearly with the logarithm of frequency. Telecommunication Frequency Class A Voltage Limits (db(μv)) Current Limits (db(μa)) [MHz] Quasi-Peak Average Quasi-Peak Average 0.15 ~ to to to to ~ Frequency [MHz] Class B Limits (db(μv)) Current Limits (db(μa)) Quasi-Peak Average Quasi-Peak Average 0.15 ~ to to to to ~ * The limits decrease linearly with the logarithm of the frequency in the range 0.15 MHz to 0.5 MHz * The current and voltage disturbance limits are derived for use with an impedance stabilization Network (ISN) which presents a common mode (asymmetric mode) impedance of 150 Ω to the telecommunication port under test (conversion factor is 20 log /I = 44 db).

16 Page: 15 of Measurement procedure The measurements were performed in a shielded room. EUT was setup as shown in photograph and placed on a non-metallic table height of 0.8 m above the reference ground plane. The rear of table was located 0.4 m to the vertical conducted plane. EUT was power through the LISN, which was bonded to the ground plane. The LISN power was filtered. Each EUT power lead, except ground (safety) lead was individually connected through a LISN to input power source. EUT signal cables that hung closer than 0.4 m to the Horizontal metal ground 0.3 m ~ 0.4 m long. The power cord was bundles in the center. All peripheral equipment was powered from a sub LISN. The LISN and ISN were positioned 0.8 m from the EUT. Peak and Average detection were used in preliminary testing and Quasi-peak and Average detections were used at final measurement. Both lines of power cord, hot and neutral, were measured Used equipments Equipment Model Serial No. Makers Next Cal. Date Used Test Receiver ESCI R&S Test Receiver ESCI R&S Test Receiver ESCI R&S LISN ENV R&S LISN ESH3-Z R&S WIRE ISN NTFM 8158 CAT5 CAT SCHWARZBECK WIRE ISN NTFM 8158 CAT3 CAT SCHWARZBECK ISN ST TESEQ

17 Page: 16 of Photographs of test setup * AC Main

18 Page: 17 of 76 * Telecommunication

19 Page: 18 of Conducted emission measurement result * AC Main (SRD-1656DP) EMC Compliance.Ltd Shieldroom <<Conducted Emission>> 19 March, :54 Model : Serial : Operator : AC Power : 230V 50Hz Temp,Humidity : [db(uv)] 90 Level Standard : CISPR 22 Class A Remark1 : Remark2 : Remark3 : Remark4 : <CISPR22 A> Limit (QP) Limit (AV) <KC> Spectrum (N,AV) Spectrum (N,PK) Spectrum (L1,AV) Spectrum (L1,PK) Suspected Item(N) Suspected Item(L1) Final Item-QP(N) Final Item-AV(N) Final Item-QP(L1) Final Item-AV(L1) Frequency [MHz] Final Result --- N Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db] L1 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db]

20 Page: 19 of 76 * Telecommunication port (SRD-1656DP) LCL 65 db (LAN(RJ-45) Port) _10 Mbps EMC Compliance.Ltd Shieldroom <<Conducted Emission>> 19 March, :03 Model : Serial : Operator : AC Power : 230V 50Hz Temp,Humidity : [db(uv)] 110 Level Standard : CISPR 22 Class A Remark1 : Remark2 : Remark3 : Remark4 : <CISPR22 A_TEL> Limit (QP) Limit (AV) <CE_10_T> Spectrum (ISN-CAT5,AV Spectrum (ISN-CAT5,PK Suspected Item(ISN-CAT Final Item-QP(ISN-CAT5 Final Item-AV(ISN-CAT Frequency [MHz] Final Result --- ISN-CAT5 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db]

21 Page: 20 of 76 LCL 65 db (LAN(RJ-45) Port) _1000 Mbps EMC Compliance.Ltd Shieldroom <<Conducted Emission>> 19 March, :26 Model : Serial : Operator : AC Power : 230V 50Hz Temp,Humidity : [db(uv)] 110 Level Standard : CISPR 22 Class A Remark1 : Remark2 : Remark3 : Remark4 : <CISPR22 A_TEL> Limit (QP) Limit (AV) <CE_1000_T> Spectrum (ISN-CAT5,AV Spectrum (ISN-CAT5,PK Suspected Item(ISN-CAT Final Item-QP(ISN-CAT5 Final Item-AV(ISN-CAT Frequency [MHz] Final Result --- ISN-CAT5 Phase --- No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP CAV QP CAV QP AV QP CAV [MHz] [db(uv)] [db(uv)] [db] [db(uv)] [db(uv)] [db(uv)] [db(uv)] [db] [db]

