SEMASPEC Test Method for Determination of Filter Flow Pressure Drop Curves for Gas Distribution System Components
|
|
- Agnes Harmon
- 7 years ago
- Views:
Transcription
1 SEMASPEC Test Method for Determination of Filter Flow Pressure Drop Curves for Gas Distribution System Components Technology Transfer B-STD
2 and the logo are registered service marks of, Inc. 1996, Inc.
3 SEMASPEC Test Method for Determination of Filter Flow Pressure Drop Curves for Gas Distribution System Components February 22, 1993 Abstract: This SEMASPEC establishes a test method for preparing a flow rate vs. pressure drop curve for filters being considered for installation into a high-purity gas distribution system. Application of this test method is expected to yield comparable data among components tested for the purposes of qualification for installation. This document is in development as an industry standard by Semiconductor Equipment and Materials International. When available, adherence to the SEMI standard is recommended. Keywords: Equipment, Eqipment Performance, Gas Filters, Facilities, Gas Distribution Systems, Specifications, Components, Component Testing, Flow Rates, Pressure Authors: Jeff Riddle Approvals: Jeff Riddle, Project Manager Venu Menon, Program Manager Jackie Marsh, Director of Standards Program Gene Feit, Director, Contamination Free Manufacturing John Pankratz, Director, Technology Transfer Jeanne Cranford, Technical Information Transfer Team Leader
4
5 1 SEMASPEC # B-STD SEMASPEC Test Method for Determination of Filter Flow Pressure Drop Curves for Gas Distribution System Components 1. Introduction Semiconductor cleanrooms are serviced by high-purity gas distribution systems. This document presents a test method that may be applied for the evaluation of one or more components considered for use in such systems. 1.1 Purpose The purpose of this document is to define a method for testing components being considered for installation into a high-purity gas distribution system. Application of this test method is expected to yield comparable data among components tested for the purposes of qualification for this installation This document establishes a test method for preparing a flow rate versus pressure drop curve for filters. 1.2 Scope This procedure applies to clean filters including those cartridges of metal, ceramic and membrane construction. The pressure drops for integral housing/cartridge combination units are determined as a single set of values. For housings with removable filter cartridges, the flow curves of the housing and cartridge are determined separately. 1.3 Limitations For separable filtration units, a single cartridge pressure drop value cannot be combined to give the pressure drop value for an extended length cartridge, due to the common outlet port This method is written with the assumption that the operator understands the use of the apparatus at a level equivalent to six months of experience This method is written to test a filter under normal operating conditions. It does not prescribe a procedure for reverse flow testing since operation of the filter in this manner is not recommended by the manufacturers. 2. Reference Documents American Society of Mechanical Engineers Performance Test Code PTC , "Applications." Part II of "Fluid Meters, Interim Supplement on Instruments and Apparatus." 3. Terminology 3.1 CDA clean, dry air. 3.2 filter cartridge the filtration element. 3.3 filter housing the shell that contains the filter cartridge. 3.4 filtration unit fhe assembly consisting of a filter cartridge and housing. Examples are an integral unit, in which the filter cartridge and element are not separable, and a separable unit, in which the filter cartridge and housing can be disassembled.
