1 Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control Description Application Requirements The is a n-100% Lockout Intermittent Pilot Ignition (IPI) control that replaces the G67AG and G67BG ignition controls. The is used to automatically light a pilot burner and energize the main burner gas valve in response to a call for heat from the system thermostat. When the call for heat is satisfied, the thermostat opens and the de-energizes the pilot and main burner gas valves. Following are the application requirements of the control. The can be used with equipment with a maximum firing rate of 117 kw (400,000 Btu/hr). Any application greater than 117 kw (400,000 Btu/hr) must have written approval in advance from the Heating Products Engineering Department. All applications must use a redundant gas valve system with the main valve seats in series Johnson Controls, Inc. 1 Part , Rev. B Code. LIT

2 Table 1: Specifications Ignition Type Ignition Source High Voltage Cable Length Flame Detection Means Flame Detection Types Minimum Flame Current Flame Failure Response Time Spark Gap Ignition Trial Time Indirect High voltage spark, capacitive discharge 915 mm (36 in.) maximum Flame rectification Remote sensing 0.2 microampere 0.8 second, maximum 2.5 mm (0.1 in.) nominal Infinite Power Requirements Control: 24 VAC, 50/60 Hz, nominal Operation Current: 0.15A nominal + valves Contact Rating Main Valve: 2A continuous, 5A inrush Pilot Valve: 2A continuous, 5A inrush Ambient Operating and -40 to 66 C (-40 to 150 F) Storage Temperature Humidity 95% RH non-condensing Types of Gas Natural (Liquefied Petroleum [LP], manufactured, mixed, or LP gas-air mixture may be used in a well vented or outdoor application.) Agency Listing CSA (AGA/CGA) Certificate Number Specification Standards ANSI Standard Z21.20 CSA C The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Operating Mode Definitions The following definitions describe operating conditions. Trial for Ignition--Period during which the pilot valve and spark are activated attempting to ignite gas at the main burner. The trial-for-ignition period is infinite for the s and ends once the pilot flame is detected or the call for heat ends. Run--The main valve remains energized and the spark is turned off after successful ignition. Flameout--Loss of proven flame. Should a flameout occur, the main valve closes and the spark recurs within 0.8 second. 2 G Intermittent Pilot Ignition Controls Technical Bulletin

3 Sequence of Operation Figure 2 illustrates the sequence of operation for the ignition control. On a call for heat from the system thermostat, the simultaneously opens the pilot valve and supplies a continuous spark to the pilot burner s electrode. When the pilot burner gas ignites, the pilot flame sensor detects the pilot flame and signals the to energize the main gas valve and discontinue the spark. The main gas valve will not be energized until the flame sensor detects the presence of the pilot flame. If the pilot flame goes out (with the thermostat still calling for heat), the will de-energize the main gas valve and provide a continuous spark at the pilot burner s electrode. When the pilot flame is re-ignited and detected by the pilot flame sensor, the main gas valve is energized and the spark is shut off. The de-energizes the pilot gas valve and main burner gas valve when the thermostat stops calling for heat. Start Thermostat Call for Heat Flame Present? Trial for Ignition Pilot Flame Sensed? Energize Main Valve Run Flameout? De-energize Main Valve Thermostat Calling for Heat? De-energize Control Pilot and Main Valves End Figure 2: Sequence of Operation G Intermittent Pilot Ignition Controls Technical Bulletin 3

4 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing Johnson Controls ignition controls. Carefully follow all instructions in this bulletin and all instructions on the appliance. Limit repairs, adjustments, and servicing to the operations listed in this bulletin or on the appliance.! WARNING: Fire or Explosion Hazard. Avoid serious injury by carefully following precautions in this bulletin and all instructions on the appliance. Limit repairs, adjustments, and servicing to the operations listed in this bulletin or on the appliance.! WARNING: Fire or Explosion Hazard. If the control is installed in an area that is exposed to water (dripping, spraying, rain, etc.), it must be protected. If the control has been exposed to water in any way, do not use it.! WARNING: Shock Hazard. Avoid electrical shock and equipment damage. Disconnect electrical power and turn off the gas before wiring the control.! CAUTION: Equipment Damage Hazard. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Mounting Perform the following procedure to install the ignition control. 1. Shut off power to the appliance. 2. Turn off gas at the manual shutoff valve adjacent to the appliance. 3. Label each wire with the correct terminal designation prior to disconnection. 4. Disconnect the power supply (transformer) and the thermostat lead wire at the ignition control. 5. Disconnect the sensing probe lead from Terminal 4 on the ignition control. 6. Disconnect the high voltage cable from the spark transformer. 7. Disconnect the Pilot Valve 1 and Main Valve 3 leads from the ignition control. 8. Disconnect any wires connected to the ground terminals on the ignition control. 4 G Intermittent Pilot Ignition Controls Technical Bulletin

5 9. Remove the screws holding the ignition control assembly in place. 10. Remove the ignition control and discard. 11. Using the same holes as the old ignition, mount the new control on a grounded metal surface with metal screws or bolts through the mounting holes provided on the enclosure. Modifying Existing Ignition Cable All spark ignition controls have a spark transformer connected to a high voltage cable. There are three types of connection for the high voltage cable: Spike, Rajah, and 6.35 mm (1/4 in.) male spade (see Figure 3). The has a Spike transformer. When replacing a control that has a Rajah or male spade connection, the crimp-on connector must be cut off. 1. Slide the rubber boot up the cable. 2. Cut the lead just above the connector (see Figure 4). Make a straight cut perpendicular to the cable. 3. Center the exposed wire on the end of the lead over the spike in the spark transformer and push the wire lead down firmly over the spike (see Figure 5). 4. Ensure the lead is inserted all the way into the spark transformer. Slide the boot back down the cable and over the spark transformer. Spike Connection Rajah Connection 6.35 mm (1/4 in.) Male Spade Figure 3: High Voltage Cable Connectors High Voltage Cable Insulating Boot Crimp-on Connector Cut off connector here. Figure 4: High Voltage Cable with Crimp-On Connector High Voltage Cable Spike must be in contact with the center wires. Figure 5: Spark Transformer Connection G Intermittent Pilot Ignition Controls Technical Bulletin 5