22 Page: 21 of Radiated Emission Test specification Testing voltage Test facility Test distance EN 55022:2010, Class A 230 V, 50 Hz 10 m Chamber (#F2) 10 m, 3 m Date Temperature ( C) 20.3 C Humidity (% R.H.) 29.8 % R.H. Remarks Complied Limits of radiated emission measurement Limits below 1 GHz Frequency [MHz] Class A 10 m Class B 10 m 30 ~ ~ Limits above 1 GHz Class 3 m Class 3 m Frequency Average limit Peak limit Average limit Peak limit [GHz] (db(μv/m)) (db(μv/m)) (db(μv/m)) (db(μv/m)) 1 ~ ~ Note - The lower limit applies at the transition frequency Measurement procedure The test was done at a 10 m chamber with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8 m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3 m to 0.4 m long and were hanged at a 0.4 m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.

23 Page: 22 of Used equipments Equipment Model no. Serial no. Makers Next Cal. Date Used Test Receiver ESCI R&S Test Receiver ESCI R&S Test Receiver ESCI R&S Test Receiver ESR R&S Bi-Log Antenna VULB SCHWARZBECK Amplifier 310N SONOMA INSTRUMENT db Attenuator 8491B HP Antenna Mast MA4000-EP 303 Innco Systems - Turn Table DT2000S-1t 079 Innco Systems - Amplifier 8449B 3008A02343 AGILENT Horn ANT ETS Spectrum Analyzer FSP R&S Sample calculation The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: Result = M.R + C.F(A.F + C.L +3 db Att A.G) M.R = Meter Reading C.F = Correction Factor A.F = Antenna Factor C.L = Cable Loss A.G= Amplifier Gain 3 db Att = 3 db Attenuator If M.R is 30 db, A.F 12 db, C.L 5 db, 3 db, A.G 35 db The result is = 15 db(μv/m)

24 Page: 23 of Photographs of test setup * 30 MHz ~ 1 GHz

25 Page: 24 of 76 * 1 GHz ~ 6 GHz

26 Page: 25 of Radiated emission measurement result * Graph and Data * 30 MHz ~ 1 GHz (SRD-1656DP) EMC Compliance Ltd. 10m Chamber <<Radiated Emission>> 17 March, :36 Model : Serial : Operator : AC Power : AC 230V / 50Hz Temp,Humidity : [db(uv/m)] Standard : CISPR 22 CLASS A 10m Remark1 : Remark2 : Remark3 : Remark4 : <A> Limit(QP) <CE_RE> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,QP) Final Item(V,QP) Level Frequency [MHz] Final Result No. Frequency (P) Reading c.f Result Limit Margin Height Angle QP QP QP QP [MHz] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] [db] [cm] [deg] H V V H H H H H

27 Page: 26 of 76 * 1 GHz ~ 6 GHz (SRD-1656DP) EMC Compliance Ltd. 10m Chamber <<Radiated Emission>> 17 March, :28 Model : Serial : Operator : Power : 230V / 50Hz Temp,Humidity : [db(uv/m)] 90 Level Standard : CISPR22 CLASS A 3m Remark1 : Remark2 : Remark3 : Remark4 : <A_GHz> Limit(AV) Limit(PK) <CE_RE_G> Spectrum(H,PK) Spectrum(V,PK) Suspected Item(H) Suspected Item(V) Final Item(H,AV) Final Item(H,PK) Final Item(V,AV) Final Item(V,PK) Frequency [MHz] Final Result No. Frequency (P) Reading Reading c.f Result Result Limit Limit Margin Margin Height Angle AV PK AV PK AV PK AV PK [MHz] [db(uv)] [db(uv)] [db(1/m)] [db(uv/m)] [db(uv/m)] [db(uv/m)] [db(uv/m)] [db] [db] [cm] [deg] V H V H H V

28 Page: 27 of Harmonics Test specification Testing voltage Test facility EN :2006+A2: V, 50 Hz Immunity area Date Temperature( C) 20.4 C Humidity (% R.H.) 22.1 % R.H. Pressure (kpa) kpa Remarks Complied Measurement procedure The equipment is supplied in series with shunt(s) Rm or current transformer(s) from a source having the same nominal voltage and frequency as the rated supply voltage and frequency of the equipment. Measurements shall be made under normal load, or conditions for adequate heat discharge, and under normal operating conditions. User s operation controls or automatic programmers shall be set to produce the maximum harmonic component, for each successive harmonic component in turn. For the purpose of harmonic current limitation, equipment is classified as follows : Class A : Equipment not specified in one of the three other Classes shall be considered as Class A equipment. - Balanced three-phase equipment; - Household appliances excluding equipment identified as Class D; - Tools excluding portable tools; - Dimmers for incandescent lamps; - Audio equipment. Class B : Portable tools; Arc welding equipment which is not professional equipment. Class C : Lighting equipment. Class D : Equipment having a specified power according to less than or equal to 600 w, of the following types: - Personal computers and personal computer monitors; - Television receivers.

