FS720 Fire detection system
|
|
- Hilary Ray
- 7 years ago
- Views:
Transcription
1 FS720 Fire detection system Market package 3.0 Cerberus PRO Control panel family with 3 station types Microprocessor-controlled fire detection system Compact fire control panels for 252 to 504 addresses PC-based operation (Cerberus-Remote) via Fast-Ethernet Free control logic Phased evacuation Network cluster (C-WEB/SAFEDLINK) Redundant network nodes Failsafe loop topology Up to 6000 addresses and 32 stations (control panels, operating panels) Fast data transfer up to 32 kbps (can be adjusted to line quality) Hierarchical networks via Ethernet backbone (C-WEB/LAN) Multi-cluster network interconnected via Industrial Ethernet (fiber-optic) EN 54-compliant network System-wide redundancy Up to 4 clusters (with up to 6 stations per cluster) Up to 64 stations in entire network
2 High-performance peripherals From bus-powered sounders, floor repeater displays and floor repeater terminals All Cerberus PRO FD720 devices are supported Time-saving functions for installation, startup and service Ergonomic Cerberus-Engineering-Tool with familiar Windows mechanisms Auto configuration (self-addressing) Zones and customer texts can be assigned without reading in the hardware Remote transfer of diagnostic data (e.g. firmware versions) General functional principle The FD720 devices register signals, compare and evaluate them on the basis of stored patterns. If a fire is detected, the data is transferred to the fire control panel, and released fire controls. The processor in this device triggers centralized and decentralized control functions via input and output modules. It does not matter whether the network has a ring structure and is therefore failsafe, is Ethernet or a combination of the two. In case of malfunctions, the degrade function guarantees operation of the system components that are impaired by the malfunction. All signals are automatically displayed on the operating panel based on their origin, or can be handle using operating functions. In any event, the messages together with a timestamp are entered in the event memory so that the locations where fire started can be ascertained subsequently. System overview FS720 The FS720 fire detection system is the new global generation of Cerberus PRO fire control panels. It combines the highest safety standards with international product innovations and cutting-edge technology. The fire control panels, fire terminals and the shared C-WEB network are designed in accordance with EN 54-2, EN 54-4 and other national supplementary requirements. They represent the heart of the FS720 fire detection system. The highest levels of detection reliability and optimum adaptability to customers' existing systems are achieved in conjunction with intelligent FD720 peripheral devices (C-NET). FC722 fire control panels The size of this fire control panel makes it ideal for smaller applications (e.g. workshops and hotels). It is possible to connect a total of 2 (4) loops or 4 (8) stub lines with up to 252 addresses. Its strength lies above all in its compactness that permits quick and efficient installation. FC724 fire control panels The FC724 fire control panel can have 4 (8) loops or 8 (6) stub lines with up to 504 addresses. This means they offer sufficient capacity for medium-sized fire detection installations (e.g. regional banks and office complexes). 2
3 FC726 fire control panel The FC726 is a modular fire control panel with integrated user interface and processes signals from Cerberus PRO FD720. A built in card cage with 5 plug-in position enables the application of: C-NET line cards FCL200-A (for additional lines) I/O-card FCI2008-A (with 2 programmable in-/outputs) The FC726 supports up to 52 addresses FT724 fire terminal All fire control panels have an integrated user interface. However, the FT724 fire terminal is available for remote operating panels. The view shown on this compact person machine interface can be freely allocated between fire control panels. Max. 5 fire terminals with system wide view programmable. Floor repeater terminals and floor repeater display Messages from relatively small monitoring areas (e.g. hospital wards) can be detected by FT20 floor repeater displays and operator intervention is even possible as well using FT200 floor repeater terminals. These devices are C-NET participant. National supplements Fire brigade person machine interfaces Evacuation person machine interfaces Germany France Netherlands 3
4 FS720 Networks Interfaces C-NET Cluster (C-WEB/SAFEDLINK) Backbone (C-WEB/Ethernet) Ethernet Network for connecting Cerberus PRO FD720 devices Network for creating a cluster of up to 32 stations (without connection to a Danger Management System) Network for connecting multiple clusters via a fiber-optic Industrial Ethernet (max. 64 stations) Connection to Siemens Danger Management System Cluster (C-WEB/SAFEDLINK) Up to 32 fire control panels und fire control terminals can be connected in a single cluster (C-WEB/SAFEDLINK) or up to 6 stations when the cluster is connected to a danger management system. The innovative redundant network nodes not only set new standards in terms of failsafe characteristics but also for high-speed data transfer. It is also possible to extend the distance between panels by the use of a repeater. Backbone (C-WEB/LAN ) Using a fiber-optic Backbone (C-WEB/LAN) up to 4 of the above mentioned clusters (with up to 6 stations each) can be networked. This topology enables the construction of an EN 54-compliant network with up to 64 panels and fire terminals. Management station A danger management station can be connected directly to any network type: standalone panel, cluster (C-WEB/SAFEDLINK) or hierarchical network (C-WEB/LAN). When such connections should be made via a customer network, then a Security module shall be used to provide Firewall protection (and a VPN connection if the management station is not within the customer network itself). 4
5 C-NET overview Characteristics Optimum use of customers' resources Integration of intranet. Operation of individual control panels or a network from the customer's PC using the Cerberus-Remote Software. Replacement of redundant cabling by redundant network nodes Operation of floor repeater displays and terminals on the field data bus (C-NET) High availability Remote control via Internet Efficient troubleshooting via remote diagnostic data transfer Highest levels of reliability and secure detection Primary site protection through auto configuration Simple handling Straightforward and time-saving operation by user-friendly, self-explanatory menu structure. Prefabricated control panels for efficient installation Remote access to all stations in the system via one network station Topology upload (periphery and installation) into the tool Little training required because of a consistent operating and hardware concept with one engineering tool (Cerberus-Engineering-Tool) for the entire system 5
6 High speed Rapid data transfer at 32 kbps in the failsafe network and 00 Mbit/s in the Ethernet network Short download and upload times Preparation of logical configuration data before installation of the system Station types in the C-WEB Housing with integrated FC722 FC722 FC724 FC726 FT724 operating unit Housing type Dimensions (W x H x D) mm Number of loops (with loop extension) or number of stub lines Plug in positions (C-NET and I/O cards) Standard 430 x 398 x 60 2 (4) 4 (8) Comfort 430 x 796 x 60 Comfort 430 x 796 x 60 Modular 430 x 796 x 260 Eco 430 x 398 x 80 4 (8) 4 (8) 8 (6) 8 (6) 5 Max. number of addresses Outputs for alarm Monitored control output Potential-free changeover contact Outputs for fault Monitored control output Potential-free changeover contact Outputs for conventional horn lines, monitored (with sounder module) (4) 2 (8) Free programmable inputs/outputs 24 V Free programmable inputs/outputs with a max. of 5 additional I/O cards 60 Battery capacity (internal) 2 x 2 V, 2 Ah 2 x 2 V, 26 Ah 2 x 2 V, 26 Ah 2 x 2 V, 45 Ah 2 x 2 V, 7 Ah (optional) Ethernet connection Degrade mode and degrade supply Emergency power supply Standby operating time up to 72 h (depending on configuration) Organizational logic The Alarm Verification Concept (AVC) permits the control panel organization to be freely adapted to the customer's requirements. Time functions During system tests or when detector groups are switched off, timeout functions make sure that these detector groups are reactivated. Event memory Up to 2000 events can be called up for each station according to various criteria. Ground fault monitoring All outgoing detector lines from the control panel are monitored for ground faults. 6
7 Hardware expansion Stations FC722 FC724 FC726 FT724 Network module (SAFEDLINK) Redundancy module for networking Repeater (SAFEDLINK) Loop extension (C-NET) Line cards (C-NET) I/O cards (programmable) Sounder module RS232 module (isolated) RS485 module (isolated) Fire brigade periphery module (DE) Event printer Operating add-on Refer to the following product data sheets for details about C-WEB stations: FC722-xx A6V FC724-xx A6V FC726-xx A6V FT724-xx A6V Refer to the following data sheets for details about C-NET floor repeater terminals, floor repeater displays, mimic display driver, conventional fire control unit FC0 and extinguishing control unit XC0: FT200-A, FT20-A FT200-A A6V FC0 A6V027745, A6V XC Refer to the corresponding product data sheets for details about the other peripheral devices. 7
8 Peripheral devices in the C-NET OP, OH, HI, FDF, FDL, FDM Latest generation devices with evaluation algorithms. Signal processing with detection algorithms and ASAtechnology. Automatic address allocation during commissioning. DBS, FDS Instead of complicated additional cabling, FD720 technology permits the operation of sounder bases, alarm sounders and/or alarm sounder beacons on the detector bus, i.e. supply and communication are via the C-NET. LaserFocus VLF-250/-500 FDCW, SMF The aspiration smoke detector is a very early warning smoke detector (Aspirating Smoke Detector ASD) designed to protect small, business-critical environments. The detector works by continually drawing air into sample holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke. Wireless fire detection system can be fully integrated into the C-NET. Wireless transmission replaces complex or visible cable installation and is therefore particularly interesting for museums, churches etc. The system also offers the additional advantage that installation is possible without system interruption. The wireless gateway FDCW22 communicates with up to 30 wireless detectors (smoke detectors and manual call points). 8
9 FDCI, FDCIO FDCL22, FDCL22-M FT20-A, FT200-A Statuses can be monitored using the input module. (e.g. door monitoring, ventilation checks or for sprinkler alarm triggering.) The input/output modules are used for decentralized activation of fire doors, ventilation systems, etc., the input can be used for acknowledgement or also for status monitoring purposes, or else for activating the standard interfaces extinguishing (SST) according to VdS. The transponder has 2 inputs/outputs and can parameterized for connection of collective fire detectors Siemens or Synova 300/600 (GMT/conventional line, GMT/conventional line with shunt-zener-diode barrier (SB3) for explosion-hazard areas) for monitored controls of alarm devices Line separators can be connected in between to ensure that several stub lines will not fail if there is a short circuit. The line separator is used where several stubs are connected to the C-NET at one point if there is no other FD720 device between the branches. Smaller areas of the fire detection system can be operated or displayed using the FT200 floor repeater terminals and FT20 floor repeater displays operated in the C-NET. The personnel responsible at the customer's premises (e.g. ward sisters) have access to a clearly structured user interface for customer-specific plain texts to enable events to be localized unambiguously. The display type corresponds to the FT724 fire terminal. FT200-A FC0, XC0 The mimic display driver operated in the C-NET has 2x24 outputs for LED activation for mimic display panels. 2 control outputs for 'Local buzzer' and 'LED operation' 2 inputs for 'Switch-off buzzer' and 'Lamp test' Connection to LED via flat cable F50F40 (50-wire, 24 red LEDs, cable length m The conventional fire control panel FC0 and the extinguishing control panel XC0 can integrated as autonomous control panels into the C-NET (via in-/output module FDCIO). Relevant events are transferred to the connected fire control panel. Each line can be individually configured to AlgoRex collective or Synova conventional. This allows to connection to AlgoRex DScollective, Synova conventional detectors as well as special detectors like DF9, FDF2x-9 flame, DLO9, FDL24-9 linear detectors. 9
10 Siemens Switzerland Ltd Industry Sector Division International Headquarters Gubelstrasse 22 CH-630 Zug Tel Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document Nr. A6V _b_en_-- Manual FS720 Edition Register
FC722 Fire control panel
FC722 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationFire control panel (modular)
FC726 Cerberus PRO Fire control panel (modular) FS720 series, IP6 Modular, pre-assembled, microprocessor-controlled fire control panel with user-friendly integrated operating unit for up to 1512 addresses
More informationFC722. Fire control panel. Cerberus PRO. FS720 series, IP6
FC722 Cerberus PRO Fire control panel FS720 series, IP6 Compact, pre-assembled, microprocessor-controlled fire control panel with integrated operating unit for up to 252 addresses Fire control panel can
More informationAnswers for infrastructure. Sinteso control panels clear concept, efficient operation
Answers for infrastructure. Sinteso control panels clear concept, efficient operation Sinteso: innovation based on experience from Siemens Sinteso is a comprehensive system for fast, reliable fire detection,
More informationCerberus PRO product catalog
Cerberus PRO product catalog Fire safety products and accessories Answers for infrastructure. Everything you need for fire safety and security From fire protection and fire detection to safety and security
More informationDBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders
DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders For the automatic addressable detector bus C-NET Cerberus PRO Sounder base DBS720 11 selectable tones, 2 programmable activation levels Sound intensity
More informationFDCI222, FDCIO222, FDCIO224 Input module Input/output modules
FDCI222, FDCIO222, FDCIO224 Input module Input/output modules addressable (FDnet/C-NET) Sinteso Cerberus PRO Input module FDCI222 with 4 monitored contact inputs for the acknowledgement of technical states
More informationProduct Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
More informationInput module, input/output module
Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input
More informationVoice alarm system E100 the new standard for safe evacuation
Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when
More informationBegin using tomorrow s security features today.
Begin using tomorrow s security features today. Advantage Services : Life Cycle for Security Systems Building Technologies Software Update/Upgrade Technology Strategy Documentation System Modernization
More informationHow can I protect valuable assets from fire and ensure business continuity?
How can I protect valuable assets from fire and ensure business continuity? XC10 compact panels combine fire detection and extinguishing control for comprehensive safety. Answers for infrastructure. Compact
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationFire alarm system EBL512 G3
Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands
More informationDLO1191 Linear smoke detector
DLO1191 Linear smoke detector collective/synoline600, interactive AlgoRex Synova Reliable smoke detection in large-volume rooms (inside application) Detection distance from 5 100 Meter Efficient signal
More informationMM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.
MM8000 safety and security with smart danger management A scalable and flexible management station for any requirement Answers for infrastructure. Sophisticated technology for comprehensive safety Safety
More informationElectronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
More informationAlarmSense 2-wire detection and alarm system. Product Guide
AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority
More informationMaximum uptime and optimum fire safety for your data center
Maximum uptime and optimum fire safety for your data center Integrated and tailored fire safety solutions from one partner Answers for infrastructure. Complete solutions for a safe data center with a single
More informationSiemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/
More informationLMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.
LMS The modular management system for condensing boilers Control Products & Systems OEM Answers for infrastructure. LMS advanced electronics and proven software At times of dwindling resources, rising
More informationMaximum uptime and optimum fire safety for your data center
Maximum uptime and optimum fire safety for your data center Integrated and tailored fire safety solutions from one partner Answers for infrastructure. Complete solutions for a safe data center with a single
More informationFire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
More informationBuilding Technologies. Access Control. SiPass integrated Fully expandable system that grows with your business
s Building Technologies Access Control SiPass integrated Fully expandable system that grows with your business SiPass integrated : a system, that leaves nothing to be desired. SiPass integrated is the
More information25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
More informationEDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk
More informationNJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
More informationFC18 Controller(Interlocking) Product Manual
Controller(Interlocking) Product Manual 20 controller with 1 line card, max. 252 points 40 controller with 2 line card, max. 504 points Characteristic Multi-language operation menu designed with Windows-like
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationData Centre alwas protected always up and running.
