Premier M Plus & Infinity 8
|
|
|
- Randall Simon
- 10 years ago
- Views:
Transcription
1 25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330
2 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel (PMP8, PMP16, PMP24) The Premier M Plus control panels are designed to fulfil the requirements of EN54 parts 2 & 4 as well as being easy to install, operate and maintain. Being of modular construction, the basic M Plus panel has 8 zone capacity, expandable to 16, 20 and 24 zones. The Premier M Plus is suitable for surface mounting or semi-flush fitting (with just the door protruding) CPD Common sounder circuits (150mA each) Optional add-on zonal sounder circuits (50mA Max.) Serial repeater output Auxiliary supply (29 Volts, 250mA) Zone & sounder disablement facility Sounder delay facility Zonal to common timer (when fitted with zonal sounder boards) One man test mode Model PMP8 PMP16 PMP24 Part No Detection Zones Mains Voltage 230V AC +10% / 50/60 Hz System Voltage 24V DC (nominal) Zone Voltage 21V DC Sounder Alarm Output 4 x 24V DC Fault Relay Output 1 x relay 1A maximum Fire Relay Output 1 x relay 1A maximum Zone Capacity 32 Devices Remote Sounder Activation N/A Sounder Activation Delay 0 9 minutes in 1 minute increments Zone End Of Line IN4002 Diode Sounder End Of Line 10KΩ Resistor Charger Voltage 28.4V DC (batteries disconnected) Zone Short Circuit Protection 100mA Charger Short Circuit Protection Batteries less than 20V Charger Size 3.0 Amp Operating Temperature 0 C - 50 C Enclosure Size 485 x x 125mm 2
3 Premier M Plus Repeater Panel (PMP-REP, PMP-REP/M) The Premier M Plus repeater is available in 2 versions standard (PMP-REP) & multiple (PMP- REP/M). The standard repeater offers display & control functions, however it is limited to one per system. The second version allows multiple repeaters on the same system however they do not have any control functions (i.e. they cannot be used to silence or reset the system). A single repeater can be powered from the panels auxiliary 24V supply. If more than one repeater is to be used, a separate 24V is required. Model PMP-REP PMP-REP/M Part No Functions Display & control Control only Supply Voltage 20-30V DC Max. Quantity Per System 1 5 Serial Repeater A Connections Serial Repeater B +24V DC 0V Operating Temperature 0 C to 50 C Enclosure Size 375 x 335 x 125mm Weight TBC 3
4 Infinity 8 Conventional Fire Alarm Panel (IN1, IN2, IN4, IN6, IN8) The Infinity 8 control panel is housed in the most attractive, modern designed, flame retardent ABS enclosure, utilising a switch mode power supply. It has a fully removable front cover which improves ease of access for cable installations. Optional Metal Backbox The Infinity 8 panel can also be ordered with a metal back box facilitating upto 7ah batteries to fit within the panel housing. To order this version add /M to the end of the model number (i.e. IN1/M, IN2/M, etc.) 0086-CPD KM Access via password removes problem of lost keys 371mm One man test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 302mm 4 sounder circuits (IN4, IN6 & IN8) Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies Meets all requirements of latest EN54 part 2 and part4 MODEL IN1 IN2 IN4 IN6 IN8 Part No Mains Voltage 230V AC +10% / 50/60 Hz System Voltage 24V DC (Nominal) Zone Voltage 21V DC (Nominal) Sounder Alarm Output 2 x 24V DC 4 x 24V DC Fault Relay 1 x Volt Free Relay, 1A Max Fault Relay 1 x Volt Free Relay, 1A Max Zone Capacity 32 devices per zone Remote sounder operation Via N/O contact connected to Class Change Sounder Activation Delay 0 to 10 minutes in 1 minute increments Zone End of line 1N4002 Diode (Cathode Stripe to Zone +ve) Sounder End of Line 10K resistor Charger Voltage 27.6V Battery cut off Battery voltage less than 20V Battery Internal Resistance limit 0.9 ohm Enclosure size 375 x 316 x 90 (mm) Weight 3 kg (Excluding Batteries) Maximum battery space 2 x 3.4 Ah, 12 Vdc sealed lead acid 4
