EPS Electric Power System
|
|
- Dina Rice
- 7 years ago
- Views:
Transcription
1 EPS Electric Power System The newest generation of built-in generators.
2 Rosenbauer EPS Electric Power System EPS Electric Power System. Unique. Flexible. Powerful. The Rosenbauer Electric Power System is the modern answer to the problem of more electrical power on the fire fighting truck. Rosenbauer offers the new EPS XS for installation near the engine and belt drive with power of up to 11 kva as well as the EPX XL with cardan shaft drive from the PTO of the chassis with power of up to 90 kva. Both systems enable new applications for supplying electricity to devices in use. Benefits of the EPS Electric Power System. Direct, lossless, and variable speed drive of the generator Largely maintenance-free system due to the direct drive of the generator Parallel operation of pump and generator with high load at EPS XL possible Versatile applications (all electrical devices) Freedom of positioning of the devices on the vehicle Simple retrofitting of devices Operation via LCS display Satisfies DIN (EPS XL) and DIN 14687, supplemented by 400V (EPS XS) High safety through permanent insulation monitoring and IT network configuration An individual solution for you. The modular system comprised of a generator, converter, and electrical consumers is easily adapted to the needs of each customer and thus to each vehicle category. The overall system including safety devices is designed according to current standards. The system components such as generators and the converters adapted to this purpose were developed in close partnership with renowned specialists, only Rosenbauer has access to these components. 2
3 EPS XL Power up to 90 kva The EPS XL system is a high-performance generator system as an alternative to conventional built-in generators and large mobile units. It serves for the electrical drive of all consumers in the fire fighting truck with the exception of the centrifugal pump. Installation in the vehicle The power generator with integrated rectifier is built into the chassis frame and driven directly by a PTO of the chassis by way of a cardan shaft. The converter and control box are flexibly positioned in the body. Additional sockets are flexibly installed in the body depending on the requirements. Sizes from 16 to 63 A are possible. Technical data Design Electrical power (at maximum power generator speed > 3,000 1/min) Compliance with standards Artificial mains network 60 kva Artificial mains network 80 kva Engine drive 30 kva Artificial mains network continuous output Pel, 3~ = 60 kva / cos ϕ = 0.8 / 48 kw Pel, 3~ = 80 kva / cos ϕ = 0.8 / 64 kw DIN electric switchboard DIN V AC, 50 Hz L1 L2 L3 N NP autotransformer DIGIMATIC 48 (incl. inverter) CONTI CAFS 30E compressor 400 V AC, 50 Hz L1 L2 L3 DC / AC inverter 60 kva or 80 kva DIGIMATIC 48 (incl. inverter) DC / AC inverter 30 kva DC engine generator insulation monitor 600 VDC Diagram: EPS Electric Power System 3
4 EPS Electric Power System Rosenbauer EPS XS Power up to 11 kva With the EPS XS, it is possible for the first time to produce three-phase 400 V AC voltage in a fire fighting truck by way of a direct motor using the power generator installed in the engine compartment. In contrast to conventional single-phase 230V systems, all heavy devices, such as submersible pumps, contaminated water pumps, etc. can be driven directly. Installation in the engine compartment The EPS XS generator is built directly into the engine compartment of the vehicle and driven by a belt. The converter and control box are flexibly positioned in the body. The position of the sockets can be selected according to the vehicle load. Technical data Design Electrical power (at maximum power generator speed of 6,000 1/min) Compliance with standards Artificial mains network 11 kva Short-term superior performance Pel, 3~ = 11.2 kva / cos ϕ = 0.8 / 9.0 kw Continuous output Pel, 3~ = 9.3 kva / cos ϕ = 0.8 / 7.5 kw DIN 14687, supplemented by the 400 V range engine electric switchboard DIN (for 400 V) Tried and tested technology The technology of the EPS XS equals that of the EPS XL system 1:1. Rosenbauer has many years of experience as the only manufacturer of such technology in the fire fighting industry. generator 400 V AC, 50 Hz 400 V AC, Hz inverter, insulation monitor, autotransformer 4
5 EPS Electric Power System Rosenbauer Applications... more light Electricity is the most flexible source of energy. Electricity offers the widest variety of possible uses, whereby completely new applications emerge.... more pump output... more feed pumping... more consumers... more compressed air foam... more foam... more emergency power supply... more decontamination 5