Data Centre alwas protected always up and running. Stefano Valdrighi - Siemens Business continuity is the critical asset to protect 609,500 Average cost per downtime 7,908 Average cost per minute The total
More informationHighly flexible the right KNX/DALI gateway for every requirement
The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationRepeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
More information25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals
INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce
More informationSiemens and National Instruments Deliver Integrated Automation and Measurement Solutions
Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions The Need for Integrated Automation and Measurement Manufacturing lines consist of numerous decoupled systems for
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationConventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
More informationGST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
More informationProfessional fire alarm panel for small and medium-sized objects. Compact
Compact Professional fire alarm panel for small and medium-sized objects ESSER by Honeywell: The experts for safety in buildings With a comprehensive and future-oriented portfolio in the fields of fire
More informationPLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
More informationBuilding Technologies
Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual
More informationModule 5. Fire and Emergency Alarm System Part I- Basics
Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationGSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
More informationINTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
More informationQFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationFIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19
TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as
More informationradio fire alarm system Installed with minimum disruption Provides maximum protection
radio fire alarm system Installed with minimum disruption Provides maximum protection Key features Fully Addressable Intuitive Menu Structure 4 Access Levels Pre-Alarm Warning Head Contaminated warning
More informationThe ABB i-bus KNX Room Master Concept Your first step into the KNX world
The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,
More informationIntrusion. IC60 security meets design. Answers for infrastructure.
Intrusion IC60 security meets design Answers for infrastructure. 1 Welcome home There is no better feeling than knowing your loved ones and your home are safe. Now imagine if you could improve both your
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationFIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this
More informationFIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
More informationMore efficiency in office buildings with HVAC, lighting and security
The worldwide standard for home and building control More efficiency in office buildings with HVAC, lighting and security Simply more productive: Higher energy efficiency and more flexibility thanks to
More informationUNIVERSAL TRAFFIC CONTROLLER
Eventueel subtitel Eurocontroller EC-2 UNIVERSAL TRAFFIC CONTROLLER EuroController EC-2 The Peek EuroController EC-2 is a state-of-the-art traffic controller, rooted in a long tradition of innovation and
More informationS7 for Windows S7-300/400
S7 for Windows S7-300/400 A Programming System for the Siemens S7 300 / 400 PLC s IBHsoftec has an efficient and straight-forward programming system for the Simatic S7-300 and ern controller concept can
More informationFN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationFIRE ALARM SYSTEM. reliable fire detection and alarm signalling system
FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience
More informationINTELLIGENT MONITORING FOR SAFER BUSINESS
INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS TECHNOLOGY FOR A BETTER WORKING WORLD CHOOSE PANASONIC FIRE SOLUTIONS AND YOU RE CHOOSING WORLD-CLASS PROTECTION With more than
More informationSoftware INTERACT. MachineLogic. The Shortest Distance Between Man and Machine
Software INTERACT MachineLogic The Shortest Distance Between Man and Machine Fully IntegrateYour HMI and PC-Based Control With MachineShop Project Management MachineShop s Project Management is a simple,
More informationMore efficiency in schools with HVAC, lighting and security
The worldwide standard for home and building management More efficiency in schools with HVAC, lighting and security Simply first class: Higher energy efficiency and more flexibility thanks to Synco HVAC
More informationINTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
More informationBS5839 Part 1:2002 Overview
BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire
More informationDM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button
DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control
More informationUsing your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
More informationFAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL
FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL NOT YOUR STANDARD FIRE ALARM PANEL FLEXIBILITY, SPEED, INTELLIGENCE CyberCat the digital, peer-to-peer bi-directional, communication system that
More informationDocumentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
More informationFX 3NET + SLC FIRE ALARM SYSTEM Part 1: General Rules
Planning Instruction 66571758GB0 49/2011 Fire Detection FX 3NET + SLC FIRE ALARM SYSTEM Part 1: General Rules These are the planning instructions for an FX 3NET fire detection and alarm system consisting
More informationWhite Paper: Nurse Call Systems and IT Networks
Intelligent Life Care White Paper: Nurse Call Systems and IT Networks Creating Synergies through Integrated System Landscapes The saving potential of a common infrastructure is quite obvious: Standard
More information3468-00 Lighting and Fire Alarm Training System Add-On
3468-00 Lighting and Fire Alarm Training System Add-On LabVolt Series Datasheet Festo Didactic en 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Additional Equipment
More informationHONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
More informationDiscovery 1-4 Loop Analogue Addressable Control Panel Application Guide
Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware Specifications 7 4.0 Software
More informationwireless alarm system reliable protection for small-size buildings
wireless alarm system reliable protection for small-size buildings The MICRA system is an ideal solution wherever you need a simple and reliable alarm system with GSM communicator. The MICRA system has
More informationMonitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution
Monitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution ImpactSentinel Natural Hazard Sensors und Systems hazard signalization in protection fences overstress, shock
More informationExpansion Modules & Accessories
HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and
More informationFIRE ALARM AND VOICE COMMUNICATION SYSTEM Request for Qualifications
FIRE ALARM AND VOICE COMMUNICATION SYSTEM Request for Qualifications Proposal Request Joliet Junior College, Illinois Community College District 525 (JJC) is soliciting proposals from vendors for a fire
More informationFIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
More informationSubstation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
More informationT a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
More informationFire detection in kitchens
Fire detection in kitchens Protection of people, business continuity and reputation Large cooking vessels, frying pans, and deep frying vats present a very serious fire hazard in commercial kitchens. This
More informationControl and Indicating Equipment
VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Control and Indicating Equipment Requirements and Test Methods VdS 2540en : 2010-12 (02) Publishing house: VdS Schadenverhütung GmbH
More informationWeb Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
More informationFire Alarm Engineering Best Practices. CFAA NCA Technical Seminar 2014
Fire Alarm Engineering Best Practices CFAA NCA Technical Seminar 2014 2 Overview Code Compliance Equipment Selection and Layout Drawings, Specifications Commissioning and Acceptance Miscellaneous Goals
More informationFIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
More informationMicroLink dlan ADSL Modem Router
ADSL HomePlug Router High-speed router with integrated HomePlug adapter and ADSL modem for data transfer via the household electricity circuit PCs in different rooms or on different floors are easily interconnected
More informationProduct Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels
User Manual Product Data Sheet User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions
More informationINTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
More informationGen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications
Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection
More informationDTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
More informationMM8000 highest safety and security with intelligent danger management
MM8000 highest safety and security with intelligent danger management A scalable and flexible management station for any requirement Answers for infrastructure. Sophisticated technology for comprehensive
More informationPanel Controller MPC-xxxx-B FPA-1200-MPC. Operation guide
Panel Controller MPC-xxxx-B FPA-1200-MPC en Operation guide Panel Controller Table of Contents en 3 Table of Contents 1 For your information 8 1.1 Depiction of steps 8 1.2 Calling up the start menu 8
More informationWhite paper The future role of ethernet and the trend to decentralised control solutions
White paper The future role of ethernet and the trend to decentralised control solutions The driving force behind progress in Industrial automation in the last 10 years has without doubt been the networking
More informationBIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
More informationInstallation Handbook. Interactive Fire Alarm System Release 3. Repeater Panel BU-320 / Information Panel BV-320
Interactive Fire Alarm System Release 3 Installation Handbook Repeater Panel BU-320 / Information Panel BV-320 Protecting life, environment and property... P-ASAFE/RI/DE Rev. A, 010531 COPYRIGHT This publication,
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationControl/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
More informationC E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems
P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier
More informationD200+ Auto-Dialler Installation/Operators Manual
D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station
More informationSFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
More information