6 Wiring! CAUTION: Equipment Damage Hazard. Connect the high voltage cable to the spark transformer terminal and spark electrode (pilot burner assembly) before applying power to the control. Ensure the ground wire is attached to the pilot burner and control ground terminal strip.! CAUTION: Equipment Damage Hazard. Locate all limit and operating controls in series with the thermostat terminal (THS 2) on the ignition control. Check the voltage rating marked on the control and make sure it is suited to the application. Use a National Electrical Code (NEC) Class 2 transformer to provide 24 VAC under maximum load, including valves. A transformer having excessive primary impedance due to poor coupling will affect the ignition potential. Refer to Figures 6 through 9 for wiring diagrams. All wiring should be in accordance with the NEC and all other local codes and regulations. The high voltage spark transformer cable must not be in continuous contact with a metal surface. Use standoff insulators. Ensure that the flame sensor wire and the high voltage spark transformer cable are separated from one another by a minimum distance of 6.35 mm (1/4 in.) and are not wrapped around any pipe, other wiring, or accessories. 6 G Intermittent Pilot Ignition Controls Technical Bulletin

7 Thermostat Limits in the Thermostat Line Only W R Y MV Jumper PV in 24 VAC Power Supply Pilot Burner Ground Ground Terminals Flame Sensor High Voltage Cable Figure 6: ment Wiring Diagram if the Original Control is a G67AG Thermostat W R Y Limits in the Thermostat Line Only MV PV Jumper 5 24 VAC Power Supply Pilot Burner Ground Ground Terminals Flame Sensor Install the jumper supplied with the replacement control between Terminals 2 and 6. High Voltage Cable Figure 7: ment Wiring Diagram if the Original Control is a G67BG G Intermittent Pilot Ignition Controls Technical Bulletin 7

8 Thermostat High Limits In This Line Only W R Y MV Y79 MV PV Power Supply 24 VAC PV Jumper 5 Brown White Pilot Burner Ground Black Flame Sensor Install the jumper supplied with the replacement control between Terminals 2 and 6. High Voltage Cable Figure 8: Wiring Diagram for with Y79B Thermostat W R Y Y79 THS High Limits In This Line Only MV PV Jumper 5 24 VAC White Power Supply Pilot Burner Ground Red Black Flame Sensor High Voltage Cable Figure 9: Wiring Diagram for with a Y79A 8 G Intermittent Pilot Ignition Controls Technical Bulletin

9 Checkout and Startup Procedure! WARNING: Fire or Explosion Hazard. Avoid personal injury or property damage by making sure the control functions properly and there are no gas leaks. Follow this checkout and startup procedure before leaving the installation.! WARNING: Fire or Explosion Hazard. Do not attempt to check out this system by manually lighting the pilot. This could energize the main valve. Make sure all components are functioning properly by performing the following shutoff test. 1. With the gas and thermostat off, turn on power to the appliance. 2. Turn on the thermostat to the highest setting and verify that the control goes through the operating sequence to a shutoff condition. te: The burner will not light because the gas is off. 3. Turn off the thermostat. 4. Turn on the gas and purge gas lines of all air. 5. Test for gas leaks on all pipe joints and connections upstream of the gas valve with a soap solution. 6. Turn on the thermostat to the highest setting and verify successful ignition and a normal run condition for at least three minutes. If the appliance fails to run, see the Service Checkout Procedures section. 7. Test for leaks on all pipe joints and connections downstream of the gas valve with a soap solution. 8. Turn the thermostat down for at least 30 seconds and then back up again. Verify successful ignition at least three times. 9. Return the thermostat to a normal temperature setting before leaving the installation. G Intermittent Pilot Ignition Controls Technical Bulletin 9

10 Thermostat Heat Anticipator Settings The thermostat anticipator setting is normally equal to the ignition system current draw, plus that of the pilot and main valve. Due to variations in appliance wiring and valves, it is advisable to measure the actual current draw of the heating system at the thermostat location. Measuring this current can be accomplished by opening the thermostat contacts (lowering the set point) and installing an AC ammeter across the terminals, or by using a clamp-on ammeter with a 10-turn multiplier attached to the terminals (see Figure 10). IMPORTANT: Measuring the current with an ammeter will energize the system. Wait until the gas valve and inducer energize before taking a current draw measurement. To Heating System W R AC Ammeter Low Scale Setting To Heating System W R Ten Turns Clamp-on Ammeter (Divide reading by ten.) Figure 10: Measuring the Thermostat Current 10 G Intermittent Pilot Ignition Controls Technical Bulletin

11 Troubleshooting Procedure Preliminary Checks Failure Conditions and Corrective Action If the system does not function properly, determine the cause using the procedures in this section. Before proceeding with troubleshooting the system, check the following: Are all mechanical and electrical connections tight? Is the system wired correctly? Is the gas inlet pressure per the manufacturer s specifications? Is the system powered? Is the thermostat calling for heat? There are three potential system failure conditions: no spark, and system does not work spark is present, but pilot does not light pilot lights, but main valve does not come on Determine the failure condition, then use the respective flowcharts on the following pages to troubleshoot the system. Perform the procedures in the Checkout and Startup Procedure section after any servicing. Repairs and ment! CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Do not attempt field repairs. Use only exact or factory recommended replacement controls. All other accessories, such as flame sensors, electrode assemblies, pilot assemblies, and leads can be obtained through the original equipment manufacturer or a Johnson Controls distributor. G Intermittent Pilot Ignition Controls Technical Bulletin 11

12 Start Visually check. Is Lead 5 connected securely to ground? Connect securely Are thermostat and limit contacts closed? Is 24 VAC present between Terminal 2 and ground? Is 24 VAC present between Terminal 6 and ground? Close contacts Repair Is circuit wiring providing 24 VAC to Terminal 2? Is 24 VAC present between Terminal 1 and ground? Check for proper voltage at transformer primary and secondary te: In some instances a jumper is used between Terminals 2 and 6 to power Terminal 6. Is circuit wiring providing 24 VAC to Terminal 6? Repair Turn off supply voltage cable Is high voltage cable in good condition (not brittle, burnt, or cracked)? Is high voltage cable connected to spark transformer? Is spark gap 0.1 in. and located in pilot gas stream? Correct or replace pilot burner Is spark electrode ceramic cracked? pilot burner Connect securely Turn on supply voltage Turn on supply voltage Operate system several complete cycles End Figure 11: Spark, and System Does t Work 12 G Intermittent Pilot Ignition Controls Technical Bulletin

13 Start Is pilot valve wiring securely connected to Terminal 1 and ground? Connect securely Is 24 VAC present between Terminal 1 and ground?! WARNING: Explosion Hazard. Do not use a match to test for presence of gas. Is inlet gas pressure per manufacturer s specifications? Is gas at pilot? Make sure pilot line is not kinked or obstructed. Check for clean orifice. Correct gas pressure pilot valve Is pilot spark gap 0.1 in. and located in pilot gas stream? Correct or replace pilot Check for drafts. Shield as necessary and check for clean orifice. End Figure 12: Spark is Present, but Pilot Does t Light G Intermittent Pilot Ignition Controls Technical Bulletin 13

