1 kw Protective Relaying Training System LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 02/2017

2 Table of Contents General Description 2 Features & Benefits 3 List of Available Training Systems 3 Additional Equipment Required to Perform the Exercises 3 Optional Equipment 3 Available Training Systems 4 Equipment Description 10 General Description The 0.2 kw Protective Relaying Training System is a complete program that extends training in protective relaying beyond the operation and calibrations of individual relays into broader circuit applications. The program provides hands-on training at the system level in Generator Protection, Transformer Protection, and Induction Motor Protection. The 0.2 kw Protective Relaying Training System consists of several modules, which can be divided into five groups: Common Electrical Modules, Power System Modules (Series 3700), Protective Relaying Control Station, Protective Relays (Series 3800), and Additional and Optional Equipment. These modules are described in detail below: Common Electrical Modules Power supply, synchronous generator, induction motor, prime mover / dynamometer, resistive loads, voltmeters, ammeters, and others. Most of these modules are part of the 0.2 kw ElectroMechanical System (EMS), 8001 or Power System Modules, Series 3700 Modules specially designed for training in the protective relaying area, including current transformers, voltage transformers, power transformers, source impedances, a transmission grid, and others. These modules are designed to be installed in an EMS workstation. Protective Relaying Control Station A mobile rack for protective relay operation, including a dc power supply, dc control relays for system studies, and an interconnection panel to facilitate connection of the protective relays to the system to be protected. Protective Relays, Series 3800 Selection of protective relays. Each relay is mounted on a metal panel which facilitates relay installation in the Protective Relaying Control Station. Each relay panel is equipped with fault switches that allow fault insertion for troubleshooting at the system level. The following types of protective relays are available: undercurrent/overcurrent, undervoltage/overvoltage, synchronism check, underfrequency/over-frequency, phase balance, phase sequence, reverse power, and power factor. Additional and Optional Equipment Various modules, such as distribution busses, a ring bus, transmission lines, distribution transformers, protective relays, and reactive loads are available. These modules can be added to the basic 0.2 kw Protective Relaying Training System to allow the instructor to create more elaborate hands-on exercises. The 0.2 kw Protective Relaying Training System courseware consists of a student manual and an instructor guide. The student manual is divided into several units, each consisting of a series of hands-on exercises dealing with one of the fields of protective relaying mentioned above. Each exercise provides a clearly stated objective, a discussion, textbook references, a summary of the exercise procedure, a detailed exercise procedure, a conclusion, and a set of review questions. A ten-question test at the end of each unit allows the student to verify what was learned in the unit. Completion of some exercises in the student manual requires a digital storage oscilloscope and a digital multimeter, which must be purchased separately. 2 Festo Didactic

3 The instructor guide contains the practical results as well as the answers for each hands-on exercise in the student manual. It also contains the answers to the unit test questions in the student manual. The reference textbook provides more elaborate discussions of the theory presented in the student manual. The prerequisites for the 0.2 kw Protective Relaying Training System include: completion of a course in relay operation and calibration, and completion of a course in electric power technology that covers electric power generation, power transformers, and induction motors. The modular structure of the 0.2 kw Protective Relaying Training System, together with the subdivision of student manuals into topical units, enables instructors to choose equipment that matches their budgets while progressively enhancing their systems over time. For power utility users, it is possible to combine their own protective relays with a selection of modules from the 0.2 kw Protective Relaying Training System to obtain equipment setups that correspond to existing one-line and three-line diagrams. Features & Benefits Modular, industrial-grade system approach allowing: selection of areas of interest for study, and tailoring to special training needs equipment selection to match budgets setup of complete power systems/generators feeding various devices such as transformers, transmission lines, and others progressive system enhancement with no replication of equipment Use of many modules from other well-known Electromechanical System (EMS) Wide range of protective relays: undercurrent/overcurrent, undervoltage/overvoltage, synchronism check, underfrequency/overfrequency, phase balance, phase sequence, reverse power, and power factor. Fault insertion capability for troubleshooting at the system level Very safe operation and experimentation Ability of power utility customers to combine their own protective relays with the 0.2 kw Protective Relaying Training System to obtain equipment setups that correspond to existing one-line and three-line diagrams Comprehensive curriculum with detailed lab procedures, exercises, theory, tests, etc. List of Available Training Systems kw Protective Relaying Training System kw Protective Relaying Training System Add-On 8007-A5 Additional Equipment Required to Perform the Exercises 1 1 Dual-Trace Digital Storage Oscilloscope Digital Multimeter Optional Equipment 1 Distribution Transformers Used in one exercise of the courseware. Festo Didactic 3

