1 Fire Alarm Panel (Conventional) CONVENTIONAL FIRE ALARM SYSTEM a. 2, 4,8 to 16 zones b. Minimum 20 detectors per zone c. Compatibility with virtually all known conventional, ionization, optical & heat detector range d. LCD & LED indication for open, short, sounder fault, power supply fault, battery low etc. e. Fault buzzer mute facility f. Potential free contacts for both fire and fault g. Space for SMF batteries h. Connectivity with auto dialer (PSTN/GSM) as well with CMS i. Auxiliary relay contacts j. Walk test facility k. Compliance to IS 2189:1999 and approved by UL/LPCB/ERTL Certifications Required: UL/LPCB/ERTL. Make: Ravel. System Sensor, Jay, Bentel. Ionisation Smoke Detector(Conventional) a. Adjustable/programmable sensitivity b. Bi- colour LED light for status monitoring c. Operating voltage 8 to 33 VDC d. Flashing LED e. Magnetic test switch f. Addressable feature g. Response time 52 ms h. Sensitivity as per EN i. Low voltage operated Certifications Required: UL/LPCB approved Make: Apollo. System Sensor,. Optical Smoke Detector(Conventional) a. Adjustable/programmable sensitivity b. Bi- colour LED light for status monitoring c. Operating voltage 8 to 33 VDC d. Flashing LED e. Magnetic test switch f. Addressable feature g. Response time 52 ms h. Sensitivity as per EN i. Low voltage operated Certifications Required: UL/LPCB approved. Approve Make: Apollo. System Sensor,
2 Heat Detector (Conventional) a. Flashing LED b. Rate of rise cum fixed temperature c. Bi colour LED detector status indicator d. Programmable sensitivity through detector also e. Magnetic test switch f. Advance maintenance feature via remote hand held test unit g. UL/LPCB/EN approved h. Application temp. Range- -30 degree Celsius to +70 degree celcius Certifications Required: UL/LPCB approved Approve Make: Apollo. System Sensor,. Flame Detector (conventional) a. Using excellent UV sensor b. High sensitivity, reliable performance, dust proof, damp proofand corrosion proof c. Maximum response distance 25 m away from fire source d. Prolonged ambient temp. above 60 degree Celsius Certifications Required: UL/LPCB approved Make: Apollo. System Sensor, GST. Manual Call point(conventional) a. Anti- tamper facility b. Unique plug & play installation concept c. Backward compatibility d. Total flexi-ability in the choice of operating element e. Enhanced aesthetics f. Two part plug-in construction with base mounted termination allows easy installation and connection Certifications Required: ERTL Approved
3 SEMI ADDRESSABLE FIRE ALARM SYSTEM Fire Alarm Panel (Semi Addressable) a. 02, 04, 08 zone fire panel b. Digital display address of each device c. Maximum 32 device in each zone d. Minimum 50 event history with print facility e. Programmable through Keypad only f. Provision of separate Relay output for Fire and Panel fault g. Connectivity with auto dialer h. Compatible with all type & make of smoke detectors, heat detectors, flame detectors and manual call point i. Walk test j. Compatibility with CMS Certifications Required: UL/LPCB/ERTL. Make: Ravel. System Sensor, Jay, Bentel. Optical Smoke Detector(Semi Addressable) j. Adjustable/programmable sensitivity k. Bi- colour LED light for status monitoring l. Operating voltage 8 to 33 VDC m. Flashing LED n. Magnetic test switch o. Addressable feature p. Response time 52 ms q. Sensitivity as per EN r. Low voltage operated Certifications Required: UL/LPCB approved. Approve Make: Apollo. System Sensor,. Heat Detector (Semi Addressable) i. Flashing LED j. Rate of rise cum fixed temperature k. Bi colour LED detector status indicator l. Programmable sensitivity through detector also m. Magnetic test switch n. Advance maintenance feature via remote hand held test unit o. Application temp. Range- -30 degree Celsius to +70 degree celcius Approve Make: Apollo. System Sensor,.
4 Manual Call point (Semi Addressable) g. Anti- tamper facility h. Unique plug & play installation concept i. Backward compatibility j. Total flexi-ability in the choice of operating element k. Enhanced aesthetics l. Two part plug-in construction with base mounted termination allows easy installation and connection Make: Apollo. System Sensor. Hand Held Remote Device Tester a. To check optical detector physically b. To check the system health c. To reduce & increase the sensitivity of detector d. Operate from Minimum 10 feet distance Make: Apollo. System Sensor,. Fire Hooter (Semi addressable & Conventional) a. High sound output, low current consumption b. 02 tone sounder c. High Reliability and stable performance Make: Apollo. System Sensor,.
5 ADDRESSABLE FIRE ALARM SYSTEM Fire Alarm Panel (Addressable) a. Intelligent addressable panel of loop 1,2,3,..6 micro- processor expandable up to 300 loop based 02 wire fault tolerant loop for closed loop b. Each loop having maximum 99 detectors and 99 modules networking capacity c. Supervise & monitor all intelligent addressable detector and modules to the system for normal, trouble and alarm condition d. Compatible with Public addressable system e. All device manufactured supported f. Provision for signal silence switch, drill switch, system reset switch, lamp test, scroll display keys and print screen in panels g. Minimum 1000 history event with optional, local or remote print facility h. Minimum 20 zones with individual LED indicator. i. Panel programming facility both by computer and keypad j. Give location of all fire/fault conditions of addressable unit via the address code. k. Panel shall have rectifier, loop cards, minimum 80 character LCD unit to indicate fire/fault signal with address and analog output l. In built power supply and battery charger along with SMF batteries of 7 AH, 2x12 volt with 24 hour running back up. m. Minimum three 03 relay output for fire/fault/supervisory Addressable Smoke Detector (Addressable) a. Intelligent analog addressable inbuilt isolator photoelectric (light scattering) type with dual LED b. Hard addressable having rotary decade address switches from or soft addressable facility through computer also c. Provision for bifurcation of dust and smoke for rejection of false fire alarm d. Adjustable sensitivity through Detector e. Bi- colour LED light for status monitoring f. Detectors ceiling mount and shall include a separate twist-lock base which includes a tamper proof feature g. In built short circuit isolator
6 Addressable Heat Detector (Addressable) a. Intelligent Analog addressable inbuilt isolator rate of rise/fixed heat detector complete with dual LED b. Hard Addressable with rotary decade switches from or soft addressable facility through computer also c. 100% mechanical & electrical backwards compatibility d. In built short circuit isolator Laser Detector (Addressable) a. Intelligent analog addressable type high sensitivity laser based smoke detector having 9 sensitivity levels (from %/m) complete with dual LED b. Hard addressable having rotary multi rotary decades switches from or soft addressable facility through computer also c. 9 sensitivity levels( %/m) d. Twin LEDs for 360 degree visibility Multi Sensor Detector (Addressable) a. Functional both through smoke and heat sensitivity b. Intelligent analog addressable inbuilt isolator multi criteria type detector with dual LED c. Hard addressable having rotary decade address switches or soft addressing facility through computer also d. Bi color LED light for status monitoring e. Adjustable sensitivity through detector also f. In built short circuit isolator Certifications Required: UL/LPCB approved. Beam Sensor Detector (Addressable) e. Intelligent analog addressable type high sensitivity laser based smoke detector having 9 sensitivity levels (from %/m) complete with dual LED f. Hard addressable having rotary multi rotary decades switches from or soft addressable facility through computer also g. 9 sensitivity levels( %/m) h. Twin LEDs for 360 degree visibility
7 Certifications Required: UL/LPCB Manual Call point (Addressable) a. Unique plug & play installation concept b. In built short circuit isolator c. Integral loop isolation option d. Hard addressing facility and communicate with fire panels e. Backward compatibility f. Re-settable (non- breaking glass) via special key also g. Two part plug-in construction with base mounted termination allows easy installation and connection Certifications Required: UL/LPCB, Fire Hooter (Addressable) a. Storm and sounder facility b. Adjustable volume control by panel and device also. c. Simple familiar rotary wheel address control(hard integration) or soft integration by PC also d. Operate on 25 VRMS or with field selectable output taps from 0.5 to 2.0 watts e. Have at least 02 audibility options f. Low electric consumption Certifications Required: UL/LPCB Fire Repeater Panel (Addressable) a. Compatible with main fire alarm panel b. Back lit adjustable alphanumeric LCD displaying for all information like fire/fault etc. c. Local sounder mute and scroll alarm buttons d. Active or passive options e. Access Enable key- switch on active Certifications Required: UL/LPCB
8 Control Module (Addressable) a. Tri- colour Led status b. In built short circuit isolator c. Visible address selector switches or soft address through PC d. Minimum double output for control the device like fire damper, AHU tripping etc. e. In built additional provision of 24 VDC for power supply f. Compatible with IBMS of all platform g. Two part plug-in construction with base mounted termination for easy installation or surface mounting option Monitor Module (Addressable) a. Minimum two input for monitoring b. Tri colour LED status monitoring c. In built short circuit insulator d. Visible address selector switches or soft address through PC e. Status monitoring and compatible with IBMS of all platform f. Two part plug-in construction with base mounted termination for easy installation or surface mounting option g. In built additional provision of 24 VDC for power supply h. Provision for conventional item monitoring with address Response Indicator (Semi addressable, Conventional & Addressable) a. Single LED in red color b. Front cover marked FIRE c. Fabricated 16 SWG MS sheet d. Wide viewing angle e. Operating voltage 7 V DC to 26 V DC f. Suitable with all product g. Wide viewing angle ( at least 120 degree) Certifications Required: ERTL approved
9 Armored Cable (Semi addressable, Conventional & Addressable) a. 02 core 1.5 Sq.mm. armored cable with aluminum conductor b. Minimum 01 hr. fire retardant c. Armored & PVC schedules cables confirming to IS 1554 d. Fire Retardant Low toxic smoke (FRLS) cables e. Low HCL contents Certifications Required: ISI (IS 1554). Make: Polycab, R.R KABEL, Finolex. Battery (Semi addressable, conventional & Addressable) a. Sealed maintenance free b. Low self- discharge c. Eco- Friendly d. Excellent charge retention and recovering ability e. Minimum 20 hr back up at discharge 1.75V/cell f. Long service life g. Free from orientation constraints h. Approved by electric regulatory committee Make: EXIDE, AMARON GSM / PSTN Module (Semi Addressable & conventional) a. 03, 06, 09 input control facility b. Programmable I/O summary for software Connectivity with CMS c. Remote activation of outputs through caller recognition (zero charge) or by sending an SMS d. Can be installed inside panel cabinet ( no extra battery required) e. Can be used as a primary, backup or standalone communicator compatible with all control panels like security alarm, fire alarm & CCTV DVR Certifications Required: UL/LPCB approved Make: DSC, HONEYWELL, TEXECOM.
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationFIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19
TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as
More informationFire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
More informationAnalogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
More informationGlobal System Technology(UK) PLC The Intelligent Solution
Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor
More informationBARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
More informationFire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
More informationMINERVA MX MX Virtual Multi-Sensor Detectors
DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional
More informationDTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
More informationSFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
More informationSECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
More informationGST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
More informationFA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel
ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE
More informationElectronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
More informationPremier M Plus & Infinity 8
25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel
More informationFIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~
ID50 SYSTEM The Fire Alarm System can be activated in the following ways :~ 1. By breaking the glass in a Manual Alarm Call Point 2. By a rise in temperature activating an Automatic Heat Detector 3. By
More informationConventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
More informationBURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
More informationHONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
More informationINTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
More information25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals
INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce
More informationOverview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products
Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control
More informationFireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual
FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationINTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.
INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The
More informationQCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2
QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2 2.1 GENERAL...2 2.1.1 Scope 2 2.1.2 References 2 2.1.3 Contractor s Responsibility 2 2.1.4 System Description
More informationCB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
More informationMODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
More informationINTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
More informationRepeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
More informationAGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,
More informationResidential & Commercial Alarm Systems by Gross Security, LLC
151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training
More informationHAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete
More informationC. Conform to requirements of Americans with Disabilities Act (ADA).
SECTION 28 31 00 - FIRE ALARM AND DETECTION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire alarm and detection systems 1.2 REFERENCES A. NFPA 70 - National Electrical Code B. NFPA 72 - National
More informationSECURIT DEPARTMENT CIRCLE OFFICE 802,CHOPASNI ROAD JODHPUR-0291-2611213 (BY REGD POST) COJ/SEC/ BAC 19/05/2011. 2010
(BY REGD POST) SECURIT DEPARTMENT CIRCLE OFFICE 802,CHOPASNI ROAD JODHPUR-0291-2611213 COJ/SEC/ BAC 19/05/2011. 2010 ----------------------------------------- -----------------------------------------
More information(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
More informationD24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest
More informationFIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
More informationFIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
More information25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
More informationSecure Keypads for access control
torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary
More informationThe supplier and installer of the system should be approved by the local civil defence authority.
