1 FIT TIER 2 Application Application Information The below information Auto-Fills from your registration information: Building Permit Application Date: Project Completion Date: Name: Address: City: State: Zip Code: Daytime Phone: Evening/Cell Phone: Fax: Address Applicant Information Is Applicant owner of Generating Facility? Yes No

2 If NO is picked on first page of application the below information will need to be completed: If YES is picked on the first page of the application the below information will be Auto-Filled. Owner of Generating Facility (required) Owner's First Name: (required) Owner's Last Name: (required) Address: (required) City: (required) State: (required) Zip Code: (required) Daytime Phone: (required) Evening/Cell Phone: Fax: (required) Address: Continue Back Once CONTINUE is chosen from the Owner of Generating Facility page: Generating Facility Information Is Generating Facility at owner location? Yes No

3 If NO is picked on the Generating Facility Information page of application the below information will need to be completed: If YES is picked on the Generating Facility Information page of the application SOME information will be Auto-Filled. Generating Facility Information (required) Tax Map Key: ( n-n-n-nnn-nnn ) (required) Electric Service Account #: Note: If this location has no service, enter for the Electric Service Account # (required) Address: (required) City: (required) State: (required) Zip Code: (required) Daytime Phone: (required) Evening/Cell Phone: (required) Fax: (required) Address: Generator Qualifications AUTO-FILL Technology: (For Solar/PV only) PV Array DC Rated Output in kw: (For Solar/PV only) PV Array AC Rated Output in kw: Maximum Site Load without Generator Capability in kw Maximum Generator Capability in kw: Minimum Site Load without Generation in kw: (required) Maximum Design Capacity [manufacturer's inverter rating, or nameplate rating if there is no inverter] in kw AC: (Between 20 and 500) Annual Energy Production of Generating Facility in kwh: Annual Energy Exported through Point of Common Coupling in kwh:

4 Generator Technical Information Seller must not modify or add to the Generating Facility without notification and the prior written consent of the Company Type of Generator: Synchronous Induction Inverter-Based Generating Facility Generator (or solar collector) Manufacturer, Model Name and Number: (A copy of Generator Nameplate and Manufacturer's Specification Sheet must also be submitted) Operating Power Factor: Nameplate rating in kw: Fault Current Contribution of Generator in Amps: Inverter Manufacturer, Model Name and Number (if used): (A copy of Inverter Nameplate and Manufacturer's Specification Sheet must also be submitted) Operating Power Factor: Rating in kw: Number of Starts Per Day: Maximum Starting kva: UF Trip Setting: UF Time Delay (Secs): Generator Grounding Method: Effectively Grounded Resonant Grounded Low-Inductance Grounded High-Resistance Grounded Low-Resistance Grounded Ungrounded Generator Characteristic Data (for rotating machines): (Not needed if Generator Nameplate and Manufacturer's Specification Sheet are provided) Direct Access Synchronous Reactance, X d : Direct Access Transient Reactance, X' d : Direct Access Subtransient Reactance, X'' d : Negative Sequence Reactance: Zero Sequence Reactance: KVA Base: Inertia Constant, H:

5 Excitation Response Ratio: Direct Access Open-Circuit Transient Time Constant, T'do: Direct Access Open-Circuit Subtransient Time Constant, T''do: Interconnecting Equipment Technical Data (to the extent owned by Seller) Will an interposing transformer be used between the generator and the point of interconnection? Yes No Transformer Data: (A copy of transformer Nameplate and Manufacturer's Test Report may be substituted) Size in KVA: Transformer Primary Voltage: Primary Transformer Delta Wye Wye Grounded Transformer Secondary Voltage: Delta Wye Wye Grounded Transformer Impedance in %: on KVA Base: Transformer Fuse Data: (Submit a copy of fuse manufacturer's Minimum Melt and Total Clearing Time-Current Curves) At: Size: Speed: Primary Voltage Secondary Voltage Transformer Protection (if not fuse): Please describe: Interconnecting Circuit Breaker (if applicable): (A copy of circuit breaker's Nameplate and Specification Sheet must also be submitted) Continuous Load Rating in Amps: Interrupting Rating in Amps: Trip Speed in Cycles: Circuit Breaker Protective Relays (if applicable): (Submit a copy of any proposed Time-Overcurrent Coordination Curves)

