TECHNICAL MANUAL SAILOR SC4000 IRIDIUM

Size: px
Start display at page:

Download "TECHNICAL MANUAL SAILOR SC4000 IRIDIUM"

Transcription

1 TECHNICAL MANUAL SAILOR SC4000 IRIDIUM

2 Introduction Your Iridium equipment is a modular system that consists of a transceiver unit, control handset unit, antenna unit and an optional analogue PSTN telephone/pabx. You can make and receive voice calls on the control handset and the analogue PSTN telephone. You can connect up to four handsets and one analogue PSTN telephone or PBX switchboard to the system. The system provides intercom for internal calls between any control handsets and between the analogue telephone and a control handset. Via the data port on the transceiver, the unit can be used as a data modem for dial-up data calls, Internet access, SMS and messaging. Please note Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed. The information in this manual is furnished for informational use only, is subject to change without notice, may contain errors or inaccuracies, and represents no commitment whatsoever. This agreement is governed by the laws of Denmark. Doc. no.: M4150GB0 Issue: H/

3 IRIDIUM Installation Contents 1 Technical Specifications Installation Version Overview Configuration of Single-Channel Unit Cable Overview Scanbus Termination Where to Place the Satellite Transceiver Box How to Mount the Satellite Transceiver Box How to Put on the Finishing Cover How to Insert the SIM Card Optional SIM card Reader How to Remove the Finishing Cover Installation of the Antenna Analogue telephone Data Interface External Ringer Interface Reset Button Appendix A Spare Parts List

4 Installation IRIDIUM 1 Technical Specifications Space Segment Satellites 66 (Plus 6 in-orbit backup satellites) Orbital planes 6 Orbit height 780 kilometres Inclination of the orbital planes 86.4 degrees Orbital period 100 minutes, 28 seconds Spot beams 48 per satellite Radio module Frequency Range Duplexing Method Oscillator Stability Input/Output Impedance 1616 MHz to MHz (L-Band) TDD (Time Domain Duplex) ± 1.5 ppm 50 Ω Multiplexing Method TDMA/FDMA Average Power during a transmit slot (max) 7W Average Power during a frame (typical) 0.6W Receiver Sensitivity at 50 Ohm (typical) dbm Receiver Spurious Rejection at offsets > 1 MHz (typical) 60 db Voice/Data Rate 2.4 kbit/s QPSK Antenna Helical, omni-directional 210 (3 db beam width) Fibreglass radome ø 96 mm Link Margin 16 db Antenna Tracking Capability Turn Omni-directional antenna Roll/pitch Up to ± 20 from horizontal position Yaw Elevation > 8 Interface Handset 600 Ω / 4 wire RS485 Telephone/PABX 270 Ω +750 Ω // 150nF / 2 wire Data RS232 with hardware flow control Position information NMEA

5 IRIDIUM Installation Power supply DC AC (Optional) Consumption Environmental Conditions Transceiver Operating temperature Storage temperature Antenna Temperature Rel. humidity Icing (survival only) Precipitation Wind (velocity) Vibration Weight Transceiver : Antenne: Handset & cradle : 10 32V DC V AC (External adaptor) 25 W during communication 8 W Stand by -10 C to +55 C -30 C to +70 C EME -35 C to + 55 C Up to 95% at 40 C Up to 25 mm of ice Up to 100 mm/hour Up to 100 knots IME: g EME: g 2.7 kg 220 g 570 g 3

6 Installation IRIDIUM 2 Installation 2.1 Version Overview This manual covers the Transceiver Unit versions Mk2, Mk3 and Mk4. The version can easily be determined by looking at the area around the SIM card reader. Also check the part number on the type label located at the antenna connector. Mk2 Mk3 Mk xx xx xx 2.2 Configuration of Single-Channel Unit Iridium Antenna Unit Transceiver Unit Control Handset Control Handset Max. cable loss 3dB Connection Box GPS Phone PABX DTE L E 10-32V DC L2 L1 + L2 < 100 metres 4

7 IRIDIUM Installation 2.3 Cable Overview Cable 1 Scanbus Cable: 9*0.22 mm 2 shielded Cable connector type: shield connected to ground 9 pole sub-d male Transceiver Description Handset Colour 1 NC 1 2 data+ 2 white Twisted 3 data- 3 brown pairs 4 AF+ 4 green Twisted 5 AF- 5 yellow pairs 6 GND 6 grey Twisted 7 +24V DC 7 pink pairs 8 RX_AF+ 8 blue Twisted 9 RX_AF- 9 red pairs shield GND shield Cable 2 Phone Cable connector type: RJ 11 Transceiver Description 1 NC 2 phone1+ 3 phone1-4 NC Cable 3 Data Cable: 9*0.22 mm 2 shielded shield connected to ground Cable connector type: 9 pole sub-d male Transceiver Description 1 DCD 2 received data 3 transmitted data 4 data terminal ready 5 serial GND 6 data set ready 7 request to send 8 clear to send 9 RI shield GND Cable 4 Power supply Pin no. Description Colour V DC red 2 0V DC black 3 NC white 4 GND green Front view A 5

8 X3 X8 X5 Z16 Z14 R66 R128 R62 Z13 C25 Z8 Z10 Z9 Z11 Z12 C124 C77 C78 R19 R162 Z42 C228 Z35 C93 Z40 C76 Z36 C94 Z37 C95 Z38 C96 Z39 C97 Z41 C227 R41 R44 C26 V33 V31 V15 V20 R78 R77 R54 V16 N14 R59 V14 C16 C136 C137 Z6 C134 R109 S3 D10 C40 R55 R50 C133 V17 R110 R60 D8 R51 R154 C175 C169 R107 R106 C156 C208 C48 R113 C176 C174 R86 C6 N2 C189 C191 R114 R116 C148 R150 R94 C205 R117 N12 R125 C53 R90 R91 C181 C204 R2 C11 C31 C187 C178 C173 R87 C170 C49 R112 R115 R92 C158 C186 C188 C190 C161 C182 N15 C167 R149 C55 R89 R93 C226 Z3 R17 R53 R32 R47 C38 R46 C130 V12 V26 V11 V27 V19 C220 R58 R52 V28 R24 C39 R57 V80 R16 N16 V21 C85 R230R9 C52 C59 C34 C60 V13 C135 R25 C2 D14 C37 C43 C219 C51 R42 R245 R244 R239 R240 X10 C139 D16 C107 C12 C155 C150 C32 R84 R169 C225 R168 C236 C194 C22 R167 R224 C4 R155 C23 C207 N4 C57 C61 R100 R104 C200 C109 C125 C68 R121 R43 R13 R152 C192 C108 R10 C172 N5 N8 C106 C171 R183 R108 C17 R118 C110 R119 N1 N13 C99 C111 C223 C3 R220 C224 C115 R120 C13 C193 R103 C67 R1 R3 D7 C105 R4 R221 V75 R219 R218 R105 C114 C84 D6 D5 C62 C113 R124 C74 R88 R98 C218 C162 R101 R99 R97 R96 C101 D4 D1 R185 C147 R123 C41 C234 R83 R22 R12 R11 C24 C199 C20 C27 R38 R40 Z2 S6 C35 C217 C177 C72 C131 C196 C9 C103 V77 C5 V57 R6 C86 R39 Z4 R216 D12 R198 V60 R197 V49 V45 R34 C14 V66 V68 C28 C36 X2 C209 C120 C154 N9 C142 C210 V61 R199 R35 V62 R200 C152 R214 C65 C138 C144 V55 R195 C145 V56 R196 C151 L7 C206 C153 C149 C119 C141 C146 C168 C118 T2 V63 R188 V50 C127 R79 V64 R130 V38 V54 T1 C73 R212 V39 C140 R133 C66 C211 V43 V67 R211 V35 N6 C185 R215 R171 R145 V44 R148 C63 R138 V30 R144 R204 N10 R140 C104 R184 C143 R179 V36 R141 V65 R207 R177 R178 N11 C112 N7 V47 R203 R174 R182 R170 R208 R209 R142 R172 C159 R206 C75 R147 R165 C128 C33 V37 L5 R143 C197 V48 R134 R136 C126 R37 V42 R194 R193 V32 R137 R80 R81 C69 V51 R190 R189 V52 R131 R139 V53 V46 C116 R191 C129 R192 Installation IRIDIUM Cable 5 Description of connections to T-connection H4196 (optional accessory) The wire terminal blocks are connected in parallel Scanbus Termination The scanbus connecting the transceiver and the control units, has to be terminated. Only the first and last unit on the bus shall have the termination in ON position. The termination in the transceiver unit is done by setting the jumper S3, located near the scanbus terminal on the PCB (see figure below). As default, the jumper S3 is set ON. R225 R166 C1 C132 V6 D9 R151 C98 R135 C213 C157 R8 R45 R7 X4 C102 C232 C29 V5 R85 C64 V1 V71 C233 X9 C229 R26 R18 R20 R21 R247 R27 R31 R30 R33 R14 X7 C231 C90 C89 R213 C123 C179 C42 C164 C212 D17 Z15 C91 C160 T3 C88 C122 X6 C165 C44 C121 R56 R64 D26 R49 R61 C198 F1 L4 V74 C216 V40 C117 C100 D15 D18 D2 R36 C230 V41 C92 V34 R210 C18 C19 C30 C195 C21 R63 R237 S4 C15 R48 D3 C8 C54 S5 C10 C163 C7 S2 R236 R5 V78 V82 R23 V76 C56 V79 V81 R246 C50 C184 R175 C183 C166 C180 R235 V3 V2 V4 V7 X12 S C134 R156 R29 R28 Cable 6 GPS input Cable: 9*0.22 mm 2 shielded shield connected to ground Cable connector type: 9 pole sub-d male Description Transceiver Mk2 & Mk3 MK4 1 NC* External Ringer 2 PC Rx (RS232) PC Rx (RS232) 3 PC Tx (RS232) PC Tx (RS232) 4 NC* NC* 5 GND (RS232) GND (RS232) 6 NC* NC* 7 NMEA+ NMEA+ 8 NMEA- NMEA- 9 NC* NC* shield GND GND S3 R A R217 R15 The termination in the control unit is located on the PCB in the cradle as jumper S1 (see figure below). As default the jumper S1 is set ON. S1 ON OFF R231 R232 R242 R248 R234 R233 * Do only connect a standard RS232 terminal cable. If only NMEA needed, then do not connect to other pins than 7 and

9 IRIDIUM Installation When configuring a system only including a transceiver unit and one control unit, no changes in the default termination is needed. If the system includes more than one control unit, it is needed to remove some of the default terminations. Below two examples of scanbus termination is given, when the system includes several control units. Transceiver Unit Control Unit Connecting more control units When connecting more than one control unit the extension number for each control unit must be set prior to operation. The control units must have different extension numbers. Connect one control unit at a time and set the extension number according to the Instruction manual. Set extension: Enter MENU, enter SETUP, Choose EXTENSION and enter a number from 1 to Press ok to store the setting. Terminated Terminated Connection Box Transceiver Unit Control Unit Terminated Terminated Connection Box

10 Installation IRIDIUM 2.4 Where to Place the Satellite Transceiver Box Mount the satellite transceiver box in a place where it is sheltered from the wind, protected from the salty and humid sea atmosphere. The temperature must not exceed 55 C. To ensure that the SIM card is easily accessible, do not place the satellite transceiver box higher than 1.5 m above the floor. First tighten three of the screws. The wall surface should be plane. If there is a discrepancy in planeness exceeding 1 mm, level the discrepancy up by shims or washers under the fourth screw before this is tightened. 2.5 How to Mount the Satellite Transceiver Box Fix the satellite transceiver box to the wall using the four screws included in the package. The screws are positioned as shown below: 2.6 How to Put on the Finishing Cover When the satellite transceiver box has been mounted on the wall, put on the finishing cover. The small lid in the finishing cover should be shut. Press the hooks inside the finishing cover down on the two thin edges of the satellite transceiver box. While pressing, let the two plastic spears inside the finishing cover into the two square holes of the satellite transceiver box. 8