14 Start Does spark stay on for more than 30 seconds after the pilot lights? Is 24 VAC between Terminal 3 and ground? Is inlet gas pressure per manufacturer s specifications? Correct gas pressure Make sure sensor cable and high voltage cable are separated and not wrapped around any pipe or accessories. Is main valve wiring securely connected to Terminal 3 and ground? Connect securely Is sensor cable securely connected to Terminal 4 and flame sensor? Connect securely main valve Is sensor ceramic cracked? Is cable grounded out? Is sensor or sensor connector shorted out to metal surface? Correct sensor Correct Is there continuity and good insulation in the sensor cable? cable Connect DC microammeter between sensor cable terminal and Terminal 4. Observe correct polarity. See Figure 20. Disconnect sensor cable from Terminal 4 Disconnect main valve lead from Terminal 3 Is DC current 0.2 microamperes or greater with pilot only operation? Check for: - proper gas pressure - clean pilot assembly - tight mechanical and electrical connections If there is not improvement, change the flame sensor length or the orifice size and perform any necessary turn down tests. End Figure 13: Pilot Lights, but Main Burner Does t Come On 14 G Intermittent Pilot Ignition Controls Technical Bulletin

15 Start Is system wiring per manufacturer s instructions? Open thermostat contacts for 30 seconds Correct wiring Close thermostat contacts and wait 30% of the Y79 lockout time Is a spark present? System was in lockout Determine reason for lockout. Conduct microamperage test as outlined in Figure 16, starting at A. Is 24 VAC present between Terminal 2 and ground? Is 24 VAC present between Terminal 1 and ground? Turn off supply voltage Connect securely Check the high voltage cable. Is it securely connected to the spark transformer? Is 24 VAC present on secondary of transformer? Turn supply voltage on the transformer if proper voltage is present on primary of transformer. Is high limit closed? cable Is condition of high voltage cable good (not brittle, burnt, or cracked)? Reset high limit the Y79 with the appropriate G600 Ignition controls (contact Johnson Controls Technical Support). Is spark gap 0.1 in. and located in pilot gas stream? Correct or replace pilot burner Is spark electrode ceramic cracked? Turn supply voltage on pilot burner Operate system several complete cycles End Figure 14: /Y79B Spark, and System Does t Work G Intermittent Pilot Ignition Controls Technical Bulletin 15

16 Start Are pilot valve and main valve connections secured to the proper Y79 terminal and ground? Open thermostat contacts for 30 seconds Close thermostat contacts Connect securely Is 24 VAC present between ground and pilot valve terminals of Y79? Is 24 VAC present between Terminal 1 and ground on the? Wait 30% of the Y79 lockout time. the Y79 with the appropriate G600 ignition control (contact Johnson Controls Technical Support). Correct Is inlet pressure per manufacturer s specifications?! WARNING: Explosion Hazard. Do not use a match to test for presence of gas. Is gas at pilot? Is spark gap 0.1 in. and located in the pilot gas stream? Make sure the pilot line is not kinked or obstructed. Check for a clean orifice. Correct or replace pilot burner Check for drafts. Shield as necessary and check for clean orifice. If OK, replace pilot valve. End Figure 15: /Y79B Spark is Present, but Pilot Does t Light 16 G Intermittent Pilot Ignition Controls Technical Bulletin

17 Start Does spark stay on for more than 30 seconds after pilot lights? Is 24 VAC between Terminal 3 Is inlet gas pressure and ground? per manufacturer s specifications? Correct gas pressure Make sure sensor cable and high voltage cable are separated and not wrapped around any pipe or accessories. Is 24 VAC present between main valve terminal on the Y79 and ground terminal on the? Is sensor cable securely connected to Terminal 4 and flame sensor? Connect securely the Y79 with the appropriate G600 ignition control (contact Johnson Controls Technical Support). Is sensor ceramic cracked? Is main valve wiring securely connected to the main valve terminal on the Y79 and ground? Connect securely sensor Is cable grounded out? Is sensor or sensor connector shorted out to metal surface? Correct main valve Correct Is there continuity and good insulation in the sensor cable? cable Connect DC microammeter between sensor cable terminal and Terminal 4. Observe correct polarity. See Figure 20. Disconnect sensor cable from Terminal 4 Disconnect main valve lead from Terminal 3 A Is DC current 0.2 microamperes or greater with pilot only operation? Check for: - proper gas pressure - clean pilot assembly - tight mechanical and electrical connections If there is no improvement, change the flame sensor length or the orifice size, then perform any necessary turn down tests. End Figure 16: /Y79B Pilot Lights, but Main Burner Does t Come On G Intermittent Pilot Ignition Controls Technical Bulletin 17

18 Start Is system wiring per manufacturer s instructions? Open thermostat contact for 30 seconds Correct wiring Close thermostat contacts and wait 30% of the Y79 lockout time Is a spark present? Is 24 VAC present between Terminal 2 and ground? System was in lockout Is 24 VAC present between Terminal 1 and ground? Determine the reason for lockout. Conduct microamperage test as outlined in Figure 16, starting at A. Turn off supply voltage Is 24 VAC present on secondary of transformer? Connect securely Check the high voltage cable. Is it securely connected to the spark transformer? transformer if proper voltage is present on primary of transformer Reset high limit Is high limit closed? Turn supply voltage on cable Is condition of high voltage cable good (not brittle, burnt, or cracked)? the Y79 with the appropriate G600 ignition control (contact Johnson Controls Technical Support). Is spark gap 0.1 in. and located in pilot gas stream? Correct or replace pilot burner Is spark electrode ceramic cracked? pilot burner End Operate system several complete cycles Turn supply voltage on Figure 17: /Y79A Spark, and System Does t Work 18 G Intermittent Pilot Ignition Controls Technical Bulletin

19 Start Is pilot valve wiring securely connected to Terminal 1 and ground? Connect securely! WARNING: Explosion Hazard. Do not use a match to test for presence of gas. Is inlet gas pressure per manufacturer s specifications? Is gas at pilot? Make sure pilot line is not kinked or obstructed. Check for clean orifice. Correct gas pressure pilot valve Is pilot spark gap 0.1 in. and located in pilot gas stream? Correct or replace pilot Check for drafts. Shield as necessary and check for clean orifice. End Figure 18: /Y79A Spark is Present, but Pilot Will t Light G Intermittent Pilot Ignition Controls Technical Bulletin 19

20 Start Does spark stay on for more than 30 seconds after the pilot lights? Is 24 VAC between Terminal 3 and ground? Is inlet gas pressure per manufacturer s specifications? Correct gas pressure Make sure sensor cable and high voltage cable are separated and not wrapped around any pipe or accessories. Is main valve wiring securely connected to Terminal 3 and ground? Connect securely Is sensor cable securely connected to Terminal 4 and flame sensor? Connect securely main valve Is sensor ceramic cracked? Is cable grounded out? Is sensor or sensor connector shorted out to metal surface? Correct sensor Correct Is there continuity and good insulation in the sensor cable? cable Connect DC microammeter between sensor cable terminal and Terminal 4. Observe correct polarity. See Figure 20. Disconnect sensor cable from Terminal 4 Disconnect main valve lead from Terminal 3 Is DC current 0.2 microamperes or greater with pilot only operation? Check for: - proper gas pressure - clean pilot assembly - tight mechanical and electrical connections If there is not improvement, change the flame sensor length or the orifice size and perform any necessary turn down tests. End Figure 19: /Y79A Pilot Lights, but Main Burner Does t Come On 20 G Intermittent Pilot Ignition Controls Technical Bulletin

21 Y99AU-2 Multimeter Jumper 5 Electrode Pilot Burner Assembly Positive Lead to Terminal 4 Negative Lead to Flame Sensor Figure 20: Meter Hookup to Measure Flame Sensing Circuit G Intermittent Pilot Ignition Controls Technical Bulletin 21

22 tes 22 G Intermittent Pilot Ignition Controls Technical Bulletin

23 tes G Intermittent Pilot Ignition Controls Technical Bulletin 23

24 tes Controls Group 507 E. Michigan Street FAN 121 P.O. Box 423 Installation Sheets Manual Milwaukee, WI Printed in U.S.A. 24 G Intermittent Pilot Ignition Controls Technical Bulletin

G67 Intermittent Pilot Ignition Controls

G67 Intermittent Pilot Ignition Controls Heating Line Product Guide 435.0 Ignition Controls Section Product Bulletin G67 Issue Date 1098 G67 Intermittent Pilot Ignition Controls The G67 Intermittent Pilot Ignition (IPI) Control is used to automatically

More information

E Series CE/AGA Approved Intermittent Pilot Ignition Control

E Series CE/AGA Approved Intermittent Pilot Ignition Control Installation Instructions Issue Date June 12, 2014 E Series CE/AGA Approved Intermittent Pilot Ignition Control Application The E Series CE/AGA Approved Intermittent Pilot Ignition Control is a safety

More information

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing Installation Sheets Manual 121 Gas Ignition Controls and Devices Section J Technical Bulletin Issue Date 0398 Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

More information

INSTALLATION INSTRUCTIONS FOR MODEL UNIVERSAL INTERMITTENT PILOT IGNITION CONTROL

INSTALLATION INSTRUCTIONS FOR MODEL UNIVERSAL INTERMITTENT PILOT IGNITION CONTROL INSTALLATION INSTRUCTIONS FOR MODEL 26108 UNIVERSAL INTERMITTENT PILOT IGNITION CONTROL Figure 1 Model 26108 Universal Intermittent Pilot Ignition Control Application The model 26108 Universal Intermittent

More information

L62GB BASO Safety Shutoff Device

L62GB BASO Safety Shutoff Device Installation Instructions Issue Date March 5, 2013 L62GB BASO Safety Shutoff Device Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These instructions are

More information

GWA. Control Supplement. Spark-Ignited Pilot System. Gas-Fired Water Boilers. Hazard definitions. Contents. Page 1 Boiler wiring...

GWA. Control Supplement. Spark-Ignited Pilot System. Gas-Fired Water Boilers. Hazard definitions. Contents. Page 1 Boiler wiring... GWA Gas-Fired Water Boilers Control Supplement Spark-Ignited Pilot System Hazard definitions Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause

More information

SERIES & VAC Microprocessor Based Direct Spark Ignition Control with or without Combustion Blower Relay FEATURES APPLICATIONS

SERIES & VAC Microprocessor Based Direct Spark Ignition Control with or without Combustion Blower Relay FEATURES APPLICATIONS SERIES 35-60 & 35-61 24 VAC Microprocessor Based Direct Spark Ignition Control with or without Combustion Blower Relay 35-60,-61 FEATURES 24 VAC microprocessor based DSI control Pressure switch monitoring

More information

Gas fired boiler Control Supplement

Gas fired boiler Control Supplement LGB Gas fired boiler Control Supplement LGB-4-4 & LGB-5-5 Universal Control System -5 Series 2 Propane gas Contents Installation... 2 Conversion (Natural/Propane)... 2 Gas piping...3 Wiring...4 Operating

More information

VLV49A Series Universal Replacement Gas Valve

VLV49A Series Universal Replacement Gas Valve Technical Bulletin VLV Issue Date 0100 VLV49A Series Universal Replacement Gas Valve To Terminal 1 To Terminal 3 To Terminal 5 or Ground Blue Red Black Grommet Screw B Screw A Valve Inlet Pilot Tap Connection

More information

S89E,F Direct Spark Ignition Control Module

S89E,F Direct Spark Ignition Control Module S89E,F Direct Spark Ignition Control Module FEATURES PRODUCT DATA APPLICATION The Honeywell S89E,F Direct Spark Ignition Control Modules control the ignition sequence and gas control operation in direct

More information

Y99AW-1 Flame Simulator

Y99AW-1 Flame Simulator Installation Sheets Manual 121 Miscellaneous Products and Accessories Section Y Technical Bulletin Issue Date September 30, 2014 Flame Simulator Figure 1: Flame Simulator Application The Flame Simulator

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Natural gas CSD Control System Part Number 55010-681/0304 Please read this page first Hazard definitions To the installer: The following terms are

More information

XII Service and Maintenance WARNING

XII Service and Maintenance WARNING XII Service and Maintenance WARNING THE BOILER CONTAINS REFRACTORY CERAMIC FIBER, A POSSIBLE HUMAN CARCINOGEN. USE A NIOSH APPROVED RESPIRATOR WHEN SERVICING HIGH-TEMPERATURE INSULATION AND GASKET MATERIALS.