6 Current Transformer Data (if applicable): (Submit a copy of Manufacturer's Excitation & Ratio Correction Curves) Accuracy Class: Proposed Ratio Connection: /5 Accuracy Class: Proposed Ratio Connection: /5 Generator Disconnect Switch: A generator disconnect device (isolation device) must be installed with features as described in the FIT Interconnection Standards And Technical Requirements. Catalog No: Rated Volts: Rated Amps:

7 Single or 3 Phase: Mounting Location: General Technical Information 2 OF THE 3 FOLLOWING QUESTIONS WILL BE SHOWN: (What questions will depend on the previously entered information.) Submit a copy of site single-line diagram showing configuration and interconnection of all equipment, current and potential circuits and protection and control schemes. Do you have a single line diagram available? Submit a copy of site relay list and trip scheme, which shall include all protection, synchronizing and auxiliary relays that are required to operate the Facility in a safe and reliable manner. Do you have a Relay List and Trip Scheme available? Yes No Submit a copy of site three-line diagram (if Facility is greater than or equal to 30 kw) showing potential transformer and current transformer ratios, and details of the Facility's configuration, including relays, meters, and test switches. Do you have a three line diagram available? If a Single Line Diagram is not available at this time, one must be completed by your engineer/contractor and uploaded to the SINGLE LINE DIAGRAM folder on your "MY FIT DOCS" Page. Note: Generating and interconnection systems must be compliant with all applicable safety and performance standards. The customer is responsible for having all work performed by a licensed electrical contractor before the Company installs the necessary meter. The Company reserves the right to require additional information, as necessary, to determine the eligibility of the Applicant's project for the FIT program. Yes Yes No No Submit Cancel Back

Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6

Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6 Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of

More information

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection

More information

South Carolina Interconnection Request Application Form

South Carolina Interconnection Request Application Form South Carolina Interconnection Request Application Form INTERCONNECTION UTILITY INFORMATION Utility: Designated Utility Contact: Mailing Address: Important Note: An Interconnection Request Application

More information

Legal Name of the Customer (or, if an individual, individual's name):

Legal Name of the Customer (or, if an individual, individual's name): Instructions An Interconnection Customer who requests a Utah Public Service Commission jurisdictional interconnection must submit this Interconnection Request by hand delivery, mail, or delivery service

More information

Physical Address: City: State: Zip Code:

Physical Address: City: State: Zip Code: Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (For Small Generator Facilities with Electric Nameplate Capacities of 10 MW and less) Applicant Contact

More information

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category

More information

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (See ARSD chapter 20:10:36 for the requirements for a Tier 2, Tier 3, or Tier 4 Interconnection.) Applicant/Interconnection

More information

Rule 5.500 Fast Track Analysis for National Life Insurance Co.

Rule 5.500 Fast Track Analysis for National Life Insurance Co. Rule 5.500 Fast Track Analysis for National Life Insurance Co. For a 500 kw Solar array to be located at 155 Northfield Street in Montpelier, Vermont Green Mountain Power Pam Allen Date: 5/31/13 SECTION

More information

PV and Inverter based DER Ground Referencing Requirements and Sample Calculations

PV and Inverter based DER Ground Referencing Requirements and Sample Calculations PV and Inverter based DER Ground Referencing Requirements and Sample Calculations Scope This document lists technical requirements, and provides sample calculations, for ground referencing of inverter

More information

ELECTRIC SAMPLE FORM Sheet 1 Rule 21 Exporting Generator Interconnection Request

ELECTRIC SAMPLE FORM Sheet 1 Rule 21 Exporting Generator Interconnection Request Pacific Gas and Electric Company San Francisco, California U 39 Revised Cal. P.U.C. Sheet No. 32724-E Cancelling Original Cal. P.U.C. Sheet No. 32052-E* ELECTRIC SAMPLE FORM 79-1145 Sheet 1 Rule 21 Exporting

More information

CitiPower Pty and Powercor Australia LTD. Appendix A: Embedded Generation - Preliminary information details for assessment.

CitiPower Pty and Powercor Australia LTD. Appendix A: Embedded Generation - Preliminary information details for assessment. CitiPower Pty and Powercor Australia LTD Appendix A: Embedded Generation - Preliminary information details This document provides details of the minimum information required to be submitted to CitiPower

More information

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP Grid Interconnection & Contract Development Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP Submittal Instructions Prior to submitting your application and

More information

HOLYOKE GAS & ELECTRIC DEPT S Distributed Generation Policy Effective: September 18, 2012

HOLYOKE GAS & ELECTRIC DEPT S Distributed Generation Policy Effective: September 18, 2012 HOLYOKE GAS & ELECTRIC DEPT S Distributed Generation Policy Effective: September 18, 2012 1. Introduction The objective of this Policy is to promote green technologies in the City of Holyoke by accommodating

More information

A Grounding Bank Design Guideline To Meet The Effective Grounding Requirements Per IEEE P Sizing Methodology Using Solectria Inverters

A Grounding Bank Design Guideline To Meet The Effective Grounding Requirements Per IEEE P Sizing Methodology Using Solectria Inverters A Grounding Bank Design Guideline To Meet The Effective Grounding Requirements Per IEEE P1547.8 Sizing Methodology Using Solectria Inverters 1. Background Solectria prepared this document to aid the PV

More information

Please Refer to Attached Sample Form

Please Refer to Attached Sample Form Pacific Gas and Electric Company San Francisco, California U 39 Revised Cal. P.U.C. Sheet No. 37177-E Cancelling Revised Cal. P.U.C. Sheet No. 37020-E Electric Sample Form No. 79-1174 Sheet 1 Rule 21 Interconnection

More information

TERMS AND CONDITIONS

TERMS AND CONDITIONS Virginia Electric and Power Company TERMS AND CONDITIONS XXIV. GENERATOR INTERCONNECTION STANDARD Electric generator interconnection service includes only the ability to interconnect an electric generator

More information

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer A Short Circuit analysis is used to determine the magnitude of short

More information

Interconnection of Generators to EDI s Distribution System

Interconnection of Generators to EDI s Distribution System Interconnection of Generators to EDI s Distribution System May 22, 2002 This document sets forth the guidelines for connecting a power producing facility to the Alberta Interconnected Electric System through

More information

Ground Fault Protection

Ground Fault Protection GE Energy Industrial Solutions Ground Fault Protection Digital Specification Program Latin America Ground Fault. I. Introduction In the electrical systems always exists the possibility of having shutdowns

More information

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the

More information

Dakota Energy Cooperative, Inc. POLICY STATEMENT

Dakota Energy Cooperative, Inc. POLICY STATEMENT Dakota Energy Cooperative, Inc. POLICY STATEMENT Subject: Member Owned Small Renewable Energy Policy No. 57 Rate and Interconnection Requirements Issue Date: May 21, 2008 Revised Date: December 16, 2014

More information

Preliminary Enquiry Form Non-Registered Embedded Generator (Capacity less than 5 MW Chapter 5A)

Preliminary Enquiry Form Non-Registered Embedded Generator (Capacity less than 5 MW Chapter 5A) This Preliminary Enquiry Form will form the basis of the Application to Connect. 1. Connection Applicant (Embedded Generating Unit Owner/Proponent) 1.1 Business name: 1.2 ABN: 1.3 Contact name: 1.4 Address:

More information

MicroFIT Connection Application Guidelines

MicroFIT Connection Application Guidelines MicroFIT Connection Application Guidelines These guidelines serve to ensure the efficient processing and implementation of your project. Please read and follow them carefully and completely in order to

More information

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM TECHNICAL DATA SHEET FOR SYNCHRONOUS MACHINES IN THE PG&E SYSTEM FOR POWER FLOW, TRANSIENT STABILITY, AND FAULT

More information

Neutral Connections and Effective Grounding

Neutral Connections and Effective Grounding Neutral Connections and Effective Grounding Introduction Neutral connections and effective grounding are not recommended to mitigate temporary overvoltage when using listed photovoltaic inverters. Millions

More information

Inverter / Charger Installation General Operations and AC and DC Connections

Inverter / Charger Installation General Operations and AC and DC Connections Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

TABLE OF CONTENTS 1.0 INTRODUCTION... 2 1.1 PURPOSE... 2 1.2 DEVIATION... 2 4.0 INTERTIE PROTECTION REQUIREMENTS... 4

TABLE OF CONTENTS 1.0 INTRODUCTION... 2 1.1 PURPOSE... 2 1.2 DEVIATION... 2 4.0 INTERTIE PROTECTION REQUIREMENTS... 4 Page: 1 of 14 KEY BULLETIN POINTS: THIS GUIDE OUTLINES MINIMUM REQUIREMENTS FOR CONNECTION OF CUSTOMER-OWNED EMERGENCY AND STANDBY (ESG) TO THE GEORGIA POWER COMPANY (GPC) DISTRIBUTION SYSTEM. THESE ARE

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

HCI634H - Technical Data Sheet

HCI634H - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process

Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process Presented by: Marianne Mannschreck Date: Welcome A Look at the Net Energy Metering

More information

AUSTIN ENERGY INTERCONNECTION GUIDE FOR CUSTOMER-OWNED POWER PRODUCTION FOR FACILITIES UP TO 10MW A INTERCONNECTION CLASSIFICATIONS...

AUSTIN ENERGY INTERCONNECTION GUIDE FOR CUSTOMER-OWNED POWER PRODUCTION FOR FACILITIES UP TO 10MW A INTERCONNECTION CLASSIFICATIONS... AUSTIN ENERGY INTERCONNECTION GUIDE FOR CUSTOMER-OWNED POWER PRODUCTION FOR FACILITIES UP TO 10MW TABLE OF CONTENTS PAGE INTRODUCTION... 4 A INTERCONNECTION CLASSIFICATIONS... 5 B. APPLICATION PROCESS

More information

Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva

Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva Issued: August 2009 SIZED UP TO 100 KVA TABLE OF CONTENTS 1.0 Introduction... 1 1.1 Applicability... 1 1.2 Definitions...

More information

ARC Flash Hazard Analysis and Mitigation. IEEE Press Series on Power Engineering

ARC Flash Hazard Analysis and Mitigation. IEEE Press Series on Power Engineering Brochure More information from http://www.researchandmarkets.com/reports/2330613/ ARC Flash Hazard Analysis and Mitigation. IEEE Press Series on Power Engineering Description: Up to date analysis methodologies

More information

UCI274E - Technical Data Sheet

UCI274E - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

Solar Power Plant Design and Interconnection

Solar Power Plant Design and Interconnection Solar Power Plant Design and Interconnection Wind & Solar Super Session July 27, 2011 E.H. Camm, S.E. Williams S&C Electric Company Outline Introduction Utility-scale PV power plant Grounding Reactive

More information

Solar Power Installation Application

Solar Power Installation Application Solar Power Installation Application Application for Interconnection This Form must be filled out and submitted to Logan City Light and Power Department and given authorization to proceed PRIOR to installing

More information

PROTECTION CONSIDERATIONS FOR COMBUSTION GAS TURBINE STATIC STARTING

PROTECTION CONSIDERATIONS FOR COMBUSTION GAS TURBINE STATIC STARTING PROTECTION CONSIDERATIONS FOR COMBUSTION GAS TURBINE STATIC STARTING Working Group J-2 of the Rotating Machinery Subcommittee, Power System Relay Committee Chairperson: Mike Reichard Vice Chairperson:

More information

Residential Solar Service Agreement (RSSA) Customer Sited Solar Photovoltaic Systems

Residential Solar Service Agreement (RSSA) Customer Sited Solar Photovoltaic Systems Residential Solar Service Agreement (RSSA) Customer Sited Solar Photovoltaic Systems This Agreement is made and entered into this day of, 20, ( Effective Date ) by and between the Orlando Utilities Commission

More information

Modeling and Testing of Unbalanced Loading and Voltage Regulation

Modeling and Testing of Unbalanced Loading and Voltage Regulation National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Modeling and Testing of Unbalanced

More information

PI734F - Technical Data Sheet

PI734F - Technical Data Sheet PI734F - Technical Data Sheet PI734F SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

AS BUILT DOCUMENTATION CHECKLIST FOR GENERATOR INTERCONNECTIONS

AS BUILT DOCUMENTATION CHECKLIST FOR GENERATOR INTERCONNECTIONS AS BUILT DOCUMENTATION CHECKLIST FOR GENERATOR INTERCONNECTIONS Requirement: Per Article 5 of the Large Generator Interconnection Agreement and Article 2 of the Small Generator Interconnection Agreement

More information

HCI634G - Technical Data Sheet

HCI634G - Technical Data Sheet HCI634G - Technical Data Sheet HCI634G SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

DIVISION 26 ELECTRICAL SECTION SHORT-CIRCUIT/COORDINATION/ARC FLASH STUDY

DIVISION 26 ELECTRICAL SECTION SHORT-CIRCUIT/COORDINATION/ARC FLASH STUDY DIVISION 26 ELECTRICAL PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Short-Circuit, Protective Device Coordination and Arc Flash Studies 2. Labels 1.02 REFERENCES A. Institute of Electrical and Electronics

More information

UCI274C - Technical Data Sheet

UCI274C - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

Considerations for reliable closed transition transfer switches

Considerations for reliable closed transition transfer switches Our energy working for you. TM Power topic #5823 Technical information from Cummins Power Generation Considerations for reliable closed transition transfer switches White Paper By Rich Scroggins, Technical

More information

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance WHITE PAPER Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance Overview Enphase has developed a new microinverter family that includes the M250 and new

More information

UCI274H - Technical Data Sheet

UCI274H - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

Voltage Transformers. VT Types

Voltage Transformers. VT Types Voltage Transformers VT - Voltage Transformer, also know as Potential Transformer (PT) CVT - Capacitive Voltage Transformer also know as CCVT (Capacitive Coupled VT) BPD - Bushing Potential Device also

More information

SPECIFICATION COG-2007

SPECIFICATION COG-2007 Cleco Power LLC SPECIFICATION COG-2007 FOR PARALLEL OPPERATION OF CUSTOMER-OWNED GENERATION ON CLECO S ELECTRICAL SYSTEM Revised: March 7, 2014 CONTENTS ITEM NO. TITLE PAGE NO. 1.0 Scope 3 2.0 Policy On

More information

Technically Speaking. 1. Basic Power. 2. Why Correct Power Factor. 3. Power Factor Correction Capacitors

Technically Speaking. 1. Basic Power. 2. Why Correct Power Factor. 3. Power Factor Correction Capacitors No. 0011 Industrial Products Division 4-20-2012 Capacitors for Power Factor Correction 1. Basic Power In any power system, there are three components that effect connected equipment: real, reactive, and

More information

PI734D - Technical Data Sheet

PI734D - Technical Data Sheet PI734D - Technical Data Sheet PI734D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

