MIXO modular units for multipole connectors

Size: px
Start display at page:

Download "MIXO modular units for multipole connectors"

Transcription

1 IXO modular units for multipole connectors Application IXO The IXO series is a system of modular units for special applications that uses the traditional ILE enclosures. Each enclosure can house different types of connections such as, for example: electric signals and contacts for the conduction of compressed air and liquids with pressure values of up to 8 bars. The inserts are arranged side by side to form a single compact block which is inserted into metallic frames with mandatory housings. Once the modules have been inserted and locked with the special tabs, the connector can then be inserted into the enclosure. The modular structure system makes it easy to access a series of contacts inserted in the frame (e.g., for substitution, checks or the addition of signals with new inserts for needs not foreseen during the initial installation) without having to disassemble the entire connector. The use of standard die-cast alluminium enclosures with degree of protection IP65 provides the possibility of innumerable applications. The IXO series may be used with 5 different frame sizes. The following table lists the frames and the metallic enclosures that may be used. frames one or two-lever metallic enclosures CX 0 T size 9.6 CX 0 T/T size.7 CX 0 T/T size 57.7 CX 0 T/T size 77.7 CX 06 T/T size 0.7 CX 0 T/T (x ) size 77.6 CX 06 T/T (x ) size 0.6 In addition, the IXO series can be used with the COB series panel supports frames CX 0 T/T CX 0 T/T CX 0 T/T CX 06 T/T panel supports part No. fixed: COB 06 BC and COB TCQ mobile: COB TS, COB TSS and COB 06 CS fixed: COB 0 BC and COB TCQ mobile: COB TS, COB TSS and COB 0 CS fixed: COB 6 BC and COB TCQ mobile: COB TS, COB TSS and COB 6 CS fixed: COB BC and COB TCQ mobile: COB TS, COB TSS and COB CS The IXO series currently includes 6 different types of inserts. The field of application is provided in the table at the bottom of the next page. 56

2 IXO modular units for multipole connectors Characteristics electric contacts in silver-plated or gold-plated brass with connections to the conductors via crimping, spring clamp or axial screw. pneumatic contacts in plastic with insertion tube connection modular inserts of identical size with insertion system for forming the complete module and frame lock tab. inserts in self-extinguishing thermoplastic material, reinforced with glass fibre, UL 9-V0 approved, with a working temperature range of -0 C to +5 C. inserts in conformance with the requirements of the EN 698 standard and certified and marked with the UL, CSA, CCC, GL, GOST marks. inserts with asymmetric guide rails to prevent incorrect coupling. position of contacts identified with numbers or codes on both sides of every insert. IXO male/female module carrier frames with mandatory housings and polarity, in die-cast zinc alloy. module lock tab, may be divided according to the number of modules used; guarantees a perfect stability of the modules during wiring and coupling/uncoupling of the connectors. asymmetric earth contacts (two for frame) with wide contact surface to prevent incorrect coupling; when two or more identical connectors of the IXO series are used, coded pins prevent incorrect coupling (see pages 9, 0 and ). captive frame fastening screws, with flexible spring washer. dummy module for unused frame slots. 57

3 IXO modular units for multipole connectors IXO inserts contact signal connectors and rated rated No. of frame type type tubes connections current A voltage V slots CX 0 Y/ main electric crimp CX 0 YPE/ PE --- crimp CX 0 G/ main electric crimp CX 07/ main electric crimp CX 0A/ main electric axial screw CX 0B/ main electric axial screw CX 0/ main electric crimp 0 00/690 CX 0B/B main electric crimp CX / XD/ main electric crimp 0/0 80 CX 0 X/ main electric crimp 0 80 CX 05 S/ main electric spring 6 00 CX 06 C/ main electric crimp CX 08 C/ main electric crimp 6 00 CX 0 C/ main electric crimp CX D/ main / auxiliary electric crimp 0 50 CX 7 D/ main / auxiliary electric crimp 0 60 CX 5 I/ main / auxiliary elettrico crimp 50 CX 0 H/ main electric crimp 6 900/5000 CX 0 B/ seat for two shielded connectors (see CX 0 B, CX 0 B, CX 0 BC, CX 08 B) CX 0 BC/ main / auxiliary + shield electric crimp CX 0 B/ main / auxiliary + shield electric crimp CX 0 B/ main / auxiliary + shield electric crimp CX 08 B/ main / auxiliary + shield electric crimp CX 0 P pneumatic Ø mm gas / liquid ** push-in CX 0 P pneumatic Ø 6.0 mm gas / liquid ** push-in CX none (dummy module) CX 0 J/ RJ5 + auxiliary electric crimp 0 50 CX 0 J/ RJ5 + auxiliary electric crimp 0 50 CX 0 U/ USB electric CX 09V/ D-SUB electric crimp 5 50 CX 0 L/ PO / OST / coaxial optic / electric crimp / solder ** Warning: or obvious reasons of safety, the VDE standard does not permit electric contacts to be present within the same connector group together with contacts for the transmission of liquids. In addition, the use of pneumatic air contacts requires an appropriate filtering and dehydration system to prevent dangerous condensation. Contacts may be used for pressure values of up to a maximum of 8 bar/6 psi. 58

