MS Series Multi-Stage Electronic Temperature Controls
|
|
|
- Lambert Atkinson
- 9 years ago
- Views:
Transcription
1 Master Catalog 125 Controls Section A Product Bulletin Issue Date 1199 MS Series Multi-Stage Electronic Controls The MS Series Controls are versatile, microprocessor-based, multifunction, programmable temperature controls. They are designed for single and multiple stage temperature control applications. Depending on the model selected, the MS Series Controls can operate in the following modes: Direct mode Reverse mode Deadband mode Independent Setpoint mode The MS Series Controls have large, easy-to-read, red Light-Emitting Diode (LED) displays. These compact controls are available in Panel Mount and DIN Rail Mount models. MS Series Controls use the A99B temperature sensors, which allow remote mounting of the display unit. Figure 1: MS4 Panel Mount and DIN Rail Multi-Stage Electronic Controls Features and Benefits Programmable Functions Alarm Management Functions Easily Readable LED Display Programming Button Lockout Accurate Sensors for Self-Test Procedure Allows adjustment of control settings to meet application needs Provides visible alarm codes on the display Displays temperature and functions quickly and clearly Allows user to disable programming buttons and deter accidental or unauthorized changes Provides accurate control performance with up to 300 feet of wiring (an adjustable offset is provided for longer wiring) Checks control operation by cycling all outputs and testing all LEDs 1999 Johnson Controls, Inc. 1 Code No. LIT
2 Overview IMPORTANT: All MS Series Controls are designed for use only as operating controls. Where an operating control failure would result in personal injury or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) or systems (alarm, supervisory systems) that protect against, or warn of, control failure. Refer to a specific model s installation bulletin for the necessary information on installation, use, and servicing. Table 1: Selected Applications MS1 MS2 MS4 Application!!!!!!!!!!!! Cooling tower pump and/or fan control Rooftop heating or cooling units Boiler or pump control Space temperature control!! Compressor or chiller staging Mode Selection Mode Selection allows selection of one of several modes, depending on the model: Direct mode for cooling applications Reverse mode for heating applications Deadband mode for applications requiring cooling and heating with a common setpoint and a deadband Independent Setpoint mode for applications requiring cooling and heating with an independent setpoint for each Stage Control Functions Adjustable Setpoint Stops restrict setpoint adjustment to avoid extreme settings. The setpoint cannot be changed to a value outside of these stops. Soft Start controls the rate at which temperature approaches the setpoint on power up, both initially and when the binary input is configured as a remote shutoff. Anti-short Cycle Delay avoids situations where the equipment starts, stops, and restarts in a short period of time. This feature determines the minimum time between two subsequent On cycles of the equipment. Binary Input Functions The MS2 and MS4 controls are equipped with a binary input that can perform one of the following functions: Shutoff and Alarm Signaling: When the binary input is open for a time longer than the binary input time delay, all outputs are shut off and an alarm message is displayed. Restart does not use the soft start feature. Setback: When the binary input is open, the setpoints are shifted by a preset value in order to save energy. Remote Shutoff: When the binary input is open for a time longer than the binary input time delay, all outputs are shut off and an alarm message is displayed. Restart uses the soft start feature. 2 A MS Series Multi-Stage Electronic Controls Product Bulletin