O.C. & S.C. TEST ON 1 PHASE TRANSFORMER

O.C. & S.C. TEST ON 1 PHASE TRANSFORMER INDEX NO. : M-74 TECHNICAL MANUAL FOR O.C. & S.C. TEST ON 1 PHASE TRANSFORMER Manufactured by : PREMIER TRADING CORPORATION (An ISO 9001:2000 Certified Company) 212/1, Mansarover Civil Lines, MEERUT. Phone

More information

PI734B - Technical Data Sheet

PI734B - Technical Data Sheet PI734B - Technical Data Sheet PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

Installation Instructions. Allen-Bradley 1336/1336VT 1336 PLUS/PLUS II/FORCE/IMPACT Chopper Module -WA070, WB035 & WC035 -WA115, WB110 & WC085

Installation Instructions. Allen-Bradley 1336/1336VT 1336 PLUS/PLUS II/FORCE/IMPACT Chopper Module -WA070, WB035 & WC035 -WA115, WB110 & WC085 Installation Instructions Allen-Bradley 1336/1336VT 1336 PLUS/PLUS II/FORCE/IMPACT Chopper Module Cat. Nos. 1336 Table of Contents -WA018, WB009 & WC009 -WA070, WB035 & WC035 -WA115, WB110 & WC085 What

More information

TECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION. Micro Generation & Small Generation, 3-phase, less than 30 kw

TECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION. Micro Generation & Small Generation, 3-phase, less than 30 kw TECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION Micro Generation & Small Generation, 3-phase, less than 30 kw i COPYRIGHT 2010 HYDRO ONE NETWORKS INC. ALL RIGHTS RESERVED ii LIMITATION

More information

Application of Four-Pole Circuit Breakers within Data Centers

Application of Four-Pole Circuit Breakers within Data Centers Application of Four-Pole Circuit Breakers within Data Centers December 2013/AT324 by Frank Waterer, Fellow Engineer, Schneider Electric Engineering Services Make the most of your energy SM Revision #1

More information

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section

More information

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service

More information

Request for Proposals for Photovoltaic System Installation

Request for Proposals for Photovoltaic System Installation Request for Proposals for Photovoltaic System Installation Presented by: Prepared by: Location: Contact: Date: Capitol Hill Housing Foundation Bonneville Environmental Foundation, Renewable Energy Group

More information

UCI224F - Winding 17. Technical Data Sheet

UCI224F - Winding 17. Technical Data Sheet - Winding 17 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant section of other international standards such as BS5000,

More information

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov PHOTOVOLTAIC PERMITTING GUIDELINES The information provided in this document is general and is intended only as a

More information

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet LV 804 S WDG 12 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections

More information

SHORT CIRCUIT STUDIES

SHORT CIRCUIT STUDIES 4 SHORT CIRCUIT STUDIES 4.1 INTRODUCTION In a power system short circuits occur once in a while due to lightning, flash over due to polluted insulation, falling of tree branches on the overhead system,

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

PM734F - Technical Data Sheet Winding 28

PM734F - Technical Data Sheet Winding 28 - Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

Electrical Power & Machines

Electrical Power & Machines d.c. Machines a.c. Single & Three Phase Machines Dissectible Machines Single & Three phase Transformers Measurement & Control Power Electronics Conventional & Virtual (PC based) Instrumentation Renewable

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

ELECTRICAL TRAINING 7 DAYS D.C. 1.0 Electron Theory, Voltaic Cells. And Electromagnetism. Materials 3.0 Resistances In Series And Parallel.

ELECTRICAL TRAINING 7 DAYS D.C. 1.0 Electron Theory, Voltaic Cells. And Electromagnetism. Materials 3.0 Resistances In Series And Parallel. Num TITLE TABLE OF CONTENT OBJECTIVES DURATION UNIT E-01 FUNDAMENTALS OF 1.0 Electron Theory, Voltaic Cells Describe The Atomic D.C. And Electromagnetism. Structure And Its Influence 2.0 D.C. Circuits

More information

N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS

N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS N.J.A.C. 14:8-4 NET METERING FOR CLASS I RENEWABLE ENERGY SYSTEMS 14:8-4.1 Scope This subchapter sets forth net metering requirements that apply to electric power suppliers, basic generation service providers

More information

Power Line Harmonics. and Installation Considerations. For AC and DC Drives

Power Line Harmonics. and Installation Considerations. For AC and DC Drives Power Line Harmonics and Installation Considerations For AC and DC Drives Doc # October 10, 2004 Page 1 of 14 Contents POWER LINE HARMONICS AND INSTALLATION CONSIDERATIONS FOR AC AND DC DRIVES... 3 DC

More information

MINNESOTA VALLEY ELECTRIC COOPERATIVE DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS FOR INVERTER CONNECTED SYSTEMS RATED 40KW OR LESS,

MINNESOTA VALLEY ELECTRIC COOPERATIVE DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS FOR INVERTER CONNECTED SYSTEMS RATED 40KW OR LESS, MINNESOTA VALLEY ELECTRIC COOPERATIVE DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS FOR INVERTER CONNECTED SYSTEMS RATED 40KW OR LESS, TABLE OF CONTENTS 1. Introduction 3 2. References 6 3. Interconnection

More information

BCI184E - Technical Data Sheet

BCI184E - Technical Data Sheet BCI184E - Technical Data Sheet BCI184E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Lecture 5: Transformers(continued)

Lecture 5: Transformers(continued) Lecture 5: Transformers(continued) Equivalent circuit of a transformer Figure (1) shows an equivalent circuit of a transformer. R 1 and R 2 represent the resistances of the primary and secondary windings

More information

DAKOTA ELECTRIC ASSOCIATION DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS FOR INVERTER CONNECTED SYSTEMS RATED LESS THAN 40KW,

DAKOTA ELECTRIC ASSOCIATION DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS FOR INVERTER CONNECTED SYSTEMS RATED LESS THAN 40KW, DAKOTA ELECTRIC ASSOCIATION DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS FOR INVERTER CONNECTED SYSTEMS RATED LESS THAN 40KW, TABLE OF CONTENTS 1. Introduction 3 2. References 6 3. Interconnection

More information

A Common Cure for Harmonics: ABB Ultra Low Harmonic Drives

A Common Cure for Harmonics: ABB Ultra Low Harmonic Drives Matthew LaRue, ABB Drives Product Manager Philadelphia District, Baldor of Philadelphia A Common Cure for Harmonics: ABB Ultra Low Harmonic Drives October 21, 2013 Slide 1 Session Goals Understand what

More information

Apprentice Electrical Technician Test (ETT) Preparation Guide

Apprentice Electrical Technician Test (ETT) Preparation Guide Apprentice Electrical Technician Test (ETT) Preparation Guide APPRENTICE ELECTRICAL TECHNICIAN TEST (ETT) About the Test There are 40 questions with a maximum time limit of three hours. This is a closed

More information

OVER THE COUNTER ELECTRICAL PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS

OVER THE COUNTER ELECTRICAL PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS OVER THE COUNTER ELECTRICAL PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS Contractors can apply for an Over The Counter (OTC) permit where the PV system meets the requirements listed in this

More information

Photovoltaic Incentive Program

Photovoltaic Incentive Program Incentive type: Utility Rebate Program Eligible Technologies: Photovoltaic (PV) Photovoltaic Incentive Program Applicable Sector: Residential/Commercial/Industrial/Municipal System Maximum capacity: 20

More information

Belleville Fire Hall/Headquarters and Emergency Operations Centre Belleville, Ontario Page 1 of 6

Belleville Fire Hall/Headquarters and Emergency Operations Centre Belleville, Ontario Page 1 of 6 Belleville, Ontario Page 1 of 6 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

Title: Australian Guidelines for grid connection of energy systems via inverters.

