Test & Data Management Software
|
|
|
- Cecil Green
- 10 years ago
- Views:
Transcription
1 Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution TDMS is a powerful software package providing data management for acceptance and maintenance testing activities. Electrical apparatus data and test results are saved in the TDMS database for historical results analysis. TDMS software organizes test data and results for the majority of electrical apparatus tested with ISA test sets and related software. TDMS software controls and provides data acquisition from all ISA Test:. DRTS 66, DRTS 6, BER 3, DRTS, DRTS 3 and ART 3 - Relay and Energy meters test sets.. T1000, T2000 and T Primary and Secondary injection test sets.. CBA 1000 and CBA Circuit Breaker analyzers.. BTS 100, BTS Battery load units. TDMS software is a powerful database. It allows to create an electrical network with substations, feeders and the majority of electrical apparatus, such as:. Relays. Instrument transformers. Power transformers. Circuit Breakers. Energy Meters. Transducers. Power Quality Meters. Ground Grids TDMS Test & Data Management Software is the Integrated testing solution to perform any substation apparatus commissioning and maintenance
2 TDMS Report Editor TDMS has a built-in Report Editor that allows to generate professional test report for a single test object, for a group of tested devices or for an entire substation. It can create customized report or use standard forms. TDMS Tests report can be exported in MS Office (Word and Excel), PDF or RTF formats. TDMS Data base TDMS Reports TDMS is the control platform to run all ISA test software. Test programs, calibration, firmware, software upgrade and languages are all managed from TDMS. TDMS Control Platform 2
3 Test & Data Management So f t w a r e TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries TDMS - Testing Protective Relays TDMS is a software package to be used with all the automatic test systems manufactured by ISA TDMS is a powerful software package for testing:. Protective relays in transmission, distribution and power generation;. Watt-hour meters;. Transducers;. Meters;. Power quality meters. TDMS runs within Microsoft Windows 98, 2000, XP and Vista. surge arresters OUT OF STEP - POWER SWING SYNCHROCHECK RELAYS O/C Relays TEST PLAN EDITOR DIFFERENTIAL RELAYS DIRECTIONAL RELAYS TDMS V,F,P RELAYS LOSS OF FIELD RELAYS PLAYING BACK TRANSIENT SIGNAL COMTRADE R.PRO DISTANCE RELAYS 3
4 Relay Application description The TDMS software platform allows the user to select easily and quickly the most appropriate software package for the required application. TDMS test software uses an open architecture easily expandable with additional software modules at any time. IEC61850 Interface - Relay testing with Ethernet -based substation communication protocol. By means of a dedicated hardware and the TDMS software, ISA DRTS 6 can expand his testing capabilities by handling those IEC61850 messages.. Test of Distance relays with simulation of all type of faults: single phase, two phase, two phase to ground; three phase;. Report Manager allows test report customization to user requirements; results are exported in Windows formats. Comtrade Module: Playing back transient signals and waveform generation. Playing back transient signal from digital fault recorders and numerical relays;. Analysis of relay operating time;. Graphical view and replay of analog and binary signals;. Impedance locus display; TDMS Package can be used to test any protective relays in: Power Generation Plants; Distribution network; Transmission network; Industry. Comtrade: Playing back transient signals. New manual control virtual front panel. Manual control module has the following main characteristics:. Intuitive graphical user interface;. Virtual Front Panel control;. Graphical Vector control;. Ramp Test: sequence of tests with ability to ramp any parameter up or down at the same time;. Threshold test: automatic determination of a threshold (current, voltage, frequency, phase angle);. Rate of change (gradient) tests of frequency, voltage, current, phase-angle and V dc (Dx/Dt);. Sequence editor;. Test of Distance relays with direct import of relay characteristic with RIO Format; Comtrade: Impedance locus display. Scaling, cut, copy and paste of the analog signals;. Supported file format: COMTRADE;. Test reports for printing or export in Windows.TXT or WMF format. 4