29 Page: 28 of Used equipments Equipment Model no. Serial no. Makers Harmonics/Flicker meter 5001x-CTS Next Cal. date C.I Used Photographs of test setup

30 Page: 29 of Measurement result

31 Page: 30 of 76

32 Page: 31 of 76

33 Page: 32 of Flicker Test specification EN :2008 Testing voltage Test facility 230 V, 50 Hz Immunity area Date Temperature( C) 20.4 C Humidity (% R.H.) 22.1 % R.H. Pressure (kpa) kpa Remarks Complied Measurement procedure EUT was connected to the power analyzer system. Measurement was performed to obtain the desired flicker parameters. The measuring time depends on which parameters are to be measured. P lt P st = 2 h = 10 min Controls and automatic programs shall be set to produce the most unfavorable sequence of voltage changes, using only those combinations of controls and programs are mentioned by the manufacturer in the instruction manual.

34 Page: 33 of Used equipments Equipment Model no. Serial no. Makers Harmonics/Flicker meter 5001x-CTS Next Cal. date C.I Used Photographs of test setup

35 Page: 34 of Measurement result

36 Page: 35 of Electrostatic Discharge Test specification EN :2009 Contact: ± 6 kv Air: ± 2 kv, ± 4 kv, ± 8 kv Test level HCP: ± 2 kv, ± 4 kv, ± 6 kv VCP: ± 2 kv, ± 4 kv, ± 6 kv Discharge impedance 330 Ω / 150 pf Number of discharge (Each polarity) Interval between discharges Testing voltage Test facility Contact: 10 Air: 10 HCP / VCP: 10 1 s 230 V, 50 Hz Shielded room Date Temperature( C) 21.1 C Humidity (% R.H.) 39.6 % R.H. Pressure (kpa) kpa Remarks Complied - There was no change of operation status during above testing Measurement procedure A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8 m above the reference grounded floor. A horizontal coupling plane (HCP) was placed on the table, and Connected to the reference plane via a 470 kω resistor located in each end (0.5 mm insulating support between EUT and HCP). In both cases a vertical coupling plane(vcp) OF 0.5 X 0.5 m was located 0.1 m from the EUT s sides. The VCP was connected to the reference plane in the same matter as the HCP.

37 Page: 36 of Used equipments Equipment Model No. Serial No. Makers Next Cal. Date Used ESD Tester PESD 1600 H HAEFELY ESD Tester NSG TESEQ HCP VCP Photographs of test setup

38 Page: 37 of Measurement result Electrostatic Discharge (Test Point) Air discharge Contact discharge

39 Page: 38 of 76

40 Page: 39 of 76 HCP/VCP discharge Location(EUT) Applied level (±) Result HCP (All 4 sides) ± 2 kv, ± 4 kv, ± 6 kv Complied VCP (All 4 sides) ± 2 kv, ± 4 kv, ± 6 kv Complied Contact discharge Location(EUT) Applied level (±) Result C1 Enclosure(Case) ± 6 kv Complied C2 Screw ± 6 kv Complied C3 USB Port ± 6 kv Complied C4 Audio In/Out Port ± 6 kv Complied C5 Video In Port ± 6 kv Complied C6 Loop Out Port ± 6 kv Complied C7 SPOT Port ± 6 kv Complied C8 Serial Port ± 6 kv Complied C9 Console Port ± 6 kv Complied C10 e-sata Port ± 6 kv Complied C11 HDMI Port ± 6 kv Complied C12 D-SUB Port ± 6 kv Complied Air discharge Location(EUT) Applied level (±) Result A1 Mouse_Enclosure(Case) ± 2 kv, ± 4 kv, ± 8 kv Complied A2 Remote Control_ Enclosure(Case) ± 2 kv, ± 4 kv, ± 8 kv Complied A3 Button ± 2 kv, ± 4 kv, ± 8 kv Complied A4 LED ± 2 kv, ± 4 kv, ± 8 kv Complied A5 Power Port ± 2 kv, ± 4 kv, ± 8 kv Complied A6 LAN(RJ-45) Port ± 2 kv, ± 4 kv, ± 8 kv Complied A7 Alram In/Out Port ± 2 kv, ± 4 kv, ± 8 kv Complied A8 RS-485 Port ± 2 kv, ± 4 kv, ± 8 kv Complied