More information

Gas fired boiler Control Supplement

Gas fired boiler Control Supplement LGB Gas fired boiler Control Supplement LGB-4-4 & LGB-5-5 Universal Control System -5 Series 2 Natural gas Contents Installation... 2 Gas piping...3 Wiring... 4 Operating instructions... 6 Verification

More information

Q3450/Q3453A,B,C,D,E,F,G and Q3480B,C SmartValve System Pilot Burners

Q3450/Q3453A,B,C,D,E,F,G and Q3480B,C SmartValve System Pilot Burners Q0/QA,B,C,D,E,F,G and Q80B,C SmartValve System Pilot Burners APPLICATION PRODUCT DATA These SmartValve System pilot burners provide pilot flame ignition and sensing for SV9XX/SV96XX Systems. They consist

More information

Q314 and Q327A Pilot Burners

Q314 and Q327A Pilot Burners TRADELINE Q314 and Q327A Pilot Burners Application Pilot burners provide main burner ignition for standing pilot natural and LP gas systems. Used with a thermocouple to provide automatic pilot safety control.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C03, 36C10, 36C13 and 36D34 Combination Gas Valves (24 Volt, 120 Volt and.750 Volt Models) INSTALLATI INSTRUCTIS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW

More information

SECTION II: SPECIFICATIONS

SECTION II: SPECIFICATIONS INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-47675-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

LGB. Control Supplement. Gas fired boiler. CSD-1 Control System. Series 2 Propane gas. Contents

LGB. Control Supplement. Gas fired boiler. CSD-1 Control System. Series 2 Propane gas. Contents LGB Gas fired boiler Control Supplement LGB-6 to LGB-20 Series 2 Propane gas CSD-1 Control System Contents I. New installation... 2 II. Existing installation... 4 III. Water and steam trim components...

More information

INSTALLATION DATA UNIVERSAL ELECTRONIC IGNITION GAS VALVE UNI-KIT

INSTALLATION DATA UNIVERSAL ELECTRONIC IGNITION GAS VALVE UNI-KIT INSTALLATION DATA 720-079 UNIVERSAL ELECTRONIC IGNITION GAS VALVE UNI-KIT INTERMITTENT PILOT HOT SURFACE DIRECT SPARK The Robertshaw 720-079 Universal Electronic Ignition Gas Valve Uni-Kit is de signed

More information

BGC278 Series BASOTROL CE Approved Gas Valve

BGC278 Series BASOTROL CE Approved Gas Valve Installation Instructions BGC278 Issue Date April 1, 2013 BGC278 Series BASOTROL CE Approved Gas Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

COMMERCIAL GAS-FIRED BOILERS

COMMERCIAL GAS-FIRED BOILERS Supplement Manual to 321078-000 Instruction Manual COMMERCIAL GAS-FIRED BOILERS MODELS: UP-FLOW MODELS HW 420/520/670 SERIES 302/303 25589 Highway 1 McBee, SC 29101 WITH ELECTRONIC INTERMITTENT PILOT IGNITION

More information

Control. Line. Thermostat. Pressure Switch Hot Surface Element. Output Ratings. Inducer Fan. Hot Surface Element. Gas Valve Rating.

Control. Line. Thermostat. Pressure Switch Hot Surface Element. Output Ratings. Inducer Fan. Hot Surface Element. Gas Valve Rating. SERIES 35-67 24 VAC Proven Hot Surface Ignition Control with Combustion Blower Relay Microprocessor Based 35.67.02 FEATURES Proven pressure switch input Combustion fan output 24/120/240 VAC hot surface

More information

CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER

CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER A steam boiler has been built and installed at a factory for the provision of process steam. The following lists the requirements used in the commissioning

More information

Previously the Johnson module was used, then the Fenwal module replaced it. Note the Ground terminals The THS 2 Terminal The PV 1 Terminal The MV 3

Previously the Johnson module was used, then the Fenwal module replaced it. Note the Ground terminals The THS 2 Terminal The PV 1 Terminal The MV 3 Previously the Johnson module was used, then the Fenwal module replaced it. Note the Ground terminals The THS 2 Terminal The PV 1 Terminal The MV 3 Terminal The Blind 6 terminal The Sense 4 terminal and

More information

V4297S Normally Open Vent Valve

V4297S Normally Open Vent Valve V4297S Normally Open Vent Valve FEATURES PRODUCT DATA APPLICATION The V4297S provides the vent function in a double block and bleed configuration. The valve is part of the Honeywell Integrated Valve Train

More information

PRODUCT DESCRIPTION. Pilot Burner

PRODUCT DESCRIPTION. Pilot Burner PRODUCT DESCRIPTION Elyxxon pilot burners have their applications in flare installations, and internal combustion applications. It is used to support the main flame. When the main flame is extinguished

More information

PART 12: TROUBLESHOOTING

PART 12: TROUBLESHOOTING PART 12: TROUBLESHOOTING A. ELITE HEATING BOILER ERROR CODE If any of the sensors detect an abnormal condition or an internal component fails during the operation of the Elite Heating Boiler, the display

More information

EGH-85 & 95 Series 4 & 5 PFG-6 & 7 Series 6 & 7

EGH-85 & 95 Series 4 & 5 PFG-6 & 7 Series 6 & 7 EGH-85 & 95 Series 4 & 5 PFG-6 & 7 Series 6 & 7 Control Supplement Standing Pilot Boilers Controls must only be installed by a Weil-McLain distributor or other qualified installer/service technician in

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........

More information

Model 7586. Description / Applications. Intermittent Pilot Gas Ignition Control

Model 7586. Description / Applications. Intermittent Pilot Gas Ignition Control PARTS & ACCESSORIES Model 7586 Intermittent Pilot Gas Ignition Control Description / Applications The Beckett GeniSys Intermittent Pilot Gas Ignition Control is a 24 Vac gas ignition and safety control.

More information

Hot Dawg Troubleshooting Guide

Hot Dawg Troubleshooting Guide Hot Dawg Troubleshooting Guide Troubleshooting HD Direct Spark Units IMPORTANT The use of this manual is specifically intended for a qualified installation and service agency. All installation and service

More information

Norcold Repair Guide Models 865,866,868

Norcold Repair Guide Models 865,866,868 A008 Norcold Repair Guide Models 865,866,868 Section 5 Table of Contents Page 5-2 General Information and Specifications 5-2 Operating Limits - All Models 5-2 Ratings 5-3 Electrical Connections - 12 Volts

More information

Installation Instructions Part No thru

Installation Instructions Part No thru Replacement Inducer Motor Assembly Kit Cancels: New Installation Instructions Part No. 326628-760 thru 326628-765 IIK 312A-45-3 6-02 NOTE: Read the entire instruction manual before starting the installation.