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer
More informationSECTION 16700 FIRE ALARM SYSTEM
SECTION 16700 FIRE ALARM SYSTEM PART ONE: GENERAL 1.1 GENERAL REQUIREMENTS A. Definition of Work : This section of the specification includes the furnishing, installation, connection and testing of the
More informationControl/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
More informationSECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
More informationAutomatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
More informationD287/D288/D292/D293A/D293E
D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization
More informationNC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
More informationCONTENTS 4. HOW TO UNSET THE PANEL...7
Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs
More informationAUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
More informationGSM Voice Auto Dialer & SMS Sender JC-999
GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C
More informationNJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
More informationFire alarm system EBL512 G3
Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands
More informationExpansion Modules & Accessories
HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationSecurity Systems Intrusion Alarm
Dufferin-Peel Catholic District School Board STANDARD TEXT GUIDELINE FOR Security Systems for SECONDARY AND ELEMENTARY SCHOOLS Prepared by the Plant Department With Assistance from Vision Dynamics Formatted
More informationVEGA Analogue Addressable Control Panels
Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed
More informationEDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk
More informationSFC-200 SERIES LCD FIRE ALARM PANEL
SFC-200 SERIES LCD FIRE ALARM PANEL User Guide LT-954SUM SFC-200 Series LCD Version User Guide Contents Introduction... 1 About this Manual... 1 Technical Support... 1 Main Display... 1 The Buzzer and
More informationDiscovery 1-4 Loop Analogue Addressable Control Panel Application Guide
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware Specifications 7 4.0 Software
More informationS100. GSM House Alarm System. Http://www.GSMalarmsystem.com
S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It
More informationFire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
More informationSECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM
SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION 25-POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1. DESCRIPTION: A. This section of the specification
More informationBold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted
More informationwelcome to our world fire alarm systems - series 600 www.staticsystems.co.uk
Static Systems Group PLC Heath Mill Road, Wombourne Staffordshire WV5 8AN. United Kingdom. Tel: +44 (0) 1902 895551 Fax: +44 (0) 1902 324969 www.staticsystems.co.uk welcome to our world In line with our
More informationconventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
More informationUSER MANUAL, MAINTENANCE GUIDE & LOG BOOK
Software Versions: PANEL 1.52 & LOOP CARD 2.0 ONE TO FOUR LOOPS ANALOGUE ADDRESSABLE FIRE ALARM PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK #Doc No. GLT.MAN-135 TABLE OF CONTENTS WHAT TO DO IF THE
More informationSECTION 16721 FIRE ALARM AND DETECTION SYSTEM
1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this
More informationOWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada
2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) OWNER S MANUAL 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada Tel: (604) 420-1585 Fax: (604) 420-1591 http:// www. statpower.com PROsine 2.5/3.0 ACS Panel
More informationFire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?
5/2/2014 Fire Alarm FAQs Question Answer Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need? A: The size of a fire alarm panel is determined by a number of factors,
More informationIPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
More informationIDS X-Series User Manual 700-398-01D Issued July 2012
1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...
More informationSECTION 16721 FIRE ALARM AND DETECTION SYSTEM
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification
More informationCAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
More informationHARDWIRED CONTROL PANELS
USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting
More informationDIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 13 00 SECURITY AND ACCESS CONTROL SYSTEM
DIVISION 28 ELECTRONIC SAFETY AND SECURITY PART 1 GENERAL 1.01 DESCRIPTION A. Division 28 Contractor shall extend a complete Matrix Systems Access Control System as shown on the Drawings and as specified
More informationQCS 2014 Section 23: Fire Fighting and Fire Alarm Systems Page 1 Part 01: General
QCS 2014 Section 23: Fire Fighting and Fire Alarm Systems Page 1 Part 01: General 1 GENERAL... 2 1.1 INTRODUCTION... 2 1.1.1 Scope 2 1.1.2 General 2 1.2 REGULATIONS... 2 1.2.1 Electrical Installations
More informationnr 28 nr 68 nr 4 nr 1
SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R:
More informationConsultant s Guide for Fire Detection & Alarm Systems for Buildings
section one specification for a digital addressable fire system Consultant s Guide for Fire Detection & Alarm Systems for Buildings section one specification for a digital addressable fire system section
More informationDetector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
More informationUsing your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationwww.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
More informationE2-E3: ELECTRICAL CHAPTER-13 FIRE PROTECTION SYSTEM- EVOLVING TRENDS AND APPLICABILITY TO DATA CENTRE
E2-E3: ELECTRICAL CHAPTER-13 FIRE PROTECTION SYSTEM- EVOLVING TRENDS AND APPLICABILITY TO DATA CENTRE BSNL, India For Internal Circulation Only Page: 1 Fire Protection System- Evolving Trends & Applicability
More informationSMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
More informationGSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
More informationWD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
More informationCM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
More informationC E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems
P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationNESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL
NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia
More informationPRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
More informationAlways on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
More informationFire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction
Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are
More informationARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.
ARCHITECT AND ENGINEER SPECIFICATION SECTION 13850 DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE DSC MAXSYS PC4020 V3.5 Rev0x2 Digital Security Controls 3301 Langstaff Rd., Concord, ON Canada L4K
More information500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
More informationINTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM Intelligent Fire Alarm & Emergency Communications Network MMX-LOC MMX-BBX-FXMNS Description Secutron s MMX TM Series Mass Notification System (MNS) is designed
More information3. MOUNTING THE FIRE ALARM PANEL... 7 3.1 PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL
INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL 1.3 ABOUT THE PREMIER SX FACP & INTEGRAL PSE 1.4 DESIGNING THE SYSTEM 1.5 EQUIPMENT GUARANTEE 2. FIRST FIX GUIDELINES.
More informationABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance