Fax (603) (603)
|
|
- Alexis Ellis
- 7 years ago
- Views:
Transcription
1 FEDERAL POWER TM PRODUCT CATALOG X L P E XLPE Insulated Power Cables Federal Power Sdn Bhd ( V) Lot 8, Jln Ragum 15/17, P.O.Box Shah Alam, Selangor West Malaysia Tel (603) /601/602 Fax (603) (603) Website: / coercial@federalpower.com.my Designed by : Information Systems Dept
2 CONSTRUCTION 600/1000V XLPE/PVC Power Cable Insulation Fillers Binder tape Outer sheath 3.6/6-18/30 kv XLPE/PVC Power Cable shelding (Semi-conducting layer) Insulation Insulation shielding (Semi-conducting layer) Metallic shielding Fillers Binder tape Outer sheath Single core Three core 600/1000V XLPE/SWA/PVC Power Cable 3.6/6-18/30 kv XLPE/SWA/PVC Power Cable Insulation Fillers Binder tape Separation sheath Steel wire armour Outer sheath shielding (Semi-conducting layer) Insulation Insulation shielding (Semi-conducting layer) Metallic shielding Fillers Binder tape Separate sheath Steel wire armour Outer sheath Notes: SWA : Steel wire armoured 1
3 CONSTRUCTION 11kV up to 33kV AI-XLPE/SWA/PE Cable ; Hard drawn aluminium shielding Insulation: XLPE Insulation shielding Metallic shielding: Copper tape Fillers Binder tape Bedding: Black polyethylene Armour : Galvanized steel wire Outer sheath: Black polyethylene 11kV up to 33kV AI-XLPE/PE Aerial Cable shielding Insulation Insulation shielding Metallic shielding Binder tape Sheath: Black HDPE Messenger wire : Galvanized steel wire 2
4 CONSTRUCTION Cross-section 600/1000 V AI-XLPE/SWA/PE Cable : Hard drawn aluminium, sector shape Insulation: XLPE Fillers: Polypropylene yarn Binder tape: Plastic tape Bedding: Black polyethylene Armour: Galvanized steel wire Outer sheath: Black-termite repellent polyethylene Core identification : Core identification shall be made by coloured insulation compound. Cable identification : Outer sheath shall be embossed. Cross-section 11 kv up to 33 kv AI-XLPE/PE Aerial Cable : Hard drawn aluminium shielding Insulation : XLPE Insulation shielding: Metallic shielding: Annealed copper tape Sheath: Black HDPE Messenger wire: Galvanized steel wire Cross-section 11 kv up to 33 kv AI-XLPE/SWA/PE Cable : Hard drawn aluminium shielding Insulation: XLPE Insulation shielding Metallic shielding Fillers: Polypropylene yarn Binder tape Bedding: Black polyethylene Armour: Galvanized steel wire Binder tape Outer Sheath: Black termite repellent polyethylene 3
5 11kV up to 161kV XLPE/PE Cable with Copper wire screen CONDUCTOR (Copper or aluminium) CONDUCTOR SHIELD INSULATION (XLPE) INSULATION SHIELD SWELLABLE TAPE METALLIC SCREEN (Copper wires) BINDING TAPE OUTER SHEATH 4
6 11kV up to 132kV XLPE/LC/PE or PVC with lead sheathed CONDUCTOR (Copper or aluminium) CONDUCTOR SHIELD INSULATION (XLPE) INSULATION SHIELD LEAD SHEATH OUTER SHEATH 5
7 11kV up to 132kV XLPE/AWA/PE or PVC with Aluminium wire screen CONDUCTOR (Copper or aluminium) CONDUCTOR SHIELD INSULATION (XLPE) INSULATION SHIELD SWELLABLE TAPE METALLIC SCREEN (Aluminium wires) BINDING TAPE OUTER SHEATH 6
8 Technical Data CONTINUOUS CURRENT CARRYING CAPACITY The tabulated current rating have been calculated in accordance with IEC 287. They are for single circuit with the standard conditions as follow:- i) Maximum permissable conductor temperature at continuous operation is 90 deg. C ii) Ground temperature is 25 deg.c iii) Ambient temperature is 40 deg.c iv) Ground thermal resistivity is 1.2 Km/W v) Cables laying depth is ground:- - s voltage up to 1kV s voltage above 1kv 800 vi) Spacing between s:- -In flat formation.2 times the. -In trefoil formation.s touching. vii) Cable s sheath or armour solidly bonded at both ends viii) Cables shielded from direct sun rays For conditions operation different from those on which the continuous current carrying capacity tables are based, ratings can be determined by application Rating Factor in table below. Rating Factor Rating Factor For Cables In Air Ambient air temperature Rating Factor Rating Factor For Ground Temperature Ground temperature Rating Factor Rating Factor For Thermal Resistivity Ground size (2) Thermal Resistivity (K.m/W) Single Core Cable Up to 150 From 185 to 400 From 500 to Multicore s Up to 16 From 25 to 150 From 185 to Depth laying (m) Rating Factor For Depth Laying 0.6 / 1 kv s 1.9 / 3.3 kv to 19 / 33 kv s up to to 300m2 above 3002 up to 3002 above or more
9 Group Derating Factors Derating Factors for groups s installed in air Multiple circuits Number vertically 1 2 Number horizontally Spacing S = d S = 2d S = 3d Number vertically 3 Number s horizontally N/A Spacing S = d S = d2 S = 3d Number s horizontally Number vertically + + S + + S + + d S Derating Factors for groups s laid direct in ground Cable Voltage (kv) 0.6/1 1.9/3.3 to 12.7/22 19/33 Number circuit Trefoil Touching Laid flat * This spacing will not be possible for some the larger s. Three single core s in trefoil and laid flat touching, horizontal formation Spacing circuit (between centres s groups) 0.15m* 0.3m 0.45m 0.6m Derating Factors for groups s laid direct in ground Multicore s in horizontal formation Cable Voltage (kv) Number Of circuits Spacing circuits (between centres groups) Touching 0.15m* 0.3m 0.45m 0.6m 0.6/1 1.9/3.3 to 12.7/ / * This spacing will not be possible for some the larger s. 8
10 Handling and installation XLPE 1. Minimum bending radius and permissible maximum pulling tension. For safety installation without damaging electrical and physical properties, the following minimum bending radius and permissible maximum pulling tension must be observed. Minimum bending radius D: Overall dia. Of Type Number core Round conductor Single core Four segmental stranded conductor Multi core 600 V 10D 12D 8D 3,300 V and higher 10D 12D 8D Triplex type - - 8D Corrugated metal armoured 10D 12D 8D Flat tape armoured 10D 12D 8D Wire armoured 10D 12D 10D Lead sheathed 10D 12D 10D Permissble maximum pulling tension Pulling tool Material conductor Permissible maximum pulling tension (kg) Pulling eye Copper 7 x (Number core) x (Core-sectional area conductor) Aluminium 4 x (Number core) x (Core-sectional area conductor) Cable grip Copper & aluminium The same as using the pulling eye, but the minimum tension should be less than two tons Note : When grip is used it should cover more than 500 in length end be bound to the sheath. 2. Side wall pressure to 3. Removal sheath or tape Special care must be taken not to harm the insulation Permissible maximum side wall pressure to the at when removing the sheath or tapes with knife otherwise bending point during installation is 500 kg/m. it may results in a dielectric breakdown. Note : pulling tension (kg) = T 4. Cleaning the surface insulation Side wall pressure to The surface insulation should be cleaned to avoid a bending radius (m) R flash over at the termination or joint. T : Pulling tension (kg) R : Bending Radius (m) R 5. Applying self-adhesive tape When applying a self-adhesive tape after joint or terminating XLPE, stretch it properly about 1.2 times as long as the original one. If it is over-stretched crack may occur on the tape will not be adhered between each layer. 6. Water pro treatment for out-door termination For out-door termination water pro treatment is necessary to avoid the water penetrating into the end and special care must be taken to apply tapes and terminals. It is desirable to use a compression to solder type terminal. Side wall pressure T 9
11 DIMENSIONAL TABLE XLPE / PE or PVC For Aluminium and Copper 600/1000 V XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Nominal Shape thickness Approximate cross sectional weight weight area sheath sheath (Cu) (AL) sq kg/km kg/km Compact round stranded /1000V Multi-core XLPE/PE Power Cable, Type XLPE/PE Nominal Three core Four core Cross Approx sectional Shape weight weight weight weight area insulation sheath (copper) (alu) sheath (copper) (alu) sq kg/km kg/km kg/km kg/km Compact round stranded
12 DIMENSIONAL ` TABLE, XLPE / PE or PVC 0.6/1 kv-xlpe/pe.lv-continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Core 4 Core 4 Core 4 Core 4 Core 4 Core 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)
13 DIMENSIONAL TABLE, XLPE / PE or PVC 1.9/3.3 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded /6.6 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded
14 DIMENSIONAL TABLE XLPE / PE or PVC 3.6/6 kv XLPE/PE.MV-Continuous Current Rating Factor (100%-Load) Condu- in-air at 40 0 C in-ground at 30 0 C in-duct conductor ctor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)
15 DIMENSIONAL TABLE, XLPE / PE or PVC 6.35/11 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded /15kV XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded
16 DIMENSIONAL TABLE, XLPE / PE or PVC 12.7/22 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded /33kV XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded
17 DIMENSIONAL TABLE, XLPE / PE or PVC 6.35/11kV to 19/33 kv-xlpe/pe.mv-continuous Current Rating Factor (100%-Load) in-air at 40 0 C in-ground at 30 0 C in-duct conductor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)
18 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE For Aluminium and Copper 600/1000 V Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded
19 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 0.6/1 Kv-XLPE/SWA/PE or PVC.LV-Continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Core 4 Core 4 Core 4 Core 4 Core 4 Core 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)
20 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 1.9/3.3 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded /6.6 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded
21 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 3.6/6 kv XLPE/SWA/PE or PVC MV-Continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)
22 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 6.35/11 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded /15 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded
23 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 12.7/ 22 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded /33 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded
24 DIMENSIONAL 1 TABLE, XLPE / SWA/PVC or PE 6.35/11 19/33 kv-xlpe/swa/pe.mv or PVC-Continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)
25 DIMENSIONAL TABLE, Copper, XLPE / CWS/PE or PVC 38/66 kv XLPE INSULATED POWER CABLE Copper, XLPE/CWS/PE or PVC Nominal Outside thickness Shape jacket size insulation () (2) ) () ) Weight (kg/km) DC resistance (Ω /km) Electrostatic capacity (µf/km) Compact Round Stranded Four 1000 Segmental Stranded Aluminium conductor,xlpe/pe or PVC Nominal Outside thickness Shape jacket size insulation () (2) ) () ) Weight (kg/km) DC resistance (Ω /km) Electrostatic capacity (µf/km) Compact Round Stranded Four 1000 Segmental Stranded
26 DIMENSIONAL TABLE, XLPE / CWS/ PE or PVC 76/132kV XLPE Insulated Power Cable with Copper Wire screen Aluminium, XLPE/CWS/PE or PVC size (2) Shape ) Nominal thickness insulation () jacket () Outside ) Weight (kg/km) DC resistance (Ω /km) Electrostatic capacity (µf/km) Compact Round Stranded Four 1000 Segmental Stranded Continuous current ratings (load factor = 100%) In ground In air In duct Size (2) Trefoil Flat Trefoil Flat Trefoil Flat (A) (A) (A) (A) (A) (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Aluminium cond
27 DIMENSIONAL TABLE, XLPE / CWS/ PE or PVC 76/132kV XLPE Insulated Power Cable with Copper wire screen Copper conductor, XLPE/CWS/PE or PVC size (2) Shape ) Nominal thickness insulation () jacket () Outside ) Weight (kg/km) DC resistance ( Ω/km) `Electrostatic capacity (µ F/km) Compact Round Stranded Four 1000 Segmental Stranded Continuous current ratings (load factor = 100%) In ground In air In duct Size (2) Trefoil Flat Trefoil Flat Trefoil Flat (A) (A) (A) (A) (A) (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond
28 DIMENSIONAL TABLE XLPE/PE or PVC 93/161 kv XLPE insulated Power Cable with Copper wire screen. Copper, XLPE/PE or PVC size (²) Shape ) Nominal thickness insulation () jacket () Outside ) Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Continuous current ratings (load factor = 100%) Size (²) Trefoil (A) In ground In air In duct Flat (A) Trefoil (A) Flat (A) Trefoil (A) Flat (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond
29 DIMENSIONAL TABLE XLPE/LC/PE or PVC 38/66 kv Lead Sheathed Cable Copper, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Continuous current ratings (load factor = 100%) Size (²) Trefoil (A) In ground In air In duct Flat (A) Trefoil (A) Flat (A) Trefoil (A) Flat (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond
30 DIMENSIONAL TABLE XLPE/PE or PVC 38/66 kv XLPE Insulated Lead Sheathed Cable Aluminium conductor, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Continuous current ratings (load factor = 100%) In ground In air In duct Size (²) Trefoil (A) Flat (A) Trefoil (A) Flat (A) Trefoil (A) Flat (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond
31 DIMENSIONAL TABLE XLPE/PE or PVC 76/132 kv XLPE Insulated Lead Sheathed Cable Copper conductor, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Aluminium conductor, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded
32 DIMENSIONAL TABLE XLPE/PE or PVC 38/66 kv XLPE Insulated Power Cable Aluminium Wire Screen Copper conductor, XLPE/ AWA /PE or PVC size (²) Shape ) Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x Aluminium conductor, XLPE/ AWA / PE or PVC size (²) Shape () Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x
33 DIMENSIONAL TABLE XLPE/PE or PVC 63/132 kv XLPE Insulated Power Cable with Aluminium Wire Screen Copper conductor, XLPE/ AWA /PE or PVC size (²) Shape () Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x Aluminium conductor, XLPE/ AWA / PE or PVC size (²) Shape ) Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x
34 Some Of The Various Utility Specified Cables 600/1000 V Four Core XLPE/SWA/PVC, Steel Wire Armoured Power Cable, Type XLPE/SWA/PVC Cross sectional area sq Shape Nominal thickness insulation separation sheath under wire armour wire outer sheath weight (Cu) kg/km weight (AL) kg/km Compact round stranded /11kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power Cable, Type XLPE/SWA/PVC Cross sectional area sq Shape Nominal thickness insulation separation sheath under wire armour wire outer sheath weight (Cu) kg/km weight (AL) kg/km Compact round stranded /33 kv Three Core XLPE/SWA/PVC, Wire Armoured Power Cable, Type XLPE/SWA/PVC Cross sectional area sq Shape Nominal thickness insulation separation sheath under wire armour wire outer sheath weight (Cu) kg/km weight (AL) kg/km Compact round stranded
35 Some Of The Various Utility Specified Cables 600/1000 V Four Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Cross sectional area sq 25 Shape thickness insulation separation sheath lead sheath separation sheath Approx under armour armour wire outer sheath 95 Compact round stranded Approx weight (Cu) /11 kv Three Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx thickness Cross Shape separation lead separation armour sectional under insulation sheath sheath sheath wire area armour sq 25 outer sheath Compact round stranded /33 kv Three Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx Nominal thickness Cross Shape separation lead separation armour sectional under insulation sheath sheath sheath wire area armour sq 25 outer sheath Compact round stranded kg/km Approx weight (Cu) kg/km Approx weight (Cu) kg/km weight (AL.) kg/km weight (AL.) kg/km weight (AL.) kg/km 34
36 Some Of The Various Utility Specified Cables 6.35/11 kv Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC cross sectional area sq 25 Shape thickness insulation separation sheath lead sheath separation sheath Approx under armour armour wire outer sheath 150 Compact round stranded Approx weight (Cu) kg/km weight (AL.) kg/km 12.7/22 kv Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx thickness cross separation lead separation armour outer sectional Shape under insulation sheath sheath sheath wire sheath area armour sq Compact round 240 stranded Approx weight (Cu) kg/km weight (AL.) kg/km 19/33 kv Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx thickness cross separation lead separation armour outer sectional Shape under insulation sheath sheath sheath wire sheath area armour sq Compact round stranded Approx weight (Cu) kg/km weight (AL.) kg/km 35
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationEDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationHigh Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationTHE PATHWAY TO POWER HIGH-VOLTAGE CABLES
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationMV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationSCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
More informationPower and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
More informationCurrent Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69
Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationLOW VOLTAGE POWER CABLES
LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationRemoval of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document standards@asa.transport.nsw.gov.au www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More informationHIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide
HIGH VOLTAGE XLPE CABLE SYSTEMS Technical User Guide Content 1. General information on High Voltage XLPE Cable Systems 1.1. Introduction 1.2. Cable selection process 1.3. Service life 3 3 3 4 2. Cable
More information6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables
6-36kV Medium Voltage Underground Power Cables XLPE insulated cables Cable solutions to ensure the reliability of your energy network 2 With energy as the basis of its development, Nexans, the worldwide
More informationLT/HT Power & Control Cables
LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationXLPE Land Cable Systems User s Guide. Rev 5
XLPE Land Cable Systems User s Guide Rev 5 CONTENT XLPE Land Cable Systems Introduction... 3 Design, installation and testing... 4 XLPE cables... 4 Cable accessories... 4 Installation of XLPE cable systems...
More informationTECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E/TS
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationQuality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
More informationCable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks
Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt
More informationTECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara 390 007 TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GETCO/E/TS PCBL025/RO DT.07-03-2008
More informationHigh Voltage Cable Systems
High Voltage Cable Systems Cables and Accessories up to 550 kv Completing the picture nkt cables part of a world, counting on reliable and available electrical power Today a world without electrical power
More information4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationCURRENT RATINGS MORE THAN A CABLE
CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationTechnical cable guide
Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now
More informationTECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E /TS
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: ECS 02-0019 ENGINEERING CONSTRUCTION STANDARD ECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV
More informationHIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationFLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS
Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL
More informationOffshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationHow To Monitor Water Penetration In A Cable Screen
Detection and location of high voltage cable sheath damage with Water Penetration Monitoring*) Purpose of Monitoring System The expected lifetime of high voltage underground cables is more than 40 years,
More informationXLPE рower cables. 2 Modern solutions for power cables I Estralin HVC
XLPE рower cables...2 Production technology...3 Estralin HVC a pioneer in Russia s XLPE cable production...4 Main types of products and services...5 Markings...6 XLPE cables 6-35 kv...7 Comparative characteristics
More informationZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES SUBMARINE CABLE CO., LTD
ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES SUBMARINE CABLE CO., LTD Brief Introduction Zhongtian Technologies Submarine Co., Ltd. is a subsidiary of nation-important-tech enterprise Zhongtian
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationOPTICAL FIBER CABLES
OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL
More informationThe Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
More informationCable Size Selection for Energy Efficiency
Cable Size Selection for Energy Efficiency Introduction The traditional method for determining the appropriate cable size for a particular installation involves the selection of the smallest size conductor
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
More informationCHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES
AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationSizing conductors and selecting protection devices
Sizing conductors and selecting protection devices 04 PowEr guide 2009 / BOOk 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will
More informationCatalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationSnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES
SnoTrace Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace INSTALLATION PROCEDURES Refer to the SnoTrace Cable Testing Report for required recording of test data and circuit information. Upon
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More information144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION
Fiber Single Mode Optical Fibre 144 Nos. Sterlite Fiber ITU.T - G.652 D Maximum Cabled Fibre Attenuation db/km 1310nm : 0.36 & 1550nm : 0.23 Loose Tube Filling Jelly Fiber/Tube 24 Nos. Thixotropic jelly
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationCable Installation Notes
Cable Installation Notes June 2006 Table of Contents Cable Pulling... 2 Bending Radius... 2 Pulling Tension... 3 Friction... 3 Installation with Rollers... 4 Installation without Rollers... 4 Pulling Tension
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationMedium Voltage Power Cables
Works photo: HELUKABEL Medium Voltage Power Cables Medium Voltage Power Cables Medium Voltage Power Cables up to 30 kv with XLPE-insulation The XLPE-insulation possesses very good electrical, mechanical
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationGOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.
GOWN Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOWN102
More informationPower Cable Catalogue
2012 EDITION www.olex.co.nz HEAD OFFICE 69 Paraite Road Bell Block New Plymouth New Zealand PHONE 0800 OLEX NZ AUCKLAND BRANCH 105 Hugo Johnston Drive Penrose Auckland 1061 New Zealand EMAIL technical.olexnz@nexans.com
More informationEnhanced Quality with a Touch of Style
Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying
More information)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3
More informationDrop cables. Vorstadt 32 CH, 6304 Zug Switzerland. teletronik@teletronik.com www.teletronik.com
Drop cables Vorstadt 32 CH, 6304 Zug Switzerland AG teletronik@teletronik.com www.teletronik.com Brief Introduction Teletronik RG series coaxial cable was developed to meet the increasing demand of tomorrow's
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationTemperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationFibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
More information