More information

EF100T SUPPLEMENT TO INSTALLATION/ OPERATING INSTRUCTIONS MANUAL G

EF100T SUPPLEMENT TO INSTALLATION/ OPERATING INSTRUCTIONS MANUAL G EF100T399-875 SUPPLEMENT TO INSTALLATION/ OPERATING INSTRUCTIONS MANUAL 238-44445-00G WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property

More information

Read the instructions before use. This control must be installed in accordance with the rules in force.

Read the instructions before use. This control must be installed in accordance with the rules in force. 9.957.821 001 8 2 0 N O V A Read the instructions before use. This control must be installed in accordance with the rules in force. English 3-13 APPLICATION The 820 Nova Millivolt combination gas control

More information

LGB. Gas fired boiler. Control Supplement. LGB-6 to LGB-20 Series 2 Natural gas. CSD-1 Control System. Contents

LGB. Gas fired boiler. Control Supplement. LGB-6 to LGB-20 Series 2 Natural gas. CSD-1 Control System. Contents LGB Gas fired boiler Control Supplement LGB-6 to LGB-20 Series 2 Natural gas CSD-1 Control System Contents I. Installation... 2 II. Gas piping... 4 III. Water and steam trim components... 5 IV. Wiring...

More information

VK41..E, T GAS CONTROLS WITH THROTTLE VALVE FOR AUTOMATIC IGNITION SYSTEMS SPECIFICATIONS DESCRIPTION INSTRUCTION SHEET

VK41..E, T GAS CONTROLS WITH THROTTLE VALVE FOR AUTOMATIC IGNITION SYSTEMS SPECIFICATIONS DESCRIPTION INSTRUCTION SHEET VK41..E, T GAS CONTROLS WITH THROTTLE VALVE FOR AUTOMATIC IGNITION SYSTEMS INSTRUCTION SHEET SPECIFICATIONS Models VK4100 series: VK4105 series: Suffix E: Suffix T: 220/0 Vrac, 50 Hz. two automatic shut

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION 2TC03700124 FURNACE TWINNING CONTROL Supersedes: 650.69-N2.7V (395) 650.69-N2.7V (1196) FOR USE WITH THE FOLLOWING FURNACE MODELS: ALL DIRECT DRIVE BLOWER MODEL GAS FURNACES ALL

More information

A319 Electronic Temperature Control

A319 Electronic Temperature Control FANs 216, 125, 195 Product/Technical Bulletin A319 Issue Date 0396 A319 Electronic Temperature Control The A319 Series is a line voltage, single-stage electronic temperature control with Single-Pole, Double-Throw

More information

V4295A,S; V8295A,S Solenoid Gas Valves

V4295A,S; V8295A,S Solenoid Gas Valves V4295A,S; V8295A,S Solenoid Gas Valves INSTALLATION INSTRUCTIONS FEATURES APPLICATION The electrically operated V4295A, S and V8295A, S Solenoid Gas Valves control the flow of natural and LP (liquefied

More information

AC Electrical System Tests Sign-Off Sheet. STEP Initials Date

AC Electrical System Tests Sign-Off Sheet. STEP Initials Date AC Electrical System Tests Hot Skin Test Prepare Documentation? Make sure shore line is plugged into 120VAC source? Set VOM to AC voltage scale? Place one probe on a bare metal surface of the RV (i.e.,

More information

Gas Burner Controls. Flame supervision is accomplished with an ionization probe. The demand for heat is visually indicated (on the top of the unit).

Gas Burner Controls. Flame supervision is accomplished with an ionization probe. The demand for heat is visually indicated (on the top of the unit). 7 620 ISO 9001 Gas Burner Controls LGC22... Gas burner controls for the startup, control and supervision of single-stage atmospheric gas burners in intermittent operation, with pilot burners 250 W and

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

LGB. Gas fired boiler. Control Supplement. Flame Guardian WMBC-1A. RM7895C Controller Electronic Pilot System IRI. Contents

LGB. Gas fired boiler. Control Supplement. Flame Guardian WMBC-1A. RM7895C Controller Electronic Pilot System IRI. Contents LGB Gas fired boiler Control Supplement Flame Guardian WMBC-1A RM7895C Controller Electronic Pilot System IRI Contents Installation... 2 Gas piping... 4 Wiring... 5 Startup... 9 Sequence of Operation...

More information

VA-8050 Electric Valve Actuator Floating Control, 50 lb. Force

VA-8050 Electric Valve Actuator Floating Control, 50 lb. Force VA8050 Electric Valve Actuator Floating Control, 50 lb. Force 14 490 2, Rev. B Product Bulletin VA8050 Issue Date February 2016 The VA8050 synchronous, motordriven actuator provides floating control of

More information

LXi Heat Exchanger, Heat Exchanger Tube Assembly, and Heat Exchanger Baffles, Polymer, Replacement Kits

LXi Heat Exchanger, Heat Exchanger Tube Assembly, and Heat Exchanger Baffles, Polymer, Replacement Kits H0295400 Rev B LXi Heat Exchanger, Heat Exchanger Tube Assembly, and Heat Exchanger Baffles, Polymer, Replacement Kits WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor

More information

HOW TO CHECK THE BLOWER MOTOR HOW TO CHECK THE VACUUM/PRESSURE SWITCH

HOW TO CHECK THE BLOWER MOTOR HOW TO CHECK THE VACUUM/PRESSURE SWITCH http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html PowerVent Training Manual SVC 500 (Rev 2) HOW TO CHECK THE BLOWER MOTOR In normal operation, the controls check for a closed pressure

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin AdvantagePlus Troubleshooting

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin AdvantagePlus Troubleshooting TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373 AdvantagePlus Troubleshooting When first diagnosing an AdvantagePlus, check the following: If the unit is not operating, is the power

More information

S8910U Universal Hot Surface Ignition Module

S8910U Universal Hot Surface Ignition Module SUPER TRADELINE Universal Hot Surface Ignition Module INSTALLATION INSTRUCTIONS Installation Instructions for the Trained Service Technician. APPLICATION The SUPER TRADELINE Universal Hot Surface Ignition

More information

S8910U Universal Hot Surface Ignition Module

S8910U Universal Hot Surface Ignition Module S8910U Universal Hot Surface Ignition Module FEATURES PRODUCT DATA Replaces many White-Rodgers, Robertshaw and Honeywell hot surface ignition models. (See Tables 2, 3, and 4.) For 120 Vac (up to 5.0A)

More information

EUROSIT. Read the instructions before use. This control must be installed in accordance with the rules in force.