5 Test & Data Management So f t w a r e Test Plan Editor The Program Control Tab now has a new layout: Relays Test Plan and Editor; with this new features we give the user the possibility to create and run different test plans for different test applications.. Graphical definition of the nominal characteristic;. Automatic test and computing of deviation from the nominal values;. Report Manager allows test report customization to user requirements; results are exported in Windows formats. Test Plan Editor is available to create a test plan using predefined macro functions available for any type of relays. This new feature is particularly useful for testing multifunction relays. The Test Plan can be associated to any relay in TMDS Network Structure and prior execution define relay setting and characteristic. The Test Plan, can be run on a specified relay: the entire test plan can be executed and/or the user can select the macros to execute on that relay according to its needs. Finally the Test Plan can be printed and saved automatically into the TDMS database. Automatic Relays Testing in Power Transmission, Generation & Distribution The TDMS - Generation & Distribution Module is a powerful software that allows the user fully automatic testing of the main protective relays in:. Transmission networks;. Power Generation Plants;. Distribution networks;. Industry. Main characteristics:. Extremely easy to use;. Intuitive graphical user interface;. Click and test operation;. Multifunction relay test; Overcurrent relay module Graphical definition of the nominal characteristic;. Automatic test and computing of deviation from the nominal values;. Report Manager allows test report customization to user requirements; results are exported in Windows formats. TDMS Software includes the following testing modules: Differential relay module-87. Sequencer The sequencer module is a software for determining the relays operating time and the logical sequence of the event. 5
6 Sequencer. OVERCURRENT MODULE for automatic testing of OVER-CURRENT relays, including all the standard curves IEC, IEEE and IEC.. DIFFERENTIAL RELAYS MODULE-87, for automatic testing of Differential relays (transformers, generators and bus bar), with 3 and 6 currents. Swing Pro module. Harmonic generator. Directional relay module-67.. LINE DIFFERENTIAL MODULE 87-7: Automatic testing of Line differential relays; End to End testing with GPS (Global Positioning System) synchronization, using two DRTS.. DIRECTIONAL MODULE-67, for automatic testing of earth directional relays.. SYNCHRONIZING MODULE-28, for automatic testing of synchronizing devices with 3 or 6 voltages control.. SWING PRO MODULE: for testing power swing blocking and out of step function.. MULTIFUNCTION RELAYS can be tested easily creating customized test plans.. HARMONIC GENERATOR MODULE allows the creation of arbitrary harmonic waveform. Distance Relays-21 The Distance Relays-21 Module is powerful software that allows users fully automatic testing of any distance relay regardless of the type or the manufacturer in HV and EHV Transmission networks. Main characteristics:. Graphical user friendly interface;. Interactive Graphic editor of the nominal characteristic;. Automatic test and computing of deviation from the nominal values;. Sequencer Editor for creating test sequences by entering fault impedances or entering currents/voltages and phaseangle quantities;. Report Manager allows test report customization according to user requirements; results are exported in Windows formats. 6
7 Test & Data Management So f t w a r e Distance Relay-21 has the following testing features:. Graphical editor of distance relay characteristic;. Simulation of all types of faults: single phase, two phase, two phase to ground; three phase;. Click and test directly the R-X diagram of any distance relay nominal characteristic;. Automatic test of a given nominal characteristic;. Automatic search of an unknown characteristic;. End to End test by means of two synchronized ISA test sets;. Power Swing Blocking test;. Auto-recloser test;. Developing fault test;. Switch-on-to-fault test;. Fuse failure;. Direct import of the setting files from main relay manufacturers using RIO file format;. Import SET files from our old automatic test programs for distance relays written with X.TEST editor. Enhanced features: Other important features have been included to enhance the automatic test, like:. Possibility to set different earth factor for each zone: this feature was already available with other automatic test programs since more and more relays now have this feature.. Possibility to set the earth factor as RE/RL and XE/XL. Possibility to test the characteristic represented in terms of loop resistance and fault reactance (better known as Arc resistance compensation). Special distance relay test programs A large number of special test programs for the main relay manufacturers is included in our Special Distance Relays Test Program Library. Test programs for old electromechanical, solid state and numerical relays from AREVA, ASEA, ABB, ALSTOM, BBC, GE, GEC Alsthom, Mitsubishi, SEL, SIEMENS, Toshiba and VAtech are included in the library (Please ask for the detailed list of test programs). These programs ask the relay settings, draw the nominal curve and test it automatically with the Distance Relay-21 program. Distance relay-21 test program. Special distance relay module. Distance relay-21 test program. 7