41 Page: 40 of Radio Frequency Electromagnetic Fields Test specification Tested frequency Test level & Modulation Frequency Step Dwell time Distance Testing Voltage EN :2006+A2: MHz ~ 2.7 GHz 1 V/m, 3 V/m, 10 V/m, 80 % Amplitude Modulation (1 khz) 1 V/m, 3 V/m, 10 V/m, Pulse Modulation (1 Hz (0.5s ON: 0.5s OFF)) log 1 % step 3 s 3 m from EUT to tip of antenna 230 V, 50 Hz Test facility Fully anechoic chamber (3 m) Date Temperature( C) 21.6 C Humidity (% R.H.) 29.4 % R.H. Pressure (kpa) kpa Remarks Complied - There was no change of operation status during above testing Measurement procedure The test was performed at 3 m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. The EUT was tested all sides, horizontal and vertical polarization.

42 Page: 41 of Used equipments Equipment Model no. Serial no. Makers Next Cal. date Used Power meter PM AR Power sensor PH AR Power sensor PH AR Directional coupler DC AR Directional coupler DC7144M AR Signal generator E4421B GB AGILENT Broadband Amplifier BBA R&S Amplifier 60S1G3M AR Log Periodic Dipole Antenna LPDA ETS - Isotropic Probe HI ETS- LINDGREN Antenna master - - ETS Photographs of test setup

43 Page: 42 of Measurement result Location(EUT) Antenna polarization Result Front side Horizontal Complied Vertical Complied Rear side Horizontal Complied Vertical Complied Left side Horizontal Complied Vertical Complied Right side Horizontal Complied Vertical Complied

44 Page: 43 of Electric Fast Transient/BURST Test specification Coupling Test level Repetition frequency Coupling time Testing Voltage Test facility EN :2004+A1:2010 AC main Signal/Control: Clamp Telecommunication: Clamp AC main: ± 2 kv Peak Signal/Control: ± 1 kv Peak Telecommunication: ± 1 kv Peak 100 khz, Tr/Th = 5 / 50 ns 60 s 230 V, 50 Hz Shielded room Date Temperature( C) 21.7 C Humidity (% R.H.) 34.8 % R.H. Pressure (kpa) kpa Remarks Complied - There was no change of operation status during above testing Measurement procedure A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.1 m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5 m Used equipments Equipment Model No. Serial No. Makers Next Cal. date Used Ultra compact simulator UCS500N V EM TEST Ultra compact simulator UCS500M EM TEST Capacitive Coupling Clamp - - EM TEST

45 Page: 44 of Photographs of test setup

46 Page: 45 of Measurement result * AC main EFT coupling point (+) (-) Result L+N+PE + 2 kv - 2 kv Complied * Signal/Control EFT coupling point (+) (-) Result Alarm In/Out + 1 kv - 1 kv Complied Audio In/Out + 1 kv - 1 kv Complied RS kv - 1 kv Complied Loop Out # kv - 1 kv Complied Video In #1 + 1 kv - 1 kv Complied SPOT #1, #2 + 1 kv - 1 kv Complied * Telecommunication EFT coupling point (+) (-) Result LAN(RJ-45) + 1 kv - 1 kv Complied

47 Page: 46 of Surge Test specification EN :2006 Coupling AC main: Direct Signal/Control: Direct, CDN AC main: Differential mode: ± 0.5 kv, ± 1 kv Test level Common mode: ± 0.5 kv, ± 1 kv, ± 2 kv Coupling Impedance Surge pulse shape Signal/Control: ± 0.5 kv, ± 1 kv Differential mode: 18 μf 40 Ω μf Tr/Th = 1.2 / 50 μs Angles 0, 90, 180, 270 Number of surge 5 Common mode: 10 Ω + 9 μf Direct Coupling time Testing Voltage Test facility 1 min 230 V, 50 Hz Shielded room Date Temperature( C) 21.7 C Humidity (% R.H.) 34.8 % R.H. Pressure (kpa) kpa Remarks Complied - There was no change of operation status during above testing Measurement procedure A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment & table top equipment, EUT was placed on a wooden table Used equipments Equipment Model No. Serial No. Makers Next Cal. date Used Ultra compact simulator UCS500N V EM TEST Ultra compact simulator UCS500M EM TEST CDN CNV 508 N1 V EM TEST