EUROSIT. Read the instructions before use. This control must be installed in accordance with the rules in force. 9.957.631 139 630 EUROSIT Read the instructions before use. This control must be installed in accordance with the rules in force. English 3-10 APPLICATION The 630 Eurosit is a combination gas control with

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. HIGH ALTITUDE / NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES,00-7,000 FT. ONLY HIGH ALTITUDE KIT/PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools

More information

Signature Command. Troubleshooting Guide

Signature Command. Troubleshooting Guide Signature Command Troubleshooting Guide SC Set Up Master Switch on Ticking from Motor And beep No Check for power See page 3 Pilot and Igniter Check Page 5 1 red every 2 Seconds, power Vent turned on See

More information

VR46../VR86..E, EA, EB, T, TA AND TB

VR46../VR86..E, EA, EB, T, TA AND TB VR46../VR86..E, EA, EB, T, TA AND TB COMACT COMBINATION GAS CONTROLS WITH THROTTLE VALVE SECIFICATIONS INSTRUCTION SHEET Subject to change without notice. All rights reserved ALICATION controls have been

More information

Norcold Repair Guide

Norcold Repair Guide 1 40 Norcold Repair Guide Table of Contents Page 2 Safety Information 4 General Information and Specifications 5 12 Volts and 120 Volts Connections 6 Operation 7 Accessories-6000/6100 Series 8 Location

More information

HE-6300 Series Wall-mount Humidity Transmitter with Temperature Sensor

HE-6300 Series Wall-mount Humidity Transmitter with Temperature Sensor FANs 216, 1628.3 Product/Technical Bulletin HE-6300 Issue Date 0499 HE-6300 Series Wall-mount Humidity Transmitter with Temperature Sensor The HE-6300 houses both a humidity transmitter and a temperature

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

36G Gas Control Product Information

36G Gas Control Product Information Single Stage 6G Two Stage 6G 6G Gas Control Product Information The 6G (Gemini) combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

LGBGas fired boiler Control Supplement

LGBGas fired boiler Control Supplement LGBGas fired boiler Control Supplement Flame Guardian WMBC-1A RM7895C Controller Electronic Pilot System IRI Contents I. Installation... 2 II. Gas piping... 5 III. Wiring... 5 IV.Startup... 10 V. Sequence

More information

Installation Instructions Part No thru

Installation Instructions Part No thru Replacement Inducer Housing Kit Cancels: New IIK-310-45-4 6-02 Installation Instructions Part No. 326627-751 thru 326627-755 Note: Read the entire instruction manual before starting the installation. SAFETY

More information

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators Installation Instructions Part No. 34-636-1433, Rev. D Issued February 12, 2008 Supersedes November 29, 2006 Applications The M9102

More information

36J Gas Control Product Information

36J Gas Control Product Information Single Stage 6J Two Stage 6J 6J Gas Control Product Information The 6J combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent

More information

GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER

GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER Control Manual And Troubleshooting Guide P/N# 4000604, Rev. E [03/03] - TABLE OF CONTENTS - Table Of Contents... - Important Safety Information... 3 3

More information

SERVICE MANUAL MG 12, 24, 36, 48 AND 60 GAS RESTAURANT RANGE MODEL MG12

SERVICE MANUAL MG 12, 24, 36, 48 AND 60 GAS RESTAURANT RANGE MODEL MG12 SERVICE MANUAL GAS RESTAURANT RANGE MG 12, 24, 36, 48 AND 60 MODEL MG12 MG24 MG36 MG48 MG60 ML-52549 ML-52514 ML-52522 ML-52523 ML-52524 MG12 VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696,

More information

Northwest RV Supply Manual Compliments of Printed From

Northwest RV Supply Manual Compliments of Printed From 1 2 Norcold Repair Guide Table of Contents Page 2 Safety Information 4 General Information and Specifications 5 12 Volts and 120 Volts Connections 6 Operation 7 Accessories-6000/6100 Series 8 Location

More information

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators FEATURES PRODUCT DATA Push-in clip, split nut, and adapter assembly for easy pilot burner installation. Q335 Spade or quick-connect

More information

WMWFM Series Hydronic Heating Air Handler

WMWFM Series Hydronic Heating Air Handler WMWFM Series Hydronic Heating Air Handler Installation Operation Maintenance The WMWFM series unit is designed for permanent up flow, counter flow, or horizontal left/right airflow installation. Installation

More information

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?

More information

INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS PFS CSA CERTIFIED VENTED GLOWING GAS EMBERS LOG SET TESTED TO GAS ANSI LOG Z21.60 SET - 2012 WARNING: If you do not follow

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 2TC03700124 FURNACE TWINNING CONTROL 035-14572-000 REV. A (800) For use with the following furnace models: ALL SINGLE STAGE DIRECT DRIVE BLOWER MODEL GAS FURNACES

More information

VR46.5V(A/B)/VR86.5V(A/B) SERIES

VR46.5V(A/B)/VR86.5V(A/B) SERIES VR46.5V(A/B)/VR86.5V(A/B) SERIES COMPACT COMBINATION GAS CONTROLS WITH INTEGRATED 1:1 GAS/ AIR REGULATOR FOR AUTOMATIC IGNITION SYSTEMS SPECIFICATIONS INSTRUCTION SHEET Subject to change without notice.

More information

INSTALLATION & MAINTENANCE MANUAL FOR PVI FIREPOWER BG400 GAS BURNER 140,000 thru 1,400,000 Btu/h

INSTALLATION & MAINTENANCE MANUAL FOR PVI FIREPOWER BG400 GAS BURNER 140,000 thru 1,400,000 Btu/h INSTALLATION & MAINTENANCE MANUAL FOR PVI FIREPOWER BG400 GAS BURNER 140,000 thru 1,400,000 Btu/h CARBON MONOXIDE WARNING: CAUTION: IMPROPER COMBUSTION MAY CAUSE SERIOUS INJURY. PVI recommends a seasonal

More information

GAS PRO CO 2 GAS GENERATOR (PROPANE)

GAS PRO CO 2 GAS GENERATOR (PROPANE) WARNING Use only with propane gas. Propane can cause fire or explosion if handled improperly. Installation to be done by qualified personnel only. Unit gets hot when operating, DO NOT TOUCH. Keep flammable