3 Dual Sensor Reset This feature resets the Setpoint based on the difference between temperature reading from the Auxiliary Sensor (ATS) and the setpoint. This feature is available only on the MS4 Series and can only be used when the ATS is connected. Alarm Management Functions High and Low Alarms have setpoints relative to the main setpoint. If the temperature reaches or exceeds the alarm values, the display flashes a specific alarm message. On the MS1, an alarm output circuit is energized. The MS2 and MS4 controls have no alarm output. Alarms are disabled for 20 minutes after startup in addition to the alarm time delay. Alarm Delay is used to avoid short-duration events triggering the alarm. Alarm Differential can be set to keep the alarm from cycling rapidly on and off. Sensor Failure is indicated by an alarm message on the display. Alarm codes are displayed by the LEDs and are used to help troubleshoot errors. Alarm codes exist for these conditions: process sensor failure high temperature alarm low temperature alarm program failure binary input codes Self-Test Procedure The self-test procedure allows the user to verify that the LEDs and outputs of an MS control are operating correctly before the control is put into service. Additional Features Programming Button Lockout allows the programming buttons to be deactivated, which deters accidental or unauthorized modifications to the settings. Sensor Offset allows programming an offset of the measured temperature for use with sensor leads longer than 300 ft. Display Updating provides an adjustable refresh rate to avoid displaying short duration fluctuations. Units of Measurement for temperature measurement can use either Fahrenheit or Celsius temperature scales. Dimensions 1 1/8 (28) 2 11/16 (68) 2 5/16 (58) 1 3/8 (35) 2 3/4 (70) 3 (75) Figure 2: Panel Mount Control and A99 Sensor, in. (mm) 2 3/4 (70) (45) (118) 1/4 (6) 2 (50) 2 1/8 (52.5) 78 3/4 (2000) Figure 3: DIN Rail Mount Control, in. (mm) A MS Series Multi-Stage Electronic Controls Product Bulletin 3
4 Display The display has two 7-segment LEDs and a minus (-) indication to display temperatures from -40 to 99 F (-40 to 70 C), with 1F (C ) resolution. Three individual stage status LEDs display the relay status. LED 1 indicates Relay Output 1 is energized. LED 2 indicates Relay Output 2 is energized. LED 3 indicates Relay Output 3 is energized. The MS1 has one stage status LED. The MS2 has two stage status LEDs. The MS4 has three stage status LEDs. Enter Button Stage Status LEDs Up Button Down Button Figure 4: Panel Mount Front Panel and Display Stage Status LEDs Up Button Modes of Operation The MS1 Series Control performs temperature and alarm management for single-stage applications. It operates in either Direct or Reverse modes. The MS2 Series Control performs temperature management for 2-stage applications. In addition to the MS1 modes, it has Deadband and Independent Setpoint modes for applications that require both cooling and heating. The MS4 Series Control performs temperature management for 4-stage applications. It has the same mode selection as the MS2. It can automatically adjust the setpoint to save energy, based on readings from the auxiliary temperature sensor and the function settings. Table 2: Modes of Operation MS1 MS2 MS4 Modes of Operation!!! Direct (Cooling)!!! Reverse (Heating)!! Deadband (Cooling and Heating)!! Independent Setpoint (Cooling and Heating) The illustrations on the following pages show the modes that each MS Series Control is capable of using. Down Button Figure 5: DIN Rail Mount Front Panel and Display The MS1 has one stage status LED. The MS2 has two stage status LEDs. The MS4 has three stage status LEDs. 4 A MS Series Multi-Stage Electronic Controls Product Bulletin