48 Page: 47 of Photographs of test setup

49 Page: 48 of Measurement result * AC main Coupling point (+) (-) Result L+N kv, + 1 kv kv, - 1 kv Complied L+PE kv, + 1 kv, + 2 kv kv, - 1 kv, - 2 kv Complied N+PE kv, + 1 kv, + 2 kv kv, - 1 kv, - 2 kv Complied * Signal/Control Coupling point (+) (-) Result Alarm In/Out kv, + 1 kv kv, - 1 kv Complied Audio In/Out kv, + 1 kv kv, - 1 kv Complied RS kv, + 1 kv kv, - 1 kv Complied Loop Out # kv, + 1 kv kv, - 1 kv Complied Video In # kv, + 1 kv kv, - 1 kv Complied SPOT #1, # kv, + 1 kv kv, - 1 kv Complied

50 Page: 49 of Conducted Immunity Test specification EN :2009 Tested frequency Test level & Modulation Frequency Step Coupling method Testing Voltage Test facility 0.15 MHz ~ 100 MHz 1 V, 3 V, 10 V, 80 % Amplitude Modulation (1 khz) 1 V, 3 V, 10 V, Pulse Modulation (1 Hz (0.5s ON: 0.5s OFF)) log 1 % step AC main: CDN(M3) Signal/Control: CDN(S1/75), Clamp Telecommunication: CDN(T8-RJ45) 230 V, 50 Hz Shielded room Date Temperature( C) 24.3 C Humidity (% R.H) 33.7 % R.H Pressure(kPa) kpa Remarks Complied - There was no change of operation status during above testing Measurement procedure A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1 m wooden table. This test were Performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 0.15 MHz to 100 MHz. This frequency range was Modulated with 1 khz sine wave at 80 %. The signal generators provided the modulated frequency at a 1 % step size. The power and all network cable, I/O cables longer than 3 m length were tested.

51 Page: 50 of Used equipments Equipment Model no. Serial no. Makers Next Cal. date Used CS generator NSG Schaffner CDN M Schaffner CDN CDN M2/M3N EM TEST Attenuator INA Schaffner EM Clamp KEMZ Schaffner CDN CDN S1/ EM TEST CDN CDN-T8-RJ EM TEST Photographs of test setup

52 Page: 51 of Measurement result * AC main Coupling point Coupling method Result Power CDN(M3) Complied * Signal/Control Coupling point Coupling method Result Alarm In/Out Clamp Complied Audio In/Out Clamp Complied RS-485 Clamp Complied Loop Out #16 CDN(S1/75) Complied Video In #1 CDN(S1/75) Complied SPOT #1, #2 CDN(S1/75) Complied * Telecommunication Coupling point Coupling method Result LAN(RJ-45) CDN(T8-RJ45) Complied

53 Page: 52 of Dips and Interruptions Test specification EN :2004 Number of dips 3 T Duration 10 s Phase Zero crossing (0 ) Testing Voltage Test facility 100 V, 50 Hz / 240 V, 50 Hz Shielded room Test Date Temperature ( C) 21.7 C Humidity (% R.H.) 34.8 % R.H. Pressure (kpa) kpa Remarks Complied Measurement procedure The dips/interruption test is only applicable to AC mains. The dips/interruptions were applied at zero crossing Used equipments Equipment Model no. Serial no. Makers Next Cal. date Used Ultra compact simulator UCS500N V EM TEST Ultra compact simulator UCS500M EM TEST

54 Page: 53 of Photographs of test setup Measurement result * 100 V, 50 Hz / 240 V, 50 Hz Test Level (%UT) Dip/Int. (%UT) Duration /Period Phase ( ) Count number Result 80 % 20% 250 Period (1) 0 3T Complied 70 % 30 % 25Period 0 3T Complied 40 % 60 % 10 Period 0 3T Complied 0% 100 % 250 Period (2) 0 3T Note* Comment: - There was no change of operation status during above testing. (250 Period (1), 25Period, 10 Period) - Note* (250 Period (2) ) The power of EUT is off during the test. After the test, EUT is getting back to normal operation. It fully recorded using ancillary Power source equipment to content with Manufacturer`s set up manual.

55 Page: 54 of Mains supply voltage variations Test specification EN :2011 Supply voltage U nom + 10 %, U nom - 15 % Testing voltage 100 V, 50 Hz / 240 V, 50 Hz Test Date Temperature ( C) 21.7 C Humidity (% R.H.) 34.8 % R.H. Pressure (kpa) kpa Remarks Complied Used equipments Equipment Model no. Serial no. Makers Next Cal. date Used Ultra compact simulator UCS500N V EM TEST Ultra compact simulator UCS500M EM TEST Measurement result * 240 V, 50 Hz Comment: Supply voltage Result + 10 % 264 V Complied - 15 % 204 V Complied - There was no change of operation status during above testing. * 100 V, 50 Hz Supply voltage Result + 10 % 110 V Complied - 15 % 85 V Complied Comment: - There was no change of operation status during above testing.