4 1 Ring Bus Distribution Bus 'A' Distribution Bus 'B' Transmission Grid 'B' Faultable Transmission Line Protective Relay Rack Single-Phase Under/Over Current Relay Single-Phase Under/Over Voltage Relay Phase Sequence Relay Workstation Inductive Load Three-Phase Transmission Line Capacitive Load Three-Phase Power-Factor Meter, 2kW Frequency Meter Three-Phase Full-Voltage Starter Available Training Systems 0.2 kw Protective Relaying Training System The 0.2 kw Protective Relaying Training System extends training in protective relaying beyond the operation and calibrations of individual relays into broader circuit applications. The system provides hands-on training in generator protection, transformer protection, and induction motor protection. The complete system consists of five groups of modules which include Common Electrical Modules, Power System Modules (3700 Series), Protective Relaying Control Station, Protective Relays (3800 Series), and Additional and Optional Equipment. Courseware consists of a Student Manual containing hands-on exercises in each of the module topics along with unit tests, an Instructor's Guide, and a reference textbook. The program requires completion of courses in relay operation and calibration, and electric power technology with coverage of electric power generation, power transformers, and induction motors. For power utility users, it is possible to combine industrial grade protective relays with a selection of modules from the Protective Relaying Training System to obtain equipment setups that correspond to existing one-line and three-line diagrams. 2 Can replace the Mobile Workstation, Festo Didactic

5 Features & Benefits Modular system approach allows: Selection of areas of interest for study. Equipment selection to match budgets. Set-up of complete power systems/generators feeding various devices such as transformers, transmission lines, and others. Progressive system enhancement. Use of many modules from the tried and proven LabVolt Electromechanical System (EMS). Fault-insertion capability for troubleshooting at the system level. All device connections are terminated with 4-mm safety banana jacks mounted on the module front panels. Ability of power utility customers to combine their own protective relays with the 0.2-kW Protective Relaying Training System to obtain equipment set-ups that correspond to existing one-line and three-line diagrams. List of Equipment 1 Source Impedance Current Transformers Current Transformers Voltage Transformers Faultable Transformers Transmission Grid 'A' Interconnection Module Universal Fault Module Protective Relaying Control Station Three-Phase Over Current Relay AC/DC Current Sensitive Relay Three-Phase Under/Over Voltage Relay AC/DC Voltage Sensitive Relay Synchro-Check Relay Under/Over Frequency Relay Phase Balance/Sequence Relay Reverse Power Relay Motor Power-Factor Relay Mobile Workstation Three-Module Workstation Storage Shelves Four-Pole Squirrel-Cage Induction Motor Synchronous Motor/Generator Resistive Load DC Voltmeter/Ammeter AC Ammeter AC Voltmeter Wattmeter / Varmeter Synchronizing Module Power Supply Power Diodes Festo Didactic 5

6 1 Timing Belt Connection Lead Set Four-Quadrant Dynamometer/Power Supply 8960-B5 1 Inertia Wheel List of Manuals Manual Description Introduction to Protective Relaying (Student Manual) Introduction to Protective Relaying (Instructor Guide) Electric Power Technology Training Equipment (User Guide) E0 Table of Contents of the Manual(s) Introduction to Protective Relaying (Student Manual) ( ) 1 Generator Protection 1-1 Differential Protection of a Synchronous Generator 1-2 Reverse Power Protection of a Synchronous Generator 1-3 Rotor Earth Fault Protection of a Synchronous Generator 1-4 Loss-of-Excitation Protection of a Synchronous Generator 1-5 Overvoltage Protection of a Synchronous Generator 1-6 Overspeed Protection of a Synchronous Generator 1-7 Overcurrent Protection of a Synchronous Generator 1-8 Generator Synchronization 1-9 Synchronous Generator Protection Scheme 2 Transformer Protection 2-1 Transformer Magnetizing Inrush 2-2 Differential Protection of a Three-Phase Power Transformer 2-3 Restricted Earth Fault Protection of a Three-Phase Power Transformer 2-4 Overcurrent Protection of a Three-Phase Power Transformer 2-5 Three-Phase Power Transformer Protection Scheme 3 Induction Motor Protection 3-1 Stator-Winding Fault Protection 3-2 Overcurrent Protection of a Three-Phase Induction Motor 3-3 Phase Reversal Protection of a Three-Phase Induction Motor 3-4 Phase Unbalance and Undervoltage Protection of a Three-Phase Induction Motor 3-5 Stall Protection of an Induction Motor 3-6 Mechanical Overload/Underload Protection of a Three-Phase Induction Motor Electric Power Technology Training Equipment (User Guide) (38486-E0) 1 General Safety Recommendations 2 System Power Requirements 3 Quick Start Installation Guide 4 Equipment Installation 5 Modules Handling, Installation, and Removal 6 Equipment Maintenance A Connection of the Power Supply to the AC Power Network 6 Festo Didactic

7 B Description,, and Operation of the EMS Modules Additional Equipment Required to Perform the Exercises 1 3 Training on Introduction to Protective Relaying, 1.4 days TF Optional Manual(s) kW Protective Relaying Training System (Manuals on CD-ROM) A0 System System Requirements Maximum Current Typical Current AC Power Network Installation 10 A 1 A per student group AC Power Network Connector NEMA L22-20 Intended Location 3 phases (220/380 V 50 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A circuit breaker On the floor (stands on casters, except for the Storage Cabinet) 1980 x 3000 x 800 mm (78 x x 31.5 in) 0.2 kw Protective Relaying Training System Add-On 8007-A5 TBE This equipment is an add-on to the 0.2 kw Protective Relaying Training System, It consists of a Source Impedance, a Current Transformer, a Voltage Transformer, a Faultable Transformer, a Transmission Grid 'A', an Interconnected Module, a Universal Fault Module, a Protective Relaying Control Station, a Three- Phase Over Current Relay, a AC/DC Current Sensitive Relay, a Three-Phase Under/Over Voltage Relay, an AC/DC Voltage Sensitive Relay, a Synchro-Check Relay, an Under/Over Frequency Relay, a Phase Balance/Sequence Relay, a Reverse Power Relay, a Motor Power-Factore Relay, a Three-Module Workstation, a Resistive Load, a Three-Phase Wattmeter/Varmeter, a Power Diodes module, Connection Leads, a Four-Quadrant Dynamometer/Power Supply, and an Inertia Wheel. Features & Benefits Modular system approach allows: Selection of areas of interest for study. Equipment selection to match budgets. 3 Optional product training. Price provided on demand. For details and options, contact services.didactic@festo.com. Festo Didactic 7

8 Set-up of complete power systems/generators feeding various devices such as transformers, transmission lines, and others. Progressive system enhancement. Use of many modules from the tried and proven LabVolt Electromechanical System (EMS). Fault-insertion capability for troubleshooting at the system level. All device connections are terminated with 4-mm safety banana jacks mounted on the module front panels. Ability of power utility customers to combine their own protective relays with the 0.2-kW Protective Relaying Training System to obtain equipment set-ups that correspond to existing one-line and three-line diagrams. List of Equipment 1 Source Impedance Current Transformers Current Transformers Voltage Transformers Faultable Transformers Transmission Grid 'A' Interconnection Module Universal Fault Module Protective Relaying Control Station Three-Phase Over Current Relay AC/DC Current Sensitive Relay Three-Phase Under/Over Voltage Relay AC/DC Voltage Sensitive Relay Synchro-Check Relay Under/Over Frequency Relay Phase Balance/Sequence Relay Reverse Power Relay Motor Power-Factor Relay Three-Module Workstation Resistive Load Wattmeter / Varmeter Power Diodes Connection Lead Set 8951-D0 1 Four-Quadrant Dynamometer/Power Supply 8960-B5 1 Inertia Wheel List of Manuals Manual Description Introduction to Protective Relaying (Student Manual) Introduction to Protective Relaying (Instructor Guide) Electric Power Technology Training Equipment (User Guide) E0 Table of Contents of the Manual(s) Introduction to Protective Relaying (Student Manual) ( ) 8 Festo Didactic