5 Fyreye MkII Conventional Detectors (MKII-OP, MKII-OH, MKII-HF, MKII-HR) The Fyreye MkII optical smoke detectors use a pulsing IR LED & photodiode to detect IR scatter caused by smoke entering the chamber. MKII-OP DIFT See table below for CPD numbers MKII-OH The detector is particularly suitable for detecting optically dense smoke, involving materials such as soft furnishings, PVC, plastic, foam and all similar materials which produce small visible particles (0.5 to 10μm). The Fyreye Rate of Rise heat detectors (MKII-HR) use a thermistor arrangement to sense a quick rise in temperature and also a final threshold temperature of 57 C. The Fyreye fixed heat detector (MKII-HF) has a single thermistor arrangement that gives an alarm at a temperature of 90 C. MKII-HF MKII-HR Designed to meet EN54 requirement Lockable to base to stop unauthorised removal Remote LED output Compatible with all Fyreye bases Model FEII-OP FEII-OH FEII-HF FEII-HR Part No Detector Class Optical Smoke Combined Smoke & Heat Fixed Heat Only Rate of Rise & Fixed Heat Detector Design Standard EN54 part 7 EN54 parts 5 & 7 EN54 part 5 EN54 part 5 Approval DIFT CPD Number 0845-CPD CPD CPD CPD Operating Voltage 9-33V DC Quiescent Current 40μA Alarm 24V DC 34mA Operating Temperature -10 C to +50 C Minimum Continuous Temperature 0 C Maximum Humidity 95% RH non-condensing Alarm Condition 2.4% obscuration per metre Fixed heat C Rate of rise or fixed heat 57 C Coverage 100m² 50m 2 IP Rating IP43 Start-up Time 10 Seconds Size (with Base) 100 x 48 mm 101 x 64 mm 100 x 48 mm 100 x 48 mm Weight (with Base) 75g (133g) Bases There are 4 types of mounting base available; standard or deep and with or without diode. Model MKII-CB MKII-CB/D MKII-DB MKII-DB/D Part No Type Common Base Common Base Diode Base Diode Base Size 100 x 16mm 100 x 32mm 100 x 16mm 100 x 32mm Weight 53g 64g 53.2g 64.2g 5
6 Reset Call Point & Waterproof Reset Call Point (ZT-CP3, ZT-CP3/WP) ZT-CP3 DIFT ZT-CP3/WP The ZT-CP3 and ZT-CP3/WP call points are unique in that they mimic the feel of breaking glass whilst offering the user the benefits and environmental advantages of a re-settable operating element. The CP3 uses a simple yet ingenius patented mechanism which consists of a rigid plastic operating element and an over centre spring mechanism. This arrangement provides real action on operation and simulates break glass activation. An activation indicator drops into view at the top of the window after the CP3 has been operated. The unit is then simply reset with a key and is ready for re-use straight away. A special Polycarbonate cover (CP3-CV) is available for extra protection against accidental activation and thus allowing the unit to operate as a double action call point. This must be ordered seperately. Flush Mount Installation An optional flush mount bezel is available for the indoor ZT-CP3 call point and can be ordered under the code CP3-FMB. EN54-11 approved ZT-CP3 Back Box Waterproof tested to IP67 (ZT-CP3/WP only) 119mm 62mm 93mm 26mm Glass appearance maintains operator deterrence Positive activation that mimics the feel of breaking glass 128mm 94mm Visible warning flag confirms activation Simple key to reset operating element (no broken glass) ZT-CP3/WP CP3-CV Complete functional test with every activation Model ZT-CP3 ZT-CP3/WP Current Rating (All Series) 3 Amps 12-24V DC (Series & 11) 3 Amps V AC (Series 01 & 11) 3 Amps 12-24V DC (Series 11) 3 Amps V AC Low Current Rating (All Series) ma 5-12V DC 0.1 Amps V AC Housing and Mounting Box Material Polycarbonate Electrical Contact Material Silver plated brass Operating Temperature -20 degrees C to +65 degrees C Installation Terminal Conductor Size 0.5mm - 2.5mm Colours Red, Yellow, Green, Blue & White Mounting Flush or surface with back box IP Rating IP32 IP67 6