11 IRIDIUM Installation Lift the SIM card holder so that the slot points upwards. Press hard on the spots shown in the picture below until a loud click is heard. Insert the SIM card in the slot. Make sure that the cut-off corner of the card is placed as shown in the picture. When putting on the finishing cover, do not use any tools only your hands. 2.7 How to Insert the SIM Card First, open the small lid in the finishing cover protecting the SIM card reader. Then go through each of the following steps: Unlock the SIM card holder by pushing the lock with your finger nail. Push the SIM card holder back down, and lock it by pushing the lock with a finger nail. Finally, shut the lid again. 9

12 Installation IRIDIUM 2.8 Optional SIM card Reader Only direct accessible on Mk3 units produced from August 16, On older units the L-Band transceiver must be dismounted in order to install the SIM card. This additional SIM card reader can be used as a master SIM card, thus allowing the crew to place individual cards in the primary SIM card reader on the front. The primary SIM card reader on the front has highest priority and will thus disable the card in the optional card reader when a card is inserted. The optional card reader is ideal for Ship Security and Alert installations, where a permanent SIM card is required. 2.9 How to Remove the Finishing Cover You may need to dismount the satellite transceiver box from the wall, e.g. in connection with service. For access to the mounting screws, the finishing cover can be removed from the satellite transceiver box as follows: Put a screwdriver into the slot in the printed circuit board beside the SIM card reader, and press gently to unhook the plastic spear. While pressing with the screwdriver, lift up the same side of the finishing cover slightly to loosen it. Repeat this procedure on the other side of the finishing cover. You can now detach the finishing cover from the satellite transceiver box by pulling it gently upwards. Remove the lid by removing the 2 umbraco screws. After inserting the card put the lid back on. 10

13 IRIDIUM Installation 2.10 Installation of the Antenna One of the advantages of this equipment is the easy-tohandle, lightweight and rugged antenna. Because the IRIDIUM system is characterised by a good link margin, the antenna is a passive quadrifillar helix type, requiring no external power supply and consisting of only nonmoving parts. The following figures show the antenna and the two different mounting accessories available: The mounting bracket in fig. 1 can be used in two different ways - mounted on either a rail or a pole. The fitting in fig. 2 can be used at the top of a tube. Please note that it is necessary to mount the cable, and seal this connection securely before the antenna and fitting are mounted on the tube. Important! To comply with FCC RF exposure regulations, the antenna must be installed in a location providing a minimum RF Radiation Safety Distance of 0.61m (2 feet). ø96mm Antenna Four M4 washers Angle mounting bracket Four M4 serrated lock washers Four M4x10 Pipe clamp Antenna Two M8 U-bolts Four M4 washers Angle mounting bracket Four M4 serrated lock washers Four M4x10 Pipe clamp Two M8 U-bolts 2" pipe 206mm Four M8 lock nuts and M8 washers 2" pipe Four M8 lock nuts and M8 washers 2" pipe 36623B Fig. 1 Fig. 2 Antenna cable Below, please find a table of cables that can be provided by your dealer: CABLE CONNECTOR Cable type Part no. Maximum Minimum Outer Conn. length/ 3 db bending diameter type loss radius Part no. RG 214/U E m 10.8 mm 54 mm N MALE E SUCOFEED 1/2" HF m 13.4 mm 35 mm N MALE SUCOFEED 1/2" m 16.0 mm 125 mm N MALE SUCOFEED 7/8" m 27.8 mm 220 mm N MALE & FEMALE Important! It is important that the antenna cable used has a maximum loss of 1.6GHz between antenna and transceiver. This antenna cable must be in one piece. Neglecting this will reduce the overall receiving/transmitting performance at sea. If installation is not carried out in accordance with these guidelines, it will void the warranty of the product. 11

14 Installation IRIDIUM Precautions In order to avoid interference or any other kind of disturbances from other systems on board, there are a few precautions to take note of: Radars According to any installation guide for radars it is of vital importance that any other units are kept outside the radiation beam of the radar. Please consult the illustration down below, showing what area to avoid: Inmarsat equipment The operating frequency bands of the iridium and Inmarsat systems are neighbours, and it is not in any way by any technical solution possible to completely separate these bands. This means that interference from Inmarsat can be expected, especially if the antennas are placed near each other. The distance between the antennas Should be as far as possible. Avoid interference e.g. from the radar Unobstructed view until 10 below the horizon A GPS Tests have shown that only in case very old GPS equipment is used, a user may expect a minor influence on the GPS originated from the Iridium equipment. This can be avoided by ensuring a distance of at least 1 m between the two antennas. If in any way the user experiences trouble using Iridium because of Inmarsat, a filter can be provided as an option. This filter is placed in a suitable place between the antenna and the transceiver. The filter is a passive type not requiring external power. Please contact your dealer for further information. 12

15 IRIDIUM Installation The table below shows the distance to other Inmarsat equipment, with and without use of filter. Main Lobe Side Lobe Back-Lobe 9505 ISU Protection Distance (Metres) (Metres) (Metres) No Filter Inmarsat (Mini-M) No Filter Inmarsat (Std-M) No Filter Inmarsat A No Filter Inmarsat B No Filter Inmarsat C With Filter Inmarsat (Mini-M) With Filter Inmarsat (Std-M) With Filter Inmarsat A With Filter Inmarsat B With Filter Inmarsat C 2.11 Analogue telephone The PSTN interface on the transceiver unit converts the wireless Iridium network into an ordinary telephone line. You can connect a standard analogue PSTN telephone directly to this interface for crew calling or as an office phone. With a PABX you can add more telephone lines for multiple phones ie. office network. The interface handles the following tasks: generates DC current to the phone/pabx in both idle and active mode generates ringing voltage detects call requests from a phone/pabx detects DTMF tones from a phone/pabx outputs 12 or 16kHz billing tone for a PABX Important: Do not connect the transceiver to a PSTN telephone line on land. Specification of the Iridium system PSTN connection: RJ11 connection: 1. NC 2. TIP 3. RING 4. NC Line Voltage: Line current (source): Line impedance: 48V DC 24 ma 270 Ω Ω // 150 nf (this impedance also covers 600 Ω) Ringing voltage: 60V RMS, 90 Vpp (square wave) Ringing sequence: 0.6 sec On, 4 sec Off Ringing frequency: 30 Hz Ringing drive capability: Hz (= 5 normal ring units) 13

16 Installation IRIDIUM Iridium Satellite network Note: Some analogue phone line impedance may differ from the commonly used standards. If the ringing volume is too low, the ringing voltage can be changed to gain higher output. The selector switch is located under the finishing cover. Iridium Antenna Unit Transceiver Unit Open 60V RMS Pin V RMS Pin V RMS Max. cable loss 3dB Trunk line analogue Iridium Antenna Unit Transceiver Unit Max. cable loss 3dB PABX PSTN NET PABX with analogue trunk line

17 IRIDIUM Installation 2.12 Data Interface The Iridium transceiver unit can be used as a 2.4kbps data modem. Connect a PC via a serial COM port to the 9 pole data connector using a standard serial data cable. The data interface is a full RS232 interface with hardware flow control Reset Button The reset button is placed next to the SIM card reader. Pushing this button will halt the power supply and remove power from the transceiver unit. When releasing the button, the power will come back and thereby make a power reset of the transceiver unit. With the SMS/ client installed on a PC you can receive and send Iridium SMS and short s from the PC. The SMS/ client is included in the transceiver package. To use the transceiver as a data modem a dedicated modem software driver is needed. Please contact your Iridium Service Provider, who can supply you with the Iridium Data Interface software External Ringer Interface The external ringer output pin in the Service/NMEA port can control an optional ringer or a lamp. This is very useful in noisy environments or when there is a need for ringing indication at more locations. The output is an open collector output and can pull down a signal of max 32V DC and a power dissipation of max 1.25W. The output is pulsing at 0.5 Hz whenever there is an incoming call. When the call is answered the output will stop pulsing. Power Supply Isolated from Main X5 Pin 1 Alarm Switch Max 32V DC Max 1.25W Alarm Horn/ Sirene