9 1 Generator Protection 1-1 Differential Protection of a Synchronous Generator 1-2 Reverse Power Protection of a Synchronous Generator 1-3 Rotor Earth Fault Protection of a Synchronous Generator 1-4 Loss-of-Excitation Protection of a Synchronous Generator 1-5 Overvoltage Protection of a Synchronous Generator 1-6 Overspeed Protection of a Synchronous Generator 1-7 Overcurrent Protection of a Synchronous Generator 1-8 Generator Synchronization 1-9 Synchronous Generator Protection Scheme 2 Transformer Protection 2-1 Transformer Magnetizing Inrush 2-2 Differential Protection of a Three-Phase Power Transformer 2-3 Restricted Earth Fault Protection of a Three-Phase Power Transformer 2-4 Overcurrent Protection of a Three-Phase Power Transformer 2-5 Three-Phase Power Transformer Protection Scheme 3 Induction Motor Protection 3-1 Stator-Winding Fault Protection 3-2 Overcurrent Protection of a Three-Phase Induction Motor 3-3 Phase Reversal Protection of a Three-Phase Induction Motor 3-4 Phase Unbalance and Undervoltage Protection of a Three-Phase Induction Motor 3-5 Stall Protection of an Induction Motor 3-6 Mechanical Overload/Underload Protection of a Three-Phase Induction Motor Electric Power Technology Training Equipment (User Guide) (38486-E0) 1 General Safety Recommendations 2 System Power Requirements 3 Quick Start Installation Guide 4 Equipment Installation 5 Modules Handling, Installation, and Removal 6 Equipment Maintenance A Connection of the Power Supply to the AC Power Network B Description,, and Operation of the EMS Modules Additional Equipment Required to Perform the Exercises 1 4 Training on Introduction to Protective Relaying, 1.4 days TF System System Requirements Maximum Current Typical Current AC Power Network Installation 10 A 1 A per student group AC Power Network Connector NEMA L phases (220/380 V 50 Hz), star (wye) configuration including neutral and ground wires, protected by a 20 A circuit breaker 4 Optional product training. Price provided on demand. For details and options, contact services.didactic@festo.com. Festo Didactic 9

10 Intended Location Installed in the workstation of the 0.2 kw Protective Relaying Training System, Equipment Description Source Impedance x 546 x 711 mm (74.5 x 21.5 x 28.0 in) TBE The Source Impedance consists of three inductors, one for each phase of a three-phase AC power network, installed in a half-height EMS module. An additional resistor, of small resistance value, is connected in series with each inductor to keep the reactance-resistance (X/R) ratio of the source impedance close to that of the synchronous generator. The Source Impedance module is designed to limit the short-circuit current drawn from the ac power source when response of protective relays is being tested. Ratings Impedance 137 Ω, 84 Nominal Phase Current Line-to-Line Voltage 0.5 A 380 V 155 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) 9.3 kg (20.5 lb) Current Transformers The Current Transformers consist of a set of six instrument-type current transformers installed in a half-height EMS module. Each transformer is equipped with a switch, mounted on the front panel, that allows the secondary winding to be shortcircuited. Current transformer ratios have been carefully selected to match the power equipment with the protective devices. CT1 to CT6 Current Ratio Primary Impedance 0.5:5 A 13.7 Ω 10 Festo Didactic

11 Apparent Power 5 VA Accuracy ±2% 155 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) 13.0 kg (28.6 lb) Current Transformers protective devices. The Current Transformers consists of a set of six instrument-type current transformers installed in a half-height EMS module. Each transformer is equipped with a switch, mounted on the front panel, that allows the secondary winding to be shortcircuited. Current transformer ratios have been carefully selected to match the power equipment with the CT1 to CT3 Current Ratio 1:5 A Primary Impedance 2.7 Ω Apparent Power 5 VA Accuracy ±2% CT4 to CT6 Current Ratio 2.5:5 A Primary Impedance 0.65 Ω Apparent Power 5 VA Accuracy ±2% 155 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) 13.0 kg (28.6 lb) Voltage Transformers The Voltage Transformers consists of a set of six instrument-type voltage transformers installed in a half-height EMS module. Voltage transformer ratios have been carefully selected to match the power equipment with the protective devices. VT1 to VT6 Voltage Ratio Apparent Power 380:120 V 8 VA Festo Didactic 11

12 Accuracy ±2% 155 x 287 x 440 mm (6.1 x 11.3 x 17.3 in) 10.2 kg (22.4 lb) Faultable Transformers TheFaultable Transformers consists of three single-phase power transformers installed in a full-height EMS module. Each transformer has multiple primary and secondary windings. Fault taps are wired to switches or banana jacks on the front panel for insertion of winding-to-earth5 and winding-towinding faults via current-limiting resistors. A current sensor is provided to observe the waveform of the primary current on transformer magnetizing inrush. T1 to T3 Primary Voltag Secondary Voltage Apparent Power Faults Fault Insertion T1 and T3 T2 Current Sensor Current Resistance 220/440 V 22/220/440 V 120 VA 3 (primary-earth, secondary-earth, primary-secondary) Through switches Remote 3 A 0.2 Ω 308 x 287 x 440 mm (12.1 x 11.5 x 17.3 in) 21.5 kg (47.3 lb) 12 Festo Didactic

