3CJ2 Switch-Disconnectors. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG
|
|
- Cameron Wade
- 7 years ago
- Views:
Transcription
1 CJ Switch-Disconnectors Medium-Voltage Equipment Selection and Ordering Data Catalog HG Answers for energy.
2 CJ Switch-Disconnectors R-HG1-09.tif Siemens HG
3 CJ Switch-Disconnectors Contents Contents Page CJ Switch-Disconnectors Medium-Voltage Equipment Catalog HG Description General Construction and mode of operation Construction and mode of operation, standards Ambient conditions, dielectric strength and product range overview Invalid: Catalog HG 1 199, Part Equipment Selection Ordering data and configuration example Selection of basic type, switch-disconnector Selection of operating mechanism and built-on components 14 Additional equipment 1 Accessories and spare parts 17 Technical Data Electrical data, dimensions and weights Circuit diagrams 19 0 Data of built-on components 4 Annex Inquiry form Configuration instructions Configuration aid 5 7 Foldout page 4 Siemens HG
4 CJ Switch-Disconnectors R-HG11-17.tif 4 Siemens HG
5 CJ Switch-Disconnectors Description Contents Contents Description General Page 5 1 Construction and mode of operation: Construction 7 Arc-extinguishing medium 7 Arc-extinguishing process 7 Switching process 8 Operating mechanism 8 Fuse assembly 8 Make-proof earthing switch 8 Shunt release 9 Auxiliary switch 9 Industrial application: Refinery R-HG tif Spherical joint mechanism Standards Ambient conditions Dielectric strength 10 Product range overview 10 Siemens HG
6 Description General CJ Switch-Disconnectors CJ switch-disconnector The Loadable 1 Switch-disconnectors combine the functions of a switch with the establishment of an isolating distance (disconnector), and are therefore used for breaking load currents up to their rated normal current. CJ The Sudden R-HG1-00.tif R-HG1-01.tif The medium-voltage switch-disconnector CJ is designed according to the clear disconnector principle. Proven hard-gas flat arcing chambers provide a higher switching capacity than that of its competitors. Simple blade contacts and a torsion-bar spring-operated mechanism increase its making capacity and the mechanical endurance. While connecting consumers, making on an existing shortcircuit cannot be excluded. That is why, today, switchdisconnectors generally feature a short-circuit making capacity. In combination with fuses, switch-disconnectors can also be used to break short-circuit currents. The short-circuit current is interrupted by the fuses. Subsequently, the fuses trip the three poles of the switch-disconnector, disconnecting the faulty feeder from the power system. Siemens HG
7 CJ Switch-Disconnectors Description Construction and mode of operation Construction A welded base frame (1) carries the disconnector arrangement () and the flat arcing chambers (). Furthermore it contains the spring-operated mechanism (high-speed closing and high-speed opening), or the stored-energy mechanism (storage of high-speed closing/opening, manual tripping and free tripping). Optionally, the switch-disconnector can also be equipped with a make-proof earthing switch (4) or a fuse assembly. Switch-disconnectors are supplied according to category A (0 breaking operations at rated current). A special version with category B (100 breaking operations at rated current) is possible. The CJ can be wall-mounted with the isolating contact side upwards or downwards, as well as on the floor or on the ceiling in inverted position. For wall mounting, the preferred mounting position is with the isolating contact side upwards. R-HG1-0.eps 4 Switch-disconnector with make-proof earthing switch 1 Base frame Flat arcing chamber Disconnector arrangement 4 Make-proof earthing switch A Arc-extinguishing medium In switch-disconnectors, the arc is not extinguished in a vacuum interrupter, but they operate according to the principle of a hard-gas switch. This means that the arc splits off some gas from an insulating material which surrounds the arc closely, and this gas quenches the arc fast and effectively. As the material providing the gas cannot regenerate itself, the number of operating cycles is lower than that of the vacuum interrupters. Nevertheless, switch-disconnectors according to the hard-gas principle are the most frequently used ones, as they have a good cost/performance relationship. Arc-extinguishing process CJ switch-disconnectors operate with a flat hard-gas arcing chamber (). A: Switch in closed position. B HG1-117a eps HG1-118a eps B: During the opening movement, the contact blade (5) is separated first. As the auxiliary contact blade () guided in the arcing chamber is still touching, the current now flows through the auxiliary contact blade. C: When the contact blades reach the isolating distance, the auxiliary contact blade opens the connection suddenly. The breaking arc (8) burns in a small gap, and the thermal effect releases enough gas to extinguish the arc rapidly and effectively. C D HG1-119a eps D: Switch in open position, arc extinguished. HG1-10a eps Representation of the disconnecting and arc-extinguishing process Flat arcing chamber 7 Current flow (yellow) 5 Contact blade 8 Breaking arc Auxiliary contact blade 5 Siemens HG
8 Description Construction and mode of operation CJ Switch-Disconnectors 1 1 Energy store of the switch-disconnector 1 Operating shaft Torsion bar spring (in operating shaft) Additional springs R-HG1-0.eps Switching process The switch-disconnector can be equipped with a springoperated or stored-energy mechanism. Both mechanism types decouple the actuation of the operating shaft from the actual switching process. When the operating shaft (1) is actuated manually or by motor, the torsion bar springs () located in the operating shaft are pre-charged, forming an energy store. At the end of the rotary movement, a cam plate releases the latch, and thus the energy store. In this way, the closing and opening speed is independent of the operator. In stored-energy mechanisms (STO), additional springs () are charged during the closing process, and used as energy stores for the opening operation. Opening can now be done by actuation of the operating shaft or free tripping (tripping by operation of a fuse or a shunt release). Operating mechanism CJ switch-disconnectors can be operated locally by hand or from remote by means of a motor operating mechanism. A motor operating mechanism is also available on request for the make-proof earthing switch. Fuse assembly HG1-11 eps Fuse assembly The fuse assembly is mounted on a base frame attached at the pivot point of the switch-disconnector. On this base frame, the post insulators and contact pieces are mounted as well. The tripping mechanism is directly connected to the switch-disconnector tripping system. The tripping mechanism can only operate the switch if the switch is equipped with a stored-energy mechanism. EO EP HG1-1_en eps If a CJ with fuse assembly has to be installed with the isolating contact side downwards (180 turn), this has to be specified as a special design due to the different force conditions (effect against the force of gravity). Faster breaking according to IEC with 100 A fuses (1 kv) and 80 A fuses (4 kv) is also possible as a special design. Make-proof earthing switch Make-proof earthing switches can be mounted on the opening side (EO), the pivot point (EP), and the fuse crossmember (EF). If the make-proof earthing switch has to be mounted on the fuse cross-member, it will be located inside the base frame for the type CJ5, and outside the base frame for all other switch-disconnector types. EO EF inside EF outside Mounting options of the make-proof earthing switch HG1-1_en eps High-speed closing of the earthing switch operating mechanism takes place via tilt springs. When the shaft is operated, the dead point is passed after approx. 15, and the highspeed closing is activated. Mechanical interlocking between the make-proof earthing switch and the switch-disconnector is always possible (with restrictions in case of motor operating mechanisms). 8 Siemens HG
9 CJ Switch-Disconnectors Description Construction and mode of operation, standards Shunt release For remote tipping, CJ switch-disconnectors with stored-energy mechanism can be equipped with a shunt release (1). For control via maintained contact, the tripping current must be interrupted by an auxiliary switch operated by the switch-disconnector; otherwise, the tripping coil will be overloaded. A shunt release only works on a switch-disconnector with a stored-energy mechanism. Switch-disconnector with stored-energy mechanism and built-on release (1) 1 R-HG1-04.eps 1 Auxiliary switch CJ switch-disconnectors can be delivered with auxiliary switches with NO + NC or 5 NO + 5 NC; the type CJ4 with a maximum of NO + NC. Make-proof earthing switches are supplied with NO + NC. The auxiliary switch is mounted on the switch-disconnector between phases L1 and L. If auxiliary switches are also required for built-on make-proof earthing switches, they are located between phases L and L in case of pivot-point arrangement and between phases L1 and L for arrangement on the opening side. Built-on auxiliary switch R-HG1-05.eps Spherical joint mechanism Spring-operated switch-disconnectors can also be operated through a spherical joint mechanism. The rotary movement is transmitted from the front side of a switchgear panel to the switch via levers and rods. 1 Spherical joint mechanisms are also available for the makeproof earthing switches. HG1-14 eps Standards The switch-disconnectors conform to the following standards and recommendations: VDE (former VDE 070 Part ) VDE (former VDE 070 Part ) IEC 19 IEC 05-1 IEC 094 (VDE 070 Part 1000) IEC (VDE 070 Part 0/9.94) Spherical joint mechanism DX 1 Operating shaft lever Switching rod (threaded rod with spherical joints M1 on both sides) Lever on the drive shaft 4 Drive shaft: steel shaft with 5 mm Ø, or insulating shaft with 0 mm Ø 5 Notch (only for disconnector and earthing switch) stop CLOSE-OPEN 7 Indication label black for switch-disconnector and disconnector red for earthing switch and make-proof earthing switch 8 Operating lever for spherical joint mechanism DX Siemens HG