6 2 3.5 psi pounds per square inch. 3.6 psia pounds per square inch absolute. 3.7 psid pounds per square inch differential. 3.8 psig pounds per square inch gauge. 3.9 scfm standard cubic feet per minute slpm standard liters per minute standard conditions kpa, 0.0 C (14.73 psia, 32 F). 4. Test Protocol 4.1 Test Conditions Precautions This test method may involve hazardous materials, operations, and equipment. This test method does not purport to address the safety considerations associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and determine the applicability of regulatory limitations before using this method Test pressure is to be incremental, up to the maximum rated pressure Test flow rate is to be incremental up to the maximum rated flow, at the maximum rated pressure drop Test temperature is to be maintained between 18 C (64 F) and 26 C (78 F). 4.2 Apparatus Materials Nitrogen or CDA filtered to <0.02 micrometer is required Instrumentation A pressure regulator, a test filter, a downstream flow regulating valve, a flow meter, and several upstream and differential pressure transducers or gauges (0.1 psi sensitivity) are required Instruments shall be calibrated regularly per manufacturer's instructions Setup and Schematic Construct a test stand for the measurement of gas flow rates for known pressure drops across the test filter as shown in the schematic drawing (See Figure 1). Nitrogen gas supply is filtered by an electronics grade high purity point-of-use gas filter before it is delivered to the test filter through a pressure regulator and a throttling valve. The test specimen is isolated between two throttling valves to allow for control of the inlet pressure to the test component. Inlet pressure is measured immediately upstream of the test filter by a pressure gauge. Pressure drop across the test specimen is measured by an electronic differential pressure transducer capable of reading 0.1 kpa across the test device. Flow measurement is carried out downstream of the throttling valve located downstream of the test piece by rotometers.
7 Temperature of the gas is measured at two locations by thermocouples installed downstream of the test piece. The thermocouples are connected to a digital readout unit to directly display and read the filter outlet gas temperature Table 2 gives the piping requirements, standard test section configuration. (Section 5.3) Figure 2 gives the recommended pressure connection to be followed in constructing the test apparatus. (See Section 5.4). 3 Figure 1 Filter Flow Curve Test Schematic
8 4 4.3 Test procedures Integral Filtration Unit Assemble the filtration unit into the test apparatus. (See Figure 1.) Set the inlet pressure using the pressure regulator to 10% of the filter s maximum rated inlet pressure or to 103 kpa (15 psig), whichever is less. Pressure is read on the inlet pressure gauge Adjust the flow rate using the regulating valve to give 10% of the maximum rated flow. Flow rate is read on the flow meter Read and record the inlet temperature, inlet pressure, pressure drop across the filter, ambient temperature, ambient pressure and flow rate corrected for upstream pressure Repeat steps in Sections and at 25%, 50%, 75%, and 100% of the maximum rated flow Repeat steps in Sections through at inlet pressures of 207 kpa (30 psig), 621 kpa (90 psig), and 1379 kpa (200 psig). Also test the filter at higher pressures up to the maximum rated pressure. It is recommended that the filter be tested at pressures of 33%, 67%, and 100% of the filter s maximum pressure rating, with tests being limited by the sensitivity of the differential pressure device Separable Filtration Unit Filter Housing Assemble the filter housing into the test apparatus Set the inlet pressure using pressure regulator to 10% of the housing's maximum rated inlet pressure or to 103 kpa (15 psig), whichever is less. Pressure is read on the inlet pressure gauge Adjust the flow rate using the regulating valve to give 10% of the maximum rated flow. Flow rate is read on the flow meter Read and record the temperature, pressure, pressure drop and flow rate corrected for upstream pressre Repeat steps in Sections and at 25%, 50%, 75%, 100% of the filter cartridge's maximum rated flow Repeat steps in Sections through at inlet pressures of 207 kpa (30 psig), 621 kpa (90 psig), and 1379 kpa (200 psig). Also, it is desirable to test the filter at higher pressures, up to the maximum rated pressure. It is recommended that the filter be tested at pressures of 33%, 67%, and 100% of the filter's maximum pressure rating, with tests being limited by the sensitivity of the differential pressure device.