8 Testing Energy Meters Trasducers and PQ Meters This package is designed for the automatic test and calibration of:. Energy meters. Transducers. Measuring instruments The Measurement Software Package consists of three test programs: Results. Results are saved in graphical and tabular form for later use;. Test reports for printing or export in Windows.TXT or.wmf format. Transducers Has been designed for testing measuring transducers:. Voltage, Current, Frequency and all Power transducers;. The software automatically computes the errors of transducers. Energy meters Allows automatic testing and calibration of energy meters according to the international standard IEC521.. Test of class 1, 0.5 or 0.2 energy meters;. Test without or with a standard meter;. Energy meter accuracy test - Load test; Transducer Test Program control panel. Energy Meter Test Program control panel. Transducer Test Program manual cotrol. Energy Meter Test Program manual control. Results. Results are saved in graphical and tabular form for later use;. Test reports for printing or export in Windows.TXT or.wmf format.. Creep test;. No-Load test;. Automatic percentage of error computation. 8
9 Test & Data Management So f t w a r e Power quality meters It allows automatic testing of power quality meters according to the international standard IEC Tested Parameters are: change in power frequency; changes in supply voltage (dips, swells, rapid voltage changes...); presence of flickers; voltage and current harmonics/interharmonics; voltage unbalance; transient voltages; and others. Harmonic content. Measurements of the Total Harmonic Distortion, and of the distortion of all harmonic components up to the 40th. Oscilloscope feature: it is possible to select the trace to be viewed, and to view it on the local display of the DRTS66. The oscilloscope can be triggered on any trace. Recording feature: it is possible to use the test set as an analog transient recorder and as a digital sequence of event recorder. Extended triggering capability: positive and negative trigger thresholds and ROC thresholds on any of the voltage or current inputs, and also on any of the computed parameters. Pqmeter. Test Program control panel. Transcope Software Module This software module is an option for DRTS66. This option is to be specified at order. With this option the 10 binary inputs of the DRTS66 can be configured as 10 analog voltage inputs and to act as a:. Three phase voltage and current (with external clamp or shunts), phase angle, wattmeter, frequency and harmonic meter;. Oscilloscope;. Analog Transient recorder;. Sequence of event recorder. The Transcope functions can be used during any other test function of the DRTS66. Measurement features:. Current and voltage: RMS values.. Phase angles between inputs.. Frequency.. Active, reactive and apparent power.. Energy. Programmer Software Package XTEST_ X ISA Provides an OCX application (ActiveX) that allows controlling any Automatic Relay Test Set with high level languages, such as Visual Basic, Visual C++ or any other software that supports the ActiveX technology. This is particularly useful for integrating the test set control into existing software, that includes the control of other instruments, such as meters, converters and so on. 9
10 TDMS protective relays The software performs various tasks, such as:. Download stored measures, performed on the field, and saved in the local memory of the instrument;. Open and save results in a Access Database (.MDB) format; energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters Testing CT-VT-PT Transformers TDMS CT-VT-PT Transformer and Ground Grid software module is a powerful application that provides connectivity with the instruments of the t/xx family: T1000 for relays testing, T2000 for transformer testing and the powerful substation & maintenance test set T3000. The main test application are defined as:. Relay Test Application. Transformer Test Application. Line Impedance Measurement. Ground Grid Resistance and soil resistivity TDMS - Relay Test Result For T1000 and T3000 in relay test application mode:. Real time display of the measures made by the instrument;. Possibility to draw the characteristic of the relay under test.. Perform calculation on the results.. Display and print Cartesian or Polar graphs of all combination of measures. For T2000 and T3000 in transformer test application mode:. Display and print transformer results.. Compare different CT excitation curves on the same graph. The TDMS software control also the instrument to:. Upgrade the firmware of the instrument.. Save or load the calibration values. For T1000 and T3000 in Relay test application mode:. Control the choice of internal or external complementary measures;. Save or load of instrument settings. TDMS - CT Saturation Curve Test Result TDMS - CT Test Result 10
