1 PVC INSULATED CABLES Need Power Connections? We Have The Solutions!

2 TABLE DESCRIPTION SPECIFICATION 1 SingleCore 0/0V PVCInsulated, NonSheathed MS 13 / BS 00 / General Purpose Cables IEC A SINGLECORE /00V UNARMOURED CABLES with CIRCULAR MS 13 / BS 00 / Copper s IEC B SingleCore 00/00V Unarmoured Cables with Circular MS 2 / BS 3 / Copper s IEC C SingleCore 00/00V Armoured Cables with Circular MS 2 / BS 3 / Copper s IEC A TwoCore /00V Unarmoured Cables with Circular MS 13 / BS 00 / Copper s IEC B TwoCore 00/00v Unarmoured Cables with Circular MS 2 / BS 3 / Copper s IEC C TwoCore 00/00C Armoured Cables with Circular MS 2 / BS 3 / Copper s IEC 0021 A ThreeCore /00V Unarmoured Cables with Circular MS 13 / BS 00 / Copper s IEC 0021 B ThreeCore 00/00V Unarmoured Cables with Circular MS 2 / BS 3 / Copper s IEC 0021 C ThreeCore 00/00v Armoured Cables with Circular MS 2 / BS 3 / Copper s IEC 0021 A FourCore /00V Unarmoured Cables with Circular MS 13 / BS 00 / Copper s IEC 0021 B FourCore 00/00V Unarmoured Cables with Circular MS 2 / BS 3 / Copper s IEC 0021 C FourCore 00/00V Armoured Cables with Circular MS 2 / BS 3 / Copper s IEC 0021 A MultiCore 00/00V Auxiliary Cables with Solid MS 2 / BS 3 / Copper s IEC 0021 B MultiCore 00/00V Auxiliary Cables with Stranded MS 2 / BS 3 / Copper s IEC 0021 A B C D E F Sustained Current Rating And Voltage Drop For SingleCore PvcInsulated Cables with Copper s Sustained Current Rating And Voltage Drop For Twocore PvcInsulated Cables with Copper s Sustained Current Rating And Voltage Drop For Threecore And FourCore PVCinsulated Cables with Copper s Sustained Current Rating And Voltage Drop For Auxiliary/ MultiCore PVCInsulated Cables with Copper s Electrical Characteristics Of PVCInsulated Cables with Copper s Minimum Installation Radius Of PVCInsulated Cables with Copper s

3 PVC INSULATED CABLES LOW VOLTAGE SINGLECORE PVCINSULATED POWER CABLES BASIC CONSTRUCTION PLAIN ANNEALED COPPER SHAPE ROUND CIRCULAR STRANDED OR COMPACTED CIRCULAR STRANDED INSULATION Colours PVC Red, Black, Yellow, Blue, Green, White ang Grey MS 13 BS 00 IEC 0021 LOW VOLTAGE SINGLE CORE PVCINSULATED POWER CABLES TABLE 1 SINGLECORE 0/0V PVC INSULATED, NONSHEATHED GENERAL PURPOSE CABLES sq No./ 1/1.38 /0.3 1/8 /0. / / /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ 1/ 1/ / Resistance at 0 C

4 LOW VOLTAGE SINGLECORE PVCINSULATED POWER CABLES UNARMOURED CABLES Sheath ARMOURED CABLES Bedding Armour Wire Outersheath BASIC CONSTRUCTION PLAIN ANNEALED COPPER SHAPE ROUND CIRCULAR STRANDED OR COMPACTED CIRCULAR STRANDED INSULATION PVC BEDDING PVC ARMOUR WIRE ALUMINIUM WIRES SHEATH MATERIAL PVC

5 MS 13 BS 00 IEC 0021 LOW VOLTAGE SINGLE CORE PVCINSULATED POWER CABLES TABLE 2A SINGLECORE /00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq No./ 1/1.38 /0.3 1/8 /0. / / /1.3 /0 19/1.3 19/1.3 MS 2 BS 3 IEC Resistance at 0 C LOW VOLTAGE SINGLE CORE PVCINSULATED POWER CABLES TABLE 2B SINGLECORE 00/00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq No./ 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ 1/ 1/ / 12/ 12/3.20 MS 2 BS 3 IEC Colours for core identification : red or black Black or white sheath LOW VOLTAGE SINGLE CORE PVCINSULATED POWER CABLES TABLE 2C SINGLECORE 00/00V ARMOURED CABLES WITH CIRCULAR COPPER S sq No./ 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ 1/ 1/ / 12/ 12/ ** of Bedding Nominal armour wire diameter Colours for core identification : red or black Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately ) need not be checked by measurement. 8

6 00/00V TWOCORE PVCINSULATED POWER CABLES UNARMOURED CABLES Filler Core Wrapping Outersheath ARMOURED CABLES Filler Core Wrapping Bedding Armour Wire Outersheath BASIC CONSTRUCTION COPPER OR ALUMINIUM SHAPE CIRCULAR STRANDED OR COMPACTED CIRCULAR STRANDED INSULATION BEDDING ARMOUR SHEATH MATERIAL PVC PVC GALVANISED STEEL WIRES PVC 9

7 MS 13 BS 00 IEC 0021 LOW VOLTAGE TWO CORE PVCINSULATED POWER CABLES TABLE 3A TWOCORE /00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq No./ 1/1.38 /0.3 1/8 /0. / / / Resistance at 0 C MS 2 BS 3 IEC 0021 LOW VOLTAGE TWO CORE PVCINSULATED POWER CABLES TABLE 3B TWOCORE 00/00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq No./ /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ MS 2 BS 3 IEC Colours for core identification : red and black Black sheath LOW VOLTAGE TWO CORE PVCINSULATED POWER CABLES TABLE 3C TWOCORE 00/00V ARMOURED CABLES WITH CIRCULAR COPPER S sq No./ /0.3 /0. / / /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ ** of bedding Nominal armour wire diameter Colours for core identification : red and black Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately ) need not be checked by measurement. 0

8 00/00V THREECORE PVCINSULATED POWER CABLES UNARMOURED CABLES Filler Core Wrapping Outersheath ARMOURED CABLES Filler Core Wrapping Bedding Armour Wire Outersheath BASIC CONSTRUCTION MATERIAL COPPER OR ALUMINIUM SHAPE CIRCULAR STRANDED OR COMPACTED CIRCULAR STRANDED INSULATION PVC BEDDING PVC ARMOUR GALVANISED STEEL WIRES SHEATH MATERIAL PVC 1

9 MS 13 BS 00 IEC 0021 LOW VOLTAGE THREE CORE PVCINSULATED POWER CABLES TABLE A THREECORE /00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq No./ 1/1.38 /0.3 1/8 /0. / / / Resistance at 0 C MS 2 BS 3 IEC 0021 LOW VOLTAGE THREE CORE PVCINSULATED POWER CABLES TABLE B THREECORE 00/00V UNARMOURED CABLES WITH CIRCULAR COPPER CONDUC sq No./ /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ MS 2 BS 3 IEC Colours for core identification : red, yellow and blue Black sheath LOW VOLTAGE THREE CORE PVCINSULATED POWER CABLES TABLE C THREECORE 00/00V ARMOURED CABLES WITH CIRCULAR COPPER S sq No./ /0.3 /0. / / /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ ** of bedding Nominal armour wire diameter Colours for core identification : red, yellow and blue Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately ) need not be checked by measurement. 2

10 00/00V FOURCORE PVCINSULATED POWER CABLES UNARMOURED CABLES Filler Core Wrapping Outersheath ARMOURED CABLES Filler Core Wrapping Bedding Armour Wire Outersheath BASIC CONSTRUCTION MATERIAL COPPER OR ALUMINIUM SHAPE CIRCULAR STRANDED OR COMPACTED CIRCULAR STRANDED INSULATION PVC BEDDING PVC ARMOUR GALVANISED STEEL WIRES SHEATH MATERIAL PVC 3

11 MS 13 BS 00 IEC 0021 LOW VOLTAGE FOUR CORE PVCINSULATED POWER CABLES TABLE A FOURCORE /00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq. No./ 1. 1/ / /8 2. /0. / / / Approx Resistance at 0 C MS 2 BS 3 IEC 0021 LOW VOLTAGE FOUR CORE PVCINSULATED POWER CABLES TABLE B FOURCORE 00/00V UNARMOURED CABLES WITH CIRCULAR COPPER S sq No./ /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ MS 2 BS 3 IEC Approx Colours for core identification : red, yellow and blue Black sheath LOW VOLTAGE FOUR CORE PVCINSULATED POWER CABLES TABLE C FOURCORE 00/00V ARMOURED CABLES WITH CIRCULAR COPPER S sq No./ /0.3 /0. / / /1.3 /0 19/1.3 19/1.3 19/8 19/ 3/8 3/3 3/ 3/ 1/ 1/ ** of bedding Nominal armour wire diameter Colours for core identification : red, yellow, blue and black Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately ) need not be checked by measurement.

12 MS 2 BS 3 IEC 0021 LOW VOLTAGE MULTI CORE PVCINSULATED POWER CABLES TABLE A MULTICORE 00/00V AUXILIARY CABLES WITH SOLID COPPER S No of cores sq No./ 1/1.38 1/ ** of bedding Nominal armour wire diameter MS 2 BS 3 IEC 0021 LOW VOLTAGE MULTI CORE PVCINSULATED POWER CABLES TABLE B MULTICORE 00/00V AUXILIARY CABLES WITH SOLID COPPER S No of cores sq No./ /0.3 /0. / ** of bedding Nominal armour wire diameter Colours for core identification : white insulation with printed black numbering Black sheath **In case of TAPED BEDDING: The thickness of taped bedding (approximately ) need not be checked by measurement.

13 MS 13/MS 2 BS 00/BS 3 IEC 0021 SUSTAINED CURRENT RATING AND VOLTAGE DROP TABLE A SUSTAINED CURRENT RATING AND VOLTAGE DROP FOR SINGLECORE PVC INSULATED CABLES WITH COPPER S sq Trefoil *Installed vertically spaced Unarmoured Cables Current Rating In Air In Ground Spaced* Trefoil Spaced* Voltage Drop Trefoil Spaced* Trefoil Armoured Cables Current Rating In Air In Ground Spaced* Trefoil Spaced* Voltage Drop Trefoil Spaced* MS 13/MS 2 BS 00/BS 3 IEC 0021 SUSTAINED CURRENT RATING AND VOLTAGE DROP TABLE B SUSTAINED CURRENT RATING AND VOLTAGE DROP FOR TWOCORE PVC INSULATED CABLES WITH COPPER S Unarmoured Cables Armoured Cables Current Rating Current Rating Voltage Drop In Air In Ground In Air In Ground Voltage Drop sq

14 MS 13/MS 2 BS 00/BS 3 IEC 0021 SUSTAINED CURRENT RATING AND VOLTAGE DROP TABLE C SUSTAINED CURRENT RATING AND VOLTAGE DROP FOR THREECORE AND FOURCORE PVC INSULATED CABLES WITH COPPER S Unarmoured Cables Armoured Cables Current Rating Current Rating Voltage Drop In Air In Ground In Air In Ground Voltage Drop sq MS 13/MS 2 BS 00/BS 3 IEC 0021 SUSTAINED CURRENT RATING AND VOLTAGE DROP TABLE D SUSTAINED CURRENT RATING AND VOLTAGE DROP FOR AUXILIARY/MULTICORE PVC INSULATED CABLES WITH COPPER S Twin Cable Single Phase AC or DC Three or Four Cable Three Phase AC or DC Current Rating Current Rating Voltage Drop In Air In Ground In Air In Ground Voltage Drop sq RATING FACTOR FOR OTHER TEMPERATURES Cables in air Temperature C Factor Cables in ground Temperature C Factor 0 0 0

15 MS 13/MS 2 BS 00/BS 3 IEC 0021 ELECTRICAL CHARACTERISTICS TABLE E PVC INSULATED CABLES WITH COPPER S sq AC Resistance at 0 C Not applicable to unarmoured cables Armoured Cables Single Core Reactance at 0Hz Trefoil Flat Capacitance μf/km Armoured or Unarmoured Auxiliary/Multicore Cables AC Resistance at 0 C Reactance at 0Hz Two core μf/km Armoured Cables Capacitance Three core μf/km Four core μf/km MS 13/MS 2 BS 00/BS 3 IEC 0021 MINIMUM INSTALLATION RADIUS TABLE F PVC INSULATED CABLES WITH COPPER S TYPE OF AND CABLE* OVERALL DIAMETER, D MINIMUM INTERNAL RADIUS OF BEND CIRCULAR COPPER S, < 3D UNARMOURED > D < 2 D > 2 D CIRCULAR COPPER S, ARMOURED ANY D SHAPED COPPER S, ARMOURED OR UNARMOURED ANY 8D *Armoured or Unarmoured 8

16 9

Power and Wiring Cables

Power and Wiring Cables 1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC

More information

CONFLEX ELECTRIC CABLE

CONFLEX ELECTRIC CABLE CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard

More information

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying

More information

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase

More information

Cables, Cable Laying & Accessories Manual

Cables, Cable Laying & Accessories Manual Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version

More information

CURRENT RATINGS MORE THAN A CABLE

CURRENT RATINGS MORE THAN A CABLE CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:

More information

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35 CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv

More information

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum

More information

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the

More information

EDS 02-0027 11KV TRIPLEX CABLE

EDS 02-0027 11KV TRIPLEX CABLE THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:

More information

MICROCABLES. A complete vision of your connectivity needs. Catalogue

MICROCABLES. A complete vision of your connectivity needs. Catalogue MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

MEDIUM VOLTAGE CABLES Up to and including 36 KV

MEDIUM VOLTAGE CABLES Up to and including 36 KV MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

LOW VOLTAGE POWER CABLES

LOW VOLTAGE POWER CABLES LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED

More information

Fire Resistant Cables

Fire Resistant Cables 109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data

More information

MEDIUM VOLTAGE POWER CABLES

MEDIUM VOLTAGE POWER CABLES MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM

More information

PVC Insulated Mains Cable

PVC Insulated Mains Cable Series - 3182Y 2 Core Plain Annealed Copper Wire, PVC Insulation, PVC Sheath Insulation \ Sheath material : PVC : Blue, Brown Voltage : 300/500V 3182Y-0.5 0.5mm 2 16/0.2mm 2.2mm 6.2mm 62mm 39Ω/km 3A 3182Y-0.75

More information

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness 450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

6 ELECTRICAL PARAMETERS

6 ELECTRICAL PARAMETERS 6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com

More information

High Voltage Systems. Today. The history of cables

High Voltage Systems. Today. The history of cables High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Specializing in the cable business for over 38 years, PT. SUPREME CABLE Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international

More information

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69 Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

LT/HT Power & Control Cables

LT/HT Power & Control Cables LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of

More information

MV CABLE TYPE C 33-226

MV CABLE TYPE C 33-226 MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation

More information

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for

More information

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature

More information

Important Information: Complete Terms and Conditions are printed on sales invoices

Important Information: Complete Terms and Conditions are printed on sales invoices Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install

More information

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING

More information

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2

More information

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters 8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara 390 007 TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GETCO/E/TS PCBL025/RO DT.07-03-2008

More information

Building Cables and Wires

Building Cables and Wires Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for

More information

Outside Telephone Cable

Outside Telephone Cable Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH

TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor

More information

XLPE Land Cable Systems User s Guide. Rev 5

XLPE Land Cable Systems User s Guide. Rev 5 XLPE Land Cable Systems User s Guide Rev 5 CONTENT XLPE Land Cable Systems Introduction... 3 Design, installation and testing... 4 XLPE cables... 4 Cable accessories... 4 Installation of XLPE cable systems...

More information

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY

More information

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO. SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.

More information

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to

More information

ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008

ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,

More information

Technical cable guide

Technical cable guide Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now

More information

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

Removal of EP 20 10 00 02 SP High Voltage Cable

Removal of EP 20 10 00 02 SP High Voltage Cable TN 018: 2014 Technical Note For queries regarding this document standards@asa.transport.nsw.gov.au www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:

More information

COAX Cables Radio Frequency Cables

COAX Cables Radio Frequency Cables COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60227-1 Edition 2.2 1998-03 Edition 2:1993 consolidated with amendments 1:1995 and 2:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V

More information

International Electrotechnical Commission Standards

International Electrotechnical Commission Standards International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354

More information

LT/HT Power & Control Cables

LT/HT Power & Control Cables LT/HT Power & Control Cables Price List w.e.f. July, 2013 HT Single Core Power Cables HT Three Core Power Cables LT Aluminium Power Cables LT Copper Cables - Power and Control ISO-9001/ 14001/18001 Certified

More information

5.2. Overview. The better method to install solderless compression connectors on power cable

5.2. Overview. The better method to install solderless compression connectors on power cable 5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree

More information

LT/HT Power & Control Cables

LT/HT Power & Control Cables LT/HT Power & Control Cables Price List w.e.f. July, 2014 HT Single Core Power Cables HT Three Core Power Cables LT Aluminium Power Cables LT Copper Cables - Power and Control ISO-9001/ 14001/18001 Certified

More information

Flexible Control Cables

Flexible Control Cables Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport

More information

LT/HT Power & Control Cables

LT/HT Power & Control Cables LT/HT Power & Control Cables Price List w.e.f. July, 1 (Rev. 01) HT Single Core Power Cables HT Three Core Power Cables LT Aluminium Power Cables LT Copper Cables - Power and Control ISO-9001/ 1001/18001

More information

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009 RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical

More information

Screened cable and data cable segregation

Screened cable and data cable segregation December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

OPTICAL FIBER CABLES

OPTICAL FIBER CABLES OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL

More information

APPLICATION ORIENTED DESIGN OF CABLES

APPLICATION ORIENTED DESIGN OF CABLES APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

CAVEL VS80205 MADE IN ITALY 1000 V

CAVEL VS80205 MADE IN ITALY 1000 V 0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,

More information

Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications

Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications Power Cable Product descriptions and characteristics shown in this content have no legal effect. Nexans China has the right to change product specifications without prior notice. Any unauthorized dissemination,

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32 Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud

More information

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables 6-36kV Medium Voltage Underground Power Cables XLPE insulated cables Cable solutions to ensure the reliability of your energy network 2 With energy as the basis of its development, Nexans, the worldwide

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers

More information

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL

More information

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376

Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC

More information

MacArtney Underwater Cables - In stock

MacArtney Underwater Cables - In stock MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360

More information

CONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6

CONTENT. Robot cables. page. < The company... 3. < W - worldwide... 4. < Certifications... 5. < Clientele / supplier numbers... 6 CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

High Voltage Cable Systems

High Voltage Cable Systems High Voltage Cable Systems Cables and Accessories up to 550 kv Completing the picture nkt cables part of a world, counting on reliable and available electrical power Today a world without electrical power

More information

Fire retardant IEC 60332-1

Fire retardant IEC 60332-1 300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting

More information

108-93018 05 APR 2016 Rev M

108-93018 05 APR 2016 Rev M Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The

More information

Connect. Cable preparation and cutting tools

Connect. Cable preparation and cutting tools Connect Cable preparation and cutting tools 390 Our range of cable preparation tools includes hand-operated & ratchet action cable cutting tools, wire preparation & stripping tools and SWA & hydraulic

More information

100% EMI Emission Containment

100% EMI Emission Containment 100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive

More information

ROLLING STOCK CABLES

ROLLING STOCK CABLES CABLES UNIPOLAIRES EXTRA-SOUPLE SANS GAINE UNSHEATHED SINGLE CORE CABLES WITH EXTRA-FLEXIBLE CONDUCTOR CARACTERISTIQUES DU CABLE CABLE CHARACTERISTICS - 40 C Bon Résistant à Bon / Good Tenue au feu Zero

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building

More information

chapter6 Basic electrical circuitry and applications Unit 2 Outcome 3

chapter6 Basic electrical circuitry and applications Unit 2 Outcome 3 Basic electrical circuitry and applications chapter6 Unit 2 Outcome 3 The primary role of an electrician is the installation of electrical circuits and applications. In order to install any type of application,

More information