1 igital Temperature Controller E5EN Compact, Intelligent Temperature Controller Reduced panel depth of only 78 mm. Accepts thermocouple, non-contact temperature sensor and analog input, or platinum RT. Auto-tuning and self-tuning available; functions can be used simultaneously. Heating or heating/cooling control. Event input option allows multiple set point selection and Run/Stop function. Water-resistant construction (NEMA 4X, equivalent to IP66). Conforms to UL, CSA, and IEC safety standards as well as CE marking. 3-year warranty. Ordering Information J Temperature Controllers Stock Note: Shaded models are normally stocked. Optional communications and event input boards are shown on the following page. Size Power Alarm Output Heater Model supply points burnout voltage alarm Thermocouple input Platinum RT input 1/8 IN 1 to 24 3 Relay No E5EN-R3MTC-5 AC1-24 E5EN-R3MP-5 AC (W) x VAC Yes E5EN-R3HMTC-5 AC1-24 E5EN-R3HMP-5 AC (H) x 78() mm Voltage (for No E5EN-Q3MTC-5 AC1-24 E5EN-Q3MP-5 AC1-24 driving i SSR) Yes E5EN-Q3HMTC-5 AC1-24 E5EN-Q3HMP-5 AC1-24 Current No E5EN-C3MTC-5 AC1-24 E5EN-C3MP-5 AC V 3 Relay No E5EN-R3MTC-5 AC/C24 E5EN-R3MP-5 AC/C24 AC/C Yes E5EN-R3HMTC-5 AC/C24 E5EN-R3HMP-5 AC/C24 Voltage (for No E5EN-Q3MTC-5 AC/C24 E5EN-Q3MP-5 AC/C24 driving i SSR) Yes E5EN-Q3HMTC-5 AC/C24 E5EN-Q3HMP-5 AC/C24 Current No E5EN-C3MTC-5 AC/C24 E5EN-C3MP-5 AC/C24 Note: 1. When the heating and cooling function is used, the number of alarm outputs will be reduced to The heating and cooling function and the heater burnout alarm will disable one of the alarm outputs for each function used. A--82 igital Temperature Controller E5EN
2 J Accessories (Order Separately) Stock Note: Shaded models are normally stocked. escription Specifications Model Computer communications RS-2C E53-AK1 boards RS-485 E53-AK3 Event input board For remote set point and Run/Stop functionality E53-AKB Current transformer; order 5 A load, 5.8 mm hole dia. E54-CT1 only if using heater burnout alarm function 5 A load, 12 mm hole dia. E54-CT3 Terminal cover (supplied Provides finger protection from terminals (VE16 part 1) E53-COV11 with controller) Software For setup and monitoring; requires optional computer communications board Thermo Tools (See Note) Note: Contact Omron for current version information. Specifications J Ratings Supply voltage 1 to 24 VAC, 5/6 Hz 24 VAC, 5/6 Hz/24 VC Operating voltage range 85% to 11% of rated supply voltage Power consumption 9VA 5VA/4W Sensor input Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum resistance thermometer: Pt1, JPt1 Non-contact temperature sensor: 1 to 7_C, 6 to 12_C, 115 to 165_C, 16 to 26_C Voltage input: to 5 mv Control Relay output SPST-NO, 25 VAC, 5 A (resistive load), electrical life: 1, operations output t Voltage output 12 VC +15% / --2% (PNP), max. load current: 4 ma, with short-circuit protection circuit Current output 4 to 2 ma C, load: 6 Ω max., resolution: approx. 2,6 Alarm output Control method Setting method Indication method Ambient operating temperature Storage temperature Ambient humidity J Characteristics Indication accuracy Hysteresis Proportional band (P) SPST-NO, 25 VAC, 3 A (resistive load), electrical life: 1, operations PI or ON/OFF control igital setting using front panel keys 7-segment digital display and single-lighting indicator. Character height: PV: 14. mm; SV: 9.5 mm -- 1_C to55_c (14 F to 131 F) with no condensation or icing -- 25_C to65_c (--13 F to 149 F) with no condensation or icing 25% to 85% RH Thermocouple: ±.5% of indicated value or ±1_C, whichever greater, ±1 digit max. (See Note) Platinum resistance thermometer: ±.5% of indicated value or ±1_C, whichever greater, ±1 digit max. Analog input: ±.5% FS±1 digit max. CT input: ±5% FS±1 digit max..1 to EU (in units of.1 EU).1 to EU (in units of.1 EU) Integral time (I) to 3999 s (in units of 1 s) erivative time () to 3999 s (in units of 1 s) Control period 1to99s(inunitsof1s) Manual reset value.% to 1.% (in units of.1%) Alarm setting range Sampling period Insulation resistance ielectric strength to 9999 (decimal point position depends on input type) 5 ms 2 MΩ min. at 5 VC 2 VAC, 5 or 6 Hz for 1 min between different charging terminals Note: The indication of K thermocouples in the -2 to 13 C range, and T and N thermocouples at a temperature of -1 C or less, and U and L thermocouples at any temperature is ±2 C±1 digit maximum. The indication of B thermocouples at a temperature of 4 C or less is unrestricted. The indication of R and S thermocouples at a temperature of 2 C orlessis±3 C±1 digit maximum. (This table continues on the next page.) igital Temperature Controller E5EN A--83
3 Specifications Table -- continued from previous page Vibration resistance 1 to 55 Hz, 1 m/s 2 for 2 hours each in X, Y and Z directions Shock resistance 3 m/s 2, 3 times each in 3 axes, 6 directions (relay: 1 m/s 2 ) Weight Approx. 31 g; mounting bracket: Approx. 1 g Protective structure Front panel: NEMA 4X for indoor use (equivalent to IP66), rear case: IP2, terminals: IP Memory protection EEPROM non-volatile memory (number of writes: 1,) EMC Emission Enclosure: EN5511 Group 1 class A Emission AC Mains: EN5511 Group 1 class A Immunity ES: EN61-4-2: 4 kv contact discharge (level 2) 8 kv air discharge (level 3) Immunity RF-interference: ENV514: 1 V/m (amplitude modulated, 8 MHz to 1 GHz) (level 3) 1 V/m (pulse modulated, 9 MHz) Immunity Conducted isturbance: ENV5141: 1 V (.15 to 8 MHz) (level 3) Immunity Burst: EN61-4-4: 2 kv power-line (level 3) 2 kv I/O signal-line (level 4) Approved standards UL3121-1, CSA22.2 No. 14, E.B.142C Conforms to EN581-2, EN582-2, EN611-1 (IEC611-1) Conforms to VE16/part 1 (Finger Protection) when the terminal cover is mounted. J Communications Specifications Transmission path connection Communications method (See Note 1) Synchronization method Baud rate Transmission code ata bit length (See Note 2) Stop bit length (See Note 2) Error detection Flow control Interface (See Note 1) Retry function Communications buffer Multiple points RS-485 (two-wire, half duplex)/rs-2c Start-stop synchronization 1,2/2,4/4,8/9,6/19,2 bps ASCII 7or8bits 1or2bits Vertical parity (none, even, odd) Frame check sequence (FCS): with SYSMAC WAY Block check character (BCC): with CompoWay/F Not available RS-485/RS-2C Not available 4 bytes Note: 1. RS-2C communications are only supported for the E5AN and E5EN models. 2. The baud rate, data bit length, stop bit length, or vertical parity can be individually set using the communications setting level. J Current Transformer Ratings Model E54-CT1 E54-CT3 Max. continuous heater current 5 amps 12 amps (See Note 1) ielectric strength Vibration resistance 1, VAC (for 1 min) 5 Hz, 98 m/s 2 (1G) Weight Approx g Approx. 5 g Accessories Armature: 2; Plug: 2 Note: 1. Use within the max heater current rating of controller table shown below. J Heater Burnout Alarm Max. heater current Heater current value display accuracy Single-phase 5 A AC ±5% FS ±1 digit max. Heater burnout alarm setting range.1 to 49.9 A (in units of.1 A) (See Note 1) Min. detection ON time 19 ms (See Note 2) Note: 1. The heater burnout alarm is always OFF if the alarm is set to. A and always ON if the alarm is set to 5. A. 2. No heater burnout detection or heater current value measurement is possible if the control output (heat) is ON for less than 19 ms. A--84 igital Temperature Controller E5EN
4 Input Types (selectable with input jumper connector) Thermocouple Input (field K1 K2 J1 J2 T1 T2 E L U1 U2 selectable) (See Note) Set value Range C --2 to 1,3 F --8 to 2,372 Input (field selectable) (See Note) -2 to to to to 1, to to to to 752 N R S B K1 to 7 C to to 1,562 to6 1 to 85 to 1,1 K6 to 12 C 212 to 1,562 K115 to 165 C -2 to to 752 K16 to 26 C to to 752 Set value Range C -2 to 1,3 to 1,7 to 1,7 1 to 1,8 to 9 to 12 to 165 to 26 to5 mv to 9999 Note: F -8 to 2,372 to 3,92 Setting number is factory--set to (K1). to 3, to 3,272 to 194 to 248 to 9 to to (scalable) Platinum Resistance Thermometer (RT s) Input Pt1 Pt1 Pt1 JPt1 JPt1 (field selectable) Set value Range C -2 to to 5.. to to 5.. to 1. Range F -3 to to 9. to to 9.. to 21. Nomenclature Operation indicators Temperature unit No.1 display No.2 display Operation indicators Mode key Up key Level key own key igital Temperature Controller E5EN A--85
5 imensions Unit: mm (inch) 48 (1.89) 11.5 (.45) 99.4 (3.91) 78 (3.7) 96 (3.78) 112 (4.41) 93.3 (3.67) Panel Cutouts Mounted Separately Group Mounted number of units (1.89 number of units --.14) 12 (4.72) min. 92 (3.62) (3.62) Group mounting does not allow waterproofing (3.62) Recommended panel thickness is 1 to 8 mm (.4 to.31 inch). Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers when they are group mounted.) To mount the E5EN so that it is waterproof, apply the waterproof packing to the E5EN. When two or more E5ENs are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature range in the specifications. A--86 igital Temperature Controller E5EN
6 J Current Transformer (Sold Separately) E54-CT1 E54-CT3 21 (.83) (.23) dia. 2.8 (.11) dia. 3 (1.18) 12 dia (.9) dia. 9 (.35) 25 (.98) 1.5 (.41) 7.5 (.3) 4 (1.57) x 4 (1.57) 3 4 (1.57) Two, 3.5 dia. Two, M3 (depth: 4) 1 (.39) 15 (.59) 3 (1.18) 3 (1.18) J TERMINAL COVER E53-COV11 13 (.51) 6.5 (.26) dia (3.63) 1.5 (.41) 6.5 (.26) 8 (.31) Wiring Terminals The voltage output (control output) is not electrically isolated from the internal circuits. When using a grounded thermocouple, do not connect the control output terminals to ground. If the control output terminals are connected to the ground, errors will occur in the measured temperature values as a result of leakage current. Standard insulation is applied to the power supply I/O sections. If reinforced insulation is required, connect the input and output terminals to a device without any exposed current-carrying parts or to a device with standard insulation suitable for the maximum operating voltage of the power supply I/O section. Event input Contact inputs Non-contact input Current output Voltage output Relay output Input power supply Control output 1 Alarm output ALM3/Control output 2 Heater burnout detection input Communications RS--2C RS S B R A SG on t Alarm output ALM2 Analog input OR output of ALM1/Heater burnout igital Temperature Controller E5EN A--87
7
8 Cat. No. H31-E3-1 6/4 Specifications subject to change without notice Printed in USA
The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.
Digital Temperature Controller Compact and Intelligent Temperature Controller Auto-tuning and self-tuning available. Can auto-tune even during execution of self-tuning Heating or heating/cooling control
More informationMultipoint Temperature Controller E5ZE
Multipoint Temperature Controller E5ZE Compact, Easy-to-mount Multipoint Temperature Controller (Casing) Compact, Easy-to-use, Board-type Multipoint Temperature Controller (Open) Easy-to-mount, user-friendly
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationMultifunction Digital Timer
Multifunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationAuto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
More informationCount input Display Time range 999999.9h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black
R Self-Powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features H Large display with 8.6 mm (0.338 in) height H Available with backlit LCD H PNP/NPN DC voltage available H
More informationTLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
More informationInput signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationProgrammable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationTemperature Controller USER S MANUAL
Cat. No. H100-E1-04A E5CN Temperature Controller USER S MANUAL E5CN Temperature Controller User s Manual Revised July 2003 iv Notice: OMRON products are manufactured for use according to proper procedures
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationVroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
More informationHMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More informationProcess controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line
BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationUser Manual Auto Tuning PID Temperature Controller
User Manual Auto Tuning PID Temperature Controller TUPC-T series (Applicable for accurate controls of Temperature) TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationMeter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More information650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More information1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
More informationProduct Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationTemperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual
Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please
More information650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
More informationSpecifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
More informationDurant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.
Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X
More information#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) 876-4697 FAX:(82-32) 876-4696 http://www.hynux.com E-mail: sdt@hyelec.co.kr
#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(8-3) 876-4697 FAX:(8-3) 876-4696 http://www.hynux.com E-mail: sdt@hyelec.co.kr MA01E50110 Recorder & Temperature Controller RT9 INSTRUCTION MANUAL Thank
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationDelta Temperature Controller User Manual
Delta Temperature Controller User Manual Foreword The user manual details the process of using Delta DT series temperature controllers step by step for beginners to easily set up all kinds of parameters
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationHFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More information+ A + + - B V B - - + + + NO NC V COM - - - PV PV
+ - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationChrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationEnergy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More information2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
More informationE8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
More informationSmart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
More informationControls for fan coil units and cassettes
Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationWE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g
New Product News FA Wireless LAN Unit WE70 Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g Construct an Ideal Wireless LAN System for FA Applications! The FA Wireless
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationVert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table
Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample
More information