6 EPS The newest generation of built-in generators. Fire brigade Aschheim / Germany EPS XL 52 kva, DIGIDOS 36 Fire brigade Rottach-Egern / Germany EPS XL 80 kva, hydraulic winch Fire brigade Günzburg / Germany EPS XL 60 kva Fire brigade Busan / South Korea EPS XL 60 kva, CONTICAFS 30E with SkyCAFS Airport Genf / Switzerland EPS XL 60 kva, 2x DIGIMATIC 48, hydraulic winch Hong Kong Fire Service Department EPS XL 60 kva, DIGIMATIC 48, CONTICAFS 30E Text and images non-binding. The images may depict special editions that are only available at an additional charge. Subject to change due to technical advances. VI0421/EPS_EN_2015_05_ References
N/NH Truck-mounted fire pump series
N/NH Truck-mounted fire pump series Normal pressure pump type N Combined normal- and high-pressure fire pump type NH Certified according to EN 1028 and UL classified Rosenbauer - N/NH Truck-mounted fire
More informationSAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content
More informationFigure. 1 - Split Phase 240/120V circuit (180 phase shift)
This technical note describes the option of connecting the 60Hz XW Inverter/Charger to a three-phase source by using a transformer to convert the AC source to split-phase 240/120V. INTRODUCTION: Split-phase
More informationELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION
ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION SC ELECTROPUTERE SA SC ELECTROPUTERE SA 1. Vision, Mission, Values SC ELECTROPUTERE SA 2. LOCATION Craiova: Located in the South West of the country,
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview
ENERGY-SAVINg DRIVE PACKAGE SPriPM Motor & YASKAWA V1000 Inverter Drive EN DE ES FR IT Overview - Super Premium IPM Motor & YASKAWA V1000 Inverter Drive The Motor-Inverter Package was developed to support
More informationApplication of a Large Hybrid Turbocharger for Marine Electric-power Generation
29 Application of a Large Hybrid Turbocharger for Marine Electric-power Generation YOSHIHISA ONO *1 KEIICHI SHIRAISHI *2 YUKIO YAMASHITA *3 The function of our new marine hybrid turbocharger, which has
More informationVariable Frequency Drives - a Comparison of VSI versus LCI Systems
Variable Frequency Drives - a Comparison of VSI versus LCI Systems Introduction TMEIC is a leader in the innovative design and manufacture of large ac variable f requency drive systems. TMEIC has been
More informationEnergy Savings through Electric-assist Turbocharger for Marine Diesel Engines
36 Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines KEIICHI SHIRAISHI *1 YOSHIHISA ONO *2 YUKIO YAMASHITA *3 MUSASHI SAKAMOTO *3 The extremely slow steaming of ships has become
More informationELECTRONIC POWER SYSTEMS
ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1 Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While
More informationvacon ac drives for mining & minerals
vacon ac drives for mining & minerals 1 strong experience in mining & minerals Vacon AC drives are robust to handle your most demanding requirements from simple ventilation to the most complex load sharing
More informationUnderstanding Delta Conversion Online "Power Regulation" - Part 2
Application Note #40 Understanding Delta Conversion Online "Power Regulation" - Part 2 Introduction This application note is the second in a series on delta conversion theory of operation. For complete
More informationData Sheet. AC Industrial Electric Motors
Data Pack B Issued ovember 2005 1502325812 Data Sheet AC Industrial Electric Motors Standards organisations The RS-ABB range of ac induction motors is produced to common European standards, these being
More informationUNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES
UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)
More informationPower transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
More informationElectric Power in Airplane. Student: Maja Knezev Course ELEN 615, 31 st August 2006
Electric Power in Airplane Student: Maja Knezev Course ELEN 615, 31 st August 2006 Power sources on aircraft engine driven AC generators, auxiliary power units (APUs), external power and ram air turbines.
More informationDRAIN PUMPS. Synchronous Drain Pumps DPS / DPO
DRAIN PUMPS Synchronous Drain Pumps DPS / DPO moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for almost every application
More informationAPPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.
USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS Abstract This application note describes the necessary procedure to use a standard Pacific Power Source Model
More informationIncreasing Data Center Efficiency by Using Improved High Density Power Distribution
Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations
More informationWhat Is Regeneration?