18 Installation IRIDIUM 16

19 IRIDIUM Installation Appendix A Spare Parts List Mk2 Mk3 Mk Item Itemnumber Itemnumber Itemnumber Power cable TNC/N adaptor N.A. Coax cable with TNC male - N female N.A * ID kit Fuse Scanbus male 9p Sub-D Scanbus female 9p Sub-D Housing 9p Sub-D Handset spiral cable Connection box H *) introduced in production August 16, Replacing TNC/N adaptor

20 Thrane & Thrane A/S

SAILOR SC4000 IRIDIUM KEEP IN TOUCH FROM POLE TO POLE

SAILOR SC4000 IRIDIUM KEEP IN TOUCH FROM POLE TO POLE SAILOR SC4000 IRIDIUM KEEP IN TOUCH FROM POLE TO POLE TRULY GLOBAL, TRULY REASONABLE Keeping in touch with the shipping company, other ships or with loved ones at home is vital for any vessel crossing

More information

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply INSTALLATION MANUAL SAILOR 5080 AC Power Supply Contents Introduction... 3 General description... 3 Technical data... 3 Installation... 4 Outline and dimension... 4 Installation wiring... 5 Block diagram

More information

SAILOR C4900/C4901 Installation Manual

SAILOR C4900/C4901 Installation Manual SAILOR C4900/C4901 Installation Manual Introduction SAILOR The communication products and systems of Thrane & Thrane are recognized under the brand name SAILOR. The Sailor name has become a guarantee of

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter. ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations

More information

GSM1000 The Orchid Mobile Gateway. Benefits & Feature List

GSM1000 The Orchid Mobile Gateway. Benefits & Feature List GSM1000 The Orchid Mobile Gateway. Benefits & Feature List The Gateway to cost savings A Fixed Cellular terminal with Full Call Divert - getting the most Benefits from your mobile phone s free minutes

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS 1. Locate a suitable position inside the building to install the Base Station enclosure where mains power (240V AC) is available

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This

More information

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Prepared by: Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling, VA 20166 Copyright 2004

More information

FWT-8848 GSM (GATEWAY) USER S MANUAL

FWT-8848 GSM (GATEWAY) USER S MANUAL FWT-8848 GSM (GATEWAY) USER S MANUAL COPYRIGHT -2009 1 ST VERSION 1 1,General Description: FWT-8848 is a GSM to Analog Converter(single port,insert 1 sim card only), the device can produce a FXS line to

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Technical description MX-1 VB Edge

Technical description MX-1 VB Edge 1 (7) Technical description MX-1 VB Edge 2 (7) Table of Contents 1 General description...3 2 Connectors...4 3 ON/OFF operation...5 4 Power...5 5 LED indicators...6 6 Enclosure...6 7 Mounting...6 8 and

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) 1. Description and Specifications Contents 1.1 Description 1.2 1.2 Specifications 1.3 1.3 Tested parameters in production

More information

PCS300 Universal IP Reporting Module V1.0

PCS300 Universal IP Reporting Module V1.0 PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

SAILOR RT4822 VHF-DSC Installation Manual

SAILOR RT4822 VHF-DSC Installation Manual SAILOR VHF-DSC Installation Manual Introduction SAILOR The communication products and systems of Thrane & Thrane are recognized under the brand name SAILOR. The Sailor name has become a guarantee of reliable

More information

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers USB to router s serial port How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers by Neo at RouterTech.Org Introduction Routers based on the AR7RD/AR7WRD

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

SYSTEM 45. C R H Electronics Design

SYSTEM 45. C R H Electronics Design SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25

More information

Remote Satellite Terminal RST100. Installation and User Manual. BEAM Communications Pty Ltd

Remote Satellite Terminal RST100. Installation and User Manual. BEAM Communications Pty Ltd Remote Satellite Terminal RST100 Installation and User Manual BEAM Communications Pty Ltd Remote Satellite Terminal RST00 Installation and User Manual BEAM Communications Pty Ltd 8 Anzed Court, Mulgrave,

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Business/Home. GSM Alarm system

Business/Home. GSM Alarm system Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900

More information

SAILOR H3000M SSA Mini-C. Ship Security Alert System

SAILOR H3000M SSA Mini-C. Ship Security Alert System SAILOR H3000M SSA Mini-C Ship Security Alert System Ship Security Alert System With more than 50 years experience in the maritime market, SAILOR is a leading developer and manufacturer of communications

More information

Innovative DOOR STATION Solutions

Innovative DOOR STATION Solutions Innovative DOOR STATION Solutions When a visitor arrives at your front door or gate we ring... Your mobile when you are out Your normal telephones in your home Your PABX system in your office Communicating

More information

G3 Fax. SKIPPER 150 FleetBroadband (FB) Ver : 1.0

G3 Fax. SKIPPER 150 FleetBroadband (FB) Ver : 1.0 G3 Fax SKIPPER 150 FleetBroadband (FB) Ver : 1.0 Date : 31 July 2012 Contents Introduction 3 Product Overview 3 General Feature 4 Technical Setup 5-6 Technical Specification 7-8 Ordering Information 9

More information

SAILOR H4122 Iridium Ship Security Alert System Operating / Installation Manual

SAILOR H4122 Iridium Ship Security Alert System Operating / Installation Manual SAILOR H4122 Iridium Ship Security Alert System Operating / Installation Manual Introduction Thank you for choosing our equipment and Congratulations on Your new Iridium Ship Security Alert System. We

More information

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4 MoTeC USA GPS Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4 MoTeC USA GPS Copyright Motec Systems USA 2008 The information in this document is subject to change without notice. While

More information

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide 8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

MS900AC-B-LS User Information

MS900AC-B-LS User Information MS900AC-B-LS User Information MS900-R-AC-B-LS systems equipped with MR900 Micro Receiver are Receive-Only. MS900-X-AC-B-LS systems equipped with MX900 Micro Transceiver will Send and Receive. The model

More information

GSM Voice Auto Dialer & SMS Sender JC-999

GSM Voice Auto Dialer & SMS Sender JC-999 GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C

More information

PRO 5000 CPE 1D Quick Installation Guide

PRO 5000 CPE 1D Quick Installation Guide PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM XE0402LCC January 2007 Miniature Surface-Mount DAA for Audio or Data Transfer Description The XE0402LCC supplies a complete telephone line interface or DAA (Data Access Arrangement) in a miniature, surface-mount

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

5-port 10/100Base-TX Industrial Switch (314500) User s Guide 5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

FM Radio Transmitter & Receiver Modules

FM Radio Transmitter & Receiver Modules FM Radio Transmitter & Receiver Modules T5 / R5 Features MINIATURE SIL PACKAGE FULLY SHIELDED DATA RATES UP TO 128KBITS/S RANGE UPTO 300 METRES SINGLE SUPPLY VOLTAGE INDUSTRY PIN COMPATIBLE QFMT5-434 TEMP

More information

User manual Compact Web PLC WP240 series IEC-line

User manual Compact Web PLC WP240 series IEC-line User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

WPR400 Wireless Portable Reader

WPR400 Wireless Portable Reader P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support. Contents

More information

Outdoor-Ready Box. Hardware Manual KCM-5211E, KCM-5311E KCM-5511, KCM-5611. Ver. 2014/10/15

Outdoor-Ready Box. Hardware Manual KCM-5211E, KCM-5311E KCM-5511, KCM-5611. Ver. 2014/10/15 Outdoor-Ready Box Hardware Manual KCM-5211E, KCM-5311E KCM-5511, KCM-5611 Ver. 2014/10/15 Table of Contents Precautions 3 Safety Instructions... 4 Introduction 6 Package Contents... 6 Physical Description...