7 Zeta Beam Motorised Reflective Optical Beam Smoke Detector (ZT-BEAM, ZT-BEAM/KIT80, ZT-BEAM/KIT100) ZT-BEAM 0786-CPD Developed to overcome the problems of old outdated technology in beam detection, this motorised beam now means that beam detection can be used reliably to produce cost effective solutions for protecting large areas. Building movement and accessibility have in the past, made beam detection unreliable, difficult, time consuming to commission and hard to maintain, but now by using the advanced motorised technology of thefirebeam unreliability is no longer a problem. The ZT- BEAM will self align itself to the centre of the reflector when commissioning and will automatically keep alignment with the reflector when building movement occurs. This intelligent motorisation will mean less false alarms therefore saving time, resources, reputations and ultimately money. Connection Diagram fire panel or zone monitor module addressable loop ZAZM-MI Motorised head unit Controller unit (mounted at low level) Designed to comply with EN54 part 2 Compatible with most major fire panels Very low power consumption Uses only 3mA at all times power supply Additional System Components detector controller ZT-BEAM/KIT80 Mid range kit for distances between 40 and 80 metres. ZT-BEAM/KIT100 Long range kit for distances between 80 and 100 metres. Order Information For 40m Beam ZT-BEAM For 80m Beam ZT-BEAM + KIT/80 For 120m Beam ZT-BEAM + KIT/100 ZT-BEAM/KIT80 ZT-BEAM/KIT100 For Zone Monitor Module ZAZM-MI 7
8 Miditone Conventional Sounder & Combined Sounder/Flasher (ZMDD/8R, ZMDD/8W & ZMDF/8R) ZMDD/8R ZMDD/8W The Miditone sounders and combined sounder/ flashers are small, high output conventional devices which are designed to meet EN54 part 3 and are CE marked. The device is a compact unit that fits a standard European back box and can be either surface or flush mounted. It has a choice of 8 tone patterns, selectable by an internal dip switch and a sound output of 1m with volume control. It is available in red or white to meet architectural requirements and also as a combined sounder/flasher with a red lens. ZMDF/8R Complies to EN54 part 3 1m sound output 8 Tone patterns Flush or surface fixing Model ZMDD/8R ZMDD/8W ZMDF/8R Part No A Sound Output See current consumption table Colour Red White Red Operating Voltage 9-30V DC 17-30V DC Quiescent Current 0mA Alarm 24V See current consumption table Operating Temperature -10 C to 50 C Minimum Continuous Temperature 0 C Maximum Humidity 95% RH Non Condensing IP Rating IP43 Size (with Back Box) 85 x 85 x 35mm (85 x 85 x 67mm) Weight (with Back Box) 100g (150g) 112g (162g) DIL Switch Settings (SW4 N/A) ZMDD/8R, ZMDD/8W ZMDF/8R Tone Description db Level Current (ma) db Level Current (ma) Off Off Off Sweep Negative Hz In 1 Second 97 (+/ (+/- 35 On Off Off Alternating 554 and 440Hz 0.5s Each 95 (+/ (+/- 27 Off On Off Continuous 660Hz 96 (+/ (+/- 33 On On Off Alternating 0.4s 94 (+/ (+/- 26 Off Off On Intermittent 0.5s On/Off 93 (+/ (+/ On Off On Continuous 970Hz 95 (+/ (+/- 37 Off On On Sweep Positive Hz 99 (+/ (+/- 45 On On On Alternating 800 and 0.25s Each 100 (+/ (+/- 42 8