13 Transmission Grid 'A' The Transmission Grid 'A' consists of a transmission grid installed in a fullheight EMS module. This module is used to open and close an ac power circuit under normal conditions or to interrupt this circuit under fault or abnormal situations. It can also be used for the connection of EMS motor/ generator sets and loads as well as the protective relaying equipment for transmission grid protection. The transmission grid is opened at intervals by eleven three-pole relays with normally open (NO) contacts. These relays can be operated by switches located on the module front panel or through the action of dc control relays or protective relays as part of a protection scheme. The module has a dc bus, energized from an external dc power supply, to distribute power to the relay coils. Interconnection Module The Interconnection Module consists of three sets of twelve 4 mm safety banana jacks and three multiplecontact connectors mounted on the front panel of a full-height EMS module. Three interconnection cables, supplied with the module, are used to connect the banana jacks on the Interconnection Module to the banana jacks on the interconnection panel of the Protective Relaying Control Station, 3806, via the multiple contact connectors. This provides an efficient means of interconnecting the electrical power system (EMS system) to the relays installed in the protective relaying control station. Ratings Voltage Current 450 V 5 A 308 x 287 x 440 mm (12.1 x 11.5 x 17.3 in) 6.9 kg (15.2 lb) Festo Didactic 13

14 Universal Fault Module The Universal Fault Module consists of control relays, adjustable time delay relays, contactors, a solid-state relay (SSR), current-limiting resistors, and an inductor, all installed in a fullheight EMS module. These components allow faults to be inserted into the electrical power system (EMS system) for training in protective relaying applications. Typical faults include line-to-line and line-to-earth resistive faults as well as resistive and inductive faults. Winding Inductive Fault Nominal Voltage 380 V Apparent Power 100 VA Line-to-Line Fault Type Resistive Resistor Ratings 500 Ω, 500 W Line-to-Earth Fault Type Resistive Resistor Ratings 200 Ω, 500 W Shunt Resistance 100 Ω Power 100 W 10 A at 120 V ac 10 A at 240 V ac Relay K1 Contact Ratings 25 A at 250 V ac Solid-State Relay (SSR) Maximum Current 25 A ac Maximum Voltage 250 V ac Relay TD1 Time Delay Range 0.1 to 3 s Relay SST1 Time Delay Range 0.1 to 10 s Relay SST2 Time Delay Range 0.6 to 60 s 308 x 287 x 440 mm (12.1 x 11.5 x 17.3 in) 12.4 kg (27.3 lb) 14 Festo Didactic

15 Protective Relaying Control Station power supply is used to energize the relay coils. The Protective Relaying Control Station is a standard 48 cm (19 in) rack, mounted on castors, that forms the basis of a typical protective relaying control station. Two sets of dc control relays, a dc power supply, and an interconnection panel are mounted on the rack. The two sets of dc control relays (six relays per set) allow basic contacts of protective relays (either normally open or normally closed contacts) to be converted into multiple normally open (NO) / normally closed (NC) contacts to actuate ac circuit breakers (contactors) in the electrical power system. Two of the dc control relays have adjustable time delay. The dc The interconnection panel consists of three sets of twelve 4 mm safety banana jacks mounted on a standard 48 cm (19 in) panel. Three multiple contact connectors, also mounted on the panel, allow connection of cables from the Interconnection Module, A set of metal rails and three standard 48 cm (19 in) blank panels are supplied with the Protective Relaying Control Station. The metal rails are used to mount the protective relays in the control station. Customers can use the three blank panels for mounting their own protective relays in the control station. DC Power Supply Input Voltage Input Current Output Voltage Output Current Control Relays 1 Coil Voltage Contact Ratings Control Relays 2 (CR1 to CR4) Coil Voltage Contact Ratings Control Relays 2 (TD1) Coil Voltage Contact Ratings Time Delay Range Control Relays 2 (TD2) Coil Voltage Contact Ratings Time Delay Range Interconnection Panel Voltage 220 V 50 Hz 3.5 A 120 V 5 A 120 V dc 3 A at 150 V dc; 10 A at 240 V ac 120 V dc 3 A at 150 V dc; 10 A at 240 V ac 120 V dc 0.5 A at 120 V dc; 10 A at 240 V ac 0.1 to 10 s 120 V dc 0.5 A at 120 V dc; 10 A at 240 V ac 0.6 to 60 s 450 V Festo Didactic 15

16 Current 15 A 1890 x 546 x 711 mm (74.5 x 21.5 x 28.0 in) kg (236.1 lb) Three-Phase Over Current Relay The Three-Phase Over Current Relay is a protective relay that is sensitive to overcurrent conditions in three-phase power systems. It trips when the current in any one of the three phases exceeds the current setpoint. Current setpoint and time delay adjustments are provided along with two sets of contacts. Ratings Nominal Input Current Maximum Input Current Current Setpoint Range Time Delay Range Output Contacts Auxiliary Supply Voltage Burden 5 A ac, each phase 200% of nominal input current 40% to 120% of nominal input current 0.5 to 10 s DPDT: 0.5 A at 120 V dc; 5 A at 240 V ac 220 V ac 4 VA 203 x 229 x 184 mm (8.0 x 9.0 x 7.2 in) 1.5 kg (3.3 lb) 16 Festo Didactic

17 AC/DC Current Sensitive Relay The AC/DC Current Sensitive Relay is a protective relay that is sensitive to either alternating current (ac) or direct current (ac). It can be set to respond to either undercurrent or overcurrent conditions. Current setpoint and hysteresis adjustments, ac/dc and undercurrent/overcurrent selection switches are provided along with a single set of contacts. Ratings Current Metering Ranges Maximum Input Current Current Setpoint Range Hysteresis Range Output Contacts Auxiliary Supply Voltage Burden 4 to 60 ma; 40 to 600 ma; 0.4 to 6 A 200 ma for the 4-60 ma range800 ma for the ma range8 A for the A range same as selected current metering range 5% to 50% of selected current metering range SPDT: 0.5 A at 120 V dc; 8 A at 250 V ac 220 V ac 2.5 VA 203 x 229 x 171 mm (8.0 x 9.0 x 6.7 in) 1.0 kg (2.2 lb) Three-Phase Under/Over Voltage Relay Festo Didactic 17

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated? Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux

More information

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt. Lab 9: Synchronous motor. Objective: to examine the design of a 3-phase synchronous motor; to learn how to connect it; to obtain its starting characteristic; to determine the full-load characteristic of

More information

3466 Building Energy Management Training Systems

3466 Building Energy Management Training Systems 3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available

More information

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331) Lab 5: Single-phase transformer operations. Objective: to examine the design of single-phase transformers; to study the voltage and current ratios of transformers; to study the voltage regulation of the

More information

VOLTAGE REGULATOR AND PARALLEL OPERATION

VOLTAGE REGULATOR AND PARALLEL OPERATION VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by

More information

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321) Lab 4: 3-phase circuits. Objective: to study voltage-current relationships in 3-phase circuits; to learn to make delta and Y connections; to calculate and measure real, apparent, and reactive powers. Equipment:

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd 100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center Introduction Roger Hedding Steven Schoenherr, P.E. ABB Inc. Minnesota Power 598 N. Buth Rd 3215 Arrowhead Rd Dousman,

More information

Unit 33 Three-Phase Motors

Unit 33 Three-Phase Motors Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation

More information

8086 Telephony Training Systems

8086 Telephony Training Systems 8086 Telephony Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 01/2016 Table of Contents General Description 2 Topic Coverage 6 Features & Benefits 6 List of Available Training

More information

Properties of electrical signals

Properties of electrical signals DC Voltage Component (Average voltage) Properties of electrical signals v(t) = V DC + v ac (t) V DC is the voltage value displayed on a DC voltmeter Triangular waveform DC component Half-wave rectifier

More information

Module Title: Electrotechnology for Mech L7

Module Title: Electrotechnology for Mech L7 CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Autumn Examinations 2012 Module Title: Electrotechnology for Mech L7 Module Code: ELEC7007 School: School of Mechanical, Electrical and Process

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection

More information

Electron S.R.L. A29 ELECTRICAL POWER SYSTEM TRAINERS. Production Transmission Distribution

Electron S.R.L. A29 ELECTRICAL POWER SYSTEM TRAINERS. Production Transmission Distribution lectron S..L. Design Production & Trading of ducational quipment A29 LCTICAL POW SYSTM TAINS Production Transmission Distribution FAX 9065 980 - -mail: electron@electron.it Web: www.electron.it ev 02 Specifications

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v1.0 2013 Spring web.itu.edu.tr/yumakk. Distance Protection

TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v1.0 2013 Spring web.itu.edu.tr/yumakk. Distance Protection Distance Protection Announcement: You are not supposed to prepare a pre-report. But there will be an oral examination, so you are strongly advised to study this note regarding to the pre-study questions

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392 1 Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading By Ramandeep Kaur Aujla S.NO 250447392 ES 586b: Theory and applications of protective relays Department of

More information

Lab 14: 3-phase alternator.

Lab 14: 3-phase alternator. Lab 14: 3-phase alternator. Objective: to obtain the no-load saturation curve of the alternator; to determine the voltage regulation characteristic of the alternator with resistive, capacitive, and inductive

More information

NATIONAL CERTIFICATE (VOCATIONAL)

NATIONAL CERTIFICATE (VOCATIONAL) NATIONAL CERTIFICATE (VOCATIONAL) SUBJECT GUIDELINES ELECTRICAL PRINCIPLES AND PRACTICE NQF Level 4 September 2007 ELECTRICAL PRINCIPLES AND PRACTICE LEVEL 4 CONTENTS INTRODUCTION 1 DURATION AND TUITION

More information

Generator Differential Relay Electrical Apparatus

Generator Differential Relay Electrical Apparatus Generator Differential Relay Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor

More information

EET272 Worksheet Week 8

EET272 Worksheet Week 8 EET272 Worksheet Week 8 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions We will now

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt. Lab 12: The universal motor. Objective: to examine the construction of the universal motor; to determine its no-load and full-load characteristics while operating on AC; to determine its no-load and full-load

More information

Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6

Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6 Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of

More information

Everything you need for protection scheme testing

Everything you need for protection scheme testing Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full

More information

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category

More information

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt. Lab 13: Wound rotor induction motor. Objective: to examine the construction of a 3-phase wound rotor induction motor; to understand exciting current, synchronous speed and slip in this motor; to determine

More information

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Howard W. Penrose, Ph.D On behalf of ALL-TEST Pro, LLC Old Saybrook, CT Introduction Field and shop testing of

More information

PI734D - Technical Data Sheet

PI734D - Technical Data Sheet PI734D - Technical Data Sheet PI734D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

PI734B - Technical Data Sheet

PI734B - Technical Data Sheet PI734B - Technical Data Sheet PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

THREE PHASE CIRCUITS

THREE PHASE CIRCUITS THREE PHASE CIRCUITS A. PREPARATION 1. Three Phase Voltages and Systems 2. The Determination of Phase Sequence 3. Blondel's Theorem and Its Consequences 4. References B. EXPERIMENT 1. Equipment List 2.

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions: The Charging System Charging System The charging system has two essential functions: Generate electrical power to run the vehicle s electrical systems Generate current to recharge the vehicle s battery

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

FIT TIER 2 Application

FIT TIER 2 Application FIT TIER 2 Application Application Information The below information Auto-Fills from your registration information: Building Permit Application Date: Project Completion Date: Name: Address: City: State:

More information

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR 1 DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING Constructional details Types of rotors EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR PART A 1.

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

ABB PSPS Erich Steinmann; Generator control-2013

ABB PSPS Erich Steinmann; Generator control-2013 ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise

More information

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education

More information

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR INDEX NO. : M-142 TECHNICAL MANUAL FOR NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR Manufactured by : PREMIER TRADING CORPORATION (An ISO 9001:2000 Certified Company) 212/1, Mansarover Civil

More information

Single-Phase AC Synchronous Generator

Single-Phase AC Synchronous Generator ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description

More information

Three-Phase AC Power Circuits

Three-Phase AC Power Circuits Electricity and New Energy Three-Phase AC Power Circuits Student Manual 86360-F0 Order no.: 86360-00 Revision level: 10/2014 By the staff of Festo Didactic Festo Didactic Ltée/Ltd, Quebec, Canada 2010

More information

Test & Data Management Software

Test & Data Management Software Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution

More information

Earth Fault Detection Basics in Theory

Earth Fault Detection Basics in Theory Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

National Craft Assessment and Certification Program S P E C I F I C A T I O N S National Craft Assessment and Certification Program S P E C I F I C A T I O N S INDUSTRIAL ELECTRICIAN V4 ELEC26_O4 Released September 2013 Focus Statement An Industrial Electrician must be able to interpret

More information

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012 INTRODUCTION TO SYSTEM PROTECTION Hands-On Relay School 2012 CONGRATULATIONS On choosing the field of system protection. It is an exciting, challenging profession. System protection has changed considerably

More information

TDMS Test & Data Management Software

TDMS Test & Data Management Software Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

TABLE OF CONTENTS 1.0 INTRODUCTION... 2 1.1 PURPOSE... 2 1.2 DEVIATION... 2 4.0 INTERTIE PROTECTION REQUIREMENTS... 4

TABLE OF CONTENTS 1.0 INTRODUCTION... 2 1.1 PURPOSE... 2 1.2 DEVIATION... 2 4.0 INTERTIE PROTECTION REQUIREMENTS... 4 Page: 1 of 14 KEY BULLETIN POINTS: THIS GUIDE OUTLINES MINIMUM REQUIREMENTS FOR CONNECTION OF CUSTOMER-OWNED EMERGENCY AND STANDBY (ESG) TO THE GEORGIA POWER COMPANY (GPC) DISTRIBUTION SYSTEM. THESE ARE

More information

8010-55 Basic Renewable Energy Training System

8010-55 Basic Renewable Energy Training System 8010-55 Basic Renewable Energy Training System LabVolt Series Datasheet Festo Didactic en 220 V - 50 Hz 01/2016 Table of Contents General Description 2 Courseware 3 Modular Design Approach 4 Features &

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

3468-00 Lighting and Fire Alarm Training System Add-On

3468-00 Lighting and Fire Alarm Training System Add-On 3468-00 Lighting and Fire Alarm Training System Add-On LabVolt Series Datasheet Festo Didactic en 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Additional Equipment

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component Lista Dei Simboli Dei Circuiti Per i Componenti Elettronici Wires & Connections Wire Wires joined Wires not joined To pass current very easily from one part of a circuit to another. A 'blob' should be

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

8 Speed control of Induction Machines

8 Speed control of Induction Machines 8 Speed control of Induction Machines We have seen the speed torque characteristic of the machine. In the stable region of operation in the motoring mode, the curve is rather steep and goes from zero torque

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Federal Wage System Job Grading Standards for Electric Power Controlling, 5407. Table of Contents

Federal Wage System Job Grading Standards for Electric Power Controlling, 5407. Table of Contents Federal Wage System Job Grading Standards for Electric Power Controlling, 5407 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 SPECIAL ADDITIONAL RESPONSIBILITIES...

More information

SYNCHRONOUS MACHINES

SYNCHRONOUS MACHINES SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical

More information

Power Plant Electrical Distribution Systems

Power Plant Electrical Distribution Systems PDH Course E184 Power Plant Electrical Distribution Systems Gary W Castleberry, PE 2008 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com

More information

UCI274C - Technical Data Sheet

UCI274C - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

PM734F - Technical Data Sheet Winding 28

PM734F - Technical Data Sheet Winding 28 - Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

UCI274H - Technical Data Sheet

UCI274H - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE INTRODUCTION In all kinds of manufacturing, it is very common to have equipment that has three phase motors for doing different

More information

Synchronous motor. Type. Non-excited motors

Synchronous motor. Type. Non-excited motors Synchronous motor A synchronous electric motor is an AC motor in which the rotation rate of the shaft is synchronized with the frequency of the AC supply current; the rotation period is exactly equal to

More information

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION ÿþ üûúùø öõöôùóùõò CT Dimensioning DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION Application note GER3973 1 CT Dimensioning ÿþ üûúùø öõöôùóùõò GER-3973 Application note ÿþ üûúùø öõöôùóùõò

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

First Year (Electrical & Electronics Engineering)

First Year (Electrical & Electronics Engineering) Z PRACTICAL WORK BOOK For The Course EE-113 Basic Electrical Engineering For First Year (Electrical & Electronics Engineering) Name of Student: Class: Batch : Discipline: Class Roll No.: Examination Seat

More information

Pilot-wire differential relay for lines with two or more terminals

Pilot-wire differential relay for lines with two or more terminals Pilot-wire differential relay for lines with two or more terminals Page 1 Issued: March 2003 Revision: A Data subject to change without notice Pilot-wire differential relay with RXHL 401 Features Phase

More information

Current Transformers

Current Transformers Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide

More information

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE) GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE) Matthew Theriault Designer Hindle Power Inc. Easton, PA SCOPE AND PURPOSE OF THE PAPER Why do we bother to monitor

More information

Occupational Profile: Electrical & Electronics Engineering Technician

Occupational Profile: Electrical & Electronics Engineering Technician Occupational Profile: Electrical & Electronics Engineering Technician A competent Electrical & Electronics Engineering Technician should be able to demonstrate the following skills and competences: 1.

More information