What Is Regeneration? Braking / Regeneration Manual Regeneration Overview Revision 1.0 When the rotor of an induction motor turns slower than the speed set by the applied frequency, the motor is transforming
More informationSeries description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
More informationKINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE
ADVANCED ENGINEERING 3(2009)1, ISSN 1846-5900 KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE Cibulka, J. Abstract: This paper deals with the design of Kinetic Energy Recovery Systems
More informationVariable Frequency Drives and Energy Savings
Variable Frequency Drives and Energy Savings It s more than just fan and pump applications www.sea.siemens.com by: Stephen Prachyl www.usa.siemens.com/energysavings When discussing energy savings and variable
More informationPRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS
D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for
More informationPLM series Permanent load lifting magnets
Lifting gear Load lifting magnets/chain hoists PLM series Permanent load lifting magnets Load-bearing capacity of up to 1 t depending on model despite light weight High standard of safety with simple lever
More informationElectric Coolant Pumps. Always at the Correct Temperature
Electric Coolant Pumps Always at the Correct Temperature Electric coolant pumps Conventional pumps for engine cooling are driven by toothed belts and hence their output is coupled to engine RPM. Coolant
More informationDevelopment of Power Supply System with Hybrid Turbocharger for Marine Application
JFE TECHNICAL REPORT No. 19 (Mar. 2014) Development of Power Supply System with Hybrid Turbocharger for Marine Application SUTO Naonori*1 MINAMI Hiroki*2 Abstract: Hybrid turbocharger is a turbocharger
More information3-Phase AC Calculations Revisited
AN110 Dataforth Corporation Page 1 of 6 DID YOU KNOW? Nikola Tesla (1856-1943) came to the United States in 1884 from Yugosiavia. He arrived during the battle of the currents between Thomas Edison, who
More informationWYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE
WHITE PAPER WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE EXPLANATION AND ASSISTANCE FOR APPLYING SOLID STATE SOFT STARTERS IN TRADITIONAL REDUCED VOLTAGE APPLICATIONS Introduction..............................................................2
More informationTRAMS TROLLEY-BUSES SUBWAY
9 FT-100-600 Traction Inverter for Asynchronous Drives 11 FT-105-600 Traction Inverter for Asynchronous Drives 13 FT-170-600 Traction Inverter for Asynchronous Drives 15 FT-300-600 Traction Inverter for
More informationWWW.SMETS-TECHNOLOGY.COM COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH 01. 2013 INNOVATIONS FOR POWERFUL PERFORMANCES
WWW.SMETS-TECHNOLOGY.COM COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH 01. 2013 INNOVATIONS FOR POWERFUL PERFORMANCES COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK PAGE 02 ENGLISH STATUS 01. 2013
More informationNXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
More informationJEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual
JEFFERSON ELECTRIC, INC. Buck-Boost Transformer Application Manual Revised on February 15, 2012 Table of Contents I. Introduction... 2 II. Choosing the Proper Transformer... 2 III. Rapid Selector Charts...
More informationSpecifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
More informationPhase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION
Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions by Howard Abramowitz, Ph.D EE, President, AirCare Automation Inc. Abstract - Single Phase AC motors continue to be
More informationContactless Power Transfer : Inductive charging of EV
Contactless Power Transfer : Inductive charging of EV 7-12-2010 P.Bauer Delft University of Technology Challenge the future EV have to be charged December 7, 2010 2 2 Chicken and egg problem December 7,
More informationIntroduction to Aircraft Design and Aviation Systems (ENG3005)
Chapter 3 Emergency power generation 1. Power distribution 1.1 The power source for many civil aircraft: a.main aircraft generator : through a Generator Control Breaker (GCB). Controlled by Generator Control
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationC Standard AC Motors
C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
More informationServo drives. Compact converter IndraDrive Cs
Compact converter IndraDrive Cs 2 Bosch Rexroth AG Electric Drives and Controls Documentation Highly versatile, extremely compact drives Power range 100 W to 9 kw Multi-protocol-enabled, Ethernet-based
More informationTorque control MSF Softstarter
Torque control MSF Softstarter INTRODUCTION Soft starting an AC motor refers to any one of several starting methods that limit the starting current and torque of the motor. The method discussed in this
More informationANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
More informationKinetic energy recovery on railway systems with feedback to the grid
Kinetic energy recovery on railway systems with feedback to the grid Authors: J.M. ORTEGA, METRO DE BILBAO;S:A: H. IBAIONDO, A. ROMO. INGETEAM TRACTION,S.A. 1. Introduction The increasing concern with
More informationOne Seven... the future of firefighting
When you re walking into hell... everything at your fingertips should be this easy. One Seven... the future of firefighting Mobile technology EN Gimaex your competent partner Gimaex is the leading European