5 Direct Mode (Cooling) Delay On Delay On Stage 4 Differential 4 Delay Stage 3 Differential 3 Off On Stage 2 Differential 2 Off Setpoint 4 (Offset from Setpoint) On Off Setpoint 3 (Offset from Setpoint) Stage 1 Differential Setpoint 2 (Offset from Setpoint) Off Setpoint Figure 6: Direct Mode Direct mode is used for cooling applications. The MS1 has one stage. The MS2 has two stages. The MS4 has four stages. Where desirable, stages may overlap or have space between them. Setpoint is the desired temperature. Differential is the operational range of Stage 1. Setpoint 2 is the offset from setpoint that activates Stage 2. Differential 2 is the operational range of Stage 2. Setpoint 3 is the offset from setpoint that activates Stage 3. Differential 3 is the operational range of Stage 3. Setpoint 4 is the offset from setpoint that activates Stage 4. Delay is the minimum amount of time between two successive stages when multiple stages are called for in rapid sequence. A MS Series Multi-Stage Electronic Controls Product Bulletin 5
6 Reverse Mode (Heating) Off Setpoint On Stage 1 Differential Off Stage 2 Setpoint 2 (Offset from Setpoint) Differential 2 Setpoint 3 (Offset from Setpoint) On Off Setpoint 4 (Offset from Setpoint) Stage 3 Differential 3 Delay On Off Stage 4 Differential 4 Delay On Delay Figure 7: Reverse Mode Reverse mode is used for heating applications. The MS1 has one stage. The MS2 has two stages. The MS4 has four stages. Where desirable, stages may overlap or have space between them. Setpoint is the desired temperature. Differential is the operational range of Stage 1. Setpoint 2 is the offset from setpoint that activates Stage 2. Differential 2 is the operational range of Stage 2. Setpoint 3 is the offset from setpoint that activates Stage 3. Differential 3 is the operational range of Stage 3. Setpoint 4 is the offset from setpoint that activates Stage 4. Differential 4 is the operational range of Stage 4. Delay is the minimum amount of time between two successive stages when multiple stages are called for in rapid sequence. 6 A MS Series Multi-Stage Electronic Controls Product Bulletin
7 Deadband Mode Delay Cooling Stage 4 Differential 4 Stage 2 Differential 2 Setpoint 4 (Offset from Stage 2) Setpoint Setpoint + (1/2 Setpoint 2) Setpoint - (1/2 Setpoint 2) Stage 1 Differential Setpoint 3 (Offset from Stage 1) Stage 3 Differential 3 Heating Delay Figure 8: Deadband Mode Deadband mode is used for applications requiring cooling and heating. The MS2 has two stages. The MS4 has four stages. Where desirable, stages may overlap or have space between them. Setpoint is the desired temperature. Differential is the operational range of Stage 1. Setpoint 2 is width of the deadband, which is centered on setpoint. Differential 2 is the operational range of Stage 2. Setpoint 3 is the offset from the low end of the deadband that activates Stage 3. Differential 3 is the operational range of Stage 3. Setpoint 4 is the offset from the high end of the deadband that activates Stage 4. Differential 4 is the operational range of Stage 4. Delay is the minimum amount of time between two successive stages when multiple stages are called for in rapid sequence. A MS Series Multi-Stage Electronic Controls Product Bulletin 7
8 Independent Setpoint Mode Delay Cooling Stage 4 Differential 4 Stage 2 Differential 2 Setpoint 4 Setpoint Stage 1 Differential Setpoint 3 Stage 3 Differential 3 Heating Delay Figure 9: Independent Setpoint Mode Independent Setpoint mode is used for applications requiring cooling and heating. The MS2 has two stages. The MS4 has four stages. Where desirable, stages may overlap or have space between them. Setpoint is the desired heating temperature. It is the basis for the reverse stages. Differential is the operational range of Stage 1. Setpoint 2 the desired cooling temperature programmed by the user. It is the basis for the direct stages. Differential 2 is the operational range of Stage 2. Setpoint 3 is the offset from Setpoint that activates Stage 3. Differential 3 is the operational range of Stage 3. Setpoint 4 is the offset from Setpoint 2 that activates Stage 4. Differential 4 is the operational range of Stage 4. Delay is the minimum amount of time between two successive stages when multiple stages are called for in rapid sequence. 8 A MS Series Multi-Stage Electronic Controls Product Bulletin
9 Function Definitions The MS Series controls include a variety of temperature and alarm management functions, which are listed below. Not all of these functions are available on every model. Refer to Table 3 for functions and setting ranges for specific models. Management Setpoint is the primary control point programmed by the user. Setpoint 2, Setpoint 3, Setpoint 4 depend on the mode used. For information on function in each mode, see Modes of Operation. Differentials (or hysteresis) establishes the difference between the value at which the output is switched Off and the value at which the output is switched On. For further information, see Modes of Operation. Example: In Direct (cooling) mode, with the setpoint at 40 F, and the differential at 4F, the compressor is switched On when the temperature goes above 44 F, and is turned Off when the temperature decreases to below 40 F. High and Low Setpoint Stops are temperature settings ( F or C) that define how high and low the primary setpoint may be adjusted. Setpoint stops deter unauthorized or accidental overadjustment of setpoint. Anti-short Cycle r, Direct establishes the minimum time in minutes between two subsequent On cycles of Direct (cooling) stages. Anti-short Cycle r, Reverse establishes the minimum time in minutes between two subsequent On cycles of reverse (heating) stages. Anti-short Cycle r Load Demand Output Status Figure 10: Anti-short Cycle r Delay is the minimum amount of time between two successive stages when multiple stages are called for in rapid sequence. Soft Start controls the rate at which the process temperature is allowed to approach the setpoint on power up, both initially and when the binary input is configured as remote shutoff. The setting is minutes/temperature units, such as minutes/f. Example: Process temperature = 20 Setpoint = 30 Soft start = 2 minutes Rate of Increase = Soft start x (setpoint sensor reading) Process setpoint increases by 1 every two minutes, until the setpoint temperature is reached. To go from 20 to 30 takes 10 minutes. Sensor Offset allows the user to compensate for temperature differences between actual and displayed temperature, such as those experienced when using long sensor leads or when the location of the sensor results in inaccurate readings. Units allows the user to select either the Fahrenheit or Celsius temperature scale. Display Refresh Rate establishes the time delay (seconds) between updates of the temperature display. A MS Series Multi-Stage Electronic Controls Product Bulletin 9
10 Heating Reset and Cooling Reset are used in Deadband mode. The reset is an automatic shift of the setpoint, based on the temperature at the Auxiliary Sensor (ATS). Non-compensated Band establishes the temperature range (F or C ) over which reset does not take place. Alarm Management High Alarm sets the temperature ( F or C) relative to setpoint at which the control goes into a high temperature alarm condition. Example: If setpoint is 40 F and high temperature alarm is 15F, the alarm message will be displayed at or above 55 F. Low Alarm sets the temperature ( F or C) relative to setpoint at which the control goes into a low temperature alarm condition. Example: If setpoint is 40 F and low temperature alarm is -10F, an alarm message will be displayed at or below 30 F. Alarm Differential establishes the difference (F or C ) between the temperature at which the alarm is activated and the temperature at which the alarm is deactivated. On the MS1, alarm activation triggers an external alarm and displays an alarm message. On the MS2 and MS4, an alarm message is displayed. Example (cooling): Setpoint = 40 F High Alarm = 15F Alarm Differential = 2F When the room temperature exceeds = 55 F for a time greater than the alarm time delay setting, the alarm message is displayed; however, it will reset after the temperature drops below =53 F. Alarm Delay establishes the time delay (minutes) between reaching an alarm condition (high or low temperature) and activating the alarm. This function reduces nuisance alarms caused by transient changes that temporarily exceed alarm setpoint temperatures. Conditions that would cause a temperature alarm are disregarded by the unit during the first 20 minutes after power up. Binary Input Binary Input Function allows the user to select how the binary input will activate the stage control contacts. The user can select to disengage this function or set one of three actions: Shutoff and Alarm Signaling - If the binary input contact is open for a time longer than that set through the binary input time delay, the stage control contacts are switched Off, and an alarm message (A1) is displayed. On the MS1, the alarm is also activated. Setback - If the binary input contact is open for a time longer than that set through the binary input time delay, the setpoints are shifted by setback. Reverse setpoints (heating) decrease. Direct setpoints (cooling) increase. Remote Shutoff of the outputs. - If the binary input contact is open for a time longer than that set through the binary input time delay, the stage control contacts are switched Off. If a set of stage control contacts are used to control an external alarm, this function should be disabled. Binary Input Delay establishes the time delay (minutes) between binary signal reaching the control and control s response to the binary signal. Setback determines the value of the setpoint shift when the binary input is open and the binary input function is set at setback. 10 A MS Series Multi-Stage Electronic Controls Product Bulletin
11 Reset Heating reset, cooling reset, and Non-compensated Band (NCB) are used only with the MS4. Heating reset only affects the heating setpoint, and cooling reset only affects the cooling setpoint. These functions appear only when the Auxiliary Sensor (ATS) is connected. Heating Reset When the ATS reading is lower than the setpoint, and the difference exceeds the deadband, temperature reset will take place. The setpoint will be lowered. Degrees of reset are equal to: [ATS (setpoint NCB)] / heating reset Cooling Reset When the Auxiliary Sensor (ATS) reading is higher than the setpoint, and the difference exceeds the deadband, temperature reset will take place. The setpoint will be raised. Degrees of reset are equal to: [ATS (setpoint + NCB)] / cooling reset Non-compensated Band (NCB) The temperature range over which reset does not take place. Reset Examples Heating Reset Example: Setpoint = 70 Auxiliary Sensor (ATS) = 42 NCB = 20 Heating Reset = 2 Step 1 ATS (setpoint NCB) = differential 42 (70 20) = -8 Step 2 differential/heating reset = reset -8/2 = -4 Step 3 setpoint + reset 70 + (-4) = 66 Setpoint is reset to 66 to save energy. Cooling Reset Example: Setpoint = 70 Auxiliary Sensor (ATS) = 92 NCB = 10 Cooling Reset = 2 Step 1 ATS (setpoint + NCB) = differential 92 ( ) = 12 Step 2 differential/cooling reset = reset 12/2 = 6 Step 3 setpoint + reset = 76 Setpoint is reset to 76 to save energy. Heating Reset Only Affects Heating Stages Cooling Reset Only Affects Cooling Stages 1 Heating Reset Setpoint Process Setpoint 1 Cooling Reset Auxiliary Sensor (ATS) 42 Deadband NCB = Deadband NCB = Auxiliary Sensor (ATS) Figure 11: Reset Examples A MS Series Multi-Stage Electronic Controls Product Bulletin 11
12 Table 3: Functions and Settings MS1 MS2 MS4 Setting Setting Range!!! D = Direct (Cooling)!!! R = Reverse (Heating) Mode Selection!! B = Deadband (Direct and Reverse)!! I = Independent Setpoint (Direct and Reverse)!!! Setpoint -40 to 99 F (-40 to 70 C)!!! Differential 1 F /1 to 9 C!! Setpoint 2 D, R modes 1 to 40F (1 to 40C ) B mode I mode!! Differential 2 1 to 9F (1 to 9C )! Setpoint 3 1 to 40F (1 to 40C )! Differential 3 1 to 9F (1 to 9C )! Setpoint 4 1 to 40F (1 to 40C )! Differential 4 1 to 9F (1 to 9C )!!! Low Setpoint Stop -40 to High Setpoint Stop 2 to 40F (2 to 40C ) Low to High Setpoint Stop!!! High Setpoint Stop Low Setpoint Stop to 99 F (70 C)!! Delay 3 to 90 seconds!!! Anti-short Cycle r, Direct 0 to 9 minutes!!! Anti-short Cycle r, Reverse 0 to 9 minutes!!! Soft Start 0 to 99 minutes/1f (1C )! Heating Reset 0 to 6F (0 to 6C )! Cooling Reset 0 to 6F (0 to 6C )! Non-compensated Band 0 to 20F (0 to 20C )!!! Sensor Offset -20 to +20F (-20 to +20C )!!! Units Used 0 = C 1 = F!!! Display Refresh Rate 1 to 99 seconds!!! High Alarm 0 to 50F (0 to 50C ) above Setpoint!!! Low Alarm -50 to 0F (-50 to 0C ) below Setpoint!!! Alarm Differential 1 to 9F (1 to 9C )!!! Alarm Delay 0 to 99 minutes!! Binary Input Function 0 = No binary input 1 = Shutoff and alarm signaling 2 = Setback 3 = Remote shutoff!! Setback 0 to 20F (0 to 20C )!! Binary input Delay 0 to 99 minutes 12 A MS Series Multi-Stage Electronic Controls Product Bulletin