56 Page: 55 of E.U.T. photographs Front View Rear View

57 Page: 56 of 76 Left View Right View

58 Page: 57 of 76 Top View Bottom View

59 Page: 58 of 76 Inside

60 Page: 59 of 76 Main Board

61 Page: 60 of 76 SUB Board

62 Page: 61 of 76 USB Board

63 Page: 62 of 76 Port Board

64 Page: 63 of 76 SATA Board

65 Page: 64 of 76 SATA DVD Board

66 Page: 65 of 76 HDD (1TB)

67 Page: 66 of 76

68 Page: 67 of 76 ODD

69 Page: 68 of 76

70 Page: 69 of 76 Power

71 Page: 70 of 76

72 Page: 71 of 76

73 Page: 72 of 76 USB Mouse

74 Page: 73 of 76

75 Page: 74 of 76 Remote Control

76 Page: 75 of 76

77 Page: 76 of 76

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND-5084RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

How To Read A Powerline From A Powerpoint Powerline To A Power Source

How To Read A Powerline From A Powerpoint Powerline To A Power Source Page: 2 of 71 Contents 1. Applicant information...3 2. Laboratory information...4 3. Test system configuration...5 3.1 Operation environment...5 3.2 Measurement Uncertainty...6 4. Description of E.U.T...7

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

A Full Range of Recording Systems

A Full Range of Recording Systems A Full Range of Recording Systems Super Vision DVR 32Ch/16Ch/9Ch Specifications High Quality Recording SVR-1660C/1645 16 Channel 480fps(N), 400fps(P) real-time recording Multi-stream support (SVR-1660C)

More information

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail. EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EMC TEST REPORT For. Webcam. Model Number: CAM67U EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian

More information

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong

More information

Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD. VS-12164U-RP Pro Hardware Spec. Processor HDD Capacity Quad Core Intel Xeon Processor E3 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility

More information

Intel Core i3-2120 processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

Intel Core i3-2120 processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD. VS-8132 Pro+ Hardware Spec. Processor HDD Capacity Intel Core i3-2120 processor 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility list,

More information

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6

More information

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z) CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),

More information

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

INTRODUCTION. -1- GV-LX4C3 Series April 24, 2012

INTRODUCTION. -1- GV-LX4C3 Series April 24, 2012 -1- INTRODUCTION The four channel GV Compact DVR V3 is a mobile video recorder, simultaneously displaying real time images from four cameras. The recording frame rate of each channel is adjustable up to

More information

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010 ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......

More information

VS-4112U-RP Pro+ Hardware Spec.

VS-4112U-RP Pro+ Hardware Spec. VS-4112U-RP Pro+ Hardware Spec. Processor Dual-core Intel processor Memory 4GB RAM HDD Capacity 4x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. For the

More information

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. 17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay -1- GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay Introduction The GV Hot Swap Backup Center System, designed for large scale video surveillance deployments, provides a secure remote backup

More information

2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please

2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please VS-2104 Pro+ Hardware Spec. Processor Memory HDD Capacity Dual-core Intel processor 4GB RAM 2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. 2. For the

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

T200, PTP/IEEE 1588 Grandmaster Clock and

T200, PTP/IEEE 1588 Grandmaster Clock and T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE

More information

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps

More information

Connect up to a total of 8 cameras from GV IP cameras (excluding GV Fisheye cameras) and third party IP cameras (of 640x 480

Connect up to a total of 8 cameras from GV IP cameras (excluding GV Fisheye cameras) and third party IP cameras (of 640x 480 - 1 - Introduction Support up to 8 units of megapixel GV IP cameras Support third party IP cameras The GV NVR System Lite is a light weight and an ultraslim GV NVR System, with which you can record video

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Recording. http://www.qnap.com/nvr/compatibilityx01.html. Smart recording (depending on the camera models)

Recording. http://www.qnap.com/nvr/compatibilityx01.html. Smart recording (depending on the camera models) VS-2108L Hardware Spec. CPU Marvell 1.6GHz DRAM 512MB DDRIII RAM Flash Memory 512MB Hard Disk Drive 2 x 3.5" SATA I/II hard disk drive (HDD) NOTE: 1. The system is shipped without hard disk drives. 2.