More informationOil / Air Cooling Units for mechanical engineering and mobile hydraulics
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 viflow@viflow.fi www.viflow.fi
More informationDocumentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
More informationThree-Phase Electric Power Distribution for Computer Data Centers
Three-hase Electric ower Distribution for Computer Data Centers WHITE AER E901 Geist January 008 Summary This paper will describe the characteristics of three-phase power and outline the advantages of
More informationSYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
More information/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE
Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic
More informationN-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt
N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING Flygt The Concept N-Pump series. Bringing NEW levels of efficiency to wastewater handling applications Reduced pumping efficiency,
More informationVariable Frequency Drive Troubleshooting with U1610A/U1620A
Variable Frequency Drive Troubleshooting with U1610A/U1620A Application Note Electric motors form the backbone of most industrial and manufacturing environments. Variable frequency drives (VFDs) (also
More informationADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES
ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES by Kazuhiro Takeda Research Manager, Research and Development Center and Kengo Hirano Instrument and Control Engineer,
More informationSpeed Control Motors. Speed Control Motors. Brushless Motor's Structure and Principle of Operation H-40. Structure of Brushless Motor
Speed Control Speed Control Brushless Motor's Structure and Principle of Operation Structure of Brushless Motor Ball Bearing Shaft Brushless motors have built-in magnetic component or optical encoder for
More informationMINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at www.ktr.com
MINEX - 171 Table of contents NEW MINEX - 171 Coupling description 173 Technical description 174 s A 22/4 to B 60/8 with containment shroud made of stainless steel 175 s A 75/10 to F 250/38 with containment
More informationABB drives. Technical guide No. 4 Guide to variable speed drives
ABB drives Technical guide No. 4 Guide to variable speed drives 2 Guide to variable speed drives Technical guide No. 4 Technical guide No. 4 Guide to variable speed drives Copyright 2011 ABB. All rights
More informationSPEED CONTROL SYSTEM
SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W
More informationDHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR
1 DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING Constructional details Types of rotors EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR PART A 1.
More informationSingle-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
More information(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.
ELECTRIC MOTORS Enclosures for Motors Types of motor enclosures generally used in farm applications: (1) Open type; drip proof or splash-proof. A general purpose motor for use in dry locations which are
More informationListed are common requirements that apply to existing solar installations when altered, added to or reconfigured.
SOLAR ALTERATIONS REQUIREMENTS August 2015 These requirements address typical alterations to solar installations; they cannot address every scenario. In Victoria, an alteration to a solar installation
More informationTransformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)
Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS) 2 European MEPS for transformers The EU MEPS (European Minimum Energy Performance Standard) Transformers
More informationTransformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
More informationAchieving the impossible
1 Achieving the impossible Taking control of shore power with the Phoenix Multi/MultiPlus from Victron Energy * Sometimes the features of a new product are so unique that the benefits are difficult to
More informationDC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility
DC Traction Power Supply Powerful, efficient and safe siemens.com/mobility 2 DC traction power supply More people, more challenges, one solution: Complete mobility. Needed more than ever before: Not only
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationUnderstanding the Alternator
http://www.autoshop101.com THIS AUTOMOTIVE SERIES ON ALTERNATORS HAS BEEN DEVELOPED BY KEVIN R. SULLIVAN PROFESSOR OF AUTOMOTIVE TECHNOLOGY AT SKYLINE COLLEGE SAN BRUNO, CALIFORNIA ALL RIGHTS RESERVED
More information912. The engine for construction equipment.
912. The engine for construction equipment....... 24-82 kw at 1500-2500 min -1 These are the characteristics of the 912: Air-cooled 3-, 4-, 5-, 6-cylinder naturally aspirated in-line-engines. Direct injection.
More informationmk Conveyor Technology
mk Conveyor Technology One construction kit many options Base Technology Profile Technology Conveyor Technology Factory Equipment Linear Motion Advantages of the mk modular system Everything comes from
More informationSRS2025. Home & small Business. Energy Storage Solution
SRS2025 Home & small Business Energy Storage Solution Leclanché Lithium-ion complete system The ideal energy storage system for Home & Small Business Lithium-ion battery storage systems Home & Small Business
More informationCompact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details!
Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details! Air. CompressedAir. BogeAir. Now you can! CM compact module 2.2 7.5 kw Effective free air delivery:
More informationMetering for today s systems
Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single
More informationP 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationInverter / Charger Installation General Operations and AC and DC Connections
Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better
More informationA Comparison of AC and DC Power Distribution in the Data Center Transcript
A Comparison of AC and DC Power Distribution in the Data Center Transcript Slide 1 Welcome to the Data Center University course on the A Comparison of AC and DC Power Distribution in the Data Center. Slide
More informationSiemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
More informationDiode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.
Diode Applications Diode Switching As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off. Voltage Rectifier A voltage rectifier is a circuit that converts an
More informationElectrical System From The Top Down By Rick Denney, GMC Eastern States April 2006
GMC Motorhome Electrical System From The Top Down By Rick Denney, GMC Eastern States April 2006 The electrical system of the GMC is fairly simple when considered as a system, but it s easy to get lost
More informationTHE INPUT/OUTPUT SYSTEM. Key Points
M O D U L E T W O THE 2 INPUT/OUTPUT SYSTEM Key Points In the first module, you learned about the basic architecture and operation of the Allen-Bradley Micrologix 1000, including a brief introduction to
More informationleader in voltage regulators since 1946
Contents: Page REGULATORS - Introduction: Features - Applications... 3 - Construction - General specifications... 4 - s Available: Terminology... 5 - Single-phase variable autotransformers... 6-7 - Three-phase
More informationUnit 33 Three-Phase Motors
Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation
More informationTOWER BETON - VERTICAL BATCHING AND MIXING PLANTS CONCRETE BATCHING PLANTS
TOWER BETON - VERTICAL BATCHING AND MIXING PLANTS CONCRETE BATCHING PLANTS TOWER BETON Meeting the demands of customers needs and applying the most modern technology is what SIMEM focused on while designing
More information7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units
Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast changing world. We help our customers worldwide
More informationDiesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
More informationMC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.
Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable
More informationSMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
More informationBaldor Electric Position on DOE Small Motor Rule
Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department
More informationHyPM Fuel Cell Power Modules
HyPM Fuel Cell Power Modules HyPM XR Fuel Cell Power Module for stationary and backup power applications HyPM HD Fuel Cell Power Module for mobility applications Purpose-built to deliver the best in performance
More informationCompetency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6
Table of Contents (MEC 6)... 1 Function: Operate Vessel Machinery and Systems... 1 Diesel engines.... 1 Operational procedures.... 3 Operate and monitor a vessel s engines and auxiliary equipment.... 4
More informationInverters. The product range.
s. The product range. Brings more sun to the grid. Energy efficiency as a philosophy. What drives the company. Diehl Controls, a division of the Diehl Group, is home to the Diehl AKO, PLATINUM and Diehl
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationGENERAL POWER SYSTEM WIRING PRACTICES APPLIED TO TECNADYNE DC BRUSHLESS MOTORS
1/5/2006 Page 1 of 6 GENERAL POWER SYSTEM WIRING PRACTICES APPLIED TO TECNADYNE DC BRUSHLESS MOTORS 1. Introduction The purpose of this application note is to describe some common connection and filtering
More informationProducts and solutions for machine builders (OEM) 100% electricity
Products and solutions for machine builders (OEM) 100% electricity www.lovatoelectric.com Tra dition and innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters
More informationApplication for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection
Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection (See ARSD chapter 20:10:36 for the requirements for a Tier 2, Tier 3, or Tier 4 Interconnection.) Applicant/Interconnection
More informationProduct Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
More informationTrade in Environmental Goods & Services Solar Energy in Kenya
Trade in Environmental Goods & Services Solar Energy in Kenya Dr. Moses Ikiara Kenya Institute for Public Policy Research and Analysis WTO Workshop, Geneva, Switzerland September 23 25, 2009 Outline Introduction
More informationMICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS
MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS C.P. ION 1 C. MARINESCU 1 Abstract: This paper presents a new method to supply single-phase loads using a three-phase induction
More informationProducts and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
More informationThe Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction
The Facts About Harmonics and Power Factor Power Quality: Harmonics & Power Factor Correction 1 Agenda I. Harmonic Basics II. Harmonic Mitigation Methods III. Active Harmonic Filters IV. Applications V.
More information