13 MS1 One Stage Electronic Control The MS1 control is designed for 1-stage temperature and alarm control applications. This model uses the A99B Series temperature sensors. Process Sensor S1 SC Sensor Common Terminal Not Used Alarm A+ A- + - Modes of Operation Direct (Cooling) Reverse (Heating) Management Settings Setpoint V1 V2 C1 Power Supply ➀ Stage ➀ Internal to Control Refer to Rating Table for more information. Differential (Hysteresis) Low Setpoint Stop High Setpoint Stop Anti-short Cycle r Figure 12: MS1 DIN Rail Mount Wiring Soft Start Table 4: Rating Table Rating Category 120 VAC 240 VAC 24 VDC Sensor Offset Units Used Display Refresh Rate Horsepower 1/4 1/2 - Full Load Amperes Locked Rotor Amperes Inductive (non-motor) Amperes Pilot Duty VA Alarm circuit is 40 VDC, 100 ma maximum. Alarm requires separate power source. Power supply is 24 VAC. Alarm Management Settings High Alarm Low Alarm Alarm Differential Alarm Delay Table 5: Ordering Information Product Code Number MS1DR24T-11C Description MS1 DIN Rail Mount Control; A99BB-200C sensor included; shipping weight 0.75 lb (340 g) A MS Series Multi-Stage Electronic Controls Product Bulletin 13
14 MS2 Two Stage Electronic Control The MS2 control is designed for 2-stage temperature control applications. These models use the A99B Series temperature sensors. Sensor Common Process Sensor V1 S1 V2 SC Binary Input D C1 CD ➀ Binary Common Internal to Control Stage ➁ C2 Terminal Not Used Power Stage ➀ Supply Refer to Rating Table for more information. Figure 13: MS2 DIN Rail Mount Wiring Refer to Rating Table for more information. Internal to Control C1 ➀ Stage ➀ C2 ➁ Stage ➁ V1 V2 D SC ➁ Terminal Not Used Binary Power Input Process Supply Sensor Binary and Sensor Common Figure 14: MS2 Panel Mount Wiring Table 6: Rating Table Rating Category 120 VAC 240 VAC 24 VDC Horsepower 1/4 1/2 - Full Load Amperes Locked Rotor Amperes Inductive (non-motor) Amperes Pilot Duty VA Power supply is 24 VAC. Modes of Operation Direct (Cooling) Reverse (Heating) Deadband (Cooling and Heating) Independent Setpoint (Cooling and Heating) Management Settings Multiple Setpoints Multiple Differentials (Hysteresis) Low Setpoint Stop High Setpoint Stop Delay Anti-short Cycle rs Soft Start Sensor Offset Units Used Display Refresh Rate Alarm Management Settings High Alarm Low Alarm Alarm Differential Alarm Delay Binary Input Management Settings Binary Input Function Selection Binary Input Delay Setback Table 7: Ordering Information Product Code Number MS2DR24T-11C MS2PM24T-11C Description MS2 DIN Rail Mount Control; A99BB-200C sensor included; shipping weight 0.79 lb (360 g) MS2 Panel Mount Control; A99BB-200C sensor included; shipping weight 0.53 lb (240 g) 14 A MS Series Multi-Stage Electronic Controls Product Bulletin
15 MS4 Four Stage Electronic Control The MS4 control is designed for 4-stage temperature control applications. These controls use the Johnson Controls/PENN A99B temperature sensor. Refer to Rating Table for more information. C ➀ ➁ ➂ ➃ Stage Stage ➀ ➂ Stage ➁ Internal to Control V1 V2 Power Supply Binary Common Input Auxiliary Sensor D S2 SC S1 Process Sensor Binary / Sensor Common Figure 15: MS4 Panel Mount Wiring Binary Input Sensor Common Binary and Sensor Common Process Sensor SC D CD S2 Internal to Control V1 V2 C1 ➀ Stage ➀ Power Supply Terminal Not Used Auxiliary Sensor C4 Stage ➃ Stage ➁ C2 C3 ➁ ➂ Stage ➂ See Rating Table for more information. Figure 16: MS4 DIN Rail Mount Wiring Table 8: Rating Table Rating Category 120 VAC 240 VAC 24 VDC Horsepower 1/4 1/2 - Full Load Amperes Locked Rotor Amperes Inductive (non-motor) Amperes Pilot Duty VA Power supply is 24 VAC. Relay outputs must not exceed 20 amperes total connected load. Modes of Operation Direct (Cooling) Reverse (Heating) Deadband (Cooling and Heating) Independent Setpoint (Cooling and Heating) Management Settings Multiple Setpoints Multiple Differentials (Hysteresis) Low Setpoint Stop High Setpoint Stop Delay Anti-short Cycle rs Soft Start Heating Reset Cooling Reset Non-compensated Band Sensor Offset Units Used Display Refresh Rate Alarm Management Settings High Alarm Low Alarm Alarm Differential Alarm Delay Binary Input Management Settings Binary Input Function Selection Binary Input Delay Setback Table 9: Ordering Information Product Code Number MS4DR24T-11C MS4PM24T-11C Description MS4 DIN Rail Mount Control; includes one A99BB-200C sensor; shipping weight 1.17 lb (530 g) MS4 Panel Mount Control; includes one A99BB-200C sensor; shipping weight 0.90 lb (410 g) A MS Series Multi-Stage Electronic Controls Product Bulletin 15
16 Table 10: Replacement Sensor Ordering Information Product Code Number Operating Range Cable A99BB-200C A99BB-300C A99BB-500C A99BB-600C A99BA-200C -40 to 212 o F (-40 to 100 o C) 6-1/2 ft (2 m) PVC 9-3/4 ft (3 m) PVC 16-3/8 ft (5 m) PVC 19-1/2 ft (6 m) PVC 6-1/2 ft (2 m) Shielded Table 11: Electrical Ratings of Contacts Rating Category 120 VAC 240 VAC 24 VDC Horsepower 1/4 1/2 --- Full Load Amperes Locked Rotor Amperes Inductive (non-motor) Amperes Pilot Duty VA Relay outputs must not exceed 20 amperes total connected load. Open collector transistors on the MS1 alarm circuits have a maximum rating of 40 VDC, 100 ma. Alarm requires separate power source. Specifications Product Power Requirements Accuracy MS Series One-and Multi-Stage Electronic Controls VAC, 50/60 Hz, Class 2 (20-30 VAC) ± 1.8F (± 1C ) Ambient Conditions Operating: +14 to +140 F (-10 to +60 C); 0 to 95 % RH (non-condensing) Storage: -22 to +176 F (-30 to +80 C); 0 to 95 % RH (non-condensing) Agency Listings UL Recognized: File E194024, CCN XAPX2 Canadian UL Recognized: File E194024, CCN XAPX8 FCC Compliant per Class A Digital Device, Part 15 Canadian DOC Compliant per Class A, Radio Interference Regulations Dimensions (H x W x D) Panel Mount: 1.38 x 2.95 x 2.68 in. (35 x 75 x 68 mm) DIN Rail: 4.65 x 2.76 x 2.07 in. (118 x 70 x 52.5 mm) Shipping Weight See ordering information in Tables 5, 7, and 9. The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult Johnson Controls/Penn Refrigeration Application Engineering at (414) Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group FAN E. Michigan Street Master Catalog P.O. Box 423 Printed in U.S.A. Milwaukee, WI A MS Series Multi-Stage Electronic Controls Product Bulletin
System 350 A350E Electronic Cooling Control
FANs 930, 930.5, 125, 121 Product/Technical Bulletin A350E Issue Date 0899 System 350 A350E Electronic Cooling Control The A350E is an on/off, electronic, cooling-only control with Single-Pole, Double-Throw
P70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
A99B Series Temperature Sensors
FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures
Product/Technical Bulletin A419 Issue Date August 13, 2014 A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures The A419 series controls are single-stage,
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
Solid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
System 350 A350R Electronic Temperature Reset Control (with Relay)
FANs 930, 930.5, 125, 121 Product/Technical Bulletin A350R Issue Date 0899 System 350 A350R Electronic Temperature Reset Control (with Relay) The A350R Electronic Temperature Reset Control is designed
P66 Series Electronic Fan Speed Controls
P66 Series Electronic Fan Speed Controls Product Bulletin Code No. LIT-125465 Issued September 30, 2009 Supersedes March 23, 2006 The P66 Series Electronic Fan Speed Controls are refrigerant pressure actuated,
Commercial Refrigeration Temperature and Defrost Controls
Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys
Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.