4 main features IXO CX..Y 00A version modular inserts. The IXO series has been enhanced with a new insert, suitable for currents up to 00A and with new, CY series crimp contacts featuring several benefits over conventional screw or axial screw contacts: ore resistant to mechanical stresses such as vibrations, shock and cable loads ore corrosion resistant (gas tight) Quicker to connect and ensuring more consistent results (regardless of the operators force ) The connector is electrically more efficient (reduced voltage drop) This innovative insert design following the same concepts of the IXO 00A CX..G model, patented by ILE, ensures a quicker fitting and removal of crimped contacts. The four provided keys firmly fasten the contact holder and; once the insert is joined to other inserts (and it is installed in the correspondind IXO frame) the connection is totally secure and extremely resistant, even under the most severe stresses such as vibration and shock. The contacts can be removed without any special tool, using a simple screwdriver. The crimping operation can be carried out quickly and efficiently with the CYPZ hand operated hydraulic pliers, which is pre-fitted with the suitable locator. Suitable crimp dies available on request. IXO code inserts (IXO series) No. of poles rated current ) CX..Y main contact auxiliary contacts -- 00A ) Please check the insert load curves to establish the actual maximum operating current according to the ambient temperature. ) Certifications shown in brackets are currently being applied for. rated voltage 000V EN 698 rated impulse 8kV pollution degree withstand voltage pollution degree UL/CSA certification rated voltage (a.c../d.c.) 600V certifications ) contact resistance insulation resistance (cul), (CSA), (CCC), (GL) 0. mω 0 GΩ ambient temperature limit min -0 ( C) max +5 degree of protection with enclosures (according to version) IP65, IP66, IP67, IP68, IP69K conductor connections * conductor cross-section without enclosures IP0 crimp mm 6, 5, 5, 50, 70 AWG 6,,,, /0 stripping lenght mm 5 mechanical endurance (rating cycles) 500 * max external conductor Ø = 6 mm 59

5 IXO modular units pole 00A - 000V frames which are then mounted in traditional housings * or COB panel support modular units, crimp connections 00A crimp contacts heat shrink tube frames for modular units *... page: 95 * enclosures: housings or high construction hoods IXO NEW description part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX 0 Y - male inserts for female contacts CX 0 Y 00A female crimp contacts 6 mm AWG 6 one groove (back side) CYA 6 5 mm AWG with no grooves CYA 5 5 mm AWG one groove CYA 5 50 mm AWG two grooves CYA mm AWG /0 with no grooves CYA 70 00A male crimp contacts 6 mm AWG 6 one groove (back side) CYA 6 5 mm AWG with no grooves CYA 5 5 mm AWG one groove CYA 5 50 mm AWG two grooves CYA mm AWG /0 with no grooves CYA 70 heat shrink tube for CYA/CYA 6 contacts or for conductor with total external Ø < 0 mm CR TT - characteristics according to EN 698: 00A 000V 8kV 00A 90/600V 8kV - certifications: (cul - UL for USA and Canada), (CSA), (CCC), (GL); the certifications shown in brackets are being applied for - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0, mω - for maximum current load, see the following load curves inserts, for more information see page CY andcy 0 ø 0 ø 9.5 ø 0 8 CY and CY contacts conductor conductor conductor section slot stripping lenght (mm ) (mm) (mm) diagramme CX 0 Y - pôle (IXO 00A) mm 70 mm CR TT 50 courant d exercice (A) mm 5 mm heat shrink tube température ambiante ( C) - frame slots YES 90/00 C NO 60

6 IXO modular units PE pole 00A frames which are then mounted in traditional housings * or COB panel support modular units, crimp connections PE module for earth termination 00A crimp contacts frames for modular units *... page: 95 * enclosures: housings or high construction hoods NEW IXO description part No. part No. without contacts (to be ordered separately) - PE female inserts for female contacts CX 0 YPE - PE male inserts for female contacts CX 0 YPE 00A female crimp contacts 6 mm AWG 6 one groove (back side) CYA 6 5 mm AWG with no grooves CYA 5 5 mm AWG one groove CYA 5 50 mm AWG two grooves CYA mm AWG /0 with no grooves CYA 70 00A male crimp contacts 6 mm AWG 6 one groove (back side) CYA 6 5 mm AWG with no grooves CYA 5 5 mm AWG one groove CYA 5 50 mm AWG two grooves CYA mm AWG /0 with no grooves CYA 70 - certifications: (cul - UL for USA and Canada), (CSA), (CCC), (GL); the certifications shown in brackets are being applied for - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 9. CY andcy 0 ø 0 CX 0 YPE ø 9.5 ø CY and CY contacts conductor conductor slot conductor section stripping lenght (mm ) (mm) (mm) frame slots 6

7 main features IXO CX..G 00A version modular inserts. The IXO series has been enhanced with a new insert, suitable for currents up to 00A and with new, CG series crimp contacts featuring several benefits over conventional screw contacts as they are: ore resistant to mechanical stresses such as vibrations and cable loads ore corrosion resistant (gas tight) Quicker to connect and ensuring more consistent results (regardless of the operators force ) The connector is electrically more efficient (reduced voltage drop) This innovative insert design, patented by ILE, ensures a quicker fitting and removal of crimped contacts. IXO The plates provided firmly fasten the contact holder and, once the insert is mated to other inserts and is inserted in the IXO frame, the connection is totally secure and extremely resistant, even to the most severe stresses such as vibrations. The contacts can be removed without having to use any special tools but by simply using a screwdriver. The crimping operation can be carried out quickly and effectively thanks to the CGPZ hydraulically operated pliers provided which, on request, can be supplied with the required locator and dies. 6

8 IXO modular units poles 00A - 000V frames which in turn are installed in traditional housings * or COB panel support modular units, crimp connections 00A crimp contacts, PE adapter frames for modular units *... page: 95 * enclosures: bulkhead mounting housings, high construction housings or high construction hoods IXO description part No. part No. without contacts (to be ordered separately) - female inserts for female contacts ** CX 0 G - male inserts for female contacts ** CX 0 G 00A female crimp contacts 6 mm AWG 6-5 CGA 6 5 mm AWG - CGA 5 5 mm AWG CGA 5 00A male crimp contacts 6 mm AWG 6-5 CGA 6 5 mm AWG - CGA 5 5 mm AWG CGA 5 cable earthing adapter 6 mm (AWG 6-5) CGT 6 ** on request, version with pole / numbering, references: CX 0 GN, CX 0 GN 9. CG and CG CGT 6 ø characteristics according to EN 698: 00A 000V 8kV 00A 90/600V 8kV - certifications: cul (UL for USA and Canada), CCC, GL, GOST - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0. mω - for contact crimping instructions, please see the crimping tool section (00A contacts, CG and CG series) on page 76 - for maximum current load, see the following load curves inserts, for more information see page ø C ø ø working current (A) diagram CX 0 poles (IXO 00A) ø C ø B CG and CG contacts conductor conductor slot conductor section ø B ø C stripping lenght (mm ) (mm) (mm) (mm) (mm) ambient temperature ( C) - footprint modules How to use the PE adapter (CGT 6): ) Strip 5 mm of flexible PE protective cable ) Crimp the cable on the CGT 6 adapter by using the CGPZ pliers with the CGD 6 C matrix ) ix the adapter tip in the larger earth terminal (6 mm ) of frames CX...T/T ) To be used with bulkhead mounting housings or high construction hoods 5) Cannot be used with T-TYPE series 6

