EMC TEST REPORT REPORT NO.:ECE R
|
|
- Camron Smith
- 7 years ago
- Views:
Transcription
1 EMC TEST REPORT REPORT NO.:ECE R MODEL : YCM-550, YCM-550C, SW-550, SW-560, SW-550C, SW-560C, SW-510, SW-510C, SW-30M, SW-100, SW-130, YCM-560, YCM-560C, YR-516, YCM-515, YCM-512, YC-807, YR-510, YR-510C, YR-520, YR-520C, YC-809, YC-807, YC-301, YR-801, YR-803, YCM-20, YCM-25, YCM-30, YCM-40, YCM-45, YCM-532, YCM-622, YCM-622C, YCM-501, YCM-502, YCM-513, YCM-513C, YCM-525, YR300, YR-600, YR-680, SW-600, SW-680 RECEIVED: Nov. 17, 2010 TESTED: Nov. 18, 2010 to Dec. 01, 2010 APPLICANT: Shenzhen LSVT Co., Ltd. ADDRESS: 5th Floor, 2nd Block, Zhongyuntai Industrial Park, No. 1 Road, Tangtou, Shiyan Street, Bao an District, Shenzhen City ISSUED BY: Shenzhen SETEK Technology Co., Ltd. LAB LOCATION: 1003, C Bldg, Fuyuan Business Trade Center, 44 District Bao an, Shenzhen, China This test report consists of 32 pages in total, it may be duplicated completely for legal use with the approval of the applicant, It should not be reproduced except in full, without the written approval of our laboratory, The test results in the report only apply to the tested sample. SHENZHEN SETEK TECHNOLOGY CO., LTD. Our website: service@setek.com.cn TEL: FAX:
2 Prepared for Address Product Model Trademark : Shenzhen LSVT Co., Ltd. : 5th Floor, 2nd Block, Zhongyuntai Industrial Park, No. 1 Road, Tangtou, Shiyan Street, Bao an District, Shenzhen City : Color Dome Camera : YCM-550, YCM-550C, SW-550, SW-560, SW-550C, SW-560C, SW-510, SW-510C, SW-30M, SW-100, SW-130, YCM-560, YCM-560C, YR-516, YCM-515, YCM-512, YC-807, YR-510, YR-510C, YR-520, YR-520C, YC-809, YC-807, YC-301, YR-801, YR-803, YCM-20, YCM-25, YCM-30, YCM-40, YCM-45, YCM-532, YCM-622, YCM-622C, YCM-501, YCM-502, YCM-513, YCM-513C, YCM-525, YR300, YR-600, YR-680, SW-600, SW-680 : N/A Test Standard : EN : 1995+A1: 1998+A2: 2003 (EN : 2009, EN : 2006, EN : 2006+A1:2009, EN : 2006, EN : 2009, EN :2004) Prepared by Address : Shenzhen SETEK Technology Co., Ltd. : 1003, C Bldg, Fuyuan Business Trade Center, 44 District Bao an, Shenzhen, China Tel: (86-755) Fax:(86-755) Prepared by : (Engineer) Reviewer by : (Project Engineer) Approved by : (Manager) Report Number : ECE R Date of Test : Nov. 18, 2010 to Dec. 01, 2010 Date of Report : Dec. 02, 2010 Page 2 of 32
3 Description Test Report Description TABLE OF CONTENT Page 3 of 32 Page 1. GENERAL INFORMATION Description of Device (EUT) Description of Support Device Test Standards Measurement Uncertainty MEASURING DEVICE AND TEST EQUIPMENT For Power Line Conducted Emission For Radiated Emission Measurement For Harmonic Current / Flicker Measurement For Electrostatic Discharge Immunity Test For RF Strength Susceptibility Test For Electrical Fast Transient /Burst Immunity Test For Surge Immunity Test For Injected Current Susceptibility Test For Magnetic Field Immunity Test For Voltage Dips and Interruptions Test ELECTROSTATIC DISCHARGE IMMUNITY TEST Block Diagram of Test Setup Test Standard Severity Levels and Performance Criterion EUT Configuration Operating Condition of EUT Test Procedure Test Results RF FIELD STRENGTH SUSCEPTIBILITY TEST Block Diagram of Test Test Standard Severity Levels and Performance Criterion EUT Configuration on Test Operating Condition of EUT Test Procedure...14 Test Results ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST Block Diagram of Test Setup Test Standard Severity Levels and Performance Criterion EUT Configuration Operating Condition of EUT Test Procedure Test Result SURGE IMMUNITY TEST Block Diagram of Test Setup Test Standard Severity Levels and Performance Criterion EUT Configuration Operating Condition of EUT Test Procedure...20
4 6.7 Test Result INJECTED CURRENTS SUSCEPTIBILITY TEST Block Diagram of Test Setup Test Standard Severity Levels and Performance Criterion EUT Configuration Operating Condition of EUT Test Procedure Test Results VOLTAGE DIPS AND INTERRUPTIONS TEST Block Diagram of Test Setup Test Standard Severity Levels and Performance Criterion EUT Configuration Operating Condition of EUT Test Procedure Test Result...26 APPENDIX I (Photos of EUT) Page 4 of 32
5 1. GENERAL INFORMATION 1.1. Description of Device (EUT) EUT : Color Dome Camera Model : YCM-550, YCM-550C, SW-550, SW-560, SW-550C, SW-560C, SW-510, SW-510C, SW-30M, SW-100, SW-130, YCM-560, YCM-560C, YR-516, YCM-515, YCM-512, YC-807, YR-510, YR-510C, YR-520, YR-520C, YC-809, YC-807, YC-301, YR-801, YR-803, YCM-20, YCM-25, YCM-30, YCM-40, YCM-45, YCM-532, YCM-622, YCM-622C, YCM-501, YCM-502, YCM-513, YCM-513C, YCM-525, YR300, YR-600, YR-680, SW-600, SW-680 The applicant models are all identical in interior structure, electrical circuits and components, and just the model names are different for the marketing requirement. We prepare YCM-550 for EMC test. Power Supply of EUT : DC 12V / AC 24V Applicant : Shenzhen LSVT Co., Ltd. Address : 5th Floor, 2nd Block, Zhongyuntai Industrial Park, No. 1 Road, Tangtou, Shiyan Street, Bao an District, Shenzhen City Manufacturer : Shenzhen LSVT Co., Ltd. Address : 5th Floor, 2nd Block, Zhongyuntai Industrial Park, No. 1 Road, Tangtou, Shiyan Street, Bao an District, Shenzhen City Date of receiver : Nov. 17, 2010 Date of Test : Nov. 18, 2010 to Dec. 01, 2010 Page 5 of 32
6 1.2. Description of Support Device PC Monitor Mouse Keyboard Printer : Manufacturer: DELL M/N: E157FPc S/N: 53SM12X CCC,FCC,VCCI,GS,S,CE : Manufacturer: SAMSUNG M/N: 710MP [R]S S/N: MH17HVY500468F CCC,SA,UL : Manufacturer: DELL M/N: M056UOA S/N: F1101WOS CE, VCCI,FCC,GS,UL : Manufacturer: DELL M/N: SK-8135 S/N: CN-0DJ U6 VCCI,CE, FCC : Manufacturer: SAMSUNG M/N: ML-1610 S/N:BKAYB04125 CCC,CE,UL 1.3. Test Standards EN : 1995+A1: 1998+A2: 2003 Test Standards Alarm systems -- Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems / / / / / / 1.4. Measurement Uncertainty Radiation Uncertainty : Ur = ± 3.84dB Conduction Uncertainty : Uc = ± 2.72dB Page 6 of 32
7 2. MEASURING DEVICE AND TEST EQUIPMENT 2.1. For Power Line Conducted Emission Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCS /018 May 27, Year 2. L.I.S.N Rohde & Schwarz ESH2-Z /005 May 27, Year 3. 50ΩCoaxial Switch Anritsu MP59B M20531 N/A N/A 4. Pulse Limiter Rohde & Schwarz ESH3-Z May 27, Year 5. Voltage Probe Rohde & Schwarz TK9416 N/A May 27, Year 2.2. For Radiated Emission Measurement Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Spectrum Analyzer ANRITSU MS2661C May 27, Year 2. Test Receiver Rohde & ESCS /018 May 27, Year Schwarz 3. Bilog Antenna Schwarzbeck VULB May 27, Year Coaxial Switch Anritsu Corp MP59B May 27, Year 5. EMI Power Line Filter DUOJI EME FNF 201 B16 N/A May 27, Year 6. EMI Power Line Filter JIANLI DL-40C N/A May 27, Year 7. Cable Schwarzbeck AK9513 ACRX1 May 27, Year 8. Cable Rosenberger N/A FP2RX2 May 27, Year 9. Cable Schwarzbeck AK9513 CRPX1 May 27, Year 10. Cable Schwarzbeck AK9513 CRRX2 May 27, Year 11. Signal Generator HP 8648A 3625U00573 May 27, Year 2.3. For Harmonic Current / Flicker Measurement Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Power Frequency HAEFELY PHF May 27, Year Test System 2. PC N/A P2L97 N/A May 27, 2010 N/A 2.4. For Electrostatic Discharge Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. ESD Tester HAEFELY PESD1600 H May 27, Year Page 7 of 32
8 2.5. For RF Strength Susceptibility Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Signal Generator HP 8648A 3625U00573 May 27, Year 2. Amplifier AR 500A NCR NCR 3. Amplifier AR 100W/1000M NCR NCR 4. Isotropic Field AR FM NCR NCR Monitor 5. Isotropic Field Probe AR FP May 27, Year 6. Biconic Antenna EMCO NCR NCR 7. Log-periodic AR AT NCR NCR Antenna 8. PC N/A 486DX2 N/A N/A N/A 2.6. For Electrical Fast Transient /Burst Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Burst Tester HAEFELY PEFT May 27, Year 2. Coupling Clamp HAEFELY IP-4A May 27, Year 2.7. For Surge Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Surge Tester HAEFELY PSURGE May 27, Year 2.8. For Injected Current Susceptibility Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Simulator EMTEST CWS500C May 27, Year 2. CDN EMTEST CDN-M May 27, Year 3. CDN EMTEST CDN-M May 27, Year 4. Injection Clamp EMTEST F May 27, Year MM 5. Attenuator EMTEST ATT A May 27, Year 2.9. For Magnetic Field Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Magnetic Field HAEFELY MAG May 27, Year Tester Page 8 of 32
9 2.10. For Voltage Dips and Interruptions Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Dips Tester HAEFELY Pline May 27, Year Page 9 of 32
10 3. ELECTROSTATIC DISCHARGE IMMUNITY TEST 3.1 Block Diagram of Test Setup Block Diagram of the EUT and the simulators AC Mains Adapter A EUT (EUT: Color Dome Camera ) Block diagram of ESD test setup EUT ESD Tester 0.8 m AC Mains AC Mains (EUT: Color Dome Camera ) 3.2 Test Standard EN : 1995+A1: 1998+A2: 2003(EN : 2009 Severity Level: 3 / Air Discharge: ±8KV Level: 2 / Contact Discharge: ±4KV) 3.3 Severity Levels and Performance Criterion Severity level Level Test Voltage Contact Discharge (KV) Test Voltage Air Discharge (KV) 1. ±2 ±2 2. ±4 ±4 3. ±6 ±8 4. ±8 ±15 X Special Special Performance criterion: B Page 10 of 32
11 3.4 EUT Configuration The configuration of EUT is listed in Section Operating Condition of EUT Same as conducted emission measurement, which is listed in Section 3.4. Except the test set up replaced by Section Test Procedure Air Discharge: This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. Contact Discharge: All the procedure shall be same as Section except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. Indirect discharge for horizontal coupling plane At least 10 single discharges (in the most sensitive polarity) shall be applied at the front edge of each HCP opposite the center point of each unit (if applicable) of the EUT and 0.1m from the front of the EUT. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to its front edge during the discharge. Indirect discharge for vertical coupling plane At least 10 single discharge (in the most sensitive polarity) shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated. 3.7 Test Results PASS Please refer to the following page Page 11 of 32
12 Electrostatic Discharge Test Result SHENZHEN SETEK TECHNOLOGY CO.,LTD Applicant : Shenzhen LSVT Co., Ltd. Test Date : Nov. 29, 2010 EUT : Color Dome Camera Temperature : 22 M/N : YCM-550 Humidity : 50% Power Supply : DC 12V Test Mode : Normal Air discharge : ±8.0KV Criterion : B Contact discharge: ±6.0KV Location Test Engineer : Jack Kind A-Air Discharge C-Contact Discharge Result Gaps A PASS Metal C PASS HCP C PASS VCP of front C PASS VCP of rear C PASS VCP of left C PASS VCP of right C PASS Test Equipment: ESD Simulator (HAEFELY, PESD1600) Page 12 of 32
13 4. RF FIELD STRENGTH SUSCEPTIBILITY TEST 4.1 Block Diagram of Test i. Block diagram of connection between the EUT and Load AC Mains Adapter A EUT (EUT: Color Dome Camera ) ii. Block diagram of RS test setup 3 Meters EUT Anechoic Chamber 0.8 Meter Measurement Room Power Amp Signal Generator (EUT: Color Dome Camera ) 4.2 Test Standard EN : 1995+A1: 1998+A2: 2003(EN : 2006 (Severity Level: 2, 3V / m)) Page 13 of 32
14 4.3 Severity Levels and Performance Criterion iii. Severity Levels Level Field Strength V/m X Special iv. Performance Criterion : A 4.4 EUT Configuration on Test The configuration of the EUT is same as Section Operating Condition of EUT Same as radiated emission measurement which is listed in Section 3.4, except the test setup replaced as Section Test Procedure The EUT are placed on a table which is 0.8 meter high above the ground. The EUT is set 3 meters away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of the EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor its screen. All the scanning conditions are as following: Condition of Test Remark Fielded Strength 10V/m (Severity Level 3) 2. Radiated Signal Modulated 3. Scanning Frequency MHz 4. Sweep time of radiated Decade/s 5. Dwell Time 1 Sec. Test Results PASS. Please refer to the following page. Page 14 of 32
15 RF Field Strength Susceptibility Test Results SHENZHEN SETEK TECHNOLOGY CO., LTD. Applicant : Shenzhen LSVT Co., Ltd. Test Date : Nov. 29, 2010 EUT : Color Dome Camera Temperature : 22 M/N : YCM-550 Humidity : 50 % Field Strength : 10 V/m Criterion : A Power Supply : DC 12V Test Mode : Normal Test Engineer: Jack Frequency Range : 80 MHz to1000 MHz Modulation: None Pulse AM 1KHz 80% Frequency Rang 1: Frequency Rang 2: 80~ 2000MHz Steps 1 / % # / % Horizontal Vertical Horizontal Vertical Front PASS PASS Right PASS PASS Rear PASS PASS Left PASS PASS Test Equipment : 1. Signal Generator : 2031 (MARCONI) 2. Power Amplifier : 500A100 & 100W/1000M1 (A&R) 3. Power Antenna : 3108 (EMCO) & AT1080 (A&R) 4. Field Monitor : FM2000 (A&R) Note: Page 15 of 32
16 5. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 5.1 Block Diagram of Test Setup Block Diagram of the EUT AC Mains Adapter A EUT EFT Test Setup (EUT: Color Dome Camera ) AC Mains EUT EFT/B Tester 0.8 m AC Mains (EUT: Color Dome Camera ) 5.2 Test Standard EN : 1995+A1: 1998+A2: 2003(EN : 2004+A1:2010 Level 3: 2KV) 5.3 Severity Levels and Performance Criterion Severity level Open Circuit Output Test Voltage ±10% Level On Power Supply Lines On I/O (Input/Output) Signal data and control lines KV 0.25 KV 2. 1 KV 0.5 KV 3. 2 KV 1 KV 4. 4 KV 2 KV X Special Special Performance criterion : B 5.4 EUT Configuration The configuration of EUT is listed in Section 3.3. Page 16 of 32
17 5.5 Operating Condition of EUT Setup the EUT as shown in Section 9.1. Turn on the power of all equipments. Let the EUT work in test mode (Normal) and measure it. 5.6 Test Procedure The EUT is put on the table which is 0.8 meter high above the ground. This reference ground plane shall project beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. For input and output AC power ports: The EUT is connected to the power mains by using a coupling device which couples the EFT interference signal to AC power lines. Both polarities of the test voltage should be applied during compliance test and the duration of the test is 2 mins. For signal lines and control lines ports: No I/O ports. It s unnecessary to test. For DC output line ports: It s unnecessary to test. 5.7 Test Result PASS Please refer to the following page Page 17 of 32
18 Electrical Fast Transient/Burst Test Results SHENZHEN SETEK TECHNOLOGY CO., LTD Standard IEC EN Result : PASS / FAIL Applicant : Shenzhen LSVT Co., Ltd. EUT : Color Dome Camera M/N : YCM-550 Input Voltage: DC 12V Criterion : B Ambient Condition : 20 50% RH Operation Mode : Normal Line : AC Mains Line : Signal line DC line Coupling : Direct Coupling : Capacitive Test Time : 120s Line Test Voltage Result(+) Result(-) L 2KV PASS PASS N 2KV PASS PASS PE L N 2KV PASS PASS L PE N PE L N PE Signal line DC line Note: Test Equipment Burst Tester Model : PEFT 4010 Page 18 of 32
19 6. SURGE IMMUNITY TEST 6.1 Block Diagram of Test Setup Block Diagram of the EUT AC Mains Adapter A EUT (EUT: Color Dome Camera ) Surge Test Setup AC Mains EUT Surge Tester 0.8 m AC Mains (EUT: Color Dome Camera ) 6.2 Test Standard EN : 1995+A1: 1998+A2: 2003(EN : 2006) Severity Level: Line to Line: Level 2, 1.0KV 6.3 Severity Levels and Performance Criterion Severity level Performance criterion : B Severity Level * Open-Circuit Test Voltage KV Special Page 19 of 32
20 6.4 EUT Configuration The configuration of EUT is listed in Section Operating Condition of EUT Setup the EUT as shown in Section Turn on the power of all equipments. Let the EUT work in test mode (Normal) and measure it. 6.6 Test Procedure 1) Set up the EUT and test generator as shown on Section ) For line to line coupling mode, provide a 1.0 KV 1.2/50us voltage surge (at open-circuit condition) and 8/20us current surge to EUT selected points. 3) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are conducted during test. 4) Different phase angles are done individually. 5) Record the EUT operating situation during compliance test and decide the EUT immunity criterion for above each test. 6.7 Test Result PASS. Please refer to the following page. Page 20 of 32
21 Surge Immunity Test Result SHENZHEN SETEK TECHNOLOGY CO., LTD. Applicant : Shenzhen LSVT Co., Ltd. Test Date : Nov. 25, 2010 EUT : Color Dome Camera Temperature : 22 M/N : YCM-550 Humidity : 50% Power Supply : DC 12V Test Mode : Normal Test Engineer : Jack Criterion : B Location Polarity Phase Number of Pulse Voltage (KV) Result Angle Pulse L1-L2 + 0 o 5 1 PASS + 90 o 5 1 PASS o 5 1 PASS o 5 1 PASS - 0 o 5 1 PASS - 90 o 5 1 PASS o 5 1 PASS o 5 1 PASS L-PE 90 N-PE Signal line Remark: Test Equipment : Surge Tester Psurge4.1 Page 21 of 32
22 7. INJECTED CURRENTS SUSCEPTIBILITY TEST 7.1 Block Diagram of Test Setup Block Diagram of the EUT AC Mains Adapter A EUT Block Diagram of Test Setup 0.1 m (EUT: Color Dome Camera ) EUT CDN Ground Reference Support AC Mains Signal Power Generator Amplifier (EUT: Color Dome Camera ) 7.2 Test Standard EN : 1995+A1: 1998+A2: 2003 (EN : 2009, Severity Level: Level 3, 10V (rms), (0.15MHz ~ 80MHz) 7.3 Severity Levels and Performance Criterion Severity level Level Performance criterion: A Field Strength V X Special Page 22 of 32
23 7.4 EUT Configuration The configuration of EUT is listed in Section Operating Condition of EUT Setup the EUT as shown in Section Turn on the power of all equipments. Let the EUT work in test mode (Normal) and measure it. 7.6 Test Procedure 1) Set up the EUT, CDN and test generators as shown on Section ) Let the EUT work in test mode and measure it. 3) The EUT are placed on an insulating support 0.1m high above a ground reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). 4) The disturbance signal described below is injected to EUT through CDN. 5) The EUT operates within its operational mode(s) under intended climatic conditions after power on. 6) The frequency range is swept from 150KHz to80mhz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1KHz sine wave. 7) The rate of sweep shall not exceed 1.5*10-3 decades/s. Where the frequency is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value. 8) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion. 7.7 Test Results PASS. Please refer to the following page. Page 23 of 32
24 Injected Currents Susceptibility Test Results SHENZHEN SETEK TECHNOLOGY CO., LTD. Applicant : Shenzhen LSVT Co., Ltd. Test Date: Nov. 25, 2010 EUT : Color Dome Camera Temperature : 22 M/N : YCM-550 Humidity : 58% Power Supply : DC 12V Test Engineer : Jack Test Mode : Normal Frequency Range Injected Position Strength Criterion Result (MHz) (Unmodulated) 0.15 ~ 80 AC Mains 10V A PASS Test Mode : Frequency Range (MHz) Injected Position Strength (Unmodulated) Criterion Result Remark : 1. Modulation Signal:1KHz 80% AM Measurement Equipment : Simulator: CWS 500 (SWITZERLAND EMTEST) CDN : CDN-M2 (SWITZERLAND EMTEST) CDN-M3 (SWITZERLAND EMTEST) EM CLAMP(LÜTHI) Note: Page 24 of 32
25 8. VOLTAGE DIPS AND INTERRUPTIONS TEST 8.1 Block Diagram of Test Setup Block Diagram of the EUT AC Mains Adapter A EUT Dips Test Setup (EUT: Color Dome Camera ) AC Mains EUT Dips Tester 0.8 m AC Mains (EUT: Color Dome Camera ) 8.2 Test Standard EN : 1995+A1: 1998+A2: 2003(EN : 2004) Page 25 of 32
26 8.3 Severity Levels and Performance Criterion Severity level Test Level %UT Voltage dip and short interruptions %UT Duration (in period) Performance criterion : B&C 8.4 EUT Configuration The configuration of EUT is listed in Section Operating Condition of EUT Setup the EUT as shown in Section Turn on the power of all equipments. Let the EUT work in test mode (Normal) and measure it. 8.6 Test Procedure 1) Set up the EUT and test generator as shown on Section ) The interruptions is introduced at selected phase angles with specified duration. 3) Record any degradation of performance. 8.7 Test Result PASS. Please refer to the following page. Page 26 of 32
27 Voltage Dips And Interruptions Test Results Applicant : Shenzhen LSVT Co., Ltd. EUT : Color Dome Camera Temperature : 22 M/N : YCM-550 Humidity : 58% Power Supply : AC 230V Test Mode : Normal Test Level Voltage Dips & Short Interruptions % U T % U T Duration (in period) Criterion A B C D Result ;1;5 and 10P B PASS ;1;5 and 10P C PASS ;1and 5 P B PASS Remark: U T is the rated voltage for the equipment. Test Equipment : Dips Tester PLI LP Page 27 of 32
28 APPENDIX I (Photos of EUT) Page 28 of 32
29 Page 29 of 32
30 Page 30 of 32
31 Page 31 of 32
32 THE END Page 32 of 32
SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT
Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry
More informationEMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20
EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan
More informationEMC TEST REPORT For. Webcam. Model Number: CAM67U
EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology
More informationRated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
More informationTest Report. Prepared for: Technologic Systems, Inc. Model: TS-8820
Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)
More informationEN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5
EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA
More informationTEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationStandard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationTest Report #: 1981-3 Date: April 8, 2005
Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationMYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2
MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART
More informationElectromagnetic Compatibility Test Report Test results of Floww equipment
Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww
More informationPrepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.
www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives
More informationVariant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.
EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of
More informationTEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio
TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationCE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.
EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian
More informationEMC Test for Compliance with EU EMC Directive 2004/108/EU
EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods
More informationFCC PART 15B CLASS A MEASUREMENT AND TEST REPORT
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original
More informationEMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E
Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :
More informationELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010
ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......
More informationCERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)
CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationMeasurement of RF Emissions from a Final Coat Electronics Corrosion Module
Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA
More informationDual Chamber Temporary External Pacemaker
5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes
More informationAN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x
TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide
More informationTEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.
198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: sgs_internet_operations@sgs.com
More informationClamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise
TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic
More informationBioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date
Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT
More informationTEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement
TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More information15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:
More informationLAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps
More informationNMI M 6-2 Electricity Meters. Part 2: Test Report Format
NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,
More informationNMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)
Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIM R 118:1995(E), NEQ) The English version of international standard OIM R 118:1995 Testing Procedures
More informationEMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More information30 In Compliance October 2014 www.incompliancemag.com
30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,
More informationQFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationSTRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationEvaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers
More informationTest result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18
Report No: FCC 1106180 File reference No: 2011-07-18 ISO/IEC17025Accredited Lab. Applicant: FUJIAN NAN AN BAOFENG ELECTRONICS CO., LTD Product: Model No: Trademark: Two Way Radio UV-3R BAOFENG Test Standards:
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More informationEspotel Test Laboratory Services. November 20, 2014
Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Partial Test of: BTM411 To: EN 300 328 V1.7.1 (2006-10) Test Report Serial No: RFI/RPT1/RP76018JD01A This Test Report Is Issued Under The Authority Of Brian Watson, Operations
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationMYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING
TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationMSAN-001 X-Band Microwave Motion Sensor Module Application Note
1. Introduction HB Series of microwave motion sensor module are X-Band Mono-static DRO Doppler transceiver front-end module. These modules are designed for movement detection, like intruder alarms, occupancy
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationRX-AM4SF Receiver. Pin-out. Connections
RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationCE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board
CE EMC Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board : Texas Instruments : WL1835MODCOM8B STANDARD : ETSI EN 301 489-1 V1.9.2
More informationHCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
More informationCoupling/Decoupling Networks (CDN)
Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and
More informationElectromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613
Report No.: 0000091428 31160742.001 Page 1 of 36 Electromagnetic Compatibility Test Report Prepared in accordance with EN 55022: 2006, +A1: 2007 On DC DC umodule Regulator LTM4613 For Linear Technology
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationFCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT
FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More informationDATA SHEET DVI - HDCP Extension Cable
DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationCoupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC 61000-4 - 6 and CISPR 15 / CISPR 22 IEC 61000-4 - 6
Coupling- / Decoupling Network 150 khz 300 MHz IEC 61000-4 - 6 and CISPR 15 / CISPR 22 150 khz 230 MHz IEC 61000-4 - 6 10 khz 230 MHz IEC 61000-4 - 6 and IEC 61326-3 - 2 and NAMUR Coupling and decoupling
More informationAmplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)
Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) 1. Description and Specifications Contents 1.1 Description 1.2 1.2 Specifications 1.3 1.3 Tested parameters in production
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationR&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz
Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line
More informationFoxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
More informationRules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition
More informationBroadband over Power Line (BPL) Test Procedures and Equipment Authorization
Broadband over Power Line (BPL) Test Procedures and Equipment Authorization Andy Leimer Equipment Authorization Branch Federal Communications Commission Office of Engineering and Technology Laboratory
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationVerizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012
Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision
More informationRAPPORTO DI PROVA TEST REPORT. Titolo (Title): EMC Immunity test and measure of the harmonic components and Flicker on. SP40 plus
RAPPORTO DI PROVA TEST REPORT Titolo (Title): EMC Immunity test and measure of the harmonic components and Flicker on SP40 plus Richiedente (Customer): - Ente/Società (Dept./Firm): Compuprint S.p.A. -
More informationPredicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations.
Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. D. A. Weston RE02Tx.rep 14-6-2004 NARTE Certified EMC
More informationReport No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894
Test Report Product Name All in one PC Model No. Transmitter Module. MSI / MS-6894 MS-6633, VS12489, NetOn AP1900 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,
More informationAgilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
More informationCurrent Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
More informationAgilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
More informationPE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface
More informationHuawei NE5000E 400Gbps Flexible Line Processing Unit
Huawei NE5000E 400Gbps Flexible Line Processing Unit Huawei NE5000E 400Gbps Flexible Line Processing Unit Overview The Huawei NetEngine5000E router (NE5000E) is a high-end IP core network router. It is
More informationAN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz
AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2
More informationAN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output
Evaluation of Anechoic Chambers For EMC Measurements Using A CNE Overview Anechoic chambers are used for EMC testing primarily for radiated emissions (RE) and radiated immunity (RI) in the frequency range
More informationORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationR&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6
More informationEMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.
EMC for test engineers by An introduction to the world of EMC compliance testing for engineers new to the topic. Index: Introduction Page 3 The EU Directive Page 3 The EMC Standards. Page 3 Compliance
More informationAXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
More information