TEC22x6(H)-4 and TEC22x6H-4+PIR Series LONWORKS Network Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011607 Issued
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control
TEC26x6(H)-4 and TEC26x6H-4+PIR Series BACnet MS/TP Networked Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011587
*.ppt 11/2/2009 12:48 PM 1
Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers
T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers Product Bulletin T600HCx-4, T600HPx-4, T600MSx-4, T600MEP-4, T600HCx-4+PIR, T600HPx-4+PIR, T600MSx-4+PIR, T600MEP-4+PIR The T600xxN-4 and T600xxN-4+PIR
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
G670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
DCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
Configuring Alarms & Relays in the Enhanced Transformer Advantage
Configuring s & Relays in the Enhanced Transformer Advantage The Transformer Advantage product family offers a variety of relay options. Some choices are made when the Advantage is specified and ordered.
Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives
DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)
1 For All Non-Programmable Digital Thermostat
OWNER'S MANUAL P/N P474-0100 1 For All Non-Programmable Digital Thermostat TOTALINE 68 Dual Setpoint Very easy to program Thermoglow Backlight No batteries required Auto-Changeover Locking Keypad Meets
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
Application Engineering
Application Engineering February 2011 Electronic Unit Controller Table of Contents 1. Introduction and Features... 2 1.1 Technical Specifi cations... 3 1.2 Pressure Probe Error Bypass... 3 1.3 Bump Start...
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies
REV. G Cooler is Better! TM Owner s Manual Walk-in Monitoring System 100 Used in UL Listed Door Panel Assemblies American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352)
Controller Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
Short information Parameters are programmed via front-side membrane keypad
Digital remote display for Flow Meter DM /DE Universal meter UZ Indication of the quantity consumed in m³ Features LED-Display 14.2mm red Indicating range -99999... 999999 0... 3 Decimal points programmable
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
Data Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
Operational Overview and Controls Guide
DOCUMENT: ECSEQ2-1 EFFECTIVE: 02/14/07 SUPERSEDES: 02/26/03 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)
Polyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
T-4000 Series Pneumatic Room Thermostats
T-4000 Series Pneumatic Room Thermostats Pneumatic Control Manual 717.1 Room Devices Section Product Bulletin T-4000 Issue Date 1285 Features Adjustable Sensitivities and Set Points Individual Set Points
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description
Technical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
ITC-308 Plug and Play Temperature Controller
ITC-308 Plug and Play Temperature Controller 1. Overview ITC-308 is an easy-to-use, safe and reliable dual relay output temperature controller. It can be used as Over-temperature protection and automatic
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
TEC Series BACnet MS/TP Network Temperature and Humidity Controllers
TEC Series BACnet MS/TP Network Temperature and Humidity Controllers Technical Bulletin Code No. LIT-12011592 Issued March 4, 2013 Supersedes May 13, 2011 Refer to the QuickLIT Web site for the most up-to-date
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
IO-RM3 3-Stage Relay Module
Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED
Generator Differential Relay Electrical Apparatus
Generator Differential Relay Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46
PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46 Display 1. Red measurement display (or the set point for CTD 43 by pressing, indicated by a flashing decimal point). 2. Green display of
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
VARIO PROX CARD READER INSTALLATION MANUAL
VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Variable Air Volume - VAV
Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.