11 Test & Data Management So f t w a r e TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters Testing Circuit Breakers TDMS - Circuit Breaker software module is a powerful application that provides connectivity with CBA 1000/CBA 2000 test set for circuit breaker analysis. The software performs various tasks, such as:. Full control of the Circuit Breaker analyzer CBA 1000/CBA Download pre-defined test plans to the CBA 1000/CBA 2000 test set.. Download test plans defined with CBA 1000/CBA 2000 to TDMS.. Download test results (timing test, coil current, transducers and microhmeter measures) stored on CBA 1000/CBA 2000 local memory. TDMS - Circuit Breaker Testing Parameters. Display channels waveforms.. Calculation on data received from CBA 1000/CBA Compare different curves on the same graph.. Enhanced measurement features for motion, speed and acceleration analysis.. Test plans and test results can be viewed, edited, saved and printed.. Test results can be exported in Word, Excel, RTF format and PDF.. Save or Upload the calibration values. TDMS - Circuit Breaker Test Result TDMS - Circuit Breaker Testing Parameters 11
12 GB - TDMS
TDMS Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
FREJA Win Software for FREJA relay testing system
Software for FREJA relay testing system A Megger Group Company Software for FREJA relay testing system In FREJA Win, the all-round General instrument program serves as a convenient, easy to understand,
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
Everything you need for protection scheme testing
Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full
Protection and Substation Automation. Training Programmes
Protection and Substation Automation Training Programmes Protection and Substation Automation Training Programme Overview The objective of the Training Program is to provide education and training to make
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
AVTS Advanced Visual Test Software, 3.3
, 3.3 AVTS Powerful, easy-to-use Microsoft Windows 2000/XP/Vista TM compatible Designed to manage all aspects of protective relay testing using the MPRT Relay Test Set Now loaded with more features and
PSS SINCAL - Overview -
PSS SINCAL - Overview - PTI Day Buenos Aires, October 19/20, 2010 Dr. Michael Schwan,, Siemens PTI (Germany) www.siemens.com/energy/power-technologies PSS SINCAL Overview Page 3 Network Calculation Software
APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES
APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES J. Ariza G. Ibarra Megger, USA CFE, Mexico Abstract This paper reviews
Primary Test Manager (PTM) Testing and management software for primary assets
Primary Test Manager (PTM) Testing and management software for primary assets The ideal tool for diagnostic testing and condition assessment The Primary Test Manager TM (PTM) is the ideal software tool
TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v1.0 2013 Spring web.itu.edu.tr/yumakk. Distance Protection
Distance Protection Announcement: You are not supposed to prepare a pre-report. But there will be an oral examination, so you are strongly advised to study this note regarding to the pre-study questions
Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template
Application Note Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template Author Jens Baumeister [email protected] Date
Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2
70072-0189-00 TECHNICAL 08/2008 Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2 This document outlines support in ION Enterprise 5.6 Service Pack 2 for PowerLogic CM3000 series/cm4000 series,
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
Electric utilities may vary in their application of end-to-end testing
An Application Case of End-to-End Relay Testing of Communication-Based Protection Schemes Using GPS-Synchronized Secondary Injection Feature by J. Ariza, Megger USA G. Ibarra, CFE, Mexico Electric utilities
GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS
TR TSY 000757 GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS 1. Introduction.... 1.1 Purpose and Scope 1.2 Organization.. 1.3 Reason for Reissue From Technical Advisory
Complete fleet management package for Qualitrol Information Products
+ iq Master Station Configuration, collection and analysis platform Complete fleet management package for Qualitrol Information Products Scalable client-server solution Advanced Record Analysis diagnostics
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
ugrid Testbed. Rein in microgrid complexity. With ease.