9 4.3.3 Separable Filtration Unit Assembled Cartridge and Housing Assemble the filter cartridge into the filter housing Assemble the filtration unit into the test apparatus Set the inlet pressure using the pressure regulator to 10% of the filter s maximum rated inlet pressure, or to 103 kpa (15 psig), whichever is less. Pressure is read on the inlet pressure gauge Adjust the flow rate using the regulating valve to give 10% of the maximum rated flow. Flow rate is read on the flow meter Read and record the temperature, pressure, pressure drop, and flow rate Repeat steps in Sections and at 25%, 50%, 75%, and 100% of the maximum rated flow Repeat steps in Sections through at inlet pressures of 207 kpa (30 psig), 621 kpa (90 psig), and 1379 kpa (200 psig). Also, it is desirable to test the filter at higher pressures, up to the maximum rated pressure. It is recommended that the filter be tested at pressures of 33%, 67%, and 100% of the filter's maximum pressure rating, with tests being limited by the sensitivity of the differential pressure device The flow curve for the filter cartridge is determined by subtracting the pressure drop of the housing from the pressure drop of the assembled filtration unit at respective flow rates and test pressures. 4.4 Data Analysis Complete Table 3. (See Section 5.) 5
10 6 5. Illustrations 5.1 See Figure 1 for filter flow test schematic diagram. Table 1 Symbols Used T Temperature (K) degrees Kelvin P Pressure (kpa g) kilopascal, gauge q Flow rate (Nm 3 /hr) normal cubic meters per hour P(H) Differential (kpa d) kilopascal, differential pressure of housing P(T) Differential (kpa d) kilopascal, differential pressure of total P(C) Differential (kpa d) kilopascal, differential pressure of cartridge
11 7 Table 2 Piping Requirements-Standard Test Sections A *, ** B C D Standard Test Section Configuration At least 18 nominal pipe diameters of straight pipe 2 nominal pipe diameters of straight pipe. 6 nominal pipe diameters of straight pipe At least 1 nominal pipe diameter of straight pipe *Dimension A may be reduced to 8 nominal diameters if straightened vanes are used. Design of straightening vanes can be found in ASME Performances Test Code PTC Applications. Part 2 of Fluid Meters, Interim Supplement on Instruments and Apparatus. **If an upstream flow disturbance consists of two ells in series and they are in different planes, dimension A must exceed 18 nominal pipe diameters unless straightened vanes are used. See Section 3.2 for definition of the test specimen. Figure 2 Recommended Pressure Connection 1 1 Reprinted by permission. Copyright Instrument Society of America From ANSI/ISA-S
12 8 Table 3 Filter Flow Pressure Drop Curves (page 1 of 2) Filtration Unit Identification Test Number Date Operator Name Barometric Pressure Pa INTEGRAL FILTRATION UNIT T (K) P (kpa-g) P(T) (kpa-d) Flow Meter Reading (units) q (Nm 3 /hr) 1ST 2ND 3RD ETC
13 9 Table 3 Filter Flow Pressure Drop Curves (page 2 of 2) HOUSING WITH CARTRIDGE INSTALLED T (K) P (kpa-g) P(T) (kpa-d) Flow Meter Reading (units) q (Nm 3 /hr) CARTRIDGE PRESSURE DROP P(CARTRIDGE) = P(T) - P(H) q (Nm 3 /hr) P(T) (kpa-d) P(H) (kpa-d) P(Cartridge) (kpa-d) NOTICE: DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MAKES NO WARRANTIES AS TO THE SUITABILITY OF THIS METHOD FOR ANY PARTICULAR APPLICATION. THE DETERMINATION OF THE SUITABILITY OF THIS METHOD IS SOLELY THE RESPONSIBILITY OF THE USER.
14
15
16 Technology Transfer 2706 Montopolis Drive Austin, TX
LifeASSURE PFS Series Filter Cartridge Integrity Testing
LifeASSURE PFS Series Filter Cartridge Integrity Testing Introduction Integrity testing is the end user s method of confirming the structural integrity of a membrane filter before and after use. It is
More informationMethod to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition
Supplement to TESTING STANDARD Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition [NOTE: This supplement incorporates testing and calculations to determine heat source friction
More informationValve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection. www.swagelok.com
www.swagelok.com Valve Sizing Te chnic al Bulletin Scope Valve size often is described by the nominal size of the end connections, but a more important measure is the flow that the valve can provide. And
More informationUnderstanding Pressure and Pressure Measurement
Freescale Semiconductor Application Note Rev 1, 05/2005 Understanding Pressure and Pressure Measurement by: David Heeley Sensor Products Division, Phoenix, Arizona INTRODUCTION Fluid systems, pressure
More informationSIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
More informationKNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
More informationSIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)
(IFGS) SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2006 International Fuel Gas
More informationEquivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409
Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationSIZING AND CAPACITIES OF GAS PIPING
CALIFORNIA RESIDENTIAL CODE MATRIX ADOPTION TABLE APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state
More informationTechnical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements
Technical & Sizing Bulletin for Meriam LFEs Laminar Flow Elements What they are... Meriam Laminar Flow Elements are gas volume rate of flow differential producers operating on capillary flow principles.