More information

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited Neo-Neon LED Vision Mesh Screen Operation Manual He Shan Decorative Lighting Company Limited LED Display Engineering Department 1 Contents Chapter1 Specification and Function Parameters 3 Chapeter2 Structure

More information

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0 M72 Quectel Cellular Engine EVB User Guide M72_EVB_UGD_V1.0 Document Title EVB User Guide Version 1.0 Date 2011-05-18 Status Document Control ID Release M72_EVB_UGD_V1.0 General Notes Quectel offers this

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved

TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved Copyright 2003, Advanced Tracking Technologies, Inc. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D Tele Eye DT Series Dialup CCTV Transmitter DT-103G DT-103P DT-103D Installation Guide Notice: Signal Communications Limited reserves the right to make improvements to the product described in this manual

More information

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution

More information

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Dallas Delta Corporation Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Email: sales@dallasdelta.com.au www.dallasdelta.com.au LP GUARD DOORSTATION MK II G UARD Doorstation

More information

Business/Home GSM. Alarm System(III) Installation and Users guide

Business/Home GSM. Alarm System(III) Installation and Users guide Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment

More information

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram XE0204 July 2000 2-Wire/4-Wire Telephone Line Interface Description The XE0204 provides a common telephone interface for networks integrating two and four-wire telephone connections. The XE0204 supplies

More information

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1 Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions

More information

IP Indoor High Speed Dome. CAM-6500 series. Ver. 070307. Quick Installation Guide

IP Indoor High Speed Dome. CAM-6500 series. Ver. 070307. Quick Installation Guide IP Indoor High Speed Dome CAM-6500 series Ver. 070307 Quick Installation Guide 1 1 Getting Started 1.1 PACKAGE CONTENTS CAM-6500 series Warranty Card Software CD Power & A/V Cable LAN/WAN Cable Alarm Cable

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C

Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C /Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers

More information

InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1

InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1 InnoMedia ESBC 9580-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED

More information

Model 70A00-1. GSM Cellular Communications Center

Model 70A00-1. GSM Cellular Communications Center Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40

More information

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011 WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 1 Disclaimer The following warranty

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

FOM-5A, 6A. Asynchronous Fiber Optic Modem

FOM-5A, 6A. Asynchronous Fiber Optic Modem FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

GSMPBX version 1.3 Datasheet

GSMPBX version 1.3 Datasheet GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the

More information

STATUS POWER MONITOR ALARM SOS DISARM

STATUS POWER MONITOR ALARM SOS DISARM STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings

More information

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

FN2001-A1 Network module (SAFEDLINK) Mounting Installation FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without

More information

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal

More information

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec, Inc. Such proprietary information and materials

More information

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual 577013-859, Rev. B

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual 577013-859, Rev. B INTRODUCTION This Installation Guide Contains the necessary information to Connect the Wireless Modems to the EMR³ Interconnect Box and the Office Computer for running the EMR³ Datalink Program. For Specific

More information

Introduction Ericsson Handheld Telephone 1341-B

Introduction Ericsson Handheld Telephone 1341-B Ericsson Handheld Telephone 1341-B 2 Contents General 5 The Mobile Telephone Network 6 Base Station and Cell 7 Radio Channels 7 Radio Coverage 8 Transmission Control and Communication 9 Quality Control

More information

4.3-inch Back-Up Camera

4.3-inch Back-Up Camera TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION

More information

Maestro Heritage. GSM GPRS Modem 850 / 900 / 1800 / 1900 USER MANUAL Rev. 03

Maestro Heritage. GSM GPRS Modem 850 / 900 / 1800 / 1900 USER MANUAL Rev. 03 Maestro Heritage GSM GPRS Modem 850 / 900 / 1800 / 1900 USER MANUAL Rev. 03 www.maestro-wireless.com Email: contact@maestro-wireless.com Tel: 852 2869 0688 Fax: 852 2525 4701 Address: Room 3603-3609, 36/F,

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 1999-2007 by Laipac Technology, Inc. All rights reserved The Specifications and information regarding the products in this manual

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

INSTALLATION MANUAL XM3 Reader

INSTALLATION MANUAL XM3 Reader INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

ADSL Modem Installation Guide. Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

ADSL Modem Installation Guide. Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000. ADSL Modem Installation Guide ADSL Modem Installation Guide Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000 ADSL Modem Installation Guide Installation Instructions Westell ADSL Modem 1. Package Inspection and Contents...2

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information