9 Maxitone Conventional Sounder & Combined Sounder/Flasher (ZMT/8R, ZMT/8W & ZMTF/8R) ZMT/8W The Maxitone sounder is an ideal alternative to fire bells and for external use. It is housed in an attractive horn comprises of flame retardant ABS. Eight selectable tones and volume control are featured to meet most requirements. The Maxitone is also available with transparent polycarbonate front which will provide both visual and audible alarm. ZMT/8R High output 8 selectable tones Volume control ZMTF/8R Model ZMT/8R ZMT/8W ZMTF/8R Part No A Sound Output See current consumption table Colour Red White Red Operating Voltage 17-30V DC Quiescent Current 0mA Alarm 24V See current consumption table Operating Temperature -20 C to 60 C Minimum Continuous 0 C Temperature Maximum Humidity 95% RH non condensing IP Rating Size Weight IP x 130 x 100mm 357g DIL SWITCH SETTINGS (SW4 N/A) Tone Description db Level Off Off Off On Off Off Sweep Negative Hz In 1 Second Alternating 554 and 440Hz 0.5s Each Off On Off Continuous 660Hz On On Off Off Off On Alternating 0.4s Intermittent 0.5s On/Off On Off On Continuous 970Hz Off On On On On On Sweep Positive Hz Alternating 800 and 0.25s Each 101 (+/- 98 (+/- 101 (+/- 98 (+/- 98 (+/- 103 (+/- 103 (+/- 102 (+/- Current (ma)
10 Zeta Conventional Fire Alarm Bells (ZTB6B, ZTB8B/230, ZTB8B & ZTB8B/WP) ZTB6B ZTB8B 152mm 152mm 55mm The Zeta motorised fire alarm bells combine styling and functional efficiency. They incorporate a low power rotary centrifugal mechanism, which gives a high sound output with low current consumption at 24V dc. The bells are available in 2 sizes; 6 (152mm) and 8 (203mm). These sizes suit a wide variety of installations. 203mm 55mm There is a 230V ac version of the 6 bell, and a 24V dc Weatherproof version of the 8 bell. Low current 203mm Universally accepted fire evacuation signal Model ZTB6B ZTB8B/230 ZTB8B ZTB8B/WP Part No Supply Voltage 18-30V dc V AC 18-30V dc Diameter 6 (152mm) 8 (203mm) Quiescent Current 25mA 28mA Nominal 1M 95dB(A) 97dB(A) Dimensions 152 x 152 x 55mm 203 x 203 x 55mm Weight 860g 960g 1700g 1800g 10
11 Other Conventional Ancillaries PP-2/12 PP-5/17 Premier Power Pack EN 54-4 Power Supply with LCD Screen The Premier Power Pack Power supply uses an innovative design that allows the engineer to view system status through the on board LCD screen. The screen can display several power supply parameters, including output voltage, and output current CPD CPD-0146 Zeta Sealed Lead Acid Batteries As with all life safety systems a fire alarm system must function is the event of a mains power failure. All parts of the system, including auxiliary power supplies, must have a battery back-up. Z21751 Z21251 Z20651 Z20304 Z20201 ZT-DR24 ZT-BR Zeta Magnetic Door Holders The Zeta magnetic door holders are designed to retain a fire door open against the force of its own closing device. In the event of a fire, the door holder magnet can be turned off by the fire alarm, allowing the door to shut. Fyreye Conventional Ultra-Violet Flame Detector The Fyreye ultra-violet flam detector is particularly suited to applications where flames can be expected to develop initially rather than smoke. This is typically due to the nature of the materials being protected for instance camera film, computer, audio & video tapes or disks. FEUV2000 UV/IR & Triple IR (IR3) Flame Detectors The new range of UV/IR and Triple IR Flame Detectors detect fuel and gas fires at long distances with the highest immunity to false alarms. ZT-20EX ZT-500EX ZT-20P Remote LED Indicators Remote LED indicators are used in installations where a detector going to alarm is likely to occur out of sight (for instance behind a locked door or in a ceiling void). In these scenarios the remote LED will show the location of the alarm. Both ceiling and wall mounted versions are available and the enclosure matches the styling of the MKII detectors for consistency. MKII-RL/C MKII-RL/W For further details visit 11
12 Other Zeta Products 25 Years of Manufacturing Excellence 25 Years of Manufacturing Excellence Premier Quatro Simplicity Plus Addressable Fire Alarm System 25 Years of Manufacturing Excellence 007 Addressable Fire Alarm System Assessed to ISO 9001: 2008 Certificate number 330 INFINITY 007 Assessed to ISO 9001: 2008 Certificate number 330 The 2 Wire Fire Detection System for Professionals 007 Assessed to ISO 9001: 2008 Certificate number Years of Manufacturing Excellence Gas Sense Gas Detection System Premier EVACS 16 Voice Alarm System eclipse Security Alarm Systems Available now from: Tel: +44 (0) Fax: +44 (0) [email protected] Web: Detection House Morfa Road Swansea SA1 2EN United Kingdom
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals
INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
AlarmSense 2-wire detection and alarm system. Product Guide
AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority
Analogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
Conventional Fire Alarm Systems
Conventional Fire Alarm Systems Contents Introduction 3-7 Zeta UV/IR Optical Flame Detectors 26-27 Premier SX Conventional Fire Alarm Panel 8 Premier Elite Conventional Fire Alarm Panel 9 Premier Conventional
CB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
Addressable Fire Alarm Systems
Addressable Fire Alarm Systems Contents Introduction 3-7 Premier AL -4 Loop Analogue Addressable Fire Alarm Panel 8-9 Premier AL 5-8 Loop Analogue Addressable Fire Alarm Panel 0 Premier AL: Addressable
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
conventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
CB200 1 8 Zone Conventional Control Panel
CB200 1 8 Zone Conventional Control Panel > features Built-in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User-friendly
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
Fire Detection Product Range
Fire Detection Product Range World Leading Fire Detection Products from the NITTAN group Issue 1.0 Business Overview The Nittan Group has been at the forefront of the fire protection industry since 1954
Emergency Voice Communication Systems EVCS Network 8 Data Sheet
Emergency Voice Communication Systems EVCS Network 8 Data Sheet The Emergency Voice Communications System (EVCS) Network 8 is for use as a Fire Telephone system, Disabled Refuge Call system or as a combined
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19
TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as
Fire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
3. MOUNTING THE FIRE ALARM PANEL... 7 3.1 PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL
INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL 1.3 ABOUT THE PREMIER SX FACP & INTEGRAL PSE 1.4 DESIGNING THE SYSTEM 1.5 EQUIPMENT GUARANTEE 2. FIRST FIX GUIDELINES.
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
MINERVA MX MX Virtual Multi-Sensor Detectors
DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional
VEGA Analogue Addressable Control Panels
Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
Fire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems
P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier
HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
HART HSSD High Sensitivity Smoke Detection
HART HSSD High Sensitivity Smoke Detection The HART High Sensitivity Smoke Detection system (HSSD) is an Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient
Fire & Security DETECTORS
Fire & Security DETECTORS Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions
The supplier and installer of the system should be approved by the local civil defence authority.
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer
Global System Technology(UK) PLC The Intelligent Solution
Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
ICP-CP500. User's Guide ICP-CP500 Codepads
ICP-CP500 EN User's Guide ICP-CP500 Codepads ICP-CP500 User's Guide 1.0 ICP-CP500 Series Codepads Overview EN 2 1.0 ICP-CP500 Series Codepads Overview The codepad is the communications interface between
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Section D..General Auto Electrical Corporation
43 Section D..General Auto Electrical Corporation 1. LED Based Signal unit GAEC manufacture LED based signaling system for use in electrified and non electrified sections of Indian railways. The exceptional
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2
QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2 2.1 GENERAL...2 2.1.1 Scope 2 2.1.2 References 2 2.1.3 Contractor s Responsibility 2 2.1.4 System Description
CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual
CONTENTS Installation Precautions... 1 EN 54 Information... 2 Chapter 1 Product Overview... 3 1.1 Features... 3 1.2 Technical Specifications... 3 1.2.1 Operating Voltage... 3 1.2.2 Batteries... 4 1.2.3
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
DTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Emergency voice communications Product Name
Product Name 76 EATON FIRE AND VOICE ALARM SYSTEMS CFCC2556 January 2015 Contents Contents Emergency voice communications Panels Network exchange units 78 Non network exchange units 80 Devices Outstations
Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work
GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle
INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL
FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT-201-7-1 CONTENTS 1. INTRODUCTION... 1.1 HANDLING THE PCBS... 1.2 USING THIS MANUAL... 1.3 ABOUT THE INFINITY FIRE ALARM CONTROL PANEL
SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
USER MANUAL, MAINTENANCE GUIDE & LOG BOOK
Software Versions: PANEL 1.52 & LOOP CARD 2.0 ONE TO FOUR LOOPS ANALOGUE ADDRESSABLE FIRE ALARM PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK #Doc No. GLT.MAN-135 TABLE OF CONTENTS WHAT TO DO IF THE
INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.
INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
MSL1000 Monitored Serial Link Interface Manual V1.01
Audix Systems, Station Road, Wenden, Saffron Walden, Essex, CB11 4LG. Telephone: +44(0)1799 540888 Facsimile: +44(0)1799 541618 www.tycosafetyproducts-europe.com www.audixsystems.co.uk MSL1000 Monitored
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications
Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
GST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
Communication A BRITISH MANUFACTURER. Features:
care2 Radial Wired Emergency Voice Communication Manufacturing EVC systems since 2001 CARE2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall.
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE
EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE User manual v1.5 Compatible with: ESIM264 v7.09.02 and up. ESIM364 all versions. Main features: Hardwired zone expansion adding 16 additional zones per
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware Specifications 7 4.0 Software
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION
SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION A. This section of the specifications includes the furnishing, installation, and connection of the microprocessor-controlled
Life Alarm Fire Alarm Controls
FIRE SUPERVISORY SUPV SILENCED SILENCE AC POWER RESET UL, ULC Listed FM Approved MEA Approved* Life Alarm Fire Alarm Controls Fire Alarm Controls 4005 Series Fire Alarm Control Panels Eight through Thirty-Six
welcome to our world fire alarm systems - series 600 www.staticsystems.co.uk
Static Systems Group PLC Heath Mill Road, Wombourne Staffordshire WV5 8AN. United Kingdom. Tel: +44 (0) 1902 895551 Fax: +44 (0) 1902 324969 www.staticsystems.co.uk welcome to our world In line with our
AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810
AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810 This Manual and the information contained therein is the property of AMI Marine (UK) Ltd. It must not be reproduced
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
PLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Fire Detection Systems
Fire Detection Systems contents conventional fire alarm systems 4 intelligent fire alarm systems 9 detector application guide 15 conventional fire alarm systems principle of operation A conventional fire
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
Fire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
D287/D288/D292/D293A/D293E
D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization
Sound Engineering for 60 Years EmerCall Disabled Refuge and Fire Telephone System
EmerCall Disabled Refuge and Fire Telephone System Slide 1 Audix EmerCall Fully Compliant to BS5839 Part 9 Slide 2 Audix EmerCall One System for Fire phones and Disabled persons See BS5839 Part 9 Forward,
EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:
Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM
FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system
FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0