More informationInstalling a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
More informationUser s Manual Laminar Flow Elements
501:440-13 User s Manual Laminar Flow Elements 10920 Madison Avenue Cleveland, Ohio 44102 Tel: 216.281.1100 email:meriam@meriam.com Web:www.meriam.com 1 TABLE OF CONTENTS Subject Page Introduction... 3
More informationTurbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
More informationBASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER
BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER Valve size often is described by the nominal size of the end connections but a more important measure is the flow that
More informationFLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases
FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY RESULT IN INJURY TO YOU OR DAMAGE TO
More informationNORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
More informationVogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15
The Connection Bulletin for Forged Steel Flow Control Valves CB 15 Flow Control Division Forged Steel Flow Control Valves GRADUATED DIAL AND INDICATOR FULLY GUIDED V-PORT THROTTLING DISC AND INTEGRAL HARD
More informationMichael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
More informationHYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed
More informationCartridge Filter Application Notes
Industrial Water Purification (800) CAL-WATER Cal Water 1961 Petra Lane Placentia, CA 92870 FAX: (714) 792-0794 Web Page / Email: www.cal-water.com Cartridge Filter Application Notes Cal Water offers a
More informationSurge Pressure in Plumbing Pipe Materials
Surge Pressure in Plumbing Pipe Materials Prepared for Plastics Pipe Institute, Inc. 15 Decker Court, Suite 825 Irving, Texas 7562 Prepared by NAHB Research Center 4 Prince George s Blvd. Upper Marlboro,
More informationChapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service
BP Lower 48 Onshore Operations Safety Manual Page 4.19 1 Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service I. General Requirements A. After motor vehicle accidents and underground excavation
More informationTECHNICAL BRIEF. Microfluor II Filter Cartridge Integrity Testing. Introduction. Forward flow integrity test. 1. Definition
TECHNICAL BRIEF Microfluor II Filter Cartridge Integrity Testing Introduction The integrity test is the End User s method to confirm the structural integrity of a membrane filter before and after use.
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationCentrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
More informationFUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801
FUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801 INTRODUCTION The majority of all gas measurement used in the world today is performed by two basic
More informationFORMATION DAMAGE AND WELL TREATMENT SYSTEM
FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation
More informationFisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
More informationValidation of process gas systems
Validation of Process Gas Systems By Jeff Hargroves Alza Corporation Validation of process gas systems involve documenting the expected system behavior, and verifying that the system performs as expected.
More informationCHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.
CHAPTER II REGULATOR AND RELIEF DEVICES This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192. BASIC CONCEPT In understanding
More informationACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation
ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation Ohio Medical Corporation 1111 Lakeside Drive Gurnee, IL 60031 Phone: (800) 448-0770 Fax: (847) 855-6304 info@ohiomedical.com
More informationSentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
More informationFreescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX4080D.
Freescale Semiconductor Integrated Silicon Pressure Sensor + On-Chip Signal Conditioned, Temperature Compensated and Calibrated The series piezoresistive transducer is a state-of-the-art monolithic silicon
More informationT U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
More informationA practical guide to restrictive flow orifices
Safetygram 46 A practical guide to restrictive flow orifices Restrictive flow orifices (RFOs) installed in cylinder valve outlets provide a significant safety benefit for users of hazardous gases, especially
More informationApplication Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges
Application Note USTR 805 Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges 0 Table of Contents Table of Contents 1. Important Recommendations...1 1.1 Installation
More informationEASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
More informationSTEPS TO COMPRESSOR SELECTION & SIZING
COMPRESSORS 04/99 CB-207 STEPS TO COMPRESSOR SELECTION & SIZING I II Understand the Application What is the compressor supposed to do? Find Out the Details Gas, pressures, temperatures, capacities, etc.?
More informationThermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
More informationTechnical Information
Determining Energy Requirements - & Gas Heating & Gas Heating and gas heating applications can be divided into two conditions, air or gas at normal atmospheric pressure and air or gas under low to high
More informationFlow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
More informationSoil Suction. Total Suction
Soil Suction Total Suction Total soil suction is defined in terms of the free energy or the relative vapor pressure (relative humidity) of the soil moisture. Ψ = v RT ln v w 0ω v u v 0 ( u ) u = partial
More informationTEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL
Project No. 148 TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL Prepared for: Mr. Ted Tiberi Arid Technologies, Inc. 130 North LaGrange Rd. LaGrange, IL 60525 Prepared
More informationEffects of Atmospheric Pressure on Gas Measurement
Effects of Atmospheric Pressure on Gas Measurement Class # 1390.1 March 2012 / White paper by Denis Rutherford Regional Sales Manager Central US Schneider Electric Telemetry & Remote SCADA Solutions 6650
More informationSELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS TPZ Engine Air Intake Shut Down Valves (Combined Automatic Overspeed and Air Pressure Operated Shut Down Bendix Types) SELECTION, APPLICATION & MAINTENANCE Valve Numbers TPZ-101
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More informationStandard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
More informationSEMICONDUCTOR TECHNICAL DATA
SEMICONDUCTOR TECHNICAL DATA Order this document by MPX5050/D The MPX5050 series piezoresistive transducer is a state of the art monolithic silicon pressure sensor designed for a wide range of applications,
More informationReference Manual. Pressure/Temperature Compensated Flow (P_PTComp) Version 3.1
Reference Manual Rockwell Automation Library of Process Objects: Pressure/Temperature Compensated Flow (P_PTComp) Version 3.1 Important User Information Read this document and the documents listed in the
More informationWATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS
GAP.14.1.2.2 A Publication of Global Asset Protection Services LLC WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS INTRODUCTION A hydrant or other large-volume flow test is necessary for proper water
More informationTechnical Bulletin 144. Air Volume Conversions. by:
Technical Bulletin 144 Air Volume Conversions by: Environmental Dynamics International Published: 4/2007 DISCLAIMER Technical Bulletins are presented as a service by Environmental Dynamics International
More informationDaniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.
DAN-LIQ-TG-44-rev0208 February 2008 Daniel Liquid Control Valves Technical Guide www.daniel.com Daniel Measurement and Control Theory, Principle of Operation and Applications This brochure has been prepared
More informationUltipleat High Flow Filter System
Data Sheet PIUFFSENa Ultipleat igh Flow Filter System Description The Ultipleat igh Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside-to-outside flow pattern.
More informationVacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
More information289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
More informationStack Sampling Stack sampling or source sampling
Stack Monitoring Stack Sampling Stack sampling or source sampling may be defined as a method of collecting representative samples of pollutant laden air/gases at the place of origin of pollutants to determine
More informationFreescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX5500.