ugrid Testbed. Rein in microgrid complexity. With ease. Outsmart the microgrid. ugrid Testbed Ultimate test solution for microgrid control system verification What is a microgrid? Microgrid is a collection
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH
Requirements for Offshore Grid Connections in the Grid of TenneT TSO GmbH Bernecker Straße 70, 95448 Bayreuth Updated: 21 December 2012 1/10 Requirements for Offshore Grid Connections in the Grid of TenneT
Power Quality Standards for Electric Service
Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as
SELECTION OF CURRENT TRANSFORMERS & WIRE SIZING IN SUBSTATIONS. Sethuraman Ganesan ABB Inc. Allentown, PA
SELECTION OF CURRENT TRANSFORMERS & WIRE SIZING IN SUBSTATIONS Sethuraman Ganesan ABB Inc. Allentown, PA ABSTRACT More and more sub-stations are retrofitted with numerical relays, meters and monitoring
EnerVista Viewpoint Monitoring
EnerVista Viewpoint Monitoring Easy to Use Monitoring and Data Recording EnerVista Viewpoint Monitoring is an easy to setup, powerful and simple to use data monitoring and recording software application
Titelgrau belassen! Leere Vorlage
Titelgrau belassen! Leere Vorlage MAVOWATT 20 Energy Platform Energy and Power Analyzer MAVOWATT 20 The new Energy and Power Analyzer 2 Klaus-Peter Richter Product Management 10.3.2010 Page 2 Applications
Paralleling Switchgear
Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more
FREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
Development of an Electrical Power Quality Monitor Based on a PC
Renato Alves, D. Gonçalves, J. G. Pinto, José Batista, João L. Afonso, Development of an Electrical Power Quality Monitor Based on a PC, IECON 2009 - The 35th Annual Conference of the IEEE Industrial Electronics
Network Analyzer for Low-, Medium- and High-Voltage Networks
Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 100 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 Fault recorder
CAN & LIN Development Tool CLDT1004 HS CAN
HW Features : 1 x High Speed CAN Bus up to 1 Mbit/s 4 x digital Signal Output / Trigger Output easy synchronization between CAN Messages and physical HW Outputs SW Features : Can Bus Analyzing Tool Can
Feeder protection. for overhead lines and cables in isolated neutral or compensated networks. Specification
Feeder protection for overhead lines and cables in isolated neutral or compensated networks Specification Feeder protection for overhead lines and cables in isolated neutral or compensated networks Version
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
LogicLab s.r.l Via della valle 67 20048 Carate Brianza (MI) Tel. +39 0362 805287 Fax. +39 0362 1914102 www.logiclab.it
Test system DV1512A2NCI Single Current Generator Maximum current 15 Arms in continuity and 30 Arms per 1 s Single Voltage generator 150 Vrms Programmable phase between Current and Voltage Programmable
Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions
Secure your electrical network The Safety Solution for Healthcare Institutions Fast Secure : the solution for fault isolation and electrical network restoration in less than 500 ms 03 A Real Time System
Electrical Network Management System
Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement
Wide Area Monitoring Current Continental Europe TSOs Applications Overview
Wide Area Monitoring Current Continental Europe TSOs Applications Overview Version 5 System Protection & Dynamics Working Group 20th September 2015 1. Content 1. Content... 2 2. Introduction... 3 3. Main
Numerical Differential Protection
Numerical Differential Protection Principles and Applications Publicis Corporate Publishing 1 Introduction 8 1.1 Protection Principle 8 1.2 Numerical Differential Protection 9 2 Deflnitions 10 3 Mode of
Power Monitoring for Modern Data Centers
Power Monitoring for Modern Data Centers December 2010/AT304 by Reza Tajali, P.E. Square D Power Systems Engineering Make the most of your energy SM Revision #1 12/10 By their nature, mission critical
EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID
Tension (kv) Impedance (Ohms) EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID frequency (Hz) Simon DESCHANVRES Yannick VERNAY RTE, CNER, Substations Department t (ms) EMTP-RV Users Group
Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
Eaton s Electrical Services & Systems. Technical Training Safety Training
Eaton s Electrical Services & Systems Technical Training Safety Training 2 EATON CORPORATION Eaton s Electrical Services & Systems Technical Training Safety Training Eaton conducts technical training and
VOLTAGE REGULATOR AND PARALLEL OPERATION
VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB
This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB Relion. Thinking beyond the box. Designed to seamlessly consolidate functions, Relion relays are smarter,
Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring
Siemens Integrated Substation Condition Monitoring System Circuit Breaker Monitoring System Description Introduction The Circuit Breaker Monitor [CBM] is only one example of the way that the Substation
Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)
Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System) Aye Min Zaw 1, Hla Myo Tun 2 Department of Electronic Engineering, Mandalay Technological
EnerVista Viewpoint Monitoring
EnerVista Viewpoint Monitoring Easy to Use Monitoring and Data Recording EnerVista Viewpoint Monitoring is an easy to setup, powerful and simple to use data monitoring and recording software application
INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012
INTRODUCTION TO SYSTEM PROTECTION Hands-On Relay School 2012 CONGRATULATIONS On choosing the field of system protection. It is an exciting, challenging profession. System protection has changed considerably
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
21 st Century Facilities
Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer
Managing Relion IEDs Protection and control IED manager PCM600
Managing Relion IEDs Protection and control IED manager PCM600 Efficient management of Relion protection and control IEDs The protection and control IED manager PCM600 tool provides versatile functionalities
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System
General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System Direction Planification des actifs et expertise de transport February 2011 TABLE OF CONTENTS 1. CONDUCTING
ECE 586b Course Project Report. Auto-Reclosing
ECE 586b Course Project Report Auto-Reclosing Srichand Injeti May 5, 2008 Department Of Electrical and computer Engineering University Of Western Ontario, London Ontario Table of contents 1. Introduction...1
Power Quality & Custom Power
Day-3 Power Quality & Custom Power Arindam Ghosh Dept. of Electrical Engineering Indian Institute of Technology Kanpur,, India E-mail: aghosh@iitk iitk.ac.in Power Quality (PQ) The term electric power
100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd
100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center Introduction Roger Hedding Steven Schoenherr, P.E. ABB Inc. Minnesota Power 598 N. Buth Rd 3215 Arrowhead Rd Dousman,
Power Electronics Testings
Power Electronics Testings PV Inverter Test Solution www.chromaate.com Turnkey Test & Automation Solution Provider w w w.chromaate.com A PV system is an energy system which directly converts energy from
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
StruxureWare Power Monitoring 7.0.1
WHAT'S NEW 7EN12-0262-01 08/2012 StruxureWare Power Monitoring 7.0.1 StruxureWare Power Monitoring 7.0.1 is the recommended service pack for version 7.0. The StruxureWare Power Monitoring system provides
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
Transmission Protection Overview
Transmission Protection Overview 2012 Hands-On Relay School Brian Smyth Schweitzer Engineering Laboratories Pullman, WA Transmission Line Protection Objective General knowledge and familiarity with transmission
Engineering and service software For KNX and LPB plants
5 649 Engineering and service software For KNX and LPB plants As of V9.00 ACS790 The engineering and service software ACS790 is for KNX and LPB plants equipped with the appropriate bus devices. The software
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Advanced Protection of Distribution Networks with Distributed Generators
Date:- 8 10 March 2011 Venue: University of Manchester EES-UETP Course title Advanced Protection of Distribution Networks with Distributed Generators Peter Crossley Director of the Joule Centre School
PLA 44. Power quality analyzer. User and service manual. BMR trading
PLA 44 Power quality analyzer User and service manual version 1.2 BMR Lipovka 17 516 01 Rychnov n. Kn. 1 Tel: +420 774 415 703 Fax: +420 494 533 602 Content 1. Front panel...3 5.6.1. List of events...8
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems
Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems by Reza Tajali, P.E. Square D Company, Power Systems Engineering Group 295 Tech Park Drive LaVergne, Tennessee 37086
Generator Differential Relay Electrical Apparatus
Generator Differential Relay Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor
EnerVista TM Viewpoint Monitoring v7.10
EnerVista TM Viewpoint Monitoring v7.10 Guideform Specifications July 7, 2014 Page 1 of 14 1 - Product Overview 1.1 Viewpoint Monitoring Scope EnerVista Viewpoint Monitoring is an easy to setup, powerful
ECONseries Low Cost USB DAQ
ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog
New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems
International Conference on Computer and Communication Engineering (ICCCE 2010), 11-13 May 2010, Kuala Lumpur, Malaysia New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
Synchronization. www.andritz.com/neptun
Synchronization www.andritz.com/neptun 02 NEPTUN Synchronization Synchronization 6 x 140 MVA, Birecik, Turkey Synchronizing with success Paralleling of generators to power or one power to ather is a particularly
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Top 10 Benefits of the Paladin DesignBase Power Systems Design and Analysis Platform Jim Neumann, Vice President of Marketing, Power Analytics Corp.
