1 Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating heating and ventilation system performance For calculating comfort indices PMV, PPD and DR For calculating heat stress indices WBGT and required sweat rate For calculating ET * For displaying measurement data and calculated indices as graphs in exportable formats For long-duration (weeks) monitoring of the time history of thermal parameters For logging data from third party transducers with analog outputs As front end for a central data logger system FEATURES: Complies with: ISO 7730/CEN 27730; ISO 7726; ISO 7243/CEN 27243; ASHRAE 55; SAE J2234 Modular system incorporating four slots for simultaneous connection of up to 12 transducers Four modules available: Comfort Module UA 1276, Heat Stress Module UA 1277, Dry Heat Loss Module UA 1278 and Analog Interface Module UA 1346 Operates as both a stand-alone and an on-line instrument Data can be read and displayed on-line, from a memory dump after off-line measurement, or from a disk file Data is stored in spreadsheet format and can be re-used to calculate other indices Applications software runs under Windows and supports Clipboard function for graphs Input for up to 6 analog signals (V or ma) Analog output of six measured values (V) The Thermal Comfort Data Logger Type 1221 enables you to evaluate the thermal comfort of indoor climates as well as workplace-related heat stress. The data logger is a black box thermal platform built up modularly with up to four input modules. The Type 1221 can be used in the field to collect data without any additional software or hardware, or it can be used in connection with a PC and Type 7301 software to view data on-line. The Type 1221 is supplied with a battery pack for use in the field. A mains transformer is also available. Applications Software Type 7301 is a software package for use exclusively with Thermal Comfort Data Logger Type Type 7301 software runs under Windows 3.1. The software retrieves data from the 1221 via the RS 232 interface on the host computer. The measured data is shown on the computer screen along with calculations of a number of indices. The Type 1221 is set up via the 7301 software. Measured data and results are stored to disk in spreadsheet format.
2 Hardware Introduction The Type 1221 enables you to measure all the physical parameters necessary to evaluate thermal comfort according to ISO 7730 and ISO 7726, as well as evaluate heat stress according to ISO 7243 and ISO The Type 1221 is built up modularly, allowing installation of up to four input modules. The types of transducers that can be connected depend on the input module; these are described later on in this literature. The Type 1221 can operate as a standalone data logger or on-line together with a PC, where data can be displayed and processed. The Type 1221 also supplies the necessary power to the transducers connected to the modules and controls the measurement. Power Supply The Type 1221 can use two separate power supplies; a battery pack or a mains power supply. The battery pack, depending on the configuration of the Type 1221 and the transducers used, enables up to 18 hours of measurements to be made. A mains power supply fits neatly into the same slot as the battery box, enabling mains power to be used. Fig.1 Application Software Type 7301, running on a PC, provides the user interface for Thermal Comfort Data Logger Type 1221 Set-up Type 1221 The following parameters are set up inside the Type 1221 via the RS 232 interface: You define which, if any, transducer is connected to the sockets. You also decide what measurement data is stored to, or retrieved from, the Type Five types of data are measured: Instantaneous values (i), Mean values (m), Max. values (h), Min. values (l) and the standard deviation (s). Measurement Interval While the transducers for the Type 1221 have a fixed sampling rate, depending on the transducers chosen, a measurement interval of as little as one tenth of a second can be specified in the applications software. Averaging Time This option allows you to specify over how long a period the maximum, minimum, mean values and standard deviation are to be calculated. Automatic Measurements The start and stop times for the measurement are entered, enabling the Type 1221 to operate as a self-contained, stand-alone instrument. Both before and after measurement the Type 1221 is in a passive state. This ensures that there is power available from the battery pack when required. Data Format When measurement data is to be exported, the file format that best suits your spreadsheet, or other word-processing software, can be specified. Interface The Type 1221 comes complete with an RS 232 serial interface socket. This interface is used to transfer measurement data from the data logger to the PC and to set up the Type 1221 from the PC. All measurement data is transferred in spreadsheet format, which makes it easy to use with PC software packages. Two Modes of Operation Stand-alone Once the measurement set-up has been defined for the Type 1221 and the transducers, the PC can be disconnected, allowing the Type 1221 to operate as a stand-alone unit. All the measurement data from the transducers is transferred to the Type 1221 and stored in its internal memory, which can, for example, store up to one week s measurement data (when a 10 minute measurement interval is selected). On-line If you wish to display measurement data in real-time, simply retain the PC/1221 connection. The RS 232 interface enables real-time measurement data to be transferred to the PC and displayed on screen as graphs. If on-line data transmission is interrupted, the Type 1221 will continue measuring and store the data internally. When data transmission is restored, the stored data is read out. Data Handling The Type 1221 provides instantaneous measurement data as well as values calculated over a user-defined time window, for the mean, maximum, minimum and standard deviation. All the measurement data is stamped with a time and date tag to aid identification during post-processing. The data is transferred from the data logger in spreadsheet format. 2
3 Comfort Module UA 1276 Dry Heat Loss Module UA1278 Analog Interface Module UA1346 Analog I/O 1 Dry Heat Loss 1 Analog I/O 2 Analog I/O 3 Analog I/O 4 Humidity Analog I/O 5 Analog I/O 6 Air Velocity UA1276 Comfort Module Dry Heat Loss 2 UA1278 Dry Heat Loss Module UA1346 Analog Interface Module This module enables transducers to be connected that will provide measurement data for the majority of the physical parameters required to evaluate thermal comfort. The module has three sockets, enabling a Transducer, a Humidity Transducer and an Air Velocity Transducer to be connected. Heat Stress Module UA1277 This module enables two Dry Heat Loss MM0057 to be connected. The transducer can be operated in the normally heated mode where it measures dry heat loss and equivalent temperature, or in an unheated mode where it measures operative temperature. Due to the power consumption, it is recommended that the number of UA1278 modules fitted in the 1221 is limited to three. If conditions are outside the dry heat loss transducer s direct measurement range, the module will set up a warning flag and predict the result from the measured parameter. This module enables six analog signals to be sampled from six non-specific measuring instruments. The data is sampled, stored and displayed just like data from the other measurement modules. The module has six sockets. Each of which has an analog input and an analog output. The output values are linked to the measured parameters through a user-defined setup. This allows every measured value to be output as a voltage value. When Innova transducers are used the output voltage is linearized. WBGT Radiation UA1277 Heat Stress Module This module is able to connect the transducers that will provide measurement data to evaluate heat stress. The module has three sockets, enabling a Transducer (with a wider measurement range than UA 1276), a WBGT Transducer and a Radiant Asymmetry Transducer to be connected. 3
4 Specifications 1221, UA 1276, UA 1277, UA1278 and UA 1346 DIMENSIONS: Height: 138 mm (5.4 ) Width: 285 mm (11.2 ) Depth: 300 mm (11.8 ) Weight: 4.0 kg (8.8lb.) excl. power supply MEASUREMENT RANGE: for Dry Heat Loss Module UA 1278 (when mains power supply is connected) COMPLIANCE WITH Safety EMC Emission CE-mark indicates compliance with: EMC Directive and Low Voltage Directive. EN (1993) & IEC (1990): Safety requirements for electrical equipment for measurement, control and laboratory use. EN (1992): Generic emission standard. Part 1: Residential, commercial and light industry. FCC Class B limits. EMC Immunity EN (1995): Generic immunity standard. Part 2: Industrial environment. Note: The above is guaranteed using accessories listed in this Product Data sheet only. IEC & IEC68 2 2: Environmental Testing. Cold and Dry Heat. Operating : +5 C to +50 C (+41 F to +122 F)** Storage : -25 C to +70 C (-13 F to +158 F) Cyan shading: t amb >45 C Green shading: t amb <45 C Humidity Enclosure IEC 529: IP 20 IEC : Operating 90% RH (non-condensing at 30 C) Storage 90% RH (non-condensing at 40 C) POWER SUPPLY: Internal Power Supply: plug-in battery pack (ZG 0146) containing 6 IEC R20 alkaline batteries or 6 NiCd rechargeable cells Mechanical IEC68 2 6: Vibration: 0.3mm, 20m/s 2, Hz IEC : Shock: 750 m/s 2 IEC : Bump: 2 x 1000 at 400 m/s 2 External Power Supply (optional): plug-in power supply ZG This is powered from 90 to 264 V AC mains supply at 47 to 65 Hz or 360 to 444 Hz Power Consumption: Type 1221 alone 1.8 W, UA 1276 alone (without transducers) 0.4 W, UA 1277 alone (without transducers) 0.2 W UA 1278 alone (without transducers) 0.4 W Battery Lifetime (typical): 18 hours with alkaline batteries, 9 hours with rechargeable Ni-Cd batteries installed (with one UA 1276 and one UA 1277 installed) 10 hours with alkaline batteries, 5 hours with rechargeable Ni-Cd batteries installed (with one UA 1276 and one UA 1278 installed) Data Transfer: Takes place via the RS 232 interface. Communication Parameters: Baud Rate: 9600 Data Bits: 8 Stop Bits: 1 Parity: none Handshake: Hardwire/switched line DATA STORAGE 1221: Type 1221 can store at least measured values. These values can be instantaneous, mean, standard deviation, maximum or minimum values MODULES: Comfort Module UA 1276 Socket MM0034, MM0035, MM0060 Measurement*** Range (UA1276) 20 to 100 C 0.1 C Humidity MM to 100 C 0.1 C Air Velocity MM0038 See transducer s Product Data Sheet Heat Stress Module UA 1277 Socket MM0034, MM0035, MM0060 Measurement*** Range (UA1277) 40 to 150 C 0.1 C WBGT MM to 150 C 0.1 C Radiation MM0036 See transducer s Product Data Sheet Dry Heat Loss Module UA 1278 Sockets (2) Dry Heat Loss Measurement*** Range (UA1278) MM0057 Operative Temp. 20 to 50 C 0.1 C MM0057 Dry Heat Loss 0 to 205W/m 2 * 0.1W/m 2 * Analog Interface Module UA 1346 Sockets (6) (both input & output) Measurement Range (UA1346) Analog In Voltage: (Current: 0 to 10V 0 to 20mA) 0 to 4V: 1mV 4 to 10V: 2.5mV Analog Out Voltage: 0 to 10V 2.5mV (12 bits) ** If an extended operation range is necessary, contact Innova. * At 0.5 CLO. Only one UA1278 installed *** Indicates the measurement range of the module and not the range for the individual transducers. For additional specifications, see the individual Product Data Sheets for the transducers 4
5 Software Introduction Applications Software Type 7301 enables you to set up the measurement parameters of the Type 1221 Thermal Comfort Data Logger, receive data from the Type 1221 and display this data as graphs on screen. The software is also able to calculate a variety of thermal indices from the measurement data it receives. Measurement data can come from three separate data sources: on-line from 1221, as a block data dump from 1221 or recalled from a file on disk. Data Transfer Two types of data transfer are possible. Data can be transmitted from the 1221 to the PC in real-time via the RS 232 interface, or the Type 1221 can operate as a standalone instrument, dumping stored data to the PC after the measurement has been completed. In the latter case, the RS 232 is disconnected after the 1221 set-up has been communicated to the 1221, and reconnected later when the measurement is finished. Dumped data is handled and displayed in exactly the same way as on-line data. Calculated Indices The software uses the measurement data to calculate a variety of indices for thermal comfort evaluations (PMV, PPD and DR) and for heat stress evaluations (WBGT, required sweat rate and ET*). To provide the greatest flexibility, you decide which indices are to be calculated by the program. Data Storage Data from the Type 1221 is transferred in spreadsheet format. The software stores the measurement data in a file of the same format. This enables it to be used in other programs, if necessary. An additional way to use the data through the applications software is via the clipboard provided by Windows. This enables you to copy graphs displayed by the program, and include them in various word processing programs a useful feature when writing reports. Graphic Displays Measurement data is presented simultaneously in up to three graph display windows (see Fig. 1). Each graph window has an axis which reflects the selected display parameters, and can display up to three curves. The upper graph displays temperature and dry heat loss data, the middle graph displays air velocity data and the lower graph displays the calculated indices. The manner in which the graphs are displayed can be fine-tuned from within each window. Specifications 7301 Supplied on a 3.5 inch, 1.44 MB disk COMPUTER REQUIREMENTS: Hardware: A 386 (20 MHz) processor or better Min. 4 Mbytes of RAM Min. 5 Mbytes of space available on the disk VGA monitor or better (colour monitor recommended) One RS 232 port for communication One RS 232 or mouse port for mouse, which must be installed to use this software One 3.5 inch disk drive (1.44 MB) Software: DOS (version 3.3 to 6.2) and Windows * 3.1 or 3.11 or Windows 95 Interface: RS 232 Communication Parameters: Baud Rate: 9600 Stop Bit: 1 Data Bit: 8 Parity: none Handshake: Hardwire/switched line The communication port is selected from within the software (COM 1 or 2) DATA TRANSFER: Set-up Data: Sends data about the measurement set-up from the software to the Type 1221 Measurement Data: Data is transferred in a spreadsheet format, direct from disk or from the Type 1221.Two types of transfer over the interface are available: block data transfer and on-line transfer. The latter provides up to 10 transmissions of data per second Data Functions: Calculate Indices Display measured and calculated values Store all measured and calculated data on disk PMV-d (Predicted Mean Vote) ** PPD-o (Predicted Percentage of Dissatisfied) # PPD-d (Predicted Percentage of Dissatisfied) ** DR (Draught Rating) WBGT (Wet Bulb Globe ) ET * (Effective ) SR (Required Sweat Rate) TI (Turbulence Intensity) PTD (Plane Radiant Difference) TD (Air Difference) EqT-o (Equivalent ) # EqT-d (Equivalent ) ** RH (Relative Humidity) VP (Vapour Pressure) OOT (Optimal Operative ) Td-d (Comfort Temp. EqT-d) ** GRAPHIC DISPLAYS: (The user defines the units for the measured and calculated values) Up to 3 temperature and dry heat loss curves on same axes Up to 3 air velocity curves on same axes Up to 3 index curves on same axes MEASUREMENT DATA: Calculated Indices: PMV-o (Predicted Mean Vote) # * Windows is a trademark of Microsoft Corporation Windows 95 is a trademark of Microsoft Corporation # Calculated using operative temperature transducer ** Calculated using dry heat loss transducer 5
6 Ordering Information Type 1221: Thermal Comfort Data Logger Includes the following accessories: Type 7301: Application Software for Type1221 ZG 0146: Battery box Instruction Manual Basic System Requirements Requires one or more of these modules: UA 1276: Comfort Module UA 1277: Heat Stress Module UA 1278: Dry Heat Loss Module UA 1346: Analog Interface Module WL 0946: Configured Systems Type 3710: RS 232 Cable (25- to 25-pin) Basic Thermal Comfort Data Logging System comprises: Type UA MM MM MM MM WL KE UA UA DH x UA0588 Optional Accessories AO 1429: JP 0500: Adaptor Cable for MM0023 to UA1278 Analog Connector (male), 5-pin cable mounting Requires one or more of these transducers: MM 0030: WBGT Transducer MM 0034: Air Transducer MM 0035: Surface Transducer MM 0036: Radiant Asymmetry Transducer MM 0037: Humidity Transducer MM 0038: Air Velocity Transducer MM 0057: Dry Heat Loss Transducer MM 0060: Operative Transducer One of the following cables: WL 0945: RS 232 Cable (25- to 9-pin) ZG 0342: Mains power supply AQ 0157: Charging adaptor DH 0492: Tripod Mounting Adaptor for 3 UA 1347: Tripod Mounting Adaptor for 4 KE 0357: Transducer Carrying Case KE 0401: WBGT Transducer Carrying Case UA 0803: Tripod UA 1348: Tripod Extension Rods (3) UA 0588: Transducer Mounting Adaptor Innova A/S reserves the right to change specifications and accessories without notice Innova A/S Energivej 30, DK-2750 Ballerup, Tel.: (+45) Fax: (+45) Innova has 45 international agents and distributors. For further information about our products or the name of your local contact, please call , or visit our homepage on the Internet at BP
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Smart Energy Control for Building Management & Production Plant
Multipoint Temperature SMS NET Data Logger GSMS NET HV Smart Energy Control for Building Management & Production Plant Max. 8 digital temperature sensors Data communication via SMS and Ethernet Integra
OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface
5 655 Service Tool ACS plant operating software and OCI700 service interface OCI700.1 Service tool for commissioning and the diagnosis of HVAC controllers of the Synco, SIGMAGYR and ALBATROS ranges. Use
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
MultiViu Flex 7 Data Sheet
Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,
OPERATION MANUAL. Model : DW-6063. 99.99 W x 0.01 W, 520.0 W x 0.1 W Power factor, ACV, ACA WATT METER
99.99 W x 0.01 W, 520.0 W x 0.1 W Power factor, ACV, ACA WATT METER Model : DW-6063 Your purchase of this WATT METER marks a step forward for you into the field of precision measurement. Although this
Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012
Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012 OPUS A3 Standard Full Landscape OPUS A3 Standard Full Neutral 1 Order Numbers OPUS A3 STANDARD Full Wachendorff Projektor Landscape
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
IQ151 CONTROLLER DATA SHEET
IQ151 CONTROLLER DATA SHEET The IQ151 is a controller in the Trend range with 64 inputs and 32 outputs. Full DDC (direct digital control) with PID control loops is provided. The output channels may be
Thermal environments. www.swema.com swema@swema.com Tel. +46 8 94 00 90
ISO 7730 Moderate Thermal Environments Thermal environments Swema equipment for the measurement of Moderate Thermal Environments is designed to comply with the standards: ISO7726 - Thermal environments
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
Tracer Summit Web Server
Tracer Summit Web Server Web-based access for the Tracer Summit building automation system March 2003 BAS-PRC014-EN Introduction The Tracer Summit Web Server provides the ability to operate a Tracer Summit
APPLICATION NOTE. Ear Simulator for Telephonometry. Use of Wideband Ear Simulator Type 4195
APPLICATIO OTE Ear Simulator for Telephonometry Use of Wideband Ear Simulator Type 4195 Wideband Ear Simulator Type 4195 has been designed to match the ear simulators in Head and Torso Simulator Type 4128-C
TABLE OF CONTENTS. Specification... 2 Preperation for equipment.3 DP-3810 Indicator..6 Power Supply.6
0 TABLE OF CONTENTS Specification... 2 Preperation for equipment.3 DP-3810 Indicator..6 Power Supply.6 Panel 7 Key Functions 7 LCD Symbol Description 8 Date & time setting procedure 9 Normal weighing procedure
GeoMax GNSS Zenith10 & Zenith20 Series
GeoMax GNSS Zenith10 & Zenith20 Series GeoMax About Us At GeoMax we provide a comprehensive portfolio of integrated solutions by developing, manufacturing and distributing quality construction and surveying
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
PolyGard Gas Controller System DGC-06
PolyGard Gas Controller System DGC-06 DESCRIPTION Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 can monitor
USB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3
Typical Applications Typical Applications Construction Transmitter Assembly Pipe & cable locator transmitter Transmitting active signals for the location of buried pipes and cables High impact ABS Weight
Scout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
Application Server V240 Platform
Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots
Central Communication Unit
Central Communication Unit for LPB/BSB plants Series B OCI6 Central communication unit for the remote operation and supervision of LPB plants with a maximum of 6 LPB/BSB units Use Plant Buildings Operators
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
581 Rapid Transfer Device (RTD) Instruction Manual. Photo of product, with a.5 point black border
581 Rapid Transfer Device (RTD) Instruction Manual Photo of product, with a.5 point black border Part #60-9003-085 Copyright 1995, 2002. All rights reserved, Teledyne Isco, Inc. Revision J, April 20, 2011
Barcode Reader Series BCL 31, BCL 32, BCL 34
P R O D U C T I N F O R M A T I O N Barcode Reader Series BCL 31, BCL 32, BCL 34 BCL 31, BCL 32 and BCL 34: Barcode readers for universal use in conveyor and storage technology. 3 models: numerous advantages.
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1
IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2
D Monitor for Measurement of Speed and Detection of Series D.xxS KEY FEATURES Speed and Monitor with sensor monitoring and self-test function Frequency range 0 Hz 00 khz Analog Output 0/ 0 ma Bright red
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.
Multi- Channel Oven-Datalogger for Accurate Temperature Profiling in the Food Industry. ThermaPro 2 is the latest generation of high accuracy data logging instruments for use in extreme or hostile environments.
Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4
Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless
Multi-Channel Programmable DC Power Supplies
Dual and triple output models with two 30V/1.5A (45W) channels and a 6V/5A (30W) channel on the triple output supply All channels are independently controlled and have isolated outputs for maximum flexibility
WINGLIKE ELECTRONICS CO.,LTD
WINGLIKE ELECTRONICS CO.,LTD SPECIFICATION FOR APPROVAL AC/DC ADAPTOR CUSTOMER: CUSTOMER SPECS INPUT: 100-240V AC 50-60HZ, 5V/2A ADAPTOR OUR MODEL NO.: GM-050200 (UL) E321192 SPECIFICATION NO.: WL1105102
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
PRODUCT DATA. Human Vibration Analyzer Type 4447
PRODUCT DATA Human Vibration Analyzer Type 4447 Brüel & Kjær's Human Vibration Analyzer Type 4447 is a portable system designed for those who work with human vibration and require quick and reliable results
Central Communication Unit
Central Communication Unit for Synco 00 and Synco RXB OZW Central communication unit for the remote operation and supervision of Synco plants. Use Types of plant Types of building Operators The OZW central
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
SIOX input and output system. Technical specification
SIOX input and output system Technical specification Table of Contents Table of Contents Technical specification... 2 Data... 2 SIOX input and output system Technical specification 1 Technical specification
Ensto Chago Master EVM300 and EVM500 Operational description
Pages: 1 (8) Ensto Chago Master EVM300 and EVM500 Operational Pages: 2 (8) Contents 1 What is Ensto EVM... 3 2 EVM versions... 3 2.1 EVM300... 4 2.2 EVM500... 5 3 Technical information... 7 Pages: 3 (8)
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
User's Guide. Vane Thermo-Anemometer Datalogger. Model 451126. Introduction
User's Guide Vane Thermo-Anemometer Datalogger Model 451126 Introduction Congratulations on your purchase of Extech's Thermo-Anemometer Datalogger. This Vane-type Anemometer can indicate Air Velocity in
Nardalert S3 Non-Ionizing Radiation Monitor
Patent Pending Non-Ionizing Radiation Monitor Field Replaceable Sensor Modules Color LCD Display Multi-Color Alarm LED s USB Interface for Data and Charging Interchangeable Lanyard or Belt Clips Comprehensive
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
R60 USB to CAN interface Manual (1.5 EN)
R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Save time and wiring cost with peer-to-peer
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
Power Supply USP-070-B08 USP-070-B10 USP-104-B10 USP-156-B10 Typically 400 nits (cd/m2), at 25 C.
UniStream HMI Panel USP-070-B08, USP-070-B10 USP-104-B10, USP-156-B10 UniStream HMI Panels provide the foundation of an all-in-one PLC + HMI controller. To create an all-inone device, snap a UniStream
Korosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
Cisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10
LonManager and Protocol Analyzers Models 33100-00 and 33100-10 Description The LonManager Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows
ADAM-4561 1-port Isolated USB to RS-232/422/485 Converter User s Manual
ADAM-4561 1-port Isolated USB to RS-232/422/485 Converter User s Manual Part No. 2000456100 Printed in Taiwan Feb. 2001 1.1 Introduction Advantech s ADAM-4561 allows PC users to connect their serial devices
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
M-Bus-Logger Data Logger
Data Logger User Manual Doc.-No.: E102312514074 Bär Industrie-Elektronik GmbH Rathsbergstr. 23 D-90411 Nürnberg Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
On-line Machine Condition Monitoring [The CMS System]
On-line Machine Condition Monitoring [The CMS System] Strategic monitoring control your costs Avoid unplanned downtime Monitor your plant stoppers Early warning maintains profit Efficient and profitable
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
2 1. 5 O pen F ram e Tou c h M on i t or
M TM G T- R TL 2 2 W- A 21.5" RE AR TOU C H MONITOR Trade SpA - Official European Distributor R eo O ar M ount R T L 1 7 3 2 1. 5 O pen F ram e Tou c h M on i t or R TL 2 2 W- A on i t or D at as h eet
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Hydras 3 LT Quick Start
Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL
DLC - Ethernet MANUALE UTENTE USER'S MANUAL
DLC - Ethernet MANUALE UTENTE USER'S MANUAL 06/2004 INDEX 1. Introduction...1 2. Converter Description...2 2.1 Ethernet connector... 3 2.2 Power supply connector... 3 2.3 Serial Rs485 connector... 4 3.
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions
Facility Pilot Server Art. No. : FAPV-SERVER-REG Facility Pilot Server Art. No. : FAPVSERVERREGGB Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically
RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)
S-232 Baud ate Converter CE Model 232BC Documentation Number 232BC-3903 (pn5104-r003) International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton oad -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone
EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input