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

imagine Premium Security

imagine Premium Security Exceeding Every Expectation.. SVR-1650E/1640E/950E imagine Premium Security The age of premium security has arrived. Samsung Techwin is introducing a DVR that has it all ; an unbeatable performance and

More information

DS-7200HWI-SH/A Series DVR. Technical Specification

DS-7200HWI-SH/A Series DVR. Technical Specification DS-7200HWI-SH/A Series DVR Technical Specification Notices The information in this documentation is subject to change without notice and does not represent any commitment on behalf of HIKVISION. HIKVISION

More information

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical. 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: sgs_internet_operations@sgs.com

More information

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:

More information

VFS24/32HDIP. Public Display IP Monitor User Manual

VFS24/32HDIP. Public Display IP Monitor User Manual VFS24/32HDIP Public Display IP Monitor User Manual 2 Contents Before You Begin...4 Side Panel Control buttons...6 Connections...7 OSD Function...7 LCD monitor Mounting Guide...9 Getting started... 10 Power

More information

ATM Video Surveillance

ATM Video Surveillance ATM Video Surveillance with centralized video management Secure your ATMs with robust and reliable video surveillance solution Record record H.264 compressed video using less hard disk space Search search

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. 588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:

More information

Cond-IS RF Conducted Immunity System

Cond-IS RF Conducted Immunity System Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification

More information

Indoor / Outdoor Antenna

Indoor / Outdoor Antenna z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302

More information

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894 Test Report Product Name All in one PC Model No. Transmitter Module. MSI / MS-6894 MS-6633, VS12489, NetOn AP1900 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,

More information

4GB DDR3 RAM. 8 x 3.5 SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 8 x hot-swappable and lockable tray. 4 x Gigabit RJ-45 Ethernet port

4GB DDR3 RAM. 8 x 3.5 SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 8 x hot-swappable and lockable tray. 4 x Gigabit RJ-45 Ethernet port VS-8148U-RP Pro+ Hardware Spec. Processor DRAM HDD Capacity Dual Core Intel Core i3 3.3GHz Processor 4GB DDR3 RAM 8 x 3.5 SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2.

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH ENGLISH POS UNITS Installation and user guide Count, video recording and POS control unit INDEX 1 FUNCTIONALITY... 2 2 GENERAL CONSIDERATIONS... 4 3 CAMERAS INSTALLATION... 5 3.1 CAMERA TYPES... 5 3.2

More information

RAPPORTO DI PROVA / TEST REPORT

RAPPORTO DI PROVA / TEST REPORT RAPPORTO DI PROVA / TEST REPORT Rif./Ref.No. FCCTR_130738-0 Data / Date: 17/09/2013 Pagine / Pages : 15 Scopo delle prove /Test object : Richiedente / Applicant : Persona di riferimento / Applicant s referee

More information

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide UD.7L0202B1365B01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer.

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

POWERED BY. EPCOM Slim Line. Powered by Hikvision. Technical Specification

POWERED BY. EPCOM Slim Line. Powered by Hikvision. Technical Specification POWERED BY EPCOM Slim Line Powered by Hikvision Notices The information in this documentation is subject to change without notice and does not represent any commitment on behalf of HIKVISION. HIKVISION

More information

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations.

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. D. A. Weston RE02Tx.rep 14-6-2004 NARTE Certified EMC

More information

Network Video Recorder Quick Operation Guide

Network Video Recorder Quick Operation Guide Network Video Recorder Quick Operation Guide UD.6L0202B1283A01 TABLE OF CONTENTS NVR Pre-Installation... 2 NVR Installation... 2 Hard Disk Installation... 2 Front Panel... 4 Rear Panel... 5 Specifications...

More information

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

The EMI-Receiver according to CISPR 16-1-1

The EMI-Receiver according to CISPR 16-1-1 Author: Dipl. -Ing. Dieter Schwarzbeck Schwarzbeck Mess-Elektronik An der Klinge 29 D-69250 Schönau / Germany Tel.: +49 6228 1001 Fax.:+49 6228 1003 support@schwarzbeck.de www.schwarzbeck.de Requirements

More information

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com hott@ieee.org Page 2 THE BASIC

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

2.02 SPECO TECHNOLOGIES DS SERIES DIGITAL VIDEO RECORDING SYSTEM

2.02 SPECO TECHNOLOGIES DS SERIES DIGITAL VIDEO RECORDING SYSTEM D8DS/D16DS Base Model Digital Video Recorders TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 13 - SPECIAL CONSTRUCTION SECTION 137 - SECURITY CCTV SYSTEM PART 2 - PRODUCTS 2.01 GENERAL A. All equipment

More information

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18 Report No: FCC 1106180 File reference No: 2011-07-18 ISO/IEC17025Accredited Lab. Applicant: FUJIAN NAN AN BAOFENG ELECTRONICS CO., LTD Product: Model No: Trademark: Two Way Radio UV-3R BAOFENG Test Standards:

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Raptor RXi Ultra-fast scanning Countersurveillance Receiver data sheet RAPTOR RXi DATA SHEET A MATTER A MATTER OF OF NATIONAL SECURITY Raptor RXi Ultra-fast scanning Countersurveillance Receiver Features + Scans 26GHz in less than 4 seconds at 3kHz resolution (approx.