Title: Australian Guidelines for grid connection of energy systems via inverters. Title: Australian Guidelines for grid connection of energy systems via inverters. Foreword 28 April, 1998 The guidelines have been developed by a group of utility, photovoltaic and inverter industry experts

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Rocky Mountain Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system

More information

GROUNDING AND GROUND FAULT PROTECTION OF MULTIPLE GENERATOR INSTALLATIONS ON MEDIUM-VOLTAGE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

GROUNDING AND GROUND FAULT PROTECTION OF MULTIPLE GENERATOR INSTALLATIONS ON MEDIUM-VOLTAGE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS GROUNDING AND GROUND FAULT PROTECTION OF MULTIPLE GENERATOR INSTALLATIONS ON MEDIUM-VOLTAGE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS PART 3: PROTECTION METHODS An IEEE/IAS Working Group Report [Working

More information

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering Title 20 PUBLIC SERVICE COMMISSION Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES Chapter 02 Engineering Authority: Public Utility Companies Article, 2-121, 5-101 and 5-303, Annotated Code of Maryland.

More information

Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller

Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller A fee of $0.00 must accompany this application Date: Section 1: Customer Information Section 2: Engineering firm

More information

Rotary Phase Converters

Rotary Phase Converters FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON

More information

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114. Generation Interconnection System Impact Study Report For PJM Generation Interconnection Request Queue Position X1-114 Sandyston January 2012 Preface The intent of the System Impact Study is to determine

More information

OVERCURRENT COORDINATION GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

OVERCURRENT COORDINATION GUIDELINES FOR INDUSTRIAL POWER SYSTEMS The Electrical Power Engineers Qual-Tech Engineers, Inc. 201 Johnson Road Building #1 Suite 203 Houston, PA 15342-1300 Phone 724-873-9275 Fax 724-873-8910 www.qualtecheng.com OVERCURRENT COORDINATION GUIDELINES

More information

Substation Design. Detail design of substation. Consider open loop MV network as an example. source 1 source 2. NC NC or NO main MV switchboard

Substation Design. Detail design of substation. Consider open loop MV network as an example. source 1 source 2. NC NC or NO main MV switchboard Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV

More information

Directional Ground and Sensitive Ground Fault Settings, Cooper Form 5 and Form 6 Controls and Idea Relay, Three-Wire Distribution Systems

Directional Ground and Sensitive Ground Fault Settings, Cooper Form 5 and Form 6 Controls and Idea Relay, Three-Wire Distribution Systems Directional Ground and Sensitive Ground Fault Settings, Cooper Form 5 and Form 6 Controls and Idea Relay, Three-Wire Distribution Systems Bruce Meyer Cooper Power Systems ii Directional Ground and Sensitive

More information

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile Michael Coddington National Renewable Energy Laboratory Golden, Colorado,

More information

ACCURACY OF POTENTIALTRANSFORMERS

ACCURACY OF POTENTIALTRANSFORMERS 8 VOLTAGE TRANSFORMERS Two types of voltage transformer are used for protective-relaying purposes, as follows: (1) the "instrument potential transformer," hereafter to be called simply "potential transformer,"

More information

Power System Analysis Prof. A.K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur. Lecture - 27 Sequence Networks

Power System Analysis Prof. A.K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur. Lecture - 27 Sequence Networks (Refer Slide Time: 00:52) Power System Analysis Prof. A.K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture - 27 Sequence Networks Welcome to lesson 27 on Power

More information

Standing Seam Spec Option BIPV Section 07400

Standing Seam Spec Option BIPV Section 07400 Standing Seam Spec Option BIPV Section 07400 A. Standing Seam Metal Roof Manufacturer and Contractor shall be responsible for manufacturing and installing BIPV Standing Seam Roof Panel per drawings for

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information