1 FEDERAL POWER TM PRODUCT CATALOG X L P E XLPE Insulated Power Cables Federal Power Sdn Bhd ( V) Lot 8, Jln Ragum 15/17, P.O.Box Shah Alam, Selangor West Malaysia Tel (603) /601/602 Fax (603) (603) Website: / coercial@federalpower.com.my Designed by : Information Systems Dept

2 CONSTRUCTION 600/1000V XLPE/PVC Power Cable Insulation Fillers Binder tape Outer sheath 3.6/6-18/30 kv XLPE/PVC Power Cable shelding (Semi-conducting layer) Insulation Insulation shielding (Semi-conducting layer) Metallic shielding Fillers Binder tape Outer sheath Single core Three core 600/1000V XLPE/SWA/PVC Power Cable 3.6/6-18/30 kv XLPE/SWA/PVC Power Cable Insulation Fillers Binder tape Separation sheath Steel wire armour Outer sheath shielding (Semi-conducting layer) Insulation Insulation shielding (Semi-conducting layer) Metallic shielding Fillers Binder tape Separate sheath Steel wire armour Outer sheath Notes: SWA : Steel wire armoured 1

3 CONSTRUCTION 11kV up to 33kV AI-XLPE/SWA/PE Cable ; Hard drawn aluminium shielding Insulation: XLPE Insulation shielding Metallic shielding: Copper tape Fillers Binder tape Bedding: Black polyethylene Armour : Galvanized steel wire Outer sheath: Black polyethylene 11kV up to 33kV AI-XLPE/PE Aerial Cable shielding Insulation Insulation shielding Metallic shielding Binder tape Sheath: Black HDPE Messenger wire : Galvanized steel wire 2

4 CONSTRUCTION Cross-section 600/1000 V AI-XLPE/SWA/PE Cable : Hard drawn aluminium, sector shape Insulation: XLPE Fillers: Polypropylene yarn Binder tape: Plastic tape Bedding: Black polyethylene Armour: Galvanized steel wire Outer sheath: Black-termite repellent polyethylene Core identification : Core identification shall be made by coloured insulation compound. Cable identification : Outer sheath shall be embossed. Cross-section 11 kv up to 33 kv AI-XLPE/PE Aerial Cable : Hard drawn aluminium shielding Insulation : XLPE Insulation shielding: Metallic shielding: Annealed copper tape Sheath: Black HDPE Messenger wire: Galvanized steel wire Cross-section 11 kv up to 33 kv AI-XLPE/SWA/PE Cable : Hard drawn aluminium shielding Insulation: XLPE Insulation shielding Metallic shielding Fillers: Polypropylene yarn Binder tape Bedding: Black polyethylene Armour: Galvanized steel wire Binder tape Outer Sheath: Black termite repellent polyethylene 3

5 11kV up to 161kV XLPE/PE Cable with Copper wire screen CONDUCTOR (Copper or aluminium) CONDUCTOR SHIELD INSULATION (XLPE) INSULATION SHIELD SWELLABLE TAPE METALLIC SCREEN (Copper wires) BINDING TAPE OUTER SHEATH 4

6 11kV up to 132kV XLPE/LC/PE or PVC with lead sheathed CONDUCTOR (Copper or aluminium) CONDUCTOR SHIELD INSULATION (XLPE) INSULATION SHIELD LEAD SHEATH OUTER SHEATH 5

7 11kV up to 132kV XLPE/AWA/PE or PVC with Aluminium wire screen CONDUCTOR (Copper or aluminium) CONDUCTOR SHIELD INSULATION (XLPE) INSULATION SHIELD SWELLABLE TAPE METALLIC SCREEN (Aluminium wires) BINDING TAPE OUTER SHEATH 6

8 Technical Data CONTINUOUS CURRENT CARRYING CAPACITY The tabulated current rating have been calculated in accordance with IEC 287. They are for single circuit with the standard conditions as follow:- i) Maximum permissable conductor temperature at continuous operation is 90 deg. C ii) Ground temperature is 25 deg.c iii) Ambient temperature is 40 deg.c iv) Ground thermal resistivity is 1.2 Km/W v) Cables laying depth is ground:- - s voltage up to 1kV s voltage above 1kv 800 vi) Spacing between s:- -In flat formation.2 times the. -In trefoil formation.s touching. vii) Cable s sheath or armour solidly bonded at both ends viii) Cables shielded from direct sun rays For conditions operation different from those on which the continuous current carrying capacity tables are based, ratings can be determined by application Rating Factor in table below. Rating Factor Rating Factor For Cables In Air Ambient air temperature Rating Factor Rating Factor For Ground Temperature Ground temperature Rating Factor Rating Factor For Thermal Resistivity Ground size (2) Thermal Resistivity (K.m/W) Single Core Cable Up to 150 From 185 to 400 From 500 to Multicore s Up to 16 From 25 to 150 From 185 to Depth laying (m) Rating Factor For Depth Laying 0.6 / 1 kv s 1.9 / 3.3 kv to 19 / 33 kv s up to to 300m2 above 3002 up to 3002 above or more

9 Group Derating Factors Derating Factors for groups s installed in air Multiple circuits Number vertically 1 2 Number horizontally Spacing S = d S = 2d S = 3d Number vertically 3 Number s horizontally N/A Spacing S = d S = d2 S = 3d Number s horizontally Number vertically + + S + + S + + d S Derating Factors for groups s laid direct in ground Cable Voltage (kv) 0.6/1 1.9/3.3 to 12.7/22 19/33 Number circuit Trefoil Touching Laid flat * This spacing will not be possible for some the larger s. Three single core s in trefoil and laid flat touching, horizontal formation Spacing circuit (between centres s groups) 0.15m* 0.3m 0.45m 0.6m Derating Factors for groups s laid direct in ground Multicore s in horizontal formation Cable Voltage (kv) Number Of circuits Spacing circuits (between centres groups) Touching 0.15m* 0.3m 0.45m 0.6m 0.6/1 1.9/3.3 to 12.7/ / * This spacing will not be possible for some the larger s. 8

10 Handling and installation XLPE 1. Minimum bending radius and permissible maximum pulling tension. For safety installation without damaging electrical and physical properties, the following minimum bending radius and permissible maximum pulling tension must be observed. Minimum bending radius D: Overall dia. Of Type Number core Round conductor Single core Four segmental stranded conductor Multi core 600 V 10D 12D 8D 3,300 V and higher 10D 12D 8D Triplex type - - 8D Corrugated metal armoured 10D 12D 8D Flat tape armoured 10D 12D 8D Wire armoured 10D 12D 10D Lead sheathed 10D 12D 10D Permissble maximum pulling tension Pulling tool Material conductor Permissible maximum pulling tension (kg) Pulling eye Copper 7 x (Number core) x (Core-sectional area conductor) Aluminium 4 x (Number core) x (Core-sectional area conductor) Cable grip Copper & aluminium The same as using the pulling eye, but the minimum tension should be less than two tons Note : When grip is used it should cover more than 500 in length end be bound to the sheath. 2. Side wall pressure to 3. Removal sheath or tape Special care must be taken not to harm the insulation Permissible maximum side wall pressure to the at when removing the sheath or tapes with knife otherwise bending point during installation is 500 kg/m. it may results in a dielectric breakdown. Note : pulling tension (kg) = T 4. Cleaning the surface insulation Side wall pressure to The surface insulation should be cleaned to avoid a bending radius (m) R flash over at the termination or joint. T : Pulling tension (kg) R : Bending Radius (m) R 5. Applying self-adhesive tape When applying a self-adhesive tape after joint or terminating XLPE, stretch it properly about 1.2 times as long as the original one. If it is over-stretched crack may occur on the tape will not be adhered between each layer. 6. Water pro treatment for out-door termination For out-door termination water pro treatment is necessary to avoid the water penetrating into the end and special care must be taken to apply tapes and terminals. It is desirable to use a compression to solder type terminal. Side wall pressure T 9

11 DIMENSIONAL TABLE XLPE / PE or PVC For Aluminium and Copper 600/1000 V XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Nominal Shape thickness Approximate cross sectional weight weight area sheath sheath (Cu) (AL) sq kg/km kg/km Compact round stranded /1000V Multi-core XLPE/PE Power Cable, Type XLPE/PE Nominal Three core Four core Cross Approx sectional Shape weight weight weight weight area insulation sheath (copper) (alu) sheath (copper) (alu) sq kg/km kg/km kg/km kg/km Compact round stranded

12 DIMENSIONAL ` TABLE, XLPE / PE or PVC 0.6/1 kv-xlpe/pe.lv-continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Core 4 Core 4 Core 4 Core 4 Core 4 Core 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)

13 DIMENSIONAL TABLE, XLPE / PE or PVC 1.9/3.3 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded /6.6 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded

14 DIMENSIONAL TABLE XLPE / PE or PVC 3.6/6 kv XLPE/PE.MV-Continuous Current Rating Factor (100%-Load) Condu- in-air at 40 0 C in-ground at 30 0 C in-duct conductor ctor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)

15 DIMENSIONAL TABLE, XLPE / PE or PVC 6.35/11 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded /15kV XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded

16 DIMENSIONAL TABLE, XLPE / PE or PVC 12.7/22 kv XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded /33kV XLPE/PE Power Cable, Type XLPE/PE Nominal Single core Three core cross thickness Approx sectional Shape weight weight weight weight area insulation sheath (Cu) (AL.) sheath (Cu) (AL.) sq kg/km kg/km kg/km kg/km Compact round stranded

17 DIMENSIONAL TABLE, XLPE / PE or PVC 6.35/11kV to 19/33 kv-xlpe/pe.mv-continuous Current Rating Factor (100%-Load) in-air at 40 0 C in-ground at 30 0 C in-duct conductor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)

18 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE For Aluminium and Copper 600/1000 V Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded

19 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 0.6/1 Kv-XLPE/SWA/PE or PVC.LV-Continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Core 4 Core 4 Core 4 Core 4 Core 4 Core 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)

20 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 1.9/3.3 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded /6.6 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded

21 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 3.6/6 kv XLPE/SWA/PE or PVC MV-Continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)

22 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 6.35/11 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded /15 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded

23 DIMENSIONAL TABLE, XLPE / SWA/PVC or PE 12.7/ 22 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded /33 kv Three Core XLPE/SWA/PVC, Steel Wire Armoured Power, Type XLPE/SWA/PVC Nominal Nominal Shape thickness weight weight cross separation under armour outer (Cu) (AL.) sectional insulation sheath wire wire sheath area sq kg/km kg/km Compact round stranded

24 DIMENSIONAL 1 TABLE, XLPE / SWA/PVC or PE 6.35/11 19/33 kv-xlpe/swa/pe.mv or PVC-Continuous Current Rating Factor (100%-Load) Conduc- in-air at 40 0 C in-ground at 30 0 C in-duct conductor tor Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Size Single or Single or Single or Single or Single or Single or 1 Sec. 1 Sec. Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Isolated 4 Core Core Core Core Core Core fault fault Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable Flat Trefoil Cable current current (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (ka) (ka)

25 DIMENSIONAL TABLE, Copper, XLPE / CWS/PE or PVC 38/66 kv XLPE INSULATED POWER CABLE Copper, XLPE/CWS/PE or PVC Nominal Outside thickness Shape jacket size insulation () (2) ) () ) Weight (kg/km) DC resistance (Ω /km) Electrostatic capacity (µf/km) Compact Round Stranded Four 1000 Segmental Stranded Aluminium conductor,xlpe/pe or PVC Nominal Outside thickness Shape jacket size insulation () (2) ) () ) Weight (kg/km) DC resistance (Ω /km) Electrostatic capacity (µf/km) Compact Round Stranded Four 1000 Segmental Stranded

26 DIMENSIONAL TABLE, XLPE / CWS/ PE or PVC 76/132kV XLPE Insulated Power Cable with Copper Wire screen Aluminium, XLPE/CWS/PE or PVC size (2) Shape ) Nominal thickness insulation () jacket () Outside ) Weight (kg/km) DC resistance (Ω /km) Electrostatic capacity (µf/km) Compact Round Stranded Four 1000 Segmental Stranded Continuous current ratings (load factor = 100%) In ground In air In duct Size (2) Trefoil Flat Trefoil Flat Trefoil Flat (A) (A) (A) (A) (A) (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Aluminium cond

27 DIMENSIONAL TABLE, XLPE / CWS/ PE or PVC 76/132kV XLPE Insulated Power Cable with Copper wire screen Copper conductor, XLPE/CWS/PE or PVC size (2) Shape ) Nominal thickness insulation () jacket () Outside ) Weight (kg/km) DC resistance ( Ω/km) `Electrostatic capacity (µ F/km) Compact Round Stranded Four 1000 Segmental Stranded Continuous current ratings (load factor = 100%) In ground In air In duct Size (2) Trefoil Flat Trefoil Flat Trefoil Flat (A) (A) (A) (A) (A) (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond

28 DIMENSIONAL TABLE XLPE/PE or PVC 93/161 kv XLPE insulated Power Cable with Copper wire screen. Copper, XLPE/PE or PVC size (²) Shape ) Nominal thickness insulation () jacket () Outside ) Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Continuous current ratings (load factor = 100%) Size (²) Trefoil (A) In ground In air In duct Flat (A) Trefoil (A) Flat (A) Trefoil (A) Flat (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond

29 DIMENSIONAL TABLE XLPE/LC/PE or PVC 38/66 kv Lead Sheathed Cable Copper, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Continuous current ratings (load factor = 100%) Size (²) Trefoil (A) In ground In air In duct Flat (A) Trefoil (A) Flat (A) Trefoil (A) Flat (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond

30 DIMENSIONAL TABLE XLPE/PE or PVC 38/66 kv XLPE Insulated Lead Sheathed Cable Aluminium conductor, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Continuous current ratings (load factor = 100%) In ground In air In duct Size (²) Trefoil (A) Flat (A) Trefoil (A) Flat (A) Trefoil (A) Flat (A) 1 sec Fault current rating (ka) 3 sec Fault current rating (ka) Copper cond

31 DIMENSIONAL TABLE XLPE/PE or PVC 76/132 kv XLPE Insulated Lead Sheathed Cable Copper conductor, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded Aluminium conductor, XLPE/LC/PE or PVC size (²) Shape () Nominal thickness insulation () jacket () lead sheathed () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded Four Segmental Stranded

32 DIMENSIONAL TABLE XLPE/PE or PVC 38/66 kv XLPE Insulated Power Cable Aluminium Wire Screen Copper conductor, XLPE/ AWA /PE or PVC size (²) Shape ) Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x Aluminium conductor, XLPE/ AWA / PE or PVC size (²) Shape () Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x

33 DIMENSIONAL TABLE XLPE/PE or PVC 63/132 kv XLPE Insulated Power Cable with Aluminium Wire Screen Copper conductor, XLPE/ AWA /PE or PVC size (²) Shape () Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x Aluminium conductor, XLPE/ AWA / PE or PVC size (²) Shape ) Nominal thickness insulation () & number aluminium wire ( x N) jacket () Outside Weight (kg/km) DC resistance (Ω/km) Electro-static capacity (µf/km) Compact Round Stranded x x x x x Four Segmental Stranded x x

34 Some Of The Various Utility Specified Cables 600/1000 V Four Core XLPE/SWA/PVC, Steel Wire Armoured Power Cable, Type XLPE/SWA/PVC Cross sectional area sq Shape Nominal thickness insulation separation sheath under wire armour wire outer sheath weight (Cu) kg/km weight (AL) kg/km Compact round stranded /11kV Three Core XLPE/SWA/PVC, Steel Wire Armoured Power Cable, Type XLPE/SWA/PVC Cross sectional area sq Shape Nominal thickness insulation separation sheath under wire armour wire outer sheath weight (Cu) kg/km weight (AL) kg/km Compact round stranded /33 kv Three Core XLPE/SWA/PVC, Wire Armoured Power Cable, Type XLPE/SWA/PVC Cross sectional area sq Shape Nominal thickness insulation separation sheath under wire armour wire outer sheath weight (Cu) kg/km weight (AL) kg/km Compact round stranded

35 Some Of The Various Utility Specified Cables 600/1000 V Four Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Cross sectional area sq 25 Shape thickness insulation separation sheath lead sheath separation sheath Approx under armour armour wire outer sheath 95 Compact round stranded Approx weight (Cu) /11 kv Three Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx thickness Cross Shape separation lead separation armour sectional under insulation sheath sheath sheath wire area armour sq 25 outer sheath Compact round stranded /33 kv Three Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx Nominal thickness Cross Shape separation lead separation armour sectional under insulation sheath sheath sheath wire area armour sq 25 outer sheath Compact round stranded kg/km Approx weight (Cu) kg/km Approx weight (Cu) kg/km weight (AL.) kg/km weight (AL.) kg/km weight (AL.) kg/km 34

36 Some Of The Various Utility Specified Cables 6.35/11 kv Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC cross sectional area sq 25 Shape thickness insulation separation sheath lead sheath separation sheath Approx under armour armour wire outer sheath 150 Compact round stranded Approx weight (Cu) kg/km weight (AL.) kg/km 12.7/22 kv Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx thickness cross separation lead separation armour outer sectional Shape under insulation sheath sheath sheath wire sheath area armour sq Compact round 240 stranded Approx weight (Cu) kg/km weight (AL.) kg/km 19/33 kv Single Core XLPE/LC/SWA/PVC, Wire Armoured,Lead Covered Power Cable, Type XLPE/LC/SWA/PVC Approx thickness cross separation lead separation armour outer sectional Shape under insulation sheath sheath sheath wire sheath area armour sq Compact round stranded Approx weight (Cu) kg/km weight (AL.) kg/km 35

CONFLEX ELECTRIC CABLE

CONFLEX ELECTRIC CABLE CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC

More information

EDS 02-0027 11KV TRIPLEX CABLE

EDS 02-0027 11KV TRIPLEX CABLE THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:

More information

Cables, Cable Laying & Accessories Manual

Cables, Cable Laying & Accessories Manual Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

MEDIUM VOLTAGE CABLES Up to and including 36 KV

MEDIUM VOLTAGE CABLES Up to and including 36 KV MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types

More information

High Voltage Systems. Today. The history of cables

High Voltage Systems. Today. The history of cables High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,

More information

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO. SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables

More information

MEDIUM VOLTAGE POWER CABLES

MEDIUM VOLTAGE POWER CABLES MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35 CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature

More information

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Specializing in the cable business for over 38 years, PT. SUPREME CABLE Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international

More information

MV CABLE TYPE C 33-226

MV CABLE TYPE C 33-226 MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation

More information

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY

More information

Power and Wiring Cables

Power and Wiring Cables 1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................

More information

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69 Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

LOW VOLTAGE POWER CABLES

LOW VOLTAGE POWER CABLES LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED

More information

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum

More information

Removal of EP 20 10 00 02 SP High Voltage Cable

Removal of EP 20 10 00 02 SP High Voltage Cable TN 018: 2014 Technical Note For queries regarding this document standards@asa.transport.nsw.gov.au www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:

More information

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying

More information

HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide

HIGH VOLTAGE XLPE CABLE SYSTEMS. Technical User Guide HIGH VOLTAGE XLPE CABLE SYSTEMS Technical User Guide Content 1. General information on High Voltage XLPE Cable Systems 1.1. Introduction 1.2. Cable selection process 1.3. Service life 3 3 3 4 2. Cable

More information

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables 6-36kV Medium Voltage Underground Power Cables XLPE insulated cables Cable solutions to ensure the reliability of your energy network 2 With energy as the basis of its development, Nexans, the worldwide

More information

LT/HT Power & Control Cables

LT/HT Power & Control Cables LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

APPLICATION ORIENTED DESIGN OF CABLES

APPLICATION ORIENTED DESIGN OF CABLES APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com

More information

XLPE Land Cable Systems User s Guide. Rev 5

XLPE Land Cable Systems User s Guide. Rev 5 XLPE Land Cable Systems User s Guide Rev 5 CONTENT XLPE Land Cable Systems Introduction... 3 Design, installation and testing... 4 XLPE cables... 4 Cable accessories... 4 Installation of XLPE cable systems...

More information

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E/TS

More information

Industrial Cable Solutions for Variable Frequency Drives

Industrial Cable Solutions for Variable Frequency Drives Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading

More information

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM

More information

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING

More information

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS: PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2

More information

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt

More information

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION

TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara 390 007 TECHNICAL SPECIFICATION OF 11 / 22 KV XLPE POWER CABLE FOR SUB-STATION GETCO/E/TS PCBL025/RO DT.07-03-2008

More information

High Voltage Cable Systems

High Voltage Cable Systems High Voltage Cable Systems Cables and Accessories up to 550 kv Completing the picture nkt cables part of a world, counting on reliable and available electrical power Today a world without electrical power

More information

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters 8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article

More information

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN

PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

CURRENT RATINGS MORE THAN A CABLE

CURRENT RATINGS MORE THAN A CABLE CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:

More information

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase

More information

Technical cable guide

Technical cable guide Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now

More information

TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS OF 66 KV 1C 300 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE GETCO/E /TS

More information

Outside Telephone Cable

Outside Telephone Cable Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of

More information

ECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

ECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: ECS 02-0019 ENGINEERING CONSTRUCTION STANDARD ECS 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

More information

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec

More information

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

6 ELECTRICAL PARAMETERS

6 ELECTRICAL PARAMETERS 6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities

More information

Commercial Coaxial Cable

Commercial Coaxial Cable Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of

More information

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL

More information

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -

More information

The Quality Connection. BETAflam Fire Resistant Safety Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

How To Monitor Water Penetration In A Cable Screen

How To Monitor Water Penetration In A Cable Screen Detection and location of high voltage cable sheath damage with Water Penetration Monitoring*) Purpose of Monitoring System The expected lifetime of high voltage underground cables is more than 40 years,

More information

XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC

XLPE рower cables. 2 Modern solutions for power cables I Estralin HVC XLPE рower cables...2 Production technology...3 Estralin HVC a pioneer in Russia s XLPE cable production...4 Main types of products and services...5 Markings...6 XLPE cables 6-35 kv...7 Comparative characteristics

More information

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES SUBMARINE CABLE CO., LTD

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES SUBMARINE CABLE CO., LTD ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES SUBMARINE CABLE CO., LTD Brief Introduction Zhongtian Technologies Submarine Co., Ltd. is a subsidiary of nation-important-tech enterprise Zhongtian

More information

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

OPTICAL FIBER CABLES

OPTICAL FIBER CABLES OPTICAL FIBER CABLES CONTENTS INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING PARAMETERS GENERALITIES :. Advantage. General Description.. Construction.. Principle TYPICAL SPECIFICATIONS OF OPTICAL

More information

The Handbook 2013 EDITION

The Handbook 2013 EDITION The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,

More information

Cable Size Selection for Energy Efficiency

Cable Size Selection for Energy Efficiency Cable Size Selection for Energy Efficiency Introduction The traditional method for determining the appropriate cable size for a particular installation involves the selection of the smallest size conductor

More information

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install

More information

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission

More information

Fire Resistant Cables

Fire Resistant Cables 109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data

More information

COAX Cables Radio Frequency Cables

COAX Cables Radio Frequency Cables COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions

More information

Sizing conductors and selecting protection devices

Sizing conductors and selecting protection devices Sizing conductors and selecting protection devices 04 PowEr guide 2009 / BOOk 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will

More information

Catalogue Câbles d Energie

Catalogue Câbles d Energie Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie

More information

100% EMI Emission Containment

100% EMI Emission Containment 100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive

More information

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace INSTALLATION PROCEDURES Refer to the SnoTrace Cable Testing Report for required recording of test data and circuit information. Upon

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION Fiber Single Mode Optical Fibre 144 Nos. Sterlite Fiber ITU.T - G.652 D Maximum Cabled Fibre Attenuation db/km 1310nm : 0.36 & 1550nm : 0.23 Loose Tube Filling Jelly Fiber/Tube 24 Nos. Thixotropic jelly

More information

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness 450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number

More information

Cable Installation Notes

Cable Installation Notes Cable Installation Notes June 2006 Table of Contents Cable Pulling... 2 Bending Radius... 2 Pulling Tension... 3 Friction... 3 Installation with Rollers... 4 Installation without Rollers... 4 Pulling Tension

More information

Flexible Control Cables

Flexible Control Cables Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport

More information

CAVEL VS80205 MADE IN ITALY 1000 V

CAVEL VS80205 MADE IN ITALY 1000 V 0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored

More information

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification

More information

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for

More information

Medium Voltage Power Cables

Medium Voltage Power Cables Works photo: HELUKABEL Medium Voltage Power Cables Medium Voltage Power Cables Medium Voltage Power Cables up to 30 kv with XLPE-insulation The XLPE-insulation possesses very good electrical, mechanical

More information

MICROCABLES. A complete vision of your connectivity needs. Catalogue

MICROCABLES. A complete vision of your connectivity needs. Catalogue MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics

More information

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information. GOWN Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOWN102

More information

Power Cable Catalogue

Power Cable Catalogue 2012 EDITION www.olex.co.nz HEAD OFFICE 69 Paraite Road Bell Block New Plymouth New Zealand PHONE 0800 OLEX NZ AUCKLAND BRANCH 105 Hugo Johnston Drive Penrose Auckland 1061 New Zealand EMAIL technical.olexnz@nexans.com

More information

Enhanced Quality with a Touch of Style

Enhanced Quality with a Touch of Style Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying

More information

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

)454, !,5-).)5- #!,% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!,%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation, INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3

More information

Drop cables. Vorstadt 32 CH, 6304 Zug Switzerland. teletronik@teletronik.com www.teletronik.com

Drop cables. Vorstadt 32 CH, 6304 Zug Switzerland. teletronik@teletronik.com www.teletronik.com Drop cables Vorstadt 32 CH, 6304 Zug Switzerland AG teletronik@teletronik.com www.teletronik.com Brief Introduction Teletronik RG series coaxial cable was developed to meet the increasing demand of tomorrow's

More information

Festoon 715 P PUR cable for flexible application in festoon systems

Festoon 715 P PUR cable for flexible application in festoon systems CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance

More information

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to

More information

Fibre optic cables MDIC LSZH

Fibre optic cables MDIC LSZH MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy

More information