More information

Specification. Specification. 16 Based License 8 16. 1920x1080, 1280x1024, 1280x720, 1024x768 Decoding Capacity. 120fps @1080p or 240fps @720p (H.

Specification. Specification. 16 Based License 8 16. 1920x1080, 1280x1024, 1280x720, 1024x768 Decoding Capacity. 120fps @1080p or 240fps @720p (H. Specification Specification Model 2bay model Maximum Numbers of Licenses 16 Based License 8 16 Video Output HDMI, VGA Output Resolution 1920x1080, 1280x1024, 1280x720, 1024x768 Decoding Capacity 120fps

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator HTT 101 HDMI/YPbPr/S-Video/AV to DVB-T HDMI/YPbPr/S DVB Encoder Modulator TABLE OF CONTENTS 1. SPECIFICATIONS... 3 1.1 Product Overview... 3 1.2 Appearance and Description... 3 1.3 System Diagram... 4

More information

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01 RADIO TEST REPORT SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range Report Reference No.... : G0M-1206-2043-TEU440G-V01 Testing Laboratory... : Eurofins Product Service GmbH Address...

More information

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system. ENDURA - WS5050 PC WORKSTATION TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE LEVEL 3 28

More information

4-CH Hybrid Digital Video Recorder

4-CH Hybrid Digital Video Recorder 4-CH Hybrid Digital Video Recorder Key Features Hardware Embedded, highly-reliable standalone HDVR Supports 4-ch BNC connectors Supports dual local display (VGA and HDMI) Supports 3.5" SATA x 1 HDD Supports

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface

More information

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613 Report No.: 0000091428 31160742.001 Page 1 of 36 Electromagnetic Compatibility Test Report Prepared in accordance with EN 55022: 2006, +A1: 2007 On DC DC umodule Regulator LTM4613 For Linear Technology

More information

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product Information S N O. Portable VIP protection CCTV & Alarm System 2 Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to

More information

AVC792D. 4CH Full 960H DVR. Compatible with ios & Android mobile devices.

AVC792D. 4CH Full 960H DVR. Compatible with ios & Android mobile devices. AVC792D 4CH Full 960H DVR Push Status - Active Event Notification with EagleEyes App Sends instant notifications for system events, such as video loss or HDD data removal Mobile Surveillance with EagleEyes

More information

CoreNVR 16. Network Video Recorder. Recording live monitoring and playback without additional PC. Control

CoreNVR 16. Network Video Recorder. Recording live monitoring and playback without additional PC. Control CoreNVR 16 Network Video Recorder Support up to 5M resolution Up to 4MP Resolution for storage and Monitoring H.264 Video Codec High Resolution Local Display Auto Search and Insert AirLive IP Cameras Up

More information

认 证 之 家 http://www.ait0769.com

认 证 之 家 http://www.ait0769.com 认 证 之 家 http://www.ait0769.com EUROPEAN STANDARD EN 55022 NORME EUROPÉENNE EUROPÄISCHE NORM September 2006 ICS 33.100.10 Supersedes EN 55022:1998 + A1:2000 + A2:2003 English version Information technology

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition

More information

AXIS 262+ Network Video Recorder

AXIS 262+ Network Video Recorder 31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,

More information

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers AMIS Automated Metering and Information System TD-3530/TACU30 Third-Party Device Gateway Integration of meters from other manufacturers Connection and integration of max. 3 meters from third party manufactureres

More information

CoreNVR 9. 9-Channel Network Video Recorder with HDMI. Recording live monitoring and playback without additional PC

CoreNVR 9. 9-Channel Network Video Recorder with HDMI. Recording live monitoring and playback without additional PC CoreNVR 9 9-Channel Network Video Recorder with HDMI Support up to 5MP IP cameras H.264 Video Codec HDMI/VGA Video Output Auto Search and Insert AirLive IP Cameras Up to 3TB x two internal HDD plus e-sata

More information