9 IXO modular units poles 70A - 000V frames which in turn are installed in traditional housings * or COB panel support modular units, crimp connections 70A crimp contacts frames for modular units *... page: 9-95 * enclosures: bulkhead mounting housings, high construction housings or high construction hoods IXO NEW description part No. part No. NEW without contacts (to be ordered separately) - female inserts for female contacts CX male inserts for female contacts CX A female crimp contacts 0 mm AWG 8-7 CX7A 0 6 mm AWG 6-5 CX7A 6 5 mm AWG - CX7A 5 70A male crimp contacts 0 mm AWG 8-7 CX7A 0 6 mm AWG 6-5 CX7A 6 5 mm AWG - CX7A 5 - characteristics according to EN 698: 70A 000V 8kV 70A 600V kv - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - for contact crimping instructions, please see the crimping tool section (70A contacts, CX7 and CX7 series) on page 7 - C7ES removal tool ø ø ø.5 contacts CX7 and CX7 conductor conductor slot conductor section stripping lenght (mm ) (mm) (mm) footprint module 6

10 IXO modular units poles 0A - 000V frames which in turn are installed in traditional modular units, modular units, screw terminal connection screw terminal connection.5 8 mm 6 0 mm frames for modular units... page: characteristics according to EN 698: 0A 000V 8kV 0A 600V kv - UL, CSA, GOST certified - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0.5 mω IXO description part No. part No. - female inserts with female contacts CX 0 A - male inserts with female contacts CX 0 A - female inserts with female contacts CX 0 B - male inserts with female contacts CX 0 B - for maximum current load, see the following load curves inserts, for more information see page 500 diagramme CX 0 A/B pôles courant d exercice (A) température ambiante ( C) use flexible cables with sections from.5 to 0 mm or extra flexible cables with sections from.5 to 6 mm do not twist the cables fully insert the braids in the rear section of the contact conductor conductor tightening section stripping lenght torque (mm ) (mm) (Nm) insert a mm hexagonal key in the front section of the contact and tighten by keeping the cable held down in position a mm hexagonal key can be supplied on request, reference CX AS - inserts for Ø mm cables, section:.5-8 mm - AWG -8 - footprint module - inserts for Ø.8 mm cables, section: 6-0 mm - AWG footprint module 65

11 main features IXO CX / XD modular connectors IXO CX / XD connectors have the following characteristics: - slots for CX crimped contacts (0A max) for power circuits - slots for CD crimped contacts (0A max) for signal circuits Their key characteristic lies in the fact that they guarantee maximum safety even in case of accidental contact with fingers (IPXXB or IPX). Safety is guaranteed as standard on female contacts, but also on male contacts. This feature is important as it ensures full compliance with the recent safety standard EN 600-, concerning electric equipment fitted on machines and in particular with the requirements of Article 6.. concerning protection against residual voltage. Live parts having a residual voltage greater than 60V after the supply has been disconnected shall be discharged to 60V or less within a time period of 5 s after disconnection of the supply voltage provided that this rate of discharge does not interfere with the proper functioning of the equipment. Exempted from this requirement are components having a stored charge of 60 µc or less. Where this specified rate of discharge would interfere with the proper functioning of the equipment, a durable warning notice drawing attention to the hazard and stating the delay required before the enclosure may be opened shall be displayed at an easily visible location on or immediately adjacent to the enclosure containing the capacitances. In the case of plugs or similar devices, the withdrawal of which results in the exposure of conductors (for example pins), the discharge time shall not exceed s, otherwise such conductors shall be protected against direct contact to at least an IPX or IPXXB. If neither a discharge time of s nor a protection of at least IPX or IPXXB can be achieved (for example in the case of removable collectors on conductor wires, conductors bars, or slip-ring assemblies, see.7.), additional switching devices or an appropriate warning device (for example a warning notice in accordance with 6.) shall be applied. The IPX or IPXXB protection offered by CX / XD modules fitted with CX and CD contacts ensures greater design flexibility as it enables, for example, connectors to be used for drives of electric motors (frequency converters) and in all applications where voltage could be present on both sides of the connector (for example power circuits in loop configuration, opening, circuits of battery-chargers). Thanks to the enhanced insulation, the rated voltage of the module is equivalent to 80V, in compliance with standards EN 698 and EN 6066-, with an impulse withstand voltage of 8 kv for pollution degree even between signal contacts. code inserts (IXO series) No. of poles main contacts auxiliary contacts CX..XD ) Please check the insert load curves to establish the actual maximum operating current according to the ambient temperature. ) Certifications shown in brackets are currently being applied for. rated current ) main contacts 0A auxiliary contacts 0A rated voltage 80V EN 698 rated impulse 8kV pollution degree withstand voltage pollution degree UL/CSA certification rated voltage (a.c../d.c.) 600V certifications ) (cul), (CSA), (CCC), (GL) contact resistance insulation resistance main contacts auxiliary contacts 0. mω mω 0 GΩ ambient temperature limit min -0 ( C) max +5 degree of protection with enclosures IP65, IP66, IP67, IP68, IP69K (according to type) conductor connections conductor cross-section main contacts conductor cross-section auxiliary contacts without enclosures IP0, also on male contacts crimp mm.5 6 AWG 6 0 mm 0..5 AWG 6 stripping lenght mm 9 (.5.5 mm ) main contacts 9.6 ( 6 mm ) stripping lenght mm 8 (0..5 mm ) auxiliary contacts 6 (.5 mm ) mechanical endurance (rating cycles)

12 IXO modular units poles (0A - 80V) + poles (0A - 80V) frames which are then mounted in traditional frames for modular units... page: 9-95 modular units, crimp connections 0A and 0A crimp contacts silver and gold plated 0A - male and female contacts to test of contact with fingers - for contact crimping, see the crimp tool section (0A contacts CX, CX series and 0A contacts CD, CD series) on pages 66, 68, 70, 80, 8, 8, 86 NEW 0A IXO description part No. part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX / XD - male inserts for male contacts CX / XD 0A female crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA 6.0 0A male crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA 6.0 0A female contacts mm AWG 6- identification No. CDA 0. CDD mm AWG 0 identification No. CDA 0.5 CDD mm AWG 8 identification No. CDA 0.7 CDD 0.7 mm AWG 8 identification No. CDA.0 CDD.0.5 mm AWG 6 identification No. CDA.5 CDD.5.5 mm AWG identification No. 5 CDA.5 CDD.5 0A male contacts mm AWG 6- identification No. CDA 0. CDD mm AWG 0 identification No. CDA 0.5 CDD mm AWG 8 identification No. CDA 0.7 CDD 0.7 mm AWG 8 identification No. CDA.0 CDD.0.5 mm AWG 6 identification No. CDA.5 CDD.5.5 mm AWG identification No. 5 CDA.5 CDD.5 - characteristics according to EN 698: poles0a 80V 8kV poles0a 80V 8kV - certifications: (cul - UL for USA and Canada), (CSA), (CCC), (GL); the certifications shown in brackets are being applied for - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0. mω ( poles) mω ( poles) - for maximum current load, see the following load curves inserts, for more information see page 500 working current (A) diagram CX / poles ,0 mm 6,0 mm ambient temperature ( C) - frame slot.7. 9 B 9 ø B.5 CX and CX CD and CD ø 6 ø. ø 6 ø.5 B 5 ø.6 B.6 gold plated CD and CD contacts conductor conductor conductors section mm slot (mm) stripping length B (mm) CX and CX contacts conductor conductor conductors section mm slot (mm) stripping length B (mm)

13 IXO modular units poles 0A - 00/690V frames which in turn are installed in traditional modular units, crimp connections 0A crimp contacts frames for modular units... page: 9-95 IXO description part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX 0 * - male inserts for male contacts CX 0 * 0A female crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA 6.0 0A male crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA 6.0 * cable diameter up to 5 mm - characteristics according to EN 698: 0A 00/690V 6kV - UL, CSA, GOST certified - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0. mω - for contact crimping instructions, please see the crimping tool section (0A contacts, CX and CX series) on pages 68, 70 and 86 - for maximum current load, see the following load curves inserts, for more information see page ø 6 B 9. ø.5 diagram CX 0 poles 50 B ø 6 0,0 mm working current (A) ,5 mm 6,0 mm CX and CX contacts conductor conductor conductors section slot stripping length mm (mm) B (mm) ambient temperature ( C) - footprint module 68

14 IXO modular units poles 0A - 500V frames which in turn are installed in traditional modular units, crimp connections 0A crimp contacts frames for modular units... page: 9-95 NEW description part No. part No. IXO without contacts (to be ordered separately) - female inserts for female contacts CX 0 B * - male inserts for male contacts CX 0 B * 0A female crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA mm AWG 8 CXA 0 0A male crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA mm AWG 8 CXA 0 * cable diameter up to mm contact section up to 0 mm.7 ø 6 - characteristics according to EN 698: 0A 500V 6kV - certifications: (UL), (CSA), (GOST); the certifications shown in brackets are being applied for - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0. mω - for contact crimping instructions (.5 0 mm ), please see the crimping tool section (0A contacts, CX and CX series) on pages 68, 70 and 86 - for maximum current load, see the following load curves inserts, for more information see page B 9. ø.5 B ø 6 diagram CX 0 B poles 50 working current (A) ,5 mm,0 mm 6,0 mm 0 mm CX and CX contacts conductor conductor conductors section slot stripping length mm (mm) B (mm) ambient temperature ( C) - footprint module 69

15 main features IXO CX X modular connectors The new CX 0 X inserts have the same dimensions of CX 0 / inserts, but have seats for crimp contacts series CX (0A max) used in power circuits. Thanks to the enhanced insulation, the rated voltage of the module is equivalent to 80V, in compliance with standards EN 698 and EN 6066-, with an impulse withstand voltage of 8 kv for pollution degree even between signal contacts.. Their key characteristic lies in the fact that they guarantee maximum safety even in case of accidental contact with fingers (IPXXB or IPX). Safety is guaranteed as standard on female contacts, but also on male contacts. This feature is important as it ensures full compliance with the recent safety standard EN 600-, concerning electric equipment fitted on machines and in particular with the requirements of Article 6.. concerning protection against residual voltage: IXO Live parts having a residual voltage greater than 60V after the supply has been disconnected shall be discharged to 60V or less within a time period of 5 s after disconnection of the supply voltage provided that this rate of discharge does not interfere with the proper functioning of the equipment. Exempted from this requirement are components having a stored charge of 60 µc or less. Where this specified rate of discharge would interfere with the proper functioning of the equipment, a durable warning notice drawing attention to the hazard and stating the delay required before the enclosure may be opened shall be displayed at an easily visible location on or immediately adjacent to the enclosure containing the capacitances. In the case of plugs or similar devices, the withdrawal of which results in the exposure of conductors (for example pins), the discharge time shall not exceed s, otherwise such conductors shall be protected against direct contact to at least an IPX or IPXXB. If neither a discharge time of s nor a protection of at least IPX or IPXXB can be achieved (for example in the case of removable collectors on conductor wires, conductors bars, or slip-ring assemblies, see.7.), additional switching devices or an appropriate warning device (for example a warning notice in accordance with 6.) shall be applied. The IPX or IPXXB protection offered by CX 0 X modules fitted with CX contacts ensures greater design flexibility as it enables, for example, connectors to be used for drives of electric motors (frequency converters) and in all applications where voltage could be present on both sides of the connector (for example power circuits in loop configuration, opening, circuits of battery-chargers). NOTE emale inserts are supplied with two red lock tabs that must be used to assemble the inserts on the frame instead of the grey ones supplied with the frame. code inserts (IXO series) No. of poles main contacts CX..X ) Please check the insert load curves to establish the actual maximum operating current according to the ambient temperature. ) Certifications shown in brackets are currently being applied for. rated current ) 0A rated voltage 80V EN 698 rated impulse 8kV pollution degree withstand voltage pollution degree UL/CSA certification rated voltage (a.c../d.c.) 600V certifications ) (cul), (CSA), (CCC), (GL) contact resistance insulated resistance 0, mω 0 GΩ ambient temperature min -0 limit ( C) max +5 degree of protection with enclosures IP65, IP66, IP67, IP68, IP69K (according to type) conductor connections without enclosures IP0 also on male contacts crimp conductor cross-section mm.5 6 main contacts stripping lenght mm 9 (.5.5 mm ) main contacts 9.6 ( 6 mm ) mechanical endurance (rating cycles)

16 IXO modular units poles 0A - 80V frames which are then mounted in traditional modular units, crimp connections 0A crimp contacts frames for modular units... page: 9-95 NEW IXO description part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX 0 X - male inserts for male contacts CX 0 X 0A female crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA 6.0 0A male crimp contacts.5 mm AWG 6 CXA.5.5 mm AWG CXA.5 mm AWG CXA.0 6 mm AWG 0 CXA characteristics according to EN 698: 0A 80V 8kV 0A 000V 8kV - certifications: cul (UL for USA and Canada), (CSA), (CCC), (GL); the certifications shown in brackets are being applied for - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: 0. mω - for contact crimping instructions, please see the crimping tool section (0A contacts, CX and CX series) on pages 68, 70 and 86 - male and female contacts to test of contact with fingers - for maximum current load, see the following load curves inserts, for more information see page ø 6 B 9. ø.5 B working current (A) diagram CX 0 poles ,0 mm 5 6,0 mm - frame slot ø 6 CX and CX contacts conductor conductor conductor section slot stripping lenght mm (mm) B (mm) ambient temperature ( C) emale inserts are supplied with two red lock tabs that must be used instead of those supplied with the frames. 7

17 IXO modular units 6 poles 6A - 500V frames which in turn are installed in traditional modular units, crimp connections 6A crimp contacts normal or for advanced opening silver and gold plated frames for modular units... page: 9-95 description part No. part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX 06 C - male inserts for female contacts CX 06 C 6A female contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 gold plated IXO 6A male contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 6A male crimp contacts for advanced opening 0.5 mm AWG 0 with no grooves CC 0.5 AN 0.75 mm AWG 8 one groove (back side) CC 0.7 AN mm AWG 8 one groove CC.0 AN.5 mm AWG 6 two grooves CC.5 AN.5 mm AWG three grooves CC.5 AN - characteristics according to EN 698: 6A 500V 6kV 6A 00/690V 6kV - UL, CSA, CCC, GL, GOST certified - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - for contact crimping instructions, please see the crimping tool section (6A contacts, CC, CC and CC...AN series) on pages 66, 70, 80, 8, 8, 86 - for maximum current load, see the following load curves inserts, for more information see page CC and CC ø.5 ø.5 5 CC...AN ø.5 ø.5.8 diagram CX 06 poles 0 6. working current (A) ,5 mm,5 mm,0 mm ambient temperature ( C) - footprint module ø.5 CC, CC and CC..AN contacts conductor conductor conductors section slot stripping length mm (mm) (mm)

18 IXO modular units 8 poles 6A - 00V frames which in turn are installed in traditional modular units, crimp connections 6A crimp contacts normal or for advanced opening silver and gold plated frames for modular units... page: 9-95 IXO description part No. part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX 08 C - male inserts for female contacts CX 08 C 6A female contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 gold plated 6A male contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 6A male crimp contacts for advanced opening 0.5 mm AWG 0 with no grooves CC 0.5 AN 0.75 mm AWG 8 one groove (back side) CC 0.7 AN mm AWG 8 one groove CC.0 AN.5 mm AWG 6 two grooves CC.5 AN.5 mm AWG three grooves CC.5 AN - characteristics according to EN 698: 6A 00V 6kV 6A 00/690V 6kV - UL, CSA, CCC, GOST certified - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - for contact crimping instructions, please see the crimping tool section (6A contacts, CC, CC and CC...AN series) on pages 66, 70, 80, 8, 8, 86 - for maximum current load, see the following load curves inserts, for more information see page CC and CC ø.5 ø.5 5 CC...AN ø.5 ø.5.8 diagram CX 08 poles 6. working current (A) ,5 mm,5 mm ambient temperature ( C) - footprint module ø.5 CC, CC and CC..AN contacts conductor conductor conductors section slot stripping length mm (mm) (mm)

19 IXO modular units 0 poles 6A - 500V frames which in turn are installed in traditional modular units, crimp connections 6A crimp contacts normal or for advanced opening silver and gold plated frames for modular units... page: 95 IXO * on request, version with fastened CX 0 C/C inserts with poles numbered from 60 references: CX 60 C, CX 60 C description part No. part No. part No. without contacts (to be ordered separately) - female inserts for female contacts * CX 0 C - male inserts for female contacts * CX 0 C 6A female contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 gold plated 6A male contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 6A male crimp contacts for advanced opening 0.5 mm AWG 0 with no grooves CC 0.5 AN 0.75 mm AWG 8 one groove (back side) CC 0.7 AN mm AWG 8 one groove CC.0 AN.5 mm AWG 6 two grooves CC.5 AN.5 mm AWG three grooves CC.5 AN - characteristics according to EN 698: 6A 500V 6kV 6A 80V 8kV - certifications: cul (UL for USA and Canada), CSA, GOST - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - for contact crimping instructions, please see the crimping tool section (6A contacts, CC, CC and CC...AN series) on pages 66, 70, 80, 8, 8, 86 - for maximum current load, see the following load curves inserts, for more information see page diagram CX 0 poles 9, 8 0 CC and CC ø.5 ø.5 5. CC...AN ø.5 ø.5.8 working current (A) ,5 mm,5 mm,0 mm ambient temperature ( C) - footprint modules ø.5 CC, CC and CC..AN contacts conductor conductor conductors section slot stripping length mm (mm) (mm)

20 IXO modular units 5 poles 6A - 00V frames which in turn are installed in traditional modular units, spring connection frames for modular units... page: 9-95 IXO description part No. - female inserts with female contacts CX 05 S - male inserts with male contacts CX 05 S - characteristics according to EN 698: 6A 00V 6kV 6A 500V 6kV - UL, CSA, CCC, GL, GOST certified - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - for maximum current load, see the following load curves inserts, for more information see page diagram CX 05 poles ,5 mm working current (A) 0 8 6,5 mm ambient temperature ( C) - inserts for section conductors: mm - AWG conductors stripping lenght: 9... mm - footprint module connection with spring terminal.5x0,5 mm 75

21 IXO modular units HT poles 6A - 900/5000V frames which in turn are installed in traditional housings * or COB panel support frames for modular units *... page: 95 * enclosures: bulkhead mounting housings, high construction housings or high construction hoods high voltage modular units, crimp connections contact holder removal tool 6A crimp contacts silver and gold plated IXO - characteristics according to EN 698 **: 6A 900/5000V 5kV ** used for guidance as applicable - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - for contact crimping, see the crimp tool section (6A CC and CC series contacts) on pages 66, 70, 80, 8, 8, 86 description part No. part No. part No. without contacts (to be ordered separately) - female inserts high voltage for female contacts CX 0 H - male inserts high voltage for male contacts CX 0 H contact holder removal tool CHES 6A female contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 gold plated 6A male contacts mm AWG 6- three grooves CCA 0. CCD mm AWG 0 with no grooves CCA 0.5 CCD mm AWG 8 one groove (back side) CCA 0.7 CCD 0.7 mm AWG 8 one groove CCA.0 CCD.0.5 mm AWG 6 two grooves CCA.5 CCD.5.5 mm AWG three grooves CCA.5 CCD.5 mm AWG one wide groove CCA.0 CCD.0 mm AWG with no grooves CCA.0 CCD.0 How to use the IXO HT module Wiring and assembly: ) Strip the wire by 9.5 mm length and insert it into the contact holder CC CC CONTACT HOLDER 9,5 ) Crimp series CC contact (6A max) on the stripped wire CRIP 9. 6 ø.5 ø.5 5 ) Insert the contact holder into the module. 8 max 7 ø.5 Heat shrinking tubes to be applied on the rear side of the module and over the contact holder are furnished together with the product Removal: ) Remove the contact holder by means of the proper tool CHES CABLE CHES - footprint modules CC and CC contacts conductor conductor conductors section slot stripping length mm (mm) (mm)

22 IXO modular units poles 0A - 50V frames which in turn are installed in traditional modular units, crimp connections 0A crimp contacts silver and gold plated frames for modular units... page: 9-95 IXO description part No. part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX D - male inserts for female contacts CX D 0A female crimp contacts mm AWG 6- CDA 0. CDD mm AWG 0 CDA 0.5 CDD mm AWG 8 CDA 0.7 CDD 0.7 mm AWG 8 CDA.0 CDD.0.5 mm AWG 6 CDA.5 CDD.5.5 mm AWG CDA.5 CDD.5 0A male crimp contacts mm AWG 6- CDA 0. CDD mm AWG 0 CDA 0.5 CDD mm AWG 8 CDA 0.7 CDD 0.7 mm AWG 8 CDA.0 CDD.0.5 mm AWG 6 CDA.5 CDD.5.5 mm AWG CDA.5 CDD.5 - characteristics according to EN 698: 0A 60V,5kV 0A 50V kv - UL, CSA, CCC, GL, GOST certified - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - PCBs interface, see article CI. - for contact crimping, see the crimp tool section (0A contacts, CD and CD series) on pages 66, 70, 80, 8, 8, 86 - for maximum current load, see the following load curves inserts, for more information see page B ø.6 B ø. 5.6 gold plated 5 diagram CX poles ø.5 working current (A),5 mm ,0 mm footprint module CD and CD contacts conductor conductor conductors section slot stripping length mm (mm) B (mm) ambient temperature ( C) 77

23 IXO modular units 7 poles 0A - 60V frames which are then mounted in traditional modular units, crimp connections 0A crimp contacts silver and gold plated frames for modular units... page: 9-95 IXO NEW description part No. part No. part No. without contacts (to be ordered separately) - female inserts for female contacts CX 7 D - male inserts for male contacts CX 7 D 0A female contacts mm AWG 6- identification No. CDA 0. CDD mm AWG 0 identification No. CDA 0.5 CDD mm AWG 8 identification No. CDA 0.7 CDD 0.7 mm AWG 8 identification No. CDA.0 CDD.0.5 mm AWG 6 identification No. CDA.5 CDD.5.5 mm AWG identification No. 5 CDA.5 CDD.5 0A male contacts mm AWG 6- identification No. CDA 0. CDD mm AWG 0 identification No. CDA 0.5 CDD mm AWG 8 identification No. CDA 0.7 CDD 0.7 mm AWG 8 identification No. CDA.0 CDD.0.5 mm AWG 6 identification No. CDA.5 CDD.5.5 mm AWG identification No. 5 CDA.5 CDD.5 - characteristics according to EN 698: 0A 60V,5kV 0A 50V kv - certifications: (UL), (CSA), (CCC); the certifications shown in brackets are being applied for - rated voltage according to UL/CSA: 600V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω - for contact crimping, see the crimp tool section (0A contacts, CD and CD series) on pages 66, 70, 80, 8, 8, 86 - for maximum current load, see the following load curves inserts, for more information see page diagram CX 7 poles B ø.6 B ø. 5.6 ø.5 gold plated working current (A) 0,5 mm ,0 mm CD and CD contacts conductor conductor conductors section slot stripping length mm (mm) B (mm) ambient temperature ( C) - frame slot 78

24 IXO modular units 5 poles A - 50V frames which are then mounted in traditional modular units, crimp connections crimp contacts gold plated frames for modular units... page: we recommend the use of CR / CR code pins NEW description part No. part No. IXO without contacts (to be ordered separately) - female inserts for female contacts CX 5 I - male inserts for male contacts CX 5 I A female crimp contacts mm AWG 8- CID mm AWG 6- CID mm AWG -0 CID 0.5 A male crimp contacts mm AWG 8- CID mm AWG 6- CID mm AWG -0 CID characteristics according to EN 698: A 50V 0.8kV A 60V.5kV - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C - are made of self-extinguishing thermoplastic resin UL 9 V0 - for crimp contacts CI series using: CIPZ D crimping tool CITP D turret head CIES insertion / removal tool.7.7 gold plated ø.66 ø ø CI, CI contacts conductor conductor conductors section slot stripping length mm (mm) (mm) frame slot 79

25 IXO modular units or poles + shield (each connector) 0A - 50V frames which in turn are installed in traditional seat for shielded connectors metal adaptor shielded connectors 0A crimp contacts, silver or gold plated frames for modular units... page: 95 - characteristics according to EN 698: description part No. seat for two shielded connectors - female insert, two seats for BUS connectors - male insert, two seats for BUS connectors CX 0 B CX 0 B part No. part No. shielded BUS multi axial connectors, poles + shield - female insert, four contact seats + shield - male insert, four contact seats + shield CX 0 B CX 0 B shielded BUS coaxial connectors, pole + shield - female insert, one contact seats + shield - male insert, one contact seats + shield CX 0 B CX 0 B 0A female crimp contacts mm AWG mm AWG mm AWG 8 mm AWG 8.5 mm AWG 6.5 mm AWG CDA 0. CDA 0.5 CDA 0.7 CDA.0 CDA.5 CDA.5 0A male crimp mm 0.5 mm 0.75 mm mm.5 mm.5 mm CDA 0. CDA 0.5 CDA 0.7 CDA.0 CDA.5 CDA.5 contacts AWG 6- AWG 0 AWG 8 AWG 8 AWG 6 AWG Note: The shielded connectors have their shield insulated from the enclosure s earthing point. If you wish to earth-connect the shield, install on the panel an anchorage for shielded cables CR..ST (see page 5) or the CR GND metal adaptor.. CX 0 B, CX 0 B CDD CDD CDD CDD CDD CDD CDD CDD CDD CDD CDD CDD gold plated CR GND metal adaptor (optional) IXO 0A 50V 0,8kV - UL, CSA, CCC (no CX 0 B), GOST certified - rated voltage according to UL/CSA: 50V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C (CX 0 B and CX 0 B) - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω (no CX 0 B) - coaxial connector CX 0 B cables with a typical impedance of 75 Ω (atténuation see page 50) - CX 0 B multiaxial connector for STP cables with pairs and terminations compliant with EN 507- Cat. 5 (00 Hz), compatible with -wire field bus protocols - extraction tool for BUS shielded connectors from IXO BUS insert part No. CX BES see page 0 CX 0 B, CX 0 B Use of the CR GND metal adaptor 6 cable clamps included in the package Ø 5.5 Ø 5.5 CX 0 B, CX 0 B 6, b Ø 5.5 Ø conductors stripping length see page 78 - crimp contacts dimensions (CD and CD) see page 78 - for contact crimping, see the crimp tool section (0A contacts, CD and CD series) on pages 66, 70, 80, 8, 8, 86 - footprint modules CR GND 6 cable clamps included in the package 6

26 IXO modular units 8 poles + shield (each connector) 5A - 50V frames which are then mounted in traditional seat for shielded connectors metal adaptor shielded connectors 5A crimp contacts, gold plated frames for modular units... page: 95 - characteristics according to EN 698: 5A 50V 0,8kV W NE description part No. seat for two shielded connectors - female insert, two seats for BUS connectors - male insert, two seats for BUS connectors CX 0 B CX 0 B part No. shielded BUS multi axial connectors, 8 poles + shield - female insert, eight contact seats + shield - male insert, eight contact seats + shield metal adaptor (optional) CX 08 B CX 08 B CR GND contacts AWG -8 AWG 6 0 AWG 0- CID 0. CID 0. CID 0.5 5A male crimp contacts mm AWG mm AWG mm AWG 0- CID 0. CID 0. CID 0.5 Note: The shielded connectors have their shield insulated from the enclosure s earthing point. If you wish to earth-connect the shield, install on the panel an anchorage for shielded cables CR..ST (see page 5) or the CR GND metal adaptor. CX 0 B, CX 0 B gold plated 5A female crimp mm mm mm IXO - UL, CSA, CCC, GOST certified - rated voltage according to UL/CSA: 50V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C (CX 08 B) - are made of self-extinguishing thermoplastic resin UL 9 V0 - maximum Ø of the insulator:. mm - for crimp 5A contacts CI series using: CIPZ D crimping tool CITP D turret head CIES insertion / removal tool - extraction tool for BUS shielded connectors from IXO BUS insert part No. CX BES see page 0 CX 08 B, CX 08 B cable clamps included in the package Use of the CR GND metal adaptor CI, CI contacts conductor conductor section slot ø.66 mm 0,08-0, 0,-0, 0,-0,5.8 ø Ø 5.5 CI and CI øa Ø 5.5 (mm) 0,6 0,90, conductors stripping length (mm). - frame slots b ø.66 øa CR GND.6 9 8

27 IXO modular units pole + shield (each connector) 6A - 50V frames which are then mounted in traditional seat for shielded connectors metal adaptor shielded connectors 6A crimp contacts, silver or gold plated frames for modular units... page: 95 - characteristics according to EN 698: W NE description part No. seat for two shielded connectors - female insert, two seats for BUS connectors - male insert, two seats for BUS connectors CX 0 B CX 0 B part No. shielded BUS coaxial connectors, pole + shield - female insert, one contact seats + shield - male insert, one contact seats + shield metal adaptor (optional) part No. CX 0 BC CX 0 BC 6A female contacts mm AWG 0.5 mm AWG 0.75 mm AWG mm AWG.5 mm AWG.5 mm AWG mm AWG mm AWG three grooves with no grooves one groove (back side) one groove two grooves three grooves one wide groove with no grooves CCA 0. CCA 0.5 CCA 0.7 CCA.0 CCA.5 CCA.5 CCA.0 CCA.0 6A male contacts mm AWG AWG 0.5 mm 0.75 mm AWG mm AWG.5 mm AWG.5 mm AWG mm AWG mm AWG three grooves with no grooves one groove (back side) one groove two grooves three grooves one wide groove with no grooves CCA 0. CCA 0.5 CCA 0.7 CCA.0 CCA.5 CCA.5 CCA.0 CCA.0 Note: The shielded connectors have their shield insulated from the enclosure s earthing point. If you wish to earth-connect the shield, install on the panel an anchorage for shielded cables CR..ST (see page 5) or the CR GND metal adaptor. CX 0 B, CX 0 B CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD gold plated CR GND IXO 6A 50V 0,8kV - UL, CSA, CCC, GOST certified - rated voltage according to UL/CSA: 50V - insulation resistance: 0 GΩ - ambient temperature limit: -0 C C (CX 0 BC) - are made of self-extinguishing thermoplastic resin UL 9 V0 - contact resistance: mω (no CX 0 B) - CX 0 BC shielded connector for cable with a typical impedance of 50 Ω (atténuation see page 50) - for contact crimping instructions, please see the crimping tool section (6A contacts, CC and CC series) on pages 66, 70, 80, 8, 8, 86 - extraction tool for BUS shielded connectors from IXO BUS insert part No. CX BES see page 0 CX 0 BC, CX 0 BC Use of the CR GND metal adaptor cable clamps included in the package Ø 5.5 Ø 5.5 CC and CC øa ø.5 5 ø.5 CC and CC contacts conductor conductor section slot mm (mm) conductors stripping length (mm). - frame slots.6 CR GND b 8 9 ø.5 øa 7,5 7

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

COB panel supports for multipole connectors

COB panel supports for multipole connectors TCQ + TSFS (...CMS, alternative) CMS TSFS Use The system makes it possible to use multipole connectors within electric panels without the traditional metallic housing as protection is assured by the electric

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

gesis IP + Heavy Duty Class I, Zone 2

gesis IP + Heavy Duty Class I, Zone 2 gesis IP + Heavy Duty gesis IP+ 20i HD Z2 Heavy-Duty Connectors for Class 1, Zone 2 Hazardous Locations Catalog 2012 Catch the Next Wave in Modular Connections Plug & Go Heavy-Duty Connectors for areas

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

High Power Connectors for Power Supply and Power Circuits

High Power Connectors for Power Supply and Power Circuits Introduction Silver Plated Power Contacts with Contact Springs for Maximum Performance in Exposed Applications The demand for shortest possible periods of machine shut-downs and assembly times requires

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

7000 Series Buccaneer

7000 Series Buccaneer The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Glenair Military and Industrial Power and Signal Connectors

Glenair Military and Industrial Power and Signal Connectors Glenair Military and Industrial Power and Signal Connectors Series ITS (And FRITS) 5015 Type Reverse Bayonet Connectors Derived from MIL-DTL-5015 and VG95234 Mating mechanism (3 reverse bayonets at 120

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )

More information

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Industrial circular connectors

Industrial circular connectors Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors

More information

CONEC SnapLock. 1 Introduction

CONEC SnapLock. 1 Introduction CONEC SnapLock E L E C T R O N I C C O N N E C T O R S 1 Introduction The new CONEC SnapLock locking system consists of D-SUB connectors and D-SUB hoods allowing quick and safe locking without any additional

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

AC SERIES DUAL 1/4 (6.35mm) / XLR

AC SERIES DUAL 1/4 (6.35mm) / XLR AC SERIES DUAL 1/4 (6.35mm) / XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 ) phone jack

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4 This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

EPIC CIRCON M23 Series Circular Signal Connectors

EPIC CIRCON M23 Series Circular Signal Connectors Circular Signal Connectors CIRCON M2 circular signal connectors are designed to DIN specification N698 and have a standard M2 threaded connection housing. They are offered in coupler, connector, and panel

More information

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

U-shaped Micro Photoelectric Sensor

U-shaped Micro Photoelectric Sensor SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

SMA Connectors. RF Coax Connectors. Product Facts

SMA Connectors. RF Coax Connectors. Product Facts SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes

More information

HARTING Selection Guide Han-Modular Connectors

HARTING Selection Guide Han-Modular Connectors HARTING Selection Guide Han-Modular Connectors Han-Modular Connectors Description of the Han-Modular system The Han-Modular series is designed for combining different transmission media in one connector.

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920 Extract from the online catalog PC 4/ 4-ST-7,62 Order No.: 1804920 The figure shows a 5-pos. version of the product Plug component, nominal current:, rated voltage: 400 V, pitch: 7.62 mm, no. of positions:

More information

Waterproof Connectors for Outdoor Use

Waterproof Connectors for Outdoor Use Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver

More information

DLP-PU/E Instruction Manual

DLP-PU/E Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

SOURIAU s discrete wire sealing

SOURIAU s discrete wire sealing SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Assembly Instruction CAI- Connector with universal Endbell

Assembly Instruction CAI- Connector with universal Endbell CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

CABLE SPECIFICATION CAN CAB RJ45-SUBD9 CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

ZS10 Screw Clamp Terminal Block

ZS10 Screw Clamp Terminal Block Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Fakra. Coaxial connectors. DC 6 GHz

Fakra. Coaxial connectors. DC 6 GHz C-Blue D-Bordeaux GPS application GSM/Mobil Phone The FAKRA (Automobile Expert Group) has therefore defined a standardised connector system for the various communication applications in cars. Our FAKRA-compliant

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization

More information

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS25 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD

More information

System pro M compact Miniature Circuit Breaker S 200/S 200 M

System pro M compact Miniature Circuit Breaker S 200/S 200 M Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art

More information

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation! 4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~

More information