10 Description Ambient conditions, dielectric strength and product range overview CJ Switch-Disconnectors Ambient conditions 40 C The switch-disconnectors are designed for the normal operating conditions defined in the standards. 1-0 C max. 95% per day max. 70% per month Condensation can occasionally occur under the ambient conditions shown opposite. HG1-15_en eps 1.50 Dielectric strength Altitude correction factor HG11-517c_en eps m 4000 Site altitude The dielectric strength of air insulation decreases with increasing altitude due to low air density. According to IEC 71-1, the values of the rated lightning impulse withstand voltage and the rated short-duration power-frequency withstand voltage specified in the chapter Technical Data apply to a site altitude of 1000 m above sea level. For an altitude above 1000 m, the insulation level must be corrected according to the opposite diagram. The characteristic shown applies to both rated withstand voltages. To select the devices, the following applies: U W U 0 x K a U U 0 K a Rated withstand voltage under reference atmosphere Rated withstand voltage requested for the place of installation Altitude correction factor according to the opposite diagram Example For a requested rated lightning impulse withstand voltage of 75 kv at an altitude of 500 m, an insulation level of 90 kv under reference atmosphere is required as a minimum: 90 kv W 75 kv x 1. Product range overview Rated voltage Type of operating mechanism Rated normal current (A) kv Spring-operated (SPR) Stored-energy (STO) 17.5 Spring-operated (SPR) Stored-energy (STO) 4 Spring-operated (SPR) Stored-energy (STO) Spring-operated (SPR) Stored-energy (STO) CJ with fuse assembly CJ without fuse assembly 10 Siemens HG
11 CJ Switch-Disconnectors Equipment Selection Contents Contents Page Equipment Selection 11 Ordering data and configuration example 1 Selection of basic type, switch-disconnector: Voltage level 1 kv 1 Voltage level 17.5 kv 1 Voltage level 4 kv 1 Voltage level kv 14 Selection of operating mechanism and built-on components: Design of operating mechanism 14 Design of motor operating mechanism 14 Switch-disconnector with earthing switch R-HG1-0.tif Design of shunt release Design of make-proof earthing switch Design of auxiliary switch Special version / Additional equipment 1 Accessories and spare parts 17 R-HG1-07.tif Switch-disconnector with fuse assembly Siemens HG
12 Equipment Selection Ordering data and configuration example CJ Switch-Disconnectors Order number structure The switch-disconnectors are described by a 1-digit order number. The positions 1 to 1, which are provided for the usual 1-digit order number, are not required. These 1 characters describe the data of the switch. Built-on components and special versions ( ) For some built-on components and special versions, -Z is added to the order number and a descriptive order code follows. If several built-on components and special versions are required, the suffix -Z is listed only once. If a requested special version is not in the catalog and can therefore not be ordered via order code, it has to be identified with Y 9 9 after consultation. The agreement hereto is made directly between your responsible sales partner and the order processing department in the Switchgear Factory Berlin. Primary data 1 st position Superior group Switching devices nd position Main group Switch and switch-disconnector rd position Subgroup Indoor switch-disconnector, -pole 4 th to 7 th position Basic equipment Design and ratings of the switch-disconnector a: alphabetical n: numerical Position: Ordercodes Order No.: C J n n n n a a n n Secondary data 8 th to 1 th position Operating mechanism and components Built-on components, special versions ( ) Initiated with -Z GroupofaftertheOrderNo. Format: a n n Configuration example In order to simplify the selection of the correct order number for the requested switch type, you will find a configuration example on each page of the chapter Equipment Selection. For the selection of the operating mechanism and built-on component types, always the last example of the primary part was taken over and continued, so that at the end of the equipment selection (page 1) a completely configured switch results as an example. On the foldout page we offer a configuring aid. Here you can fill in the order number you have determined for your switch. Example for Order No.: C J 5 4 Order codes: 1 Siemens HG
13 CJ Switch-Disconnectors Equipment Selection Selection of basic type, switch-disconnector 1 kv Position: Ordercodes 50/0 Hz Order No.: C J Rated voltage Rated lightning impulse withstand voltage earth/isolating distance Rated short-dur. powerfreq. withstand voltage earth/isolating distance Rated normal current Pole-center distance Shaft length 1) Type of oper. mechanism Spring-oper. mech. (SPR) Stored-ener. mech. (STO) Built-on component: with fuse (Fu) ) without fuse (w/ofu) Seepage14 Seepage14 Seepage14 Seepage15 Seepage15 Seepage1 U r U p U d I r PCD SL kv kv kv A mm mm 1 75/85 8/ STO Fu 9 C J STO Fu 9 C J SPR w/ofu C J 4 1 STO w/ofu C J SPR w/ofu C J 1 STO w/ofu C J SPR w/ofu C J 7 1 1) With motor operating mechanism, the shaft length sometimes deviates from the specified values (for actual values, refer to chapter Technical Data ) ) Specification of fuse dimension in mm 17.5 kv 50/0 Hz U r kv U p kv U d kv I r A PCD mm SL mm Type of operating mechanism Built-on component /110 8/ STO Fu 9 C J STO Fu 9 C J SPR w/ofu C J SPR w/ofu C J kv 50/0 Hz U r U p U d I r PCD SL Type of operating kv kv kv A mm mm mechanism Built-on component 4 15/145 50/ STO Fu 44 C J STO Fu 44 C J SPR w/ofu C J 5 1 STO w/ofu C J SPR w/ofu C J 1 STO w/ofu C J SPR w/ofu C J Configuration example CJ switch-disconnector C J Rated voltage U r =4kV Rated lightning impulse withstand voltage U p = 15 kv Rated short-duration power-frequency withstand voltage U d =50kV Rated normal current I r = 400 A Pole-center distance PCD = 50 mm, shaft length SL = 8 mm Type of operating mechanism: stored-energy mechanism, components: with fuse assembly 5 4 Example for Order No.: C J 5 4 Order codes: Siemens HG
14 Equipment Selection CJ Switch-Disconnectors Selection of basic type, switch-disconnector / Selection of operating mechanism and built-on components kv Position: Ordercodes 50/0 Hz Order No.: C J Rated voltage Rated lightning impulse withstand voltage earth/isolating distance Rated short-dur. powerfreq. withstand voltage earth/isolating distance Rated normal current Pole-center distance Shaft length 1) Type of oper. mechanism Spring-oper. mech. (SPR) Stored-ener. mech. (STO) Built-on component: with fuse (Fu) ) without fuse (w/ofu) Seepage15 Seepage15 Seepage15 Seepage1 U r U p U d I r PCD SL kv kv kv A mm mm 170/195 70/ SPR w/ofu C J 1 1 STO Fu 57 C J SPR w/ofu C J 1 STO Fu 57 C J SPR w/ofu C J SPR w/ofu C J 7 1 1) With motor operating mechanism, the shaft length sometimes deviates from the specified values (for actual values, refer to chapter Technical Data ) ) Specification of fuse dimension in mm 8 th position Design of operating mechanism Equipment with operating shaft lever: with/without Operating mechanism: left/right Without (for motor operating mechanism) Right 1 Without (for motor operating mechanism) Left With (for manual operating mechanism) ) Right With (for manual operating mechanism) ) Left 4 ) At the 9 th position: A 9 th position Design of motor operating mechanism DC voltage AC voltage Without motor operating mechanism 4) A 4 V DC B 0 V DC C 110 V DC D 15 V DC H 0 V DC E 110 V AC 50/0 Hz F 0 V AC 50/0 Hz G 4) At the 8 th position: or 4 Configuration example CJ switch-disconnector C J Rated voltage U r =kv Rated lightning impulse withstand voltage U p = 170 kv Rated short-duration power-frequency withstand voltage U d =70kV Rated normal current I r = 0 A Pole-center distance PCD = 400 mm, shaft length SL = 1500 mm Type of operating mechanism: stored-energy mechanism; built-on component: with fuse assembly Equipment for manual operating mechanism: with operating shaft lever, operating mechanism on the right Without motor operating mechanism A Example for Order No.: C J A Order codes: 14 Siemens HG
15 CJ Switch-Disconnectors Equipment Selection Selection of operating mechanism and built-on components 10 th position Position: Ordercodes Design of shunt release Order No.: C J DC voltage AC voltage Seepage1 A Without shunt release 1) ) 4 V DC B 0 V DC C 110 V DC D 15 V DC H 0 V DC E 110 V AC 50/0 Hz F 0 V AC 50/0 Hz G 1) Basically for switch-disconnectors with spring-operated mechanism ) Not for switch-disconnectors with stored-energy mechanism and without fuse assembly 11 th position Design of make-proof earthing switch Built-on make-proof earthing switch Mechanical interlocking Without make-proof earthing switch 0 With make-proof earthing switch on pivot-point side ) Without With make-proof earthing switch on pivot-point side ) With 4 With make-proof earthing switch on opening side Without 5 With make-proof earthing switch on opening side With With make-proof earthing switch on fuse cross-member 4) Without 7 With make-proof earthing switch on fuse cross-member 4) With 8 ) Not for switch-disconnectors with fuse assembly 4) Only for switch-disconnectors with fuse assembly 1 th position Design of auxiliary switch Built on the switch-disconnector Built on the make-proof earthing switch NO+NC NO+NC 5NO+5NC 5) NO+NC Without auxiliary switch ) Not available for switch-disconnector with PCD 15 mm Configuration example CJ switch-disconnector C J (U r =kv, I r = 0 A,PCD=400 mm,sl=1500 mm with stored-energy mechanism, with fuse assembly) A With shunt release 4 V DC B With make-proof earthing switch on the opening side and with mechanical interlocking With auxiliary switch NO + NC at the switch-disconnector and NO + NC at the make-proof earthing switch Example for Order No.: C J A B Order codes: Siemens HG
16 Equipment Selection Special version / Additional equipment CJ Switch-Disconnectors Special version / Additional equipment Position: Ordercodes Order No.: C J Options Signaling switch 1 NO + 1 NC for fuse tripping Z B 0 1 Capacitive tap Z B 0 Design with upgrading according to IEC Z C 0 1 Design with category B upgrading (not for kv switches) Z C 0 Switch-disconnector fuse combination turned by 180 Z C 0 Design with insulating shaft Z C 0 4 Special length of the fuse dimension (only after consultation with the order processing dept. in Berlin). Length to be specified in clear text Z Y 0 1 Shortening the operating shaft (only after consultation with the order processing dept. in Berlin). Length to be specified in clear text Z Y 0 Shaft extension by means of joint or shaft piece. Length to be specified in clear text Z Y 0 Configuration example CJ switch-disconnector C J Rated voltage U r =kv Rated lightning impulse withstand voltage U p = 170 kv Rated short-duration power-frequency withstand voltage U d =70kV Rated normal current I r = 0 A Pole-center distance PCD = 400 mm Shaft length SL = 1500 mm Type of operating mechanism: stored-energy mechanism Built-on component: with fuse assembly Equipment for manual operating mechanism: with operating shaft lever, operating mechanism on the right Without motor operating mechanism A With shunt release 4 V DC B With make-proof earthing switch on the opening side and with mechanical interlocking With auxiliary switch NO + NC at the switch-disconnector and NO + NC at the make-proof earthing switch With signaling switch 1 NO + 1 NC for fuse tripping Z B 0 1 Example for Order No.: C J A B Z Order codes: B Siemens HG
17 CJ Switch-Disconnectors Equipment Selection Accessories and spare parts Remark for orders The order numbers are applicable to switch-disconnectors of current manufacture. When built-on components or spare parts are being ordered for an existing switch-disconnector, always quote the type designation, serial number and the year of manufacture of the switch-disconnector to be sure to get the correct delivery. Note: Arc-suppression systems and other spare parts must only be replaced by instructed personnel. Designation Remarks Order No. Operating shaft lever For switch-disconnector CX105 For make-proof earthing switch CX10 Switching rod To actuate the operating shaft lever Length 105 mm PFS: up to kv Length 000 mm PFS: Auxiliary mechanism For motor operating mechanism Length 80 mm CX015 Arc-suppression system 1 kv CY kv CY057 4 kv CY058 kv CY08 Conducting path For 1 kv 400 A CY0 0 A CY A CY070 For 17.5 kv 400 A CY04 0 A CY0 For 4 kv 400 A CY0 0 A CY A CY07 For kv 0 A CY A CY07 Siemens HG
18 Equipment Selection Accessories and spare parts CJ Switch-Disconnectors Designation Remarks Order No. Spherical joint mechanism for CJ -1/ switch-disconnectors with spring-operated mechanism (data of widths X and L in clear text) For switch-disconnector For recommended panel width CJ mm DX011 X =... L =... CJ mm DX01 X =... L =... CJ mm DX011 X =... L =... CJ mm DX01 X =... L =... CJ mm DX011 X =... L =... CJ mm DX01 X =... L =... CJ DX01 X =... L =... Spherical joint mechanism for make-proof earthing switch (data of widths X and L in clear text) For switch-disconnector For recommended panel width CJ mm DX01 X =... L =... CJ mm DX014 X =... L =... CJ mm DX01 X =... L =... CJ mm DX014 X =... L =... CJ mm DX01 X =... L =... CJ mm DX014 X =... L =... CJ DX014 X =... L =... Accessories for spherical joint Operating lever for switch-disconnector DX081 mechanism Operating lever for make-proof earthing switch DX08 Interlocking between switch-disconnector and make-proof earthing switch DX07 Additive blocking solenoid with data of operating voltage DX071-Z Bearing for shaft extension DX901 Setting lever for switchgear DX90 Dowel pin for shaft extension DX90 Data of spherical joint mechanism X 1 L 70 HG1-15 eps DX spherical joint mechanism 1 Operating shaft lever Switching rod (threaded rod with spherical joints M1 on both sides) Lever on the drive shaft 4 Drive shaft: steel shaft with 5 mm Ø, or insulating shaft with 0 mm Ø 5 Notch (only for disconnector and earthing switch) stop CLOSE-OPEN 7 Indication label black for switch-disconnector and disconnector red for earthing switch and make-proof earthing switch 8 Operating lever for spherical joint mechanism DX Siemens HG
19 CJ Switch-Disconnectors Technical Data Contents Contents Technical Data Electrical data, dimensions and weights: Voltage level 1 kv Voltage level 17.5 kv Voltage level 4 kv Voltage level kv Dimension drawings Circuit diagrams Data of auxiliary switch Data of motor operating mechanism Page Arcing chambers, contact blades and auxiliary contact blades R-HG1-08.tif Fuse holders with separating shells R-HG1-09.tif Siemens HG
20 Technical Data Electrical data, dimensions and weights CJ Switch-Disconnectors 1 kv 50/0 Hz Order No. Rated lightning impulse withstand voltage to earth Rated lightning impulse withstand voltage across the isolating distance Rated short-duration power-frequency withstand voltage to earth Rated short-duration power-frequency withstand voltage across the isolating distance Rated normal current Rated short-time withstand current (1 s) Rated peak withstand current Rated short-circuit making current Rated closed-loop breaking current Rated cable-charging breaking current Rated earth-fault breaking current Rated cable-charging breaking current under earth-fault conditions Number of mechanical operating cycles Pole-center distance Shaft length (standard) Shaft length (with built-on motor) Dimension of fuse assembly Torque of spring-operated mechanism Torque of stored-energy mechanism Torque of make-proof earthing switch Weight of switch-discon./built-on earth. switch Catalog dim. drawing no. (see pages 1 to ) U p U p U d U d I r I k I p I ma I a I 4a I a I b n e kv kv kv kv A ka ka ka A A A A mm mm mm mm Nm Nm Nm kg CJ ) 1) / 10.5 CJ / 9.5 CJ / 9.5 CJ / 9.5 CJ ) 1) / 8 CJ / 8 CJ / kv 50/0 Hz U p U p U d U d I r I k I p I ma I a I 4a I a I b n e kv kv kv kv A ka ka ka A A A A mm mm mm mm Nm Nm Nm kg CJ ) 1) / 10 CJ / 10 CJ ) 1) / 10 CJ / kv 50/0 Hz U p U p U d U d I r I k I p I ma I a I 4a I a I b n e kv kv kv kv A ka ka ka A A A A mm mm mm mm Nm Nm Nm kg CJ ) 1) / 10.5 CJ / 10.5 CJ / 10.5 CJ / 10.5 CJ ) 1) / 11.5 CJ / ) I ma and I k aredefinedbythefuseused Siemens HG
21 CJ Switch-Disconnectors Technical Data Electrical data, dimensions and weights / Dimension drawings kv 50/0 Hz Order No. Rated lightning impulse withstand voltage to earth Rated lightning impulse withstand voltage across the isolating distance Rated short-duration power-frequency withstand voltage to earth Rated short-duration power-frequency withstand voltage across the isolating distance Rated normal current Rated short-time withstand current (1 s) C C Rated peak withstand current Æ Æ , Rated short-circuit making current C C ,5 15 Rated closed-loop breaking current Rated cable-charging breaking current Dimension drawings for 1 kv Æ14 Æ0 1 Rated earth-fault breaking current Rated cable-charging breaking current under earth-fault conditions Number of mechanical operating cycles Pole-center distance Shaft length (standard) Shaft length (with built-on motor) Dimension of fuse assembly Torque of spring-operated mechanism Torque of stored-energy mechanism Torque of make-proof earthing switch Weight of switch-discon./built-on earth. switch Catalog dim. drawing no. (see pages 1 to ) U p U p U d U d I r I k I p I ma I a I 4a I a I b n e kv kv kv kv A ka ka ka A A A A mm mm mm mm Nm Nm Nm kg CJ / 1 CJ ) ) / 1 CJ / 1 CJ / 1 CJ ) ) / 1 CJ / ) I ma and I k aredefinedbythefuseused Korr. Maßzeichnungen konnten noch nicht eingebaut werden, da Hr. Schleicher z.zt. Urlaub hat! Dimension drawing 1 D B A HG1-1 eps Dimension drawing no Dimension drawing D B A Type A B C D HG1-17 eps 1 / CJ / CJ Siemens HG
22 Technical Data Dimension drawings CJ Switch-Disconnectors Korr. Maßzeichnungen konnten noch nicht eingebaut werden, da Hr. Schleicher z.zt. Urlaub hat! Dimension drawings for 17.5 kv to kv Æ14 Æ Æ Æ Dimension drawing 00 5 A HG1-18 eps 540 Dimension drawing 4 Dimension drawing no A Type A B C D HG1-19 eps C C /4 CJ /4 CJ / CJ / CJ , Æ14 Æ , C C Æ14 0 Æ Dimension drawing 5 D B A HG1-10 eps 7 Dimension drawing D B A HG1-11 eps /400 1) 70/400 1) ,5 5,5 Æ Æ0 7, HG1-1 eps Dimension drawing 7 1) 70 mm for switch CJ mm for switch CJ... Siemens HG
23 CJ Switch-Disconnectors Technical Data Dimension drawings / Circuit diagrams Korr. Maßzeichnungen konnten noch nicht eingebaut werden, da Hr. Schleicher z.zt. Urlaub hat! Dimension drawing for kv /400 1) 70/400 1) ,5 5,5 Æ , Æ HG1-1 eps Dimension drawing 8 1) 70 mm for switch CJ mm for switch CJ... Circuit diagrams F S1 Control voltage 5 K1A S1A K1E S1E OPEN CLOSED S F K1A S4 Motor voltage K1E Auxiliary switch (for data refer to next page) S X1 HG1-17 eps S S 7 8 M1 M 4 NO + NC S K1A K1E F K1E K1A K1A K1E F 1 HG1-1_en eps NO + NC X1 HG1-18 eps S1 1 4 F1 HG1-140a eps X 1 4 S4 M M1 5 S S 7 8 HG1-141 eps S1 X1 P HG1-19 eps Shunt release Motor operating mechanism 5 NO + 5 NC Legend F1 Shunt release Open F, Electro-thermal over- F current release K1A Auxiliary contactor Feedback K1E Auxiliary contactor Closed M1 Motor operating mechanism S1 Auxiliary switch at the switch S, Position switches S S4 Interrupter contact for manual emergency operation S1E S1A S1 CLOSE pushbutton OPEN pushbutton Auxiliary switch for tripping signal The circuit diagrams shown here are examples from the manifold possibilities of switch wiring S X1 X Interrupter contact (only for make-proof earthing switch) Terminal strip on the switch Terminal strip on the motor Siemens HG
24 Technical Data Data of auxiliary switch / Data of motor operating mechanism CJ Switch-Disconnectors Korr. Maßzeichnungen konnten noch nicht eingebaut werden, da Hr. Schleicher z.zt. Urlaub hat! Data of auxiliary switch Rated operating voltage Switching capacity Short-circuit capability Time coefficient T=L/R V A ka ms 4 DC DC DC DC DC AC AC 10 1 Data of motor operating mechanism 4 kv = 0 17,5 kv + 1 kv = 5 HG1-14 eps 4 kv = 17 17,5 kv + 1 kv = Rated operating voltage Maximum current consumption Maximum power consumption V A W/VA 4 DC DC DC DC DC AC AC Siemens HG
25 CJ Switch-Disconnectors Annex Contents Contents Annex Page 5 Inquiry form Configuration instructions Configuration aid 7 Foldout page Brandenburg Gate, Berlin, Germany R-HG tif 4 Switchgear Factory in Berlin, Germany R-HG eps Siemens HG
26 Annex Inquiry form CJ Switch-Disconnectors Please copy, fill in and return to your Siemens partner. Inquiry concerning Technical data Other values CJ switch-disconnector Rated voltage 1 kv 4 kv 17.5 kv kv kv Rated lightning impulse withstand voltage 75 kv 15 kv 95 kv 170 kv kv Please Rated short-duration powerfrequency withstand voltage 8 kv 50 kv 8 kv 70 kv kv Submit an offer Call us Visit us Rated normal current 400 A 0 A 1000 A A Type of operating mechanism Spring-operated mechanism Stored-energy mechanism Fuse assembly Without With Your address Pole-center distance Shaft length 15 mm 75 mm 5 mm 8 mm 10 mm 70 mm 50 mm 400 mm mm 7 mm 9 mm 1500 mm mm Company Dept. Name Street Postal code/city Phone Fax Secondary equipment For possible combinations see pages 14 and 15 Actuation of operating shaft Manual operation Motor operation Motor operating mechanism VDC VAC, Hz Shunt release VDC VAC, Hz Auxiliary switch NO+NC NO+NC 5NO+5NC Built-on make-proof earthing switch On opening side On pivot point On fuse cross-member 4 Siemens AG Application and other requirements Dept. Name Street Postal code/city Fax Please check off _ Please fill in Siemens HG
27 You prefer to configure your switch-disconnector on your own? Please follow the steps for configuration and enter the order number in the configuration aid. For configuration of your CJ switch-disconnector Instruction for configuration of the CJ switch-disconnector C J Z 1 st step: Definition of the primary part (see pages 1 and 14) Please specify the following ratings: Possible options: Rated voltage (U r ) U r : 1kVtokV Rated lightning impulse withstand voltage (U p ) U p : 75 kv to 170 kv Rated short-duration power-frequency withstand voltage (U d ) U d : 8kVto70kV Rated normal current (I r ) I r : 400 A to 1000 A Pole-center distance (PCD) PCD: 15 to 400 mm Shaft length (SL) of the switch shaft SL: 7 to 1500 mm Type of operating mechanism Spring-operated or stored-energy mechanism Version with fuse With or without fuse assembly These ratings define the positions 5 to 7 of the order number. Seepage1and14 Seepage14 Seepage14 Seepage15 Seepage15 Seepage15 C J C J Seepage1 nd step: Definition of the secondary equipment (see pages 14 and 15) C J Please specify the following equipment features: Type of operating mechanism (position 8) Operating voltage of the motor operating mechanism (position 9) Use of releases (position 10) Use of make-proof earthing switches (position 11) Use of auxiliary switches (position 1) These equipment features define the positions 8 to 1 of the order number. Possible options: Manual operating mechanism with operating shaft lever Motor operating mechanism Operating voltages from 4 V DC to 0 V AC Operating voltages from 4 V DC to 0 V AC Built on the opening side, the pivot point or the fuse cross-member NO+NC,NO+NC,5NO+5NC C J C J C J rd step: Do you have any further requirements concerning the equipment? (Please refer to page 1) Should you still need more options than the possible special equipment like upgrading to category B, signaling switch for fuse tripping, special lengths of fuse dimensions, etc., please contact your responsible sales partner. C J C J C J Siemens HG
28 Published by and copyright 008: Siemens AG Energy Sector Freyeslebenstrasse Erlangen, Germany Siemens AG Energy Sector Power Distribution Division Medium Voltage Nonnendammallee Berlin, Germany For more information, please contact our Customer Support Center. Phone: Fax: (Charges depending on provider) support.energy@siemens.com Order No. E50001-K151-A11-A1-700 Printed in Germany Dispo 101 KG En 101/ Printed on elementary chlorine-free bleached paper. All rights reserved. If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks or product names of Siemens AG or other suppliers. If not stated otherwise, all dimensions in this catalogaregiveninmm. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which maynotapplyinallcases.therequiredtechnical options should therefore be specified in the contract. Responsible for Technical contents: Siemens AG, E D MV C Berlin General editing: Siemens AG, E CC MCC R Erlangen
3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010
Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage
More informationHigh-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv
High-Voltage Compact Switchgear AP1 DTC for 1 kv and kv Answers for energy. The AP1 DTC Complying with our Customers demands Experience you can rely on - at anytime, anywhere Decades of experience in high-voltage
More informationUniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationHigh-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution
High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching
More informationNATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More information7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units
Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast changing world. We help our customers worldwide
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationSiemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens.
Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany www.siemens.com/energy For questions on power transmission and distribution, please contact
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationSICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A
s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationOur brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy
Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility
More information2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More information225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationSiemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver
www.siemens.com/fusesaver Siemens Fusesaver Highest availability and cost savings for your MV distribution network Answers for infrastructure and cities. 2 In high demand: An intelligent solution Improving
More informationMedium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationDead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationSafety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationSF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More information3TL Vacuum Contactors Selection and Ordering Data. www.siemens.com/3tl. Medium-Voltage Equipment Catalog HG 11.21 2014
www.siemens.com/3tl 3TL Vacuum Contactors Selection and Ordering Data Medium-Voltage Equipment Catalog HG 11.21 2014 Answers for infrastructure and cities. R-HG11-343.psd 2 Siemens HG 11.21 2014 Contents
More informationCAS 36 Ring Main Unit
Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly
More informationwww.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.
s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationAdvantages of Fixed Circuit Breaker Switchgear
Advantages of Fixed Circuit Breaker Switchgear by Lionel Mackay, EDF Energy, and Mike Adams, Schneider Electric Ltd Introduction The purpose of this paper is to review the advantages of fixed circuit breaker
More informationAutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationVoltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125
Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More information225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.
More informationThe Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationTechnical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10
ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationUFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationwww.siemens.com/energy/arresters A full range of monitoring solutions for surge arresters Answers for energy.
www.siemens.com/energy/arresters A full range of monitoring solutions for surge arresters Answers for energy. Highly reliable equipment monitoring with added value ACM advanced ACM basic and LCM 500 Overview
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG TEL. +49 87 61 6 81-0 FAX +49 87 61 68 12 30
40 DRIESCHER - Low voltage fusedswitch-disconnector system 40 Rated current upto 445 A 40 84 40 40 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-8566 MOOSBURG TEL. +49 87 6 6 8-0 FAX +49 87 6
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationEngineering Specification
Engineering Specification Electrical 33KV AC INDOOR SWITCHGEAR NON-WITHDRAWABLE Owner: Approved by: Chief Engineer, Electrical Neal Hook Chief Engineer Electrical Authorised by: Version 2.1 Issued May
More informationType-Tested Power Distribution Board 8PT with Rear Busbars. sivacon
Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will
More informationProven vacuum switching technology from Siemens meets all requirements placed on circuit-breakers and contactors in medium-voltage switchgear up to
Proven vacuum switching technology from Siemens meets all requirements placed on circuit-breakers and contactors in medium-voltage switchgear up to 40.5 kv. 2 Contents Overview of medium-voltage components
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationCurrent and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationTrip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationThe complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationDocumentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationPower consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95
Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationDATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS
DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS ABSTRACT Data Centers are a critical part of the world economic systems. Billions of electronic transactions happen
More informationCircuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04
Circuit Breaker LTB D with Motor Drive Motor Drive ABB PP/H/HV - Page 1 Ed 2006-04 Technology Traditional technology Traditional spring operating mechanism: Closing mechanism ABB PP/H/HV - Page 2 Tripping
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationOUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd
OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132
More information