Freescale Semiconductor Integrated Silicon Pressure Sensor + On-Chip Signal Conditioned, Temperature Compensated and Calibrated Series Pressure Rev 7, 09/2009 0 to 500 kpa (0 to 72.5 psi) 0.2 to 4.7 V
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationHOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
More informationAKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
More informationApplication of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
More informationTypes 66R and 66RR Low-Pressure Relief Valves
November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling
More informationQuiz On Information Learned From Chapter 1
Quiz On Information Learned From Chapter 1 1. Most hydraulic circuits are designed by: A. mechanical engineers. B. fluid power engineers. C. fluid power distributor salesmen. 2. Atmospheric pressure at
More informationRITTER Multiple Sonic Nozzle Calibration System
RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases
More informationOpen Channel Diffusers
Open Channel Diffusers Application Information: Open channel diffusers are used to increase mixing and absorbance efficiency of a chemical solution into the process water. Specifically designed penetrations
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationChapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
More informationCO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
More informationUltrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014
Ultrasonic Gas Meters for Industrial and Commercial Applications Ohio Gas Association Technical Seminar March 27-28,2014 Objectives Technology Operation Benefits Applications Approvals and Standards Products
More information1301 Series High-Pressure Regulators
1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk
More informationTHE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM
THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM ETV JOINT VERIFICATION STATEMENT TECHNOLOGY TYPE: APPLICATION: TECHNOLOGY NAME: COMPANY: BAGHOUSE FILTRATION PRODUCTS CONTROL OF PM 2.5 EMISSIONS BY BAGHOUSE
More informationThreaded Inline Air Heaters
Threaded Inline Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow
More informationHeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance (200-1000 scfm models)
INNOVATIVE COMPRESSE AIR SOLUTIONS COMPRESSE AIR SOLUTIONS eatsink TRUE-CYCLING REFRIGERATE COMPRESSE AIR RYERS 150 2,400 SCFM Independently Verified Performance (200-1000 scfm models) Stainless Steel
More informationFundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
More informationMeriam Instrument LFE Data Sheet
1. AIR FLOW IN SCFM AT STANDARD CONDITIONS OF 29.92 AND 70 F. SCFM = Standard cubic feet per minute. ACFM = Actual cubic feet per minute CFM = Cubic feet per minute. When the flowing gas is air and the
More informationLaminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
More informationThe Fundamentals of Gas Flow Calibration
The Fundamentals of Gas Flow Calibration Application Note Introduction Understanding the fundamentals of gas flow calibration is essential for evaluating calibration systems, estimating the magnitude of
More informationRevised April (May) 2015
Section 19.0 Cross Connection Control Policy 19.1 Responsibility 19.1.1 The Elkhart Water Utility has the responsibility to supply safe, potable water from the source to the point of delivery defined as
More informationRPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:
GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in
More informationSANITARY GRAVITY SEWER LINE TESTING. B. Section 02732 CCTV Inspection of Gravity Sewer Lines
PART 1 GENERAL 1.1 SECTION INCLUDES A. Low Pressure Air Test B. Deflection Test 1.2 RELATED SECTIONS A. Section 02730 Sanitary Gravity Sewer Lines B. Section 02732 CCTV Inspection of Gravity Sewer Lines
More informationPowers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationModel 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
More informationHow To Order A Direct Flow Air Cleaner
Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today
More informationElement D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
More informationSUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration
SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration FBSPAKMSAENf Technical Information SUPRApak M Series-SA filtration units are turn-key systems designed for use with
More informationTechnical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
More information6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationwww.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 19 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
More informationR-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014
R-Value and of PEX and PE-RT TR-48/2014 Foreword R-VALUE AND THERMAL CONDUCTIVITY OF PEX AND PE-RT TR-48/2014 This technical report was developed and published with the technical help and financial support
More informationGrant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
More informationThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
More informationUNDERSTANDING REFRIGERANT TABLES
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING REFRIGERANT TABLES INTRODUCTION A Mollier diagram is a graphical representation of the properties of a refrigerant,
More informationProduct Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
More informationGas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
More informationMONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
More informationGeneral Purpose Thermal Mass Flowmeter Model 4140/4143
Mass Flowmeters General Purpose Thermal Mass Flowmeter Model 4140/4143 Operation and Service Manual 1980383, Revision D January 2009 Mass Flowmeters General Purpose Thermal Mass Flowmeter Model 4140/4143
More informationDruck PV 62x pneumatic/hydraulic pressure stations
GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300
More informationFAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?
What Is a Cross-Connection? A cross-connection is a direct arrangement of piping that allows the potable (safe drinking) water pipe to be connected to a pipe supply that contains a contaminant or pollutant.
More information