More information

A F. AF-1000 Series Manual Gas Control Valve A M E R I C A N F L A M E

A F. AF-1000 Series Manual Gas Control Valve A M E R I C A N F L A M E A M E R I C A N F L A M E A F AF-1000 Series Manual Gas Control Valve APPLICATION The AF-1000 Manual Gas Control Valve is designed for use in gas in hearth products, wall mount furnaces, and space heating

More information

PVI ATMOSPHERIC GAS WATER HEATERS TYPICAL CONSTRUCTION MANUFACTURED AFTER JANUARY 1, 1994

PVI ATMOSPHERIC GAS WATER HEATERS TYPICAL CONSTRUCTION MANUFACTURED AFTER JANUARY 1, 1994 PVI ATMOSPHERIC GAS WATER HEATERS TYPICAL CONSTRUCTION MANUFACTURED AFTER JANUARY 1, 1994 Figure 2-1 1. Vent stack * 7. Control switch(es) and fuse(s) 2. Draft diverter (hood) 8. Gas valve 3. Flue damper

More information

ICM 271. Replacement Description

ICM 271. Replacement Description ICM 271 Fan Control Center Replacement Description The ICM271 Fan Control Center is a solid state control designed and engineered for the replacement market. The ICM271 is designed specifically to replace

More information

V8200, VR8200, VR8201 Continuous Pilot Combination Gas Controls

V8200, VR8200, VR8201 Continuous Pilot Combination Gas Controls V8200, VR8200, VR820 Continuous Pilot Combination Gas Controls APPLICATION These continuous pilot combination gas controls are used in gas-fired appliances that have up to 200 cfh capacity of natural gas.

More information

http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html HOW TO CHECK THE BLOWER MOTOR The blower motor on the Guardian PowerVent is responsible for all fresh combustion air entering the combustion

More information

GAS PRO CO 2 GAS GENERATOR (NATURAL GAS)

GAS PRO CO 2 GAS GENERATOR (NATURAL GAS) WARNING Use only with natural gas at 5" to 7" W.C. pressure. Natural gas can cause fire or explosion if handled improperly. Installation to be done by qualified personnel only. Unit gets hot when operating,

More information

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS - SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS - SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS - SAFETY INSTRUCTIONS This manual contains important safety and operating instructions for models SUL100, SUL120, ESUL100 and ESUL120. Do not expose

More information

Fire Pit Inserts (Automated Operation) Operating and Maintenance Instructions

Fire Pit Inserts (Automated Operation) Operating and Maintenance Instructions Table of Contents Section 1: Gas and Electric Requirements... 1 Section 2: Installation... 2 Section 3: Burner Setup and Adjustment... 7 Section 4: Maintenance... 9 Section 5: Operation... 10 Operating

More information

Civacon 8130 Optic Rack Monitor System and Associated Equipment

Civacon 8130 Optic Rack Monitor System and Associated Equipment Manual Part Number: 1 Civacon 8130 Optic Rack Monitor Manual Part Number: Table of Contents Section Description Page 1 Product Description... 3 1.1 Products... 4 1.2 Voltage Selection... 4 2 Mounting Diagram...

More information

LESTRONIC II WITH SLIDE-IN TIMER TECHNICIAN SERVICE GUIDE

LESTRONIC II WITH SLIDE-IN TIMER TECHNICIAN SERVICE GUIDE *33366* LESTRONIC II WITH SLIDE-IN TIMER TECHNICIAN SERVICE GUIDE PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS To be able to troubleshoot safely and effectively, it is important to read

More information

PVI FIREPOWER GAS BURNER TYPICAL CONSTRUCTION

PVI FIREPOWER GAS BURNER TYPICAL CONSTRUCTION PVI FIREPOWER GAS BURNER TYPICAL CONSTRUCTION Figure 9-1 1. Burner housing 15. Air switch 29. Orifice location * 2. Air intake 16. Door assembly * 30. Electrode retaining bracket 3. Oil pump opening plug

More information

Air Conditioning Sign-Off Sheet

Air Conditioning Sign-Off Sheet Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate

More information

DSI SERVICE GUIDE DESCRIPTION OPERATING SEQUENCE DUOTHERM

DSI SERVICE GUIDE DESCRIPTION OPERATING SEQUENCE DUOTHERM DUOTHERM DSI SERVICE GUIDE FOR FENWALL DIRECT SPARK IGNITION SYSTEMS 05-15 FOR 12 VOLT DC UNITS AND 05-16 FOR 24 VOLT AC UNITS AS USED WITH DUO-THERM 659, 660, 661 AND 900 SERIES HEATERS. DESCRIPTION In

More information

XP Series. Preventive Maintenance Guide. 480 V Models. PCXP-xxkW-yyyA-zzV Felland Road, Suite 116 Madison, WI USA. Power Designers USA LLC

XP Series. Preventive Maintenance Guide. 480 V Models. PCXP-xxkW-yyyA-zzV Felland Road, Suite 116 Madison, WI USA. Power Designers USA LLC XP Series 480 V Models PCXP-xxkW-yyyA-zzV Preventive Maintenance Guide 4005 Felland Road, Suite 116 Madison, WI 53718 USA Power Designers USA LLC MAN-220002-00 REV A TABLE OF CONTENTS SAFETY PRECAUTIONS...

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

1F79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

1F79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning CONTENTS Installation Instructions for Heating & Air Conditioning 1F79 n- Programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........

More information

Single-Stage Thermostat Install Guide

Single-Stage Thermostat Install Guide Single-Stage Thermostat Install Guide Model # NP110 Made in China 37-7581 GUIDE CONTENTS Preparations... 3 Thermostat details... 4 Removal of your old thermostat... 5 Mounting and wiring your new thermostat...

More information

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers SUPERSEDES: Revision D Dated January 6, 2009 #5401179-REV E PLANT ID 001-3907 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending Instruction Sheet LTR - Low Water Cutoff for Hot Water

More information

FSP5075A Flame Amplifier Module

FSP5075A Flame Amplifier Module FSP5075A Flame Amplifier Module PRODUCT DATA The flame amplifier module amplifier and relay circuitry combine to provide such safety features as safe-start check, safety shutdown and rapid flame failure

More information

Fire and Water Bowls (Automated Operation) Operating and Maintenance Instructions

Fire and Water Bowls (Automated Operation) Operating and Maintenance Instructions Table of Contents Section 1: Gas and Electric Requirements... 1 Section 2: Installation... 2 Section 3: Burner Setup and Adjustment... 8 Burner Adjustment... 9 Section 4: Maintenance... 11 Section 5: Operation...

More information