Fire control panel (modular)
|
|
- Carmel Dennis
- 7 years ago
- Views:
Transcription
1 FC726 Cerberus PRO Fire control panel (modular) FS720 series, IP6 Modular, pre-assembled, microprocessor-controlled fire control panel with user-friendly integrated operating unit for up to 1512 addresses Processes signals from various detector series: FD720 devices from the Cerberus Pro series SynoLOOP devices Fire control panel can be used as a standalone version or can be networked Up to 64 stations, such as control panels and terminals, can be linked to form a network Integrated degraded mode function Redundant network node, degraded mode operation according to EN 54 Fast Ethernet interface for a heterogeneous network Can be extended by adding printer, key switches, LED indicators Card cage for up to five module bus cards (line and I/O cards) Hot plug system: Module bus cards can be changed during operation. Slots for RS232, RS485 serial ports Emergency power supply for emergency operating time of up to 72 hours Detection and automatic reading in (auto-configuration) of all Cerberus PRO devices, ready for operation immediately Floor repeater devices, alarm devices, and mimic displays on C-NET detector line Flexible configuration of complex applications and controls Control Products and Systems
2 System overview FC723 FT724 Repeater FN2002 Cluster (C-WEB/SAFEDLINK) FC726 Fire control panel SynoLOOP Explosionhazard area FDM233-Ex OOH740-A9-Ex Detection line collective Siemens, TM Synova SynoLINE300 or SynoLINE600 Remote access Engineering Tool, Operating Tool Transmission of an alarm signal Transmission of a fault signal via FCI2007-A1 FT2010/FT2011 Floor repeater terminal / Floor repeater display 24VDC ext. possible FDCI222 DBS720 HI722 FDCI723 4 inputs FDM22x FDCL221-Ex 2 inputs/outputs optionally DBS721 / DBS729 OH720 C-NET 4 (8) loops max. 504 adresses 1 output FDCIO221 24VDC ext. FDCIO223 1 input FDM221 Mimic display FT2001-A1 HI720 OH720 FDCI221 1 input FDCL221 OP720 OP720 stub line FDCW241 4 outputs 4 inputs FDCIO222 FDOOT271 Fire controls via FCI2008-A1 Conventional horn lines via FCI2009-A1 FDA221/ FDA241 FC10 or XC10 Fire detection or Extinguishing control unit collective FDM273 Radio detectors Possible extensions for card cage with five slots FCL2001-A1 Line card (FDnet/C-NET) 4x loops each with a maximum of 252 addresses, max. of 252 addresses per line card FCL7201-Z3 Line card (SynoLOOP) 4x loops each with a maximum of 128 addresses, max. of 512 addresses per line card FCI2007-A1 I/O card (RT) Outputs for alarm, fault, local alarm FCI2008-A1 I/O card (programmable) 12x freely programmable inputs/outputs per I/O card FCI2009-A1 I/O card (horn/monitored) 8x monitored horn outputs or monitored outputs Mixed usage possible, but with a max. of 1512 addresses per control panel 2
3 Networking of several fire control panels Up to 32 control panels and terminals can be linked to form a cluster (C- WEB/SAFEDLINK network). If the cluster is connected to a danger management system via BACnet, up to 16 control panels and terminals can be networked. Siemens Danger Management System Ethernet DL3750+ FT724/FC72x Matrix printer RS232 FC722 Repeater FN2002 Cluster (C-WEB/SAFEDLINK) In-/ Outputs 16 stations FC726 3
4 An optical Ethernet network (C-WEB/LAN) allows up to 14 clusters with up to 16 stations to be operated on one network. A maximum of 64 stations is supported in total. You will find details of system networking in product data sheet A6V
5 Function features The FC726 is a modular fire control panel with integrated operating unit that is intended for large sites and for modernizing existing large fire detection installations based on earlier systems. The FC726 processes signals from Cerberus PRO FD720 devices and from addressable devices based on earlier systems. The control panel may be used as a standalone unit or networked. The control panel and the fire detection system are custom-configured using the Cerberus-Engineering-Tool software. There is a card cage with five slots for inserting the following module bus cards: Line card (FDnet/C-NET) FCL2001-A1 (for extra lines) Line card (SynoLOOP) FCL7201-Z3 I/O card (configurable) FCI2008-A1 I/O card (horn/monitored) FCI2009A1 I/O card (RT) FCI2007-A1 Mixed use of all module bus cards line and I/O cards is possible In the event of a defect, the module bus cards can be replaced without the control panel having to be powered down. Customer texts can be adapted directly on the operating unit of the control panel or with the Cerberus-Engineering-Tool software. Up to 2000 events can be retrieved from the event memory based on various criteria. Automatic summer/winter time changeover Siemens danger management system can be connected 5
6 Function elements Operating unit The following elements are available on the operating unit: CPU module and electronics Ethernet connection Slots for RS232 and RS485 modules and network modules (SAFEDLINK) Space for 'Kaba' or 'Nordic' key switch Space for event printer Peripheral data bus connection for optional LED modules Periphery board The following elements are available on the periphery board: Connection terminals for C-NET lines (four loops with max. 504 devices), remote transmission (alarm, fault), horn outputs, configurable control inputs and outputs, monitored alarm and fault output, emergency supply, power supply Two slots for loop extension (C-NET) Card cage (5 slots) There is a card cage on the rear housing panel for using up to five module bus cards. Power supply unit 150 W, emergency power supply The power supply feeds the hardware and charges the batteries. In the event of a power cut, the batteries provide emergency current. Housing A pivoting mounting plate can be fitted for the following elements above the periphery board on the rear housing panel: 1x fire brigade periphery module 2x sounder modules (as an alternative to mounting on U-rail TS35) Configuration The FXS7212 Cerberus-Engineering-Tool allows the system to be customized. Application ranges The FC726 is ideal for medium-sized applications, e.g., for use in hotels, high schools, or office complexes. Within the context of modernization, it allows a gradual and seamless transition from older systems to Cerberus PRO. However, thanks to the flexible networking options, the FC726 can also be used for large-scale sites. Operation Each control unit has an integrated operating unit. The control panel can also be operated via a separate FT724 fire terminal. You will find details and more information in product data sheet A6V
7 Overview of FC726 fire control panel (modular) Control panel Housing extensions FC726-ZA FH7204-Z3 FH7205-Z3 Housing (Large) Housing (Large Extension) Housing (Large) 430 x 398 x 283 mm 430 x 796 x 283 mm Space for larger batteries 2x FA2007-A1 (45 Ah) or 2x FA2008-A1 (65 Ah) 4 loops with card cage for five module bus cards with power supply (150 W) Max. battery capacity 45 Ah For operating add-ons or Event printer Space for larger batteries 4x FA2006-A1 (26 Ah) or 4x FA2007-A1 (45 Ah) or 2x FA2008-A1 (65 Ah) Printer External printer Operating accessories FTO2001-A1 DL3750+ FCM7213-Y3 FCM7214-Y3 Event printer Matrix printer (external) 48 indicator groups with 96 indicator groups with RS232 interface one red/green + one yellow LED each one red/green + one yellow LED each RS232 module must RS232 module must for retrofitting for retrofitting be ordered separately be ordered separately Note installation depth (battery) Note installation depth (battery) 7
8 Layout of FC726 inside housing (Large) Basic equipment 1 Housing (Large) 2 Periphery board (4 loops) 3 Power supply (SV 24V-150 W) 4 Mains terminals on TS35 DIN rail 5 Operating unit 6 Card cage (5 slots) 7 Space for batteries Designation FH7205-Z3 FCI2004-A1 V24230-Z6-A5 FCM72xx-xx FCA2008-A1 17 Notes Items 1-6: Basic equipment Space for socket, relay modules Operating unit with CPU For five module bus cards 2x 12 V/17 45 Ah 8 A6V _h_en_-
9 Extensions 8 Relay module Z3B171 Relay for fire controls 9 Event printer FTO2001-A1 For logging events 10 Key switch (Kaba) FTO2005-C1 Key switch (nordic) FTO2006-B1 For operating access authorization 11 Mounting plate FHA2007-A1 E.g., for fire brigade periphery module 12 Loop extension (FDnet/C-NET) FCI2003-A1 For extending the number of loops from two to four, the number of addresses remains the same 13 Module bus cards: Line card (FDnet/C-NET) FCL2001-A1 For four extra C-NET lines Line card (SynoLOOP) FCL7201-Z3 For four extra SynoLOOP lines I/O card (programmable) FCI2008-A1 For twelve configurable inputs/outputs I/O card (horn/monitored) FCI2009-A1 For eight monitored horn outputs I/O card (RT) FCI2007-A1 For extra alarm and fault outputs 14 RS485 module (isolated) FCA2002-A1 For peripheral devices with RS485 interface 15 RS232 module (isolated) FCA2001-A1 for participant with RS232 interface 16 Network module (SAFEDLINK) FN2001-A1 For networking several stations 17 Repeater (SAFEDLINK) FN2002-A1 For extending the C-WEB system bus, max. 1x repeater (SAFEDLINK) between two stations (mounted directly on a plane surface, on a TS35 U-rail, or in housing FDCH221) 18 Sounder module FCA2005-A1 For splitting one conventional sounder into four 19 Battery (12 V, 26 Ah, VDS) FA2006-A1 For the emergency power supply Battery (12 V, 45 Ah, VDS) FA2007-A1 20 Fire brigade periphery module FCI2001-D1 For Germany (FBF, FSD, ÜE, FSE, ÖA, KL) 21 19" mounting kit FHA2016-A1 For installation in 19" third-party housing 22 License key Sx FCA20xx For special functions 23 Cable kit (communication) FCA2014-A1 For flexible connections running to the modules on the operating unit 24 Power supply kit (150 W, B) FP2005-A1 For extra power supply 25 Relay module Z3B171 Space for U-rail TS35 L=70 mm with max. four relay modules Technical data Mains voltage AC 115/230 V +10/-15 % Power supply 150 W Operating voltage DC V Operating current Max. 5 A Battery capacity 2x 12 V, 45 Ah Battery monitoring Yes Mains supervision Yes Connectable Cerberus PRO detector series FD720 (C-NET) Other addressable detectors which can be connected SynoLOOP Number of C-NET & SynoLOOP addresses Number of C-NET addresses Max. number of SynoLOOP addresses Max Max Max Number of integrated lines C-NET loops or stubs with loop extension Number of extra lines C-NET (4 loops or stubs per line card) SynoLOOP (4 loops or stubs per line card) Integrated inputs/outputs Relay output for RT alarm/rt fault Monitored outputs for alarm/fault/horn Freely configurable inputs/outputs Additional I/O cards I/O card (configurable) I/O card (horn/monitored) 4/8 8/16 Max. 20 loops/stubs Max. 20 loops/stubs 1/1 1/1/ x configurable inputs/outputs 2x supply outputs 24 V 8x monitored horn outputs 9
10 I/O card (RT) 1x alarm relay output and 1x fault relay output 1x voltage output 24 V 2x GPIO 1x monitored fault output 2x configurable outputs, monitored Operating unit Integrated Slots for RS232, RS485 serial ports 2 Slots for network modules 2 Slots for loop extension 2 Slots for module bus cards (on integrated card cage) Max. 5 Mounting spaces for cable kit (communication) 2 Sounder module Max. 2 Ethernet port RJ45 1 Operating temperature C Storage temperature C Air humidity (no condensation permitted) Dimensions (W x H x D) Without cover cap With cover cap Color Housing Cover cap Protection category (IEC 60529) Approvals VdS LPCB FM 95 % rel. 430 x 796 x 260 mm 430 x 796 x 283 mm ~RAL 7035, light gray ~RAL IP30 G bn/
11 Details for ordering Type Art. no. Designation Weight FC726-ZA S54400-C87-A1 Fire control panel (modular) kg Extensions Z3B171 BPZ: Relay module AC 250 V / 10 A (1 relay) kg FTO2001-A1 A5Q Event printer kg A5Q Spare printer reels (10 reels) kg FTO2005-C1 A5Q Key switch (Kaba) kg FTO2006-B1 A5Q Key switch (nordic) kg FHA2007-A1 A5Q Mounting plate kg FCI2003-A1 A5Q Loop extension (C-NET) kg FCL2001-A1 A5Q Line card (FDnet/C-NET) kg FCL7201-Z3 S54400-A116-A1 SynoLOOP line card kg FCI2007-A1 S54400-A20-A1 I/O card (RT) kg FCI2008-A1 S54400-A6-A1 I/O card (configurable) kg FCI2009-A1 S54400-A21-A1 I/O card (horn/monitored) kg FCA2002-A1 A5Q RS485 module (isolated) kg FCA2001-A1 A5Q RS232 module (isolated) kg FN2001-A1 A5Q Network module (SAFEDLINK) kg FN2002-A1 S24236-B2502-A1 Repeater (SAFEDLINK) kg FCA2005-A1 A5Q Sounder module kg FCA2014-A1 A5Q Cable kit (communication) kg FCI2001-D1 A5Q Fire brigade periphery module kg FH7204-Z3 S54400-B89-A1 Housing (Large Extension) kg FH7205-Z3 S54400-B86-A1 Housing (Large) kg FCM7213-Y3 S54400-B149-A1 Operating add-on (2xLED indicator) kg FCM7214-Y3 S54400-B150-A1 Operating add-on (4xLED indicator) kg FHA2016-A1 A5Q " mounting kit kg FN2006-A1 S54400-A109-A1 Fiber network module (SM) kg FN2007-A1 S54400-A110-A2 Fiber network module (MM) kg Auxiliary power FP2004-A1 A5Q Power supply kit (150 W, A) for installation kg supply into empty housing FP2005-A1 A5Q Power supply kit (150 W, B) for parallel connection kg Networks (backbone) FN2012-A1 S54400-B152-A Ethernet switch (modular) kg FCA2031 S54400-A153-A1 Connection module (MoNet) kg kg for cable VN2002-A1 S54400-A43-A1 Ethernet module (MM) kg VN2003-A1 S54400-A44-A1 Ethernet module (SM) kg FHA2029-A1 S54400-B79-A1 Installation kit (switch, comf.) kg Batteries FA2005-A1 A5Q Battery (12 V, 17 Ah, VDS) kg FA2006-A1 A5Q Battery (12 V, 26 Ah, VDS) kg FA2007-A1 A5Q Battery (12 V, 45 Ah, VDS) kg FA2008-A1 A5Q Battery (12 V, 65 Ah, VDS) kg License keys FCA2033-A1 S54400-P154-A1 License key (S1) kg FCA2034-A1 S54400-P155-A1 License key (S2) kg FCA2035-A1 S54400-P156-A1 License key (S3) kg External printer DL3750+ A5Q Matrix printer (external) kg Spare part A5Q Color ribbon for matrix printer DL kg 11
12 12 Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel Siemens Switzerland Ltd, 2009 Technical specifications and availability subject to change without notice. Document no. FS720 manual Edition
FC722. Fire control panel. Cerberus PRO. FS720 series, IP6
FC722 Cerberus PRO Fire control panel FS720 series, IP6 Compact, pre-assembled, microprocessor-controlled fire control panel with integrated operating unit for up to 252 addresses Fire control panel can
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationCerberus PRO product catalog
Cerberus PRO product catalog Fire safety products and accessories Answers for infrastructure. Everything you need for fire safety and security From fire protection and fire detection to safety and security
More informationInput module, input/output module
Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input
More informationDBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders
DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders For the automatic addressable detector bus C-NET Cerberus PRO Sounder base DBS720 11 selectable tones, 2 programmable activation levels Sound intensity
More informationFDCI222, FDCIO222, FDCIO224 Input module Input/output modules
FDCI222, FDCIO222, FDCIO224 Input module Input/output modules addressable (FDnet/C-NET) Sinteso Cerberus PRO Input module FDCI222 with 4 monitored contact inputs for the acknowledgement of technical states
More informationAnswers for infrastructure. Sinteso control panels clear concept, efficient operation
Answers for infrastructure. Sinteso control panels clear concept, efficient operation Sinteso: innovation based on experience from Siemens Sinteso is a comprehensive system for fast, reliable fire detection,
More informationDM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button
DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control
More informationDLO1191 Linear smoke detector
DLO1191 Linear smoke detector collective/synoline600, interactive AlgoRex Synova Reliable smoke detection in large-volume rooms (inside application) Detection distance from 5 100 Meter Efficient signal
More informationProduct Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
More informationElectronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
More informationFN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationPRODUCT CATALOGUE. www.detectomat.com
PRODUCT CATALOGUE 20 06 The Group contents 1. fire control panels 1.1 detect 3004 fire control panel and accessories...4-11 1.2 detect 3016 fire control panel and accessories...12-17 1.3 detect 3004/3016
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationBegin using tomorrow s security features today.
Begin using tomorrow s security features today. Advantage Services : Life Cycle for Security Systems Building Technologies Software Update/Upgrade Technology Strategy Documentation System Modernization
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationIMR 6000/10../20../30
IMR 6000/10../20../30 System frame Component of the MMS 6000 Machine Monitoring System Applications: Slots for adaptation of the signal processing periphery (monitors, logic cards and interface cards)
More informationSubstation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
More informationVoice alarm system E100 the new standard for safe evacuation
Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationNJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
More informationFC18 Controller(Interlocking) Product Manual
Controller(Interlocking) Product Manual 20 controller with 1 line card, max. 252 points 40 controller with 2 line card, max. 504 points Characteristic Multi-language operation menu designed with Windows-like
More informationRepeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
More informationChassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
More information(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationFire alarm system EBL512 G3
Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands
More informationDCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationHCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationBar Code Reader Series BCL 20 A flexible reader for a variety of applications
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.
More informationAlarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
More informationAutomation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
More informationHARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
More informationThe CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:
CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7
More informationINTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
More informationDelivers instant switching in four different modes for data center, control room, pooling and similar applications.
ServSwitch DKM & ServSwitch DKM FX Delivers instant switching in four different modes for data center, control room, pooling and similar applications.» Scalable DVI KVM Matrix Switch supports up to 288
More informationWeb Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
More informationGSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
More informationProduct Information Sheet UH28CS-12kV Hi Pot Tester
Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:
More informationQFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationCommunication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
More informationVEGA Analogue Addressable Control Panels
Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed
More information3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
More informationT1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More informationIPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationSIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
More informationABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
More informationExpansion Modules & Accessories
HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and
More informationconnecdim Gateway G1 Ethernet TCP/IP to DALI
Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration
More informationRemote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
More informationData Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
More informationHow can I protect valuable assets from fire and ensure business continuity?
How can I protect valuable assets from fire and ensure business continuity? XC10 compact panels combine fire detection and extinguishing control for comprehensive safety. Answers for infrastructure. Compact
More informationINTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
More informationAlliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
More information1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
More informationAXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationHighly flexible the right KNX/DALI gateway for every requirement
The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with
More information3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationDigital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
More informationOverview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara
More informationSet for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
More informationCOMPALARM AP GENERAL MAIN FEATURES
GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright
More informationMM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.
MM8000 safety and security with smart danger management A scalable and flexible management station for any requirement Answers for infrastructure. Sophisticated technology for comprehensive safety Safety
More informationData Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
More informationHoneywell Analytics Lines of Business
Honeywell Analytics Lines of Business Commercial Vulcain-brand gas detection from standalone units to fully engineered, multipoint systems, all offering cost-effective regulatory compliance» Applications:
More informationAIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
More information25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
More informationCP 342-5. Page 1342 Mar 2008 Siemens ITS
CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication
More informationBuilding Technologies
Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual
More informationGST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
More informationThe CP 342-5 provides access to different communication services of the PROFIBUS bus system:
SIPLUS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7
More informationHow To Buy An Fujitsu Primergy Bx400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server BLADE MADE EASY - tailor-made for medium-sized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well
More informationConventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
More informationCB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
More informationProgrammable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
More informationS-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationFiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
More informationKNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems
KNX Gateway Light-Control R User manual-ver.1 LC-IPGW-001 Intelligent Installation Systems Contents 1. Summary ---------------------------------------------------------------------------------------------------------------------
More information