Top 10 Benefits of the Paladin DesignBase Power Systems Design and Analysis Platform Jim Neumann, Vice President of Marketing, Power Analytics Corp. 1. Deployable Design Model: Paladin DesignBase is the
Power Log PC Application Software
Power Log PC Application Software Users Manual May 2007 Rev. 1, 5/08 2007-2008 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks
Kevin Kochirka, ABB Turbine Automation, June 29, 2016. Flexible turbine control retrofits Webinar
Kevin Kochirka, ABB Turbine Automation, June 29, 2016 Flexible turbine control retrofits Webinar Welcome Speaker introduction Kevin Kochirka Sr. Applications Engineer with ABB Inc. [email protected]
Measurement of Power in single and 3-Phase Circuits. by : N.K.Bhati
Measurement of Power in single and 3-Phase Circuits by : N.K.Bhati A specifically designed programme for Da Afghanistan Breshna Sherkat (DABS) Afghanistan 1 Areas Covered Under this Module 1. Power in
Energy Storage System Performance Testing
Energy Storage System Performance Testing Peter Blume President Bloomy Windsor, CT Abstract This paper describes the energy storage system data acquisition and control (ESS DAC) system used for testing
Typical Data Requirements Data Required for Power System Evaluation
Summary 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com [email protected] Harmonic Filter & Power Capacitor Bank Application Studies This document describes NEPSI
How To Use An Hm804X Series Of Power Supplies
value-instruments.com Power Supply All-Rounder for Lab and Test Field data sheet parameters, as well as an impressive variety of effortless features. Despite this large array of features, the instruments
Circulating Current Relay. Type IRXm
Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
Table of Contents. 1. Product Overview... 3. 2. Proposed Solution... 3. 3. System Architecture... 4. 4. Key Modules & Features...
Features. Table of Contents 1. Product Overview... 3 2. Proposed Solution... 3 3. System Architecture... 4 4. Key Modules & Features... 5 5. Product Hardware Device and Software (SaaS) Costing... 10 6.
Engineering innovation
Eaton's Electrical Engineering Services & Systems Solutions Focus Seamless Solutions for Reliable, Efficient and Safe Power Systems Engineering innovation Progressive solutions for today s power systems
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Synchronized real time data: a new foundation for the Electric Power Grid.
Synchronized real time data: a new foundation for the Electric Power Grid. Pat Kennedy and Chuck Wells Conjecture: Synchronized GPS based data time stamping, high data sampling rates, phasor measurements
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.
Standarddescription of TYPE CCR 951 List of contents: A. General Description B. General Data's and Functions C. CCR Working Principle D. Specifications Page 1 of 9 pages A. General Description. Induperm
Part 1 System Modeling & Studies for Existing Systems
Part 1 System Modeling & Studies for Existing Systems Operation Technology, Inc. Copyright 2009 Result of rapid release of energy due to an arcing fault between two conductors. Bus voltages > 208V Temperatures
INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2
INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2 By: R.C. Zowarka T.J. Hotz J.R. Uglum H.E. Jordan 13th Electromagnetic Launch Technology Symposium, Potsdam (Berlin), Germany,
Transfer Equipment Controls
Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment
Event and Fault records in SIPROTEC COMPACT and SIPROTEC 4 relays
Event and Fault records in SIPROTEC COMPACT and SIPROTEC 4 relays This document describes the important Event, Trip and Oscillographic (Waveform) records available in SIPROTEC COMPACT and SIPROTEC 4 devices.
How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
Logging of RF Power Measurements
Logging of RF Power Measurements By Orwill Hawkins Logging of measurement data is critical for effective trend, drift and Exploring the use of RF event analysis of various processes. For RF power measurements,
Low Voltage Products
Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient